Xerox VersaLink B7025 / B7030 / B7035. Service Manual

Always start with the Service Call Procedures, Section 1. Perform Initial Actions and verify the problem, then follow the directions given.
When a procedure, parts list description or other reference is unique across different speeds of machine, the appropriate speed will be quoted. For example, 25ppm or 35ppm. Any artwork will also be specific.

Download Service Manual

Теги: xerox, versalink, b7035, b7030, b7025, 7035, 7030, 7025

  1. Manuals
  2. Brands
  3. Xerox Manuals
  4. All in One Printer
  5. VersaLink B7030

Manuals and User Guides for Xerox VersaLink B7030. We have 10 Xerox VersaLink B7030 manuals available for free PDF download: Service Manual, User Manual, Security Manual, Security Function Supplementary Manual, Quick Use Manual, Manual, Maintenance, Quick Start Manual

010-331, 010-333 Over Temperature Fail RAP

BSD-ON: BSD 10.2 Fusing Heat Control (1 of 2)

010-331 Fuser thermistor detected temperature monitor AD value that is the specified value or more 10 consecutive times.
010-333 Fuser NC sensor detected a temperature that is the specified value or more 10 consecutive times.

Initial Actions

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

• Remove the fuser. Check whether foreign substances or paper is wound around the heat roll.
• Ensure J416 on the drive PWB is securely connected.

Procedure

Perform the steps that follow:

1. Install new components as necessary:

• LVPS, PL 1.10 Item 3.
• Fuser, PL 10.05 Item 2.
• Drive PWB, PL 1.10 Item 4.
• ESS PWB, PL 3.10 Item 6.

2. To clear this fault, first remove the cause, then reset the value of NVM location 744-002 (Error Detection Flag) to 0. Switch off, then switch on the machine, GP 10.

NOTE: The relationship between the displayed value and the sensor that detected the high temperature error is as follows:

• 0: Normal.
• 1: High temperature error of heat roll nc sensor.
• 2: High temperature error of heat roll thermistor.
• 3: Abnormal temperature increase of heat roll NC sensor, heat roll thermistor.
• 4: Hardware high temperature error of heat roll thermistor.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Содержание

  1. Error 077 901 xerox
  2. How to Fix 077-104 077-109 077-113 077-901 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?
  3. Error 077 901 xerox
  4. Error 077 901 xerox
  5. Error 077 901 xerox

Error 077 901 xerox

КОНФЕРЕНЦИЯ СТАРТКОПИ
Принтеры, копировальные аппараты, МФУ, факсы и другая офисная техника:
вопросы ремонта, обслуживания, заправки, выбора

0. Artresan 10.11.15 10:31

Есть пару таких принтеров, пробеги у всех примерно одинаковые в районе 10-12тыс. проблема у всех одинаковая, в логе одни и те же ошибки 075-100, 077-901, датчик уже чистил. что с ним не так, неужели умирают и из-за этого постоянный глюк?

1. Владимир А. 10.11.15 10:51

Artresan (0): датчик уже чистил
Датчик регистрации?

Бумажку хоть аппаратик забирает?
Ролик подачи крутится?

2. Artresan 10.11.15 11:07

да, датчик регистрации, бумагу захватывает, ролик крутится исправно

Artresan (0): проблема у всех одинаковая
Какая именно (в чем проявляется)?
Artresan (0): в логе одни и те же ошибки
А давно ли (по счетчику пробега) были эти ошибки? Может, больше тыщи страниц тому назад?

4. Artresan 10.11.15 11:13

проявляется в том что либо просто загорается ошибка, либо лист застревает в принтере едва показавшись из фьюзера, сколько тыщ. не скажу в логе только числа стоят и номера ошибок

Artresan (4): в логе только числа стоят
О них и был вопрос.
Artresan (4): либо просто загорается ошибка
Без печати, при простое?
Artresan (4): лист застревает в принтере едва показавшись из фьюзера
Задняя кромка листа при этом находится ГДЕ относительно активатора датчика регистрации?

6. Artresan 10.11.15 11:24

проявляется при печати, задняя кромка еще не проходит датчик. а а сработка через день, два, в день по несколько раз

7. Владимир А. 10.11.15 11:45

Artresan (4): либо лист застревает в принтере едва показавшись из фьюзера,

Изображение на этом застрявшем листе нормальное(не сдвинуто, и т.п.)

Artresan (6): задняя кромка еще не проходит датчик
Сколько остается до активатора?

9. Artresan 10.11.15 12:31

(7)нет не сдигает.
(8) такие замеры точные я уже не производил, передняя кромка едва показывается из фьюзера

Artresan (9): такие замеры точные я уже не производил
И очень зря. Точности там достаточно +/- полсантиметра.

Источник

How to Fix 077-104 077-109 077-113 077-901 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on Nov 25, 2019

077-104, 109, 113, 901 Fuser Exit Sensor Jam RAP

BSD-ON: BSD 10.3 Fusing

077-104 The trail edge of the paper deactuated the fuser exit sensor earlier than the specified time.
077-109 The fuser exit sensor did not actuate within the specified time after the registration clutch energized.
077-113 The trail edge of the paper deactuated the fuser exit sensor later than the specified time.
077-901 The fuser exit sensor detected remaining paper.

Initial Actions

• Check the condition of the paper in all trays. Refer to GP 15 Paper and Media Size Specifications
• Ensure that the fuser is installed correctly.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

WARNING: Do not touch the fuser while it is hot.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.

Perform the steps that follow:

1. Check for obstructions in the paper path.
2. Check the exit 2 roll and nip rolls, PL 10.22 for foreign substances or wear. Clean or install new components as necessary.
3. Remove the fuser. Check whether foreign substances or paper is wound around the heat roll.
4. Enter dC330, code 077-101. Check the fuser exit sensor, part of the fuser, PL 10.05 Item 2.
5. Enter dC330, code 042-003. Check the main motor, PL 40.10 Item 10.
6. Enter dC330, code 077-014. Check the exit 2 motor, PL 10.21 Item 4.
7. Enter dC330, code 077-002. Check the registration clutch, PL 80.55 Item 11.
8. Check the exit 2 drive gears, PL 10.21 for wear or damage.
9. Check the registration transport assembly, PL 80.55 Item 1 for wear or damage.
10. If the fault persists, install new components as necessary:

• Drive PWB, PL 1.10 Item 4.
• ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

Toner Chip (For South America and East Europe Region):

Toner Chip (For Metered Machine):

Источник

Error 077 901 xerox

I have a problem with my new Workcentre 6015. When I turn on the machine always show this message «Paper Jam 077-901 open the rear door and remove the paper», but there is no paper!

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

I pull up the printer top and turn on the power button. So the magic happens, normal initialization without any error message.

I hope this information could be helpful to others.

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

I have got the same problem of paper jam , hv opened the cover [A] search for the paper and no paper , blow atill no solution . Any assistance please

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Hi Irengej,
Thank you for using the Xerox forum.

I would suggest that you review the following site for a possible solution.
WorkCentre 5325/5330/5335 Support & Drivers

There are many tips for specific jammed paper.

If that does not help resolve your issue you may want to consider conatcting your local product experts.

If you are outside the USA you should contact the local support center in your area which you can find here:
http://www.xerox.com/about-xerox/contact-us/enus.html

Mitch Swetsky
Xerox Customer Tools & Social Media Moderator

Please be sure to select «Accept Solution» and or select the thumbs up icon to enter Kudos for posts that resolve your issues.
Your feedback counts!

Источник

Error 077 901 xerox

КОНФЕРЕНЦИЯ СТАРТКОПИ
Принтеры, копировальные аппараты, МФУ, факсы и другая офисная техника:
вопросы ремонта, обслуживания, заправки, выбора

0. Andrey67 21.10.14 15:20

принесли с диагнозом (захватил пачку бумагу, вытащили сами)
теперь ситуация следующая, бумага лежит, нажимаю копировать, он копию печатает и пишет ошибку нет бумаги и так раза 3 делает, на 4 раз проходит нормально, но иногда вообще останавливается после ролика захвата, на датчике бумаги
тут я нашел что ось с роликом захвата могла закрутиться, сами понимаете аппарат геморойные надо весь разбирать, вот вопрос стоит ли разбирать смотреть ось

1. Владимир А. 21.10.14 15:24

Andrey67 (0): захватил пачку бумагу, вытащили сами

Очень вероятно, что ось погнули. Чтоб добраться до оси —почти полностью надо раскидать аппаратик. Решать Вам, разбирать иль нет.

Andrey67 (0): вопрос стоит ли разбирать смотреть ось — скорее философский, чем технический. Задача известна, затраты труда — тоже, клиент доступен — решайте.

3. Andrey67 21.10.14 15:28

да тут еще интересная ситуация, когда кладешь пачку он захватывает два листа, один проходит, второй под роликом остается и аппарат пишет ошибку 077-901(застряла бумага на рег.) бумагу вытаскиваю крышку заднюю открываю, появляется следующая ошибка (024-958 несовпадение формата) и так два три раза потом берет хорошо

Andrey67 (3): захватывает два листа
Привет от тормозной площадки?
Пробег аппарата — сколько?

5. Andrey67 21.10.14 15:39

пробег не смотрел, врать не буду (стоит в школе пару лет)
а что с площадкой . вроде она на хорошей пружине, ходит свободно

6. Портной Нёма 21.10.14 15:48

(5) Все эти ошибки и проблемы — из-за погнутой оси ролика подачи. Проблема стара, как и сама модель — «пластилиновый» металл оси. Только в старых моделях Самсунга она скручивалась винтом, тут она просто изгибается. Тормозная площадка не причем. Служит весь срок жизни аппарата (30к)

7. Владимир А. 21.10.14 15:48

Andrey67 (3): да тут еще интересная ситуация, когда кладешь пачку он захватывает два листа, один проходит, второй под роликом остается и аппарат пишет ошибку 077-901(застряла бумага на рег.) бумагу вытаскиваю крышку заднюю открываю, появляется следующая ошибка (024-958 несовпадение формата

Не в тормозной тут дело, а в оси!

8. Andrey67 21.10.14 15:49

спасибо буду добираться, это копец чтобы ось посмотреть надо снять все

Источник

Error 077 901 xerox

КОНФЕРЕНЦИЯ СТАРТКОПИ
Принтеры, копировальные аппараты, МФУ, факсы и другая офисная техника:
вопросы ремонта, обслуживания, заправки, выбора

0. SamoДелкин 11.09.17 15:28

Доброго времени суток аппарат Xerox Colour 550 при печати черно-белых страниц работает нормально, при печати в цвете происходит 077-909, лист доходит до места соприкосновения с лентой переноса и прижимным валом. Были заменены драм-юниты. Датчики все на месте + почищены. Кто нибудь сталкивался с такой проблемой??

А что нам на это сервис мануал говорит??

Сервис-мануал в категорической форме предлагает лицам без соответствующей (хотя бы минимальной) подготовки (да еще без техдокументации) отойти от аппарата не менее чем на 10 футов.

(3) а мы поощряем ремонты клиентами)))))

5. Bad_engineer 11.09.17 18:46

Датчик печной на выходе на трёх защёлках, вот он вылетел из своего посадочного места. Открутить чёрный пластмассовый поддон печки и увидите датчик который скорее всего не на месте, поправить труда не составит.

7. Сообщения, прямо не связанные с обсуждаемыми в данной теме вопросами (т.е. флуд). Таковыми считаются, например, не несущие полезной информации комментарии, включая демонстрацию чувства юмора, а также банальности типа «отнеси в сервис- центр»; как флуд рассматривается и создание тем, не являющихся профильными для данного раздела (исключая ошибочное создание тем не в том подразделе профильного раздела такие темы будут перемещаться модераторами в нужный подраздел).

Bad_engineer (5): Сообщения, прямо не связанные
Это к чему?

7. Bad_engineer 11.09.17 19:08

Я бы обоих в бан отправил. Надоели уже со своими «ценными» советами.
Угу, хрю, му.

Bad_engineer (7): Я бы обоих в бан отправил
С какого вдруг перепугу (чисто из праздного любопытства)?
Bad_engineer (7): Надоели уже со своими «ценными» советами
Вам вроде давным-давно никто ничего уже не советует. Так что не будите лихо.

http://s48.radikal.ru/i122/1709/74/0b3df443296b.jpg
#640K88769 Xerox DocuColor 700 550 560 Fuser Exit Switch Actuator

10. alexan62 12.09.17 19:09

(5) а черно-белые листы проходят мимо датчика выходного? Мне кажется, Вы советуете что-то не совсем то, хотя проверить датчик не помешает.

alexan62 (10): Мне кажется, Вы советуете что-то не совсем то
Могу выразиться точнее: явно совсем не то.

Есть такое мнение:
640K88769 Xerox DocuColor 700 550 560 Fuser Exit Switch Actuator
Product Description
Xerox® DocuColor 700 550 560 Fuser Exit Switch Actuator & Sensor 640K88769
Includes the sensor and sensor flag. Fixes error 077-909 or 77-909

13. alexan62 13.09.17 12:38

(12) вообще-то мануал трактует эту ошибку иначе, выходной датчик лишь одна, хоть и частая, причина этой ошибки. к тому же, напоминаю, черно-белые листы как-то проходят. или нет?

14. Grani12 13.09.17 20:34

как вариант. EUREKA #1287386, install a new OHP sensor 960K16660 and chage NVM location 742-180 =1.

15. SamoДелкин 18.09.17 16:36

сново всем доброго времени. Датчик под печкой в нормальном положении и состоянии, в черно-белом режиме печатает норм, если даже положить черно-белый тест лист и выбрать функцию печатать в цвете, выпадает в данную ошибку

16. dimedrol 19.09.17 11:02

Ошибка 077-909 иот статик джем,- это следствие после застревания, а причина скорее всего в ксерографии ( раз связано с цветом). Посмотри журнал ошибок должны быть другие

17. dimedrol 19.09.17 11:27

и еще, когда лист останавливается на переносе — изо на IBT присутствует? Если не знаете как посмотреть- НЕ ЛЕЗьТЕ. в этот аппарат, а вызовите спеца ( дешевле будет)

Источник

Понравилась статья? Поделить с друзьями:
  • Xoauth2 ошибка подтверждения подлинности
  • Xmeye ошибка wan ip
  • Xerox versalink c7030 ошибка 024 965
  • Xnview ошибка при открытии файла
  • Xmeye ошибка 604000 при входе