Здравствуйте. Я не могу настроить сканирование в папку на компьютере в простой домашней сети.
Есть два домашних компьютера и МФУ Xerox WC6515. Всё это соединено между собой через роутер. Имена компов в сети — К1 и К2. Учетная запись на компах одна единственная, без пароля. Папка для сканов — \\K2\Scan, расшарена, полный доступ для «Все» и «Администраторы».
В соответствующем веб-диалоге создаю контакт для сканирования, указываю следующее:
имя — К2, порт — 139, общий ресурс — Scan, имя и пароль пустые. В результате, после сканирования, МФУ показывает ошибку: «018-505: SMB-DOS protocol error 1-005».
Комментарий модератора | ||
|
I am setting up and office for some clients. They have a new Xerox WorkCenter 7328 and we have it setup for network scanning. I installed and setup a Samba server using Ubuntu Server 7.10. This involved setting up a repository and shares and so on. I had issues at first but mostly involving permissions. Once I got that setup correctly it all worked great. But then we decided to get a new hard drive (the original was an old 40gig and we got a new 320gig HD). I thought I’d be able to image it over but then ran into the fact that the ext3 file system doesn’t allow you to resize the partition. So I decided to just redo it all on the new HD. But now it won’t successfully scan to the server. I keep getting «Completed with Error (018-505): SMB-DOS protocol error 1-005». I double and triple checked the user name and password and they are correct. I’ve messed with permissions but this seems to be different than the problem I was having the first time. I put the old HD back in and it works fine. So I either need to be able to figure out how to get the new setup working or how to image the old drive to the new one and be able to utilize the free space that the 320GB gives over the old 40GB. Please let me know if you have any idea. Thanks, Eric.
Server SoftwareLinux DistributionsSystem Utilities
Problem : Xerox network scanning to a Linux/Samba server giving Protocol Error.
I am setting up and office for some clients. They have a new Xerox WorkCenter 7328 and we have it setup for network scanning. I installed and setup a Samba server using Ubuntu Server 7.10. This involved setting up a repository and shares and so on. I had issues at first but mostly involving permissions. Once I got that setup correctly it all worked great. But then we decided to get a new hard drive (the original was an old 40gig and we got a new 320gig HD). I thought I’d be able to image it over but then ran into the fact that the ext3 file system doesn’t allow you to resize the partition. So I decided to just redo it all on the new HD. But now it won’t successfully scan to the server. I keep getting “Completed with Error (018-505): SMB-DOS protocol error 1-005”. I double and triple checked the user name and password and they are correct. I’ve messed with permissions but this seems to be different than the problem I was having the first time. I put the old HD back in and it works fine. So I either need to be able to figure out how to get the new setup working or how to image the old drive to the new one and be able to utilize the free space that the 320GB gives over the old 40GB. Please let me know if you have any idea
Solution: Xerox network scanning to a Linux/Samba server giving Protocol Error.
I figured it out! The error number that I looked up mentioned that either the user name and/or password were incorrect. I checked it many times so I dismissed this. But then I realized that I had never added a Samba password for the user (I just added the regular unix password ie: passwd ‘user name’). So I then used smbpasswd -a ‘user name’ and setup the Samba password and now everything works great! Thanks for the help arashaga. I still learned from your input
Server Software
Thanks: 0
Likes: 0
Dislikes: 0
-
01-07-2014
#1
Service Manager
1,000+ Posts
- Rep Power
- 46
Xerox WC5225 with error 18-505
Customer called with error 18-505 on WC5225. The information i have so far seems to indicate some king of communication problem between machine and server/computer. Customer gets this when trying to scan to computer.
I asked customer whether they use passwords and he said no and that they have been scanning all alon g with no problem until a few days ago.
Please help as I am a little confused about this and need some direction. Frank/ActionPhotocopy
-
01-08-2014
#2
Re: Xerox WC5225 with error 18-505
18-505 SMB-DOS protocol error.
Unable to authenticate due to an incorrect user name or password. SMB
Check the user name and password with the system administrator. Note, the password cannot be verified. If you have forgotten the password, reset the password.
Note, Verify that the Date and Time on the WorkCentre EXACTLY match the date and time on the network server and destination PC. This is an especially common problem after daylight savings time change.
If none of the above resolve the issue, go to xerox.com to obtain the newest software level and install.
-
01-08-2014
#3
Service Manager
1,000+ Posts
- Rep Power
- 46
Re: Xerox WC5225 with error 18-505
Thanks Tom but as I mentioned they never used passwords for scanning and have never had a problem until a few days ago. Your last suggestion would be best option unless there was a time change by accident recently which caused a mismatch in the time. I am going there tomorrow and will try to obtain more info. Frank
-
01-09-2014
#4
Senior Tech
100+ Posts
- Rep Power
- 29
Re: Xerox WC5225 with error 18-505
Had the same symptoms on a 128. Turned out to be the modem for their broadband. The phone company changed it, somehow it had different settings. A few days later, no worky.
Glenn
-
01-09-2014
#5
Service Manager
1,000+ Posts
- Rep Power
- 46
Re: Xerox WC5225 with error 18-505
Thanks Glenn. That’s good to know and I’ll look into it and report results when call is complete. Frank