124-313, 124-356 DC132 Error 10 RAP
124-313 Stored data mismatch. The serial numbers do not match.
124-356 Serial number 1 point mismatch.
Procedure
WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.
1. Switch off, then switch on the machine, GP 10. The fault persists. If YES, go to 3. If NO, go to 2.
2. Perform SCP 5 Final Actions.
3. Enter dC132 Device ID and Billing Data. The 3 values match. If YES, go to 5. If NO, go to 4.
4. Perform dC132. Make all three values the same.
5. Perform Software Loading via the Special Boot Menu, GP 4.
If the fault persists, install a new components as necessary:
• ESS PWB, PL 3.10 Item 6.
• Drive PWB, PL 1.10 Item 4.
**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
BSD-ON:
BSD 3.8 — Electronic Billing
The machine codes do not match.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following procedure to repair
it.
Execute
Machine ID/Billing
Data. Compare the 3 product No. All 3 numbers are different.
Y
N
Execute
Machine ID/Billing
Data. Make the 3 values match. Replace the PWB that
doesn’t match.
Reload software
GP
16. Replace the MCU PWB
Status Indicator RAPs
124-312, 124-313
(PL
18.2) and the ESS PWB
(PL
35.2).
BUS Updated 12/2011
124-313 Serial Number RAP
BSD-ON:
BSD 3.8 — Electronic Billing
The serial numbers did not match.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following procedure to repair
it.
Execute
Machine ID/Billing
Data. Compare the 3 product No. All 3 numbers are different.
Y
N
Execute
Machine ID/Billing
Data. Make the 3 values match. Replace the PWB that
doesn’t match.
Reload software
GP
16. Replace the MCU PWB
07/2011
2-958
(PL
18.2) and the ESS PWB
(PL
35.2).
Initial Issue
WorkCentre 5335 Family Service Documentation
124-313, 124-356 DC132 Error 10 RAP
124-313 Stored data mismatch. The serial numbers do not match.
124-356 Serial number 1 point mismatch.
Procedure
WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.
1. Switch off, then switch on the machine, GP 10. The fault persists. If YES, go to 3. If NO, go to 2.
2. Perform SCP 5 Final Actions.
3. Enter dC132 Device ID and Billing Data. The 3 values match. If YES, go to 5. If NO, go to 4.
4. Perform dC132. Make all three values the same.
5. Perform Software Loading via the Special Boot Menu, GP 4.
If the fault persists, install a new components as necessary:
• ESS PWB, PL 3.10 Item 6.
• Drive PWB, PL 1.10 Item 4.
**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
124-315, 317, 355 DC132 Error 02, 04 and 14 RAP
124-315 Stored data mismatch. Internal control error was detected.
124-317 Stored data mismatch. Internal control error was detected.
124-355 At least one set of territory information at the 3 locations is different.
Procedure
WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.
1. Switch off, then switch on the machine, GP 10. The fault persists.
2. Perform SCP 5 Final Actions.
3. Enter dC131 Compare NVM values 700-600, 700-601 and 700-602. The 3 values match.
4. Perform dC132. Make all three values the same.
5. Perform Software Loading via the Special Boot Menu, GP 4.
If the fault persists, install a new components as necessary:
• ESS PWB, PL 3.10 Item 6.
• Drive PWB, PL 1.10 Item 4.
**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
Article Id: 1100440
|
Published: 12/07/2018
Product support for
- Xerox 4590™ Copier
- Xerox 4590™ Copier/Printer
- Xerox 4110 Copier
- Xerox 4110 Enterprise Printing System
- Xerox 4110 Copier/Printer
- Xerox 4590 Enterprise Printing System
- 4595 Copier/Printer with FreeFlow™ Print Server
Перейти к контенту
124-315, 317, 355 DC132 Error 02, 04 and 14 RAP
124-315 Stored data mismatch. Internal control error was detected.
124-317 Stored data mismatch. Internal control error was detected.
124-355 At least one set of territory information at the 3 locations is different.
Procedure
WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.
1. Switch off, then switch on the machine, GP 10. The fault persists.
2. Perform SCP 5 Final Actions.
3. Enter dC131 Compare NVM values 700-600, 700-601 and 700-602. The 3 values match.
4. Perform dC132. Make all three values the same.
5. Perform Software Loading via the Special Boot Menu, GP 4.
If the fault persists, install a new components as necessary:
• ESS PWB, PL 3.10 Item 6.
• Drive PWB, PL 1.10 Item 4.
**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
Article Id: 1100440
|
Published: 12/07/2018
Product support for
- Xerox 4590™ Copier
- Xerox 4590™ Copier/Printer
- Xerox 4110 Copier
- Xerox 4110 Enterprise Printing System
- Xerox 4110 Copier/Printer
- Xerox 4590 Enterprise Printing System
- 4595 Copier/Printer with FreeFlow™ Print Server
Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.
-
sandokan
- Сообщения: 2
- Стаж: 7 месяцев
Xerox B405. Ошибка 124-315
-
0
-
Цитата
Сообщение
sandokan » 07 июн 2022, 15:04
Всем привет!
Versalink B405. Ушел в сон и не вернулся. При перезагрузке виснет на заставке Xerox. Грешу на плату EMMC, которая втыкается в форматер.
Нашел б/у с другого аппарата. Теперь при загрузке ошибка 124-315. По идее это несовпадение данных по серийнику в ней и в форматере.
Но не могу эти данные переписать через команду DC132. Пишет «invalid serial number». Кто-то проделывал такую процедуру на этих аппаратах?
-
-
Похожие темы
- Ответы
- Просмотры
- Последнее сообщение
-
-
- 7 Ответы
- 373 Просмотры
- Последнее сообщение
27 дек 2022, 15:44
-
- 2 Ответы
- 338 Просмотры
- Последнее сообщение
03 июн 2022, 03:49
-
- 1 Ответы
- 166 Просмотры
- Последнее сообщение
02 июн 2022, 13:53
-
- 4 Ответы
- 239 Просмотры
- Последнее сообщение
26 сен 2022, 09:56
-
- 0 Ответы
- 104 Просмотры
- Последнее сообщение
05 дек 2022, 09:08
Вернуться в «Лазерная техника»
Перейти
- Оргтехника
- ↳ Лазерная техника
- ↳ Струйная техника
- ↳ Картриджи, тонер, чипы
- ↳ Прочая техника
- ↳ Выбор офисной техники
- Оборудование
- ↳ Программаторы
- ↳ Инструменты и оборудование
- ↳ 3D Печать
- Услуги
- ↳ Куплю
- ↳ Продам-Отдам
- ↳ Ищу работу (подработку)
- ↳ Предлагаю работу (подработку)
- ↳ Разное (поиск запчастей, документации, сотрудничество и прочее)
- Космическая флудилка
- ↳ А поговорить?
- ↳ Самоделки, лайфхаки и хобби
- ↳ Гараж
- ↳ Опросы
- Статьи
- ↳ Статьи
- Карта
- ↳ Точки на карте
- Работа форума
- ↳ Работа форума, предложения и замечания
Thanks: 0
Likes: 0
Dislikes: 0
-
02-12-2016
#1
Senior Tech
250+ Posts
- Rep Power
- 32
Color 550 error code 124-315 caused by taking out battery from main board?
Hello, we are having scan to email issues with this 550 and noticed that it would show yesterday’s date and a few hours behind the correct date. So we thought maybe the CMOS battery was bad on the fiery and it was not syncing properly with the server. We were getting error 016-772 .
While I went to get the battery another tech opened up the 550 and took a small board (Maybe 2 inches by 2 inches) off the main board that holds a larger round battery to test it. When I came back and we put the machine together it shows a terminal error 124-315. We cannot get anything to come up on the display. I am assuming this cleared the ROM chip and the operating system? Could anyone verify this? Also the flash card is missing from the drawer so we have no way of reloading the software. Any help appreciated.
-
02-12-2016
#2
Re: Color 550 error code 124-315 caused by taking out battery from main board?
ROM chips don’t have volatile memory. Only the RAM is volatile and would lose data without power. If what you’ve done is on the fiery, it’s strange that the machine is now giving an error. That error code is data mismatch between machine boards, so you need to do a sync. You sure you pulled the battery from the fiery?
Sent from my iPhone using Tapatalk
-
02-12-2016
#3
Re: Color 550 error code 124-315 caused by taking out battery from main board?
Originally Posted by patterson70
Hello, we are having scan to email issues with this 550 and noticed that it would show yesterday’s date and a few hours behind the correct date. So we thought maybe the CMOS battery was bad on the fiery and it was not syncing properly with the server. We were getting error 016-772 .
While I went to get the battery another tech opened up the 550 and took a small board (Maybe 2 inches by 2 inches) off the main board that holds a larger round battery to test it. When I came back and we put the machine together it shows a terminal error 124-315. We cannot get anything to come up on the display. I am assuming this cleared the ROM chip and the operating system? Could anyone verify this? Also the flash card is missing from the drawer so we have no way of reloading the software. Any help appreciated.
What you removed was the mcu nvm board who keep the machine datas.
If you are lucky men only a simple data syncronization will solve the problem.
If not you must place a call to xerox tech and prepare to sped you a lot of moneys.
-
02-12-2016
#4
Trusted Tech
50+ Posts
- Rep Power
- 18
Re: Color 550 error code 124-315 caused by taking out battery from main board?
You need a new nvm pwb, when you remove battery it kills all software on it, it will be a sold machine also
-
02-15-2016
#5
Senior Tech
250+ Posts
- Rep Power
- 32
Re: Color 550 error code 124-315 caused by taking out battery from main board?
Sorry for the delay in updating. Yes, jhalfhide, we replaced the battery on the Fiery Board but that was not it unfortunately. PArt of the problem was a bad NVM Board as adriansto and mickey singh suggested. We replaced and did a sync and that resolved the 124-315 error. We are still having issues however, sometimes the machine just shuts down and other times it will not power up. It is intermittent. We called in a Xerox Tech and the Fiery was reloaded just to eliminate that issue as we could not log in at times either. And what is weird is the time went back to 2009 and we tried to change it but it won’t change. I think this machine got zapped, it was not protected by any power filter. It could be a board or the power supply unit as well. Will update again when resolved or any other questions.
Bookmarks
Bookmarks
Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
- BB code is On
- Smilies are On
- [IMG] code is On
- [VIDEO] code is On
- HTML code is Off
Forum Rules
Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.
-
sandokan
- Сообщения: 2
- Стаж: 7 месяцев
Xerox B405. Ошибка 124-315
Сообщение
sandokan » 07 июн 2022, 15:04
Всем привет!
Versalink B405. Ушел в сон и не вернулся. При перезагрузке виснет на заставке Xerox. Грешу на плату EMMC, которая втыкается в форматер.
Нашел б/у с другого аппарата. Теперь при загрузке ошибка 124-315. По идее это несовпадение данных по серийнику в ней и в форматере.
Но не могу эти данные переписать через команду DC132. Пишет «invalid serial number». Кто-то проделывал такую процедуру на этих аппаратах?
-
-
Похожие темы
- Ответы
- Просмотры
- Последнее сообщение
-
-
- 7 Ответы
- 401 Просмотры
- Последнее сообщение
27 дек 2022, 15:44
-
- 2 Ответы
- 378 Просмотры
- Последнее сообщение
03 июн 2022, 03:49
-
- 1 Ответы
- 167 Просмотры
- Последнее сообщение
02 июн 2022, 13:53
-
- 4 Ответы
- 243 Просмотры
- Последнее сообщение
26 сен 2022, 09:56
-
- 0 Ответы
- 109 Просмотры
- Последнее сообщение
05 дек 2022, 09:08
-
06-01-2016
#1
Junior Member
- Join Date
- Jun 2016
- Location
- Sochi
- Posts
- 1
- Rep Power
- 0
Xerox Phaser 7100 error 124-315
I have a Xerox 7100 here with error code 124-315. I guess, that like in Xerox 7245 I need to do similar procedure to make printer alive. But I cannot Enter UI Diagnostic mode. If someone knows that, please help.
- January 29, 2015
- ACS
- in Technical
- 5Comments
The serial no., product no., and billing count are stored at three locations; the MCU NVM PWB (IOT), the SEEP ROM (SYS1) on the Backplane (BP) PWB, and the ESS NVM PWB (SYS2). This procedure allows the data in all three locations to be synchronized in case of replacement of one of the PWBs, or due to data corruption associated with one of the following faults:
- 124-324 (3 Billing Counter Mismatch)
124-325 (1 Billing Counter Mismatch; Unable to recover Billing Counter during recovery)
124-312 (Product No. Mismatch)
124-313 (Serial No. Mismatch)
124-310 (Product No. Failure: Not initialized) - 124-311 (Serial No. Failure: Not initialized)
Procedure
- Enter UI Diagnostic mode ( Accessing UI Diagnostics).
Select Adjustment/Others.
Select Machine ID/Billing Data Settings.
Select a PWB with the correct data.
Select Start. - Enter the correct serial number in the Serial Number screen and then select Confirm.
5 Comments
Log in or Sign up
xerox 700 ERROR CODE 124-315
Discussion in ‘Xerox Digital Presses’ started by phong, Apr 2, 2014.
-
phong
Member
- Joined:
- Mar 2014
- Messages:
- 2
- Location:
- Australia
Machine has error message code 124-315 , keeps telling me to replace the toner cartridge. Tried reloading the firmware. no luck. Now been advised to change the motherboard. any one got a 700 mother board or any advice how to fix the problem…
-
adriansto
Senior Member
- Joined:
- Apr 2011
- Messages:
- 139
- Location:
- somewhere in europe, near Black Sea
What mother board do you think you need because are so many.
Do you follow the edoc procedure for 124-315 because this fault code has nothing to do with toner.
I will send you some bulletins to make some checkings -
MarkD
Senior Member
- Joined:
- Apr 2012
- Messages:
- 344
- Location:
- UK
Run GP4 procedure and make sure IOT, SYS1 and SYS2 are equal and contain the correct serial number
—
Mark
(You must log in or sign up to reply here.)
Show Ignored Content
-
Similar Threads
-
Xerox 700 giving error code 061-317
Mister225,
Dec 29, 2021, in forum: Xerox Digital Presses -
Xerox 700 Scanner error 062-380
Mister225,
Nov 17, 2020, in forum: Xerox Digital Presses -
XEROX 7002 HCF error
Garik,
Feb 13, 2017, in forum: Xerox Digital Presses -
Xerox 700 error code 077-220
Loucamp,
Nov 11, 2015, in forum: Xerox Digital Presses -
Error Code 093-599 Xerox Color Cube 8700
uboot,
Aug 18, 2015, in forum: Xerox Digital Presses
- Your name or email address:
- Do you already have an account?
-
- No, create an account now.
- Yes, my password is:
-
Forgot your password?
-
Stay logged in
Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.
-
sandokan
- Сообщения: 2
- Стаж: 10 месяцев
Xerox B405. Ошибка 124-315
Сообщение
sandokan » 07 июн 2022, 15:04
Всем привет!
Versalink B405. Ушел в сон и не вернулся. При перезагрузке виснет на заставке Xerox. Грешу на плату EMMC, которая втыкается в форматер.
Нашел б/у с другого аппарата. Теперь при загрузке ошибка 124-315. По идее это несовпадение данных по серийнику в ней и в форматере.
Но не могу эти данные переписать через команду DC132. Пишет «invalid serial number». Кто-то проделывал такую процедуру на этих аппаратах?
-
-
Похожие темы
- Ответы
- Просмотры
- Последнее сообщение
-
-
- 7 Ответы
- 482 Просмотры
-
Последнее сообщение
27 дек 2022, 15:44
-
- 1 Ответы
- 209 Просмотры
-
Последнее сообщение
02 июн 2022, 13:53
-
- 4 Ответы
- 326 Просмотры
-
Последнее сообщение
26 сен 2022, 09:56
-
- 0 Ответы
- 148 Просмотры
-
Последнее сообщение
05 дек 2022, 09:08
-
- 2 Ответы
- 537 Просмотры
-
Последнее сообщение
03 июн 2022, 03:49
Xerox B405. Ошибка 124-315
Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.
-
sandokan
- Сообщения: 2
- Стаж: 11 месяцев
Xerox B405. Ошибка 124-315
-
0
-
Цитата
Сообщение
sandokan » 07 июн 2022, 15:04
Всем привет!
Versalink B405. Ушел в сон и не вернулся. При перезагрузке виснет на заставке Xerox. Грешу на плату EMMC, которая втыкается в форматер.
Нашел б/у с другого аппарата. Теперь при загрузке ошибка 124-315. По идее это несовпадение данных по серийнику в ней и в форматере.
Но не могу эти данные переписать через команду DC132. Пишет «invalid serial number». Кто-то проделывал такую процедуру на этих аппаратах?
-
-
Похожие темы
- Ответы
- Просмотры
- Последнее сообщение
-
-
- 7 Ответы
- 626 Просмотры
-
Последнее сообщение
27 дек 2022, 15:44
-
- 1 Ответы
- 269 Просмотры
-
Последнее сообщение
02 июн 2022, 13:53
-
- 4 Ответы
- 397 Просмотры
-
Последнее сообщение
26 сен 2022, 09:56
-
- 0 Ответы
- 187 Просмотры
-
Последнее сообщение
05 дек 2022, 09:08
-
- 19 Ответы
- 306 Просмотры
-
Последнее сообщение
27 апр 2023, 16:21
Вернуться в «Лазерная техника»
Перейти
- Оргтехника
- ↳ Лазерная техника
- ↳ Струйная техника
- ↳ Картриджи, тонер, чипы
- ↳ Прочая техника
- ↳ Выбор офисной техники
- Оборудование
- ↳ Программаторы
- ↳ Инструменты и оборудование
- ↳ 3D Печать
- Услуги
- ↳ Куплю
- ↳ Продам-Отдам
- ↳ Ищу работу (подработку)
- ↳ Предлагаю работу (подработку)
- ↳ Разное (поиск запчастей, документации, сотрудничество и прочее)
- Космическая флудилка
- ↳ А поговорить?
- ↳ Самоделки, лайфхаки и хобби
- ↳ Гараж
- ↳ Опросы
- Статьи
- ↳ Статьи
- Карта
- ↳ Точки на карте
- Работа форума
- ↳ Работа форума, предложения и замечания
Xerox B405. Ошибка 124-315
Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.
-
sandokan
- Сообщения: 2
- Стаж: 1 год 3 месяца
Xerox B405. Ошибка 124-315
Сообщение
sandokan »
Всем привет!
Versalink B405. Ушел в сон и не вернулся. При перезагрузке виснет на заставке Xerox. Грешу на плату EMMC, которая втыкается в форматер.
Нашел б/у с другого аппарата. Теперь при загрузке ошибка 124-315. По идее это несовпадение данных по серийнику в ней и в форматере.
Но не могу эти данные переписать через команду DC132. Пишет «invalid serial number». Кто-то проделывал такую процедуру на этих аппаратах?
-
-
Похожие темы
- Ответы
- Просмотры
- Последнее сообщение
-
-
- 7 Ответы
- 967 Просмотры
-
Последнее сообщение
-
- 2 Ответы
- 839 Просмотры
-
Последнее сообщение
-
- 1 Ответы
- 354 Просмотры
-
Последнее сообщение
-
- 4 Ответы
- 526 Просмотры
-
Последнее сообщение
-
- 0 Ответы
- 255 Просмотры
-
Последнее сообщение
We ran into this on a couple of Xerox B405’s after performing a Factory Init procedure. Here is what we did to rectify the fault:
Hold down the Home button for 6 seconds and then release. This brings up a password screen.
At the Password Screen, enter 6-7-8-9 and hit Enter.
Find and press the Diagnostics icon.
Select DC132 Device ID and Billing Data
That should display a screen showing three values assigned to IOT, SYS1 and SYS2 starting with Serial Number. All 3 values need to be the same under each column.
If these values are not the same under each, write down the serial number assigned to IOT.
Then go to the bottom of the screen and select IOT.
Then enter the serial number you just wrote down in both locations on the screen and press OK.
That should do it. The values displayed under IOT, SYS1 and SYS2 should now all be the same and the machine can be rebooted.