          Во время работы с аппаратом могут возникать проблемы, связанные с неисправностями «железа» или ПО. И если расходные материалы можно просто заменить, то с «мозгами» нужно разбираться. Поэтому, для экономии времени и удобства, ниже представлены возможные коды ошибок (FAULT ERROR CODE), которые показывают Xerox DocuColor DC 240/250/242/252/260 и WorkCentre WC 7655/7665/7675/7755/7765/7775 при неисправности, и их значение:

002-770 ERROR — RAP Insufficient HDD capacity while processing the job template within a job.

003-318 ERROR — RAP IIT software failure.

003-319 ERROR — RAP IIT Video Driver Detection Fail.

003-320 ERROR — RAP IIT-ESS Communication Fail 1.

003-321 ERROR — RAP IIT-ESS Communication Fail 2.

003-322 ERROR — RAP IIT-ESS Communication Fail 3.

003-323 ERROR — RAP IIT-ESS Communication Fail 4.

003-324 ERROR — RAP IIT-ESS Communication Fail 5.

003-325 ERROR — RAP IIT-ESS Communication Fail 6.

003-326 ERROR — RAP IIT-ESS Communication Fail 7.

003-327 ERROR — RAP IIT-ESS Communication Fail 8.

003-328 ERROR — RAP IIT-ESS Communication Fail 9.

003-329 ERROR — RAP IIT-ESS Communication Fail 10.

003-330 ERROR — RAP IIT-ESS Communication Fail 11.

003-331 ERROR — RAP IIT-ESS Communication Fail 12.

003-332 ERROR — RAP IIT-ESS Communication Fail 13.

003-333 ERROR — RAP IIT-ESS Communication Fail 14.

003-334 ERROR — RAP IIT-ESS Communication Fail 15.

003-335 ERROR — RAP IIT-ESS Communication Fail 16.

003-336 ERROR — RAP IIT-ESS Communication Fail 17.

003-337 ERROR — RAP IIT-ESS Communication Fail 18.

003-338 ERROR — RAP IIT-ESS Communication Fail 19.

003-339 ERROR — RAP IIT-ESS Communication Fail 20.

003-340 ERROR — RAP IIT-ESS Communication Fail 21.

003-341 ERROR — RAP IIT-ESS Communication Fail 22.

003-342 ERROR — RAP IIT-ESS Communication Fail 23.

003-343 ERROR — RAP IIT-ESS Communication Fail 24.

003-344 ERROR — RAP Power on hotline failure.

003-345 ERROR — RAP X PIO Unmatch Fail 1.

003-346 ERROR — RAP X PIO Unmatch Fail 2.

003-750 ERROR — RAP Book Duplex-Insufficient Docs.

003-751 ERROR — RAP Under PANTHER Capacity (Scan).

003-752 ERROR — RAP This status code is displayed if 600dpi cannot be scanned (DADF).

003-753 ERROR — RAP This status code is displayed if over 300dpi cannot be scanned (DADF).

003-754 ERROR — RAP S2X Recoverable Error.

003-755 ERROR — RAP S2X Command Error.

003-757 ERROR — RAP This status code is displayed if over 400dpi cannot be scanned (DADF).

003-760 ERROR — RAP Scan Settings Error.

003-761 ERROR — RAP Incorrect Paper Tray Size.

003-763 ERROR — RAP Adjustment Chart Not Found.

003-764 ERROR — RAP Adjustment Chart Not Found.

003-780 ERROR — RAP Scan Image Compression Error.

003-795 ERROR — RAP AMS Limit Error.

003-940 ERROR — RAP DAM Memory is insufficient.

003-942 ERROR — RAP Document Size Error.

003-944 ERROR — RAP Image Repeat Count Fail.

003-946 ERROR — RAP Copy Vertical/Horizontal Difference (APS).

003-947 ERROR — RAP Replaced Original Count Error.

003-948 ERROR — RAP Replaced Original Mismatch.

003-952 ERROR — RAP Return Documents Color mismatch.

003-955 ERROR — RAP Documents Size Exchange Error.

003-956 ERROR — RAP Documents Size Unknown Error.

003-963 ERROR — RAP No APS Object Tray.

003-965 ERROR — RAP ATS/APS No Paper. There is no paper in the trays that can be selected with APS.

003-966 ERROR — RAP AATS/APS No Destination Error.

003-968 ERROR — RAP Punch Position Error.

003-969 ERROR — RAP Punch Size Error.

003-972 ERROR — RAP Maximum Stored Page Over Flow.

003-973 ERROR — RAP Every Direction Difference.

003-974 ERROR — RAP Next Original Specification.

003-977 ERROR — RAP Document Miss Match (Multi Scan).

003-978 ERROR — RAP Color Document Mismatch (Multi Scan).

003-980 ERROR — RAP Staple Position Error.

003-981 ERROR — RAP Staple Size Error.

003-982 ERROR — RAP IITsc HDD Access Error.

005-121 ERROR — RAP DADF Feed Sensor ON Jam.

005-122 ERROR — RAP DADF Simplex/Side 1 Pre Reg Sensor ON Jam.

005-123 ERROR — RAP DADF Simplex/Side 1 Reg Sensor ON Jam.

005-124 ERROR — RAP DADF Lead Reg Sensor ON Jam.

005-125 ERROR — RAP DADF Reg Sensor OFF Jam.

005-126 ERROR — RAP DADF Out Sensor ON Jam.

005-127 ERROR — RAP DADF Out Sensor OFF Jam.

005-128 ERROR — RAP DADF Exit Sensor 1 ON Jam (Simplex Mode).

005-129 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Simplex Mode).

005-130 ERROR — RAP DADF Invert Sensor ON Jam (Duplex Mode).

005-131 ERROR — RAP DADF Invert Sensor On Jam (Inverting).

005-132 ERROR — RAP DADF Invert SNR on Jam 2.

005-133 ERROR — RAP DADF Invert Sensor OFF Jam.

005-134 ERROR — RAP DADF Invert SNR off Jam (Inv).

005-135 ERROR — RAP DADF Pre Reg Sensor ON Jam (Invert).

005-136 ERROR — ERROR — RAP DADF Reg Sensor ON Jam (Invert).

005-137 ERROR — RAP DADF Exit Sensor 2 ON Jam.

005-138 ERROR — RAP DADF Exit Sensor 1 ON Jam.

005-139 ERROR — RAP DADF Invert SNR off Jam.

005-141 ERROR — RAP DADF Feed Sensor OFF Jam.

005-142 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Duplex Mode).

005-143 ERROR — RAP DADF Exit Sensor 2 OFF Jam.

005-144 ERROR — RAP DADF Too First Pre Reg Sensor ON Jam.

005-145 ERROR — RAP DADF Reg Sensor Off Jam (Invert).

005-146 ERROR — RAP DADF Pre Reg Sensor Off Jam.

005-147 ERROR — RAP DADF Pre Reg Sensor Off Jam (Invert).

005-150 ERROR — RAP DADF Feed Sensor OFF Jam (Perforated Original Mode).

005-151 ERROR — RAP DADF Pre Reg Sensor OFF Jam (Perforated Original Mode).

005-152 ERROR — RAP DADF Reg Sensor OFF Jam (Perforated Original Mode).

005-153 ERROR — RAP DADF Reg Sensor OFF Jam (Perforated Original Mode).

005-154 ERROR — RAP DADF Out Sensor OFF Jam (Perforated Original Mode).

005-155 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Perforated Original Mode) (Simplex).

005-156 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Perforated Original Mode) (Duplex).

005-157 ERROR — RAP DADF Invert Sensor OFF Jam (Perforated Original Mode).

005-158 ERROR — RAP DADF Exit Sensor 2 OFF Jam (Perforated Original Mode).

005-160 ERROR — RAP DADF Tray Lift Up Fail (Document Set) (Within Job).

005-190 ERROR — RAP DADF Feed Motor Logic Jam.

005-194 ERROR — RAP Size Mismatch Jam on Slow Scan Mix Size.

005-195 ERROR — RAP Size Mismatch Jam on No Mix Size.

005-196 ERROR — RAP Size Mismatch Jam on No Mix Size.

005-197 ERROR — RAP Prohibit Combine Size Jam.

005-198 ERROR — RAP Too Short Size Jam.

005-199 ERROR — RAP Too Long Size Jam.

005-275 ERROR — RAP DADF RAM Fail.

005-280 ERROR — RAP DADF EEPROM Fail.

005-282 ERROR — RAP DADF Tray Lift Up Fail (No Document).

005-283 ERROR — RAP DADF Stack Height Sensor Logic Fail.

005-284 ERROR — RAP DADF APS Sensor Logic Fail.

005-285 ERROR — RAP DADF Nudger Lift Up Fail.

005-286 ERROR — RAP DADF Feed Out Sensor Fail.

005-303 ERROR — RAP DADF Tray Interlock is open.

005-304 ERROR — RAP Platen Interlock Open.

005-305 ERROR — RAP DADF Feeder Cover Interlock Open (Run).

005-306 ERROR — RAP DADF Tray Interlock Open (Run).

005-308 ERROR — RAP The DADF L/H Cover Interlock is open.

005-309 ERROR — RAP DADF L/H Cover Interlock Open (Run).

005-906 ERROR — RAP DADF Feed Sensor Static Jam.

005-907 ERROR — RAP DADF Pre Reg Sensor Static Jam.

005-908 ERROR — RAP DADF Reg Sensor Static Jam.

005-909 ERROR — RAP DADF Lead Reg Sensor Static Jam..

005-910 ERROR — RAP DADF Out Sensor Static Jam.

005-911 ERROR — RAP DADF Exit Sensor 1 Static Jam.

005-912 ERROR — RAP DADF Exit Sensor 2 Static Jam.

005-913 ERROR — RAP DADF Invert Sensor Static Jam.

005-914 ERROR — RAP DADF No. 1/2/3 APS Sensor Static Jam.

005-915 ERROR — RAP DADF No. 1 APS Sensor Static Jam.

005-916 ERROR — RAP DADF No. 2 APS Sensor Static Jam.

005-917 ERROR — RAP DADF No. 3 APS Sensor Static Jam.

005-918 ERROR — RAP DADF Invert Sensor 2 Static Jam.

005-919 ERROR — RAP DADF Tray Lift Up Fail (Document Set).

005-940 ERROR — RAP DADF No Original Fail.

005-941 ERROR — RAP DADF Not Enough Document.

005-942 ERROR — RAP DADF Tray Stack Over Fail.

010-311 ERROR — RAP Fuser Heat Roll STS-1 Disconnection Fail. It was detected that fuser heat roll STS-1 disconnected.

010-319 ERROR — RAP Fuser NC Sensor Differential Amp Fail.

010-320 ERROR — RAP Heat Roll Over Heat Fail.

010-321 ERROR — RAP Fuser Nip Fail.

010-322 ERROR — RAP Fuser NC Center Sensor Disconnection Fail. (Fuser Temperature Sensor Fail).

010-323 ERROR — RAP Fuser Rear Sensor Disconnection Fail. (Fuser Temperature Sensor Fail).

010-324 ERROR — RAP Fuser NVM Fail.

010-326 ERROR — RAP Wait Heat Roll Fuser On Time Fail.

010-327 ERROR — RAP Standby Heat Roll Fuser On Time Fail.

010-330 ERROR — RAP Fuser Motor Fail.

010-420 ERROR — RAP Fuser Assembly Life Near End.

010-421 ERROR — RAP Fuser Assembly Life End.

012-112 ERROR — RAP Finisher Interface Entrance Sensor ON.

012-113 ERROR — RAP Booklet In Sensor ON Jam.

012-114 ERROR — RAP Booklet In Sensor OFF Jam.

012-115 ERROR — RAP Booklet Folder Roll Exit Sensor ON Jam.

012-125 ERROR — RAP Gate Sensor ON JAM: Finisher.

012-132 ERROR — RAP Finisher Transport Entrance Sensor ON Jam (Long).

012-142 ERROR — RAP Buffer Path Sensor ON Jam A.

012-151 ERROR — RAP Compile Exit Sensor OFF Jam.

012-152 ERROR — RAP Compile Exit Sensor ON Jam A.

012-161 ERROR — RAP Set Eject Jam.

012-162 ERROR — RAP Finisher Interface EXIT. Sensor ON Jam.

012-171 ERROR — RAP Top Tray Exit Sensor ON Jam A.

012-172 ERROR — RAP Top Tray Exit Sensor OFF Jam A.

012-180 ERROR — RAP Booklet Folder Roll Exit Sensor OFF Jam.

012-211 ERROR — RAP Stacker Tray Fail.

012-212 ERROR — RAP Stacker Tray Upper Limit Fail.

012-213 ERROR — RAP Stacker Tray Lower Limit Fail.

012-221 ERROR — RAP Tamper Home Sensor ON Fail.

012-223 ERROR — RAP Tamper Home Sensor OFF Fail.

012-224 ERROR — RAP Rear Tamper Home Sensor OFF Fail.

012-225 ERROR — RAP Booklet Tamper F Home Sensor ON Fail.

012-226 ERROR — RAP Booklet Tamper F Home Sensor OFF Fail.

012-227 ERROR — RAP Booklet End Guide Home Sensor OFF Fail.

012-228 ERROR — RAP Booklet End Guide Home Sensor ON Fail.

012-229 ERROR — RAP Booklet Tamper R Home Sensor ON Fail.

012-230 ERROR — RAP Booklet Tamper R Home Sensor OFF Fail.

012-243 ERROR — RAP Booklet Knife Home Sensor ON Fail.

012-246 ERROR — RAP Booklet Stapler Fail.

012-247 ERROR — RAP Side Regi Sensor OFF Fail.

012-260 ERROR — RAP Eject Clamp Up Sensor ON Fail.

012-261 ERROR — RAP Booklet Knife Folding SNR Fail.

012-263 ERROR — RAP Finisher Rear Tamper Home Sensor ON.

012-264 ERROR — RAP Booklet Drawer Broken Fail.

012-265 ERROR — RAP Booklet Knife Home Sensor OFF Fail.

012-266 ERROR — RAP Booklet Compiler No Paper Sensor Fail.

012-270 ERROR — RAP Top Offset Home Sensor ON Fail: Finisher.

012-271 ERROR — RAP Top Offset Home Sensor OFF Fail: Finisher.

012-282 ERROR — RAP Eject Clamp Up Sensor OFF Fail.

012-283 ERROR — RAP Finisher Set Clamp Home Sensor ON Fail.

012-284 ERROR — RAP Finisher Set Clamp Home Sensor OFF Fail.

012-291 ERROR — RAP Stapler Fail.

012-295 ERROR — RAP Finisher Stapler Move Sensor On Fail.

012-296 ERROR — RAP Finisher Stapler Move Sensor OFF Fail.

012-300 ERROR — RAP Finisher Eject Cover Open (Compiler Cover).

012-302 ERROR — RAP Finisher Front Door Interlock Open.

012-307 ERROR — RAP Booklet Drawer Set Fail.

012-320 ERROR — RAP Punch Home Sensor ON Fail.

012-321 ERROR — RAP Punch Home Sensor OFF Fail.

012-322 ERROR — RAP Puncher Move Home Sensor OFF Fail.

012-323 ERROR — RAP Puncher Move Home Sensor On Fail.

012-325 ERROR — RAP Side Regi Home Sensor On Fail.

012-330 ERROR — RAP Decurler Cam Home Sensor OFF Fail.

012-332 ERROR — RAP Decurler Cam Home Sensor ON Fail.

012-334 ERROR — RAP Download Mode Fail.

012-335 ERROR — RAP Booklet Sub CPU Communication Fail.

012-900 ERROR — RAP Buffer Path Sensor Static Jam.

012-901 ERROR — RAP Finisher Paper Remains at H-Transport Entrance.

012-902 ERROR — RAP Finisher Paper Remains H-Transport Exit.

012-903 ERROR — RAP Compile Exit Sensor Static Jam.

012-905 ERROR — RAP Compile Tray No Paper Sensor Static Jam.

012-907 ERROR — RAP Top Tray Exit Sensor Static Jam.

012-920 ERROR — RAP Gate Sensor static JAM (to Top Tray) A: Finisher.

012-932 ERROR — RAP Gate SNR static JAM (to Stacker Tray) A.

012-934 ERROR — RAP Gate SNR static JAM (to Stacker Tray) C.

012-935 ERROR — RAP Finisher Paper Remains at Transport Entrance Sensor.

012-936 ERROR — RAP Paper Remain at Booklet In SNR A.

012-949 ERROR — RAP Finisher Punch DustBox Miss Set.

013-902 ERROR — RAP Booklet Compile No Paper Sensor Static Jam.

013-903 ERROR — RAP Booklet Folder Roll Exit Sensor Static Jam.

016-210 ERROR — RAP Software Option Fail (HDD Not Exist).

016-211 ERROR — RAP Software Option Fail (System Memory Low Volume).

016-212 ERROR — RAP SW Option Fail (Page Memory Low).

016-213 ERROR — RAP SW Option Fail (Printer CARD Not Exist).

016-215 ERROR — RAP SW Option Fail (JPEG Board Not Exist).

016-216 ERROR — RAP SW Option Fail (Ext Memory Not Exist).

016-217 ERROR — RAP SW Option Fail (Controller ROM not Printer kit).

016-218 ERROR — RAP Because PS Kit is not installed, XDOD functions cannot be fulfilled.

016-219 ERROR — RAP License is required (Printer Kit).

016-220 ERROR — RAP S2X Unrecoverable Error.

016-221 ERROR — RAP S2X Communication Error.

016-222 ERROR — RAP S2X Self-Diag Error.

016-223 ERROR — RAP SS2X SDRAM Error.

016-224 ERROR — RAP S2X PCI Reg Error.

016-225 ERROR — RAP S2X ROM CheckSum Error.

016-226 ERROR — RAP S2X IIT Connection Error.

016-227 ERROR — RAP S2X DDR Error.

016-228 ERROR — RAP S2X Image Processing Error.

016-229 ERROR — RAP SW Option Fail (FCW-UI Not Exist).

016-311 ERROR — RAP The scanner was not detected.

016-315 ERROR — RAP NIIT Interface Fail.

016-316 ERROR — RAP Page Memory Not Detected.

016-317 ERROR — RAP Page Memory Broken-Standard.

016-318 ERROR — RAP Page Memory Broken-Option.

016-320 ERROR — RAP A fatal error with doc conversion software was detected.

016-322 ERROR — RAP JBA Account Full.

016-450 ERROR — RAP SMB Host Name Duplicated.

016-454 ERROR — RAP DNS Renewal Failure of Dynamic.

016-455 ERROR — RAP SNTP Server Time Out.

016-456 ERROR — RAP SNTP Time Asynchronous.

016-503 ERROR — RAP SMTP Server Address Resolution Fail.

016-504 ERROR — RAP POP Server Address Resolution Fail.

016-505 ERROR — RAP POP Authentication Fail.

016-600 ERROR — RAP KO Authentication Locked.

016-601 ERROR — RAP Illegal Access Detection.

016-647 ERROR — RAP With APS selected or with APS set up, there were no trays loaded with paper sizes for Auto Paper Selection.

016-648 ERROR — RAP Job with Booklet selected was discontinued because it had a cover with an image, a divider, or a blank page.

016-701 ERROR — RAP Out of ART EX Memory.

016-702 ERROR — RAP Out of Page Buffer.

016-703 ERROR — RAP Email to Invalid Box.

016-704 ERROR — RAP Mailbox is Full.

016-705 ERROR — RAP Secure Print Fail.

016-706 ERROR — RAP Max. User Number Exceeded.

016-707 ERROR — RAP Sample Print Fail.

016-708 ERROR — RAP HD Full by Annotation/Watermark Image.

016-709 ERROR — RAP ART EX Command Error.

016-710 ERROR — RAP Delayed Print Fail.

016-711 ERROR — RAP Tried to send data whose size is over the system data upper limit.

016-712 ERROR — RAP Under PANTHER Capacity (I-Formatter).

016-713 ERROR — RAP Security Box Password Error.

016-714 ERROR — RAP Security Box is not Enabled.

016-716 ERROR — RAP TIFF Data Overflow.

016-718 ERROR — RAP Out of PCL6 Memory.

016-719 ERROR — RAP Out of PCL Memory.

016-720 ERROR — RAP PCL Command Error.

016-721 ERROR — RAP Other Error.

016-722 ERROR — RAP Job Cancel by Staple Position NG.

016-723 ERROR — RAP Job Cancel by Punch Position NG.

016-724 ERROR — RAP Complex Position Error of Staple and Punch.

016-726 ERROR — RAP PDL Auto Switch Fail.

016-728 ERROR — RAP Unsupported TIFF Data.

016-729 ERROR — RAP TIFF Data Size too Big.

016-730 ERROR — RAP Unsupported ART Command.

016-731 ERROR — RAP Invalid TIFF Data.

016-732 ERROR — RAP Form Not Registered.

016-733 ERROR — RAP Destination Address Resolution Error.

016-734 ERROR — RAP Simple Transmission report invocation error.

016-735 ERROR — RAP Updating Job Template.

016-736 ERROR — RAP Remote directory lock error. Lock directory creation failed.

016-737 ERROR — RAP Remote lock directory remove error.

016-738 ERROR — RAP PS Booklet Print Output Paper Size is illegal.

016-739 ERROR — RAP Mismatch between PS Booklet Doc and Output Paper.

016-740 ERROR — RAP PS Booklet Output Tray is incorrect.

016-746 ERROR — RAP Unsupported PDF File.

016-748 ERROR — RAP HD Full.

016-749 ERROR — RAP JCL Syntax Error.

016-751 ERROR — RAP PDF Error.

016-752 ERROR — RAP PDF Short of Memory.

016-753 ERROR — RAP PDF Password Mismatched.

016-754 ERROR — RAP PDF LZW Not Installed.

016-755 ERROR — RAP PDF Print Prohibited.

016-756 ERROR — RAP Auditron-Prohibit Service.

016-757 ERROR — RAP Auditron-Invalid User.

016-758 ERROR — RAP Auditron-Disabled Function.

016-759 ERROR — RAP Auditron-Reached Limit.

016-760 ERROR — RAP PS Decompose Failure.

016-761 ERROR — RAP FIFO Empty.

016-762 ERROR — RAP Print LANG Not Installed.

016-764 ERROR — RAP SMTP Server Connect Error.

016-765 ERROR — RAP SMTP Server HD Full.

016-766 ERROR — RAP SMTP Server File System Error.

016-767 ERROR — RAP Invalid E-mail Address.

016-768 ERROR — RAP Invalid Sender Address.

016-769 ERROR — RAP SMTP Server Unsupported DSN.

016-771 ERROR — RAP Scan Data Repository ERR.

016-772 ERROR — RAP Scan Data Repository ERR.

016-773 ERROR — RAP Invalid IP Address.

016-774 ERROR — RAP HD Full-Compression Convert.

016-775 ERROR — RAP HD Full-Image Convert.

016-776 ERROR — RAP Image Convert ERR.

016-777 ERROR — RAP HD Access ERR-Image Convert.

016-778 ERROR — RAP HD Full-Scan Image Convert.

016-779 ERROR — RAP Scan Image Conversion Error.

016-780 ERROR — RAP HD Access ERR-Image Convert.

016-781 ERROR — RAP Scan Server Connect ERR.

016-782 ERROR — RAP Scan Server Login ERR.

016-783 ERROR — RAP Invalid Server Path.

016-784 ERROR — RAP Server Write ERR.

016-785 ERROR — RAP Server HD Full.

016-786 ERROR — RAP HD Full-Scan Write ERR.

016-787 ERROR — RAP Invalid Server IP ADD.

016-788 ERROR — RAP Retrieve to Browser Failed.

016-789 ERROR — RAP HD Full-Job Memory.

016-791 ERROR — RAP File Retrieve Fail.

016-792 ERROR — RAP Specified Job Not Found.

016-793 ERROR — RAP MF I/O HD Full.

016-794 ERROR — RAP Media Reader: Media No Insert.

016-795 ERROR — RAP Media Reader: Format Error.

016-796 ERROR — RAP Document insert operation error.

016-797 ERROR — RAP Media Reader: Image File Read Error.

016-798 ERROR — RAP No Trust Marking Option.

016-799 ERROR — RAP Print Instruction Fail.

016-940 ERROR — RAP With Duplex Output selected, a size difference between side 1 and side 2 was detected.

016-941 ERROR — RAP With Booklet selected, mixed-in-size/orientation pages with images were detected.

016-942 ERROR — RAP After a duplexed page was deleted, a size difference between side 1 and side 2 was detected.

016-943 ERROR — RAP After a document or divider was inserted, a size difference between side 1 and side 2 was detected.

016-944 ERROR — RAP Documents were merged, including the cover with an image, or a document with a divider.

016-945 ERROR — RAP A document unavailable for duplex print was inserted after a document available for Duplex was inserted.

016-946 ERROR — RAP A document or a divider was inserted after the cover or divider page.

016-949 ERROR — RAP The user inserted a documnet different in size/orientation from the page to be processed.

016-981 ERROR — RAP A failure in access to HDD.

016-982 ERROR — RAP HDD Access Error 2.

016-985 ERROR — RAP Data Size Over Flow (Scan to Email).

024-340 ERROR — RAP IOT-ESS Communication Failure 1.

024-341 ERROR — RAP IOT-ESS Communication Failure 2.

024-342 ERROR — RAP IOT-ESS Communication Failure 3.

024-343 ERROR — RAP IOT-ESS Communication Failure 4.

024-345 ERROR — RAP IOT-ESS Communication Failure 5.

024-346 ERROR — RAP IOT-ESS Communication Failure 6.

024-347 ERROR — RAP IOT-ESS Communication Failure 7.

024-348 ERROR — RAP IOT-ESS Communication Failure 8.

024-349 ERROR — RAP IOT-ESS Communication Failure 9.

024-350 ERROR — RAP IOT-ESS Communication Failure 10.

024-351 ERROR — RAP IOT-ESS Communication Failure 11.

024-352 ERROR — RAP IOT-ESS Communication Failure 12.

024-353 ERROR — RAP IOT-ESS Communication Failure 13.

024-354 ERROR — RAP IOT-ESS Communication Failure 14.

024-355 ERROR — RAP IOT-ESS Communication Failure 15.

024-356 ERROR — RAP IOT-ESS Communication Failure 16.

024-357 ERROR — RAP IOT-ESS Communication Failure 17.

024-358 ERROR — RAP IOT-ESS Communication Failure 18.

024-359 ERROR — RAP IOT-ESS Communication Failure 19.

024-360 ERROR — RAP IOT-ESS Initialization Failure.

024-361 ERROR — RAP Invalid IOT PaperSizeGroup Information.

024-362 ERROR — RAP Page Sync Illegal Start.

024-363 ERROR — RAP Page Sync Illegal Stop.

024-364 ERROR — RAP DMA Transfer Failure.

024-365 ERROR — RAP Overflow on the Loop Back Write.

024-366 ERROR — RAP JBIG Library Other Failure.

024-367 ERROR — RAP Decompress Other Failure.

024-368 ERROR — RAP PCI Error.

024-370 ERROR — RAP Marker Code Detect Failure.

024-371 ERROR — RAP IOT-ESS Communication Failure 21.

024-372 ERROR — RAP IOT-ESS Communication Failure 22.

024-373 ERROR — RAP IOT-ESS Communication Failure 23.

024-374 ERROR — RAP Regi Con PLL Parameter Failure.

024-375 ERROR — RAP IOT-ESS Communication Failure 24.

024-600 ERROR — RAP Billing master counter repair.

024-601 ERROR — RAP Billing backup counter #1 repair.

024-602 ERROR — RAP Billing backup counter #2 repair.

024-603 ERROR — RAP SWKey master counter repair.

024-604 ERROR — RAP SWKey backup counter #1 repair.

024-605 ERROR — RAP SWKey backup counter #2 repair.

024-606 ERROR — RAP Production Number/Serial Number Failure.

024-746 ERROR — RAP Selected Paper Tray Parameter Mismatch.

024-747 ERROR — RAP Print Instruction Failure.

024-910 ERROR — RAP Tray 1 Size Mismatch.

024-911 ERROR — RAP Tray 2 Size Mismatch.

024-912 ERROR — RAP Tray 3 Size Mismatch.

024-913 ERROR — RAP Tray 4 Size Mismatch.

024-914 ERROR — RAP Tray 6 Size Mismatch.

024-915 ERROR — RAP Tray 7 Size Mismatch.

024-917 ERROR — RAP Stacker Tray Staple Set Over Count.

024-919 ERROR — RAP Face UP Tray Close.

024-920 ERROR — RAP Face Down Tray 1 Paper FULL.

024-922 ERROR — RAP Face Down Tray 2 Paper FULL.

024-923 ERROR — RAP Operation Yellow Toner Empty.

024-924 ERROR — RAP Operation Magenta Toner Empty.

024-925 ERROR — RAP Operation Cyan Toner Empty.

024-926 ERROR — RAP Punch Dust Box Missing Set.

024-927 ERROR — RAP Offset Catch Tray Full Stack.

024-930 ERROR — RAP Stacker Tray Full (Small Size Full).

024-934 ERROR — RAP Paper type mismatch.

024-935 ERROR — RAP Tray 1 Paper Mismatch.

024-936 ERROR — RAP Tray 2 Paper Mismatch.

024-937 ERROR — RAP Tray 3 Paper Mismatch.

024-938 ERROR — RAP OHP kind Mismatch at Tray 4 (Not White Frame OHP).

024-939 ERROR — RAP Transparency type mismatch (No white border).

024-940 ERROR — RAP Folder Tray Out of Place.

024-941 ERROR — RAP Folder Tray Full Stack.

024-942 ERROR — RAP Booklet Sheets Over Count.

024-943 ERROR — RAP Booklet Low Staple.

024-945 ERROR — RAP Booklet Full Stack.

024-946 ERROR — RAP Tray 1 Not In Position.

024-947 ERROR — RAP Tray 2 Not In Position.

024-948 ERROR — RAP Tray 3 Not In Position.

024-949 ERROR — RAP Tray 4 Not In Position.

024-950 ERROR — RAP Tray 1 No Paper.

024-951 ERROR — RAP Tray 2 No Paper.

024-952 ERROR — RAP Tray 3 No Paper.

024-953 ERROR — RAP Tray 4 No Paper.

024-954 ERROR — RAP MSI No Paper.

024-955 ERROR — RAP Tray 6 No Paper.

024-956 ERROR — RAP Tray 7 No Paper.

024-957 ERROR — RAP Interposer No Paper.

024-958 ERROR — RAP MSI Size Mismatch.

024-959 ERROR — RAP Tray 1 Paper Size Mismatch.

024-960 ERROR — RAP Tray 2 Paper Size Mismatch.

024-961 ERROR — RAP Tray 3 Paper Size Mismatch.

024-962 ERROR — RAP Tray 4 Paper Size Mismatch.

024-965 ERROR — RAP ATS/APS No Paper.

024-966 ERROR — RAP ATS/APS No Destination Error.

024-967 ERROR — RAP Different Width Mix Paper Detect (Staple Job).

024-968 ERROR — RAP Stapler/Punch Batting.

024-969 ERROR — RAP Different Width Mix Punch.

024-970 ERROR — RAP Tray 6 Not In Position.

024-971 ERROR — RAP Tray 7 Not In Position.

024-972 ERROR — RAP Tray 6 Paper Size Mismatch.

024-973 ERROR — RAP Tray 7 Paper Size Mismatch.

024-974 ERROR — RAP Interposer Tray Size Mismatch.

024-975 ERROR — RAP Booklet Sheets Over Count (Not Field Attachment).

024-976 ERROR — RAP Finisher Staple Status incorrect.

024-977 ERROR — RAP Stapler Feed Ready Failure.

024-978 ERROR — RAP Booklet Stapler incorrect.

024-979 ERROR — RAP Stapler Near Empty.

024-980 ERROR — RAP Finisher Stacker Tray Full.

024-981 ERROR — RAP Finisher Top Tray Full.

024-982 ERROR — RAP Stacker Lower Safety Warning.

024-983 ERROR — RAP Booklet Tray Full.

024-984 ERROR — RAP Booklet Low Staple F.

024-985 ERROR — RAP SMH Stop Check.

024-987 ERROR — RAP Envelope Folder Tray Full.

024-988 ERROR — RAP Envelope Folder Tray Set Failure.

024-989 ERROR — RAP Booklet Low Staple R.

024-990 ERROR — RAP Punch Dust Full.

025-596 ERROR — RAP Diag HDD Failure 1.

025-597 ERROR — RAP Diag HDD Failure 2.

027-452 ERROR — RAP Duplicate IP address.

027-500 ERROR — RAP SMTP Server Address Resolution Failure.

027-501 ERROR — RAP POP Server Address Resolution Failure.

027-502 ERROR — RAP POP Authentication Failure.

027-700 ERROR — RAP Media Failure.

027-701 ERROR — RAP Media Not Found.

027-702 ERROR — RAP Media Data Not Found / Not Supported.

027-703 ERROR — RAP Media Reader Failure / Disconnected.

027-706 ERROR — RAP Certificate not found.

027-707 ERROR — RAP Certificate expired.

027-708 ERROR — RAP Certificate untrusted.

027-709 ERROR — RAP Certificate revoked.

027-710 ERROR — RAP S/MIME mail was disabled.

027-711 ERROR — RAP S/MIME mail sender certificate not found.

027-712 ERROR — RAP S/MIME mail sender certificate not valid.

027-713 ERROR — RAP S/MIME mail was altered.

027-714 ERROR — RAP S/MIME mail sender impersonation.

027-715 ERROR — RAP S/MIME mail certificate not supported.

027-716 ERROR — RAP No-Signed mail receipt was rejected.

027-720 ERROR — RAP Ext Srv. Host Not Found. A server specified for a remote application was not found, or DNS resolution was not possible.

027-721 ERROR — RAP Ext Srv. Not Found.

027-722 ERROR — RAP Ext Srv. Timeout Failure.

027-723 ERROR — RAP Ext Srv. Authentication Failure.

027-724 ERROR — RAP Ext Srv. Access Failure.

027-725 ERROR — RAP Ext Srv. Operation Failure.

027-726 ERROR — RAP Ext Srv. Unknown State.

027-727 ERROR — RAP Ext Srv. Req Invalid Parameters.

027-728 ERROR — RAP Ext Srv. Required File Exceeded.

027-737 ERROR — RAP Template Server Read Error.

027-739 ERROR — RAP Invalid Template Server Path.

027-740 ERROR — RAP Template Server Login Error.

027-741 ERROR — RAP Template Server Connect Failure.

027-742 ERROR — RAP HD File System Full.

027-743 ERROR — RAP Template Server Install Error.

027-744 ERROR — RAP Template Server ADD Error.

027-745 ERROR — RAP Template Server ADD Error.

027-746 ERROR — RAP Job Template Pool Server Not Ready.

027-751 ERROR — RAP Job Template Analysis Error.

027-752 ERROR — RAP Must User un Inputting.

027-753 ERROR — RAP Job Flow Service Request Disabled.

027-760 ERROR — RAP XJT Command Failure.

027-770 ERROR — RAP PDL Error.

027-771 ERROR — RAP DFE Disk Full.

027-796 ERROR — RAP Email Not Printed.

027-797 ERROR — RAP Invalid Output Destination.

042-313 ERROR — RAP Rear Cooling Fan Failure.

042-320 ERROR — RAP Yellow Drum Motor Drive Failure.

042-321 ERROR — RAP Magenta Drum Motor Drive Failure.

042-322 ERROR — RAP Cyan Drum Motor Drive Failure.

042-323 ERROR — RAP Black Drum Motor Drive Failure.

042-324 ERROR — RAP IBT Drive Motor Failure.

042-325 ERROR — RAP Main Motor Failure.

042-326 ERROR — RAP Belt Home Position too long.

042-327 ERROR — RAP Belt Position Failure.

042-328 ERROR — RAP Belt Edge Sensor Failure.

042-330 ERROR — RAP Fuser Exhaust Fan Failure.

042-331 ERROR — RAP Blower Motor Fan Failure.

042-600 ERROR — RAP Belt Walk Failure.

042-601 ERROR — RAP Belt Edge Learn Failure.

042-602 ERROR — RAP Belt Edge Check Failure.

042-603 ERROR — RAP Suction Filter Life End Failure.

045-310 ERROR — RAP Image Ready NG.

045-311 ERROR — RAP Controller Comm Failure.

045-312 ERROR — RAP Driver Connect Failure.

047-210 ERROR — RAP OCT Offset Failure.

047-310 ERROR — RAP MCU-Finisher Communication Failure.

061-310 ERROR — RAP Clapper 1 Failure.

061-311 ERROR — RAP Clapper 2 Failure.

061-313 ERROR — RAP SOS Long Failure Magenta.

061-315 ERROR — RAP SOS Long Failure Black.

061-317 ERROR — RAP SOS Short Failure.

061-319 ERROR — RAP SOS Short Failure Black.

061-320 ERROR — RAP Polygon Motor Failure.

061-321 ERROR — RAP ROS Motor Failure.

22 Problem Solving

Error Code

072-210

[Cause]

[Remedy] Confirm the paper loading condition for Tray 2, and then switch off the machine power,

072-212

[Cause]

[Remedy] Contact our Customer Support Center. You can use a tray other than Tray 2.

073-210

[Cause]

[Remedy] Confirm the paper loading condition for the tray, and then switch off the machine

073-212

[Cause]

[Remedy] Contact our Customer Support Center. You can use a tray other than Tray 3.

075-210

[Cause]

075-211

[Remedy] Confirm the paper loading condition for the tray, and then switch off the machine

077-311

[Cause]

077-312

[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch

077-320

22

077-325

[Cause]

077-326

[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch

077-332

077-333

077-344

[Cause]

077-345

[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch

077-348

077-349

077-350

077-351

078-215

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch

078-219

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch

078-222

[Cause]

078-223

[Remedy] Switch off the machine power, make sure that the touch screen is blank, and then switch

836

Cause and Remedy

Tray 2 malfunction

make sure that the touch screen is blank, and then switch on the machine power. If the

error still is not resolved, contact our Customer Support Center. You can use a tray other

than Tray 2.

Tray 2 malfunctioned

Tray 3 malfunction

power, make sure that the touch screen is blank, and then switch on the machine power.

If the error still is not resolved, contact our Customer Support Center. You can use a tray

other than Tray 3.

Tray 3 malfunction

Tray 5 malfunction

power, make sure that the touch screen is blank, and then switch on the machine power.

If the error still is not resolved, contact our Customer Support Center.

An error occurred.

on the machine power. If the same message is displayed again, contact our Customer

Support Center.

An error occurred in the machine.

on the machine power. If the same message is displayed again, contact our Customer

Support Center.

An error occurred in the machine.

on the machine power. If the error still is not resolved, contact our Customer Support

Center.

An error occurred in Tray 6.

on the machine power. If the error still is not resolved, contact our Customer Support

Center.

An error occurred in Tray 6.

on the machine power. If the error still is not resolved, contact our Customer Support

Center.

An error occurred in HCF.

on the machine power. If the error still is not resolved, contact our Customer Support

Center.

Xerox WorkCentre 6015 - внешний вид

Xerox WorkCentre 6015 — внешний вид

Не смотря на заголовок, инструкция подходит и для Xerox Phaser 6000 / 6010. Отличие только в снятии ряда элементов кожуха.  Принтер изначально создавался как одноразовый, поэтому и разбор принтера осуществляется долго и нудно. Вообще, разбор и ремонт аппарата — это что-то среднее между ремонтом телефона или ремонтом часов. То есть, если раньше вам доводилось самостоятельно разбирать часы, а потом вы не могли их собрать, то лучше и не начинайте самостоятельный ремонт этого аппарата. Из инструментов понадобится плоская и крестовая отвертка.

Этап №1 Снятие элементов кожуха

rx-6015-2

Декоративная накладка

rx-6015-2-2Прежде всего необходимо снять элементы кожуха. У большинства принтеров и МФУ разбор начинается с задней части. Но в новой линейке домашних принтеров Xerox 6000/3010 разбор начинается именно с передней части (как в canon 4018). Для начала отщелкиваем  синюю декоративную накладку (она полностью держится на пластиковых защелках).  По-первой, панель отщелкивали с помощью плоской отвертки, но в последующих ремонтах просто руками.

rx-6015-3

Откидной лоток

rx-6015-3-2

Фиксирующие шурупы

Перед снятием передней панели полностью, нужно удалить откидной лоток для бумаги и открутить фиксирующие шурупы. Лоток отсоединяется очень просто: для этого просто отожмите его с одного края и выщелкните . После того, как отсоедините лоток, станут доступны два фиксирующих шурупа, которые необходимо открутить.

Отщелкиваем перенюю панель

Переняя панель

rx-6015-4-2

Вид МФУ со снятой передней панелью

После того, как шурупы были успешно выкручены, потянув за край отщелкните переднюю панель. Кстати, в аппарате передние панели играю сугубо декоративные функции, и печать вполне успешно может осуществляться и со снятыми панелями (что весьма полезно во время тестирования принтера, после устранения недостатков).

Снимаем левую панель

Левая панель

Основные фиксирующие защелки

Основные фиксирующие защелки

Теперь демонтируйте левую боковую панель. Панель полностью фиксируется на защелках, без шурупов. Рекомендуем  сначала отщелкнуть нижние защелки (см. фото справа), так как именно они являются основными фиксирующими элементами. Внимание!! Отщелкивая панель, будьте предельно аккуратны и внимательны, так как сразу за левой панелью скрывается плата форматора, которую по неосторожности можно повредить.

Отсоединяем провода и шлейфы сканера от форматера

Провода и шлейфы сканера от форматора

Откручиваем  провод заземления

Провод заземления

Далее необходимо демонтировать верхний блок сканера. Для этого необходимо отсоединить от платы форматора провода и шлейфы, идущие на сканер. Выдерните два шлейфа, идущие на линейку сканирования и блок АДФ,  далее отсоедините   кабель панели управления и открутите черный провод заземления.  Отсоединяя провода и шлейфы, не прилагайте излишнее усилие. Это может привести к поломке разъемов.

Левый кронштейн сканера

Левый кронштейн сканера

Демонтируем блок сканера

Демонтаж блока сканера

Отсоединив провода, идущие к блоку сканера, приступаем к снятию блока сканера. Для начала отщелкните левый и правый кронштейны,  удерживающие сканер, и, подняв сканер вверх, извлеките его. Внимание!! Вынимая сканер,  будьте  предельно внимательны, не повредите провода и шлейфы.  Лучше всего при демонтаже сканера привлечь на помощь еще одного человека.

Откручиваем фиксирующие шурупы удерживающие верхнюю часть корпуса

Извлечение фиксирующих шурупов

Демонтируем верхнюю часть

Демонтаж верхней части

Снятие блока сканера, пожалуй, самая трудоемкая процедура. Отсоедините верхнюю  часть корпуса. Для этого открутите четыре фиксирующих шурупа и извлеките его, потянув вверх.  Демонтируя верхнюю часть корпуса, обратите внимание как он посажен (это несколько облегчит последующую сборку).

Отсоединяем провод датчика закрытия дверцы

Извлечение провода датчика закрытия дверцы

Кабель датчика закрытия дверцы

Кабель датчика закрытия дверцы

Далее необходимо снять заднюю часть аппарата. Прежде чем это сделать, нужно отсоединить кабель датчика закрытия дверцы от платы блока питания.  Внимание!! Вытаскивая кабели из разъемов,   старайтесь запоминать, куда именно они были воткнуты и как были уложены.  Извлекая провод из проложенной трассы, постарайтесь не повредить уложенный параллельно с ним шлейф.

Откручиваем четыре  шурупа фиксирующих заднюю стенку

Шурупы, фиксирующие заднюю стенку

Извлекаем заднюю стенку

Извлечение задней стенки, обратите внимание на защелки слева

Крепление датчиков к кожуху — не самый лучший вариант и, как правило, производители так не поступают. Однако, учитывая тот факт, что принтер изначально разрабатывался как одноразовый, то  разработчикам это простительно. Отсоединив кабель датчика, открутите фиксирующие шурупы и извлеките заднюю стенку. Внимание!! Задняя стенка фиксируется не только на шурупах, но и на весьма жестких боковых защелках.

Извлекаем силовой кабель узла термозакрепления

Извлечение силового кабеля узла термозакрепления

Выщелкиваем боковую декоративную крышку

Боковая декоративная крышка

Осталось снять последнюю часть корпуса  — правую боковую стенку. Прежде чем приступить к демонтажу правой стенки, нужно извлечь из блока питания силовой разъем, идущий на печку, так как его трасса пролегает через боковую стенку.   Далее отщелкните боковую декоративную крышку  (естественно, предварительно удалив  все  картриджи).

Откручиваем шурупы выделенные маркером

Шурупы, выделенные маркером

Выщелкиваем черный держатель

Черный держатель

Открутите фиксирующие шурупы (но только те, которые на фото обведены маркером!). Шурупы, которые не обведены, относятся к блоку ксерографии и их пока откручивать не нужно. Далее отщелкните черный держатель. Внимание!! Держатель отщелкивается с трудом, и сначала создается ощущение, что он прикручен скрытым шурупом.

Отсоединяем правую боковину, потянув за правый край

Снятие правой боковины

Внимание будьте предельно аккуратны и не повредите провода

Внимание!!! будьте предельно аккуратны и не повредите провода

Приступаем к демонтажу последней части кожуха. Эта часть фиксируется только на шурупах. Поэтому после того, как открутили шурупы, отсоедините правую боковину, потянув за правый край. Внимание!! Правая боковина содержит механизм подкачки тонера, поэтому при извлечении будьте предельно аккуратны и не повредите провода.

Извлекаем провода из проложенной трассы

Извлечение проводов из проложенной трассы

Извлекаем провода из разъемов на плате.

Извлечение проводов из разъемов на плате.

Отсоединив правую боковину, нужно извлечь провода  из  проложенной  трассы  и вытащить провода  из  разъемов. Извлечение  проводов из разъемов — это целое искусство, требующее немалой сноровки.  Поэтому, если какой либо провод не вытаскивается,  не нужно выдирать его с мясом, а просто включите смекалку. На этом снятие кожуха закончено, но это еще только самое начало.  Как в мультике «Не готово? Что ж такого – стрижка только начата!»

Загрузка…

Содержание

  • 1 Ошибка 092-910 на принтерах Xerox WorkCentre 5024
  • 2 Треск при работе WC 6015
    • 2.1 Треск в узле ксерографии
    • 2.2 Треск Xerox WC 6015 в области печки
  • 3 Ошибка 024-360
  • 4 Ремонт контактной группы картриджей
  • 5 Ошибка 092-651
    • 5.1 Подкоды ошибки 092-651
  • 6 WC 6015 не печатает с компьютера
  • 7 Треск при работе WC 6015
    • 7.1 Треск в узле ксерографии
    • 7.2 Треск Xerox WC 6015 в области печки
  • 8 Major Causes of the error code 024-747 of Xerox printers
  • 9 Ремонт МФУ Xerox WC 6015
  • 10 WC 6015 не печатает с компьютера
  • 11 Замятие бумаги WC 6015
  • 12 Как сбросить ошибку 092-910?

Ошибка 092-910 на принтерах Xerox WorkCentre 5024

Ошибка 092-910 в Xerox WorkCentre 5024 возникает по разным причинам:

  • выход из строя датчика плотности тонера ATC;
  • отсутствие тонера в картридже;
  • проблемы с барабанным блоком и так далее.

Если чистка датчика ATC, а также замена расходных материалов не решили проблему, процесс печати может остановиться из-за поломки основной платы или ее отдельных компонентов.

Треск в узле ксерографии

В другом МФУ Xerox WC 6015 был слышен громкий треск при включении и работе. Пришлось разбирать МФУ еще дальше.

Сильный треск был вызван засорением пути отработанного тонера синим цветом. После тщательной очистки спрессованного тонера, превратившегося в камень, потрескивание исчезло. Отработанный тонер начал поступать в картридж.

Треск Xerox WC 6015 в области печки

Трещина в районе печки означает, что шестерни буксуют. В Xerox WC 6015 такое скорее всего, если сломалось крепление для плиты. При такой неисправности шестерня духовки не прижимается к шестерне редуктора принтера. Поэтому происходит проскальзывание и сильный треск.

Духовка в этом МФУ крепится двумя винтами сзади. А снизу печка цепляется к основанию с помощью полукруглых железных стопоров.

Если пробка отсутствует, печь не выдержит. В нашем случае полукруглая пробка была отломана.

Ошибка 024-360

Снова разберите весь принтер и проверьте разъемы на целостность и правильность соединения. Особенно тщательно проверьте контактные концы кабелей. Если они повреждены, отремонтируйте.

Ремонт контактной группы картриджей

Для ремонта разъема необходимо разобрать МФУ, снять разъемную группу и отремонтировать поврежденную контактную пластину.

Ошибка 092-651

Расшифровка субкодов не найдена. Особенностью ошибки 092-651 является то, что после этой ошибки принтер не перекачивает тонер из картриджей в ксерограф, и простого выхода из этой ситуации, похоже, нет.

Первая причина ошибки 092-651 — загрязнение датчиков CTD, расположенных на задней панели принтера под лентой переноса. CTD — датчик плотности цветного тонера. То есть это датчики плотности тонера для калибровки цвета в каждом цветном лазерном принтере. Они расположены за лентой переноса. Для решения этой проблемы протираем датчики спиртом и перезагружаем МФУ.

Если проблема не устранена, перейдите к следующей процедуре.

Вторая причина заключается в том, что в ксерографическом блоке, который переносит тонер, не хватает проявителя. Этот вариант возникает, если вы заправляете картридж не тем тонером. Например, универсальный тонер Samsung. В этом случае проявитель уходит и принтер слабо печатает. Чтобы добавить проявитель в блок ксерографии, необходимо разобрать весь МФУ.

Третья причина – в ксерографическом блоке не хватает тонера одного цвета. Причиной может быть неисправный картридж. В нашем случае это была ошибка 092-651 код 2440000. Причина — дешевые китайские картриджи, выходное отверстие которых заклеено липкой бумагой. После удаления бумаги клей остался. После установки картриджей клей плотно пристал к уплотнительной резинке принтера. Иногда это происходит из-за того, что выпускное отверстие для тонера заблокировано.

Решение таково. При включении подавайте тонер вручную для каждого цвета, пока тонер не появится в ксерографическом блоке. При ее появлении принтер оживет и начнет самостоятельно выкачивать тонер.

Подкоды ошибки 092-651

Иногда ошибка 092-651 28f0000 возникает из-за плохого тонера. С этим кодом полностью отсутствуют цвета желтый, красный, синий при калибровке. Это просто черный.

Решение. Замена тонера в цветных картриджах. С помощью сервисного меню можно запустить моторы каждого картриджа отдельно. Но не более 3 секунд на каждую.

После этого все цвета будут отображаться, но могут возникать ошибки 092-651 2880000. Это действительно плохо. Скорее всего, код означает, что яркости черного недостаточно для калибровки. Это означает, что в ксерографическом блоке плохой тонер или недостаточно проявителя. Но мы не берем на заправку застройщика. Слишком много геморроя.

WC 6015 не печатает с компьютера

Очень типичная ситуация. При подключении Xerox WC 6015 к компьютеру с Windows 7 драйверы автоматически устанавливаются через Центр обновлений Windows. Потом пытаешься что-то напечатать и ничего не происходит — задания на печать никуда не уходят, даже ошибки не появляется.

Это связано с неправильным драйвером для Windows 7, а также, возможно, для Windows 8 и 10.

Решение: скачайте и установите драйвер с официального сайта Xerox (весит около 200 МБ). После установки оригинального драйвера принтер Xerox WC 6015, ранее не печатавший с компьютера, начал печатать под Windows 7 и Windows 10.

Треск при работе WC 6015

Треск в узле ксерографии

В другом МФУ Xerox WC 6015 был слышен громкий треск при включении и работе. Пришлось разбирать МФУ еще дальше.

Сильный треск был вызван засорением пути отработанного тонера синим цветом. После тщательной очистки спрессованного тонера, превратившегося в камень, потрескивание исчезло. Отработанный тонер начал поступать в картридж.

Треск Xerox WC 6015 в области печки

Трещина в районе печки означает, что шестерни буксуют. В Xerox WC 6015 такое скорее всего, если сломалось крепление для плиты. При такой неисправности шестерня духовки не прижимается к шестерне редуктора принтера. Поэтому происходит проскальзывание и сильный треск.

Духовка в этом МФУ крепится двумя винтами сзади. А снизу печка цепляется к основанию с помощью полукруглых железных стопоров.

%D0%BA%D1%80%D0%B5%D0%BF%D0%BB%D0%B5%D0%BD%D0%B8%D0%B5-%D0%BF%D0%B5%D1%87% D0%BA%D0%B8-WC-6015.jpg

Если пробка отсутствует, печь не выдержит. В нашем случае полукруглая пробка была отломана.

Ремонт производился следующим образом.

%D1%80%D0%B5%D0%BC%D0%BE%D0%BD%D1%82-%D0%BA%D1%80%D0%B5%D0%BF%D0%BB%D0%B5% D0%BD%D0%B8%D0%B5-%D0%BF%D0%B5%D1%87%D0%BA%D0%B8-Xerox-WC-6015.jpg

Полукруг не нужен.

руководство пользователя принтера Код ошибки Причина и...

Major Causes of the error code 024-747 of Xerox printers

Ошибка с кодом ошибки принтера Xerox 024-747 может быть вызвана повреждением системных файлов Windows. Поврежденные системные файлы представляют реальную опасность для вашего компьютера. Есть много событий, которые показывают результат в ошибках системных файлов. Другими причинами этой ошибки являются неполная установка, неправильное определение оборудования, незавершенный процесс установки. Это происходит, если ваш компьютер обнаружен в результате атаки вредоносного ПО. Неправильное завершение может вызвать эту ошибку. Все вышеперечисленные действия могут привести к удалению или повреждению записей в системных файлах Windows. Этот поврежденный системный файл приведет к отсутствию и неправильному подключению информации и файлов, необходимых для правильной работы приложения.

Ремонт МФУ Xerox WC 6015

%D0%A0%D0%B5%D0%BC%D0%BE%D0%BD%D1%82-%D0%9C%D0%A4%D0%A3-Xerox-WC-6015.jpg

WC 6015 не печатает с компьютера

Очень типичная ситуация. При подключении Xerox WC 6015 к компьютеру с Windows 7 драйверы автоматически устанавливаются через Центр обновлений Windows. Потом пытаешься что-то напечатать и ничего не происходит — задания на печать никуда не уходят, даже ошибки не появляется.

Это связано с неправильным драйвером для Windows 7, а также, возможно, для Windows 8 и 10.

Решение: скачайте и установите драйвер с официального сайта Xerox (весит около 200 МБ). После установки оригинального драйвера принтер Xerox WC 6015, ранее не печатавший с компьютера, начал печатать под Windows 7 и Windows 10.

Замятие бумаги WC 6015

МФУ Xerox WC 6015 пришел в ремонт с постоянным сообщением о замятии бумаги, бумаги нигде не было.

После разборки устройства добираемся до датчика бумаги. Фактический датчик прохождения бумаги расположен сзади и показан стрелкой.

%D0%94%D0%B0%D1%82%D1%87%D0%B8%D0%BA-%D0%BF%D1%80%D0%BE%D1%85%D0%BE%D0%B6% D0%B4%D0%B5%D0%BD%D0%B8%D1%8F-%D0%B1%D1%83%D0%BC%D0%B0%D0%B3%D0%B8-Xerox-WC-6015 .jpg

Замените поврежденный датчик. На этом ремонт МФУ Xerox завершен.

Второй датчик находится в блоке крепления.

Как сбросить ошибку 092-910?

Простой замены изношенного блока фотокондуктора или использованного картриджа иногда недостаточно для сброса ошибки 092-910 .

Для завершения операции необходимо войти в сервисное меню принтера Xerox 5024 и выполнить следующий алгоритм действий:

ксерокс-5024-300x247.jpg

  1. включить устройство;
  2. зажать кнопку с цифрой «0» на 5 секунд, не отпуская ее, нажать кнопку «Старт»;
  3. введите набор цифр «6789» и снова нажмите «Старт»;
  4. после открытия сервисного меню набрать «752», завершить комбинацию кнопкой «Старт»;
  5. затем вызовите «059» — «Старт»;
  6. на экране должна появиться цифра «1», нажмите «Старт» — «000» — «Старт»;
  7. когда появится подтверждение сброса ошибки «ОК», зажать цифру «0» на 5 секунд, не отпуская кнопку, нажать «Старт».

После перезапуска машина должна запуститься без отображения ошибки 092-910 .

Датчики плотности цветного тонера (CTD) измеряют оптическую плотность тонера, нанесенного на маркировочный блок во время калибровки в процессе печати. Датчик установлен с каждой стороны маркерного блока. Это обеспечивает одинаковую плотность тонера по всей длине ленты. Для достижения оптимального качества печати принтер проверяет работу датчиков CTD в начале каждого цикла калибровки. Датчики CTD следует очищать, когда датчик CTD выходит из строя, или на панели управления появляется сообщение, или в меню Setup
принтер предоставляет эту инструкцию.

Если тонер попал на кожу или одежду, не удаляйте его горячей водой или моющими средствами. Использование горячей воды приведет к тому, что тонер прилипнет и его будет трудно удалить. Если тонер попал на кожу или одежду, стряхните его, сдуйте или смойте холодной водой с мылом.

Чтобы очистить датчики CTD:

  • Выключите принтер и выньте шнур питания из розетки.
  • откройте заднюю крышку, нажав на защелку.
  • Очистите датчики CTD, протерев отверстия чистым сухим ватным тампоном.
  • Не прикасайтесь к отмеченной области на нагревательном ролике фьюзера или рядом с ним. Вы можете обжечься.

Источники

  • https://kodyoshibok03.ru/oshibka-092-651-kod-2110000/
  • https://shamrin.ru/092-910-ochistite-datchik-ctd/
  • https://manualza.ru/xerox/d110/czbn181
  • https://errorcode0x.com/fix-xerox-printer-error-code-024-747/

[свернуть]

  1. 02-06-2017


    #1

    Mukasa is offline


    Senior Tech

    100+ Posts


    Rep Power
    0

    xerox 700 error code 077-326

    Hello guys,
    This machine was working fine with all A4 paper weights though it was showing error code 077-120 . Could not copy heavy weight A3 paper it could jam at the 2nd BTR, i serviced the registration area only, testing the machine again it brought an error 077-326. The machine gets ready to copy and print but sending a job it runs a bit then shows error code 077-326. what can i do next.

    Regards
    Muks


  2. 02-07-2017


    #2

    prismtech is offline


    Senior Tech

    100+ Posts

    xerox 700 error code 077-326


    Rep Power
    22

    Re: xerox 700 error code 077-326

    Procedure
    Check the condition of the IBT belt. The IBT belt is in proper condition without being damaged.
    Y N
    Replace the IBT Belt (PL 7.3).
    Enter dC330 [042-018 IBT Steering Motor (CW) Low Current]. The IBT Steering Motor
    comes ON.
    Y N
    Go to OF 99-9 and troubleshoot the IBT Steering Motor, BSD 9.19 (PL 7.4).
    Select [042-200 Belt Home Position Sensor]. The IBT Belt Home position can be detected.
    Y N
    Go to OF 99-1 and troubleshoot the Transfer Belt Home Sensor, BSD 9.20 (PL 7.5).
    Select [094-202 Post 2nd BTR Sensor]. Place paper in front of the Post 2nd BTR Sensor. The
    display changes.
    Y N
    Go to OF 99-1 and troubleshoot the Post 2nd BTR Sensor BSD 9.28 (PL 7.9).
    Replace the MCU PWB (PL 11.1).


  3. 02-07-2017


    #3

    Mukasa is offline


    Senior Tech

    100+ Posts


    Rep Power
    0

    Re: xerox 700 error code 077-326

    [QUOTE=prismtech;550193]Procedure
    Check the condition of the IBT belt. The IBT belt is in proper condition without being damaged.
    Y N
    Replace the IBT Belt (PL 7.3).
    Enter dC330 [042-018 IBT Steering Motor (CW) Low Current]. The IBT Steering Motor
    comes ON.
    Y N
    Go to OF 99-9 and troubleshoot the IBT Steering Motor, BSD 9.19 (PL 7.4).
    Select [042-200 Belt Home Position Sensor]. The IBT Belt Home position can be detected.
    Y N
    Go to OF 99-1 and troubleshoot the Transfer Belt Home Sensor, BSD 9.20 (PL 7.5).
    Select [094-202 Post 2nd BTR Sensor]. Place paper in front of the Post 2nd BTR Sensor. The
    display changes.
    Y N
    Go to OF 99-1 and troubleshoot the Post 2nd BTR Sensor BSD 9.28 (PL 7.9).
    Replace the MCU PWB (PL 11.1).[/QUO

    Thanks i will get back to you after doing what you have told me.


  4. 02-08-2017


    #4

    Mukasa is offline


    Senior Tech

    100+ Posts


    Rep Power
    0

    Re: xerox 700 error code 077-326

    Quote Originally Posted by prismtech
    View Post

    Procedure
    Check the condition of the IBT belt. The IBT belt is in proper condition without being damaged.
    Y N
    Replace the IBT Belt (PL 7.3).
    Enter dC330 [042-018 IBT Steering Motor (CW) Low Current]. The IBT Steering Motor
    comes ON.
    Y N
    Go to OF 99-9 and troubleshoot the IBT Steering Motor, BSD 9.19 (PL 7.4).
    Select [042-200 Belt Home Position Sensor]. The IBT Belt Home position can be detected.
    Y N
    Go to OF 99-1 and troubleshoot the Transfer Belt Home Sensor, BSD 9.20 (PL 7.5).
    Select [094-202 Post 2nd BTR Sensor]. Place paper in front of the Post 2nd BTR Sensor. The
    display changes.
    Y N
    Go to OF 99-1 and troubleshoot the Post 2nd BTR Sensor BSD 9.28 (PL 7.9).
    Replace the MCU PWB (PL 11.1).

    Hello Prismtech
    I would like to get a BSD related to the fault 077-326 xerox 700 .
    I changed the the IBT Assy still error didn’t clear, the machine gets ready to copy/ print but when you send a job it runs a bit then error 077-326.
    Please help.


  5. 02-09-2017


    #5

    Tonersniffer is offline


    Trusted Tech

    50+ Posts

    Tonersniffer's Avatar


    Rep Power
    24

    Re: xerox 700 error code 077-326

    077-326 Regi NIP Fail

    BSD On

    CH8.9b Registration Drive (3 0f 3)

    Description

    No output is made from Regi NIP Release Home SNR within specified time from the start of Regi NIP Release Mot operation.

    Initial Action

    • Clean the SNR
    • Remove jammed paper

    CC Code to Check

    • [077-031] Regi NIP Release Mot
    • [077-032] Regi NIP Release Mot
    • [077-033] Regi NIP Release Mot
    • [077-107] Regi NIP Release Home SNR

    Check Items

    • Check the following for an open wire, short or poor contact:
      • Approx +24 VDC between PH Driver PWB P468-A4 to GND
      • Approx +24 VDC between PH Driver PWB P468-A7 to GND
      • Regi NIP Release Mot harness between P468 on PH Driver PWB to P/J274 on Regi NIP Release Mot for an open wire, short or poor contact
      • Regi NIP Release Mot harness between P401 on MCU PWB to P461 on PH Driver PWB for an open wire, short or poor contact
      • If the results of the above checks are good, replace the Regi NIP Release Mot ( PL 4.8).
    • Check the following for an open wire, short or poor contact:
      • Approx +5 VDC between IOT Driver PWB P431-A9 to GND
      • Approx +5 VDC between IOT Driver PWB P431-A8 to P431-A10
      • Regi NIP Release Home SNR harness between P431-A9 on IOT Driver PWB to P/J117-2 on Regi NIP Release Home SNR for an open wire, short or poor contact
      • Regi NIP Release Home SNR harness between P431-A8, A10 on IOT Driver PWB to P/J117-1, 3 on Regi NIP Release Home SNR for an open wire, short or poor contact
      • If the results of the above checks are good, replace the Regi NIP Release Home SNR ( PL 4.7).
    • Replace the following:
      • PH Driver PWB ( PL 11.3)
        077-120 RAP

        BSD On


        CH9.28 2nd Transfer and Cleaning (3 of 3)

        Description

        Post 2nd BTR Sensor On JAM

        I havent seen these issues. This all I have.

        hope this helps


        Tonersniffer

      • Sounds like you need to check reg unit again. Motor/ sensor unplugged? gear not driving? then get back to original problem. On original problem, did you check to make it showed the proper paper size and orientation?

    Last edited by Tonersniffer; 02-09-2017 at 02:03 PM.


  6. 02-14-2017


    #6

    Mukasa is offline


    Senior Tech

    100+ Posts


    Rep Power
    0

    Re: xerox 700 error code 077-326

    Quote Originally Posted by Tonersniffer
    View Post

    077-326 Regi NIP Fail

    BSD On

    CH8.9b Registration Drive (3 0f 3)

    Description

    No output is made from Regi NIP Release Home SNR within specified time from the start of Regi NIP Release Mot operation.

    Initial Action

    • Clean the SNR
    • Remove jammed paper

    CC Code to Check

    • [077-031] Regi NIP Release Mot
    • [077-032] Regi NIP Release Mot
    • [077-033] Regi NIP Release Mot
    • [077-107] Regi NIP Release Home SNR

    Check Items

    • Check the following for an open wire, short or poor contact:
      • Approx +24 VDC between PH Driver PWB P468-A4 to GND
      • Approx +24 VDC between PH Driver PWB P468-A7 to GND
      • Regi NIP Release Mot harness between P468 on PH Driver PWB to P/J274 on Regi NIP Release Mot for an open wire, short or poor contact
      • Regi NIP Release Mot harness between P401 on MCU PWB to P461 on PH Driver PWB for an open wire, short or poor contact
      • If the results of the above checks are good, replace the Regi NIP Release Mot ( PL 4.8).

    • Check the following for an open wire, short or poor contact:
      • Approx +5 VDC between IOT Driver PWB P431-A9 to GND
      • Approx +5 VDC between IOT Driver PWB P431-A8 to P431-A10
      • Regi NIP Release Home SNR harness between P431-A9 on IOT Driver PWB to P/J117-2 on Regi NIP Release Home SNR for an open wire, short or poor contact
      • Regi NIP Release Home SNR harness between P431-A8, A10 on IOT Driver PWB to P/J117-1, 3 on Regi NIP Release Home SNR for an open wire, short or poor contact
      • If the results of the above checks are good, replace the Regi NIP Release Home SNR ( PL 4.7).

    • Replace the following:
      • PH Driver PWB ( PL 11.3)
        077-120 RAP

        BSD On


        CH9.28 2nd Transfer and Cleaning (3 of 3)

        Description

        Post 2nd BTR Sensor On JAM

        I havent seen these issues. This all I have.

        hope this helps


        Tonersniffer

      • Sounds like you need to check reg unit again. Motor/ sensor unplugged? gear not driving? then get back to original problem. On original problem, did you check to make it showed the proper paper size and orientation?

    Hello thanks guys,
    When i changed the Regi NIP Release Mot the fault code cleared ok.
    All trays are working fine except tray 5 jams paper 300gm heavy weight at the registration rollers .
    Is there any settings i have to do?

    Rgds
    Muks