Xerox docucolor 242 ошибка 061 343

  • 002-770 RAP Insufficient HDD capacity while processing the job
    template within a job.003-318 RAP IIT software failure.003-319 RAP
    IIT Video Driver Detection Fail.003-320 RAP IIT-ESS Communication
    Fail 1.003-321 RAP IIT-ESS Communication Fail 2.003-322 RAP IIT-ESS
    Communication Fail 3.003-323 RAP IIT-ESS Communication Fail
    4.003-324 RAP IIT-ESS Communication Fail 5.003-325 RAP IIT-ESS
    Communication Fail 6.003-326 RAP IIT-ESS Communication Fail
    7.003-327 RAP IIT-ESS Communication Fail 8.003-328 RAP IIT-ESS
    Communication Fail 9.003-329 RAP IIT-ESS Communication Fail
    10.003-330 RAP IIT-ESS Communication Fail 11.003-331 RAP IIT-ESS
    Communication Fail 12.003-332 RAP IIT-ESS Communication Fail
    13.003-333 RAP IIT-ESS Communication Fail 14.003-334 RAP IIT-ESS
    Communication Fail 15.003-335 RAP IIT-ESS Communication Fail
    16.003-336 RAP IIT-ESS Communication Fail 17.003-337 RAP IIT-ESS
    Communication Fail 18.003-338 RAP IIT-ESS Communication Fail
    19.003-339 RAP IIT-ESS Communication Fail 20.003-340 RAP IIT-ESS
    Communication Fail 21.003-341 RAP IIT-ESS Communication Fail
    22.003-342 RAP IIT-ESS Communication Fail 23.003-343 RAP IIT-ESS
    Communication Fail 24.003-344 RAP Power on hotline failure.003-345
    RAP X PIO Unmatch Fail 1.003-346 RAP X PIO Unmatch Fail 2.003-750
    RAP Book Duplex-Insufficient Docs.003-751 RAP Under PANTHER
    Capacity (Scan).003-752 RAP This status code is displayed if 600dpi
    cannot be scanned (DADF).003-753 RAP This status code is displayed
    if over 300dpi cannot be scanned (DADF).003-754 RAP S2X Recoverable
    Error.003-755 RAP S2X Command Error.003-757 RAP This status code is
    displayed if over 400dpi cannot be scanned (DADF).003-760 RAP Scan
    Settings Error.003-761 RAP Incorrect Paper Tray Size.003-763 RAP
    Adjustment Chart Not Found.003-764 RAP Adjustment Chart Not
    Found.003-780 RAP Scan Image Compression Error.003-795 RAP AMS
    Limit Error.003-940 RAP DAM Memory is insufficient.003-942 RAP
    Document Size Error.003-944 RAP Image Repeat Count Fail.003-946 RAP
    Copy Vertical/Horizontal Difference (APS).003-947 RAP Replaced
    Original Count Error.003-948 RAP Replaced Original Mismatch.003-952
    RAP Return Documents Color mismatch.003-955 RAP Documents Size
    Exchange Error.003-956 RAP Documents Size Unknown Error.

  • 003-963 RAP No APS Object Tray.003-965 RAP ATS/APS No Paper.
    There is no paper in the trays that can be selected with
    APS.003-966 RAP AATS/APS No Destination Error.003-968 RAP Punch
    Position Error.003-969 RAP Punch Size Error.003-972 RAP Maximum
    Stored Page Over Flow.003-973 RAP Every Direction
    Difference.003-974 RAP Next Original Specification.003-977 RAP
    Document Miss Match (Multi Scan).003-978 RAP Color Document
    Mismatch (Multi Scan).003-980 RAP Staple Position Error.003-981 RAP
    Staple Size Error.003-982 RAP IITsc HDD Access Error.005-121 RAP
    DADF Feed Sensor ON Jam.005-122 RAP DADF Simplex/Side 1 Pre Reg
    Sensor ON Jam.005-123 RAP DADF Simplex/Side 1 Reg Sensor ON
    Jam.005-124 RAP DADF Lead Reg Sensor ON Jam.005-125 RAP DADF Reg
    Sensor OFF Jam.005-126 RAP DADF Out Sensor ON Jam.005-127 RAP DADF
    Out Sensor OFF Jam.005-128 RAP DADF Exit Sensor 1 ON Jam (Simplex
    Mode).005-129 RAP DADF Exit Sensor 1 OFF Jam (Simplex Mode).005-130
    RAP DADF Invert Sensor ON Jam (Duplex Mode).005-131 RAP DADF Invert
    Sensor On Jam (Inverting).005-132 RAP DADF Invert SNR on Jam
    2.005-133 RAP DADF Invert Sensor OFF Jam.005-134 RAP DADF Invert
    SNR off Jam (Inv).005-135 RAP DADF Pre Reg Sensor ON Jam
    (Invert).005-136 RAP DADF Reg Sensor ON Jam (Invert).005-137 RAP
    DADF Exit Sensor 2 ON Jam.005-138 RAP DADF Exit Sensor 1 ON
    Jam.005-139 RAP DADF Invert SNR off Jam.005-141 RAP DADF Feed
    Sensor OFF Jam.005-142 RAP DADF Exit Sensor 1 OFF Jam (Duplex
    Mode).005-143 RAP DADF Exit Sensor 2 OFF Jam.005-144 RAP DADF Too
    First Pre Reg Sensor ON Jam.005-145 RAP DADF Reg Sensor Off Jam
    (Invert).005-146 RAP DADF Pre Reg Sensor Off Jam.005-147 RAP DADF
    Pre Reg Sensor Off Jam (Invert).005-150 RAP DADF Feed Sensor OFF
    Jam (Perforated Original Mode).005-151 RAP DADF Pre Reg Sensor OFF
    Jam (Perforated Original Mode).005-152 RAP DADF Reg Sensor OFF Jam
    (Perforated Original Mode).005-153 RAP DADF Reg Sensor OFF Jam
    (Perforated Original Mode).005-154 RAP DADF Out Sensor OFF Jam
    (Perforated Original Mode).005-155 RAP DADF Exit Sensor 1 OFF Jam
    (Perforated Original Mode) (Simplex).005-156 RAP DADF Exit Sensor 1
    OFF Jam (Perforated Original Mode) (Duplex).005-157 RAP DADF Invert
    Sensor OFF Jam (Perforated Original Mode).005-158 RAP DADF Exit
    Sensor 2 OFF Jam (Perforated Original Mode).005-160 RAP DADF Tray
    Lift Up Fail (Document Set) (Within Job).005-190 RAP DADF Feed
    Motor Logic Jam.005-194 RAP Size Mismatch Jam on Slow Scan Mix
    Size.005-195 RAP Size Mismatch Jam on No Mix Size.

  • 005-196 RAP Size Mismatch Jam on No Mix Size.005-197 RAP
    Prohibit Combine Size Jam.005-198 RAP Too Short Size Jam.005-199
    RAP Too Long Size Jam.005-275 RAP DADF RAM Fail.005-280 RAP DADF
    EEPROM Fail.005-282 RAP DADF Tray Lift Up Fail (No
    Document).005-283 RAP DADF Stack Height Sensor Logic Fail.005-284
    RAP DADF APS Sensor Logic Fail.005-285 RAP DADF Nudger Lift Up
    Fail.005-286 RAP DADF Feed Out Sensor Fail.005-303 RAP DADF Tray
    Interlock is open.005-304 RAP Platen Interlock Open.005-305 RAP
    DADF Feeder Cover Interlock Open (Run).005-306 RAP DADF Tray
    Interlock Open (Run).005-308 RAP The DADF L/H Cover Interlock is
    open.005-309 RAP DADF L/H Cover Interlock Open (Run).005-906 RAP
    DADF Feed Sensor Static Jam.005-907 RAP DADF Pre Reg Sensor Static
    Jam.005-908 RAP DADF Reg Sensor Static Jam.005-909 RAP DADF Lead
    Reg Sensor Static Jam..005-910 RAP DADF Out Sensor Static
    Jam.005-911 RAP DADF Exit Sensor 1 Static Jam.005-912 RAP DADF Exit
    Sensor 2 Static Jam.005-913 RAP DADF Invert Sensor Static
    Jam.005-914 RAP DADF No. 1/2/3 APS Sensor Static Jam.005-915 RAP
    DADF No. 1 APS Sensor Static Jam.005-916 RAP DADF No. 2 APS Sensor
    Static Jam.005-917 RAP DADF No. 3 APS Sensor Static Jam.005-918 RAP
    DADF Invert Sensor 2 Static Jam.005-919 RAP DADF Tray Lift Up Fail
    (Document Set).005-940 RAP DADF No Original Fail.005-941 RAP DADF
    Not Enough Document.005-942 RAP DADF Tray Stack Over Fail.010-311
    RAP Fuser Heat Roll STS-1 Disconnection Fail. It was detected that
    fuser heat roll STS-1 disconnected.010-319 RAP Fuser NC Sensor
    Differential Amp Fail.010-320 RAP Heat Roll Over Heat Fail.010-321
    RAP Fuser Nip Fail.010-322 RAP Fuser NC Center Sensor Disconnection
    Fail. (Fuser Temperature Sensor Fail).010-323 RAP Fuser Rear Sensor
    Disconnection Fail. (Fuser Temperature Sensor Fail).010-324 RAP
    Fuser NVM Fail.010-326 RAP Wait Heat Roll Fuser On Time
    Fail.010-327 RAP Standby Heat Roll Fuser On Time Fail.010-330 RAP
    Fuser Motor Fail.010-420 RAP Fuser Assembly Life Near End.010-421
    RAP Fuser Assembly Life End.012-112 RAP Finisher Interface Entrance
    Sensor ON.012-113 RAP Booklet In Sensor ON Jam.012-114 RAP Booklet
    In Sensor OFF Jam.012-115 RAP Booklet Folder Roll Exit Sensor ON
    Jam.012-125 RAP Gate Sensor ON JAM: Finisher.

  • 012-132 RAP Finisher Transport Entrance Sensor ON Jam
    (Long).012-142 RAP Buffer Path Sensor ON Jam A.012-151 RAP Compile
    Exit Sensor OFF Jam.012-152 RAP Compile Exit Sensor ON Jam
    A.012-161 RAP Set Eject Jam.012-162 RAP Finisher Interface EXIT.
    Sensor ON Jam.012-171 RAP Top Tray Exit Sensor ON Jam A.012-172 RAP
    Top Tray Exit Sensor OFF Jam A.012-180 RAP Booklet Folder Roll Exit
    Sensor OFF Jam.012-211 RAP Stacker Tray Fail.012-212 RAP Stacker
    Tray Upper Limit Fail.012-213 RAP Stacker Tray Lower Limit
    Fail.012-221 RAP Tamper Home Sensor ON Fail.012-223 RAP Tamper Home
    Sensor OFF Fail.012-224 RAP Rear Tamper Home Sensor OFF
    Fail.012-225 RAP Booklet Tamper F Home Sensor ON Fail.012-226 RAP
    Booklet Tamper F Home Sensor OFF Fail.012-227 RAP Booklet End Guide
    Home Sensor OFF Fail.012-228 RAP Booklet End Guide Home Sensor ON
    Fail.012-229 RAP Booklet Tamper R Home Sensor ON Fail.012-230 RAP
    Booklet Tamper R Home Sensor OFF Fail.012-243 RAP Booklet Knife
    Home Sensor ON Fail.012-246 RAP Booklet Stapler Fail.012-247 RAP
    Side Regi Sensor OFF Fail.012-260 RAP Eject Clamp Up Sensor ON
    Fail.012-261 RAP Booklet Knife Folding SNR Fail.012-263 RAP
    Finisher Rear Tamper Home Sensor ON.012-264 RAP Booklet Drawer
    Broken Fail.012-265 RAP Booklet Knife Home Sensor OFF Fail.012-266
    RAP Booklet Compiler No Paper Sensor Fail.012-270 RAP Top Offset
    Home Sensor ON Fail: Finisher.012-271 RAP Top Offset Home Sensor
    OFF Fail: Finisher.012-282 RAP Eject Clamp Up Sensor OFF
    Fail.012-283 RAP Finisher Set Clamp Home Sensor ON Fail.012-284 RAP
    Finisher Set Clamp Home Sensor OFF Fail.012-291 RAP Stapler
    Fail.012-295 RAP Finisher Stapler Move Sensor On Fail.012-296 RAP
    Finisher Stapler Move Sensor OFF Fail.012-300 RAP Finisher Eject
    Cover Open (Compiler Cover).012-302 RAP Finisher Front Door
    Interlock Open.012-307 RAP Booklet Drawer Set Fail.012-320 RAP
    Punch Home Sensor ON Fail.012-321 RAP Punch Home Sensor OFF
    Fail.012-322 RAP Puncher Move Home Sensor OFF Fail.012-323 RAP
    Puncher Move Home Sensor On Fail.012-325 RAP Side Regi Home Sensor
    On Fail.012-330 RAP Decurler Cam Home Sensor OFF Fail.012-332 RAP
    Decurler Cam Home Sensor ON Fail.012-334 RAP Download Mode
    Fail.012-335 RAP Booklet Sub CPU Communication Fail.012-900 RAP
    Buffer Path Sensor Static Jam.012-901 RAP Finisher Paper Remains at
    H-Transport Entrance.

  • 012-902 RAP Finisher Paper Remains H-Transport Exit.012-903 RAP
    Compile Exit Sensor Static Jam.012-905 RAP Compile Tray No Paper
    Sensor Static Jam.012-907 RAP Top Tray Exit Sensor Static
    Jam.012-920 RAP Gate Sensor static JAM (to Top Tray) A:
    Finisher.012-932 RAP Gate SNR static JAM (to Stacker Tray)
    A.012-934 RAP Gate SNR static JAM (to Stacker Tray) C.012-935 RAP
    Finisher Paper Remains at Transport Entrance Sensor.012-936 RAP
    Paper Remain at Booklet In SNR A.012-949 RAP Finisher Punch DustBox
    Miss Set.013-902 RAP Booklet Compile No Paper Sensor Static
    Jam.013-903 RAP Booklet Folder Roll Exit Sensor Static Jam.016-210
    RAP Software Option Fail (HDD Not Exist).016-211 RAP Software
    Option Fail (System Memory Low Volume).016-212 RAP SW Option Fail
    (Page Memory Low).016-213 RAP SW Option Fail (Printer CARD Not
    Exist).016-215 RAP SW Option Fail (JPEG Board Not Exist).016-216
    RAP SW Option Fail (Ext Memory Not Exist).016-217 RAP SW Option
    Fail (Controller ROM not Printer kit).016-218 RAP Because PS Kit is
    not installed, XDOD functions cannot be fulfilled.016-219 RAP
    License is required (Printer Kit).016-220 RAP S2X Unrecoverable
    Error.016-221 RAP S2X Communication Error.016-222 RAP S2X Self-Diag
    Error.016-223 RAP SS2X SDRAM Error.016-224 RAP S2X PCI Reg
    Error.016-225 RAP S2X ROM CheckSum Error.016-226 RAP S2X IIT
    Connection Error.016-227 RAP S2X DDR Error.016-228 RAP S2X Image
    Processing Error.016-229 RAP SW Option Fail (FCW-UI Not
    Exist).016-311 RAP The scanner was not detected.016-315 RAP NIIT
    Interface Fail.016-316 RAP Page Memory Not Detected.016-317 RAP
    Page Memory Broken-Standard.016-318 RAP Page Memory
    Broken-Option.016-320 RAP A fatal error with doc conversion
    software was detected.016-322 RAP JBA Account Full.016-450 RAP SMB
    Host Name Duplicated.016-454 RAP DNS Renewal Failure of
    Dynamic.016-455 RAP SNTP Server Time Out.016-456 RAP SNTP Time
    Asynchronous.016-503 RAP SMTP Server Address Resolution
    Fail.016-504 RAP POP Server Address Resolution Fail.016-505 RAP POP
    Authentication Fail.016-600 RAP KO Authentication Locked.016-601
    RAP Illegal Access Detection.016-647 RAP With APS selected or with
    APS set up, there were no trays loaded with paper sizes for Auto
    Paper Selection.016-648 RAP Job with Booklet selected was
    discontinued because it had a cover with an image, a divider, or a
    blank page.016-701 RAP Out of ART EX Memory.

  • 016-702 RAP Out of Page Buffer.016-703 RAP Email to Invalid
    Box.016-704 RAP Mailbox is Full.016-705 RAP Secure Print
    Fail.016-706 RAP Max. User Number Exceeded.016-707 RAP Sample Print
    Fail.016-708 RAP HD Full by Annotation/Watermark Image.016-709 RAP
    ART EX Command Error.016-710 RAP Delayed Print Fail.016-711 RAP
    Tried to send data whose size is over the system data upper
    limit.016-712 RAP Under PANTHER Capacity (I-Formatter).016-713 RAP
    Security Box Password Error.016-714 RAP Security Box is not
    Enabled.016-716 RAP TIFF Data Overflow.016-718 RAP Out of PCL6
    Memory.016-719 RAP Out of PCL Memory.016-720 RAP PCL Command
    Error.016-721 RAP Other Error.016-722 RAP Job Cancel by Staple
    Position NG.016-723 RAP Job Cancel by Punch Position NG.016-724 RAP
    Complex Position Error of Staple and Punch.016-726 RAP PDL Auto
    Switch Fail.016-728 RAP Unsupported TIFF Data.016-729 RAP TIFF Data
    Size too Big.016-730 RAP Unsupported ART Command.016-731 RAP
    Invalid TIFF Data.016-732 RAP Form Not Registered.016-733 RAP
    Destination Address Resolution Error.016-734 RAP Simple
    Transmission report invocation error.016-735 RAP Updating Job
    Template.016-736 RAP Remote directory lock error. Lock directory
    creation failed.016-737 RAP Remote lock directory remove
    error.016-738 RAP PS Booklet Print Output Paper Size is
    illegal.016-739 RAP Mismatch between PS Booklet Doc and Output
    Paper.016-740 RAP PS Booklet Output Tray is incorrect.016-746 RAP
    Unsupported PDF File.016-748 RAP HD Full.016-749 RAP JCL Syntax
    Error.016-751 RAP PDF Error.016-752 RAP PDF Short of Memory.016-753
    RAP PDF Password Mismatched.016-754 RAP PDF LZW Not
    Installed.016-755 RAP PDF Print Prohibited.016-756 RAP
    Auditron-Prohibit Service.016-757 RAP Auditron-Invalid User.016-758
    RAP Auditron-Disabled Function.016-759 RAP Auditron-Reached
    Limit.016-760 RAP PS Decompose Failure.016-761 RAP FIFO
    Empty.016-762 RAP Print LANG Not Installed.016-764 RAP SMTP Server
    Connect Error.016-765 RAP SMTP Server HD Full.

  • 016-766 RAP SMTP Server File System Error.016-767 RAP Invalid
    E-mail Address.016-768 RAP Invalid Sender Address.016-769 RAP SMTP
    Server Unsupported DSN.016-771 RAP Scan Data Repository ERR.016-772
    RAP Scan Data Repository ERR.016-773 RAP Invalid IP Address.016-774
    RAP HD Full-Compression Convert.016-775 RAP HD Full-Image
    Convert.016-776 RAP Image Convert ERR.016-777 RAP HD Access
    ERR-Image Convert.016-778 RAP HD Full-Scan Image Convert.016-779
    RAP Scan Image Conversion Error.016-780 RAP HD Access ERR-Image
    Convert.016-781 RAP Scan Server Connect ERR.016-782 RAP Scan Server
    Login ERR.016-783 RAP Invalid Server Path.016-784 RAP Server Write
    ERR.016-785 RAP Server HD Full.016-786 RAP HD Full-Scan Write
    ERR.016-787 RAP Invalid Server IP ADD.016-788 RAP Retrieve to
    Browser Failed.016-789 RAP HD Full-Job Memory.016-791 RAP File
    Retrieve Fail.016-792 RAP Specified Job Not Found.016-793 RAP MF
    I/O HD Full.016-794 RAP Media Reader: Media No Insert.016-795 RAP
    Media Reader: Format Error.016-796 RAP Document insert operation
    error.016-797 RAP Media Reader: Image File Read Error.016-798 RAP
    No Trust Marking Option.016-799 RAP Print Instruction Fail.016-940
    RAP With Duplex Output selected, a size difference between side 1
    and side 2 was detected.016-941 RAP With Booklet selected,
    mixed-in-size/orientation pages with images were detected.016-942
    RAP After a duplexed page was deleted, a size difference between
    side 1 and side 2 was detected.016-943 RAP After a document or
    divider was inserted, a size difference between side 1 and side 2
    was detected.016-944 RAP Documents were merged, including the cover
    with an image, or a document with a divider.016-945 RAP A document
    unavailable for duplex print was inserted after a document
    available for Duplex was inserted.016-946 RAP A document or a
    divider was inserted after the cover or divider page.016-949 RAP
    The user inserted a documnet different in size/orientation from the
    page to be processed.016-981 RAP A failure in access to HDD.016-982
    RAP HDD Access Error 2.016-985 RAP Data Size Over Flow (Scan to
    Email).024-340 RAP IOT-ESS Communication Failure 1.024-341 RAP
    IOT-ESS Communication Failure 2.024-342 RAP IOT-ESS Communication
    Failure 3.

  • 024-343 RAP IOT-ESS Communication Failure 4.024-345 RAP IOT-ESS
    Communication Failure 5.024-346 RAP IOT-ESS Communication Failure
    6.024-347 RAP IOT-ESS Communication Failure 7.024-348 RAP IOT-ESS
    Communication Failure 8.024-349 RAP IOT-ESS Communication Failure
    9.024-350 RAP IOT-ESS Communication Failure 10.024-351 RAP IOT-ESS
    Communication Failure 11.024-352 RAP IOT-ESS Communication Failure
    12.024-353 RAP IOT-ESS Communication Failure 13.024-354 RAP IOT-ESS
    Communication Failure 14.024-355 RAP IOT-ESS Communication Failure
    15.024-356 RAP IOT-ESS Communication Failure 16.024-357 RAP IOT-ESS
    Communication Failure 17.024-358 RAP IOT-ESS Communication Failure
    18.024-359 RAP IOT-ESS Communication Failure 19.024-360 RAP IOT-ESS
    Initialization Failure.024-361 RAP Invalid IOT PaperSizeGroup
    Information.024-362 RAP Page Sync Illegal Start.024-363 RAP Page
    Sync Illegal Stop.024-364 RAP DMA Transfer Failure.024-365 RAP
    Overflow on the Loop Back Write.024-366 RAP JBIG Library Other
    Failure.024-367 RAP Decompress Other Failure.024-368 RAP PCI
    Error.024-370 RAP Marker Code Detect Failure.024-371 RAP IOT-ESS
    Communication Failure 21.024-372 RAP IOT-ESS Communication Failure
    22.024-373 RAP IOT-ESS Communication Failure 23.024-374 RAP Regi
    Con PLL Parameter Failure.024-375 RAP IOT-ESS Communication Failure
    24.024-600 RAP Billing master counter repair.024-601 RAP Billing
    backup counter #1 repair.024-602 RAP Billing backup counter #2
    repair.024-603 RAP SWKey master counter repair.024-604 RAP SWKey
    backup counter #1 repair.024-605 RAP SWKey backup counter #2
    repair.024-606 RAP Production Number/Serial Number Failure.024-746
    RAP Selected Paper Tray Parameter Mismatch.024-747 RAP Print
    Instruction Failure.024-910 RAP Tray 1 Size Mismatch.024-911 RAP
    Tray 2 Size Mismatch.024-912 RAP Tray 3 Size Mismatch.024-913 RAP
    Tray 4 Size Mismatch.024-914 RAP Tray 6 Size Mismatch.024-915 RAP
    Tray 7 Size Mismatch.024-917 RAP Stacker Tray Staple Set Over
    Count.024-919 RAP Face UP Tray Close.024-920 RAP Face Down Tray 1
    Paper FULL.024-922 RAP Face Down Tray 2 Paper FULL.024-923 RAP
    Operation Yellow Toner Empty.024-924 RAP Operation Magenta Toner
    Empty.

  • 024-925 RAP Operation Cyan Toner Empty.024-926 RAP Punch Dust
    Box Missing Set.024-927 RAP Offset Catch Tray Full Stack.024-930
    RAP Stacker Tray Full (Small Size Full).024-934 RAP Paper type
    mismatch.024-935 RAP Tray 1 Paper Mismatch.024-936 RAP Tray 2 Paper
    Mismatch.024-937 RAP Tray 3 Paper Mismatch.024-938 RAP OHP kind
    Mismatch at Tray 4 (Not White Frame OHP).024-939 RAP Transparency
    type mismatch (No white border).024-940 RAP Folder Tray Out of
    Place.024-941 RAP Folder Tray Full Stack.024-942 RAP Booklet Sheets
    Over Count.024-943 RAP Booklet Low Staple.024-945 RAP Booklet Full
    Stack.024-946 RAP Tray 1 Not In Position.024-947 RAP Tray 2 Not In
    Position.024-948 RAP Tray 3 Not In Position.024-949 RAP Tray 4 Not
    In Position.024-950 RAP Tray 1 No Paper.024-951 RAP Tray 2 No
    Paper.024-952 RAP Tray 3 No Paper.024-953 RAP Tray 4 No
    Paper.024-954 RAP MSI No Paper.024-955 RAP Tray 6 No Paper.024-956
    RAP Tray 7 No Paper.024-957 RAP Interposer No Paper.024-958 RAP MSI
    Size Mismatch.024-959 RAP Tray 1 Paper Size Mismatch.024-960 RAP
    Tray 2 Paper Size Mismatch.024-961 RAP Tray 3 Paper Size
    Mismatch.024-962 RAP Tray 4 Paper Size Mismatch.024-965 RAP ATS/APS
    No Paper.024-966 RAP ATS/APS No Destination Error.024-967 RAP
    Different Width Mix Paper Detect (Staple Job).024-968 RAP
    Stapler/Punch Batting.024-969 RAP Different Width Mix Punch.024-970
    RAP Tray 6 Not In Position.024-971 RAP Tray 7 Not In
    Position.024-972 RAP Tray 6 Paper Size Mismatch.024-973 RAP Tray 7
    Paper Size Mismatch.024-974 RAP Interposer Tray Size
    Mismatch.024-975 RAP Booklet Sheets Over Count (Not Field
    Attachment).024-976 RAP Finisher Staple Status incorrect.024-977
    RAP Stapler Feed Ready Failure.024-978 RAP Booklet Stapler
    incorrect.024-979 RAP Stapler Near Empty.024-980 RAP Finisher
    Stacker Tray Full.024-981 RAP Finisher Top Tray Full.024-982 RAP
    Stacker Lower Safety Warning.024-983 RAP Booklet Tray Full.024-984
    RAP Booklet Low Staple F.

  • 024-985 RAP SMH Stop Check.024-987 RAP Envelope Folder Tray
    Full.024-988 RAP Envelope Folder Tray Set Failure.024-989 RAP
    Booklet Low Staple R.024-990 RAP Punch Dust Full.025-596 RAP Diag
    HDD Failure 1.025-597 RAP Diag HDD Failure 2.027-452 RAP Duplicate
    IP address.027-500 RAP SMTP Server Address Resolution
    Failure.027-501 RAP POP Server Address Resolution Failure.027-502
    RAP POP Authentication Failure.027-700 RAP Media Failure.027-701
    RAP Media Not Found.027-702 RAP Media Data Not Found / Not
    Supported.027-703 RAP Media Reader Failure / Disconnected.027-706
    RAP Certificate not found.027-707 RAP Certificate expired.027-708
    RAP Certificate untrusted.027-709 RAP Certificate revoked.027-710
    RAP S/MIME mail was disabled.027-711 RAP S/MIME mail sender
    certificate not found.027-712 RAP S/MIME mail sender certificate
    not valid.027-713 RAP S/MIME mail was altered.027-714 RAP S/MIME
    mail sender impersonation.027-715 RAP S/MIME mail certificate not
    supported.027-716 RAP No-Signed mail receipt was rejected.027-720
    RAP Ext Srv. Host Not Found. A server specified for a remote
    application was not found, or DNS resolution was not
    possible.027-721 RAP Ext Srv. Not Found.027-722 RAP Ext Srv.
    Timeout Failure.027-723 RAP Ext Srv. Authentication Failure.027-724
    RAP Ext Srv. Access Failure.027-725 RAP Ext Srv. Operation
    Failure.027-726 RAP Ext Srv. Unknown State.027-727 RAP Ext Srv. Req
    Invalid Parameters.027-728 RAP Ext Srv. Required File
    Exceeded.027-737 RAP Template Server Read Error.027-739 RAP Invalid
    Template Server Path.027-740 RAP Template Server Login
    Error.027-741 RAP Template Server Connect Failure.027-742 RAP HD
    File System Full.027-743 RAP Template Server Install Error.027-744
    RAP Template Server ADD Error.027-745 RAP Template Server ADD
    Error.027-746 RAP Job Template Pool Server Not Ready.027-751 RAP
    Job Template Analysis Error.027-752 RAP Must User un
    Inputting.027-753 RAP Job Flow Service Request Disabled.027-760 RAP
    XJT Command Failure.027-770 RAP PDL Error.027-771 RAP DFE Disk
    Full.027-796 RAP Email Not Printed.

  • 027-797 RAP Invalid Output Destination.042-313 RAP Rear Cooling
    Fan Failure.042-320 RAP Yellow Drum Motor Drive Failure.042-321 RAP
    Magenta Drum Motor Drive Failure.042-322 RAP Cyan Drum Motor Drive
    Failure.042-323 RAP Black Drum Motor Drive Failure.042-324 RAP IBT
    Drive Motor Failure.042-325 RAP Main Motor Failure.042-326 RAP Belt
    Home Position too long.042-327 RAP Belt Position Failure.042-328
    RAP Belt Edge Sensor Failure.042-330 RAP Fuser Exhaust Fan
    Failure.042-331 RAP Blower Motor Fan Failure.042-600 RAP Belt Walk
    Failure.042-601 RAP Belt Edge Learn Failure.042-602 RAP Belt Edge
    Check Failure.042-603 RAP Suction Filter Life End Failure.045-310
    RAP Image Ready NG.045-311 RAP Controller Comm Failure.045-312 RAP
    Driver Connect Failure.047-210 RAP OCT Offset Failure.047-310 RAP
    MCU-Finisher Communication Failure.061-310 RAP Clapper 1
    Failure.061-311 RAP Clapper 2 Failure.061-313 RAP SOS Long Failure
    Magenta.061-315 RAP SOS Long Failure Black.061-317 RAP SOS Short
    Failure.061-319 RAP SOS Short Failure Black.061-320 RAP Polygon
    Motor Failure.061-321 RAP ROS Motor Failure.061-323 RAP No SOS
    Failure.061-324 RAP No SOS Failure.061-325 RAP No SOS
    Failure.061-326 RAP ROS Connect Failure Yellow.061-327 RAP ROS
    Connect Failure.061-328 RAP ROS Connect Failure.061-329 RAP ROS
    Connect Failure Black.061-334 RAP ROS Y/M VDD Failure.061-335 RAP
    ROS C/K VDD Failure.061-336 RAP ROS Y/M VDD Down Failure.061-337
    RAP ROS C/K VDD Down Failure.061-338 RAP SOS Stop Magenta
    Failure.061-339 RAP SOS Stop Black Failure.061-340 RAP ROS LD
    Failure Black.061-341 RAP ROS LD Failure Yellow.061-342 RAP ROS LD
    Failure Magenta.061-343 RAP ROS LD Failure Cyan.061-600 RAP ROS
    Data Failure Yellow.061-601 RAP ROS Data Failure Magenta.061-602
    RAP ROS Data Failure Cyan.061-603 RAP ROS Data Failure
    Black.061-604 RAP LD Alarm Yellow.

  • 061-605 RAP LD Alarm Magenta.061-606 RAP LD Alarm Cyan.061-607
    RAP LD Alarm Black.062-210 RAP IISS Hot Line Failure.062-211 RAP
    IIT/IPS EEPROM Failure (IPS).062-220 RAP IPS-EXT Connection
    Failure.062-277 RAP IIT/IPS-DADF Communication Failure.062-278 RAP
    IIT-Extension Communication Failure.062-300 RAP Platen Interlock
    Open.062-310 RAP IIT/IPS-ESS Communication Failure.062-311 RAP IIT
    Software Logic Failure.062-321 RAP IPS-YATA Connection
    Failure.062-322 RAP EXT-YATA Connection Failure.062-323 RAP YATA
    PWBA Failure.062-345 RAP IIT/IPS EEPROM Failure (IIT).062-355 RAP
    IPS Fan Failure.062-356 RAP Lamp Fan Failure.062-357 RAP CCD Fan
    Failure. An error signal was detected for the CCD fan.062-360 RAP
    Carriage Position Failure.062-362 RAP X Hard Failure.062-371 RAP
    Lamp Failure.062-380 RAP Platen AOC Failure.062-386 RAP Platen AOC
    Failure.062-389 RAP Carriage Over Run (Scan End).062-392 RAP IT/IPS
    Memory Failure.062-393 RAP IIT/IPS PWB Failure.062-790 RAP X Detect
    Failure.063-210 RAP Extension EEPROM Failure.063-220 RAP IPS-EXT
    Psync Failure.063-230 RAP EXT Image Parameter Failure.063-240 RAP
    EXT Image Parameter Failure.065-210 RAP Extension Page Memory
    Failure 1.065-211 RAP CIS Shading FROM Failure065-212 RAP CIS
    Shading Level Failure.065-213 RAP CIS Output Level Failure.065-215
    RAP Extension Page Memory Failure 2.065-216 RAP Extension Page
    Memory Failure 3.065-219 RAP CIS Black White Level Failure.065-220
    RAP 1P DUP PWB-EXT Psync Failure.071-101 RAP Feed Out Sensor 1 is
    not turned ON.071-104 RAP Pre Registration Sensor ON Jam (Tray
    1).071-105 RAP Registration Sensor ON Jam (Tray 1).071-210 RAP Tray
    1 Lift Up Failure.072-101 RAP Tray 2 Miss Feed Jam.072-102 RAP The
    Tray 1 Feed Out Sensor does not turn ON.072-104 RAP
    Pre-Registration Sensor ON Jam (Tray 2).072-105 RAP Registration
    Sensor ON Jam (Tray 2).072-210 RAP Tray 2 Lift Up Failure.073-101
    RAP Tray 3 Miss Feed Jam.073-102 RAP Feed Out Sensor 1 ON Jam (Tray
    3).073-104 RAP Pre Registration Sensor ON Jam (Tray 3).073-105 RAP
    Registration Sensor ON Jam (Tray 3).

  • 073-210 RAP Tray 3 Lift Up Failure.074-101 RAP Pre Feed Sensor 4
    is not ON within the specified time after the start of feed from
    Tray 4.074-102 RAP Feed Out Sensor 1 ON Jam (Tray 4).074-103 RAP
    The Tray 4 Feed Out Sensor is not ON within the specified time for
    paper fed from Tray 4.074-104 RAP Pre Registration Sensor ON Jam
    (Tray 4).074-105 RAP Registration Sensor ON Jam (Tray 4).074-210
    RAP Tray 4 Lift Up Failure.075-100 RAP Tray 5/Bypass Pre Feed
    Sensor is not ON within the specified time after the start of feed
    from Tray 5.075-101 RAP Tray 5/Bypass Feed Out Sensor is not ON
    within the specified time for paper fed from Tray 5.075-109 RAP
    Paper from Tray 5/Bypass does not turn ON Pre Regi Sensor within a
    specified time.075-135 RAP Paper from Tray 5/Bypass does not turn
    ON Regi Sensor within a specified time.075-210 RAP Tray 5/Bypass
    Lift Up Sensor does not turn ON within a specified time after Tray
    5 begins to lift.075-211 RAP Tray 5/Bypass Lift Down Sensor does
    not turn ON within a specified time after Tray 5 begins to
    lower.077-102 RAP Paper from Tray 2 did not turn on the Transport
    Path Sensor 1 within the specified time.077-103 RAP The Fuser Exit
    Sensor did not turn off within the specified time in straight exit
    mode.077-106 RAP The Fuser Exit Sensor did not come on within the
    specified time after the Registration Motor.077-107 RAP The Fuser
    Exit Sensor did not turn off within the specified time in invert
    exit mode.077-109 RAP The IOT Exit Sensor did not come on at the
    specified time in non-invert mode.077-111 RAP The IOT Exit Sensor
    did not come on within the specified time in invert exit
    mode.077-113 RAP The IOT Exit Sensor did not turn off at the
    specified time in non-invert mode.077-115 RAP The IOT Exit Sensor
    did not turn off within the specified time in invert exit
    mode.077-118 RAP Paper from Duplex did not turn on the Pre Regi
    Sensor within the specified time.077-120 RAP Post 2nd BTR Sensor On
    JAM.077-123 RAP Duplex In Sensor does not turn ON a spec time after
    the start of invert.077-129 RAP Paper from Duplex did not turn on
    the Regi Sensor within the specified time.077-130 RAP Duplex Out
    Sensor does not turn ON witin a specified time after Duplex In
    Sensor turns ON.077-300 RAP The Front Cover is open.077-301 RAP The
    Left Hand Interlock is open.077-302 RAP The Right Hand Cover
    Interlock is open.077-303 RAP PH Drawer Interlock Open.077-304 RAP
    The Tray 5/Bypass Cover Interlock is open.077-312 RAP Feeder
    Communication Failure.077-909 RAP One of the IOT sensors detected
    paper when power was turned on or when an interlock was
    closed.077-967 RAP The specified paper type and the paper type
    being used are different.077-968 RAP The type of paper in the tray
    was changed.078-100 RAP Paper from Tray 6 does not turn ON Pre Regi
    Sensor within a specified time.078-101 RAP The Tray 6 Feed Out
    sensor is not ON within the specified time for paper fed from Tray
    6.078-102 RAP Paper from Tray 6 does not turn ON the Regi Sensor
    within a specified time.078-151 RAP The Tray 6 Feed Out Sensor did
    not come on within the specified time after the start of
    feed.078-250 RAP HCF Tray #2 Lift Up Fail.

  • 078-300 RAP The HCF transport interlock is open.078-301 RAP HCF
    Side Out Interlock Open.089-600 RAP Incorrect Fast Scan positioning
    for the reference color Cyan was detected during fine
    adjustment.089-601 RAP The Inner MOB Sensor failed to detect the
    fine-adjustment patterns properly during fine adjustment.089-602
    RAP The CENTER MOB Sensor failed to detect the fine-adjustment
    patterns properly during fine adjustment.089-603 RAP The OUTER MOB
    Sensor failed to detect the fine-adjustment patterns properly
    during fine adjustment.089-604 RAP The INNER MOB Sensor failed to
    detect the rough-adjustment patterns properly during Yellow rough
    adjustment.089-605 RAP The CENTER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Yellow rough
    adjustment.089-606 RAP The OUTER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Yellow rough
    adjustment.089-607 RAP The INNER MOB Sensor failed to detect the
    rough-adjustment patterns correctly during Magenta rough
    adjustment.089-608 RAP The CENTER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Magenta rough
    adjustment.089-609 RAP The OUTER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Magenta rough
    adjustment.089-610 RAP The INNER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Cyan rough
    adjustment.089-611 RAP The CENTER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Cyan rough
    adjustment.089-612 RAP The MOB Sensor OUT failed to detect the
    rough-adjustment patterns properly during Cyan rough
    adjustment.089-613 RAP The INNER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Black rough
    adjustment.089-614 RAP The CENTER MOB Sensor failed to detect the
    rough-adjustment patterns properly during Black rough
    adjustment.089-615 RAP The MOB Sensor OUT failed to detect the
    rough-adjustment patterns properly during Black rough
    adjustment.089-616 RAP RC Data OverFlow Failure.089-617 RAP RC Data
    OverRange Failure.091-311 RAP The voltage level of the CC cleaner
    position sensor did not change within the specified time.091-312
    RAP Charge (K) Preclean HVPS has failed.091-313 RAP DRUM CRUM ASIC
    Communication Failure.091-320 RAP Charge Corotron Wire is
    broken.091-400 RAP The replacement date for Waste Toner Bottle
    (regular) is near.091-401 RAP The black drum cartridge is near the
    end-of-life.091-403 RAP The CC Assembly is near the
    end-of-life.091-404 RAP The CC Assembly has reached the
    end-of-life.091-411 RAP The yellow drum cartridge is near the
    end-of-life.091-421 RAP The magenta drum cartridge is near the
    end-of-life.091-431 RAP The cyan drum cartridge is near the
    end-of-life.091-910 RAP The waste toner bottle is not
    present.091-911 RAP The waste toner bottle is full.091-913 RAP The
    black drum cartridge (K) has reached the end-of-life.091-914 RAP
    Communication failure between the MCU and the black Drum CRUM.

  • 091-915 RAP The MCU detected incorrect data in the black drum
    cartridge CRUM.091-916 RAP The CRUM authentication registration
    data on the drum cartridge is incorrect.091-917 RAP MCU cannot
    communicate with the CRUM in drum Y.091-918 RAP Communication
    failure with the magenta Drum CRUM.091-919 RAP Communication
    failure with the cyan Drum CRUM.091-920 RAP The MCU detected
    incorrect data in the Yellow drum cartridge CRUM.091-921 RAP Drum
    CRUM is disconnected.091-922 RAP Wrong Data in magenta drum
    cartridge.091-923 RAP Wrong data in cyan drum cartridge.091-924 RAP
    The CRUM authentication registration data on the yellow drum
    cartridge is incorrect.091-925 RAP Wrong data in yellow Magenta
    cartridge.091-926 RAP The CRUM authentication registration data on
    the cyan drum cartridge is incorrect.091-927 RAP Yellow Drum CRUM
    is disconnected.091-928 RAP Magenta Drum CRUM is
    disconnected.091-929 RAP Cyan Drum CRUM is disconnected.091-932 RAP
    The yellow drum cartridge (Y) has reached the end-of-life.091-933
    RAP The magenta drum cartridge (M) has reached the
    end-of-life.091-934 RAP The cyan drum cartridge (C) has reached the
    end-of-life.092-649 RAP The MOB ADC Shutter remains open due to
    shutter failure.092-650 RAP The MOB ADC Shutter remains closed due
    to shutter failure.092-651 RAP The output read by ADC Sensor from
    the clean Photoreceptor surface is out of range.092-652 RAP The
    measured ADC Patch density is light. (Over 75% of Vclean).092-653
    RAP ATC SNR-Yellow output signal failure.092-654 RAP ATC
    SNR-Magenta output signal failure.092-655 RAP ATC SNR-Cyan output
    signal failure.092-656 RAP ATC SNR-black output signal
    failure.092-657 RAP The amplitude of ATC Yellow Sensor output is
    out of range.092-658 RAP The amplitude of ATC Magenta Sensor output
    is out of range.092-659 RAP The amplitude of ATC Cyan Sensor output
    is out of range.092-660 RAP The amplitude of ATC Black Sensor
    output is out of range.092-661 RAP The temperature output of the
    environment sensor is out of range.092-662 RAP The humidity output
    of the environment sensor is out of range.092-663 RAP The two
    levels of ADC Patch density created in Mini-Setup are
    reversed.093-300 RAP Marking Drawer Interlock Open.093-313 RAP The
    Low Toner Sensor failed to detect any toner after the Toner
    Cartridge Motor was energized.093-314 RAP Yellow Dispense
    failure.093-315 RAP Magenta Dispense failure.093-316 RAP Cyan
    Dispense failure.093-317 RAP Black Dispense failure.093-320 RAP
    There was a problem with the developer motor rotation.093-421 RAP
    The Black Toner Cartridge (K1) is empty and the Black Toner
    Cartridge (K2) is near empty.093-422 RAP The Black Toner Cartridge
    (K2) is empty and the Black Toner Cartridge (K1) is near
    empty.093-423 RAP Yellow toner is near empty.093-424 RAP Magenta
    toner is near empty.093-425 RAP Cyan toner empty.093-600 RAP Yellow
    Dispense near failure.093-601 RAP Magenta Dispense near
    failure.093-602 RAP Cyan Dispense near failure.093-603 RAP Black
    Dispense near failure.

  • 093-912 RAP The Black Dispense Motor rotation timed out
    indicating that the Black Cartridge and Reserve Tank are
    empty.093-918 RAP A communication failure with Black Toner
    Cartridge CRUM K2.093-924 RAP A communication failure with Black
    Toner Cartridge CRUM K1.093-925 RAP The data written to the toner
    CRUM K1 did not agree with the data read.093-926 RAP Toner
    Cartridge CRUM K1 Authentication Data is different.093-927 RAP A
    communication failure with Yellow Toner Cartridge CRUM Y.093-928
    RAP A communication failure with Magenta Toner Cartridge CRUM
    M.093-929 RAP A communication failure with Cyan Toner Cartridge
    CRUM C.093-932 RAP Cartridge Exchange Time Over.093-934 RAP The
    data written to the toner CRUM M did not agree with the data
    read.093-935 RAP The data written to the toner CRUM C did not agree
    with the data read.093-936 RAP The data written to the toner CRUM
    K2 did not agree with the data read.093-937 RAP Toner Cartridge
    CRUM Y Authentication Data is different.093-938 RAP Toner Cartridge
    CRUM M Authentication Data is different.093-939 RAP Toner Cartridge
    CRUM C Authentication Data is different.093-940 RAP Toner Cartridge
    CRUM K2 Authentication Data is different.094-320 RAP Retraction was
    not detected within the specified time after retraction of the 1st
    BTR started.094-321 RAP First BTR Contact Failure.094-322 RAP
    Second BTR Retract Failure.094-323 RAP Contact was not detected
    within the specified time after contact with the 2nd BTR
    started.102-356 RAP Fatal error related to the EWS.102-380 RAP
    Fatal error in the MF UI count.102-381 RAP ESS error during
    communication between ESS and the control panel.102-382 RAP A
    verification message was not returned from the Control Panel within
    the specified time.112-700 RAP The punch dust box is full.116-210
    RAP Media Reader Fatal Error.116-211 RAP Media Reader Cable
    disconnected.116-212 RAP [Media Reader] MediaLib SW Logic
    Failure.116-310 RAP An error was detected while checking ESS font
    ROM DIMM #1.116-312 RAP An error was detected in the HDD encryption
    key during activation.116-313 RAP An encryption key was specified
    but the HDD itself was not encrypted.116-314 RAP An ethernet error
    was detected.116-315 RAP An error was detected during System Memory
    1 R/W.116-316 RAP An error was detected during System Memory 2
    R/W.116-317 RAP An error was detected when checking the MF
    ROM.116-318 RAP An error was detected when checking the expansion
    ROM R2.116-321 RAP System Software Fatal Error.116-322 RAP WebDAV
    S/W Failure.116-323 RAP An error was detected during the ESS PWB
    NVM Read/Write Check.116-324 RAP A fatal software exception error
    has occurred in the Controller PWB CPU.116-325 RAP An error
    occurred in ESS fan rotation.116-329 RAP A system call error
    related to the serial I/F was detected.116-330 RAP Error during HDD
    check.116-331 RAP An error related to the log was detected.116-332
    RAP An error in the MF ROM ( ) was detected.116-333 RAP A problem
    occurred during software processing, and processing could no longer
    continue.116-336 RAP Redirector HD Failure. A problem was detected
    during HD access.

  • 116-337 RAP Fatal error with SNTP in general.116-338 RAP Fatal
    error with JBA in general.116-340 RAP There was insufficient page
    memory, input buffers, or work area.116-341 RAP Incorrect version
    or invalid combination ROM DIMMs are installed.116-342 RAP Fatal
    error related to the SNMP agent.116-343 RAP An IC error within the
    ESS PWB was detected.116-346 RAP Formatter failure. Error return
    from a system call.116-348 RAP Redirector failure. Error return
    from a system call.116-349 RAP There was an error with a call
    within SIF related to Pflite.116-350 RAP Fatal error with AppleTalk
    in general.116-351 RAP Fatal error related to EtherTalk.116-352 RAP
    Fatal error related to NetWare.116-353 RAP A physical problem was
    detected with the HDD during activation, causing the HDD not to
    activate.116-354 RAP A problem with the HDD product code was
    detected during activation.116-355 RAP Fatal error related to the
    SNMP agent.116-356 RAP The HDD was formatted, but an HDD failure
    occurred.116-357 RAP PostScript fatal system error.116-358 RAP
    Fatal error related to the salutation.116-359 RAP Fatal error in
    PLW.116-360 RAP Fatal error related to SMB.116-361 RAP SPL HDD
    fatal error. SpoolCont detected an error during HDD access.116-362
    RAP SSDP software failure.116-363 RAP BMLinkS or print service
    software failure.116-364 RAP A timer error was detected.116-365 RAP
    SPL fatal error.116-366 RAP Report generator incorrect
    operation.116-367 RAP Parallel fatal error.116-368 RAP DumpPrint
    fatal error.116-370 RAP XJCL fatal error.116-371 RAP PCL Decomposer
    Software Failure. PCL fatal error.116-373 RAP Fatal error related
    to Dynamic DNS.116-374 RAP AutoSW fatal error.116-376 RAP Port 9100
    Software Fail.116-378 RAP Fatal error related to MCR.116-379 RAP
    Fatal error related to MCC.116-380 RAP An error was detected while
    checking ESS font ROM DIMM #1.116-381 RAP The ABL did not agree
    with the ABL version information in NVM, or the data was
    corrupted.116-382 RAP An ABL access to NVM or HDD failed.116-385
    RAP Fatal error related to the IDC.116-388 RAP It was detected that
    no HD is installed.116-389 RAP The system detected that no
    additional RAM was installed.116-390 RAP A version mismatch was
    detected between the standard ROM and NVM.116-391 RAP Incorrect
    specification of the country code, territory code, or paper size
    group.116-395 RAP Fatal error related to the USB.116-701 RAP Duplex
    printing is not possible due to insufficient memory.116-702 RAP
    Printing occurred with a substitute font.116-703 RAP PostScript
    data problem during PostScript grammar interpretation or language
    interpretation.116-704 RAP MediaReader No Insert (No Job).116-705
    RAP MediaReader Format Error (No Job).

  • 116-706 RAP MediaReader: File Attribute Read Error (No
    Job).116-707 RAP MediaReader: Image File Read Error (No
    Job).116-708 RAP MediaReader: File Attribute Read Error (In
    Job).116-709 RAP MediaReader: Image File Read Error (Occurs during
    job).116-710 RAP Original size not correctly determined.116-711 RAP
    Mismatch in size and direction or ART EX form with paper to be
    printed.116-712 RAP PLW form / logo data cannot be registered due
    to insufficient RAM or HD space.116-713 RAP The job was divided
    because the HDD was full.116-714 RAP An HP-GL/2 (option) command
    error occurred.116-715 RAP The form could not be registered because
    the ART EX form registration upper limit was reached.116-716 RAP
    MediaReader File Does Not Exist.116-717 RAP MediaLib: Not Execute
    of New Request.116-718 RAP The specified ART EX form has not been
    registered.116-720 RAP PCL Memory Low, Page Simplified.116-737 RAP
    User defined data could not be registered because there was
    insufficient ART IV user definition memory.116-738 RAP Synthesis
    problem due to the specified ART IV form size and direction were
    different from the paper size and direction.116-739 RAP Form / logo
    data could not be registered because there was insufficient ART IV
    memory or HDD capacity.116-740 RAP An error occurred because the
    print data exceeded the printer limit.116-741 RAP No more forms can
    be registered because the number of ART IV Forms registered has
    reached the upper limit.116-742 RAP No more logo data can be
    registered because the number of ART IV log data registered has
    reached the upper limit.116-743 RAP The form or logo data could not
    be registered due to insufficient ART IV memory.116-745 RAP An ART
    IV command error occurred.116-746 RAP The specified form has not
    been registered.116-747 RAP The paper margin value is too large for
    the HP-GL/2 (option) effective coordinate area.116-748 RAP The
    HP-GL/2 (option) print data does not contain any image data.116-749
    RAP The specified PostScript font is not in ROM or HDD.116-771 RAP
    Invalid JBIG Parameter DL Fixed.116-772 RAP Invalid JBIG Parameter
    D Fixed.116-773 RAP Invalid JBIG Parameter P Fixed.116-774 RAP
    Invalid JBIG Parameter YD Fixed.116-775 RAP Invalid JBIG Parameter
    LO Fixed.116-776 RAP Invalid JBIG Parameter MX Fixed.116-777 RAP
    Invalid JBIG Parameter MY Fixed.116-778 RAP Invalid JBIG Parameter
    VLENGTH Fixed.116-780 RAP There was a problem with the document
    attached to the received mail.116-790 RAP Stapling was
    cancelled.123-200 RAP The data received from ESS exceeded the
    buffer size of the storage destination within the control
    panel.123-201 RAP Data intended to be received from the control
    panel exceeded the buffer size of the storage destination within
    the control panel.123-202 RAP Events occurred that exceeded the
    processing capability for requests generated within the control
    panel.123-203 RAP UI Debug code.123-204 RAP SIO Parameter Failure
    (UI-Control panel).123-205 RAP SIO Command Failure (UI-Control
    panel).

  • 123-206 RAP SIO Status Failure (UI-Control panel).123-207 RAP
    Comm Manager Target Failure (UI-Control panel).123-208 RAP Comm
    Manager Command Failure (UI-Control panel).123-209 RAP EVM Returns
    Wrong Value (UI-Control panel).123-310 RAP Send Queue Full
    (UI-Control panel).123-311 RAP Receive Queue Full (UI-Control
    panel).123-312 RAP EVM Uses Wrong API (UI-Control panel).123-313
    RAP AS Uses Wrong API (UI-Control panel).123-314 RAP Event-Waiting
    Timer Timeout (UI-Control panel).123-315 RAP CTS Internal Failure
    (UI-Control panel).123-316 RAP Send Request Queue Full SIO
    (UI-Control panel).123-317 RAP Receive Message Queue Full
    (UI-Control panel).123-318 RAP Receive Finish Queue Full
    (UI-Control panel).123-319 RAP Send Failure with No ACK (UI-Control
    panel).123-320 RAP Polling Failure (UI-Control panel).123-321 RAP
    Send Message Failure (UI-Control panel).123-322 RAP Target Failure
    (UI-Control panel).123-323 RAP Address Failure (UI-Control panel).
    Serial communication error.123-324 RAP Size Failure (UI-Control
    panel). Serial communication error.123-325 RAP Object Creation
    Failure (UI-Control panel).123-326 RAP Memory Overflow (UI-Control
    panel).123-327 RAP Button Overflow (UI-Control panel).123-328 RAP
    UI Internal Failure with Out of Area.123-329 RAP UI Internal
    Failure with Invalid Coordinates.123-330 RAP Interface Failure with
    Invalid Parameter LCD.123-331 RAP UI Internal Failure with Invalid
    LED Request.123-332 RAP I/F Failure (Invalid Parameter CP).123-333
    RAP I/F Failure (No Communication).123-334 RAP I/F Failure
    (Receiving Error Key Code).123-335 RAP I/F Failure (Receiving
    Invalid Coordinates).123-336 RAP I/F Failure (DM-ACD Drv.
    I/F).123-337 RAP Frame Data Error with Invalid Data Type.123-338
    RAP Frame Data Error Offset Address Out.123-339 RAP Display Request
    Code Invalid.123-340 RAP Interface Failure GUAM-DM I/F.123-341 RAP
    Event Queue Full (UI-Control panel).123-342 RAP Event Queue Empty
    (UI-Control panel).123-343 RAP Invalid Class (UI-Control
    panel).123-344 RAP Invalid Type (UI-Control panel).123-345 RAP
    Timer Queue Full (UI-Control panel).123-346 RAP Invalid Timer
    Number (UI-Control panel).123-347 RAP Undefined Trap (UI-Control
    panel).123-348 RAP Command Access Exception (UI-Control
    panel).123-349 RAP Invalid Command (UI-Control panel).123-350 RAP
    Privilege Command (UI-Control panel).123-351 RAP No FPU Exception
    (UI-Control panel).123-352 RAP Address Mis-align (UI-Control
    panel).123-353 RAP Data Access Exception (UI-Control panel).123-354
    RAP Tag Overflow (UI-Control panel).123-355 RAP No Co Processor
    Exception (UI-Control panel).123-356 RAP Short of Area (UI-Control
    panel).123-357 RAP Cancel Wait Status (UI-Control panel).

  • 123-358 RAP Timeout (UI-Control panel).123-359 RAP Queue
    Overflow (UI-Control panel).123-360 RAP Context Failure (UI-Control
    panel).123-361 RAP Object Failure (UI-Control panel).123-362 RAP No
    Object (UI-Control panel).123-363 RAP Invalid ID (UI-Control
    panel).123-364 RAP Parameter Failure (UI-Control panel).123-365 RAP
    Reserve Attribute (UI-Control panel).123-366 RAP Reserve Function
    Code (UI-Control panel).123-367 RAP Unsupported Function
    (UI-Control panel).123-368 RAP Short of UI Memory (UI-Control
    panel).123-369 RAP Invalid Interface Value (UI-Control
    panel).123-370 RAP Interface Length Failure (UI-Control
    panel).123-371 RAP Interface Parameter Failure (UI-Control
    panel).123-372 RAP Interface Sequence Failure (UI-Control
    panel).123-373 RAP Channel Failure (UI-Control panel).123-374 RAP
    Invalid User Job ID (UI-Control panel).123-375 RAP Internal
    Resource Failure (UI-Control panel).123-376 RAP Internal Memory
    Failure (UI-Control panel).123-377 RAP UI Timer Failure (UI-Control
    panel).123-378 RAP Interface Format Failure (UI-Control
    panel).123-379 RAP Dispatch Failure (UI-Control panel).123-380 RAP
    Copy Interface Failure (UI-Control panel).123-382 RAP Scanner
    Interface Failure (UI-Control panel).123-383 RAP Report Interface
    Failure (UI-Control panel).123-384 RAP Server Access Failure
    (UI-Control panel).123-385 RAP Service Object Overflow (UI-Control
    panel).123-386 RAP Invalid Service Object (UI-Control
    panel).123-387 RAP Invalid Service Object Attribute (UI-Control
    panel).123-388 RAP Attribute Failure (UI-Control panel).123-389 RAP
    Argument Failure (UI-Control panel).123-390 RAP Job Parameter
    Failure (UI-Control panel).123-391 RAP Job Actual Parameter Failure
    (UI-Control panel).123-392 RAP Auditron Failure (UI-Control
    panel).123-393 RAP EP Failure (UI-Control panel).123-394 RAP File
    Access Failure (UI-Control panel).123-395 RAP NVM Failure
    (UI-Control panel).123-396 RAP FF Failure (UI-Control
    panel).123-397 RAP MGR Failure (UI-Control panel).123-398 RAP Delay
    Release Queue Full (UI-Control panel).123-399 RAP Internal Failure
    (UI-Control panel).123-400 RAP Internal Failure (UI-Control
    panel).124-310 RAP DC132 11 — The product number was not
    specified.124-311 RAP DC132 09 — The serial number registration
    field failed.124-312 RAP DC132 12 — Product numbers did not
    agree.124-313 RAP DC132 10 — Serial numbers did not agree.124-314
    RAP DC 132-01 — IOT Speed Failure.124-315 RAP DC 132-02 — IOT Speed
    Mismatch.124-316 RAP DC 132-04 — Product a/f Model Failure.124-317
    RAP DC 132-04 — Product a/f All Product Model Mismatch.124-318 RAP
    Product Type for S/W Key Failure.124-319 RAP DC 132-08 — All
    Product Type For S/W Key Mismatch.

  • 124-320 RAP EEP ROM Failure.124-321 RAP Backup SRAM Failure. An
    NVM ROM write problem occurred on the ESS PWB.124-322 RAP DC 132-05
    — Copy/Scan/Print S/W Key by PWE Failure.124-323 RAP DC 132-06 —
    Copy/Scan/Print S/W Key 1 Failure.124-324 RAP All Billings
    Mismatch.124-325 RAP Billing Restoration Failure.124-333 RAP ASIC
    Failure (Panther).124-334 RAP Standard Font ROM Error.124-335 RAP
    Font ROM Not Found.124-337 RAP ESS Standard RAM Error.124-338 RAP
    Same Font ROMs Found.124-339 RAP ROM DIMM of another product
    found.124-340 RAP The three CRUM market destination values are not
    set up (0 or different).124-341 RAP One CRUM market destination
    value is different (IOT).124-342 RAP One CRUM market destination
    value is different (SYS 1).124-343 RAP One CRUM market destination
    value is different (SYS 2).124-350 RAP The three CRUM OEM
    destination values are not set up (0 or different).124-351 RAP One
    CRUM OEM destination value is different (IOT).124-352 RAP One CRUM
    OEM destination value is different (SYS 1).124-353 RAP One CRUM OEM
    destination value is different (SYS 2).124-360 RAP CRUM
    Valid/Invalid is not set up at the three locations (0 or different
    values).124-361 RAP CRUM Validation Failure MCU.124-362 RAP CRUM
    Validation Failure SYS 1.124-363 RAP CRUM Validation Failure SYS
    2.124-372 RAP IOT sc Soft Failure.124-373 RAP IOT Manager SW
    Failure.124-374 RAP IOT IM Device Driver SW Failure.124-380 RAP
    CRUM Market fail ALL (2).124-381 RAP CRUM Market fail MCU
    (2).124-382 RAP CRUM Market fail SYS 1 (2).124-383 RAP CRUM Market
    fail SYS 2 (2).124-390 RAP CRUM OEM fail ALL (2).124-391 RAP CRUM
    OEM fail MCU (2).124-392 RAP CRUM OEM fail SYS 1 (2).124-393 RAP
    CRUM OEM fail SYS 2 (2).124-701 RAP Side Tray to Center
    Tray.124-704 RAP The output tray was changed from the Folder Tray
    to the Center Tray and printing continued.124-705 RAP Punching
    Cancelled.124-706 RAP Folding Cancelled.124-708 RAP The output tray
    has been changed to the Sub Tray because a failure was detected in
    the specified output tray.124-709 RAP Stapler Sheet Count is too
    high.125-311 RAP PSWcont Unexpected Failure.127-210 RAP DFE
    Communication Failure.127-211 RAP DFE Parameter Error.127-212 RAP
    ExtPrint Check Mode Error.127-213 RAP External Print IF
    Mismatch.127-220 RAP Communication Error (video) detected by the
    DFE.127-221 RAP Communication Error (Command) detected by the
    DFE.127-310 RAP ESR Task Fatal Error.127-311 RAP ExtPRT.

  • 127-320 RAP DFE Critical Failure.127-337 RAP Job Template HDD
    Write Error.127-342 RAP Job Template Monitor Failure.127-353 RAP
    LPD Soft Fatal Error.127-354 RAP FTP Server Software
    Failure.127-396 RAP Mail I/O Soft Fatal error.127-398 RAP IPP Soft
    Fatal Error.127-399 RAP JME Soft Fatal Error.202-399 RAP Timer
    Internal Fail.

Log in or Sign up

061-341, 061-342, 061-343 error docucolor 240

Discussion in ‘Xerox Color Laser Printers & Color Copiers’ started by vlaros, Dec 10, 2015.


  1. vlaros

    vlaros
    Member

    Joined:
    Oct 2011
    Messages:
    10
    Location:
    Craiova

    Hi,

    Today my DC240 started showing alternatively the following errora:
    061-341
    061-342
    061-343
    Any ideas on how to fix it?

    Thnks


    vlaros,
    Dec 10, 2015

    #1


  2. victor076

    victor076
    Member

    Joined:
    Dec 2010
    Messages:
    14
    Location:
    Mexico

    yellow, magenta and cyan ROS LD Failure.
    According to the manual, this are the solutions.

    1.-Check the connection of each connector of the ROS Assembly.
    2.-Replace the ROS Assembly
    3.-Replace the MCU PWB


    victor076,
    Dec 16, 2015

    #2

(You must log in or sign up to reply here.)

Show Ignored Content

Loading…

Similar Threads


  1. Mister225

    Xerox 700 061-341 Error

    Mister225,
    Dec 29, 2021
    , in forum: Xerox Color Laser Printers & Color Copiers

    Replies:
    0
    Views:
    1,131
    Mister225
    Dec 29, 2021
Your name or email address:
Do you already have an account?
  • No, create an account now.
  • Yes, my password is:
  • Forgot your password?

Stay logged in


Color Printing Forum

Search

More…

Fault Code:

Description / Notes:

002-770

The Hard Drive (HDD)
is over capacity

003-xxx codes

Generally:
Communication Errors between boards in the machine

005-xxx codes

Generally: Document
Feeder problems

005-121 thru 005-158

Document Jams

005-194 thru 005-199

Document size mismatch
problems

005-275/280

Document Feeder
communication errors

005-281 thru 005-283

Document Tray lift
problems

005-284

Document APS (Automatic
Paper Sensors) failure (there are 3 sensors which detect various paper widths
on the Document Feeder)

005-285

Document Nudger up
failure

005-286

Document feed-out
sensor failure

005-303

Document Tray
Interlock is open

005-304

Document Platen
Interlock opened during a job

005-305

Document Top Cover
Interlock opened during a job

005-306

Document Tray
Interlock opened during a job

005-308/309

Document Left Cover is
open or opened during a job

005-906 thru 005-918

Document is still
detected in feeder after power-on or after closing one of the document door
interlocks

010-xxx codes

Generally: Fuser
faults

010-311

Open Fuser Thermistor
was detected (white connector)

010-319 *

Fuser Heat Control
problem *NOTE: This code must be cleared from Diagnostic Mode… details below.

010-320 **

Fuser Overheat
problem… (can be reported by any of the 3 thermistors in the fuser) ** NOTE:
This code must be cleared from Diagnostic Mode… details below.

010-322 thru 010-323

Fuser Thermistor open
circuit detected (NCCenter Sensor or Rear Thermistor)

010-324***

Fuser NVM (Memory)
failure *** NOTE: This code must be cleared from Diagnostic Mode… details below.

010-326 thru 010-327

Fuser Heat Control
problems

010-330

Fuser Motor failure

010-420

Fuser Module nearing
end of life… NOTE: Read below for fuser count reset info.

010-421

Fuser Module «End
of Life»… NOTE: If the fuser is still good, you can replace the Fuser
Reset Fuse (on top of the fuser) and possibly the Fuser Heat Roll to keep it
running.

012-xxx codes

Generally: Finisher
problems

013-xxx codes

Generally: Finisher /
Booklet Maker problems

016-xxx codes

Generally: Options or
Software failures

016-311

Scanner not detected

024-340 thru 024-747

ESS (Network
Controller) problems

024-910 thru 024-917

Paper size Sensing
problems (in one of the paper drawers)

024-919

Face Up Tray interlock
open

024-920/922

Face Down Tray 1 full
/ Face Down Tray 2 full

024-923/924/ 925

Toner Cartridge Empty
— Y / M / C

024-927/930

OCT (Offset Catch
Tray) full / Stacker Tray full

024-934 thru 024-939

Paper type mismatch
errors

024-946/947/ 948/949

Tray not in position
(T1/2/3/4)

024-950/951/
952/953/954/ 955/956

No Paper in tray
(T1/2/3/4/5/6/7)

042-313

Rear Fuser Cooling Fan
failure

042-320/321/ 322/323

Drum Motor failures —
320=Y, 321=C, 322=M, 323=K (black)

042-324

IBT Belt Drive Motor
failure

042-325

Main Motor failure

042-326

IBT Belt Home position
not detected in time

042-327

IBT Belt Position
failure

042-328

IBT Belt Edge Sensor
failure

042-330

Fuser Exhaust Fan
failure

042-331

Blower Motor Fan
failure

042-600/601/ 602

Belt Edge timing
failures

042-603

Suction Filter end of
life

045-xxx codes

Printing communication
failures

061-320/321

ROS (Laser Unit)
polygon motor failures

061-323 thru 061-607

ROS (Laser Unit)
problems

062-357

CCD (Scanner) Fan
failure

062-360

Exposure Carriage
position failure.

062-371

Exposure Lamp not
lighting (or very dim)

071-101 thru 071-105

Paper Jams from Tray 1
at takeaway or registration

071-210

Tray 1 Lift failure

072-101 thru 072-105

Paper jams from Tray 2
at takeaway or registration

072-210

Tray 2 Lift failure

073-101 thru 073-105

Paper jam from Tray 3
at takeaway or registration

073-210

Tray 3 Lift failure

074-101 thru 074-105

Paper jam from Tray 4
at takeaway or registration

074-210

Tray 4 Lift failure

075-100 thru 075-135

Paper jam from Tray 5
at takeaway or registration

075-210/211

Tray 5 Lift failure /
Lift down failure

077-103 thru 077-118

Fuser Exit Sensor jam
or final Exit Sensor jam.

077-120

Post 2nd BTR Roll
Sensor jam

077-123 thru 077-130

Inverter jams

077-300

Front Cover interlock
open

077-301

Left Door interlock
open

077-302

Right Cover interlock
open

077-303

Transfer Module 2
interlock open

077-909

Paper detected in
paper path at power-on

078-100 thru 078-151

Paper jam from Tray 6
/ High Capacity Feeder (HCF) at takeaway or registration

078-250

Tray 6 (HCF) Lift
failure

078-300

HCF (Hi Capacity
Feeder) Top Cover interlock open

078-301

HCF Docking Interlock
open

089-600 thru 089-617

Image Registration
Control problems

091-311

BCR and Black Charge
Corotron Cleaner control problem

091-312

Black Charge /
Preclean HVPS (Hi Volt Power Supply) failure

091-313

Drum Cartridge CRUM
(chip) communication failure

091-320

Black Charge Corona
Wire is broken

091-400

Waste Toner Bottle
replacement needed soon

091-401

Black Drum Cartridge
near end of life

091-403

Black Charge Corotron
Assembly near end of life

091-404

Black Charge Corotron
Assembly has reached end of life

091-411

Yellow Drum Cartridge
near end of life

091-421

Magenta Drum Cartridge
near end of life

091-431

Cyan Drum Cartridge
near end of life

091-910

Waste Toner Bottle not
detected

091-911

Waste Toner Bottle
full

091-913

Black Drum Cartridge
at end of life

091-914 thru 091-916
or 091-921

Black Drum Cartridge
CRUM communication problems

091-917/920/924/925/927

Yellow Drum Cartridge
CRUM communication problems

091-918/922/ 928

Magenta Drum Cartridge
CRUM communication problems

091-919/923/ 926/929

Cyan Drum Cartridge
CRUM communication problems

091-932

Yellow Drum Cartridge
end of life

091-933

Magenta Drum Cartridge
end of life

091-934

Cyan Drum Cartridge
end of life

092-649/650

ADC Sensor Shutter
failures

092-651/652

IBT Belt ADC Sensor
(MOB ADC) failures

092-653 thru 092-660

ATC (from Developer
Unit) problems…653/657=yellow, 654/658=magenta, 655/659=cyan, 656/660=black

093-300

Marking Drawer
Interlock open

093-313 thru 093-317

Toner Dispense
problems… 314=Y, 315=M, 316=C, 317=K (black)

093-320

Developer Motor
failure

093-421 thru 093-425

Toner Cartridges low
421/422=K(black), 423=Y, 424=M, 425=C

093-600 thru 093-912

Toner Dispense
problems (600=Y, 601=M, 602=C, 603/912=K(Black),

093-918 thru

Toner CRUM failures
(918/924 /925/926/936/ 940=K(black),927/933/937 =Y, 928/934/938 = M ,
929/935/939=C

093-940

094-320/321

1st BTR (Transfer
Roll) retract or contact problems

094-322/323

2nd BTR (Transfer
Roll) retract or contact problems

102-xxx codes

Generally: Network
Controller (ESS) problems

112-700

Finisher Punch Dust
Box full (hole punch bin)

116-xxx codes

Generally: Network
Controller (ESS) problems

123-xxx codes

Generally: UI (control
panel) faults

124-xxx codes

Generally:
Configuration errors (e.g., serial number disagreement between various boards
or machine speed errors, etc)

127-xxx codes

Printing failures

Понравилась статья? Поделить с друзьями:
  • Xerox dc 250 ошибка 061 327
  • Xerox dc 250 коды ошибок
  • Xerox dc 242 коды ошибок
  • Xerox dc 2020 ошибка 010 397
  • Xerox copycentre c118 ошибка c1 3000