Xerox 7132 ошибка 010 333

010-331, 010-333 Over Temperature Fail RAP

BSD-ON: BSD 10.2 Fusing Heat Control (1 of 2)

010-331 Fuser thermistor detected temperature monitor AD value that is the specified value or more 10 consecutive times.
010-333 Fuser NC sensor detected a temperature that is the specified value or more 10 consecutive times.

Initial Actions

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

• Remove the fuser. Check whether foreign substances or paper is wound around the heat roll.
• Ensure J416 on the drive PWB is securely connected.

Procedure

Perform the steps that follow:

1. Install new components as necessary:

• LVPS, PL 1.10 Item 3.
• Fuser, PL 10.05 Item 2.
• Drive PWB, PL 1.10 Item 4.
• ESS PWB, PL 3.10 Item 6.

2. To clear this fault, first remove the cause, then reset the value of NVM location 744-002 (Error Detection Flag) to 0. Switch off, then switch on the machine, GP 10.

NOTE: The relationship between the displayed value and the sensor that detected the high temperature error is as follows:

• 0: Normal.
• 1: High temperature error of heat roll nc sensor.
• 2: High temperature error of heat roll thermistor.
• 3: Abnormal temperature increase of heat roll NC sensor, heat roll thermistor.
• 4: Hardware high temperature error of heat roll thermistor.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Содержание

  1. 010 333 xerox error
  2. Fault Codes 058-310 to 058-313, 059-326, 010-333 to 010-335, and 010-338, 010-339: Fuser Thermal Error
  3. Materials required:
  4. Step 1: Power the Printer Off then On
  5. Step 2: Replace the Fuser and Reset the Counter
  6. How to Fix 010-331 010-333 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?
  7. 010 333 xerox error

КОНФЕРЕНЦИЯ СТАРТКОПИ
Принтеры, копировальные аппараты, МФУ, факсы и другая офисная техника:
вопросы ремонта, обслуживания, заправки, выбора

0. Alexeuss 24.08.17 04:08

Здравствуйте! У клиента уже давно стоит Xerox WC7132 с ошибкой 010-333, клиент новый по этому не знаю что делали предыдущие мастера с этим аппаратом. Что я сделал. по инструкции STRANNIK от 02.07.15 11:11
«Если на дисплее высветилась следующая ошибка 010-333, это говорит о недостаточном разогреве термоузла. Делаем следующее при включённом аппарате нажимаем одновременно кнопки [0] и [Прерывание] удерживаем в течении 5-7 секунд затем нажимаем [Старт]. Появляется окошко для входа в сервисный режим. Затем ищем пункт NVM read и write, заходим в это меню. Потом в поле значение [NVM] пишем значение ячейки 744-044, далее внизу набираем значение 0 наживаем [Save] затем в главном сервисном режиме Exit Clear Нажимаем на него потом ОК. Аппарат перезагрузится и ошибка исчезла, всё вернулось в рабочее состояние.» . но нет, не в моем случае, ошибка та же и ничего не изменилось, печь холодная выключаешь, включаешь, все так же, ошибка и печь холодная.
Я прозвонил лампы, термопредохранитель, все целое, предположил что печь не родная. Все что я смог найти на фьюзере это «CN-126K 21099-6QAV-1400022471»
Если печь не родная, но по посадочным встает как родня то схема подключения может отличаться?

2. Alexeuss 24.08.17 07:18

Я это читал и делал. В общем то об этом и написано выше

Имхо, пора поискать питание печки, благо схема его управления невелика.

Try to replace the fuser drive link ass’y 012K94820

Источник

Fault Codes 058-310 to 058-313, 059-326, 010-333 to 010-335, and 010-338, 010-339: Fuser Thermal Error

Product support for: VersaLink C400 / C405 Family, VersaLink C400, VersaLink C405

Article Id: 2041163 | Published: 06/17/2019

Materials required:

  • Cloth to wipe hands
  • New Fuser Cartridge

Step 1: Power the Printer Off then On

CAUTION: Do not plug or unplug the power cord while the printer is powered on.

NOTE: The images in this procedure are for demonstration purposes only and may not specifically match your printer model; colors, icons, and other minor differences may exist.

  1. At the printer control panel, press the Power/Wake button.
  2. Touch Power Off.
    • If the printer does not respond to a single press of the Power/Wake button, then press and hold the button for 5 seconds. A Please Wait message appears as the printer powers down.
  3. After 10 seconds, the touch screen goes dark and the Power/Wake button flashes until the printer powers down. To power on the printer, press the Power/Wake button.

  • Try your job again. If the problem persists, continue with the next step.
  • Step 2: Replace the Fuser and Reset the Counter

    CAUTION: Wait at least 40 minutes for the Fuser to cool down before attempting this procedure. The Fuser and surrounding area may become hot during operation. To avoid injury, be careful while working in this area.

    Unplug the power cord from the back of the printer and the ethernet cable, if attached.

  • Push down on the release button, and lower the Rear Door into the open position.
  • Push up on the release button on the left side of the Fuser to unlock the Fuser. Keep the release button pressed in, and then pull the Fuser out of the printer.

    Place the old Fuser aside for recycling.

    IMPORTANT: Place any suspected defective cartridge that is removed from the printer in protective wrapping/packaging material for situations where it may still be a functioning cartridge. If you do not have the original packaging material, use the packaging from the new cartridge.

    Remove the new Fuser from the packaging.

    Line up the knobs on either side of the new Fuser with the slots in the printer, and then push the Fuser into the printer until the Fuser clicks into place.

  • Close the Rear Door.
  • Plug in the power cord on the back of the printer and the ethernet cable, if required, and then power on the printer.
  • Select the Home button, then select the Device App button.
  • Select the Supplies button.
  • To reset the counter, touch Fuser and select Reset in the top, right of the screen, then exit out of any screens.
  • Try your job again. If the problem persists, contact Support for additional assistance.
  • Источник

    How to Fix 010-331 010-333 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

    Posted by Xwk Tech on Sep 18, 2019

    010-331, 010-333 Over Temperature Fail RAP

    BSD-ON: BSD 10.2 Fusing Heat Control (1 of 2)

    010-331 Fuser thermistor detected temperature monitor AD value that is the specified value or more 10 consecutive times.
    010-333 Fuser NC sensor detected a temperature that is the specified value or more 10 consecutive times.

    Initial Actions

    WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

    • Remove the fuser. Check whether foreign substances or paper is wound around the heat roll.
    • Ensure J416 on the drive PWB is securely connected.

    Procedure

    Perform the steps that follow:

    1. Install new components as necessary:

    • LVPS, PL 1.10 Item 3.
    • Fuser, PL 10.05 Item 2.
    • Drive PWB, PL 1.10 Item 4.
    • ESS PWB, PL 3.10 Item 6.

    2. To clear this fault, first remove the cause, then reset the value of NVM location 744-002 (Error Detection Flag) to 0. Switch off, then switch on the machine, GP 10.

    NOTE: The relationship between the displayed value and the sensor that detected the high temperature error is as follows:

    • 0: Normal.
    • 1: High temperature error of heat roll nc sensor.
    • 2: High temperature error of heat roll thermistor.
    • 3: Abnormal temperature increase of heat roll NC sensor, heat roll thermistor.
    • 4: Hardware high temperature error of heat roll thermistor.

    **This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

    You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

    Toner Chip (For North America and West Europe Region):

    Toner Chip (For South America and East Europe Region):

    Toner Chip (For Metered Machine):

    Источник

    010 333 xerox error

    Just wanna say a big thank you Neme Amber for introducing me to Dr Emmanuel the great HERBALIST that helped me prepare home remedies that cured my herpes (HSV 2).
    I was infected with HSV 2 for the past two years and i was unable to get a better job cos all the company i was to get employed checked our blood test and found out that i was positive to GENITAL HERPES and i loosed employmAent.
    So i was desperate to get a cure so that i can live normal and get my job training.
    i earlier made some research and i contacted some doctors online but they keep on asking for money for courier after that they’ll tell you that tax and so more so i became broke and frustrated.
    One day i was less busy so i decided to make latest research on herpes cure and i found a site were everyone was talking about DR Emmanuel and herbs ability to cure herpes.
    So i discussed with Neme Amber and she explained to me that its very easy working with Dr Emmanuel so i contacted DR Emmanuel via email ( nativehealthclinic@gmail.com ) and he helped me just as he has helped others now im cured and different medical centers has tested me and approved me cured.
    so i decided to thank Neme Amber cos she made it possible for me.
    and i can also assure you that he can also help you. so if you need the service of DR emmanuel, ill put his details here so that you can easily get in touch wif him.
    his email: nativehealthclinic@gmail.com or WhatsApp him at +2348140073965.
    my Name is Grace from US,once again thanks to Neme Amber. im fucking hapy.. u
    Dr Emmanuel YouTube like at https://www.youtube.com/channel/UCpUsOO5kNWlqOYzaWgtQuHQ

    I want to share this great testimony to the world on how Dr VOODOO cure me from HSV1&2 with his herbs, I was nervous when i first contact him about the cure for HSV but i decided to give him a try because i was desperate to get cured and be free from HSV. Dr VOODOO prepared the remedy and sent it to me through UPS,which I use just the way Dr VOODOO instructed me and thank God today I am a beneficiary to this cure and I went back to the hospital after 7 days of taking the herbs and I tested HSV1&2 Negative. So I will tell you all who are looking for a cure to his/her HSV1&2 that Dr VOODOO took research before he could finally get the solution to it and a lot of people are benefiting from him right now. He also cured my friend from HPV. Dr VOODOO heals with natural herbs. Please I urge you to contact him now through his email address: voodoospelltemple66@gmail.com or call and WhatsApp him on +2348140120719. He is capable of curing HIV/AIDS, HERPES, HPV, HSV1&2, CANCER of all kinds, DIABETES and so many other infections.

    Hello, I want to write a little review about the good work of doctor ehiaguna, who cured me from HSV 1&2 for just 2 week with his herbal medicine, I never believe I can be cured again and have a good life like others, I always regretted the day I got diagnose with this virus, I become lost of hope when my doctor told me there is no cure for it, Well I am so grateful for my helper who get me cured with his herbal medicine, I went online in search of anything that can help me because I can’t deal with it forever so I found dr ehiaguna email drehiaguna@gmail.com on a Facebook of someone who was cured by him,of the same herpes, so I quickly contacted him for help and explained all my pains to him, he told me not to worry about it there is a cure for real, I never believe until he sent me the herbs when I ordered for it and I got it within 5 working days that is how I took the medicine for 2 weeks and the following week I went for a test just to confirm I was 100% cured from this sickness what a miracle in my life, I am so happy right now, and forever greatful, you can also get in contact with him if you have such sickness through his whatsapp +2348073908953 you can email him:: drehiaguna@gmail.com visit his website. https://effectiveherbalcurehome.blogspot.com/ God bless you

    i am so glad to write this article today to tell the world how Dr. Ohunyom cured my HPV virus that have been in my body since five years ago, ever since then my life has been in complete,i have used so many drugs that was prescribed to me by several doctors,but it didn’t cure my HPV VIRUS neither did it reduce the pain, i was checking for solution on the internet then miraculously came across Dr. Ohunyom the powerful herbalist that cure HPV INFECTION,then i contacted his email, i explained everything to him and he prepared a herbal cure and send it to me that was how i got cured from HPV disease totally after receiving his herbal medicine, so my friends viewers why waiting and be suffering with this HPV virus when there is someone like Dr. Ohunyom that can get you cured completely. you can contact his Email via:drohunyom@gmail.com and also WhatsApp him +2349060579973 And He also have herbs medicine to cured the following diseases; eczema,urethra wart,chronic problems.Herpes, Cancer, Als,Hepatitis, Diabetes, HPV,Infections,ulcer ETC

    Great! It works also on Xerox 7120, i was the same problem and manged it.

    I’m living in Jamaica and have a Xerox 7120 and it’s not Booting, and whenever I try to switch it of it won’t switch of, I have to use the main power switch to shut it down. Can anyone help me find the problem

    Xerox 7125 Work Center Printer Error 010-333 thanks for share this all detail about for printer support.

    Thank you for sharing this wonderful blog. Canon Printer Tech Support Number

    Help me mr. Xerok C5500 problem fusing temp roll low, help me code chain link to higt temperature

    Hi Friends i am so glad to writing this article today to tell the world how Dr voodoo cured my HSV VIRUS,i have been detected with HSV-1 AND HSV-2 since five years ago, ever since then my life has been in complete bizarre and agony,i have used so many drugs that was prescribed to me by several doctors,but it didn’t cure my HSV VIRUS neither did it reduce the pain,until a certain i was checking for solution in the internet,then miraculously came across Dr voodoo the powerful herbalist that cure numerous individuals HSV-1 AND HSV-2 INFECTION,then i contacted his whatsApp number at +2348140120719 or email: voodoospelltemple66@gmail.com i explained everything to him and prepared a cure that cure my HSV-1 AND HSV-2 disease totally after receiving his herbal medicine, so my friends viewers why wait and be suffer when there is someone like Dr voodoo that can cure any disease HIV/ CANCER/ HEPATITIS B VIRUS, you can contact his via : voodoospelltemple66@gmail.com or WHATSAPP +2348140120719

    Like it So much keep posting like this. Avast Antivirus Support

    Nice Post!
    Securitytech offering guarantee customer support and providing Anti Virus, Computer, Browser, Email and Printer tech support service.Call us @ +1-8779336146
    Dell Printer Support
    Antivirus Tech Support
    Panda Antivirus Support
    Avg Antivirus Support
    FireWall Configurations Support

    This is a nice post in an interesting line of content. Thanks for sharing this article, great way of bring such topic to discussion.

    Dell Printer Device set and configure with laptop. Dell customer support service avilable in the USA contact easily. Just a call +1877-219-1215 for quick Help.
    Xerox Printer Support
    Xerox Printer Customer service
    Xerox Printer Support phone Number
    Xerox Printer help Service

    Nice blog! Thanks for sharing valuable blog
    If you are still facing any issues like paper jam, error code, installations, etc. Call us 1-800-293-9401 for Canon Printer Customer Support Number.
    Canon Printer Customer Support Number
    Canon Printer Customer Support Number

    Hi…, i m Elena dsouza you have write Nice post! You are sharing amazing information through your blog. I am a big fan of your excellent writing skills. And for more information and technical Support services about HP Printer call US Support For HP Printer | Number +1 877 301 0214, HP Printers Support | HP Printers Support Number

    Are you looking for printer maintenance kits in USA? Then InkJet Parts is one of the best option you have.

    I have same problem with 7030 machine give me any solution for that.

    Thank you for your great post. I’ve tried 744-004 as sm said and 744-220 with no effect. I’ll try this.

    If you need support or system software of Xerox and Konica maybe I can help you. comercial@ofiexpertos.com

    Resolving paper jam error on Epson laser printer can be an easy process if done right for that the user should open the printer machine the user should further remove the paper further the user should check the print cartridge, for further information it is advisable to get in touch with the team of experienced technicians at Epson laser printer support.
    Contact No.:
    USA: +1-209-813-2790
    UK: +44-800-368-9067
    Website: http://www.epson-contact.com/epson-laser-printer-support/
    Address: United State, United Kingdom

    Very significant Information for us, I have think the representation of this Information is actually superb one. This is my first visit to your site. Xerox Printer Auckland

    my photo machine is fujixerox 3605. It show error code 010-333. Please help me! Thanks you sir.

    Источник

    • Xerox 7132 error 010-333

      Hi everybody,
      I have a Xerox 7132 giving me an error code 010-333, I already replace the fuser with a fuser from another machine and I reset the fuser under supplies, but I’m still getting the code.
      I really need some help.
      Thanks.

    • Quote:


      Originally Posted by copytechusa
      View Post

      Hi everybody,
      I have a Xerox 7132 giving me an error code 010-333, I already replace the fuser with a fuser from another machine and I reset the fuser under supplies, but I’m still getting the code.
      I really need some help.
      Thanks.


      Ensure that NVM location 744-004 is set to zero (0). If the problem continues, replace the Fuser Unit

    • Quote:


      Originally Posted by xeroxsharp
      View Post

      Ensure that NVM location 744-004 is set to zero (0). If the problem continues, replace the Fuser Unit


      Thanks for your reply.
      I already check that and is set to zero (0) and I also change the fuser with a fuser from another machine that was working and I still have the same code.
      The code is still there.
      Please help, I’ve been dealing with this for over a week.
      Thanks.

    • Quote:


      Originally Posted by copytechusa
      View Post

      Thanks for your reply.
      I already check that and is set to zero (0) and I also change the fuser with a fuser from another machine that was working and I still have the same code.
      The code is still there.
      Please help, I’ve been dealing with this for over a week.
      Thanks.


      1. Follow 010-333 Fuser Center Thermistor Overtemp RAPfirst to check all elements without replacing parts at this point if not needed.
      2. Check NVM location 744-004. If value is different than 0 (like a 3), set it back to 0.
      3. Before replacing any parts; Insure that the NVM sheet is present and filled. Initialise the MCU Section 6 / Diagnostics (Others) Initialize NVM, select IOT.
      4. If problem comes back, per Note in the RAP replace Fuser Assembly PL 7.1 item 10.
      5. Per RAP, If the problem persists, replace the Power Unit PL 11.1 item 7. If the problem persists, replace the MCU PWB PL 11.1 item 22.

      1. Access Diagnostic Routines.
        <LI id=svc.elan.0000097953>Enter UI Diagnostics (Entering UI Diagnostics in UI Diagnostic Mode).
      2. Access Diagnostic Routines (Accessing Diagnostic Routines in UI Diagnostic Mode).
        <LI id=svc.elan.0000038408>Select Maintenance/Diagnostics.
        <LI id=svc.elan.0000038412>Select Initialize NVM.
        <LI id=svc.elan.0000038421>Select the desired item, then press the Start button.
      3. After initialization is complete, use the data accumulated in Initial Actions to restore the machine to its previous configuration
    • 1 Attachment(s)

      See Attachment

    • How to set NVM to 0?

      What is NVM? where can I locate that?
      I have the same problem and I’m hoping I can solve this by setting the NVM to 0.

      Thank you.

    • Quote:


      Originally Posted by copytechusa
      View Post

      Hi everybody,
      I have a Xerox 7132 giving me an error code 010-333, I already replace the fuser with a fuser from another machine and I reset the fuser under supplies, but I’m still getting the code.
      I really need some help.
      Thanks.


      Replace the fuser unit with a NEW (now used) and reset nvm 744-004 to 0. Some xerox machines don’t clear fuser error codes without replacing the fuser with a new unit. If problem still persists, then it could be a faulty low voltage power supply (LVPS) which means, you need a xerox tech to fix it :cool:

    • FIRST CHECK THE VOLAGE SUPPLIES FROM THE LVPS YOU MUST FIND 220V OR 110V IN THE PIN J5-3 AND J5-4 IN LVPS, IF YOU WILL NOT FIND THIS VOLTAGE REMPLACE LVPS
      IF THE VOLTAGE FOND ? CHECK THE VOLTAGE FROM THE FUSER CONNECTOR YOU MEST FIND 22V IN TNE PIN 3 AND 6 IF YOU WILL NOT FIND THE VOLTAGE VERIFIE an open circuit or a short circuit FROM THE LVPS TO FUSER CONNECTOR IF ALL DOES OK REMPLACE MCU PWB

    • Re: Xerox 7132 error 010-333

      am also having that same problem but i dont know how to clear the error code and how to get to the nvm please can anyone teach me that please


    View Full Version : Xerox 7132 error 010-333


    Google

    Custom Search

    copytechusa

    02-23-2009, 11:57 PM

    Hi everybody,
    I have a Xerox 7132 giving me an error code 010-333, I already replace the fuser with a fuser from another machine and I reset the fuser under supplies, but I’m still getting the code.
    I really need some help.
    Thanks.


    xeroxsharp

    02-24-2009, 06:18 AM

    Hi everybody,
    I have a Xerox 7132 giving me an error code 010-333, I already replace the fuser with a fuser from another machine and I reset the fuser under supplies, but I’m still getting the code.
    I really need some help.
    Thanks.

    Ensure that NVM location 744-004 is set to zero (0). If the problem continues, replace the Fuser Unit


    copytechusa

    02-24-2009, 01:24 PM

    Ensure that NVM location 744-004 is set to zero (0). If the problem continues, replace the Fuser Unit

    Thanks for your reply.
    I already check that and is set to zero (0) and I also change the fuser with a fuser from another machine that was working and I still have the same code.
    The code is still there.
    Please help, I’ve been dealing with this for over a week.
    Thanks.


    xeroxsharp

    02-24-2009, 02:23 PM

    Thanks for your reply.
    I already check that and is set to zero (0) and I also change the fuser with a fuser from another machine that was working and I still have the same code.
    The code is still there.
    Please help, I’ve been dealing with this for over a week.
    Thanks.

    Follow 010-333 Fuser Center Thermistor Overtemp RAP (pws://file/xerox/edoc/wc7132/chtml/svc.elan.0000254964.htm)first to check all elements without replacing parts at this point if not needed.
    Check NVM location 744-004. If value is different than 0 (like a 3), set it back to 0.
    Before replacing any parts; Insure that the NVM sheet is present and filled. Initialise the MCU Section 6 / Diagnostics (Others) Initialize NVM (pws://file/xerox/edoc/wc7132/chtml/svc.elan.0000038377.htm), select IOT.
    If problem comes back, per Note in the RAP replace Fuser Assembly PL 7.1 item 10 (pws://file/xerox/edoc/wc7132/chtml/svc.elan.PL7.1.htm).
    Per RAP, If the problem persists, replace the Power Unit PL 11.1 item 7 (pws://file/xerox/edoc/wc7132/chtml/svc.elan.PL11.1.htm). If the problem persists, replace the MCU PWB PL 11.1 item 22 (pws://file/xerox/edoc/wc7132/chtml/svc.elan.PL11.1.htm).

    Access Diagnostic Routines.
    <LI id=svc.elan.0000097953>Enter UI Diagnostics (Entering UI Diagnostics in UI Diagnostic Mode (pws://file/xerox/edoc/wc7132/chtml/svc.elan.0000010122.htm)).
    Access Diagnostic Routines (Accessing Diagnostic Routines in UI Diagnostic Mode (pws://file/xerox/edoc/wc7132/chtml/svc.elan.0000010122.htm)).
    <LI id=svc.elan.0000038408>Select Maintenance/Diagnostics.
    <LI id=svc.elan.0000038412>Select Initialize NVM.
    <LI id=svc.elan.0000038421>Select the desired item, then press the Start button.
    After initialization is complete, use the data accumulated in Initial Actions to restore the machine to its previous configuration


    XeroxTechBrazil

    03-03-2009, 05:43 AM

    See Attached File


    rAhMzKi

    05-27-2009, 10:54 AM

    What is NVM? where can I locate that?
    I have the same problem and I’m hoping I can solve this by setting the NVM to 0.

    Thank you.


    TechMate

    06-01-2009, 04:24 AM

    Hi everybody,
    I have a Xerox 7132 giving me an error code 010-333, I already replace the fuser with a fuser from another machine and I reset the fuser under supplies, but I’m still getting the code.
    I really need some help.
    Thanks.

    Replace the fuser unit with a NEW (now used) and reset nvm 744-004 to 0. Some xerox machines don’t clear fuser error codes without replacing the fuser with a new unit. If problem still persists, then it could be a faulty low voltage power supply (LVPS) which means, you need a xerox tech to fix it :cool:


    abdou

    06-04-2009, 10:43 PM

    FIRST CHECK THE VOLAGE SUPPLIES FROM THE LVPS YOU MUST FIND 220V OR 110V IN THE PIN J5-3 AND J5-4 IN LVPS, IF YOU WILL NOT FIND THIS VOLTAGE REMPLACE LVPS
    IF THE VOLTAGE FOND ? CHECK THE VOLTAGE FROM THE FUSER CONNECTOR YOU MEST FIND 22V IN TNE PIN 3 AND 6 IF YOU WILL NOT FIND THE VOLTAGE VERIFIE an open circuit or a short circuit FROM THE LVPS TO FUSER CONNECTOR IF ALL DOES OK REMPLACE MCU PWB


    mayorg

    01-22-2016, 11:01 AM

    am also having that same problem but i dont know how to clear the error code and how to get to the nvm please can anyone teach me that please


    Google

    Custom Search

    Powered by vBulletin® Version 4.2.5 Copyright © 2023 vBulletin Solutions Inc. All rights reserved.

    010-331, 010-333 Over Temperature Fail RAP

    BSD-ON: BSD 10.2 Fusing Heat Control (1 of 2)

    010-331 Fuser thermistor detected temperature monitor AD value that is the specified value or more 10 consecutive times.
    010-333 Fuser NC sensor detected a temperature that is the specified value or more 10 consecutive times.

    Initial Actions

    WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

    • Remove the fuser. Check whether foreign substances or paper is wound around the heat roll.
    • Ensure J416 on the drive PWB is securely connected.

    Procedure

    Perform the steps that follow:

    1. Install new components as necessary:

    • LVPS, PL 1.10 Item 3.
    • Fuser, PL 10.05 Item 2.
    • Drive PWB, PL 1.10 Item 4.
    • ESS PWB, PL 3.10 Item 6.

    2. To clear this fault, first remove the cause, then reset the value of NVM location 744-002 (Error Detection Flag) to 0. Switch off, then switch on the machine, GP 10.

    NOTE: The relationship between the displayed value and the sensor that detected the high temperature error is as follows:

    • 0: Normal.
    • 1: High temperature error of heat roll nc sensor.
    • 2: High temperature error of heat roll thermistor.
    • 3: Abnormal temperature increase of heat roll NC sensor, heat roll thermistor.
    • 4: Hardware high temperature error of heat roll thermistor.

    **This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

    You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

    Toner Chip (For North America and West Europe Region):

    • 106R03741 106R03744 106R03743 106R03742
    • 106R03757 106R03760 106R03759 106R03758
    • 106R03737 106R03740 106R03739 106R03738

    Toner Chip (For South America and East Europe Region):

    • 106R03749 106R03752 106R03751 106R03750
    • 106R03745 106R03748 106R03747 106R03746
    • 106R03765 106R03768 106R03767 106R03766

    Toner Chip (For Metered Machine):

    • 106R03733 106R03736 106R03735 106R03734

    Drum Chip:

    • 113R00780 113R00782


    Просмотр полной версии : Прогблема с Xerox 7232


    Пожалуйста, помогите запустить Xerox 7232, при включении вылетает ошибка 010-333, аппарат новый, вскрыли, распечатали, включили и вот такая ерунда :(


    Xerox WorkCentre 7132 error 010-333
    14.01.2008

    На аппарате Xerox WorkCentre 7132 появилась ошибка 010-333, после этого аппарат не функционирует должным образом.

    Ответ:

    Данная ошибка означает, что температура фьюзера не достигла нужного значения. Отключите и включите аппарат. Если после этого ошибка будет повторяться, обратитесь в сервис-центр.

    гугл рулит?


    А решения проблемы как такового нет!!! Даже сервисники с ней подвисли!


    Решение проблемы — ремонт или замена по гарантии.

    Даже сервисники с ней подвисли!

    Отказались чинить или оформлять акт невозможности ремонта?


    Сервисники не могут его запустить/отремонтировать и акт писать тоже отказываются. Из-за того, что нет акта, поставщик его у нас обратно не забирает для обмена.

    добавлено через 1 минуту
    Скажем так, я уже нашел причину проблемы на различных форумах, но устранить её должны сервисники, я так понимаю программатором. Это софтовый глюк, необходимо произвести сброс NVM к заводским настройкам.

    добавлено через 3 минуты
    eap

    С этим аппаратом вообще форс-мажор получился капитальный, вот вся история покупки:

    Вообщем накипело, слов нет, пусть люди знают отношение дилеров, сервиса и самой компании Xerox к клиентам в г. Краснодаре. И так, всё по порядку.
    31 марта сего года был куплен принтер-копир Xerox WC 7232, был доставлен в наш офис поставщиком — официальным реселлером Xerox.
    Был поднят на 3й этаж, открыта коробка, в которой была обнаружена инструкция пользователя и вкладыш по правильной распаковке и запуску аппарата (никаких предупреждений в инструкции или в руководстве по запуску о том, что аппарат должен запускать сервисный инженер компании Xerox небыло!!!).
    После удаления всей транспортировочной упаковки, было произведено включение аппарата.
    Странным показалось то, что аппарат не сделал механический тест после первого включения, хотя должен был.
    Далее был введен Startup PIN и тут же на дисплее аппарата высветилась ошибка с кодом 010-333 и просьбой обратиться в сервисный центр.
    Аппарат был выключен и был сделан звонок по горячей линии Xerox. Там мне было сказано, что аппарат должен запускать сервисный инженер и были очень удивлены, что поставщик не уведомил нас об этом.
    Я позвонил поставщику, он тоже был удивлен, что аппарат должен запускать сервисный инженер.
    Нашли ОДИН более менее вменяемый сервис, который прислал двух специалистов. Эти специалисты в течении 2х часов!!! не смогли разобраться ни с причиной ошибки ни выяснить её код, почесали репу и уехали.
    Итог: по сей день аппарат простаивает, а сервисные центры Краснодара не знают что делать.
    Если есть какие нибудь советы, буду очень признателен за помощь.


    vBulletin® v3.8.5, Copyright ©2000-2023, Jelsoft Enterprises Ltd.

    Понравилась статья? Поделить с друзьями:
  • Xerox 5335 ошибка 005 123
  • Xerox 7120 ошибка 016 405
  • Xerox 7120 ошибка 092 314
  • Xerox 5330 ошибка 016 405
  • Xerox 7120 ошибка 092 312