Xerox 7100 ошибка 010 338

Thanks Thanks:  0

Likes Likes:  0

Dislikes Dislikes:  0

  1. 09-18-2017


    #1

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Phaser 7100N with error 010-338 «fuser unit fail»

    Customer called with error 010-338 on Phaser 7100n. Customer said he just changed fuser unit to get rid of error but still has 010-338.Any help is appreciated. Is there a reset procedure on this machine that is necessary
    after fuser unit is changed. I asked cust. if sure it was a new unit and he said yes. Any advice is appreciated. I will check SM in meantime to see if I see anything though I thought I saw this was a fuser unit fail error but
    did not see a service mode reset procedure for this. Frank/ActionPhotocopy


  2. 09-18-2017


    #2

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Nothing to do with the fuser.
    Check for toner low or empty


  3. 09-18-2017


    #3

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Hi Adi . Thank you for your info. It is a little confusing because the Phaser 7100 service manual on page 2-83 states that error 010-338 is a Fuser Unit On Time Fail Error.

    Originally the customer called and said he had been using the machine although there was a lot of toner spillage but machine was working. Then change toner cartridge(BLack) message.
    After customer changed cartridge he got the 010-338 error. I told him to make sure it was OEM before calling for service. he bought OEM and still had error. I saw info in service manual and told customer
    he would probably need fuser unit. He ordered it himself from amazon.com and called this morning to say he still had error. As I am writing this customer just called to say he is out of office but thinks error
    has disappeared as machine is asking for loading of paper. He will call tomorrow. Frank


  4. 09-18-2017


    #4

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    It is machine software glitch.
    Was ( or is ) technical bulletin about this on Eureka.


  5. 09-18-2017


    #5

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Customer supposedly changed black toner for oem. Anyway he will call me tomorrow to let me know if working now


  6. 09-21-2017


    #6

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    customer says machine is now working


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

Thanks Thanks:  0

Likes Likes:  0

Dislikes Dislikes:  0

  1. 09-18-2017

    #1

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    45

    Thumbs up Phaser 7100N with error 010-338 «fuser unit fail»

    Customer called with error 010-338 on Phaser 7100n. Customer said he just changed fuser unit to get rid of error but still has 010-338.Any help is appreciated. Is there a reset procedure on this machine that is necessary
    after fuser unit is changed. I asked cust. if sure it was a new unit and he said yes. Any advice is appreciated. I will check SM in meantime to see if I see anything though I thought I saw this was a fuser unit fail error but
    did not see a service mode reset procedure for this. Frank/ActionPhotocopy


  2. 09-18-2017

    #2

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Nothing to do with the fuser.
    Check for toner low or empty


  3. 09-18-2017

    #3

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Hi Adi . Thank you for your info. It is a little confusing because the Phaser 7100 service manual on page 2-83 states that error 010-338 is a Fuser Unit On Time Fail Error.

    Originally the customer called and said he had been using the machine although there was a lot of toner spillage but machine was working. Then change toner cartridge(BLack) message.
    After customer changed cartridge he got the 010-338 error. I told him to make sure it was OEM before calling for service. he bought OEM and still had error. I saw info in service manual and told customer
    he would probably need fuser unit. He ordered it himself from amazon.com and called this morning to say he still had error. As I am writing this customer just called to say he is out of office but thinks error
    has disappeared as machine is asking for loading of paper. He will call tomorrow. Frank


  4. 09-18-2017

    #4

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    It is machine software glitch.
    Was ( or is ) technical bulletin about this on Eureka.


  5. 09-18-2017

    #5

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Customer supposedly changed black toner for oem. Anyway he will call me tomorrow to let me know if working now


  6. 09-21-2017

    #6

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    customer says machine is now working


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

BSD-ON:

BSD 10.1 — Fusing Heat Control

After the Main Lamp turned On during warm up, the Control Thermistor did not detect

READY temperature within the specified time.

After the Main Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the empty rotation started, the Control Thermistor did not detect the empty rotation

finishing temperature within the specified time.

After the Main Lamp turned On during printing, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during printing, the Control Thermistor did not detect a spe-

cific temperature within the specified time.

Initial Actions

Voltage Supply

Indoor Temperature

Procedure

NOTE: When this fault occurs, NVM location 744-005 is set to 1, 2, or 3, depending on the

fault. You must reset this location to 0 in order to clear the fault.

Check for paper on the Fuser. The Fuser has no paper wrapped round it.

Y

N

Remove the paper.

Check the installation of the Fuser Unit. The Fuser Unit is securely installed.

Y

N

Install the Fuser Unit securely.

Remove the Fuser Unit. Check the conductivity of the contact points of the Thermostat. The

contact points are connected.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Main Lamp between J621-6 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Main Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Sub Lamp between J621-2 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Sub Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Control (Center) Thermistor between J621-5 and J621-1

10.1). There is no open circuit in the Center STS and the resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

(PL

7.1).

A

Initial Issue

WorkCentre 5335 Family Service Documentation

A

Check the resistance of the Rear Thermistor between J621-7 and J621-3

resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

Check the wire between P/J411-B7 and J621-7 for an open circuit or a short circuit (

10.1). The wire between

short circuit.

Y

N

Repair the open circuit or short circuit.

Check the wire between

The wire between

Y

N

Repair the open circuit or short circuit.

Replace the Fuser Unit

If the problem persists, replace the MCU PWB

(BSD

07/2011

2-83

BUS Updated 12/2011

(PL

7.1).

P/J411

and

J621

is conducting without an open circuit or a

P/J414

and

P530

for an open circuit or a short circuit

P/J414

and

P530

conducts and if free of a short circuit.

(PL

7.1). If the problem persists, replace the AC Drive PWB

(PL

18.2).

(BSD

10.1). The

BSD

(BSD

10.1).

(PL

18.2)

Status Indicator RAPs

010-338

background image

Коды неисправностей

При сбое во время печати или неисправности аппарата на экран выводится код
неисправности. Если на экране отображается код неисправности, которого нет в
таблице ниже, или неисправность не удается устранить, выполнив указанные далее
действия, обратитесь в сервисный центр Xerox. При отображении кода
неисправности сбрасываются все данные печати на аппарате, а также данные в
его встроенной памяти.

Рекомендуемое решение

Вероятная причина

Код неисправности

Откройте передние дверцы и
убедитесь, что дверца
фьюзера закрыта.
Выключите и снова включите
аппарат.

Выдвижная секция фьюзера
открыта

010 300

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибки скорости ремня
фьюзера

010 310, 010 311, 010 312,

010 313, 010 314, 010 315,
010 316, 010 317, 010 318,

010 319, 010 321, 010 323,

010 324, 010 325, 010 326,

010 327, 010 328, 010 333,

010 334, 010 335, 010 336,

010 337, 010 338, 010 341,

010 342, 010 343, 010 344,

010 347, 010 348, 010 349,

010 350, 010 351, 010 352,

010 353, 010 354, 010 355,

010 356, 010 357, 010 369,

010 370, 010 371, 010 374,

010 379, 010 380, 010 386,

010 387, 010 389

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибка температуры
фьюзера или фьюзер
отключен

010 360, 010 401

10-25

Печатная машина Xerox

®

Color 800/1000

Руководство пользователя

Устранение неисправностей

Thanks Thanks:  0

Likes Likes:  0

Dislikes Dislikes:  0

  1. 09-18-2017

    #1

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338 "fuser unit fail"


    Rep Power
    45

    Thumbs up Phaser 7100N with error 010-338 «fuser unit fail»

    Customer called with error 010-338 on Phaser 7100n. Customer said he just changed fuser unit to get rid of error but still has 010-338.Any help is appreciated. Is there a reset procedure on this machine that is necessary
    after fuser unit is changed. I asked cust. if sure it was a new unit and he said yes. Any advice is appreciated. I will check SM in meantime to see if I see anything though I thought I saw this was a fuser unit fail error but
    did not see a service mode reset procedure for this. Frank/ActionPhotocopy


  2. 09-18-2017

    #2

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Nothing to do with the fuser.
    Check for toner low or empty


  3. 09-18-2017

    #3

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338 "fuser unit fail"


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Hi Adi . Thank you for your info. It is a little confusing because the Phaser 7100 service manual on page 2-83 states that error 010-338 is a Fuser Unit On Time Fail Error.

    Originally the customer called and said he had been using the machine although there was a lot of toner spillage but machine was working. Then change toner cartridge(BLack) message.
    After customer changed cartridge he got the 010-338 error. I told him to make sure it was OEM before calling for service. he bought OEM and still had error. I saw info in service manual and told customer
    he would probably need fuser unit. He ordered it himself from amazon.com and called this morning to say he still had error. As I am writing this customer just called to say he is out of office but thinks error
    has disappeared as machine is asking for loading of paper. He will call tomorrow. Frank


  4. 09-18-2017

    #4

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    It is machine software glitch.
    Was ( or is ) technical bulletin about this on Eureka.


  5. 09-18-2017

    #5

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338 "fuser unit fail"


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Customer supposedly changed black toner for oem. Anyway he will call me tomorrow to let me know if working now


  6. 09-21-2017

    #6

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338 "fuser unit fail"


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    customer says machine is now working


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

BSD-ON:

BSD 10.1 — Fusing Heat Control

After the Main Lamp turned On during warm up, the Control Thermistor did not detect

READY temperature within the specified time.

After the Main Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the empty rotation started, the Control Thermistor did not detect the empty rotation

finishing temperature within the specified time.

After the Main Lamp turned On during printing, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during printing, the Control Thermistor did not detect a spe-

cific temperature within the specified time.

Initial Actions

Voltage Supply

Indoor Temperature

Procedure

NOTE: When this fault occurs, NVM location 744-005 is set to 1, 2, or 3, depending on the

fault. You must reset this location to 0 in order to clear the fault.

Check for paper on the Fuser. The Fuser has no paper wrapped round it.

Y

N

Remove the paper.

Check the installation of the Fuser Unit. The Fuser Unit is securely installed.

Y

N

Install the Fuser Unit securely.

Remove the Fuser Unit. Check the conductivity of the contact points of the Thermostat. The

contact points are connected.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Main Lamp between J621-6 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Main Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Sub Lamp between J621-2 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Sub Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Control (Center) Thermistor between J621-5 and J621-1

10.1). There is no open circuit in the Center STS and the resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

(PL

7.1).

A

Initial Issue

WorkCentre 5335 Family Service Documentation

A

Check the resistance of the Rear Thermistor between J621-7 and J621-3

resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

Check the wire between P/J411-B7 and J621-7 for an open circuit or a short circuit (

10.1). The wire between

short circuit.

Y

N

Repair the open circuit or short circuit.

Check the wire between

The wire between

Y

N

Repair the open circuit or short circuit.

Replace the Fuser Unit

If the problem persists, replace the MCU PWB

(BSD

07/2011

2-83

BUS Updated 12/2011

(PL

7.1).

P/J411

and

J621

is conducting without an open circuit or a

P/J414

and

P530

for an open circuit or a short circuit

P/J414

and

P530

conducts and if free of a short circuit.

(PL

7.1). If the problem persists, replace the AC Drive PWB

(PL

18.2).

(BSD

10.1). The

BSD

(BSD

10.1).

(PL

18.2)

Status Indicator RAPs

010-338

background image

Коды неисправностей

При сбое во время печати или неисправности аппарата на экран выводится код
неисправности. Если на экране отображается код неисправности, которого нет в
таблице ниже, или неисправность не удается устранить, выполнив указанные далее
действия, обратитесь в сервисный центр Xerox. При отображении кода
неисправности сбрасываются все данные печати на аппарате, а также данные в
его встроенной памяти.

Рекомендуемое решение

Вероятная причина

Код неисправности

Откройте передние дверцы и
убедитесь, что дверца
фьюзера закрыта.
Выключите и снова включите
аппарат.

Выдвижная секция фьюзера
открыта

010 300

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибки скорости ремня
фьюзера

010 310, 010 311, 010 312,

010 313, 010 314, 010 315,
010 316, 010 317, 010 318,

010 319, 010 321, 010 323,

010 324, 010 325, 010 326,

010 327, 010 328, 010 333,

010 334, 010 335, 010 336,

010 337, 010 338, 010 341,

010 342, 010 343, 010 344,

010 347, 010 348, 010 349,

010 350, 010 351, 010 352,

010 353, 010 354, 010 355,

010 356, 010 357, 010 369,

010 370, 010 371, 010 374,

010 379, 010 380, 010 386,

010 387, 010 389

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибка температуры
фьюзера или фьюзер
отключен

010 360, 010 401

10-25

Печатная машина Xerox

®

Color 800/1000

Руководство пользователя

Устранение неисправностей

Thanks Thanks:  0

Likes Likes:  0

Dislikes Dislikes:  0

  1. 09-18-2017

    #1

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Phaser 7100N with error 010-338 «fuser unit fail»

    Customer called with error 010-338 on Phaser 7100n. Customer said he just changed fuser unit to get rid of error but still has 010-338.Any help is appreciated. Is there a reset procedure on this machine that is necessary
    after fuser unit is changed. I asked cust. if sure it was a new unit and he said yes. Any advice is appreciated. I will check SM in meantime to see if I see anything though I thought I saw this was a fuser unit fail error but
    did not see a service mode reset procedure for this. Frank/ActionPhotocopy


  2. 09-18-2017

    #2

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Nothing to do with the fuser.
    Check for toner low or empty


  3. 09-18-2017

    #3

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Hi Adi . Thank you for your info. It is a little confusing because the Phaser 7100 service manual on page 2-83 states that error 010-338 is a Fuser Unit On Time Fail Error.

    Originally the customer called and said he had been using the machine although there was a lot of toner spillage but machine was working. Then change toner cartridge(BLack) message.
    After customer changed cartridge he got the 010-338 error. I told him to make sure it was OEM before calling for service. he bought OEM and still had error. I saw info in service manual and told customer
    he would probably need fuser unit. He ordered it himself from amazon.com and called this morning to say he still had error. As I am writing this customer just called to say he is out of office but thinks error
    has disappeared as machine is asking for loading of paper. He will call tomorrow. Frank


  4. 09-18-2017

    #4

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    It is machine software glitch.
    Was ( or is ) technical bulletin about this on Eureka.


  5. 09-18-2017

    #5

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Customer supposedly changed black toner for oem. Anyway he will call me tomorrow to let me know if working now


  6. 09-21-2017

    #6

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  "fuser unit fail"


    Rep Power
    46

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    customer says machine is now working


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

You are here: Home / error code / Xerox Phaser 7100 error and solving error codes

– Compatible Printer model: Xerox Phaser 7100
– Xerox Phaser 7100 Error Codes with quick guides:

  • Code: 010-105, 010-112
  • Description: Fuser Unit Exit Sensor Jam The Fuser Unit has failed due to one of the following problems. • After a paper that had stopped at the Registration position was transported again, the paper did not reach the Fuser Exit Sensor within the specified time. • After the Fuser Exit Sensor has detected a paper, the paper passed by the Fuser Exit Sensor before the specified time. • 010-105: Fuser Unit Exit Sensor On Jam • 010-112: Fuser Unit Exit Out Early Jam
  • Causes: • Fuser Motor (Fuser Drive Assembly), PL 4.2.16 • 2nd BTR (Transfer Roller), PL 4.3.18 • Registration Sensor, PL 5.1.3 • Registration Roller (Registration Chute Assembly), PL 5.1.1 • Registration Clutch, PL 5.1.11 • Exit Roller (Fuser Unit), PL 10.1.1 • Fuser Exit Sensor (Fuser Unit), PL 10.1.1 • Paper Handling Motor (Paper Handling Drive Assembly, PL 11.1.19 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the paper transport path Is there any debris on the paper transport path? Remove the debris. Go to step 2. 2. Check the installation of the Registration Roller (Registration Chute). Is the Registration Chute installed properly? Go to step 3. Reinstall the Registration Chute. 3. Check the Registration Roller (Registration Chute). Is the Registration Chute damaged? Replace the Registration Chute. Go to step 4. 4. Check the Registration Sensor operation. Perform DC330 Component Control [071-102] to check the operation of the Registration Sensor. Is the Registration Sensor operating properly? Go to step 5. Go to Sensor Troubleshooting. 5. Check the Registration Clutch operation. Perform DC330 Component Control [071-013] to check the operation of the Registration Clutch. Is the Registration Clutch operating properly? Go to step 6. Go to Registration Clutch. 6. Check the Paper Handling (P/H) Motor operation. Perform DC330 Component Control [071-009] to check the operation of the P/H Motor. Is the P/H Motor operating properly? Go to step 7. Go to Paper Handling Motor. 7. Check the Fuser Exit Sensor operation. Perform DC330 Component Control [071-104] to check the operation of the Fuser Exit Sensor. Is the Fuser Exit Sensor operating properly? Go to step 8. Go to Fuser Exit Sensor. 8. Check the Fuser Motor operation. Perform DC330 Component Control [010-001] to check the operation of the Fuser Motor. Is the Fuser Motor operating properly? Replace the MCU PWB. Go to Fuser Motor.
  • Code: 010-106
  • Description: Exit Off Jam After a paper has passed by the Registration Sensor, the paper did not pass by the Fuser Exit Sensor within the specified time.
  • Causes: • Fuser Motor (Fuser Drive Assembly), PL 4.2.16 • Fuser Exit Sensor (Fuser Unit), PL 10.1.1 • Exit Roller (Fuser Unit), PL 10.1.1 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the paper transport path Is there any debris on the paper transport path? Remove the debris. Go to step 2. 2. Check the Fuser Unit. Is the Fuser Unit damaged? Go to step 3. Reinstall the Fuser Unit. 3. Check the Fuser Exit Sensor operation. Perform DC330 Component Control [071-104] to check the operation of the Fuser Exit Sensor. Is the Fuser Exit Sensor operating properly? Go to step 4. Go to Fuser Exit Sensor. 4. Check the Fuser Motor operation. Perform DC330 Component Control [010-001] to check the operation of the Fuser Motor. Is the Fuser Motor operating properly? Replace the MCU PWB. Go to Fuser Motor.
  • Code: 010-311 … 010-355
  • Description: • 010-311: Fuser Unit Heat Roll STS-1 Disconnection Fail • 010-319: Fuser Unit NC Sensor Differential Amp Fail • 010-328: Fuser Unit Warm Up Time Fail (Not Ready) • 010-331: Heat Roll STS Over Temperature Fail • 010-332: Heat Roll NC Sensor Disconnection Fail • 010-333: Heat Roll NC Sensor Over Temperature Fail • 010-334: Heat Roll NC Sensor Broken Fail • 010-335: Heat Roll NC Sensor Range Fail • 010-338: Fuser Unit On Time Fail • 010-339: Heat Roll NC Sensor Low Temperature Fail • 010-340: Fuser Unit Detached • 010-344: Heat Roll STS Sensor Low Temperature Fail • 010-345: Fuser Unit Hard Relay Off Fail • 010-346: Fuser Main Lamp Data Renewal Fail • 010-347: Fuser Sub Lamp Data Renewal Fail • 010-355: Fuser Cool Down Timeout Fail.
    Fuser Unit Fail The Fuser Unit has failed due to one of the following problems. • A differential circuit output error was detected between the detection output and the compensation output of the Fuser Unit NC Sensor. • When the Lamp On time meets the following conditions, where Tws °C is the temperature at the Wait state start time that is obtained at the NCSCenter. • The temperature monitor AD value of the STS-Front was detected to be higher than T[HITMP (2)] 3 times in a row. • During Warm Up Control, an abnormal detected temperature due to NC Sensor malfunction or poor contact was detected. • The Fuser Unit Main Lamp or Sub Lamp has been On continuously for longer than the setting time (NVM). • At the first Lamp Off after it was turned On, the NC temperature is continuously at EP_U4_LOW_NC °C or lower 8 or more times in a row. • The Thermistor disconnection detected. • At the first Heater OFF after it was turned On, the detected temperature at the edge STS is continuously at EP_U4_LOW_STS °C or lower 8 or more times in a row. • Notified at the moment the Relay is cut off from the circuit. • The detected temperature at the NC or the STS has not changed during this period, although the Main Lamp has been On continuously for 15 s or longer. • The Cool Down Mode has continued for EP_U4_COOL_TIME * 10 s or longer.
  • Causes: • DRW Fuser Harness Assembly, PL 4.1.7 • Fuser Unit, PL 10.1.1 • MCU PWB, PL 12.1.15 • AC PWB Assembly, PL 12.1.16 • LVPS PWB, PL 12.2.1 • Option Harness Assembly, PL 12.3.5
  • Troubleshooting Guides: 1. Check the installation of the Fuser Unit. Is the Drawer Connector between the Fuser Unit and Main Unit (P/J601) free of broken/bent pins, debris, burns, and etc., and the unit is installed properly? Go to step 2. Reinstall the Fuser Unit. 2. Check the connections between the Fuser Unit and MCU PWB, as well as between the Fuser Unit and AC PWB. Are the connectors P/J601, P/J459, and P/J503 connected securely? Go to step 3. Connect the connectors P/J601, P/J459, and P/J503. 3. Check the connection between the AC PWB and MCU PWB. Are the connectors P/J505 and P/J464 connected securely? Go to step 4. Connect the connectors P/J505 and P/J464. 4. Check the conductivity of the DRW Fuser Harness Assembly. Are the connections between P/J601<=> P/J459 and between P/J601 <=> P/J503 conducting properly? Go to step 5. Replace the DRW Fuser Harness Assembly. 5. Check the conductivity of the Option Harness Assembly. Is the connection between P/J505 <=> P/J464 conducting properly? Go to step 6. Replace the Option Harness Assembly. 6. Check the voltage supply (+5VDC) to the Fuser Unit. Measure the voltages between the MCU PWB GND <=> P/J459-5 and MCU PWB GND <=> P/J459-13. Is there a voltage (approx. +5VDC) output? Go to step 7. Go to +5VDC Power Troubleshooting. 7. Check the voltage supply (+3.3VDC) to the Fuser Unit. Measure the voltage between the MCU PWB GND <=> P/J459-1. Is there a voltage (approx. +3.3VDC) output? Go to step 8. Go to +3.3VDC Power Troubleshooting. 8. Replace the Fuser Unit. Does the error persist? Go to step 9. Troubleshooting complete. 9. Replace the AC PWB. Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 010-330
  • Description: Fuser Motor Fail The Fuser Motor rotation failure was detected.
  • Causes: • Front Harness Assembly, PL 4.2.11 • Fuser Motor (Fuser Drive Assembly), PL 4.2.16 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the Fuser Motor operation. Perform DC330 Component Control [010-001] to check the operation of the Fuser Motor. Is the Fuser Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of the Fuser Motor. Manually rotate the Fuser Motor. Does the Motor rotate? Reinstall the Fuser Drive Assembly. Go to step 3. 3. Check the connections between the Fuser Motor and MCU PWB, as well as between the Fuser Motor and LVPS PWB. Are the connectors P/J475, P/J4751, P/J4755, P/J524, P/J2711, and P/J242 connected securely? Go to step 4. Connect the connectors P/J475, P/J4751, P/J4755, P/J524, P/J2711, and P/J242. 4. Check the conductivity between the Fuser Motor and Relay Connector. Are the connections between P/J4755 <=> P/J4751 and between P/J242 <=> P/J2711 conducting properly? Go to step 5. Replace the Front Harness Assembly. 5. Check the conductivity between the Relay Connector and LVPS PWB. Is the connection between P/J2711 <=> P/J524 conducting properly? Go to step 6. Replace the Main Harness Assembly. 6. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4751 <=> P/J475 conducting properly? Go to step 7. Replace the Main Harness Assembly. 7. Check the voltage supply (+3.3VDC) to the Fuser Motor. Measure the voltage between the MCU PWB GND <=> P/J475-16. Is there a voltage (approx. +3.3VDC) output? Go to step 8. Go to +3.3VDC Power Troubleshooting. 8. Check the voltage supply (+24VDC) to the Fuser Motor. Measure the voltage between the LVPS PWB GND <=> P/J524-1. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Fuser Drive Assembly. Replace the LVPS PWB.
  • Code: 010-421, 010-906
  • Description: Fuser Unit Error – Life End The print volume has reached the specified value (Max value), which indicates that further usage will damage the Fuser Unit. • 010-421: Fuser Unit Life End Quality (operation can still continue) (quality lifespan has ended) (ERU) • 010-906: Fuser Unit Life End
  • Causes: • Fuser Unit, PL 10.1.1
  • Troubleshooting Guides: 1. Replace the Fuser Unit. 2. Perform DC135 HFSI to reset the following life counters: • Chain-Link 950-880: Fuser Unit PV • Chain-Link 950-884: Fuser Unit Heat Time
  • Code: 016-322
  • Description: JBA Accounting Data Full The cumulated accounting data reached the specified value (15,000).
  • Causes:
  • Troubleshooting Guides: 1. After an external Accounting Server has read the accounting data, turn the power Off and On. 2. If the problem persists, refer to Common System Fail“.
  • Code: 016-328
  • Description: Cont-MCU Cable Connection Fail The controller has detected a failure at its cable connection with the MCU PWB.
  • Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Check the connection of the cable between the I/P PWB and MCU PWB. 2. Replace the defective cable.
  • Code: 016-336
  • Description: Cont Program ROM Fail-2 Write command failure of Program ROM 1.
  • Causes: • I/P PWB, PL 12.4.1 • 1 GB DDR2 DIMM, PL 12.4.2
  • Troubleshooting Guides: 1. Remove and reinstall the I/P PWB ROM DIMM #1). 2. Replace the I/P PWB ROM DIMM #1). 3. Replace the I/P PWB PWB).
  • Code: 016-350
  • Description: Cont SEEP-ROM Diagnostic Fail-1 Unable to obtain the Product ID.
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Check the SEEP ROM contacts (for bent and broken pins, etc.). 2. Replace the I/P PWB PWB).
  • Code: 016-351
  • Description: Cont SEEP-ROM Diagnostic Fail-2 Error has occurred at W/R/V Test.
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Check the SEEP ROM contacts (for bent and broken pins, etc.). 2. Replace the I/P PWB PWB).
  • Code: 016-365
  • Description: Cont USB2.0 Device Fail Error has occurred at W/R/V Test of PCI Config Space or at W/R/V Test of internal registers.
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Remove and reseat all connectors on the I/P PWB. 2. If problem persists, replace the I/P PWB PWB).
  • Code: 016-372 … 016-382
  • Description: • 016-372: Cont HDD FileSystem Fail-A • 016-373: Cont HDD FileSystem Fail-B • 016-374: Cont HDD FileSystem Fail-C • 016-375: Cont HDD FileSystem Fail-D • 016-376: Cont HDD FileSystem Fail-E • 016-377: Cont HDD FileSystem Fail-F • 016-378: Cont HDD FileSystem Fail-G • 016-379: Cont HDD FileSystem Fail-H • 016-380: Cont HDD FileSystem Fail-I • 016-381: Cont HDD FileSystem Fail-J • 016-382: Cont HDD FileSystem Fail-P The HDD has failed due to one of the following problems. • The Boot Diag has detected an HDD logical error (partition A). • The Boot Diag has detected an HDD logical error (partition B). • The Boot Diag has detected an HDD logical error (partition C). • The Boot Diag has detected an HDD logical error (partition D). • The Boot Diag has detected an HDD logical error (partition E). • The Boot Diag has detected an HDD logical error (partition F). • The Boot Diag has detected an HDD logical error (partition G). • The Boot Diag has detected an HDD logical error (partition H). • The Boot Diag has detected an HDD logical error (partition I). • The Boot Diag has detected an HDD logical error (partition J). • The Boot Diag has detected an HDD logical error (partition P).
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Initialize the HDD (refer to DC355 Hard Disk Diag).

Xerox Phaser 7100 error and solving error codes

Solve Xerox Phaser 7100 Error codes

  • Code: 024-900
  • Description: Tray 1/ 2/ 3 Of Place Paper cannot be fed (paper path not available) as an upper Tray compared of the selected Paper Supply Tray is in [Removed] state. This fault occurs depending on the paper transport configuration of the engine.
  • Causes: • Tray 1 Paper Size Switch, PL 2.1.6 • Tray Assembly 250, PL 2.1.11 • Tray Assembly 550, PL 15.1.1 • Tray 2/3/4 Paper Size Switch, PL 15.1.5
  • Troubleshooting Guides: 1. Check to make sure all trays above the tray in use are properly installed. If it is check the Paper Size Switch in DC330 Component Control. If it works replace the Tray. If it doesn’t work, replace the Paper Size Switch. • Tray 1 Paper Size Switch • Tray 2/3/4 Paper Size Switch
  • Code: 024-910
  • Description: Tray 1 Error: Size Unknown When the paper length in Slow Scan direction is measured on the paper feed path, the detected size is different from the size detected by the Tray.
  • Causes: • Paper Size Switch, PL 2.1.6 • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation of the Tray. Is the Tray installed properly? Go to step 2. Install the Tray. 2. Check the paper Guide. Is the paper Guide in the Tray set correctly? Go to step 3. Set the paper Guide. 3. Check the Paper Size Switch operation. Perform DC330 Component Control to check the On/ Off operation of each Switch of the Paper Size Switch. • Switch 0 [071-106] • Switch 1 [071-107] • Switch 2 [071-108] • Switch 3 [071-109] Are the Switches working properly? Replace the MCU PWB. Go to step 4. 4. Check the connection between the Paper Size Switch and MCU PWB. Are the connectors P/J4653A and P/J465A connected securely? Go to step 5. Connect the connectors P/J4653A and P/J465A. 5. Check the conductivity between the Paper Size Switch and MCU PWB. Is the connection between P/J4653A <=> P/J465A conducting properly? Replace the Paper Size Switch. Replace the Main Harness Assembly.
  • Code: 024-923 … 024-925
  • Description: (Y/ M/ C) Toner Cartridge Error: Life End Toner (Y/ M/ C/ K) error has occurred due to one of the following problems. • Printing cannot be continued during color printing because (Y/ M/ C) toner has run out. Or, color printing was specified when printing cannot be continued because (Y/ M/ C) toner has run out. • Toner K is Empty and any of the Toner YMC is also Empty. • 024-923: Operation Y Toner Empty • 024-924: Operation M Toner Empty • 024-925: Operation C Toner Empty
  • Causes: • Toner Cartridge (Y/ M/ C), PL 8.1.1 – PL 8.1.3
  • Troubleshooting Guides: 1. Replace the Toner Cartridge (Y/ M/ C)).
  • Code: 024-933, 024-940, 024-941
  • Description: (Y/ M/ C) Imaging Unit Cartridge Error: Life End Imaging Unit error has occurred due to one of the following problems. • During color printing, it was detected that printing cannot be continued because of (Y/ M/ C) Imaging Unit Life End. • Or, color printing was specified when printing cannot be continued because of (Y/ M/ C) Imaging Unit Life End. • 024-933: Operation Y Imaging Unit End of Life • 024-940: Operation M Imaging Unit End of Life • 024-941: Operation C Imaging Unit End of Life
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Replace the Imaging Unit (Y/ M/ C)).
  • Code: 024-946 … 024-949
  • Description: Tray (1/ 2/ 3/ 4) Out of Place The system detected that Tray 1/ 2/ 3/ 4 was not installed. • 024-946: Tray 1 Out Of Place • 024-947: Tray 2 Out Of Place • 024-948: Tray 3 Out Of Place • 024-949: Tray 4 Out Of Place
  • Causes: • Tray 1 Paper Size Switch, PL 2.1.6 • Tray Assembly 250, PL 2.1.11 • Tray Assembly 550, PL 15.1.1 • Tray 2/3/4 Paper Size Switch, PL 15.1.5
  • Troubleshooting Guides: 1. Reseat the Tray. If the Tray is seated properly, check the Paper Size Switch in DC330 Component Control. If it works, replace the Tray. If it doesn’t work, replace the Paper Size Switch. • Tray 1 Paper Size Switch • Tray 2/3/4 Paper Size Switch
  • Code: 024-950
  • Description: Tray 1 Error: Paper Empty The system detected that Tray 1 has no paper.
  • Causes: • No Paper Sensor 250, PL 2.2.2 • Feeder Harness Assembly, PL 2.2.3 • MCU PWB, PL 12.1.5 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the paper in the Tray. Is the paper in the Tray loaded correctly? Go to step 2. Load the paper. 2. Check the No Paper Sensor 250 operation. Perform DC330 Component Control [071-101] to check the operation of the No Paper Sensor 250. Is the Sensor working properly? Replace the MCU PWB. Go to step 3. 3. Check the connection between the No Paper Sensor 250 and MCU PWB. Are the connectors P/J4652A, P/J4651A, and P/J465A connected securely? Go to step 4. Connect the connectors P/J4652A, P/J4651A, and P/J465A. 4. Check the conductivity between the No Paper Sensor 250 and Relay Connector. Is the connection between P/J4652A <=> P/J4651A conducting properly? Go to step 5. Replace the Feeder Harness Assembly. 5. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4651A <=> P/J465A conducting properly? Go to step 6. Replace the Main Harness Assembly. 6. Check the voltage supply (+3.3VDC) to the No Paper Sensor 250. Measure the voltage between the MCU PWB GND <=> P/J465A-A1. Is there a voltage (approx. +3.3VDC) output? Replace the No Paper Sensor 250. Refer to +3.3VDC Power Troubleshooting.
  • Code: 024-951, 024-952, 024-953
  • Description: Tray 2/ 3/ 4 Error: Paper Empty The system detected that Tray 2/ 3/ 4 has no paper.
  • Causes: • MCU PWB, PL 12.1.5 • Option Harness Assembly, PL 12.3.5 • Feeder No Paper Sensor, PL 15.2.8 • Option No Paper Feed Harness Assembly, PL 15.2.9 • Option Feeder 1 Relay Harness Assembly, PL 15.2.30 • Option Rear Feeder Harness Assembly, PL 15.2.32 • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the paper in the Tray. Is the paper in the Tray loaded correctly? Go to step 2. Load the paper. 2. Check the Feeder No Paper Sensor operation. Perform DC330 Component Control to check the operation of the Feeder No Paper Sensor. • Tray 2 [071-122] • Tray 3 [071-123] • Tray 4 [071-124] Is the Sensor working properly? Replace the MCU PWB. Go to step 3. 3. Check the connection between the Feeder No Paper Sensor and Feeder PWB. Are the connectors P/J123, P/J612, and P/J421 connected securely? Go to step 4. Connect the connectors P/J123, P/J612, and P/J421. 4. Check the conductivity between Feeder No Paper Sensor and Relay Connector. Is the connection between P/J123 <=> P/J612 conducting properly? Go to step 5. Replace the Option No Paper Feed Harness Assembly. 5. Check the conductivity between the Relay Connector and Feeder PWB. Is the connection between P/J612 <=> P/J421 conducting properly? Go to step 6. Replace the Option Rear Feeder Harness Assembly. 6. Check the voltage supply (+3.3VDC) to the Feeder No Paper Sensor. Measure the voltage between the Feeder PWB GND <=> P/J421-3. Is there a voltage (approx. +3.3VDC) output? Replace the Feeder No Paper Sensor. Go to step 7. 7. Check the voltage supply (+3.3VDC) to the Feeder PWB. Measure the voltage between the Feeder PWB GND <=> P/J419-4. Is there a voltage (approx. +3.3VDC) output? Replace the Feeder PWB. Go to step 8. 8. Check the voltage output (+3.3VDC) from the MCU PWB. Measure the voltage between the MCU PWB GND <=> P/J461-7. Is there a voltage (approx. +3.3VDC) output? Go to step 9. Refer to +3.3VDC Power Troubleshooting. 9. Check the connection between the Feeder PWB and MCU PWB. Are the connectors P/J419, P/J4611, and P/J461 connected securely? Replace the following parts in sequence: • Option Feeder 1 Relay Harness Assembly • Option Harness Assembly Connect the connectors P/J419, P/J4611, and P/J461.
  • Code: 024-954
  • Description: Bypass Tray Error: Paper Empty The system detected that the Bypass Tray has no paper.
  • Causes: • Front Harness Assembly, PL 4.2.11 • Bypass Tray No Paper Sensor, PL 4.4.3 • MCU PWB, PL 12.1.5 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the Bypass Tray No Paper Sensor operation. Perform DC330 Component Control [071-100] to check the operation of the Bypass Tray No Paper Sensor. Is the Sensor working properly? Replace the MCU PWB. Go to step 2. 2. Check the connection of the Bypass Tray No Paper Sensor. Check the connection between the Bypass Tray No Paper Sensor and MCU PWB. Are the connectors P/J4752, P/J4751, and P/J475 connected securely? Go to Step 3 Connect the connectors P/J4752, P/J4751, and P/J475. 3. Check the conductivity between the Bypass Tray No Paper Sensor and Relay Connector. Is the connection between P/J4752 <=> P/J4751 conducting properly? Go to step 4. Replace the Front Harness Assembly. 4. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4751 <=> P/J475 conducting properly? Go to step 5. Replace the Main Harness Assembly. 5. Check the voltage supply (+3.3VDC) to the Bypass Tray No Paper Sensor. Measure the voltage between the MCU PWB GND <=> P/J475-1. Is there a voltage (approx. +3.3VDC) output? Replace the Bypass Tray No Paper Sensor). Refer to +3.3VDC Power Troubleshooting.
  • Code: 024-958
  • Description: Bypass Tray Size Mismatch The paper size in the Bypass Tray and the paper size specified for printing are different.
  • Causes:
  • Troubleshooting Guides: 1. Load the correct paper into the appropriate tray. 2. If the problem persists, go to Sensor Troubleshooting. 3. If the problem persists, go to Common Job Fail.
  • Code: 024-963
  • Description: (Y/ M/ C) Toner Cartridge Error: Life End Toner (Y/ M/ C/ K) error has occurred due to one of the following problems. • Printing cannot be continued during color printing because (Y/ M/ C) toner has run out. Or, color printing was specified when printing cannot be continued because (Y/ M/ C) toner has run out. • Toner K is Empty and any of the Toner YMC is also Empty. • 093-963: Plural Toner Empty
  • Causes: • Toner Cartridge (Y/ M/ C), PL 8.1.1 – PL 8.1.3
  • Troubleshooting Guides: 1. Replace the Toner Cartridge (Y/ M/ C)).
  • Code: 024-965
  • Description: ATS/ APS No Paper (IOTsc Detect) The paper specified for printing is not loaded in the Tray.
  • Causes:
  • Troubleshooting Guides: 1. Load the correct paper into the appropriate tray. 2. If the problem persists, go to Sensor Troubleshooting. 3. If the problem persists, go to Common Job Fail.
  • Code: 024-966
  • Description: ATS/ APS No Destination Error The paper specified for printing cannot be detected.
  • Causes:
  • Troubleshooting Guides: 1. Change the settings. 2. Replace the Tray. 3. If the problem persists, go to Sensor Troubleshooting. 4. If the problem persists, go to Common Job Fail.
  • Code: 024-985
  • Description: Bypass Tray Stop Check The Bypass Tray stopped running due to an obstruction.
  • Causes:
  • Troubleshooting Guides: 1. Check the paper size/ paper orientation/ paper type settings and press the Eject/Set key.
  • Code: 025-596, 025-597
  • Description: • 025-596: An NG occurred when HDD Fail Forecast of Diagnostics was executed. • 025-597: An error occurred when HDD initialization of Diagnostics was executed.
    HDD error has occurred due to one of the following problems. • A NG occurred when HDD Fail Forecast of Diagnostics was executed. • An error occurred when HDD initialization of Diagnostics was executed.
  • Causes: • HDD, PL 12.4.20
  • Troubleshooting Guides: 1. Reconnect the HDD wiring harness connectors. 2. If problem persists, replace the HDD Assembly).
  • Code: 041-310
  • Description: F/W Error IM software control error detected.
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the firmware version of the MCU PWB. Is it the latest MCU PWB firmware version? Replace the MCU PWB. Update firmware (Firmware Update).
  • Code: 041-318 … 041-322
  • Description: I/D Error I/D error has occurred due to one of the following problems. • The serial number is mismatched. • The XPC is mismatched. • The data is mismatched. • 041-318: IOT Serial Number Fail • 041-321: XPC Fail • 041-322: IOT Data Fail
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Replace the MCU PWB.
  • Code: 041-340
  • Description: IOT NV-RAM Error NVM (EEPROM) data error. (The specific values are not in their specified addresses.)
  • Causes: • MCU PWB, PL 12.1.15 • EEPROM PWB, PL 12.1.18
  • Troubleshooting Guides: 1. Check the connection of the EEPROM. Is the EEPROM connected to the MCU PWB properly? Go to step 2. Reinstall the EEPROM. 2. Replace the EEPROM PWB. Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 041-401
  • Description: 300K Kit Error The print volume (PV) of the Dispense Motor, Trickle Motor, or Registration Roller has reached the specified value (A4 LEF imp = 300 kPV) which indicates that the lifespan is approaching the end.
  • Causes: • Registration Roller (Registration Chute Assembly), PL 5.1.1 • Developer Housing Assemblies (C/ M/ Y/ K), PL 8.1.5 – PL 8.1.8 • Waste Auger Assembly (Trickle Guide), PL 8.1.10 • Dispense Motor Assembly, 8.1.15
  • Troubleshooting Guides: 1. Perform DC135 HFSI. 2. Reset the 300K Kit (Chain-Link 950-876).
  • Code: 042-323
  • Description: (K) Drum Motor Failure The change of the port status at the failure of the Drum Motor is always monitored.
  • Causes: • Imaging Unit (K), PL 6.1.4 • PR Harness Assembly (K), PL 11.1.23 • PR Drive Assembly Kit, PL 11.1.99 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation state of the Imaging Unit (K)). Is the Imaging Unit (K) installed properly, with no contamination at the contact points and in contact with the left and right guides? Go to step 2. Clean the contact points. Reinstall the Imaging Unit (K). 2. Check the Drum Motor (K) operation. Perform DC330 Component Control [071-005] to check the rotation of the Drum Motor (K). Is the Motor working properly? Replace the MCU PWB. Go to step 3. 3. Check the installation of the Drum Motor (K)). Manually rotate the Drum Motor (K). Does the Motor rotate? Reinstall the Drum Motor (K). Go to step 4. 4. Check the connections between the Drum Motor (K) and MCU PWB, as well as between the Drum Motor (K) and LVPS PWB. Are the connectors P/J472, P/J4723, P/J4724, P/J524, P/J5246, and P/J5243 connected securely? Go to step 5. Re-connect the connectors P/J472, P/J4723, P/J4724, P/J524, P/J5246, and P/J5243. 5. Check the conductivity between the Drum Motor (K) and Relay Connector. Are the connections between P/J4724 <=> P/J4723 and between P/J5243 <=> P/J5246 conducting properly? Go to step 6. Replace the PR Harness Assembly (K). 6. Check the conductivity between the Relay Connector and LVPS PWB. Is the connection between P/J5246 <=> P/J524 conducting properly? Go to step 7. Replace the Main Harness Assembly. 7. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4723 <=> P/J472 conducting properly? Go to step 8. Replace the Main Harness Assembly. 8. Check the voltage supply (+3.3VDC) to the Drum Motor (K). Measure the voltage between the MCU PWB GND <=> P/J472-16. Is there a voltage (approx. +3.3VDC) output? Go to step 9. Refer to +3.3VDC Power Troubleshooting. 9. Check the voltage supply (+24VDC) to the Drum Motor K. Measure the voltage between LVPS PWB GND <=> P/J524-5. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Drum Motor (K)). Replace the LVPS PWB.
  • Code: 042-329
  • Description: HVPS2 Fan Failure The HVPS2 Fan is having rotation error.
  • Causes: • HVPS2 Fan, PL 12.1.3 • MCU PWB, PL 12.1.15 • Top Harness Assembly, PL 12.2.4 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the HVPS2 Fan operation. Perform DC330 Component Control [042-005] to check the rotation of the HVPS2 Fan. Is the Fan working properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of the HVPS2 Fan. Manually rotate the HVPS2 Fan. Does the Fan rotate? Reinstall the HVPS2 Fan. Go to step3. 3. Check the connection between the HVPS2 Fan and MCU PWB. Are the connectors P/J468, P/J4681, and P/J4683A connected securely? Go to step 4. Connect the connectors P/J468, P/J4681, and P/J4683A. 4. Check the conductivity between the HVPS2 Fan and Relay Connector. Is the connection between P/J4683A <=> P/J4681 conducting properly? Go to step 5. Replace the Top Harness Assembly. 5. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4681 <=> P/J468 conducting properly? Replace the HVPS2 Fan. Replace the Top Harness Assembly.
  • Code: 042-335
  • Description: Developer Fan (Process Fan 1) Failure The Developer Fan (Process 1 Fan) is having rotation error.
  • Causes: • MCU PWB, PL 12.1.15 • Developer Fan, PL 12.2.16 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the Developer Fan operation. Perform DC330 Component Control [042-002] to check the operation of the Developer Fan. Is the Belt Retract Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of the Developer Fan. Manually rotate the Developer Fan. Does the Fan rotate? Reinstall the Developer Fan. Go to step 3. 3. Check the connection between the Developer Fan and MCU PWB. Are the connectors P/J465 and P/J4652B connected securely? Go to step 4. Connect the connectors P/J465 and P/J4652B. 4. Check the conductivity between the Developer Fan and MCU PWB. Is the connection between P/J4652B <=> P/J465 conducting properly? Replace the Developer Fan. Replace the Main Harness Assembly.
  • Code: 042-347
  • Description: (Y/ M/ C) Drum Motor Failure The port status changed when the Drum Motor has an error. This is always monitored.
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1 • Drum Motor (PR Drive Assembly) (Y/ M/ C), PL 11.1.2 • PR Harness Assembly (Y/ M/ C), PL 11.1.22 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Developer Fan, PL 12.2.16 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation state of the Imaging Unit (Y / M / C)). Is the Imaging Unit (Y / M / C) installed properly, with no contamination at the contact points and it is in contact with the left and right Guides? Go to step 2. Clean the contact points. Reinstall the Imaging Unit (Y / M / C). 2. Check the Drum Motor (Y / M / C) operation. Perform DC330 Component Control [071-001] to check the rotation of the Drum Motor (Y / M / C). Is the Drum working properly? Replace the MCU PWB. Go to step 3. 3. Check the installation of the Drum Motor (Y / M / C)). Manually rotate the Drum Motor (Y / M / C). Doe the Motor rotate? Reinstall the Drum Motor (Y / M / C). Go to step 4. 4. Check the connections between the Drum Motor (Y / M / C) and MCU PWB, as well as between the Drum Motor (Y / M / C) and LVPS PWB. Are the connectors P/J472, P/J4721, P/J4722, P/J524, P/J5245, and P/J5244 connected securely? Go to step 5. Connect the connectors P/J472, P/J4721, P/J4722, P/J524, P/J5245, and P/J5244. 5. Check the conductivity between the Drum Motor (Y / M / C) and Relay Connector. Are the connections between P/J4722 <=> P/J4721 and between P/J5244 <=> P/J5245 conducting properly? Go to step 6. Replace the PR Harness Assembly (Y/ M/ C). 6. Check the conductivity between the Relay Connector and LVPS PWB. Is the connection between P/J5245 <=> P/J524 conducting properly? Go to step 7. Replace the Main Harness Assembly. 7. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4721 <=> P/J472 conducting properly? Go to step 8. Replace the Main Harness Assembly. 8. Check the voltage supply (+3.3VDC) to the Drum Motor (Y / M / C). Measure the voltage between the MCU PWB GND <=> P/J472-8. Is there a voltage (approx. +3.3VDC) output? Go to step 9. Refer to +3.3VDC Power Troubleshooting. 9. Check the voltage supply (+24VDC) to the Drum Motor (Y / M / C). Measure the voltage between the LVPS PWB GND <=> P/J524-3. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Drum Motor (Y / M / C)). Replace the LVPS PWB.
  • Code: 042-398
  • Description: LVPS Fan Failure The LVPS Fan is not rotating up to the specified rotation count.
  • Causes: • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • LVPS Fan, PL 12.2.22 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the LVPS Fan operation. Perform DC330 Component Control [042-003] to check the operation of the LVPS Fan. Is the Belt Retract Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of the LVPS Fan. Manually rotate the LVPS Fan. Is the Fan working properly? Reinstall the LVPS Fan. Go to step 3. 3. Check the connection between the LVPS Fan and LVPS PWB. Are the connectors P/J523 and P/J5231 connected securely? Go to step 4. Connect the connectors P/J523 and P/J5231. 4. Check the connection between the LVPS PWB and MCU PWB. Are the connectors P/J527 and P/J451 connected securely? Go to step 5. Connect the connectors P/J527 and P/J451. 5. Check the conductivity between the LVPS Fan and LVPS PWB. Is the connection between P/J523 <=> P/J5231 conducting properly? Go to step 6. Replace the Main Harness Assembly. 6. Check the conductivity between the LVPS PWB and MCU PWB. Is the connection between P/J527 <=> P/J451 conducting properly? Go to step 7. Replace the Main Harness Assembly. 7. Check the voltage supply (+24VDC) to the LVPS Fan. Perform DC330 Component Control [042-003]. Measure the voltage between the LVPS PWB GND <=> P/J523-1. Is there a voltage (approx. +24VDC) output? Replace the LVPS Fan. Replace the LVPS PWB.
  • Code: 045-310, 045-311
  • Description: I/F Failure Start Image Marking Timeout Error Communication failure has occurred due to one of the following problems: • Image preparation failure of the Controller • Communication failure between the MCU and the Controller
  • Causes: • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Check the connection between the I/P PWB and MCU PWB. Are the connectors P/J471 and P/J470 connected securely? Go to step 2. Connect the connectors P/J471 and P/J470. 2. Check the conductivity between the I/P PWB and MCU PWB. Is the connection between P/J471 <=> P/J470 conducting properly? Replace the MCU PWB. Go to step 3. Replace the Main Harness Assembly. 3. Does the error persist? Replace the I/P PWB PWB). Troubleshooting complete.
  • Code: 060-310, 061-340, 061-346
  • Description: ROS Failure Laser error has occurred due to one of the following problems. • The SOS is unstable (rotation is uneven). • The laser is Off. • The ROS did not become READY due to any of the above. • When LD Alarm K occurs. If LD deterioration is detected, it becomes a Fail. • After the Polygon Motor has activated, it was not judged to have reached stable rotation even after the specified time has passed.
  • Causes: • ROS Assembly (Laser Unit), PL 7.1.1 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the connections between the Laser Unit and MCU PWB, as well as between the Laser Unit and LVPS PWB. Are the connectors P/J4691, P/J469, P/J5251, and P/J525 connected securely? Go to step 2. Connect the connector P/J4691, P/J469, P/J5251, and P/J525. 2. Check the conductivity of the Main Harness Assembly. Are the connections between P/J4691 <=> P/J469 and between P/J5251 <=> P/J525 conducting properly? Go to step 3. Replace the Main Harness Assembly. 3. Check the voltage supply (+5VDC) to the Laser Unit. Measure the voltage between the LVPS PWB GND <=> P/J525-1. Is there a voltage (approx. +5VDC) output? Close the Interlock Switch and check. Go to step 4. Replace the LVPS PWB 4. Check the voltage supply (+24VDC) to the Laser Unit. Measure the voltage between the MCU PWB GND <=> P/J469-3. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Go to step 5. Refer to +24VDC Power Troubleshooting. 5. Check the voltage supply (+3.3VDC) to the Laser Unit. Measure the voltage between the MCU PWB GND <=> P/J469-8. Is there a voltage (approx. +3.3VDC) output? Go to step 6. Refer to +3.3VDC Power Troubleshooting. 6. Replace the Laser Unit/ Front Spring Assembly/ Right Rear Spring Assembly/ Left Rear Spring Assembly). Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 071-101
  • Description: Tray 1 Miss Feed Jam/ Option Regi On Jam After a paper was fed from Tray 1, it did not reach the Registration Sensor.
  • Causes: • Turn Roller Assembly, PL 2.2.1 • Feed Roller Clutch, PL 2.2.8 • Tray 1 Feed Roller Kit, PL 2.2.99 • Registration Sensor, PL 5.1.3 • Bypass Tray Turn Roller, PL 5.1.8 • Turn Roller Clutch, PL 5.1.9 • Paper Handling Motor (P/H Drive Assembly), PL 11.1.19 • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Feeder PWB, PL 15.2.3
  • Troubleshooting Guides: 1. Check the installation of Tray 1. Is Tray 1 installed properly? Go to step 2. Reinstall Tray 1. 2. Check the paper transport path. Is there any debris found on the paper transport path? Remove the debris from the paper transport path. Go to step 3. 3. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 4. Reinstall the Feed Rollers. 4. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 5. 5. Check the Registration Sensor operation. Perform DC330 Component Control [071-102] to check the operation of the Registration Sensor. Is the Registration Sensor operating normally? Go to step 6. Go to Registration Sensor. 6. Check the Turn Roller Clutch operation. Perform DC330 Component Control [071-016] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 7. Go to Turn Roller Clutch. 7. Check the Feed Roller Clutch operation. Perform DC330 Component Control [071-015] to check the operation of the Feed Roller Clutch. Is the Feed Roller Clutch operating properly? Go to step 8. Go to Feed Roller Clutch. 8. Check the Paper Handling (P/H) Motor operation. Perform DC330 Component Control [071-009] to check the operation of the P/H Motor. Is the P/H Motor operating normally? • When the Optional Tray is not installed, replace the MCU PWB. • When the Optional Tray is installed, go to step 9. Go to Paper Handling Motor. 9. Check the Paper Jam Sensor operation (Tray 2). Perform DC330 Component Control [071-125] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Replace the MCU PWB. Go to Paper Jam Sensor.
  • Code: 072-101
  • Description: Tray 2 Miss Feed Jam After a paper was fed from Tray 2, it did not reach the Tray 2 Paper Jam Sensor.
  • Causes: • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Feed Roller Clutch, PL 15.2.13 • Turn Roller Assembly, PL 15.2.24 • Turn Roller Clutch, PL 15.2.25 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Feeder PWB, PL 15.2.33 • Option Tray 2/ 3/ 4 Feed Roller Kit, PL 15.2.99 • Retard Roller, PL 15.3.12
  • Troubleshooting Guides: 1. Check the installation of Tray 2. Is Tray 2 installed properly? Go to step 2. Reinstall Tray 2. 2. Check the paper transport path. Is there any debris found on the paper transport path? Remove the debris from the paper transport path. Go to step 3. 3. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 4. Reinstall the Feed Rollers. 4. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 5. 5. Check the Paper Jam Sensor operation (Tray 2). Perform DC330 Component Control [071-125] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Go to step 6. Go to Paper Jam Sensor. 6. Check the Turn Roller Clutch operation (Tray 2). Perform DC330 Component Control [071-029] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 7. Go to Turn Roller Clutch (Tray 2/ 3/ 4). 7. Check the Feed Roller Clutch operation (Tray 2). Perform DC330 Component Control [071-026] to check the operation of the Feed Roller Clutch. Is the Feed Roller Clutch operating properly? Go to step 8. Go to Feed Roller Clutch (Tray 2/ 3/ 4). 8. Check the Feeder Motor operation (Tray 2). Perform DC330 Component Control [071-018] to check the operation of the Feeder Motor. Is the Feeder Motor operating normally? Replace the MCU PWB. Go to Option Feeder Mode Error.
  • Code: 072-103
  • Description: Path 2 Sensor On Jam After the Tray 3 Paper Jam Sensor has detected a paper, the paper did not reach the Tray 2 Paper Jam Sensor.
  • Causes: • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Turn Roller Assembly, PL 15.2.24 • Turn Roller Clutch, PL 15.2.25 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Feeder PWB, PL 15.2.33 • Option Tray 2/ 3/ 4 Feed Roller Kit, PL 15.2.99
  • Troubleshooting Guides: 1. Check the paper transport path. Is there any debris on the paper transport path? Remove the debris from the paper transport path. Go to step 2. 2. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 3. Reinstall the Feed Rollers. 3. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 4. 4. Check the Paper Jam Sensor operation (Tray 2). Perform DC330 Component Control [071-125] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Go to step 5. Go to Paper Jam Sensor. 5. Check the Turn Roller Clutch operation (Tray 2). Perform DC330 Component Control [071-029] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 6. Go to Turn Roller Clutch (Tray 2/ 3/ 4). 6. Check the Feeder Motor operation (Tray 2). Perform DC330 Component Control [071-018] to check the operation of the Feeder Motor. Is the Feeder Motor operating normally? Go to step 7. Go to Option Feeder Mode Error. 7. Check the Paper Jam Sensor operation (Tray 3). Perform DC330 Component Control [071-126] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Replace the MCU PWB. Go to Paper Jam Sensor.
  • Code: 072-310
  • Description: Tray 2 Motor Fail Option Feeder 2 Motor error.
  • Causes: • MCU PWB, PL 12.1.15 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Option Left Feeder Harness Assembly, PL 15.2.31 • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Feeder Motor operation. Perform DC330 Component Control to check the operation of the Feeder Motor: • Tray 2 [071-018] • Tray 3 [071-020] • Tray 4 [071-022] Is the Feeder Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of Feeder Motor. Manually rotate the Feeder Motor. Does the Motor rotate? Reinstall the Feeder Motor. Go to step 3. 3. Check the connection between the Feeder Motor and Feeder PWB. Are the connectors P/J422, P/J221, and P/J222 connected securely? Go to step 4. Connect the connectors P/J422, P/J221, and P/J222. 4. Check the conductivity between Feeder Motor and Feeder PWB. Are the connections between P/J221 <=> P/J422 and P/J222 <=> P/J422 conducting properly? Go to step 5. Replace the Option Left Feeder Harness Assembly. 5. Check the voltage supply (+24VDC) to the Feeder Motor. Measure the voltage between the Feeder PWB GND <=> P/J422-6. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Option Drive Assembly. Replace the Feeder PWB.
  • Code: 072-312
  • Description: Tray 2 Mode Fail Tray 2 DL mode has activated.
  • Causes: • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Tray where the problem has occurred. 2. Check the firmware version of the Feeder PWB. Is it the latest Feeder PWB firmware version? If Feeder PWB firmware version is not available, replace the Feeder PWB. Replace the Feeder PWB. Update the firmware version of the Feeder PWB.
  • Code: 073-101
  • Description: Tray 3 Miss Feed Jam After a paper was fed from Tray 3, it did not reach the Tray 3 Paper Jam Sensor.
  • Causes: • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Feed Roller Clutch, PL 15.2.13 • Turn Roller Assembly, PL 15.2.24 • Turn Roller Clutch, PL 15.2.25 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Feeder PWB, PL 15.2.33 • Option Tray 2/ 3/ 4 Feed Roller Kit, PL 15.2.99
  • Troubleshooting Guides: 1. Check the installation of Tray 3. Is Tray 3 installed properly? Go to step 2. Reinstall Tray 3. 2. Check the paper transport path. Is there any debris on the paper transport path? Remove the debris from the paper transport path. Go to step 3. 3. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 4. Reinstall the Feed Rollers. 4. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 5. 5. Check the Paper Jam Sensor operation (Tray 3). Perform DC330 Component Control [071-126] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Go to step 6. Go to Paper Jam Sensor. 6. Check the Turn Roller Clutch operation (Tray 3). Perform DC330 Component Control [071-030] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 7. Go to Turn Roller Clutch (Tray 2/ 3/ 4). 7. Check the Feed Roller Clutch operation (Tray 3). Perform DC330 Component Control [071-027] to check the operation of the Feed Roller Clutch. Is the Feed Roller Clutch operating properly? Go to step 8. Go to Feed Roller Clutch (Tray 2/ 3/ 4). 8. Check the Feeder Motor operation (Tray 3). Perform DC330 Component Control [071-020] to check the operation of the Feeder Motor. Is the Feeder Motor operating normally? Replace the MCU PWB. Go to Option Feeder Mode Error.
  • Code: 073-103
  • Description: Path 3 Sensor On Jam After the Tray 4 Paper Jam Sensor has detected a paper, the paper did not reach the Tray 3 Paper Jam Sensor.
  • Causes: • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Turn Roller Assembly, PL 15.2.24 • Turn Roller Clutch, PL 15.2.25 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Feeder PWB, PL 15.2.33 • Option Tray 2/ 3/ 4 Feed Roller Kit, PL 15.2.99
  • Troubleshooting Guides: 1. Check the paper transport path. Is there any debris on the paper transport path? Remove the debris from the paper transport path. Go to step 2. 2. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 3. Reinstall the Feed Rollers. 3. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 4. 4. Check the Paper Jam Sensor operation (Tray 3). Perform DC330 Component Control [071-126] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Go to step 5. Go to Paper Jam Sensor. 5. Check the Turn Roller Clutch operation (Tray 3). Perform DC330 Component Control [071-030] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 6. Go to Turn Roller Clutch (Tray 2/ 3/ 4). 6. Check the Feeder Motor operation (Tray 3). Perform DC330 Component Control [071-020] to check the operation of the Feeder Motor. Is the Feeder Motor operating normally? Go to step 7. Go to Option Feeder Mode Error. 7. Check the Paper Jam Sensor operation (Tray 4). Perform DC330 Component Control [071-127] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Replace the MCU PWB. Go to Paper Jam Sensor.
  • Code: 073-310
  • Description: Tray 3 Motor Fail Option Feeder 3 Motor error.
  • Causes: • MCU PWB, PL 12.1.15 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Option Left Feeder Harness Assembly, PL 15.2.31 • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Feeder Motor operation. Perform DC330 Component Control to check the operation of the Feeder Motor: • Tray 2 [071-018] • Tray 3 [071-020] • Tray 4 [071-022] Is the Feeder Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of Feeder Motor. Manually rotate the Feeder Motor. Does the Motor rotate? Reinstall the Feeder Motor. Go to step 3. 3. Check the connection between the Feeder Motor and Feeder PWB. Are the connectors P/J422, P/J221, and P/J222 connected securely? Go to step 4. Connect the connectors P/J422, P/J221, and P/J222. 4. Check the conductivity between Feeder Motor and Feeder PWB. Are the connections between P/J221 <=> P/J422 and P/J222 <=> P/J422 conducting properly? Go to step 5. Replace the Option Left Feeder Harness Assembly. 5. Check the voltage supply (+24VDC) to the Feeder Motor. Measure the voltage between the Feeder PWB GND <=> P/J422-6. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Option Drive Assembly. Replace the Feeder PWB.
  • Code: 073-311
  • Description: Tray 3 Mode Fail Tray 3 DL mode has activated.
  • Causes: • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Tray where the problem has occurred. 2. Check the firmware version of the Feeder PWB. Is it the latest Feeder PWB firmware version? If Feeder PWB firmware version is not available, replace the Feeder PWB. Replace the Feeder PWB. Update the firmware version of the Feeder PWB.
  • Code: 074-101
  • Description: Tray 4 Miss Feed Jam After a paper was fed from Tray 4, it did not reach the Tray 4 Paper Jam Sensor.
  • Causes: • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Feed Roller Clutch, PL 15.2.13 • Turn Roller Assembly, PL 15.2.24 • Turn Roller Clutch, PL 15.2.25 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Feeder PWB, PL 15.2.33 • Option Tray 2/ 3/ 4 Feed Roller Kit, PL 15.2.99
  • Troubleshooting Guides: 1. Check the installation of Tray 4. Is Tray 4 installed properly? Go to step 2. Reinstall Tray 4. 2. Check the paper transport path. Is there any debris on the paper transport path? Remove the debris from the paper path transport. Go to step 3. 3. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 4. Reinstall the Feed Rollers. 4. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 5. 5. Check the Paper Jam Sensor operation Perform DC330 Component Control [071-127] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating properly? Go to step 6. Go to Paper Jam Sensor. 6. Check the Turn Roller Clutch operation (Tray 4) Perform DC330 Component Control [071-031] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 7. Go to Turn Roller Clutch (Tray 2/ 3/ 4). 7. Check the Feed Roller Clutch operation (Tray 4) Perform DC330 Component Control [071-028] to check the operation of the Feed Roller Clutch. Is the Feed Roller Clutch operating properly? Go to step 8. Go to Feed Roller Clutch (Tray 2/ 3/ 4). 8. Check the Feeder Motor operation (Tray 4) Perform DC330 Component Control [071-022] to check the operation of the Feeder Motor. Is the Feeder Motor operating normally? Replace the MCU PWB. Go to Option Feeder Mode Error.
  • Code: 074-310
  • Description: Tray 4 Motor Fail Option Feeder 4 Motor error.
  • Causes: • MCU PWB, PL 12.1.15 • Feeder Motor (Option Drive Assembly), PL 15.2.28 • Option Left Feeder Harness Assembly, PL 15.2.31 • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Feeder Motor operation. Perform DC330 Component Control to check the operation of the Feeder Motor: • Tray 2 [071-018] • Tray 3 [071-020] • Tray 4 [071-022] Is the Feeder Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of Feeder Motor. Manually rotate the Feeder Motor. Does the Motor rotate? Reinstall the Feeder Motor. Go to step 3. 3. Check the connection between the Feeder Motor and Feeder PWB. Are the connectors P/J422, P/J221, and P/J222 connected securely? Go to step 4. Connect the connectors P/J422, P/J221, and P/J222. 4. Check the conductivity between Feeder Motor and Feeder PWB. Are the connections between P/J221 <=> P/J422 and P/J222 <=> P/J422 conducting properly? Go to step 5. Replace the Option Left Feeder Harness Assembly. 5. Check the voltage supply (+24VDC) to the Feeder Motor. Measure the voltage between the Feeder PWB GND <=> P/J422-6. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Option Drive Assembly. Replace the Feeder PWB.
  • Code: 074-311
  • Description: Tray 4 Mode Fail Tray 4 DL mode has activated.
  • Causes: • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Tray where the problem has occurred. 2. Check the firmware version of the Feeder PWB. Is it the latest Feeder PWB firmware version? If Feeder PWB firmware version is not available, replace the Feeder PWB. Replace the Feeder PWB. Update the firmware version of the Feeder PWB.
  • Code: 075-100
  • Description: Bypass Tray Miss Feed Jam After a paper was fed from the Bypass Tray, it did not reach the Registration Sensor.
  • Causes: • Retard Roller (Separator Retard Holder Assembly), PL 3.1.8 • Bypass Tray Feed Solenoid, PL 4.3.10 • Bypass Tray Feed Roller Assembly, PL 4.4.14 • Registration Sensor, PL 5.1.3 • Bypass Tray Turn Roller, PL 5.1.8 • Turn Clutch Assembly, PL 5.1.9 • Paper Handling Motor (P/H Drive Assembly), PL 11.1.19 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the paper transport path. Is there any debris on the paper transport path? Remove the debris from the paper transport path. Go to step 2. 2. Check the installation of the Feed Roller. Is the Feed Roller installed properly? Go to step 3. Reinstall the Feed Roller. 3. Check the Feed Roller. Is the Feed Roller deformed or worn out? Replace the Feed Roller. Go to step 4. 4. Check the Registration Sensor operation. Perform DC330 Component Control [071-102] to check the operation of the Registration Sensor. Is the Registration Sensor operating normally? Go to step 5. Go to Registration Sensor. 5. Check the Turn Roller Clutch operation Perform DC330 Component Control [071-016] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 6. Go to Turn Roller Clutch. 6. Check the Paper Handling (P/H) Motor operation Perform DC330 Component Control [071-009] to check the operation of the P/H Motor. Is the P/H Motor operating normally? Go to step 7. Go to Paper Handling Motor. 7. Check the Bypass Tray Feed Solenoid operation. Perform DC330 Component Control [071-014] to check the operation of the Bypass Tray Feed Solenoid. Is the Bypass Tray Feed Solenoid operating normally? Replace the MCU PWB. Go to Bypass Tray Feed Solenoid.
  • Code: 077-101, 077-119
  • Description: Regi Off Jam/ Exit On Jam/ Duplex Exit In Jam Jam error has occurred due to one of the following problems. • After the Registration Sensor has detected a paper, it continues to detect the paper even after the specified time had passed. • Although the image formation is performed first, when the paper that had been delayed so as not to cause misfeeding has finally arrived, the image got truncated and results in this Jam.
  • Causes: • Fuser Motor (Fuser Drive Assembly), PL 4.2.16 • 2nd BTR (Transfer Roller), PL 4.3.18 • Registration Sensor, PL 5.1.3 • Registration Roller (Registration Chute Assembly), PL 5.1.1 • Registration Clutch, PL 5.1.11 • Exit Roller (Fuser Unit), PL 10.1.1 • Fuser Exit Sensor (Fuser Unit), PL 10.1.1 • Paper Handling Motor (P/H Drive Assembly), PL 11.1.19 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the paper transport path Is there any debris on the paper transport path? Remove the debris. Go to step 2. 2. Check the installation of the Registration Roller (Registration Chute). Is the Registration Chute installed properly? Go to step 3. Reinstall the Registration Chute. 3. Check the Registration Roller (Registration Chute). Is the Registration Chute damaged? Replace the Registration Chute. Go to step 4. 4. Check the Registration Sensor operation. Perform DC330 Component Control [071-102] to check the operation of the Registration Sensor. Is the Registration Sensor operating properly? Go to step 5. Go to Sensor Troubleshooting. 5. Check the Registration Clutch operation. Perform DC330 Component Control [071-013] to check the operation of the Registration Clutch. Is the Registration Clutch operating properly? Go to step 6. Go to Registration Clutch. 6. Check the Paper Handling (P/H) Motor operation. Perform DC330 Component Control [071-009] to check the operation of the P/H Motor. Is the P/H Motor operating properly? Go to step 7. Go to Paper Handling Motor. 7. Check the Fuser Exit Sensor operation. Perform DC330 Component Control [071-104] to check the operation of the Fuser Exit Sensor. Is the Fuser Exit Sensor operating properly? Go to step 8. Go to Fuser Exit Sensor. 8. Check the Fuser Motor operation. Perform DC330 Component Control [010-001] to check the operation of the Fuser Motor. Is the Fuser Motor operating properly? Replace the MCU PWB. Go to Fuser Motor.
  • Code: 077-117
  • Description: Option Registration On Jam After the Tray 2 Paper Jam Sensor has detected a paper, the paper did not reach the Registration Sensor.
  • Causes: • Turn Roller Assembly, PL 2.2.1 • Feed Roller Clutch, PL 2.2.8 • Nudger Roller/ Feed Roller, PL 2.2.11 • Retard Roller/ Feed Roller, PL 2.3.12 • Registration Sensor, PL 5.1.3 • Bypass Tray Turn Roller, PL 5.1.8 • Turn Roller Clutch, PL 5.1.9 • Paper Handling Motor (P/H Drive Assembly), PL 11.1.19 • MCU PWB, PL 12.1.15 • Paper Jam Sensor, PL 15.2.3 • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the installation of Tray 1. Is Tray 1 installed properly? Go to step 2. Reinstall Tray 1. 2. Check the paper transport path. Is there any debris found on the paper transport path? Remove the debris from the paper transport path. Go to step 3. 3. Check the installation of the Feed Rollers. Are the Feed Rollers installed properly? Go to step 4. Reinstall the Feed Rollers. 4. Check the Feed Rollers. Are the Feed Rollers deformed or worn out? Replace the Feed Rollers. Go to step 5. 5. Check the Registration Sensor operation. Perform DC330 Component Control [071-102] to check the operation of the Registration Sensor. Is the Registration Sensor operating normally? Go to step 6. Go to Registration Sensor. 6. Check the Turn Roller Clutch operation. Perform DC330 Component Control [071-016] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 7. Go to Turn Roller Clutch. 7. Check the Feed Roller Clutch operation. Perform DC330 Component Control [071-015] to check the operation of the Feed Roller Clutch. Is the Feed Roller Clutch operating properly? Go to step 8. Go to Feed Roller Clutch. 8. Check the Paper Handling (P/H) Motor operation. Perform DC330 Component Control [071-009] to check the operation of the P/H Motor. Is the P/H Motor operating normally? • When the Optional Tray is not installed, replace the MCU PWB. • When the Optional Tray is installed, go to step 9. Go to Paper Handling Motor. 9. Check the Paper Jam Sensor operation (Tray 2). Perform DC330 Component Control [071-125] to check the operation of the Paper Jam Sensor. Is the Paper Jam Sensor operating normally? Replace the MCU PWB. Go to Paper Jam Sensor.
  • Code: 077-123, 077-131
  • Description: Duplex Regi On Jam/ Duplex Sensor On Jam Duplex error has occurred due to one of the following problems. • After the Duplex Jam Sensor has detected a paper, the paper did not reach the Registration Sensor within the specified time. • After a paper has entered the Duplex Feed operation, it did not reach the Duplex Jam Sensor. • 077-123: Duplex Feed Regi Sensor On Jam • 077-131: Duplex Wait Sensor On Check Jam
  • Causes: • Registration Sensor, PL 5.1.3 • Bypass Tray Turn Roller, PL 5.1.8 • Turn Roller Clutch, PL 5.1.9 • Paper Handling Motor (P/H Drive Assembly), PL 11.1.19 • MCU PWB, PL 12.1.15 • Duplex Unit, PL 14.1.1 • Duplex Motor, PL 14.2.1 • Duplex Roller, PL 14.2.9 • Duplex In Clutch Assembly, PL 14.2.20 • Duplex PWB, PL 14.3.8 • Duplex Jam Sensor, PL 14.3.17
  • Troubleshooting Guides: 1. Check the paper transport path. Is there any debris on the paper transport path? Remove the debris. Go to step 2. 2. Check the Duplex Rollers. Are the Duplex Rollers installed properly? Go to step 3. Reinstall the Duplex Rollers. 3. Check the Duplex Rollers. Are the Duplex Rollers deformed or worn out? Replace the Duplex Unit. Go to step 4. 4. Check the Registration Sensor operation. Perform DC330 Component Control [071-102] to check the operation of the Registration Sensor. Is the Registration Sensor operating properly? Go to step 5. Go to Registration Sensor. 5. Check the Turn Roller Clutch operation. Perform DC330 Component Control [071-016] to check the operation of the Turn Roller Clutch. Is the Turn Roller Clutch operating properly? Go to step 6. Go to Turn Roller Clutch. 6. Check the Paper Handling (P/H) Motor operation. Perform DC330 Component Control [071-009] to check the operation of the P/H Motor. Is the P/H Motor operating properly? Go to step 7. Go to Paper Handling Motor. 7. Check the Duplex Jam Sensor operation. Perform DC330 Component Control [071-128] to check the operation of the Duplex Jam Sensor. Is the Duplex Jam Sensor operating properly? Go to step 8. Go to Duplex Jam Sensor. 8. Check the Duplex Clutch operation. Perform DC330 Component Control [010-017] to check the operation of the Duplex Clutch. Is the Duplex Clutch operating properly? Go to step 9. Go to Duplex Clutch. 9. Check the Duplex Motor operation. Perform DC330 Component Control [071-024] to check the operation of the Duplex Motor. Is the Duplex Motor operating normally? Replace the MCU PWB. Go to Duplex Motor.
  • Code: 077-300
  • Description: Cover Open: Front Cover or Top Cover Open The Front Cover Interlock was opened.
  • Causes: • MCU PWB, PL 12.1.15 • Interlock Cap Switch Kit, PL 12.2.4
  • Troubleshooting Guides: 1. Check the Front Cover Switch operation. Perform DC330 Component Control [041-303] to check the operation of the Front Cover Switch. Is the Front Cover Switch working properly? Go to step 2. Go to Front Cover Switch (Interlock Cap Switch). 2. Check the Front Cover Interlock Switch operation. Perform DC330 Component Control [041-300] to check the operation of the Front Cover Switch. Is the Front Cover Switch working properly? Replace the MCU PWB. Go to Front Cover Interlock Switch.
  • Code: 077-322
  • Description: Option I/F Failure: Feeder Detected Communication error between the IOT and the Tray, or between the IOT and the Duplex Unit.
  • Causes: • Duplex Harness Assembly, PL 4.2.18 • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1 • Option Harness Assembly, PL 12.3.5 • Duplex PWB, PL 14.3.8 • Duplex Relay Harness Assembly, PL 14.3.19 • Option Feeder 1 Relay Harness Assembly, PL 15.2.30 • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Turn Off the printer. Remove the Duplex Unit. Power On the printer. Does the error persist? Go to step 2. Go to step 6. 2. Check the connection between the Feeder PWB and MCU PWB. Are the connectors P/J419, P/J4611, and P/J461 connected securely? Go to step 3. Connect the connectors P/J419, P/J4611, and P/J461. 3. Check the conductivity between the Feeder PWB and Relay Connector. Is the connection between P/J419 <=> P/J4611 conducting properly? Go to step 4. Replace the Option Feeder 1 Relay Harness Assembly. 4. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4611 <=> P/J461 conducting properly? Go to step 5. Replace the Option Harness Assembly. 5. Replace the Feeder PWB. Does the error persist? Go to step 6. Troubleshooting complete. 6. Check the connection between the Duplex PWB and MCU PWB. Are the connectors P/J428, P/J4672, P/J4671, and P/J467 connected securely? Go to step 7. Connect the connectors P/J428, P/J4672, P/J4671, and P/J467. 7. Check the conductivity between the Duplex PWB and Relay Connector. Is the connection between P/J428 <=> P/J4672 conducting properly? Go to step 8. Replace the Duplex Relay Harness Assembly. 8. Check the conductivity between the Relay Connector and Relay Connector. Is the connection between P/J4672 <=> P/J4671 conducting properly? Go to step 9. Replace the Duplex Harness Assembly. 9. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4671 <=> P/J467 conducting properly? Go to step 10. Replace the Main Harness Assembly. 10. Replace the Duplex PWB. Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 077-323
  • Description: Paper Handling (P/H) Motor Failure The Paper Handling Motor rotation error is detected.
  • Causes: • Paper Handling Motor (P/H Drive Assembly), PL 11.1.19 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Main Harness Assembly, PL 12.3.1 • Paper Handling Motor Harness Assembly, PL 12.3.9
  • Troubleshooting Guides: 1. Check the Paper Handling (P/H) Motor operation. Perform DC330 Component Control [010-009] to check the operation of the P/H Motor. Is the P/H Motor operating properly? Replace the MCU PWB. Go to step 2. 2. Check the installation of the P/H Motor. Manually rotate the P/H Motor. Does the Motor rotate? Reinstall the P/H Motor. Go to step 3. 3. Check the connections between the P/H Motor and the MCU PWB, as well as between the P/H Motor and the LVPS PWB. Are the connectors P/J471, P/J4711, P/J524, P/J5247, and P/J5242 connected securely? Go to step 4. Connect the connectors P/J471, P/J4711, P/J524, P/J5247, and P/J5242. 4. Check the conductivity between the P/H Motor and Relay Connector. Is the connection between P/J5242 <=> P/J5247 conducting properly? Go to step 5. Replace the Paper Handling Motor Harness Assembly. 5. Check the conductivity between the P/H Motor and MCU PWB. Is the connection between P/J4711 <=> P/J472 conducting properly? Go to step 6. Replace the Paper Handling Motor Harness Assembly. 6. Check the conductivity between the Relay Connector and LVPS PWB. Is the connection between P/J5246 <=> P/J524 conducting properly? Go to step 7. Replace the Main Harness Assembly. 7. Check the voltage supply (+3.3VDC) to the P/H Motor. Measure the voltage between the MCU PWB GND <=> P/J471-16. Is there a voltage (approx. +3.3VDC) output? Go to step 8. Go to +3.3VDC Power Troubleshooting. 8. Check the voltage supply (+24VDC) to the P/H Motor. Measure the voltage between the LVPS PWB GND <=> P/J524-7. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the Paper Handling Motor. Replace the LVPS PWB.
  • Code: 077-328
  • Description: Option Feeder Mode Fail The Option Feeder error has occurred.
  • Causes: • Feeder PWB, PL 15.2.33
  • Troubleshooting Guides: 1. Check the Tray where the problem has occurred. 2. Check the firmware version of the Feeder PWB. Is it the latest Feeder PWB firmware version? If Feeder PWB firmware version is not available, replace the Feeder PWB. Replace the Feeder PWB. Update the firmware version of the Feeder PWB.
  • Code: 091-312
  • Description: HVPS Error CC HVPS failure.
  • Causes: • HVPS2 PWB, PL 12.1.2 • MCU PWB, PL 12.1.15 • HVPS1 PWB, PL 12.2.15 • Top Harness Assembly, PL 12.2.24 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the connection between the HVPS2 PWB and MCU PWB. Are the connectors P/J468, P/J4681, and P/J552 connected securely? Go to step 2. Connect the connectors P/J468, P/J4681, and P/J552. 2. Check the conductivity between the HVPS2 PWB and Relay Connector. Is the connection between P/J552 <=> P/J4681 conducting properly? Go to step 3. Replace the Top Harness Assembly. 3. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4681 <=> P/J468 conducting properly? Go to step 4. Replace the Main Harness Assembly. 4. Check the connection between the HVPS1 PWB and MCU PWB. Are the connectors P/J477 and P/J551 connected securely? Go to step 5. Connect the connectors P/J477 and P/J551. 5. Check the conductivity between the HVPS1 PWB and MCU PWB. Is the connection between P/J551 <=> P/J477 conducting properly? Go to step 6. Replace the Main Harness Assembly. 6. Check the voltage supply (+24VDC) to the HVPS2 PWB. Measure the voltage between the MCU PWB GND <=> P/J468B-B10. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Go to step 7. Go to +24VDC Power Troubleshooting. 7. Check the voltage supply (+24VDC) to the HVPS1 PWB. Measure the voltage between the MCU PWB GND <=> P/J477-9. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the HVPS2 PWB. Go to step 8. Go to +24VDC Power Troubleshooting. 8. Does the error persist? Replace the HVPS1 PWB. Go to step 9. Troubleshooting complete. 9. Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 091-402, 091-913
  • Description: (K) Imaging Unit Error: Life End Imaging Unit error has occurred due to one of the following problems. • Indicates that it is time to replace the Imaging Unit. • The Imaging Unit life end is detected. • 091-402: Imaging Unit Quality Life End • 091-913: Imaging Unit K End Of Life
  • Causes: • Imaging Unit (K), PL 6.1.4
  • Troubleshooting Guides: 1. Replace the Imaging Unit (K)).
  • Code: 091-407
  • Description: (K) Imaging Unit ID Error Imaging Unit error has occurred due to one of the following problems: • Imaging Unit K CRUM Comm Fail • Imaging Unit K CRUM Data Broken • Imaging Unit K CRUM Data Mismatch
  • Causes: • Imaging Unit (K), PL 6.1.4
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit (K)). Is there an Imaging Unit other than for (K) color installed? Or, is there an Imaging Unit for other than this printer installed? Replace the Imaging Unit (K)). Reinstall the Imaging Unit (K).
  • Code: 091-417, 091-924
  • Description: (Y) Imaging Unit ID Error Imaging Unit error has occurred due to one of the following problems. • Imaging Unit Y CRUM Comm Fail • Imaging Unit Y CRUM Data Broken • Imaging Unit Y CRUM Data Mismatch • Incorrect data in the Imaging Unit Y CRUM recognition area. • 091-417: Imaging Unit Y CRUM Trouble Info • 091-924: Imaging Unit Y CRUM Data Mismatch
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit. (Y)). Is there an Imaging Unit other than for (Y) color installed? Or, is there an Imaging Unit for other than this printer installed? Replace the Imaging Unit (Y)). Reinstall the Imaging Unit (Y).
  • Code: 091-427, 091-925
  • Description: (M) Imaging Unit ID Error Imaging Unit error has occurred due to one of the following problems. • Imaging Unit M CRUM Comm Fail • Imaging Unit M CRUM Data Broken • Imaging Unit M CRUM Data Mismatch • Incorrect data in the Imaging Unit M CRUM recognition area. • 091-427: Imaging Unit M CRUM Trouble Info • 091-925: Imaging Unit M CRUM Data Mismatch
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit (M)). Is there an Imaging Unit other than for (M) color installed? Or, is there an Imaging Unit for other than this printer installed? Replace the Imaging Unit (M)). Reinstall the Imaging Unit (M).
  • Code: 091-437, 091-926
  • Description: (C) Imaging Unit ID Error Imaging Unit error has occurred due to one of the following problems. • Imaging Unit C CRUM Comm Fail • Imaging Unit C CRUM Data Broken • Imaging Unit C CRUM Data Mismatch • Incorrect data in the Imaging Unit C CRUM recognition area. • 091-437: Imaging Unit C CRUM Trouble Info • 091-926: Imaging Unit C CRUM Data Mismatch
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit (C)). Is there an Imaging Unit other than for (C) color installed? Or, is there an Imaging Unit for other than this printer installed? Replace the Imaging Unit (C)). Reinstall the Imaging Unit (C).
  • Code: 091-480, 091-481, 091-482
  • Description: (Y/ M/ C) Imaging Unit Error: Life End The (Y/ M/ C) Imaging Unit Life End error has occurred due to one of the following problems. • Imaging Unit (Y/ M/ C) Quality End of Life • The Imaging Unit life end is detected. • 091-480: Imaging Unit Y Quality End of Life • 091-481: Imaging Unit M Quality End of Life • 091-482: Imaging Unit C Quality End of Life
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Replace the Imaging Unit (Y/ M/ C)).
  • Code: 091-911
  • Description: Belt CLN Waste Error: Life End After the Waste Toner Full Sensor has turned On, the PV or the pixel count exceeded the defined value.
  • Causes: • Waste Cartridge (Waste Toner Cartridge Assembly), PL 9.1.1 • Waste Cartridge Guide Assembly, PL 9.1.4 • Waste Cartridge Full Sensor, PL 9.1.5 • IBT Unit Kit, PL 9.1.99 • MCU PWB, PL 12.1.15 • Top Harness Assembly, PL 12.2.24 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the amount of waste toner in the Waste Cartridge. Is the Waste Cartridge fulled? Replace the Waste Cartridge. Go to step 2. 2. Check the Waste Cartridge Full Sensor for contamination and debris. Is there any contamination or debris on the Waste Cartridge Full Sensor? Clean the Waste Cartridge Full Sensor. Go to step 3. 3. Check the Waste Cartridge Full Sensor operation. Perform DC330 Component Control [093-209] to check the operation of the Waste Cartridge Full Sensor. Is the Waste Cartridge Full Sensor working properly? Replace the MCU PWB. Go to step 4. 4. Check the installation of Waste Cartridge Full Sensor. Is the Waste Cartridge Full Sensor installed properly? Go to step 5. Reinstall the Waste Cartridge Full Sensor. 5. Check the connection between the Waste Cartridge Full Sensor and MCU PWB. Are the connectors P/J4686, P/J4685, P/J4681A, and P/J468A connected securely? Go to step 6. Connect the connectors P/J4686, P/J4685, P/J4681A, and P/J468A. 6. Check the conductivity between the Waste Cartridge Full Sensor and Relay Connector. Is the connection between P/J4686 <=> P/J4685 conducting properly? Go to step 7. Replace the IBT Unit. 7. Check the conductivity between the Relay Connector and Relay Connector. Is the connection between P/J4685 <=> P/J4681A conducting properly? Go to step 8. Replace the Top Harness Assembly. 8. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4681A <=> P/J468A conducting properly? Go to step 9. Replace the Main Harness Assembly. 9. Check the voltage supply (+5VDC) to the Waste Cartridge Full Sensor. Measure the voltage between the MCU PWB GND <=> J468A-A10. Is there a voltage (approx. +5VDC) output? Replace the IBT Unit. Go to +5VDC Power Troubleshooting.
  • Code: 091-914, 091-915
  • Description: (K) Imaging Unit Error: Error Imaging Unit error has occurred due to one of the following problems. • Communication error of the CRUM for the Imaging Unit. • CRUM failure for Imaging Unit K • 091-914: Imaging Unit (K) CRUM Communication Fail • 091-915: Imaging Unit (K) CRUM Data Broken Fail
  • Causes: • Imaging Unit (K), PL 6.1.4 • Imaging Unit CRUM Connector Assembly, PL 6.1.6 • CRUM X Harness Assembly (K), PL 6.1.14 • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit (K)). Is the Imaging Unit (K) installed properly, with no debris at the contact point between the Imaging Unit CRUM Connector Assembly and CRUM PWB in the Imaging Unit (K)? Go to step 2. Reinstall the Imaging Unit (K). 2. Check the CRUM PWB part of the Imaging Unit (K). Is the connection terminal of the CRUM PWB part in the Imaging Unit (K) damaged? Replace the Imaging Unit (K)). Go to step 3. 3. Check the Imaging Unit CRUM Connector Assembly. Is the connection terminal of the Imaging Unit CRUM Connector Assembly damaged? Replace the Imaging Unit CRUM Connector Assembly. Go to step 4. 4. Check the connection between the Imaging Unit CRUM Connector Assembly and MCU PWB. Are the connectors P/J4762, P/J4761, and P/J476 connected securely? Go to step 5. Connect the connectors P/J4762, P/J4761, and P/J476. 5. Check the conductivity between the Imaging Unit CRUM Connector Assembly and Relay Connector. Is the connection between P/J4762 <=> P/J4761 conducting properly? Go to step 6. Replace the Imaging Unit CRUM Connector Assembly. 6. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4761 <=> P/J476 conducting properly? Replace the MCU PWB. Replace the Main Harness Assembly.
  • Code: 091-916
  • Description: (K) Imaging Unit CRUM Data Mismatch Fail A Imaging Unit that’s meant for another region is being used (ID number mismatch). Incorrect Data in the CRUM Authentication Area.
  • Causes: • Imaging Unit (K), PL 6.1.4
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit (K)). Is there an Imaging Unit other than for (K) color installed? Or, is there an Imaging Unit for other than this printer installed? Replace the Imaging Unit (K)). Reinstall the Imaging Unit (K).
  • Code: 091-917, 091-920
  • Description: (Y) Imaging Unit Error: Error Imaging Unit (Y) error has occurred due to one of the following problems. • Communication error of the CRUM for Imaging Unit (Y) • CRUM failure for Imaging Unit (Y). The data written to the Imaging Unit (Y) CRUM and the data read from the Imaging Unit (Y) CRUM do not match. • 091-917: Imaging Unit Y CRUM Communication Fail • 091-920: Imaging Unit Y CRUM Data Broken Fail
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1 • Imaging Unit CRUM Connector Assembly, PL 6.1.6 • CRUM X Harness Assembly (Y/ M/ C), PL 6.1.15 • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit). Is the Imaging Unit (Y) installed properly, with no debris at the contact point between the Imaging Unit CRUM Connector Assembly and the CRUM PWB in the Imaging Unit (Y)? Go to step 2. Reinstall the Imaging Unit (Y). 2. Check the CRUM PWB part of the Imaging Unit. Is the connection terminal of the CRUM PWB part in the Imaging Unit (Y) damaged? Replace the Imaging Unit (Y)). Go to step 3. 3. Check the Imaging Unit CRUM Connector Assembly. Is the connection terminal of the Imaging Unit CRUM Connector Assembly damaged? Replace the Imaging Unit CRUM Connector Assembly. Go to step 4. 4. Check the connection between the Imaging Unit CRUM Connector Assembly and MCU PWB. Are the connectors P/J4552, P/J4551, and P/J455 connected securely? Go to step 5. Connect the connectors P/J4552, P/J4551, and P/J455. 5. Check the conductivity between the Imaging Unit CRUM Connector Assembly and Relay Connector. Is the connection between P/J4552 <=> P/J4551 conducting properly? Go to step 6. Replace the CRUM X Harness Assembly (Y/ M/ C). 6. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4551 <=> P/J455 conducting properly? Replace the MCU PWB. Replace the Main Harness Assembly.
  • Code: 091-918, 091-922
  • Description: (M) Imaging Unit Error: Error Imaging Unit (M) error has occurred due to one of the following problems. • Communication error of the CRUM for Imaging Unit M. • The data written to the Imaging Unit (M) CRUM and the data read from the Imaging Unit (M) CRUM do not match.
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1 • Imaging Unit CRUM Connector Assembly, PL 6.1.6 • CRUM X Harness Assembly (Y/ M/ C), PL 6.1.15 • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit (M)). Is the Imaging Unit (M) installed properly, with no debris at the contact point between the Imaging Unit CRUM Connector Assembly and the CRUM PWB in the Imaging Unit (M)? Go to step 2. Reinstall the Imaging Unit (M). 2. Check the CRUM PWB part of the Imaging Unit. Is the connection terminal of the CRUM PWB part in the Imaging Unit (M) damaged? Replace the Imaging Unit (M)). Go to step 3. 3. Check the Imaging Unit CRUM Connector Assembly. Is the connection terminal of the Imaging Unit CRUM Connector Assembly damaged? Replace the Imaging Unit CRUM Connector Assembly. Go to step 4. 4. Check the connection between the Imaging Unit CRUM Connector Assembly and the MCU PWB. Are the connectors P/J4553, P/J4551, and P/J455 connected securely? Go to step 5. Connect the connectors P/J4553, P/J4551, and P/J455. 5. Check the conductivity between the Imaging Unit CRUM Connector Assembly and Relay Connector. Is the connection between P/J4553 <=> P/J4551 conducting properly? Go to step 6. Replace the CRUM X Harness Assembly (Y/ M/ C). 6. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4551 <=> P/J455 conducting properly? Replace the MCU PWB. Replace the Main Harness Assembly.
  • Code: 091-919, 091-923
  • Description: (C) Imaging Unit Error: Error Imaging Unit (C) error has occurred due to one of the following problems. • Communication error of the CRUM for Imaging Unit (C). • CRUM failure for Imaging Unit (C). The data written to the Imaging Unit (C) CRUM and the data read from the Imaging Unit (C) CRUM do not match. • 091-919: Imaging Unit C CRUM Communication Fail • 091-923: Imaging Unit C CRUM Data Broken Fail
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1 • Imaging Unit CRUM Connector Assembly, PL 6.1.6 • CRUM X Harness Assembly (Y/ M/ C), PL 6.1.15 • MCU PWB, PL 12.1.15 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation of the Imaging Unit). Is the Imaging Unit (C) installed properly, with no debris at the contact point between the Imaging Unit CRUM Connector Assembly and the CRUM PWB in the Imaging Unit (C)? Go to step 2. Reinstall the Imaging Unit (C). 2. Check the CRUM PWB part of the Imaging Unit. Is the connection terminal of the CRUM PWB part in the Imaging Unit (C) damaged? Replace the Imaging Unit (C)). Go to step 3. 3. Check the Imaging Unit CRUM Connector Assembly. Is the connection terminal of the Imaging Unit CRUM Connector Assembly damaged? Replace the Imaging Unit CRUM Connector Assembly. Go to step 4. 4. Check the connection between the Imaging Unit CRUM Connector Assembly and the MCU PWB. Are the connectors P/J4554, P/J4551, and P/J455 connected securely? Go to step 5. Connect the connectors P/J4554, P/J4551, and P/J455. 5. Check the conductivity between the Imaging Unit CRUM Connector Assembly and Relay Connector. Is the connection between P/J4554 <=> P/J4551 conducting properly? Go to step 6. Replace the CRUM X Harness Assembly (Y/ M/ C). 6. Check the conductivity between the Relay Connector and MCU PWB. Is the connection between P/J4551 <=> P/J455 conducting properly? Replace the MCU PWB. Replace the Main Harness Assembly.
  • Code: 091-921
  • Description: (K) Imaging Unit Error: Detached The Imaging Unit (K) CRUM is not in the proper position (loose CRUM).
  • Causes: • Imaging Unit (K), PL 6.1.4
  • Troubleshooting Guides: 1. Reinstall the Imaging Unit (K)).
  • Code: 091-927, 091-928, 091-929
  • Description: (Y/ M/ C) Imaging Unit Error: Detached The (Y/ M/ C) Imaging Unit CRUM is loose. • 091-927: Imaging Unit Y CRUM Not Position • 091-928: Imaging Unit M CRUM Not Position • 091-929: Imaging Unit C CRUM Not Position
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Replace the Imaging Unit (Y/ M/ C)).
  • Code: 091-932, 091-933, 091-934
  • Description: (Y/ M/ C) Imaging Unit Error: Life End The (Y/ M/ C) Imaging Unit Life End error has occurred due to one of the following problems. • Imaging Unit (Y/ M/ C) Quality End of Life • The Imaging Unit life end is detected. • 091-932: Imaging Unit Y End Of Life • 091-933: Imaging Unit M End Of Life • 091-934: Imaging Unit C End Of Life
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1
  • Troubleshooting Guides: 1. Replace the Imaging Unit (Y/ M/ C)).
  • Code: 092-316
  • Description: Environment (Temp/ Humidity) Sensor Error The Environment (external) Sensor temperature error (low temp/ high temp).
  • Causes: • MCU PWB, PL 12.1.15 • Temp/ Humidity (Environmental) Sensor, PL 12.2.18 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the installation of the Temp/ Humidity (Environmental) Sensor Sensor). Is the Temp/ Humidity Sensor installed properly? Go to step 2. Reinstall the Humidity Sensor. 2. Check the connection between the Temp/ Humidity Sensor and MCU PWB. Are the connectors P/J4651B and P/J465A connected securely? Go to step 3. Connect the connectors P/J4651B and P/J465A. 3. Check the conductivity between the Temp/ Humidity Sensor and MCU PWB. Is the connection between P/J4651B <=> P/J465A conducting properly? Go to step 4. Replace the Main Harness Assembly. 4. Check the voltage supply (+5VDC) to the Temp/ Humidity Sensor. Measure the voltage between the MCU PWB GND <=> P/J465A-B4. Is there a voltage (approx. +5VDC) output? Go to step 5. Go to +5VDC Power Troubleshooting. 5. Replace the Temp/ Humidity Sensor Sensor). Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 092-317
  • Description: Temperature Sensor Error The Temperature (internal) Sensor temperature error (low temp/ high temp).
  • Causes: • Temperature Sensor (CTD Sensor Assembly Kit), PL 9.1.98 • MCU PWB, PL 12.1.15 • Main CTD Harness Assembly, PL 12.3.8
  • Troubleshooting Guides: 1. Check the installation of the CTD Sensor Assembly. Is the CTD Sensor Assembly installed properly? Go to step 2. Reinstall the CTD Sensor Assembly. 2. Check the connection between the CTD Sensor Assembly and MCU PWB. Is the connector P/J4561 connected securely? Go to step 3. Connect the connector P/J4561. 3. Check the conductivity between the CTD Sensor Assembly and MCU PWB. Is the connection between P/J4561 <=> P/J456 conducting properly? Go to step 4. Replace the Main CTD Harness Assembly. 4. Check the connection in the CTD Sensor Assembly. Is the connector P/J4563 connected securely? Go to step 5. Connect the connector P/J4563. 5. Replace the CTD Sensor Assembly. Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 092-318 … 092-321
  • Description: (Y/ M/ C/ K) Image Adjustment Patch Error (Y/ M/ C) image adjustment patch error has occurred. • The Y image adjustment patch is light. • The M image adjustment patch is light. • The C image adjustment patch is light. • The K image adjustment patch is light. • 092-318: Patch Y Fail • 092-319: Patch M Fail • 092-320: Patch M Fail • 092-321: Patch M Fail
  • Causes: • Imaging Unit (Y/ M/ C), PL 6.1.1 • Imaging Unit (K), PL 6.1.4 • Toner Cartridge Assembly (Y/ M/ C/ K), PL 8.1.1~PL 8.1.4 • Developer Housing Assembly (Y/ M/ C/ K), PL 8.1.5~PL 8.1.8 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Remove the Toner Cartridge Assembly (Y/ M/ C/ K)). Shake the Toner Cartridge a few times, and then reinstall it. Does the error persist? Go to step 2. Troubleshooting complete. 2. Replace the Toner Cartridge Assembly (Y/ M/ C/ K)). Does the error persist? Go to step 3. Troubleshooting complete. 3. Check the installation state of the Imaging Unit. Remove the Imaging Unit (Y/ M/ C/ K). Is the Imaging Unit installed properly, with no contamination at the contact points and in contact with the left and right Guides? Go to step 4. Clean the contact points. Reinstall the Imaging Unit (Y/ M/ C/ K)). 4. Replace the Imaging Unit (Y)). Does the error persist? Go to step 5. Troubleshooting complete. 5. Replace the Developer Housing Assembly (Y/ M/ C/ K)). Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 093-301
  • Description: Cover Open: Toner Cover Open Toner Cover Interlock Open.
  • Causes: • Toner Cover Interlock Switch Assembly, PL 8.1.99 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Top Harness Assembly, PL 12.2.24
  • Troubleshooting Guides: 1. Check the Toner Cover Interlock Switch operation. Perform DC330 Component Control [041-302] to check the operation of the Toner Cover Interlock Switch. Is it working properly? Replace the MCU PWB. Go to step 2. 2. Check the connection between the Toner Cover Interlock Switch and LVPS PWB. Are the connectors P/J5291 and P/J529 connected securely? Go to step 3. Connect the connectors P/J5291 and P/J529. 3. Check the conductivity between the Toner Cover Interlock Switch and LVPS PWB. Is the connection between P/J5291 <=> P/J529 conducting properly? Go to step 4. Replace the Top Harness Assembly. 4. Check the voltage supply (+5VDC) to the Toner Cover Interlock Switch. Measure the voltage between the LVPS PWB GND <=> P/J529-1. Is there a voltage (approx. +5VDC) output? Close the Interlock Switch and check. Replace the Toner Cover Interlock Switch. Replace the LVPS PWB.
  • Code: 093-302
  • Description: Cover Open: Waste Cover Open Waste Cover Interlock Open.
  • Causes: • Waste Cartridge (Waste Toner Cartridge Assembly), PL 9.1.1 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Waste Cartridge Switch Assembly Kit, PL 12.2.3 • Top Harness Assembly, PL 12.2.24
  • Troubleshooting Guides: 1. Check the installation of the Waste Cartridge. Is the Waste Cartridge installed properly? Go to step 2. Reinstall the Waste Cartridge. 2. Check the Waste Cartridge Set Switch operation. Perform DC330 Component Control [041-301] to check the operation of the Waste Cartridge Set Switch. Is it working properly? Replace the MCU PWB. Go to step 3. 3. Check the connection between the Waste Cartridge Set Switch and LVPS PWB. Are the connectors P/J5225 and P/J522 connected securely? Go to step 4. Connect the connectors P/J5225 and P/J522. 4. Check the voltage supply (+5VDC) to the Waste Cartridge Set Switch. Measure the voltage between the LVPS PWB GND <=> P/J522-5. Is there a voltage (approx. +5VDC) output? Close the Interlock Switch and check. Replace the Waste Cartridge Set Switch. Replace the LVPS PWB.
  • Code: 093-318 … 093-325
  • Description: (Y/ M/ C/ K) Deve Motor Fail The Developer Motor (Y/ M/ C/ K) rotation error was detected. • 093-318: Deve Y Motor Fail • 093-319: Deve M Motor Fail • 093-320: Deve K Motor Fail • 093-325: Deve C Motor Fail
  • Causes: • Developer Motor PWB, PL 11.1.16 • Developer Motor Assembly, PL 11.1.17 • Developer Motor Harness Assembly, PL 11.1.24 • MCU PWB, PL 12.1.15 • LVPS PWB, PL 12.2.1 • Main Harness Assembly, PL 12.3.1
  • Troubleshooting Guides: 1. Check the Developer Motor (Y/ M/ C/ K) operation. Perform DC330 Component Control to check the rotation of the Deve Motor (Y/ M/ C/ K). • (Y) Developer Motor [091-007] • (M) Developer Motor [091-009] • (C) Developer Motor [091-011] • (K) Developer Motor [091-003] Is the Motor working properly? Replace the MCU PWB. Go to step 2. 2. Check the connection between the Developer Motor (Y/ M/ C/ K) and Developer Motor PWB. Is the Flat Cable connected securely? Go to step 3. Connect the Flat Cable. 3. Check the connections between the Developer Motor PWB and MCU PWB, as well as between the Developer Motor PWB and LVPS PWB. Are the connectors P/J474, P/J4741, P/J524, P/J5248, and P/J5241 connected securely? Go to step 4. Connect the connectors P/J474, P/J4741, P/J524, P/J5248, and P/J5241. 4. Check the conductivity between the Developer Motor PWB and Relay Connector. Is the connection between P/J5241 <=> P/J5248 conducting properly? Go to step 5. Replace the Developer Motor Harness Assembly. 5. Check the conductivity between the Developer Motor PWB and MCU PWB. Is the connection between P/J4741 <=> P/J474 conducting properly? Go to Step 6 Replace the Developer Motor Harness Assembly. 6. Check the conductivity between the Relay Connector and LVPS PWB. Is the connection between P/J5248 <=> P/J524 conducting properly? Go to Step 7 Replace the Main Harness Assembly. 7. Check the voltage supply (+3.3VDC) to the Developer Motor PWB. Measure the voltage between the MCU PWB GND <=> P/J474-1. Is there a voltage (approx. +3.3VDC) output? Go to Step 8 Go to +3.3VDC Power Troubleshooting. 8. Check the voltage supply (+24VDC) to the Developer Motor PWB. Measure the voltages between the LVPS PWB GND <=> P/J524-9 and between LVPS PWB GND <=> P/J524-11. Is there a voltage (approx. +24VDC) output? Close the Interlock Switch and check. Replace the following parts in sequence: • Developer Motor Assembly) • Developer Motor PWB Replace the LVPS PWB.
  • Code: 093-413 … 093-420
  • Description: (K/ Y/ M/ C) Developer Error: Life End The Developer count has reached life end. • 093-413: Deve Life End (K) • 093-418: Deve Life End (Y) • 093-419: Deve Life End (M) • 093-420: Deve Life End (C)
  • Causes: • Developer Housing Assembly (Y), PL 8.1.5 – PL 8.1.8
  • Troubleshooting Guides: 1. Replace the Housing Developer Assembly). 2. Perform DC135 HFSI and reset the following Life Counters for the Developer Housing Assembly (Y/ M/ C/ K). • 950-812 – (K) Developer PV 000 • 950-828 – (K) Developer Roundtime 000 • 950-844 – (K) Developer Pixel Count 000 • 950-808 – (Y) Developer PV • 950-816 – (Y) Developer Roundtime • 950-832 – (Y) Developer Pixel Count • 950-804 – (M) Developer PV • 950-820 – (M) Developer Roundtime • 950-836 – (M) Developer Pixel Count • 950-808 – (C) Developer PV • 950-824 – (C) Developer Roundtime • 950-840 – (C) Developer Pixel Count
  • Code: 093-426 … 093-429
  • Description: (Y/ M/ C/ K) Toner ID Error (Y/ M/ C/ K) Toner ID error has occurred for one of the following problems. • Toner (Y/ M/ C/ K) CRUM Comm Fail • Toner (Y/ M/ C/ K) CRUM Data Broken • Toner (Y/ M/ C/ K) CRUM Data Mismatch • A Toner Cartridge that’s meant for another region is being used (ID number mismatch). • Incorrect Data in the Toner Cartridge (Y/ M/ C/ K) CRUM Authentication Area. • 093-426: Toner K CRUM Trouble Info • 093-427: Toner Y CRUM Trouble Info • 093-428: Toner M CRUM Trouble Info • 093-429: Toner C CRUM Trouble Info
  • Causes: • Toner Cartridge Assembly (Y/ M/ C/ K), PL 8.1.1 – PL 8.1.4
  • Troubleshooting Guides: 1. Check the installation of the Toner Cartridge (Y/ M/ C/ K)). Is there a Toner Cartridge other than for the failed color (Y/ M/ C/ K) installed? Or, is there a Toner Cartridge for other than this printer installed? Replace with the correct the Toner Cartridge (Y/ M/ C/ K). Reinstall the Toner Cartridge (Y/ M/ C/ K).
  • Code: 093-912, 093-963
  • Description: (K) Toner Cartridge Error: Life End Toner Cartridge error has occurred for one of the following problems. • The Black Dispense Motor rotation time had reached the specified value and the toner has ran out. • Toner K is Empty and any of the Toner YMC is also Empty. • 093-912: Toner K Empty • 093-963: Plural Toner Empty
  • Causes: • Toner Cartridge Assembly (K), PL 8.1.4
  • Troubleshooting Guides: 1. Replace the Toner Cartridge (K)).
  • Code: 093-913 … 093-916
  • Description: (Y/ M/ C/ K) Toner Cartridge Error: Detached The (Y/ M/ C/ K) Toner Cartridge CRUM is loose. • 093-913: Toner CRUM Not Position Y • 093-914: Toner CRUM Not Position M • 093-915: Toner CRUM Not Position C • 093-916: Toner CRUM Not Position K
  • Causes: • Toner Cartridge Assembly (K), PL 8.1.4
  • Troubleshooting Guides: 1. Reinstall the Toner Cartridge (Y/ M/ C/ K)).
  • Code: 093-924 … 093-935
  • Description: (Y/ M/ C/ K) Toner Cartridge Error: Error Toner Cartridge (Y/ M/ C/ K) CRUM communication error has occurred due to one of the following problems. • Toner Cartridge CRUM data Read/Write error. • The data written to the Toner Cartridge (Y/ M/ C/ K) CRUM and the data read from the Toner Cartridge (Y/ M/ C/ K) CRUM do not match • 093-924: Toner CRUM Comm Fail K • 093-925: Toner CRUM Data Broken Fail K • 093-927: Toner CRUM Comm Fail Y • 093-928: Toner CRUM Comm Fail M • 093-929: Toner CRUM Comm Fail C • 093-933: Toner CRUM Data Broken Fail Y • 093-934: Toner CRUM Data Broken Fail M • 093-935: Toner CRUM Data Broken Fail C
  • Causes: • Toner Cartridge Assembly (Y), PL 8.1.1 – PL 8.1.3 • Toner CRUM Connector Assembly, PL 8.1.13 • Toner CRUM Harness Assembly, PL 8.1.18 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the installation of the Toner Cartridge (Y/ M/ C/ K)). Is the Toner Cartridge (Y/ M/ C/ K) installed properly, with no foreign substances at the contact point between the Toner CRUM Connector Assembly and the CRUM PWB in the Toner Cartridge (Y/ M/ C/ K)? Go to step 2. Reinstall the Toner Cartridge (Y/ M/ C/ K). 2. Check the CRUM PWB part of the Toner Cartridge (Y/ M/ C/ K). Is the connection terminal of the CRUM PWB part in the Toner Cartridge (Y/ M/ C/ K) damaged? Replace the Toner Cartridge (Y/ M/ C/ K)). Go to step 3. 3. Check the Toner CRUM Connector Assembly. Is the connection terminal of the Toner CRUM Connector Assembly damaged? Replace the Toner CRUM Connector Assembly. Go to step 4. 4. Check the connection between the Toner CRUM Connector Assembly and MCU PWB. Are the connectors connected securely? • (Y) Toner CRUM: P/J4541 <=> P/J454 • (M) Toner CRUM: P/J4542 <=> P/J454 • (C) Toner CRUM: P/J4543 <=> P/J454 • (K) Toner CRUM: P/J4544 <=> P/J454 Go to step 5. Connect the connectors: • (Y) Toner CRUM: P/J4541 and P/J454 • (M) Toner CRUM: P/J4542 <=> P/J454 • (C) Toner CRUM: P/J4543 <=> P/J454 • (K) Toner CRUM: P/J4544 <=> P/J454 5. Check the conductivity between the Toner CRUM Connector Assembly and MCU PWB. Is the connection between the connectors conducting properly? • (Y) Toner CRUM: P/J4541 <=> P/J454 • (M) Toner CRUM: P/J4542 <=> P/J454 • (C) Toner CRUM: P/J4543 <=> P/J454 • (K) Toner CRUM: P/J4544 <=> P/J454 Replace the MCU PWB. Replace the Toner CRUM Harness Assembly.
  • Code: 093-926 … 093-939
  • Description: (Y/ M/ C/ K) Toner ID Error (Y/ M/ C/ K) Toner ID error has occurred for one of the following problems. • Toner (Y/ M/ C/ K) CRUM Comm Fail • Toner (Y/ M/ C/ K) CRUM Data Broken • Toner (Y/ M/ C/ K) CRUM Data Mismatch • A Toner Cartridge that’s meant for another region is being used (ID number mismatch). • Incorrect Data in the Toner Cartridge (Y/ M/ C/ K) CRUM Authentication Area. • 093-926: Toner CRUM Data Mismatch Fail K • 093-937: Toner CRUM Data Mismatch Fail Y • 093-938: Toner CRUM Data Mismatch Fail M • 093-939: Toner CRUM Data Mismatch Fail C
  • Causes: • Toner Cartridge Assembly (Y/ M/ C/ K), PL 8.1.1 – PL 8.1.4
  • Troubleshooting Guides: 1. Check the installation of the Toner Cartridge (Y/ M/ C/ K)). Is there a Toner Cartridge other than for the failed color (Y/ M/ C/ K) installed? Or, is there a Toner Cartridge for other than this printer installed? Replace with the correct the Toner Cartridge (Y/ M/ C/ K). Reinstall the Toner Cartridge (Y/ M/ C/ K).
  • Code: 094-310
  • Description: CTD Sensor Error CTD Sensor power down.
  • Causes: • CTD Sensor Assembly Kit, PL 9.1.98 • MCU PWB, PL 12.1.15 • Main CTD Harness Assembly, PL 12.3.8
  • Troubleshooting Guides: 1. Check the surface of the CTD Sensor for contamination and foreign substances. Is there any contamination or foreign substances on the Sensor surface of the Left/ Right CTD Sensor section that comprise the CTD Sensor Assembly? Clean and remove any debris on the Sensor surface of the Left/ Right CTD Sensor. Go to step 2. 2. Check the installation of the CTD Sensor Assembly. Is the CTD Sensor Assembly installed properly? Go to step 3. Reinstall the CTD Sensor Assembly. 3. Check the connection between the CTD Sensor Assembly and MCU PWB. Are the connectors P/J4571, P/J4572, and P/J4561 connected securely? Go to step 4. Connect the connectors P/J4571, P/J4572, and P/J4561. 4. Check the conductivity between the CTD Sensor Assembly and MCU PWB. Are the connections between P/J4571 <=> P/J457, between P/J4572 <=> P/J457, and between P/J4561 <=> P/J456 conducting properly? Go to step 5. Replace the Main CTD Harness Assembly. 5. Check the voltage supply (+5VDC) to the CTD Sensor Assembly. Measure the voltages between the MCU PWB GND <=> P/J457-1 and between MCU PWB GND <=> P/J457-6. Is there a voltage (approx. +5VDC) output? Go to step 6. Go to +5VDC Power Troubleshooting. 6. Check the connection in the CTD Sensor Assembly. Are the connectors P/J4573 and P/J4574 connected securely? Go to step 7. Connect the connectors P/J4573 and P/J4574. 7. Replace the CTD Sensor Assembly. Does the error persist? Replace the MCU PWB. Troubleshooting complete.
  • Code: 094-311, 094-420
  • Description: IBT Unit Error: Life End When the IBT Unit HFSI Counter reached the IBT Unit Dead Stop (NVM).
  • Causes: • IBT Unit Kit, PL 9.1.99
  • Troubleshooting Guides: 1. Replace the IBT Unit. 2. Perform DC135 HFSI and reset the following Life Counters for the IBT Unit. • 950-888- IBT Unit PV • 950-892 – IBT Unit Round Time
  • Code: 094-320, 094-321
  • Description: Switching Sensor Failure The Switching Sensor error has occurred due to one of the following problems. • Retract was not detected within the specified time (2400 ms) after the 1st BTR Retract operation has started. • Contact was not detected within the specified time (2400 ms) after the 1st BTR Contact operation had started.
  • Causes: • IBT Retract Cam Assembly, PL 9.1.8 • IBT Unit, PL 9.1.99 • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Check the installation of the IBT Retract Cam Assembly. Is the IBT Retract Cam Assembly installed properly? Go to step 2. Reinstall the IBT Retract Cam Assembly. 2. Check the installation of the IBT Unit. Is the IBT Unit installed properly? Go to step 3. Reinstall the IBT Unit. 3. Check the Belt Retract Sensor operation. Perform DC330 Component Control [094-200] to check the operation of the Belt Retract Sensor. Is the Belt Retract Sensor operating properly? Go to step 4. Go to Belt Retract Sensor. 4. Check the Belt Retract Motor operation. Perform DC330 Component Control [094-001] to check the operation of the Belt Retract Motor. Is the Belt Retract Motor operating normally? Replace the MCU PWB. Go to Belt Retract Motor.
  • Code: 094-422
  • Description: 2nd BTR Error: Life End When the 2nd BTR Unit (Transfer Roller) HFSI Counter reached the 2nd BTR Unit End Warning (NVM).
  • Causes: • Transfer Roller (2nd BTR Unit), PL 4.3.18
  • Troubleshooting Guides: 1. Replace the Transfer Roller). 2. Perform DC135 HFSI and reset the following Life Counters for the 2nd BTR. • 950-872 – 2nd BTR PV
  • Code: 102-356
  • Description: EWS Soft Fail An EWS-related fatal error. A problem has occurred in the software processing and it is unable to continue with the subsequent processes.
  • Causes:
  • Troubleshooting Guides: 1. Perform the following sequences: a. Go to Common System Fail. b. Go to HDD System Fail. c. Go to Network Troubleshooting. d. Go to USB Port Testing.
  • Code: 116-220
  • Description: Downloader Initialization Failure during Transition to Download Mode (In Normal mode and in Forced Download mode). When transitioning to the Download mode, the Downloader, which is a software that performs download in the ESS, has failed during the software startup initialization.
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Check the connection of the System Memory on the I/P PWB. If the problem occurs frequently, replace the I/P PWB PWB). If the problem persists, go to Common System Fail.
  • Code: 116-312, 116-313
  • Description: Encryption error has occurred due one of the following problems. • During start up, an irregularity was detected in the HDD Encryption Key. • Although the Encryption Key is set, the HDD itself is not encrypted. • 116-312: <HDD Encrypt Key Fail> During start up, an irregularity was detected in the Encryption Key • 116-313: <HDD Encrypt Key Fail> During start up, an irregularity was detected in the Encryption Key
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Go to HDD System Fail. After the recovery, set the HDD Encryption Key correctly.
  • Code: 116-314
  • Description: Ethernet Address Fail An ethernet error was detected.
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Check the installation of the SEEPROM on the I/P PWB. If the problem persists, perform the following procedure to correct it. • Go to Network Troubleshooting. • Go to USB Port Testing.
  • Code: 116-315
  • Description: ESS RAM DIMM #1 W/R Check Fail An error was detected when performing W/R to the I/P PWB RAM DIMM #1.
  • Causes: • 1 GB DDR2 DIMM (Standard), PL 12.4.2 • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. • Remove and reinstall the I/P PWB RAM DIMM #1. • Replace the I/P PWB RAM DIMM #1). • Replace the I/P PWB PWB).
  • Code: 116-317
  • Description: Standard ROM DIMM Check Fail An error was detected at the Standard ROM DIMM check.
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the I/P PWB PWB).
  • Code: 116-321, 116-322
  • Description: Encryption error has occurred due one of the following problems. • A problem has occurred in the software processing and it is unable to continue with the subsequent processes. Other Adjustments (reference) The counter number that is used in the Counter Report has exceeded the defined value. • A problem has occurred in the software processing and it is unable to continue with the subsequent processes. • 116-321: SysCon Error • 116-322: WebDAV-related Fatal Error
  • Causes:
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-323
  • Description: ESS NVRAM W/R Check Fail During the Read/Write check at power ON, an ESS-NVRAM PWB hardware error was detected by the OS/ DD.
  • Causes: • 1 GB DDR2 DIMM (Standard), PL 12.4.2 • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Remove and reinstall the NVRAM I/P PWB) and turn On the power. 2. If the 116-323 problem persists, replace the NVRAM PWB). 3. As 116-334 will occur after the NVRAM I/P PWB is replaced, go to 116-334 ESS NVRAM Data Compare Fail. 4. If the 116-323 problem still persists, go to 016-782/ 016-784 Fail.
  • Code: 116-324
  • Description: Exception Fail A fatal software exception process has occurred in the CPU of the Controller PWB. The cause of this is largely due to Controller software malfunction.
  • Causes: • 1 GB DDR2 DIMM (Standard), PL 12.4.2 • I/P PWB, PL 12.4.1 • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Turn Off the printer power, then turn On the power while pressing the Energy Saver button and the Down button. Maintain that state for 6 seconds and the printer will delete the print data that causes the error and then reboots itself. 2. If the problem persists, perform the following, pull out and reinsert or replace the RAM DIMM). Corrective actions when the problem occurred at power On: 3. Check whether the error persists after returning from Energy Saver Mode and take a note on the result, and then perform steps 1 to 6 in Common System Fail. 4. If the problem persists, prepare for the recovery operation since the system may be recovered by the procedures in HDD System Fail. Check with the customer whether important data is stored on the HDD. 5. If no important data is stored on the HDD, perform the procedure in HDD System Fail. If the problem persists, reinstall the removed HDD). 6. If important data is stored on the HDD, replace it with the HDD you brought and turn the printer power Off and On. (If you have brought an HDD.) If the problem persists, reinstall the HDD and replace the I/P PWB PWB).
  • Code: 116-325
  • Description: ESS Fan Fail Irregularity has occurred in the ESS Fan rotation.
  • Causes: • Image Processor PWB, PL 12.4.1 • I/P PWB Fan, PL 12.4.6
  • Troubleshooting Guides: 1. Replace the ESS Fan. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 116-328, 116-329
  • Description: System error has occurred due to one of the following problems. • Failure was detected in the level 2 cache within the CPU. • A serial I/F related system call error was detected. • 116-328: CPU Built-in Level 2 Cache Failure • 116-329: <Serial I/F-related Fatal Error> System call error related to Serial I/F.
  • Causes:
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-330
  • Description: HDD File System Fail HDD checksum error at power On or the HDD was not formatted.
  • Causes:
  • Troubleshooting Guides: 1. Disconnect and reconnect the HDD harness, check the installation of the HDD and install it securely. Perform Steps 1 to 6 of Common System Fail. If the problem persists, go to the next step. 2. If the problem persists, perform the forced initialization by special booting. • Startup by Force Spool Range (HDD) Initialization It is the operation to forcedly clear the HDD when the printer is started up. [Operation or Details] a. Turning the power ON while pressing the [Energy Saver] and [Down] buttons at the same time initializes the data stored in the HDD Partition No. 4. b. Initialization by special booting in this item targets only on the previously specified area in the HDD partition and does not affect the other areas. Here, perform the same operation where the error occurred. 3. If the problem persists, perform the forced formatting by special booting. • Starting the forced HDD formatting (this procedure should not be let known to the users) This operation forcedly restores the HDD to the partition status at factory settings. Perform HDD formatting by turning the power On while pressing the Energy Saver button, Up + Down buttons at the same time. Here, perform the same operation where the error occurred. 4. If the problem persists, replace the HDD and perform the same operation where the error had occurred. 5. If the problem persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 6. Return the NVM that was set in Step 1 (DC131 NVM Read/ Write [700-530]: Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-331
  • Description: Invalid Log Info Log related error was detected.
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Remove the HDD). Turn the printer power On then Off. Reinstall the HDD and turn the printer power On. 2. If the problem persists, go to HDD System Fail.
  • Code: 116-332
  • Description: ESS Standard ROM Error An ESS On Board Standard ROM error was detected.
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Remove and reinstall the Standard ROM) on the I/P PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 116-334
  • Description: ESS NVRAM Data Compare Fail During the Read/Write check at power ON, “ESSNVRAM with default factory settings installed” or “ESS-NVRAM data is incorrect” was detected in the System Cont. At the detection of 116-334, because the ESSNVRAM data has been overwritten by the initialization data in the ESS-ROM, turning the power OFF and ON after that causes mismatches in 3 locations for each type that results in a system fail (124-3xx).
  • Causes: • 1 GB DDR2 DIMM, PL 12.4.2 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Because the mismatch error 124-3xx in 3 locations for each type are expected at the power Off/ On after the detection of 116-334, follow the procedure for the appropriate Fault Code and use the suitable DC132 Machine Serial Number Settings to fix the problem. 2. If the 116-334 persists after turning the power Off and On, remove and reinstall the NVRAM I/P PWB) and turn On the printer power. 3. If the problem still persists, replace the NVRAM I/P PWB). 4. If the problem still persists, replace the I/P PWB PWB). 5. If the 116-334 problem persists, go to Common System Fail.
  • Code: 116-336, 116-337
  • Description: NVRAM error has occurred due to one of the following problems. • An error was detected when HDD was accessed. • A problem has occurred in the software processing and it is unable to continue with the subsequent processes. • 116-336: <Redirector Fail> HDD failure detected in the Redirector. • 116-337: SNTP-related Fatal Error
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Disconnect and reconnect the HDD harness, check the installation of the HDD and install it securely. Perform Steps 1 to 6 of Common System Fail. If the problem persists, go to the next step. 2. If the problem persists, perform the forced initialization by special booting. • Startup by Force Spool Range (HDD) Initialization It is the operation to forcedly clear the HDD when the printer is started up. [Operation or Details] a. Turning the power ON while pressing the [Energy Saver] and [Down] buttons at the same time initializes the data stored in the HDD Partition No. 4. b. Initialization by special booting in this item targets only on the previously specified area in the HDD partition and does not affect the other areas. Here, perform the same operation where the error occurred. 3. If the problem persists, perform the forced formatting by special booting. • Starting the forced HDD formatting (this procedure should not be let known to the users) This operation forcedly restores the HDD to the partition status at factory settings. Perform HDD formatting by turning the power On while pressing the Energy Saver button, Up + Down buttons at the same time. Here, perform the same operation where the error occurred. 4. If the problem persists, replace the HDD and perform the same operation where the error had occurred. 5. If the problem persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 6. Return the NVM that was set in Step 1 (DC131 NVM Read/ Write [700-530]: Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-338
  • Description: JBA Fatal Error A problem has occurred in the software processing and it is unable to continue with the subsequent processes.
  • Causes:
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-340
  • Description: Memory Not Enough Insufficient memory was detected at initialization. A PS option requiring an additional memory was installed but memory was not added.
  • Causes:
  • Troubleshooting Guides: 1. Remove the PostScript Option then reboot the printer to operate, and increase the Controller memory permanently.
  • Code: 116-341
  • Description: ROM VER Incorrect The versions of several installed ROM DIMM are incorrect. An unusable combination of ROM DIMMs are installed. When installing multiple ROM DIMMs, it is necessary to match both the major versions and the minor versions.
  • Causes:
  • Troubleshooting Guides: 1. Check the versions of the multiple ROM DIMMs installed and replace them with an appropriate combination of DIMMs. When installing multiple ROM DIMMs, it is necessary to match both the major versions and the minor versions.
  • Code: 116-342
  • Description: SESAMi Manager Fail An SNMP Agent-related fatal error. A problem has occurred in the software processing and it is unable to continue with the subsequent processes.
  • Causes:
  • Troubleshooting Guides: 1. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update).
  • Code: 116-343
  • Description: Main PWBA IC Fail Irregularity was detected in the IC of the I/P PWB.
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-348, 116-349, 116-351
  • Description: System error has occurred due to one of the following problems. • A response such as system function recall error was detected. • An error when calling the Pflite function at SIF. • A problem has occurred in the software processing and it is unable to continue with the subsequent processes.
  • Causes:
  • Troubleshooting Guides: 1. Turn the printer power Off and On. Perform the same operation and check whether the problem is reoccurring. 2. If the problem persists, go to Common System Fail. If Common System Fail procedure is NG, go to Network Troubleshooting.
  • Code: 116-353
  • Description: HDD Physical Fail During start up, a physical irregularity was detected in the HDD, and it is unable to start up.
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Disconnect and reconnect the HDD harness, check the installation of the HDD and install it securely. Perform Steps 1 to 6 of Common System Fail. If the problem persists, go to the next step. 2. If the problem persists, perform the forced initialization by special booting. • Startup by Force Spool Range (HDD) Initialization It is the operation to forcedly clear the HDD when the printer is started up. [Operation or Details] a. Turning the power ON while pressing the [Energy Saver] and [Down] buttons at the same time initializes the data stored in the HDD Partition No. 4. b. Initialization by special booting in this item targets only on the previously specified area in the HDD partition and does not affect the other areas. Here, perform the same operation where the error occurred. 3. If the problem persists, perform the forced formatting by special booting. • Starting the forced HDD formatting (this procedure should not be let known to the users) This operation forcedly restores the HDD to the partition status at factory settings. Perform HDD formatting by turning the power On while pressing the Energy Saver button, Up + Down buttons at the same time. Here, perform the same operation where the error occurred. 4. If the problem persists, replace the HDD and perform the same operation where the error had occurred. 5. If the problem persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 6. Return the NVM that was set in Step 1 (DC131 NVM Read/ Write [700-530]: Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-354
  • Description: HDD Product Fail During start up, a Product Code error was detected in the HDD, and it is unable to start up. It is possible that the HDD had been formatted by the printer of a different product.
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. To overwrite to the HDD of another product (HDD System Fail) to perform the special boot forced formatting.
  • Code: 116-355
  • Description: Agent Soft Fail A problem has occurred in the software processing and it is unable to continue with the subsequent processes.
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Turn the printer power Off and On. Perform the same operation and check whether the problem is reoccurring. If the problem persists, go to HDD System Fail.
  • Code: 116-356
  • Description: HDD Format Fail While formatting the HDD, either an out-of-spec HDD was connected or an error has occurred in the HDD.
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Disconnect and reconnect the HDD harness, check the installation of the HDD and install it securely. Perform Steps 1 to 6 of Common System Fail. If the problem persists, go to the next step. 2. If the problem persists, perform the forced initialization by special booting. • Startup by Force Spool Range (HDD) Initialization It is the operation to forcedly clear the HDD when the printer is started up. [Operation or Details] a. Turning the power ON while pressing the [Energy Saver] and [Down] buttons at the same time initializes the data stored in the HDD Partition No. 4. b. Initialization by special booting in this item targets only on the previously specified area in the HDD partition and does not affect the other areas. Here, perform the same operation where the error occurred. 3. If the problem persists, perform the forced formatting by special booting. • Starting the forced HDD formatting (this procedure should not be let known to the users) This operation forcedly restores the HDD to the partition status at factory settings. Perform HDD formatting by turning the power On while pressing the Energy Saver button, Up + Down buttons at the same time. Here, perform the same operation where the error occurred. 4. If the problem persists, replace the HDD and perform the same operation where the error had occurred. 5. If the problem persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 6. Return the NVM that was set in Step 1 (DC131 NVM Read/ Write [700-530]: Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-357, 116-359
  • Description: Software processing error has occurred and it is unable to continue with the subsequent processes. • 116-357: PS Fatal System Error • 116-359: A PLW Fatal Error
  • Causes:
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-361, 116-362
  • Description: HDD error has occurred due to one of the following problems. • The SpoolCont detected an error at HDD access. • A problem has occurred in the software processing and it is unable to continue with the subsequent processes. • 116-361: An SPL HDD Fatal Error • 116-362: SSDP Software Fail
  • Causes:
  • Troubleshooting Guides: 1. Disconnect and reconnect the HDD harness, check the installation of the HDD and install it securely. Perform Steps 1 to 6 of Common System Fail. If the problem persists, go to the next step. 2. If the problem persists, perform the forced initialization by special booting. • Startup by Force Spool Range (HDD) Initialization It is the operation to forcedly clear the HDD when the printer is started up. [Operation or Details] a. Turning the power ON while pressing the [Energy Saver] and [Down] buttons at the same time initializes the data stored in the HDD Partition No. 4. b. Initialization by special booting in this item targets only on the previously specified area in the HDD partition and does not affect the other areas. Here, perform the same operation where the error occurred. 3. If the problem persists, perform the forced formatting by special booting. • Starting the forced HDD formatting (this procedure should not be let known to the users) This operation forcedly restores the HDD to the partition status at factory settings. Perform HDD formatting by turning the power On while pressing the Energy Saver button, Up + Down buttons at the same time. Here, perform the same operation where the error occurred. 4. If the problem persists, replace the HDD and perform the same operation where the error had occurred. 5. If the problem persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 6. Return the NVM that was set in Step 1 (DC131 NVM Read/ Write [700-530]: Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-364
  • Description: Timer Fail A Timer error was detected.
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the I/P PWB PWB).
  • Code: 116-365, 116-366, 116-368
  • Description: Software processing error has occurred due to one of the following problems. • The number of files that was instructed to be input/ output from the HDD have exceeded the number of files that can be simultaneously output. • A problem has occurred in the software processing and it is unable to continue with the subsequent processes. • 116-365: SPL Fatal Error • 116-366: Print Utility Operational Failure and operation failure of the Report Generator • 116-368: Dump Print Fatal Error
  • Causes:
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-377
  • Description: Video DMA Fail Video DMA failure was detected.
  • Causes:
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-380
  • Description: ESS Font ROM DIMM #1 Check Fail En error was detected at the ESS Font ROM DIMM #1 check.
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Remove and reinstall the I/P PWB PWB). Replace the I/P PWB PWB).
  • Code: 116-387
  • Description: MRC HW Fatal Error A fatal error has occurred.
  • Causes: • 1 GB DDR DIMM, PL 12.4.2 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the I/P PWB RAM). 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 116-388
  • Description: No HD that Should Be An HDD error has occurred. Although the configuration requires a HDD, it was detected that the HDD is not installed.
  • Causes: • HDD Productivity Kit, PL 12.4.20
  • Troubleshooting Guides: 1. Disconnect and reconnect the HDD harness, check the installation of the HDD and install it securely. Perform Steps 1 to 6 of Common System Fail. If the problem persists, go to the next step. 2. If the problem persists, perform the forced initialization by special booting. • Startup by Force Spool Range (HDD) Initialization It is the operation to forcedly clear the HDD when the printer is started up. [Operation or Details] a. Turning the power ON while pressing the [Energy Saver] and [Down] buttons at the same time initializes the data stored in the HDD Partition No. 4. b. Initialization by special booting in this item targets only on the previously specified area in the HDD partition and does not affect the other areas. Here, perform the same operation where the error occurred. 3. If the problem persists, perform the forced formatting by special booting. • Starting the forced HDD formatting (this procedure should not be let known to the users) This operation forcedly restores the HDD to the partition status at factory settings. Perform HDD formatting by turning the power On while pressing the Energy Saver button, Up + Down buttons at the same time. Here, perform the same operation where the error occurred. 4. If the problem persists, replace the HDD and perform the same operation where the error had occurred. 5. If the problem persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 6. Return the NVM that was set in Step 1 (DC131 NVM Read/ Write [700-530]: Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-389
  • Description: No Add-On RAM that Should Be RAM error has occurred. Although the configuration (with HDD, etc.) requires an Extension RAM, it was detected that the Extension RAM is not installed.
  • Causes: • 1 GB SO-DIMM (Extension System Memory), PL 12.4.3 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform I/P PWB Diagnostic. Refer to Image Processor (I/P) PWB LEDs. 2. Check the version of the Firmware. If it is not the latest, download the latest firmware (Firmware Update). 3. Turn the power Off and On. 4. Turn the power Off and On by using the breaker (unplug from and plug to the power outlet). 5. If the problem persists, check the installation status of the I/P PWB, MCU PWB, and cable connectors. Reconnect the cables/reinstall the PWB’s as needed, and then perform the same operation where the error had occurred. 6. Turn the power Off, remove and insert the I/P PWB RAM DIMM), then turn the power On again to perform the same operation where the error occurred. 7. If the problem persists after turning the power On, turn the power Off and replace the RAM DIMM). After turning the power On, perform the same operation where the error had occurred. 8. If the problem still persists, replace the I/P PWB PWB) and perform the same operation where the error had occurred. 9. Return the DC131 NVM Read/ Write [700-530]. Reboot Target at Fail Occurrence) to “1”.
  • Code: 116-390
  • Description: Standard ROM and NVM Version Mismatch A mismatch in the versions of the Standard ROM and NVM was detected.
  • Causes:
  • Troubleshooting Guides: 1. Initialize the NVM (DC301 NVM Initialize).
  • Code: 124-310, 124-311
  • Description: Product Number or Serial Number error has occurred due to one of the following problems. • The Product Number that is stored in 3 locations are not initialized. • The Serial Number that is stored in 3 locations are not initialized. • 124-310: Product No. Fail (contents corrupted, the Controller PWB was replaced) • 124-311: Serial No. Fail (contents corrupted, the Controller PWB was replaced)
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-312, 124-313
  • Description: Product Numbers or Serial Numbers error has occurred due to one of the following problems. • At least one of the Product Numbers that is stored in 3 locations is different. • At least one of the Serial Numbers that is stored in 3 locations is different. • 124-312: Product Number fails when at least one Product Number is mismatched. • 124-313: Serial Number fails when at least one Serial Number is mismatched.
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings. 2. Compare the 3 Product Number/ Serial Number. 3. If all 3 are different, replace the MCU PWB. 4. If the problem persists, replace the I/P PWB PWB). 5. If 2 among the 3 are matched, perform DC132 Machine Serial Number Settings to match all 3 values.
  • Code: 124-314
  • Description: Although the IOT speed that is stored in the 3 locations are matched, their values are not set (0). • 124-314: The IOT productivity switch data was not set at all 3 locations. IOT speed fails (Contents corrupted. The PWB was replaced.)
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-315, 124-317
  • Description: Speed mismatch or Product Model Identification data error has occurred due to one of the following problems. • At least one of the IOT Speed that is stored in 3 locations is different. • At least one of the Product a/f Model identification data that is stored in the 3 locations is different. • 124-315: At least one of the IOT productivity switch data was at the 3 locations is different. All IOT speed mismatch. (Contents corrupted. The PWB was replaced.) • 124-317: At least one of the Product a/f Model at the 3 locations is different. All Product Model mismatch. (Contents corrupted. The PWB was replaced.)
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC131 NVM Read/ Write. 2. Compare the following 3 values: • DC131 [700-600] • DC131 [700-601] • DC131 [700-602] 3. Compare the 3 data. If all 3 are different, replace the MCU PWB. 4. If the problem persists, replace the I/P PWB PWB). 5. If 2 among the 3 are matched, perform DC132 Machine Serial Number Settings to match all 3 values.
  • Code: 124-316, 124-318
  • Description: Product a/f Model identification data or Product Type for SW Key error has occurred due to one of the following problems. • Although the Product a/f Model identification data that is stored in the 3 locations are matched, their values are not set (0). • Although the Product Type For SWKey that is stored in the 3 locations are matched, their values are not set (0). • 124-316: The Product a/f Model was not set at all 3 locations. Product Model fails. (Contents corrupted. The PWB was replaced.) • 124-318: The Product Type For SWKey was not set at all 3 locations. Product Type For SWKey fails. (Contents corrupted. The PWB was replaced.)
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-319
  • Description: At least one of the Product Type For SWKey that is stored in 3 locations is different. • 124-319: At least one of the Product Type for SWKey at the 3 locations is different. All Product Type for SWKey Mismatch. (Contents corrupted. The PWB was replaced.)
  • Causes:
  • Troubleshooting Guides: 1. Perform DC131 NVM Read/ Write. 2. Compare the following 3 values: • DC131 [700-606] • DC131 [700-607] • DC131 [700-608] 3. Compare the 3 data. If all 3 are different, replace the MCU PWB. 4. If the problem persists, replace the I/P PWB PWB). 5. If 2 among the 3 are matched, perform DC132 Machine Serial Number Settings to match all 3 values.
  • Code: 124-320
  • Description: SEEPROM Fail Write error has occurred in the SEEPROM on the I/P PWB.
  • Causes: • EEPROM PWB, PL 12.1.18 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Reinstall the EEPROM. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-321
  • Description: Backup SRAM Fail Write error has occurred in the NVM on the I/P PWB.
  • Causes: • Image Processor PWB, PL 12.4.1 • 1 GB DDR2 DIMM, PL 12.4.2
  • Troubleshooting Guides: 1. Reinstall the NVRAM). 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-324
  • Description: All Billings Mismatch The Billing Counters that are stored in multiple locations are all different.
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-325
  • Description: Billing Restoration Fail At least one Billing Counter is not matched and correction is not possible.
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings. 2. Compare the 3 Serial Number. If all 3 are different, replace the MCU PWB. 3. If the problem persists, replace the I/P PWB PWB). 4. If 2 among the 3 are matched, replace the PWB that has the different value.
  • Code: 124-326
  • Description: IOT Speed Not Registered At boot, the status of speed registration procedure for IOT was detected to be 1 or 2.
  • Causes:
  • Troubleshooting Guides: 1. This failure will start the IOT speed change procedure and the user should follow the dialog that is displayed on the UI to enter the SW Key for IOT speed change.
  • Code: 124-327
  • Description: IOT Speed Change SW Fail An irregularity was detected in the middle of the IOT speed change procedure. 1. Failed to transition to Diag Mode 2. Failed at DC132 3. Failed at SEEP-ROM R/W 4. Failed at reboot
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform firmware upgrade (Firmware Update). 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-333
  • Description: ASIC Fail (Panther)/ 124-337 ESS Standard RAM Error RAM error has occurred due to one of the following problems. • Server error was detected. • An ESS On Board Standard RAM error was detected. • 124-333: Panther Error • 124-337: ESS Standard RAM (Standard ROM) Error
  • Causes: • 1 GB DDR2 DIMM, PL 12.4.2
  • Troubleshooting Guides: 1. Reinstall the NVRAM). 2. If the problem still persists, go to Common System Fail.
  • Code: 124-338
  • Description: Same Font ROMs Found The system detected that a duplicate Font ROM was installed.
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the I/P PWB PWB).
  • Code: 124-339
  • Description: ROM DIMM of Another Product Found It was detected that ROM DIMM from other machine models is installed.
  • Causes: • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the I/P PWB PWB).
  • Code: 124-340
  • Description: CRUM Market Fail ALL Although the CRUM Destination Value that is stored in the 3 locations are matched, their values are not set (0).
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Replace the MCU PWB.
  • Code: 124-341, 124-351, 124-361
  • Description: • 124-341: One of CRUM destinations is different from the others (IOT). • 124-351: One of CRUM OEM destinations is different from the others (IOT). • 124-361: One of CRUM Enable/Disable settings is different from the others (IOT).
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings, SYS 1. 2. If the problem persists, replace the MCU PWB.
  • Code: 124-342, 124-352, 124-362
  • Description: CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM Enabled/ Disabled that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • 124-342: One of CRUM destinations is different from the others (SYS 1). • 124-352: One of CRUM OEM destinations is different from the others (SYS 1). • 124-362: One of CRUM Enable/Disable settings is different from the others (SYS 1).
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings, MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-343, 124-353, 124-363
  • Description: CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM Enabled/Disabled that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • 124-343: One of CRUM destinations is different from the others (SYS 2). • 124-353: One of CRUM OEM destinations is different from the others (SYS 2). • 124-363: One of CRUM Enable/Disable settings is different from the others (SYS 2).
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings, SYS 2. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-344, 124-346
  • Description: Billing error has occurred due to one of the following problems. • The Billing Meter Types that are stored in multiple locations are all different. • The Billing Count Types that are stored in multiple locations are all different. • 124-344: Billing Meter Type Fail (different at all 3 locations) • 124-346: Billing Count Type Fail (different at all 3 locations)
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-345
  • Description: Billing Meter Type Restoration Fail When at least one Billing Meter Type is not matched and the machine automatic correction has failed to correct the problem.
  • Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC131 NVM Read/ Write to compare the following NVM values. • If the values of 720-002 and 720-062 are the same, replace the MCU PWB. • If the values are different, replace the I/P PWB PWB).
  • Code: 124-347
  • Description: Billing Count Type Restoration Fail When at least one Billing Count Type is not matched and the machine automatic correction has failed to correct the problem.
  • Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC131 NVM Read/ Write to compare the following NVM values. • If the values of 720-052 and 720-063 are the same, replace the MCU PWB. • If the values are different, replace the I/P PWB PWB).
  • Code: 124-348
  • Description: All Model Break Points Mismatch The Model Break Points that are stored in multiple locations are all different.
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-349
  • Description: Model Break Point Restoration Fail When at least one Model Break Point is not matched and the machine automatic correction has failed to correct the problem.
  • Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC131 NVM Read/ Write to compare the following NVM values. • If the values of 720-057 and 720-064 are the same, replace the MCU PWB. • If the values are different, replace the I/P PWB PWB).
  • Code: 124-350
  • Description: CRUM OEM Fail All Although the CRUM OEM Destination that is stored in the 3 locations are matched, their values are not set (0).
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Replace the MCU PWB.
  • Code: 124-360
  • Description: CRUM Validation/ 124-390 CRUM OEM Fail All CRUM error has occurred due to one of the following problems. • Although the CRUM Enabled/ Disabled that is stored in the 3 locations are matched, their values are not set (0). • Although the CRUM OEM Destination that is stored in the 3 locations are matched, their values are not set (0) • 124-360: All three CRUM Enable/ Disable settings are not set (0 or different values are set). • 124-390: All three CRUM OEM destinations are not set (0 or different values are set). #Case-(2)
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Replace the MCU PWB.
  • Code: 124-380
  • Description: CRUM Market Fail All (2) Although the CRUM Destination Value that is stored in the 3 locations are matched, their values are not set (0).
  • Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-381
  • Description: CRUM Market/ 124-391 CRUM OEM Fail MCU CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the MCU PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the MCU PWB do not match).
  • Causes: • MCU PWB, PL 12.1.15
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings, SYS 1. 2. If the problem persists, replace the MCU PWB.
  • Code: 124-382, 124-392
  • Description: CRUM Market/ CRUM OEM Fail SYS 1 (2) CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match) • 124-382: One of CRUM destinations is different from the others (SYS 1). #Case-(2) • 124-392: One of CRUM OEM destinations is different from the others (SYS 1). #Case-(2)
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings, MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 124-383, 124-393
  • Description: CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match).
  • Causes: • I/P PWB, PL 12.4.1
  • Troubleshooting Guides: 1. Perform DC132 Machine Serial Number Settings, SYS 2. 2. If the problem persists, replace the I/P PWB PWB).
  • Code: 202-399
  • Description: Timer Internal Fail The System Data = 700-124 (Auto Clear Timer (Combining Auto Resume Timer, Auditron Off Timer and Tools Off Timer)) settings value was detected to be from 1 to 29 in an MF device. This failure does not occur in Prt machines for values of 1 to 29.
  • Causes:
  • Troubleshooting Guides: 1. Check the System Data = 700-124 (Auto Clear Timer, Auto Resume Timer, Auditron Off Timer and Tools Off Timer) value. This failure will occur when values of 1 to 29 is set in the MF device. • Other than 700-124, this failure may also occur when any timer-related System Data settings value is changed. In that case, check the corresponding System Data for the correct value. 2. If the problem persists, go to Common System Fail.


– Get more error code list with quick guide to fix printer product, click here


– About get help with reseting Epson inkpad or others, click here

– Get more information about Epson XP 15000 troubleshooting, click here

Xerox printer reset software introduction:

Notes before resetting Xerox printer:

– Identify accurate version, serial and crum of Xerox printer.
– How to get Xerox printer model info: Click Here
– Before you continue with the reprogramming of the firmware, please make sure that the device is installed on your computer.
It is very important that under no circumstances should you remove the chip from the cartridge while reprogramming the firmware. After you have succesfully reprogrammed the printer, remove the chip from the cartridge and store it somewhere safely (the chip – a key). In all cartridges which you are going to use in the printer, the chip has to be either removed or sealed. If you have accidently inserted a new cartridge without removing the chip, the device will be blocked. In order to unblock it, you can use the stored chip as a key which help you to unblock the printer.
– And make sure that any other devices (except mouse and keyboard), which are connected to your computer via USB or LPT ports are disconnected. It’s preferable that the computer is connected to the “UPS” (uninterruptible power source) device, because if during the reprogramming process the electricity source has any interruptions, then the reprogramming will be carried out with an error, which makes the device unable to work.
– This firmware will be installed directly to your printer. Before opening firmare link make sure that printer is turned on and connected to your computer and printer drivers are installed correctly.
Be aware that with the reprogramming of the firmware the manufacturer’s warranty goes lost!!

How To Run Firmware Fix Xerox printer

1. Connect the printer to the computer and turn it on.
2. Wait until the printer is ready for work.
3. Drag and drop *.hd to usbprns2.exe file.

Run Firmware Fix Xerox B205

4. The reprogramming process starts automatically.
5. Wait until the printer reprograms (10-20 minute) and restarts.
6. After that the reprogramming process is finished, restart the printer.
– Fix Xerox B205 Toner Empty Error, click here

Contact us to get support with Xerox Phaser 7100 Error case

Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.

BSD-ON:

BSD 10.1 — Fusing Heat Control

After the Main Lamp turned On during warm up, the Control Thermistor did not detect

READY temperature within the specified time.

After the Main Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the empty rotation started, the Control Thermistor did not detect the empty rotation

finishing temperature within the specified time.

After the Main Lamp turned On during printing, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during printing, the Control Thermistor did not detect a spe-

cific temperature within the specified time.

Initial Actions

Voltage Supply

Indoor Temperature

Procedure

NOTE: When this fault occurs, NVM location 744-005 is set to 1, 2, or 3, depending on the

fault. You must reset this location to 0 in order to clear the fault.

Check for paper on the Fuser. The Fuser has no paper wrapped round it.

Y

N

Remove the paper.

Check the installation of the Fuser Unit. The Fuser Unit is securely installed.

Y

N

Install the Fuser Unit securely.

Remove the Fuser Unit. Check the conductivity of the contact points of the Thermostat. The

contact points are connected.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Main Lamp between J621-6 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Main Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Sub Lamp between J621-2 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Sub Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Control (Center) Thermistor between J621-5 and J621-1

10.1). There is no open circuit in the Center STS and the resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

(PL

7.1).

A

Initial Issue

WorkCentre 5335 Family Service Documentation

A

Check the resistance of the Rear Thermistor between J621-7 and J621-3

resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

Check the wire between P/J411-B7 and J621-7 for an open circuit or a short circuit (

10.1). The wire between

short circuit.

Y

N

Repair the open circuit or short circuit.

Check the wire between

The wire between

Y

N

Repair the open circuit or short circuit.

Replace the Fuser Unit

If the problem persists, replace the MCU PWB

(BSD

07/2011

2-83

BUS Updated 12/2011

(PL

7.1).

P/J411

and

J621

is conducting without an open circuit or a

P/J414

and

P530

for an open circuit or a short circuit

P/J414

and

P530

conducts and if free of a short circuit.

(PL

7.1). If the problem persists, replace the AC Drive PWB

(PL

18.2).

(BSD

10.1). The

BSD

(BSD

10.1).

(PL

18.2)

Status Indicator RAPs

010-338

BSD-ON:

BSD 10.1 — Fusing Heat Control

After the Main Lamp turned On during warm up, the Control Thermistor did not detect

READY temperature within the specified time.

After the Main Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the empty rotation started, the Control Thermistor did not detect the empty rotation

finishing temperature within the specified time.

After the Main Lamp turned On during printing, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during printing, the Control Thermistor did not detect a spe-

cific temperature within the specified time.

Initial Actions

Voltage Supply

Indoor Temperature

Procedure

NOTE: When this fault occurs, NVM location 744-005 is set to 1, 2, or 3, depending on the

fault. You must reset this location to 0 in order to clear the fault.

Check for paper on the Fuser. The Fuser has no paper wrapped round it.

Y

N

Remove the paper.

Check the installation of the Fuser Unit. The Fuser Unit is securely installed.

Y

N

Install the Fuser Unit securely.

Remove the Fuser Unit. Check the conductivity of the contact points of the Thermostat. The

contact points are connected.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Main Lamp between J621-6 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Main Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Sub Lamp between J621-2 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Sub Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Control (Center) Thermistor between J621-5 and J621-1

10.1). There is no open circuit in the Center STS and the resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

(PL

7.1).

A

Initial Issue

WorkCentre 5335 Family Service Documentation

A

Check the resistance of the Rear Thermistor between J621-7 and J621-3

resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

Check the wire between P/J411-B7 and J621-7 for an open circuit or a short circuit (

10.1). The wire between

short circuit.

Y

N

Repair the open circuit or short circuit.

Check the wire between

The wire between

Y

N

Repair the open circuit or short circuit.

Replace the Fuser Unit

If the problem persists, replace the MCU PWB

(BSD

07/2011

2-83

BUS Updated 12/2011

(PL

7.1).

P/J411

and

J621

is conducting without an open circuit or a

P/J414

and

P530

for an open circuit or a short circuit

P/J414

and

P530

conducts and if free of a short circuit.

(PL

7.1). If the problem persists, replace the AC Drive PWB

(PL

18.2).

(BSD

10.1). The

BSD

(BSD

10.1).

(PL

18.2)

Status Indicator RAPs

010-338

background image

Коды неисправностей

При сбое во время печати или неисправности аппарата на экран выводится код
неисправности. Если на экране отображается код неисправности, которого нет в
таблице ниже, или неисправность не удается устранить, выполнив указанные далее
действия, обратитесь в сервисный центр Xerox. При отображении кода
неисправности сбрасываются все данные печати на аппарате, а также данные в
его встроенной памяти.

Рекомендуемое решение

Вероятная причина

Код неисправности

Откройте передние дверцы и
убедитесь, что дверца
фьюзера закрыта.
Выключите и снова включите
аппарат.

Выдвижная секция фьюзера
открыта

010 300

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибки скорости ремня
фьюзера

010 310, 010 311, 010 312,

010 313, 010 314, 010 315,
010 316, 010 317, 010 318,

010 319, 010 321, 010 323,

010 324, 010 325, 010 326,

010 327, 010 328, 010 333,

010 334, 010 335, 010 336,

010 337, 010 338, 010 341,

010 342, 010 343, 010 344,

010 347, 010 348, 010 349,

010 350, 010 351, 010 352,

010 353, 010 354, 010 355,

010 356, 010 357, 010 369,

010 370, 010 371, 010 374,

010 379, 010 380, 010 386,

010 387, 010 389

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибка температуры
фьюзера или фьюзер
отключен

010 360, 010 401

10-25

Печатная машина Xerox

®

Color 800/1000

Руководство пользователя

Устранение неисправностей

Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.

ainur101

Сообщения: 15
Стаж: 1 год
Поблагодарили: 1 раз

Репутация:

Xerox B405 ошибка 010-105

Сообщение

ainur101 » 19 апр 2022, 13:56

Пришел Xerox Versalink B405 с кучей ошибок (просил переустановить черный картридж, не пускал в админку, ругался на открытую заднюю крышку). Установил новый блок фотобарабана + новый тонер картридж, отрегулировал лапку концевика задней крышки, сделал factory reset и восстановил доступ к админке. Но печатать так и не захотел, вернее застревает бумага не доходя до фьюзера, с ошибкой 010-105(После включения регистрационной муфты датчик выхода не активируется бумагой в течение указанного времени)

Может кто то сталкивался?

Аватара пользователя

DJON

Сообщения: 151
Стаж: 1 год 1 месяц
Благодарил (а): 3 раза
Поблагодарили: 9 раз

Репутация:

Xerox B405 ошибка 010-105

Сообщение

DJON » 23 дек 2022, 14:16

Доброго всем! Всех с предновогодней тяпницей! Такая же ситуация и у меня! Пробег аппарата чуть больше 155к. Поменял всё в печке ,ЗИП СЕТовский. Запустил отпечатал несколько листов нормально и двухсторонних тоже! Потом застрял,вытащил бумагу он отпечатал нормально.И после этого ни в какую! :blya Тестируется при включении нормально,входит в готовность! Но при печати лист останавливается в печке,зайдя на 1 см.И получаем 010-105. Датчик выхода рабочий,если его заблокировать аппарат сразу вываливается в эту ошибку. Датчик регистрации тоже рабочий,проверил. Короче я в ступоре! Все флажки работают нормально! Печка останавливается как только лист в неё входит,ролики протяжки крутят и лист собирается перед печкой. Не весь, имеем пару гармошек и конец листа останавливается на флажке регистрации. :blya :blya :blya Мысли кончились! :fix Помогайте, спасибо! :drink1

Аватара пользователя

DJON

Сообщения: 151
Стаж: 1 год 1 месяц
Благодарил (а): 3 раза
Поблагодарили: 9 раз

Репутация:

Xerox B405 ошибка 010-105

Сообщение

DJON » 23 дек 2022, 15:29

Уже раз пять разбирал собирал! И заливал всё смазкой аж текло, и на сухо вытирал и собирал, и старую тканевую накладку поставил ( она закрывает полностью планку , а СЕТовская не доходила до края 0,5 мм) ! Собрать по другому там не возможно , не встанет в пазы ничего — попробовал! Всё крутиться вручную отлично!!! Значит буду ждать донора!

Аватара пользователя

takoy

Сообщения: 79
Стаж: 1 год 1 месяц
Благодарил (а): 2 раза
Поблагодарили: 4 раза

Репутация:

Аватара пользователя

DJON

Сообщения: 151
Стаж: 1 год 1 месяц
Благодарил (а): 3 раза
Поблагодарили: 9 раз

Репутация:

Xerox B405 ошибка 010-105

Сообщение

DJON » 26 дек 2022, 10:33

Доброго! Ничего такого что там описано! В пятницу уже вечером догнал в чём дело! На холодную (вручную) печь тянет лист, ставишь в аппарат ,тестируется,но при печати сразу получаем остановку в печке! Вытащил печку горячую и стал крутить, лист стоит на месте!!!! Короче , сегодня подложил под пружины прокладки, увеличил растяжение пружин на 3 мм. На обум, меньше не получилось!!! И на те вам всё работает, прогнал уже 120 двухстронних и ни одного замятия!!! Скорее всего у меня брак самой печки ,а именно пружин! Хотя я их снимал/ставил раз 20-ть!!! :drink1

Аватара пользователя

DJON

Сообщения: 151
Стаж: 1 год 1 месяц
Благодарил (а): 3 раза
Поблагодарили: 9 раз

Репутация:

Xerox B405 ошибка 010-105

Сообщение

DJON » 27 дек 2022, 15:44

9999 писал(а): ↑27 дек 2022, 11:07

DJON писал(а): ↑26 дек 2022, 10:33
брак самой печки ,а именно пружин!

Типа сели?

Ну не знаю как это называется, выше всё описал! На холодную всё ок, на горячую не крутит термоплёнку! Ничего другого не нашёл как подложить под пружины и всё заработало! Посмотрим сколько отработает!

  • 0 Ответы
    192 Просмотры
    Последнее сообщение

    Я поленился установить аватар

    07 июн 2022, 15:04

  • 2 Ответы
    339 Просмотры
    Последнее сообщение

    Аватара пользователя

    03 июн 2022, 03:49

  • 1 Ответы
    166 Просмотры
    Последнее сообщение

    Аватара пользователя

    02 июн 2022, 13:53

  • 4 Ответы
    239 Просмотры
    Последнее сообщение

    Аватара пользователя

    26 сен 2022, 09:56

  • 0 Ответы
    104 Просмотры
    Последнее сообщение

    Я поленился установить аватар

    05 дек 2022, 09:08

Перейти к контенту

Ошибка 016-910 на принтерах Xerox Versalink различных модификаций возникает по причине того, что в лотке отсутствует бумага, совместимая с заданными спецификациями печати.

Кастомизация включает следующие возможности:

настройка типа бумаги xerox versalink

Таким образом, бумага загруженная в лоток подачи должна соответствовать выбранным настройкам. Если принтер определит несоответствие, ошибка 016-910 появится вновь.

Проблема чтения PDF-файла

Слипшиеся листы

лоток с бумагой xerox

Выньте бумагу из лотка, оставьте в проветриваемом помещении на несколько часов с целью сушки. Затем возьмите стопку с одной стороны и несколько раз потрясите. Обсохнувшие носители верните в лоток, правильно отрегулировав направляющие длины и ширины.

1 комментарий

Ничего не помогло…
Немного потыкав, видимо это у меня генетическое… нашел решение.
Заходим в принтеры, жмем на наш ксерокс, управление, далее свойство принтера
Находим вкладку порты, жмем добавить порт, далее, tcp/ip, прописываем адрес, в моем случае 192.168.1.41 — галочку на только что добавленном порте и применяем.
Пробная печать — Профит

Источники:

https://tonerdrug. ru/oshibka-016-910-na-printerach-xerox-versalink/

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

Понравилась статья? Поделить с друзьями:
  • Xerox 7025 ошибка 024 965
  • Xerox 700 ошибка 10 321
  • Xerox 700 ошибка 042 328
  • Xerox 700 коды ошибок
  • Xerox 6605 ошибка 092 672