xerox 700 fault 010-321
good day gents, just replaced my esspwb on my 700, got past a few errors, cleared them up, now whenever i try to print i am getting 010-321. i can hear the machine start to try print, but jams and this comes up. i took fuser out, changed, still same error, i have read somewhere that resetting NVM 744-350 to 0 works on the xerox 250, but don’t want to try it on this machine as i am not sure it’s the same nvm for the 700. any suggestions? thanks
-
03-03-2015
#2
Senior Tech
100+ Posts
- Rep Power
- 0
Re: xerox 700 fault 010-321
DC700 edoc says check fuser nip sensor, (actuator broken) and in UI diagnostics, 010-203 for hi/low change when actuating sensor. Could be one way clutch, gear drive, or fuser not pushed in all the way.
-
03-03-2015
#3
Re: xerox 700 fault 010-321
IF you are going to repair these type of machine, then you need the service manual. If you had this from day1 you would have been up and running long time ago.
-
03-03-2015
#4
Senior Tech
100+ Posts
- Rep Power
- 0
Re: xerox 700 fault 010-321
I agree, but most people that come to this forum are not technicians, mainly owners of small shops that try to maintain their own machines. Most Xerox machines have no hard copy service manuals. A PWS laptop with edoc service documentation is cost prohibitive for most owners/operators with only one machine.
-
03-03-2015
#5
Senior Tech
100+ Posts
- Rep Power
- 19
Re: xerox 700 fault 010-321
Originally Posted by xtrain
I agree, but most people that come to this forum are not technicians, mainly owners of small shops that try to maintain their own machines. Most Xerox machines have no hard copy service manuals. A PWS laptop with edoc service documentation is cost prohibitive for most owners/operators with only one machine.
thanks i will invest in one shortly, but as this problem came by suprise (like all problems) and xerox do not service machines they didn’t sell here in the bahamas, and trying to get a tech to see you on the side is next to impossible im stuck trying to get this machine up myself and with the help of good guys like you all to try get it back up and running. thanks all for the assistance.
-
03-03-2015
#6
Senior Tech
250+ Posts
- Rep Power
- 33
Re: xerox 700 fault 010-321
Fly me out to the Bahamas and I’ll fix your machine…lol I’ll even upgrade to 700i and get it running perfectly.
-
03-03-2015
#7
Senior Tech
100+ Posts
- Rep Power
- 0
Re: xerox 700 fault 010-321
Hi Milo, long time. I worked on Xerox machines in Nassua Bahamas ,two trips, two weeks at a time. Hard to get parts shipped on a boat from Florida. Atlantis was fun to work at, but driving on the left side was like when I was in England, hard to get used to. The people are real pleasant to work with. You would really like it.
-
03-03-2015
#8
Senior Tech
100+ Posts
- Rep Power
- 19
Re: xerox 700 fault 010-321
Originally Posted by Milo Wilson
Fly me out to the Bahamas and I’ll fix your machine…lol I’ll even upgrade to 700i and get it running perfectly.
hell if you serious i would, need this repaired asap. need software on the 700, my software version is saying 0.0.0.0 after i did the switch of board and cleared everything.
-
03-03-2015
#9
Senior Tech
250+ Posts
- Rep Power
- 33
Re: xerox 700 fault 010-321
I am serious. My phone number: 714-292-6912
-
03-04-2015
#10
Re: xerox 700 fault 010-321
Originally Posted by xtrain
I agree, but most people that come to this forum are not technicians, mainly owners of small shops that try to maintain their own machines. Most Xerox machines have no hard copy service manuals. A PWS laptop with edoc service documentation is cost prohibitive for most owners/operators with only one machine.
I hear you. This is a new post for this same problem, read the previous post on this same problem machine. I guess, what i am saying, is this type of machine has a lot of adjustments that a tech must have in his tools for know-hows, otherwise he will be back and forth a lot or a lot of costly errors can occur.
Last edited by subaro; 03-04-2015 at 02:01 AM.
Bookmarks
Bookmarks
Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
- BB code is On
- Smilies are On
- [IMG] code is On
- [VIDEO] code is On
- HTML code is Off
Forum Rules
-
Does anyone have any clue what this might mean?
The paper is getting jammed before the fuser because of this error message.
-
This could mean that the clip sensor on your fuser unit was dislodged.
this is normally caused by ejecting a jammed feed in a reversed direction
(jammed feed should be removed along the paper path which is the direction going out of the fuser.. to the right, and not the opposite direction no matter how small the paper travel that went into the fuser unit)
If service call takes a long time, you can fix this. there are a few screws on the bottom of the fusing unit, but to be sure just peek through the middle part near the bottom side of the fusing unit on the side where the paper enters, there should be a black clip that will appear not straight (which shows it got out of place, hence no papaer can go through it.) you can just open the fusing unit from below and reposition this clip, and it should start printing.Regards.
Коды неисправностей
При сбое во время печати или неисправности аппарата на экран выводится код
неисправности. Если на экране отображается код неисправности, которого нет в
таблице ниже, или неисправность не удается устранить, выполнив указанные далее
действия, обратитесь в сервисный центр Xerox. При отображении кода
неисправности сбрасываются все данные печати на аппарате, а также данные в
его встроенной памяти.
Рекомендуемое решение
Вероятная причина
Код неисправности
Откройте передние дверцы и
убедитесь, что дверца
фьюзера закрыта.
Выключите и снова включите
аппарат.
Выдвижная секция фьюзера
открыта
010 300
Выключите и снова включите
аппарат.
Если неисправность
устранить не удается,
обратитесь в сервисный
центр.
Ошибки скорости ремня
фьюзера
010 310, 010 311, 010 312,
010 313, 010 314, 010 315,
010 316, 010 317, 010 318,
010 319, 010 321, 010 323,
010 324, 010 325, 010 326,
010 327, 010 328, 010 333,
010 334, 010 335, 010 336,
010 337, 010 338, 010 341,
010 342, 010 343, 010 344,
010 347, 010 348, 010 349,
010 350, 010 351, 010 352,
010 353, 010 354, 010 355,
010 356, 010 357, 010 369,
010 370, 010 371, 010 374,
010 379, 010 380, 010 386,
010 387, 010 389
Выключите и снова включите
аппарат.
Если неисправность
устранить не удается,
обратитесь в сервисный
центр.
Ошибка температуры
фьюзера или фьюзер
отключен
010 360, 010 401
10-25
Печатная машина Xerox
®
Color 800/1000
Руководство пользователя
Устранение неисправностей
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Dislikes: 0
-
03-03-2015
#1
Senior Tech
100+ Posts
- Rep Power
- 20
xerox 700 fault 010-321
good day gents, just replaced my esspwb on my 700, got past a few errors, cleared them up, now whenever i try to print i am getting 010-321. i can hear the machine start to try print, but jams and this comes up. i took fuser out, changed, still same error, i have read somewhere that resetting NVM 744-350 to 0 works on the xerox 250, but don’t want to try it on this machine as i am not sure it’s the same nvm for the 700. any suggestions? thanks
-
03-03-2015
#2
Senior Tech
100+ Posts
- Rep Power
- 0
Re: xerox 700 fault 010-321
DC700 edoc says check fuser nip sensor, (actuator broken) and in UI diagnostics, 010-203 for hi/low change when actuating sensor. Could be one way clutch, gear drive, or fuser not pushed in all the way.
-
03-03-2015
#3
Re: xerox 700 fault 010-321
IF you are going to repair these type of machine, then you need the service manual. If you had this from day1 you would have been up and running long time ago.
-
03-03-2015
#4
Senior Tech
100+ Posts
- Rep Power
- 0
Re: xerox 700 fault 010-321
I agree, but most people that come to this forum are not technicians, mainly owners of small shops that try to maintain their own machines. Most Xerox machines have no hard copy service manuals. A PWS laptop with edoc service documentation is cost prohibitive for most owners/operators with only one machine.
-
03-03-2015
#5
Senior Tech
100+ Posts
- Rep Power
- 20
Re: xerox 700 fault 010-321
Originally Posted by xtrain
I agree, but most people that come to this forum are not technicians, mainly owners of small shops that try to maintain their own machines. Most Xerox machines have no hard copy service manuals. A PWS laptop with edoc service documentation is cost prohibitive for most owners/operators with only one machine.
thanks i will invest in one shortly, but as this problem came by suprise (like all problems) and xerox do not service machines they didn’t sell here in the bahamas, and trying to get a tech to see you on the side is next to impossible im stuck trying to get this machine up myself and with the help of good guys like you all to try get it back up and running. thanks all for the assistance.
-
03-03-2015
#6
Senior Tech
250+ Posts
- Rep Power
- 34
Re: xerox 700 fault 010-321
Fly me out to the Bahamas and I’ll fix your machine…lol I’ll even upgrade to 700i and get it running perfectly.
-
03-03-2015
#7
Senior Tech
100+ Posts
- Rep Power
- 0
Re: xerox 700 fault 010-321
Hi Milo, long time. I worked on Xerox machines in Nassua Bahamas ,two trips, two weeks at a time. Hard to get parts shipped on a boat from Florida. Atlantis was fun to work at, but driving on the left side was like when I was in England, hard to get used to. The people are real pleasant to work with. You would really like it.
-
03-03-2015
#8
Senior Tech
100+ Posts
- Rep Power
- 20
Re: xerox 700 fault 010-321
Originally Posted by Milo Wilson
Fly me out to the Bahamas and I’ll fix your machine…lol I’ll even upgrade to 700i and get it running perfectly.
hell if you serious i would, need this repaired asap. need software on the 700, my software version is saying 0.0.0.0 after i did the switch of board and cleared everything.
-
03-03-2015
#9
Senior Tech
250+ Posts
- Rep Power
- 34
Re: xerox 700 fault 010-321
I am serious. My phone number: 714-292-6912
-
03-04-2015
#10
Re: xerox 700 fault 010-321
Originally Posted by xtrain
I agree, but most people that come to this forum are not technicians, mainly owners of small shops that try to maintain their own machines. Most Xerox machines have no hard copy service manuals. A PWS laptop with edoc service documentation is cost prohibitive for most owners/operators with only one machine.
I hear you. This is a new post for this same problem, read the previous post on this same problem machine. I guess, what i am saying, is this type of machine has a lot of adjustments that a tech must have in his tools for know-hows, otherwise he will be back and forth a lot or a lot of costly errors can occur.
Last edited by subaro; 03-04-2015 at 01:01 AM.
Bookmarks
Bookmarks
Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
- BB code is On
- Smilies are On
- [IMG] code is On
- [VIDEO] code is On
- HTML code is Off
Forum Rules
-
Does anyone have any clue what this might mean?
The paper is getting jammed before the fuser because of this error message.
-
This could mean that the clip sensor on your fuser unit was dislodged.
this is normally caused by ejecting a jammed feed in a reversed direction
(jammed feed should be removed along the paper path which is the direction going out of the fuser.. to the right, and not the opposite direction no matter how small the paper travel that went into the fuser unit)
If service call takes a long time, you can fix this. there are a few screws on the bottom of the fusing unit, but to be sure just peek through the middle part near the bottom side of the fusing unit on the side where the paper enters, there should be a black clip that will appear not straight (which shows it got out of place, hence no papaer can go through it.) you can just open the fusing unit from below and reposition this clip, and it should start printing.Regards.
Коды неисправностей
При сбое во время печати или неисправности аппарата на экран выводится код
неисправности. Если на экране отображается код неисправности, которого нет в
таблице ниже, или неисправность не удается устранить, выполнив указанные далее
действия, обратитесь в сервисный центр Xerox. При отображении кода
неисправности сбрасываются все данные печати на аппарате, а также данные в
его встроенной памяти.
Рекомендуемое решение
Вероятная причина
Код неисправности
Откройте передние дверцы и
убедитесь, что дверца
фьюзера закрыта.
Выключите и снова включите
аппарат.
Выдвижная секция фьюзера
открыта
010 300
Выключите и снова включите
аппарат.
Если неисправность
устранить не удается,
обратитесь в сервисный
центр.
Ошибки скорости ремня
фьюзера
010 310, 010 311, 010 312,
010 313, 010 314, 010 315,
010 316, 010 317, 010 318,
010 319, 010 321, 010 323,
010 324, 010 325, 010 326,
010 327, 010 328, 010 333,
010 334, 010 335, 010 336,
010 337, 010 338, 010 341,
010 342, 010 343, 010 344,
010 347, 010 348, 010 349,
010 350, 010 351, 010 352,
010 353, 010 354, 010 355,
010 356, 010 357, 010 369,
010 370, 010 371, 010 374,
010 379, 010 380, 010 386,
010 387, 010 389
Выключите и снова включите
аппарат.
Если неисправность
устранить не удается,
обратитесь в сервисный
центр.
Ошибка температуры
фьюзера или фьюзер
отключен
010 360, 010 401
10-25
Печатная машина Xerox
®
Color 800/1000
Руководство пользователя
Устранение неисправностей
Fault Code:
Description / Notes:
002-770
The Hard Drive (HDD)
is over capacity
003-xxx codes
Generally:
Communication Errors between boards in the machine
005-xxx codes
Generally: Document
Feeder problems
005-121 thru 005-158
Document Jams
005-194 thru 005-199
Document size mismatch
problems
005-275/280
Document Feeder
communication errors
005-281 thru 005-283
Document Tray lift
problems
005-284
Document APS (Automatic
Paper Sensors) failure (there are 3 sensors which detect various paper widths
on the Document Feeder)
005-285
Document Nudger up
failure
005-286
Document feed-out
sensor failure
005-303
Document Tray
Interlock is open
005-304
Document Platen
Interlock opened during a job
005-305
Document Top Cover
Interlock opened during a job
005-306
Document Tray
Interlock opened during a job
005-308/309
Document Left Cover is
open or opened during a job
005-906 thru 005-918
Document is still
detected in feeder after power-on or after closing one of the document door
interlocks
010-xxx codes
Generally: Fuser
faults
010-311
Open Fuser Thermistor
was detected (white connector)
010-319 *
Fuser Heat Control
problem *NOTE: This code must be cleared from Diagnostic Mode… details below.
010-320 **
Fuser Overheat
problem… (can be reported by any of the 3 thermistors in the fuser) ** NOTE:
This code must be cleared from Diagnostic Mode… details below.
010-322 thru 010-323
Fuser Thermistor open
circuit detected (NCCenter Sensor or Rear Thermistor)
010-324***
Fuser NVM (Memory)
failure *** NOTE: This code must be cleared from Diagnostic Mode… details below.
010-326 thru 010-327
Fuser Heat Control
problems
010-330
Fuser Motor failure
010-420
Fuser Module nearing
end of life… NOTE: Read below for fuser count reset info.
010-421
Fuser Module «End
of Life»… NOTE: If the fuser is still good, you can replace the Fuser
Reset Fuse (on top of the fuser) and possibly the Fuser Heat Roll to keep it
running.
012-xxx codes
Generally: Finisher
problems
013-xxx codes
Generally: Finisher /
Booklet Maker problems
016-xxx codes
Generally: Options or
Software failures
016-311
Scanner not detected
024-340 thru 024-747
ESS (Network
Controller) problems
024-910 thru 024-917
Paper size Sensing
problems (in one of the paper drawers)
024-919
Face Up Tray interlock
open
024-920/922
Face Down Tray 1 full
/ Face Down Tray 2 full
024-923/924/ 925
Toner Cartridge Empty
— Y / M / C
024-927/930
OCT (Offset Catch
Tray) full / Stacker Tray full
024-934 thru 024-939
Paper type mismatch
errors
024-946/947/ 948/949
Tray not in position
(T1/2/3/4)
024-950/951/
952/953/954/ 955/956
No Paper in tray
(T1/2/3/4/5/6/7)
042-313
Rear Fuser Cooling Fan
failure
042-320/321/ 322/323
Drum Motor failures —
320=Y, 321=C, 322=M, 323=K (black)
042-324
IBT Belt Drive Motor
failure
042-325
Main Motor failure
042-326
IBT Belt Home position
not detected in time
042-327
IBT Belt Position
failure
042-328
IBT Belt Edge Sensor
failure
042-330
Fuser Exhaust Fan
failure
042-331
Blower Motor Fan
failure
042-600/601/ 602
Belt Edge timing
failures
042-603
Suction Filter end of
life
045-xxx codes
Printing communication
failures
061-320/321
ROS (Laser Unit)
polygon motor failures
061-323 thru 061-607
ROS (Laser Unit)
problems
062-357
CCD (Scanner) Fan
failure
062-360
Exposure Carriage
position failure.
062-371
Exposure Lamp not
lighting (or very dim)
071-101 thru 071-105
Paper Jams from Tray 1
at takeaway or registration
071-210
Tray 1 Lift failure
072-101 thru 072-105
Paper jams from Tray 2
at takeaway or registration
072-210
Tray 2 Lift failure
073-101 thru 073-105
Paper jam from Tray 3
at takeaway or registration
073-210
Tray 3 Lift failure
074-101 thru 074-105
Paper jam from Tray 4
at takeaway or registration
074-210
Tray 4 Lift failure
075-100 thru 075-135
Paper jam from Tray 5
at takeaway or registration
075-210/211
Tray 5 Lift failure /
Lift down failure
077-103 thru 077-118
Fuser Exit Sensor jam
or final Exit Sensor jam.
077-120
Post 2nd BTR Roll
Sensor jam
077-123 thru 077-130
Inverter jams
077-300
Front Cover interlock
open
077-301
Left Door interlock
open
077-302
Right Cover interlock
open
077-303
Transfer Module 2
interlock open
077-909
Paper detected in
paper path at power-on
078-100 thru 078-151
Paper jam from Tray 6
/ High Capacity Feeder (HCF) at takeaway or registration
078-250
Tray 6 (HCF) Lift
failure
078-300
HCF (Hi Capacity
Feeder) Top Cover interlock open
078-301
HCF Docking Interlock
open
089-600 thru 089-617
Image Registration
Control problems
091-311
BCR and Black Charge
Corotron Cleaner control problem
091-312
Black Charge /
Preclean HVPS (Hi Volt Power Supply) failure
091-313
Drum Cartridge CRUM
(chip) communication failure
091-320
Black Charge Corona
Wire is broken
091-400
Waste Toner Bottle
replacement needed soon
091-401
Black Drum Cartridge
near end of life
091-403
Black Charge Corotron
Assembly near end of life
091-404
Black Charge Corotron
Assembly has reached end of life
091-411
Yellow Drum Cartridge
near end of life
091-421
Magenta Drum Cartridge
near end of life
091-431
Cyan Drum Cartridge
near end of life
091-910
Waste Toner Bottle not
detected
091-911
Waste Toner Bottle
full
091-913
Black Drum Cartridge
at end of life
091-914 thru 091-916
or 091-921
Black Drum Cartridge
CRUM communication problems
091-917/920/924/925/927
Yellow Drum Cartridge
CRUM communication problems
091-918/922/ 928
Magenta Drum Cartridge
CRUM communication problems
091-919/923/ 926/929
Cyan Drum Cartridge
CRUM communication problems
091-932
Yellow Drum Cartridge
end of life
091-933
Magenta Drum Cartridge
end of life
091-934
Cyan Drum Cartridge
end of life
092-649/650
ADC Sensor Shutter
failures
092-651/652
IBT Belt ADC Sensor
(MOB ADC) failures
092-653 thru 092-660
ATC (from Developer
Unit) problems…653/657=yellow, 654/658=magenta, 655/659=cyan, 656/660=black
093-300
Marking Drawer
Interlock open
093-313 thru 093-317
Toner Dispense
problems… 314=Y, 315=M, 316=C, 317=K (black)
093-320
Developer Motor
failure
093-421 thru 093-425
Toner Cartridges low
421/422=K(black), 423=Y, 424=M, 425=C
093-600 thru 093-912
Toner Dispense
problems (600=Y, 601=M, 602=C, 603/912=K(Black),
093-918 thru
Toner CRUM failures
(918/924 /925/926/936/ 940=K(black),927/933/937 =Y, 928/934/938 = M ,
929/935/939=C
093-940
094-320/321
1st BTR (Transfer
Roll) retract or contact problems
094-322/323
2nd BTR (Transfer
Roll) retract or contact problems
102-xxx codes
Generally: Network
Controller (ESS) problems
112-700
Finisher Punch Dust
Box full (hole punch bin)
116-xxx codes
Generally: Network
Controller (ESS) problems
123-xxx codes
Generally: UI (control
panel) faults
124-xxx codes
Generally:
Configuration errors (e.g., serial number disagreement between various boards
or machine speed errors, etc)
127-xxx codes
Printing failures
The A system error has occurred 010-321 code of fuser unit, usually, fuser nip fail. First of all, check if there any obstructions inside the printer.
Xerox Colour 550 System Error code 010-321
Solve
Fault code 010-321 Solutions on Xerox Colour 550 |
Here in this post, I’m explaining How to fix the error A system error has occurred 010-321 in your Xerox colour 550 series copier. If your machine is under maintenance you should call them to have it replaced. This introduction will help you to troubleshoot the common error 010-321 on your Xerox colour 550, Xerox 250, Xerox 240, Xerox 252, Xerox 260, Xerox 7765, Xerox 7775 models. We are sharing few methods to fix the error, so check them one by one until it gets solved.
Fix 010-321 error code
The A system error has occurred 010-321 code of fuser unit, usually, fuser nip fail. First of all, check if there any obstructions inside the printer. The fuser has a nvm and you want to reset it. Then follow these steps.
- Press and hold the zero (0) button for 5 seconds.
- Then press the start button and dial the password 654321 and confirm it.
- After this, you have to press the key button/log out button.
- Then go to system settings, common settings, maintenance or diagnostic.
- Then we will go to nvm read/write. Press 74435 on the chain link. Dial “0” on the new value column.
- Then save and confirm it. Close it. Press the exit button. The machine will restart itself and code will be gone out.
If the problem persists
- remove and reinstall the fuser unit.
- Check the fuser connector.
- Replace the fuser unit.
Find out the reason behind this error code in your copier, then replace that spare. If the problem persists again, it is better to call a Sharp Technician.
I hope this was helpful, don’t forget to share it via any of the share buttons on this page are highly welcomed as well.