Xerox 5330 ошибка 005 123

005-123 DADF Simplex/Side 1 Registration Sensor On Jam RAP

BSD-ON: BSD 5.6 Document Scan, Invert and Exit Transportation

005-123 The DADF registration sensor does not turn on within the specified time after the DADF pre registration sensor on.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.
• GP 8 How to Check a Solenoid or Clutch.

Perform the steps that follow:

1. Check for a foreign substance in the document path.
2. Check the surface of the takeaway roll and registration roll for foreign substances or wear. Clean or install new components as necessary, PL 5.50.
3. Enter dC330, code 005-110. Check the DADF registration sensor, PL 5.70 Item 3.
4. Enter dC330, code 005-206. Check the DADF pre registration sensor, PL 5.70 Item 3.
5. Enter dC330, code 005-098. Check the DADF takeaway clutch, (W/O TAG 002, PL 5.35 Item 2), (W/TAG 002, PL 5.36 Item 2).
6. Enter dC330, code 005-008. Check the DADF feed motor, PL 5.30 Item 3.
7. Check the drive gears, (W/OTAG 002, PL 5.35), (W/TAG 002, PL 5.36) for wear or damage. Install new components as necessary.
8. If the fault persists, install a new DADF PWB, PL 5.10 Item 11.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

Коды ошибок в Xerox 5330

A1-1 — A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 — E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 — E4-14 Exit jam
E3-6 Exit jam
E4-10 — E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 — E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 — E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 — U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 — U8-6 Problem with exposure lamp, lamp sensor, lamp board

The most common error codes.

Error
092-315 Description: ATC Fail RAP The frequency at which the ATC Average Fail or the ATC Amplitude Fail has been occurring has exceeded the threshold value. NOTE: • Although this Fault can be cleared by turning the power OFF and ON and it will be possible to out
062-396 Description: CCD Cable Connection Fail RAP A CCD Flat Cable connection error was detected.
024-912 Description: Tray 3 Size Mismatch RAP Operation Error. Size Mismatch Tray 3: Measured Length Mismatch. When the paper slow scan direction length is measured on the paper path, the length is different from the slow scan length for the size detected by the
005-940 Description: DADF No Original RAP Operation Fail. Final document correction notification due to DADF document being pulled out.
041-310 Description: IM Logic Fail RAP The IM (Image Management) software control error was detected.
092-315 Description: ATC Fail RAP The frequency at which the ATC Average Fail or the ATC Amplitude Fail has been occurring has exceeded the threshold value. NOTE: • Although this Fault can be cleared by turning the power OFF and ON and it will be possible to out
062-396 Description: CCD Cable Connection Fail RAP A CCD Flat Cable connection error was detected.
024-912 Description: Tray 3 Size Mismatch RAP Operation Error. Size Mismatch Tray 3: Measured Length Mismatch. When the paper slow scan direction length is measured on the paper path, the length is different from the slow scan length for the size detected by the
005-940 Description: DADF No Original RAP Operation Fail. Final document correction notification due to DADF document being pulled out.
041-310 Description: IM Logic Fail RAP The IM (Image Management) software control error was detected.

005-123 DADF Simplex/Side 1 Registration Sensor On Jam RAP

BSD-ON: BSD 5.6 Document Scan, Invert and Exit Transportation

005-123 The DADF registration sensor does not turn on within the specified time after the DADF pre registration sensor on.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.
• GP 8 How to Check a Solenoid or Clutch.

Perform the steps that follow:

1. Check for a foreign substance in the document path.
2. Check the surface of the takeaway roll and registration roll for foreign substances or wear. Clean or install new components as necessary, PL 5.50.
3. Enter dC330, code 005-110. Check the DADF registration sensor, PL 5.70 Item 3.
4. Enter dC330, code 005-206. Check the DADF pre registration sensor, PL 5.70 Item 3.
5. Enter dC330, code 005-098. Check the DADF takeaway clutch, (W/O TAG 002, PL 5.35 Item 2), (W/TAG 002, PL 5.36 Item 2).
6. Enter dC330, code 005-008. Check the DADF feed motor, PL 5.30 Item 3.
7. Check the drive gears, (W/OTAG 002, PL 5.35), (W/TAG 002, PL 5.36) for wear or damage. Install new components as necessary.
8. If the fault persists, install a new DADF PWB, PL 5.10 Item 11.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Видео #92 Замена девелопера Xerox WC 5325  5330  5335  5222  5225  5230  C118  123 | Phaser 5500 (автор: ЗаправкинЪ)25:14

#92 Замена девелопера Xerox WC 5325 5330 5335 5222 5225 5230 C118 123 | Phaser 5500

Видео Xerox WorkCentre 5335 Informational Video (автор: GWCopierSupplies)03:57

Xerox WorkCentre 5335 Informational Video

Видео Инструкция как разобрать Xerox Phaser 3250 (Чистка печки) (автор: Somas Service)22:46

Инструкция как разобрать Xerox Phaser 3250 (Чистка печки)

Видео dscf0376 - - xerox phaser 5335 xerox (автор: techlabsby)02:36

dscf0376 — — xerox phaser 5335 xerox

Видео Xerox Phaser 5335 Драйвер Windows 7 (автор: Pavel Vorobyov)03:17

Xerox Phaser 5335 Драйвер Windows 7

Видео Обзор принтера XEROX Phaser 3052NI (автор: APEKS)08:13

Обзор принтера XEROX Phaser 3052NI

Видео Ремонт поддона Xerox Phaser 5335 (автор: Николай Хазов)47:25

Ремонт поддона Xerox Phaser 5335

Видео dscf0376 xerox phaser 5335 xerox Low) (автор: Денис Шпаков)02:36

dscf0376 xerox phaser 5335 xerox Low)

6.6 Сообщения об ошибках и коды ошибок

131

Откройте лоток 2
Устраните застр.

затем
Откройте-закр. A

В принтере возникло застревание бумаги.
Выдвиньте наружу лоток 2 для поиска зоны застревания, и вытащите
застрявшую бумагу. Затем откройте и закройте переднюю крышку. Откройте
переднюю крышку, даже если под крышкой нет застрявшей бумаги. Ошибка на
дисплее не сбросится, пока вы не откроете и не закроете переднюю крышку.

См.
• «6.1 Устранение застревания бумаги» (стр. 113)

Откройте л.2 и 3
Устраните застр.

затем
Откройте-закр. A

В принтере возникло застревание бумаги.
Выдвиньте наружу лоток 2 и лоток 3 для поиска зоны застревания, и вытащите
застрявшую бумагу. Затем откройте и закройте переднюю крышку. Откройте
переднюю крышку, даже если под крышкой нет застрявшей бумаги. Ошибка на
дисплее не сбросится, пока вы не откроете и не закроете переднюю крышку.

См.
• «6.1 Устранение застревания бумаги» (стр. 113)

Откройте лоток 4,3
& 2. Устраните застр.

затем
Откройте-закр. A

В принтере возникло застревание бумаги.
Выдвиньте наружу лоток 2, лоток 3 и лоток 4 для поиска зоны застревания, и
вытащите застрявшую бумагу. Затем откройте и закройте переднюю крышку.
Откройте переднюю крышку, даже если под крышкой нет застрявшей бумаги.
Ошибка на дисплее не сбросится, пока вы не откроете и не закроете переднюю
крышку.

См.
• «6.1 Устранение застревания бумаги» (стр. 113)

Мало памяти

Нажмите SET
и отмените зад.

Задание нельзя распечатать, так как объем памяти недостаточный.
Отмените задание печати нажатием кнопки

<OK/Извлечение> на

панели управления.
Уменьшите число файлов для печати и попробуйте распечатать еще раз. Если
опять появится это сообщение, то мы советуем установить дополнительную
память.

Ошибка PDL

Нажмите SET
и отмените зад.

При обработке задания возникла ошибка.
Отмените задание печати нажатием кнопки

<OK/Извлечение> на

панели управления.
Проверьте, нет ли проблемы с данными для печати.

Задвиньте
все лотки

Задание запросило лоток бумаги, но открыт один из лотков выше его.
Закройте открытый лоток

Задвиньте лоток N
(N: лоток 2 — 5)

Открыт лоток N.
Задвиньте лоток в принтер до упора.

Задвиньте лотки

Один из лотков открыт в процессе печати.
Задвиньте лоток в принтер до упора.

Готов к печати
Набор обслуж.

Готов к печати
Скоро замена

Вскоре необходимо заменить ремонтный комплект (регулярно заменяемые
детали). У вас должен быть новый комплект обслуживания (ремонтный).

Готов к печати
Картридж с тон.

Готов к печати
Скоро замена

Вскоре необходимо заменить принт-картридж. У вас должен быть новый
картридж.

Перезагр.принтер
(***-***)

Это отказ принтера.
Выключите питание, подождите погасания дисплея, и затем снова включите
питание принтера. Если опять отображается этот код ошибки, запишите
его (***-***) и обращайтесь в ваш сервисный центр или к вашему дилеру.

См.
• «Коды ошибок» (стр. 133)

Сообщение

Признак/Причина/Устранение

Сообщения об ошибках и коды ошибок...

Устранение неисправностей ЗаменаКартридж с тон. В принт…

Страница 152

  • Изображение
  • Текст

132

6 Устранение неисправностей

Замена
Картридж с тон.

В принт-картридже закончился тонер.
Замените принт-картридж.

См.
• «Замена картриджа принтера» (стр. 141)
• «Тип расходного материала» (стр. 139)

Загр. лоток N
xx xx xxxx

(N: лоток 2 — 5)

Формат загруженной в лоток N бумаги не соответствует формату, указанному
для задания.
Загрузите указанную в сообщении бумагу (xx xx xxxx) в лоток N.

См.
• «Загрузка бумаги в лотки 2 — 5» (стр. 66)

Ошибка ***-***
Перезагр.принтер

Произошла системная ошибка.
Выключите питание, подождите погасания дисплея, и затем снова
включите питание принтера. Если опять отображается этот код ошибки,
запишите его (***-***) и обращайтесь в ваш сервисный центр или к вашему
дилеру.

См.
• «Коды ошибок» (стр. 133)

Неизвестный тип

Нажмите SET
и отмените зад.

Бал запрошен Автовыбор лотка при настройке [Приоритет бумаги] в [Выкл].
Отмените задание печати нажатием кнопки

<OK/Извлечение> на

панели управления.
Настройте порядок приоритета для лотков или вручную выберите лоток с
панели управления.

См.
• «[Настр-ка системы]» (стр. 95)

Неверный формат
Бумагу в обходн.

Формат загруженной в лоток 1 (обходной) бумаги не соответствует формату
бумаги, настроенному в драйвере принтера или с панели управления.
Загрузите бумагу с форматом, указанным в драйвере принетра или с панели
управления.

См.
• «Загрузка бумаги в лоток 1 (обходной)» (стр. 64)

Неверный формат
Бумагу в лоток N

Или провер.набор

(N: лоток 2 — 5)

Формат бумаги, загруженной в лоток N, не соответствует формату,
настроенному на шкале формата бумаги лотка.
Выдвиньте наружу лоток N, проверьте формат бумагу и настройку шкалы лотка
и вставьте лоток в принтер.

См.
• «Загрузка бумаги в лотки 2 — 5» (стр. 66)

Сообщение

Признак/Причина/Устранение

Устранение неисправностей ЗаменаКартридж с тон. В принт...

6.6 Сообщения об ошибках и коды ошибок

133

Коды ошибок

Коды ошибок — это шестизначные числа, выводимые на панель управления при
возникновении ошибки. Такие ошибки включают в себя неверные задания печати и
неисправности принтера.
Коды ошибок являются важной информацией, указывающей на причины ошибок. При
звонке в сервисный центр или к вашему дилеру у вас должны быть подготовлены
записи кодов ошибок.

В следующей таблице перечислены коды ошибок, которые могут быть устранены
пользователем. Если отображается код ошибки, то проверьте, нет ли его в
следующей таблице.
Следующие коды ошибок перечислены в возрастающем порядке.

Код ошибки

Причина/Устранение

010-397

Блок термического закрепления тонера (фьюзер) может быть установлен неправильно или
неисправен.
Выключите принтер и откройте переднюю крышку, потянув на себя рычаги освобождения
передней крышки («А»).. Проверьте, что рычаги с обеих сторон блока закрепление тонера
надежно зафиксированы, и затем включите питание принтера.

Если снова показан этот же код ошибки, то обращайтесь в ваш сервисный центр или к
вашему дилеру.

077-215

Податчик листов (опцонный) неправильно установлен в принтере. Выключите питание
принтера, проверьте, что податчик листов правильно установлен в принтере, и затем снова
включите питание.

См.

Руководство по установке податчика на 550 листов

Перезагр.принтер
(116-316)

код ошибки

Коды ошибок

134

6 Устранение неисправностей

077-216

Блок двусторонней печати (опцонный) неправильно вставлен в принтер. Выключите
питание принтера, проверьте, что соединитель кабеля блока двусторонней печати
правильно подключен к принтеру, и затем снова включите питание.

См.

Руководство по установке блока двусторонней печати’

Код ошибки

Причина/Устранение

Устранение неисправностей...

7 проблемы, относящиеся к сети, Проблемы служб centreware internet services

Страница 155

  • Изображение
  • Текст

6.7 Проблемы, относящиеся к сети

135

6.7

Проблемы, относящиеся к сети

Информация по устранению связанных с сетью проблем печати приведена на
компакт-диске с документацией.
Ниже перечислены проблемы, которые могут возникнуть при использовании
CentreWare Internet Services, печати по электронной почте и StatusMessenger. Если
показано сообщение об ошибке или код ошибки, для её устранения перейдите к
разделу «6.6 Сообщения об ошибках и коды ошибок» (стр. 129).

Проблемы служб CentreWare Internet Services

Признак

Причина/Устранение

Текст введен в поле ввода без
превышения отведенных для
ввода числа байтов (при этом
каждый специальный символ
считается за 2 байта), но весь
текст не сохранился.

Принтер использует код Unicode UTF-8 для сохранения символов, введенных в
CentreWare Internet Services. Обычно в UTF-8 требуется от 2 до 4 байтов для
сохранения одного специального символа (не буквенноцифрового).
Введенный вами текст мог превысить максимальное число байтов, отведенное
для поля ввода, и поэтому не был сохранен.

Нет доступа к CentreWare
Internet Services.

Нормально ли работает принтер?
Проверьте, включен ли принтер.

Запущена ли служба Internet Services?
Распечатайте список [Настр. принтера] чтобы проверить, включены ли службы
Internet Services.

Правильно ли введен адрес URL?
Проверьте URL. Если вы все равно не можете получить доступа к службе, то
введите IP-адрес принтера вместо URL.

Правильно ли настроен номер порта HTTP?
Еще раз проверьте номер порта HTTP. Если вы изменили номер порта, нужно
ввести «:» (двоеточие) и затем номер порта после адреса при доступе к
CentreWare Internet Services.
Пример) http://printer1.example.com:80/

Если включена связь с сервером по SSL/TLS, то правильно ли вы ввели адрес в
адресное поле?
Если разрешена связь с сервером по протоколу SSL/TLS, то введите «https»
перед адресом вместо «http». Кроме того, если вы изменили номер порта
SSL/TLS, то введите «:» (двоеточие) перед номером порта.

Использует ли ваш обозреватель Интернет прокси-сервер?
CentreWare Internet Services могут быть недоступны в зависимости от
используемого прокси-сервера.
Попытайтесь вызвать службы без прокси-сервера.

См.
• Оперативная справочная система вашего обозревателя Интернет

В обозреватели Интернет
выводится сообщение
«Подождите…» и оно не
исчезает.

Немного подождите, как указано.
Если ничего не меняется, то обновите экран обозревателя. Если это не
помогает, то проверьте, нормально ли работает принтер.

Не отображается самая
последняя информация.

Нажмите [Обновить].

7 проблемы, относящиеся к сети, Проблемы служб centreware internet services

136

6 Устранение неисправностей

Кнопка [Обновить] не работает.
Содержимое правой рамки не
меняется, даже если в левой
рамке выбрана другая тема.
Служба работает медленно.

Поддерживаются ли ваша операционная система и обозреватель Интернет
службой CentreWare Internet Services?
Список поддерживаемых службой операционных систем и веб-браузеров
приведен в разделе «1.5 Конфигурирование принтера с помощью служб
CentreWare Internet Services» (стр. 13).

Если ваш обозреватель использует прокси-сервер, то окно может обновляться
неправильно или замедлить работу.
Попытайтесь вызвать службы CentreWare Internet Services без прокси-сервера.

Старая информация может кэшироваться вашим обозревателем Интернет.
Сотрите всю информацию в кэше обозревателя.

Отображаемая на экране
информация искажена.

Измените размер окна или настройку размера шрифта в обозревателе
Интернет.

Нажатие [Применить] не
показывает новых настроек.

Правильно ли вы ввели значения?
Если величины недопустимы, то будет показано сообщение об ошибке.
Проверьте, что все значения введены правильно.

Забыт ИД или пароль
системного администратора и
нельзя изменить настройки.

ИД и пароль по умолчанию для системного администратора в CentreWare
Internet Services — это:
• ИД пользователя: 11111
• пароль: x-admin

Если вы не можете вспомнить ИД и пароль, Инициализируйте настройки в
пункте [Иниц/удал данные] > [Иниц/сетев.порт] на панели управления. Однако
эта операция сбросит в значения по умолчанию все относящиеся к сети
настройки. Перед инициализацией настроек рекомендуется записать текущие
настройки, распечатав для этого список [Настр. принтера].

Служба не принимает ИД или
пароля пользователя.

Если у вас возникнет ошибка входа четыре раза подряд после включения
питания или после последнего успешного входа, то ваш доступ к службе будет
заблокирован. В зависимости от используемого обозревателя Интернет окно
входа может не закрываться, пока вы не отмените попытку входа.
В таком случае перезагрузите принтер и попробуйте войти в него еще раз.

Язык дисплея отличается от
нужного вам.

Измените настройку языка дисплея в вашем обозревателе Интернет.

См.
• Оперативная справочная система вашего обозревателя Интернет

Если вы одновременно ведете доступ к принтеру из нескольких обозревателей
Интернет и StatusMessenger с разными языками, то полученная от принтера
строчка символов может отличаться от настройки языка в вашем обозревателе.
В этом случае обновите экран обозревателя Интернет.

Такая проблема может также возникнуть, если ваш обозреватель использует
прокси-сервер.
Попытайтесь вызвать службы без прокси-сервера.

См.
• Оперативная справочная система вашего обозревателя Интернет

Подключение к CentreWare
Internet Services было
отменено, или выведено
сообщение «Страница не
содержит данных».

Это может случиться, если вы слишком часто обновляете окно обозревателя
Интернет. Старайтесь не обновлять окно обозревателя слишком часто.
Также, не оставляйте вкладки [Состояние] или [Задания] открытыми в
нескольких обозревателях.

Кнопки отображаются как
ссылки URL.

Некоторые кнопки службы используют JavaScript. Такие кнопки не
отображаются, если JavaScript не работает или выключен. В таком случае
кнопки отображаются как ссылки URL.
Мы рекомендуем включить JavaScript в вашем обозревателе Интернет.

Признак

Причина/Устранение

Устранение неисправностей Кнопка...

6.7 Проблемы, относящиеся к сети

137

Проблемы печати электронной почты/StatusMessenger

Признак

Причина/Устранение

Не удается проверить
состояние принтера по
электронной почте.
(StatusMessenger)

Проверьте, что [Свойства] > [Состояние порта] > [StatusMessenger] в
CentreWare Internet Services установлено на [Включено].

Проверьте следующие настройки в полях [Свойства] > [Эл. почта] в CentreWare
Internet Services.
• Сконфигурирован ли адрес электронной почты принтера?
• Правильно ли заданы остальные настройки, например, сервер SMTP и

сервер POP3?

• Включена ли функция [Разрешенный адрес эл.почты] (адреса эл. почты, с

которых принтер может получать сообщения)? Включен ли ваш адрес в
[Разрешенный адрес эл.почты]?

Правильно ли введен [Пароль для данных, доступных только для чтения] или
[Пароль для задания печати] в электронной почте (если эти пароли
установлены)?
Убедитесь, что вы указали такой же пароль, какой настроен в [Свойства] >
[Эл. почта] в CentreWare Internet Services.

Правильно ли записаны команды в сообщении электронной почты?
Обязательно записывайте команды правильно.

См.
• «7.5 Проверка состояния принтера по электронной почте» (стр. 150)

Нормально ли работает сервер SMTP и сервер POP3?
Попросите администратора сети проверить работу этих серверов.

Принтер не присылает
оповещения об ошибках по
электронной почте
(StatusMessenger)

Проверьте, что [Свойства] > [Состояние порта] > [StatusMessenger] в
CentreWare Internet Services настроен в [Включено].

Проверьте следующие настройки в полях [Свойства] > [Эл. почта] и
[StatusMessenger] в CentreWare Internet Services.
• Сконфигурирован ли адрес электронной почты принтера?
• Правильно ли заданы остальные настройки, например, сервер SMTP и

сервер POP3?

• Правильно ли настроены пункты или события, подлежащие оповещению?
• Правильно ли заданы адреса электронной почты получателей?

Нормально ли работает сервер SMTP и сервер POP3?
Попросите администратора сети проверить работу этих серверов.

Некоторые пункты не
отображаются в журнале
заданий

Если вы просматриваете журнал заданий печати по эл. почте в CentreWare
Internet Services, то поля [Имя задания], [Владелец], [Имя хоста], [I/F хоста] и
[Время отправки задания] будут пустыми. Эти пункты также будут пустыми в
[Отчет журнала заданий]. [Порт] в [Отчет журнала заданий] будет указан
как [POP3].

Проблемы печати электронной почты/statusmessenger

138

6 Устранение неисправностей

Устранение неисправностей...

7 обслуживание, Обслуживание, 7обслуживание

1 замена расходных материалов, Тип расходного материала

  • Изображение
  • Текст

7.1 Замена расходных материалов

139

7

Обслуживание

7.1

Замена расходных материалов

Тип расходного материала

Для принтера доступны следующие расходные материалы. Для заказа их
обращайтесь к дилеру, у которого вы приобрели принтер.

Важная информация
• Если вы не будете использовать рекомендованные Xerox расходные материалы, то

эксплуатационные характеристики принтера могут быть не на оптимальном уровне. Используйте
только расходные материалы, рекомендованные для этого изделия

• Ресурс расходных материалов в печатных страницах зависит от заданий печати, печатаемых

документов и частоты включения/выключения питания. Более подробная информация приведена
в разделе «Ресурс расходных материалов и периодически заменяемые узлы» (стр. 187).

„

Картридж принтера

Картридж, внутри которого находятся тонер, фотопроводящий барабан и блок
проявления. Картридж принтера необходимо заменять, когда отпечатки становятся
светлыми или снижается их качество. Сведения о периодичности и порядке замены
картриджа принтера приведены в разделах «Ресурс расходных материалов и
периодически заменяемые узлы» (стр. 187) и «Замена картриджа принтера»
(стр. 141).

Название продукта

Код продукта

Ресурс в страницах

(справочное значение)

Картридж принтера 10К

113R00737

Примерно 10000 страниц

7 обслуживание, Обслуживание, 7обслуживание

140

7 Обслуживание

Правила обращения с расходными материалами

• Не храните расходные материалы в вертикальном положении.

• Не распаковывайте расходные материалы и запчасти вплоть до момента

использования.

• Не храните расходные материалы и запчасти в следующих условиях:

• при высокой температуре и влажности
• вблизи источников тепла
• при воздействии прямого солнечного света
• в запыленных местах

• При использовании расходных материалов выполняйте все меры

предосторожности, указанные на упаковке.

• Мы рекомендуем иметь резервный запас расходных материалов.

Правила обращения с расходными материалами

Комментарии

005-123 DADF Simplex/Side 1 Registration Sensor On Jam RAP

BSD-ON: BSD 5.6 Document Scan, Invert and Exit Transportation

005-123 The DADF registration sensor does not turn on within the specified time after the DADF pre registration sensor on.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.
• GP 8 How to Check a Solenoid or Clutch.

Perform the steps that follow:

1. Check for a foreign substance in the document path.
2. Check the surface of the takeaway roll and registration roll for foreign substances or wear. Clean or install new components as necessary, PL 5.50.
3. Enter dC330, code 005-110. Check the DADF registration sensor, PL 5.70 Item 3.
4. Enter dC330, code 005-206. Check the DADF pre registration sensor, PL 5.70 Item 3.
5. Enter dC330, code 005-098. Check the DADF takeaway clutch, (W/O TAG 002, PL 5.35 Item 2), (W/TAG 002, PL 5.36 Item 2).
6. Enter dC330, code 005-008. Check the DADF feed motor, PL 5.30 Item 3.
7. Check the drive gears, (W/OTAG 002, PL 5.35), (W/TAG 002, PL 5.36) for wear or damage. Install new components as necessary.
8. If the fault persists, install a new DADF PWB, PL 5.10 Item 11.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

BSD-ON:

BSD 10.1 — Fusing Heat Control

After the Main Lamp turned On during warm up, the Control Thermistor did not detect

READY temperature within the specified time.

After the Main Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during standby, the Control Thermistor did not detect a

specific temperature within the specified time.

After the empty rotation started, the Control Thermistor did not detect the empty rotation

finishing temperature within the specified time.

After the Main Lamp turned On during printing, the Control Thermistor did not detect a

specific temperature within the specified time.

After the Sub Lamp turned On during printing, the Control Thermistor did not detect a spe-

cific temperature within the specified time.

Initial Actions

Voltage Supply

Indoor Temperature

Procedure

NOTE: When this fault occurs, NVM location 744-005 is set to 1, 2, or 3, depending on the

fault. You must reset this location to 0 in order to clear the fault.

Check for paper on the Fuser. The Fuser has no paper wrapped round it.

Y

N

Remove the paper.

Check the installation of the Fuser Unit. The Fuser Unit is securely installed.

Y

N

Install the Fuser Unit securely.

Remove the Fuser Unit. Check the conductivity of the contact points of the Thermostat. The

contact points are connected.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Main Lamp between J621-6 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Main Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Sub Lamp between J621-2 and J621-7 for an open circuit or a

short circuit

(BSD

10.1). The resistance of the Sub Lamp is 100 ohms or lower.

Y

N

Replace the Fuser Unit

(PL

7.1).

Check the resistance of the Control (Center) Thermistor between J621-5 and J621-1

10.1). There is no open circuit in the Center STS and the resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

(PL

7.1).

A

Initial Issue

WorkCentre 5335 Family Service Documentation

A

Check the resistance of the Rear Thermistor between J621-7 and J621-3

resistance is 3k ohms or higher.

Y

N

Replace the Fuser Unit

Check the wire between P/J411-B7 and J621-7 for an open circuit or a short circuit (

10.1). The wire between

short circuit.

Y

N

Repair the open circuit or short circuit.

Check the wire between

The wire between

Y

N

Repair the open circuit or short circuit.

Replace the Fuser Unit

If the problem persists, replace the MCU PWB

(BSD

07/2011

2-83

BUS Updated 12/2011

(PL

7.1).

P/J411

and

J621

is conducting without an open circuit or a

P/J414

and

P530

for an open circuit or a short circuit

P/J414

and

P530

conducts and if free of a short circuit.

(PL

7.1). If the problem persists, replace the AC Drive PWB

(PL

18.2).

(BSD

10.1). The

BSD

(BSD

10.1).

(PL

18.2)

Status Indicator RAPs

010-338

Thanks Thanks:  0

Likes Likes:  0

Dislikes Dislikes:  0

  1. 09-18-2017

    #1

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  &quot;fuser unit fail&quot;


    Rep Power
    45

    Thumbs up Phaser 7100N with error 010-338 «fuser unit fail»

    Customer called with error 010-338 on Phaser 7100n. Customer said he just changed fuser unit to get rid of error but still has 010-338.Any help is appreciated. Is there a reset procedure on this machine that is necessary
    after fuser unit is changed. I asked cust. if sure it was a new unit and he said yes. Any advice is appreciated. I will check SM in meantime to see if I see anything though I thought I saw this was a fuser unit fail error but
    did not see a service mode reset procedure for this. Frank/ActionPhotocopy


  2. 09-18-2017

    #2

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Nothing to do with the fuser.
    Check for toner low or empty


  3. 09-18-2017

    #3

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  &quot;fuser unit fail&quot;


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Hi Adi . Thank you for your info. It is a little confusing because the Phaser 7100 service manual on page 2-83 states that error 010-338 is a Fuser Unit On Time Fail Error.

    Originally the customer called and said he had been using the machine although there was a lot of toner spillage but machine was working. Then change toner cartridge(BLack) message.
    After customer changed cartridge he got the 010-338 error. I told him to make sure it was OEM before calling for service. he bought OEM and still had error. I saw info in service manual and told customer
    he would probably need fuser unit. He ordered it himself from amazon.com and called this morning to say he still had error. As I am writing this customer just called to say he is out of office but thinks error
    has disappeared as machine is asking for loading of paper. He will call tomorrow. Frank


  4. 09-18-2017

    #4

    Re: Phaser 7100N with error 010-338 «fuser unit fail»

    It is machine software glitch.
    Was ( or is ) technical bulletin about this on Eureka.


  5. 09-18-2017

    #5

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  &quot;fuser unit fail&quot;


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    Customer supposedly changed black toner for oem. Anyway he will call me tomorrow to let me know if working now


  6. 09-21-2017

    #6

    axyun is offline


    Service Manager

    1,000+ Posts

    Phaser 7100N with error 010-338  &quot;fuser unit fail&quot;


    Rep Power
    45

    Thumbs up Re: Phaser 7100N with error 010-338 «fuser unit fail»

    customer says machine is now working


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

background image

Коды неисправностей

При сбое во время печати или неисправности аппарата на экран выводится код
неисправности. Если на экране отображается код неисправности, которого нет в
таблице ниже, или неисправность не удается устранить, выполнив указанные далее
действия, обратитесь в сервисный центр Xerox. При отображении кода
неисправности сбрасываются все данные печати на аппарате, а также данные в
его встроенной памяти.

Рекомендуемое решение

Вероятная причина

Код неисправности

Откройте передние дверцы и
убедитесь, что дверца
фьюзера закрыта.
Выключите и снова включите
аппарат.

Выдвижная секция фьюзера
открыта

010 300

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибки скорости ремня
фьюзера

010 310, 010 311, 010 312,

010 313, 010 314, 010 315,
010 316, 010 317, 010 318,

010 319, 010 321, 010 323,

010 324, 010 325, 010 326,

010 327, 010 328, 010 333,

010 334, 010 335, 010 336,

010 337, 010 338, 010 341,

010 342, 010 343, 010 344,

010 347, 010 348, 010 349,

010 350, 010 351, 010 352,

010 353, 010 354, 010 355,

010 356, 010 357, 010 369,

010 370, 010 371, 010 374,

010 379, 010 380, 010 386,

010 387, 010 389

Выключите и снова включите
аппарат.

Если неисправность
устранить не удается,
обратитесь в сервисный
центр.

Ошибка температуры
фьюзера или фьюзер
отключен

010 360, 010 401

10-25

Печатная машина Xerox

®

Color 800/1000

Руководство пользователя

Устранение неисправностей

The most common error codes.

Error
077-214 Description: Tray Module Logic Fail RAP I/F mismatch between the IOT and the Tray Module was detected.
062-396 Description: CCD Cable Connection Fail RAP A CCD Flat Cable connection error was detected.
092-315 Description: ATC Fail RAP The frequency at which the ATC Average Fail or the ATC Amplitude Fail has been occurring has exceeded the threshold value. NOTE: • Although this Fault can be cleared by turning the power OFF and ON and it will be possible to out
041-310 Description: IM Logic Fail RAP The IM (Image Management) software control error was detected.
005-940 Description: DADF No Original RAP Operation Fail. Final document correction notification due to DADF document being pulled out.
092-315 Description: ATC Fail RAP The frequency at which the ATC Average Fail or the ATC Amplitude Fail has been occurring has exceeded the threshold value. NOTE: • Although this Fault can be cleared by turning the power OFF and ON and it will be possible to out
005-940 Description: DADF No Original RAP Operation Fail. Final document correction notification due to DADF document being pulled out.
062-396 Description: CCD Cable Connection Fail RAP A CCD Flat Cable connection error was detected.
012-212 Description: Stacker Tray Upper Limit Failure RAP (LX) The stacker has continued to elevate after the defined period of time has passed since Stacker No Paper Sensor is ON during stacker elevation.
012-291 Description: (Integrated Finisher) Stapler Fail RAP Within a specified time after the Staple Motor started rotating in reverse direction, the Staple Head Home Sensor was never detected turning On.

005-123 DADF Simplex/Side 1 Registration Sensor On Jam RAP

BSD-ON: BSD 5.6 Document Scan, Invert and Exit Transportation

005-123 The DADF registration sensor does not turn on within the specified time after the DADF pre registration sensor on.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.
• GP 8 How to Check a Solenoid or Clutch.

Perform the steps that follow:

1. Check for a foreign substance in the document path.
2. Check the surface of the takeaway roll and registration roll for foreign substances or wear. Clean or install new components as necessary, PL 5.50.
3. Enter dC330, code 005-110. Check the DADF registration sensor, PL 5.70 Item 3.
4. Enter dC330, code 005-206. Check the DADF pre registration sensor, PL 5.70 Item 3.
5. Enter dC330, code 005-098. Check the DADF takeaway clutch, (W/O TAG 002, PL 5.35 Item 2), (W/TAG 002, PL 5.36 Item 2).
6. Enter dC330, code 005-008. Check the DADF feed motor, PL 5.30 Item 3.
7. Check the drive gears, (W/OTAG 002, PL 5.35), (W/TAG 002, PL 5.36) for wear or damage. Install new components as necessary.
8. If the fault persists, install a new DADF PWB, PL 5.10 Item 11.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Видео #92 Замена девелопера Xerox WC 5325  5330  5335  5222  5225  5230  C118  123 | Phaser 5500 (автор: ЗаправкинЪ)25:14

#92 Замена девелопера Xerox WC 5325 5330 5335 5222 5225 5230 C118 123 | Phaser 5500

Видео Xerox WorkCentre 5335 Informational Video (автор: GWCopierSupplies)03:57

Xerox WorkCentre 5335 Informational Video

Видео Инструкция как разобрать Xerox Phaser 3250 (Чистка печки) (автор: Somas Service)22:46

Инструкция как разобрать Xerox Phaser 3250 (Чистка печки)

Видео dscf0376 - - xerox phaser 5335 xerox (автор: techlabsby)02:36

dscf0376 — — xerox phaser 5335 xerox

Видео Xerox Phaser 5335 Драйвер Windows 7 (автор: Pavel Vorobyov)03:17

Xerox Phaser 5335 Драйвер Windows 7

Видео Обзор принтера XEROX Phaser 3052NI (автор: APEKS)08:13

Обзор принтера XEROX Phaser 3052NI

Видео Ремонт поддона Xerox Phaser 5335 (автор: Николай Хазов)47:25

Ремонт поддона Xerox Phaser 5335

Видео dscf0376 xerox phaser 5335 xerox Low) (автор: Денис Шпаков)02:36

dscf0376 xerox phaser 5335 xerox Low)

6.6 Сообщения об ошибках и коды ошибок

131

Откройте лоток 2
Устраните застр.

затем
Откройте-закр. A

В принтере возникло застревание бумаги.
Выдвиньте наружу лоток 2 для поиска зоны застревания, и вытащите
застрявшую бумагу. Затем откройте и закройте переднюю крышку. Откройте
переднюю крышку, даже если под крышкой нет застрявшей бумаги. Ошибка на
дисплее не сбросится, пока вы не откроете и не закроете переднюю крышку.

См.
• «6.1 Устранение застревания бумаги» (стр. 113)

Откройте л.2 и 3
Устраните застр.

затем
Откройте-закр. A

В принтере возникло застревание бумаги.
Выдвиньте наружу лоток 2 и лоток 3 для поиска зоны застревания, и вытащите
застрявшую бумагу. Затем откройте и закройте переднюю крышку. Откройте
переднюю крышку, даже если под крышкой нет застрявшей бумаги. Ошибка на
дисплее не сбросится, пока вы не откроете и не закроете переднюю крышку.

См.
• «6.1 Устранение застревания бумаги» (стр. 113)

Откройте лоток 4,3
& 2. Устраните застр.

затем
Откройте-закр. A

В принтере возникло застревание бумаги.
Выдвиньте наружу лоток 2, лоток 3 и лоток 4 для поиска зоны застревания, и
вытащите застрявшую бумагу. Затем откройте и закройте переднюю крышку.
Откройте переднюю крышку, даже если под крышкой нет застрявшей бумаги.
Ошибка на дисплее не сбросится, пока вы не откроете и не закроете переднюю
крышку.

См.
• «6.1 Устранение застревания бумаги» (стр. 113)

Мало памяти

Нажмите SET
и отмените зад.

Задание нельзя распечатать, так как объем памяти недостаточный.
Отмените задание печати нажатием кнопки

<OK/Извлечение> на

панели управления.
Уменьшите число файлов для печати и попробуйте распечатать еще раз. Если
опять появится это сообщение, то мы советуем установить дополнительную
память.

Ошибка PDL

Нажмите SET
и отмените зад.

При обработке задания возникла ошибка.
Отмените задание печати нажатием кнопки

<OK/Извлечение> на

панели управления.
Проверьте, нет ли проблемы с данными для печати.

Задвиньте
все лотки

Задание запросило лоток бумаги, но открыт один из лотков выше его.
Закройте открытый лоток

Задвиньте лоток N
(N: лоток 2 — 5)

Открыт лоток N.
Задвиньте лоток в принтер до упора.

Задвиньте лотки

Один из лотков открыт в процессе печати.
Задвиньте лоток в принтер до упора.

Готов к печати
Набор обслуж.

Готов к печати
Скоро замена

Вскоре необходимо заменить ремонтный комплект (регулярно заменяемые
детали). У вас должен быть новый комплект обслуживания (ремонтный).

Готов к печати
Картридж с тон.

Готов к печати
Скоро замена

Вскоре необходимо заменить принт-картридж. У вас должен быть новый
картридж.

Перезагр.принтер
(***-***)

Это отказ принтера.
Выключите питание, подождите погасания дисплея, и затем снова включите
питание принтера. Если опять отображается этот код ошибки, запишите
его (***-***) и обращайтесь в ваш сервисный центр или к вашему дилеру.

См.
• «Коды ошибок» (стр. 133)

Сообщение

Признак/Причина/Устранение

Сообщения об ошибках и коды ошибок...

Устранение неисправностей ЗаменаКартридж с тон. В принт…

Страница 152

  • Изображение
  • Текст

132

6 Устранение неисправностей

Замена
Картридж с тон.

В принт-картридже закончился тонер.
Замените принт-картридж.

См.
• «Замена картриджа принтера» (стр. 141)
• «Тип расходного материала» (стр. 139)

Загр. лоток N
xx xx xxxx

(N: лоток 2 — 5)

Формат загруженной в лоток N бумаги не соответствует формату, указанному
для задания.
Загрузите указанную в сообщении бумагу (xx xx xxxx) в лоток N.

См.
• «Загрузка бумаги в лотки 2 — 5» (стр. 66)

Ошибка ***-***
Перезагр.принтер

Произошла системная ошибка.
Выключите питание, подождите погасания дисплея, и затем снова
включите питание принтера. Если опять отображается этот код ошибки,
запишите его (***-***) и обращайтесь в ваш сервисный центр или к вашему
дилеру.

См.
• «Коды ошибок» (стр. 133)

Неизвестный тип

Нажмите SET
и отмените зад.

Бал запрошен Автовыбор лотка при настройке [Приоритет бумаги] в [Выкл].
Отмените задание печати нажатием кнопки

<OK/Извлечение> на

панели управления.
Настройте порядок приоритета для лотков или вручную выберите лоток с
панели управления.

См.
• «[Настр-ка системы]» (стр. 95)

Неверный формат
Бумагу в обходн.

Формат загруженной в лоток 1 (обходной) бумаги не соответствует формату
бумаги, настроенному в драйвере принтера или с панели управления.
Загрузите бумагу с форматом, указанным в драйвере принетра или с панели
управления.

См.
• «Загрузка бумаги в лоток 1 (обходной)» (стр. 64)

Неверный формат
Бумагу в лоток N

Или провер.набор

(N: лоток 2 — 5)

Формат бумаги, загруженной в лоток N, не соответствует формату,
настроенному на шкале формата бумаги лотка.
Выдвиньте наружу лоток N, проверьте формат бумагу и настройку шкалы лотка
и вставьте лоток в принтер.

См.
• «Загрузка бумаги в лотки 2 — 5» (стр. 66)

Сообщение

Признак/Причина/Устранение

Устранение неисправностей ЗаменаКартридж с тон. В принт...

6.6 Сообщения об ошибках и коды ошибок

133

Коды ошибок

Коды ошибок — это шестизначные числа, выводимые на панель управления при
возникновении ошибки. Такие ошибки включают в себя неверные задания печати и
неисправности принтера.
Коды ошибок являются важной информацией, указывающей на причины ошибок. При
звонке в сервисный центр или к вашему дилеру у вас должны быть подготовлены
записи кодов ошибок.

В следующей таблице перечислены коды ошибок, которые могут быть устранены
пользователем. Если отображается код ошибки, то проверьте, нет ли его в
следующей таблице.
Следующие коды ошибок перечислены в возрастающем порядке.

Код ошибки

Причина/Устранение

010-397

Блок термического закрепления тонера (фьюзер) может быть установлен неправильно или
неисправен.
Выключите принтер и откройте переднюю крышку, потянув на себя рычаги освобождения
передней крышки («А»).. Проверьте, что рычаги с обеих сторон блока закрепление тонера
надежно зафиксированы, и затем включите питание принтера.

Если снова показан этот же код ошибки, то обращайтесь в ваш сервисный центр или к
вашему дилеру.

077-215

Податчик листов (опцонный) неправильно установлен в принтере. Выключите питание
принтера, проверьте, что податчик листов правильно установлен в принтере, и затем снова
включите питание.

См.

Руководство по установке податчика на 550 листов

Перезагр.принтер
(116-316)

код ошибки

Коды ошибок

134

6 Устранение неисправностей

077-216

Блок двусторонней печати (опцонный) неправильно вставлен в принтер. Выключите
питание принтера, проверьте, что соединитель кабеля блока двусторонней печати
правильно подключен к принтеру, и затем снова включите питание.

См.

Руководство по установке блока двусторонней печати’

Код ошибки

Причина/Устранение

Устранение неисправностей...

7 проблемы, относящиеся к сети, Проблемы служб centreware internet services

Страница 155

  • Изображение
  • Текст

6.7 Проблемы, относящиеся к сети

135

6.7

Проблемы, относящиеся к сети

Информация по устранению связанных с сетью проблем печати приведена на
компакт-диске с документацией.
Ниже перечислены проблемы, которые могут возникнуть при использовании
CentreWare Internet Services, печати по электронной почте и StatusMessenger. Если
показано сообщение об ошибке или код ошибки, для её устранения перейдите к
разделу «6.6 Сообщения об ошибках и коды ошибок» (стр. 129).

Проблемы служб CentreWare Internet Services

Признак

Причина/Устранение

Текст введен в поле ввода без
превышения отведенных для
ввода числа байтов (при этом
каждый специальный символ
считается за 2 байта), но весь
текст не сохранился.

Принтер использует код Unicode UTF-8 для сохранения символов, введенных в
CentreWare Internet Services. Обычно в UTF-8 требуется от 2 до 4 байтов для
сохранения одного специального символа (не буквенноцифрового).
Введенный вами текст мог превысить максимальное число байтов, отведенное
для поля ввода, и поэтому не был сохранен.

Нет доступа к CentreWare
Internet Services.

Нормально ли работает принтер?
Проверьте, включен ли принтер.

Запущена ли служба Internet Services?
Распечатайте список [Настр. принтера] чтобы проверить, включены ли службы
Internet Services.

Правильно ли введен адрес URL?
Проверьте URL. Если вы все равно не можете получить доступа к службе, то
введите IP-адрес принтера вместо URL.

Правильно ли настроен номер порта HTTP?
Еще раз проверьте номер порта HTTP. Если вы изменили номер порта, нужно
ввести «:» (двоеточие) и затем номер порта после адреса при доступе к
CentreWare Internet Services.
Пример) http://printer1.example.com:80/

Если включена связь с сервером по SSL/TLS, то правильно ли вы ввели адрес в
адресное поле?
Если разрешена связь с сервером по протоколу SSL/TLS, то введите «https»
перед адресом вместо «http». Кроме того, если вы изменили номер порта
SSL/TLS, то введите «:» (двоеточие) перед номером порта.

Использует ли ваш обозреватель Интернет прокси-сервер?
CentreWare Internet Services могут быть недоступны в зависимости от
используемого прокси-сервера.
Попытайтесь вызвать службы без прокси-сервера.

См.
• Оперативная справочная система вашего обозревателя Интернет

В обозреватели Интернет
выводится сообщение
«Подождите…» и оно не
исчезает.

Немного подождите, как указано.
Если ничего не меняется, то обновите экран обозревателя. Если это не
помогает, то проверьте, нормально ли работает принтер.

Не отображается самая
последняя информация.

Нажмите [Обновить].

7 проблемы, относящиеся к сети, Проблемы служб centreware internet services

136

6 Устранение неисправностей

Кнопка [Обновить] не работает.
Содержимое правой рамки не
меняется, даже если в левой
рамке выбрана другая тема.
Служба работает медленно.

Поддерживаются ли ваша операционная система и обозреватель Интернет
службой CentreWare Internet Services?
Список поддерживаемых службой операционных систем и веб-браузеров
приведен в разделе «1.5 Конфигурирование принтера с помощью служб
CentreWare Internet Services» (стр. 13).

Если ваш обозреватель использует прокси-сервер, то окно может обновляться
неправильно или замедлить работу.
Попытайтесь вызвать службы CentreWare Internet Services без прокси-сервера.

Старая информация может кэшироваться вашим обозревателем Интернет.
Сотрите всю информацию в кэше обозревателя.

Отображаемая на экране
информация искажена.

Измените размер окна или настройку размера шрифта в обозревателе
Интернет.

Нажатие [Применить] не
показывает новых настроек.

Правильно ли вы ввели значения?
Если величины недопустимы, то будет показано сообщение об ошибке.
Проверьте, что все значения введены правильно.

Забыт ИД или пароль
системного администратора и
нельзя изменить настройки.

ИД и пароль по умолчанию для системного администратора в CentreWare
Internet Services — это:
• ИД пользователя: 11111
• пароль: x-admin

Если вы не можете вспомнить ИД и пароль, Инициализируйте настройки в
пункте [Иниц/удал данные] > [Иниц/сетев.порт] на панели управления. Однако
эта операция сбросит в значения по умолчанию все относящиеся к сети
настройки. Перед инициализацией настроек рекомендуется записать текущие
настройки, распечатав для этого список [Настр. принтера].

Служба не принимает ИД или
пароля пользователя.

Если у вас возникнет ошибка входа четыре раза подряд после включения
питания или после последнего успешного входа, то ваш доступ к службе будет
заблокирован. В зависимости от используемого обозревателя Интернет окно
входа может не закрываться, пока вы не отмените попытку входа.
В таком случае перезагрузите принтер и попробуйте войти в него еще раз.

Язык дисплея отличается от
нужного вам.

Измените настройку языка дисплея в вашем обозревателе Интернет.

См.
• Оперативная справочная система вашего обозревателя Интернет

Если вы одновременно ведете доступ к принтеру из нескольких обозревателей
Интернет и StatusMessenger с разными языками, то полученная от принтера
строчка символов может отличаться от настройки языка в вашем обозревателе.
В этом случае обновите экран обозревателя Интернет.

Такая проблема может также возникнуть, если ваш обозреватель использует
прокси-сервер.
Попытайтесь вызвать службы без прокси-сервера.

См.
• Оперативная справочная система вашего обозревателя Интернет

Подключение к CentreWare
Internet Services было
отменено, или выведено
сообщение «Страница не
содержит данных».

Это может случиться, если вы слишком часто обновляете окно обозревателя
Интернет. Старайтесь не обновлять окно обозревателя слишком часто.
Также, не оставляйте вкладки [Состояние] или [Задания] открытыми в
нескольких обозревателях.

Кнопки отображаются как
ссылки URL.

Некоторые кнопки службы используют JavaScript. Такие кнопки не
отображаются, если JavaScript не работает или выключен. В таком случае
кнопки отображаются как ссылки URL.
Мы рекомендуем включить JavaScript в вашем обозревателе Интернет.

Признак

Причина/Устранение

Устранение неисправностей Кнопка...

6.7 Проблемы, относящиеся к сети

137

Проблемы печати электронной почты/StatusMessenger

Признак

Причина/Устранение

Не удается проверить
состояние принтера по
электронной почте.
(StatusMessenger)

Проверьте, что [Свойства] > [Состояние порта] > [StatusMessenger] в
CentreWare Internet Services установлено на [Включено].

Проверьте следующие настройки в полях [Свойства] > [Эл. почта] в CentreWare
Internet Services.
• Сконфигурирован ли адрес электронной почты принтера?
• Правильно ли заданы остальные настройки, например, сервер SMTP и

сервер POP3?

• Включена ли функция [Разрешенный адрес эл.почты] (адреса эл. почты, с

которых принтер может получать сообщения)? Включен ли ваш адрес в
[Разрешенный адрес эл.почты]?

Правильно ли введен [Пароль для данных, доступных только для чтения] или
[Пароль для задания печати] в электронной почте (если эти пароли
установлены)?
Убедитесь, что вы указали такой же пароль, какой настроен в [Свойства] >
[Эл. почта] в CentreWare Internet Services.

Правильно ли записаны команды в сообщении электронной почты?
Обязательно записывайте команды правильно.

См.
• «7.5 Проверка состояния принтера по электронной почте» (стр. 150)

Нормально ли работает сервер SMTP и сервер POP3?
Попросите администратора сети проверить работу этих серверов.

Принтер не присылает
оповещения об ошибках по
электронной почте
(StatusMessenger)

Проверьте, что [Свойства] > [Состояние порта] > [StatusMessenger] в
CentreWare Internet Services настроен в [Включено].

Проверьте следующие настройки в полях [Свойства] > [Эл. почта] и
[StatusMessenger] в CentreWare Internet Services.
• Сконфигурирован ли адрес электронной почты принтера?
• Правильно ли заданы остальные настройки, например, сервер SMTP и

сервер POP3?

• Правильно ли настроены пункты или события, подлежащие оповещению?
• Правильно ли заданы адреса электронной почты получателей?

Нормально ли работает сервер SMTP и сервер POP3?
Попросите администратора сети проверить работу этих серверов.

Некоторые пункты не
отображаются в журнале
заданий

Если вы просматриваете журнал заданий печати по эл. почте в CentreWare
Internet Services, то поля [Имя задания], [Владелец], [Имя хоста], [I/F хоста] и
[Время отправки задания] будут пустыми. Эти пункты также будут пустыми в
[Отчет журнала заданий]. [Порт] в [Отчет журнала заданий] будет указан
как [POP3].

Проблемы печати электронной почты/statusmessenger

138

6 Устранение неисправностей

Устранение неисправностей...

7 обслуживание, Обслуживание, 7обслуживание

1 замена расходных материалов, Тип расходного материала

  • Изображение
  • Текст

7.1 Замена расходных материалов

139

7

Обслуживание

7.1

Замена расходных материалов

Тип расходного материала

Для принтера доступны следующие расходные материалы. Для заказа их
обращайтесь к дилеру, у которого вы приобрели принтер.

Важная информация
• Если вы не будете использовать рекомендованные Xerox расходные материалы, то

эксплуатационные характеристики принтера могут быть не на оптимальном уровне. Используйте
только расходные материалы, рекомендованные для этого изделия

• Ресурс расходных материалов в печатных страницах зависит от заданий печати, печатаемых

документов и частоты включения/выключения питания. Более подробная информация приведена
в разделе «Ресурс расходных материалов и периодически заменяемые узлы» (стр. 187).

„

Картридж принтера

Картридж, внутри которого находятся тонер, фотопроводящий барабан и блок
проявления. Картридж принтера необходимо заменять, когда отпечатки становятся
светлыми или снижается их качество. Сведения о периодичности и порядке замены
картриджа принтера приведены в разделах «Ресурс расходных материалов и
периодически заменяемые узлы» (стр. 187) и «Замена картриджа принтера»
(стр. 141).

Название продукта

Код продукта

Ресурс в страницах

(справочное значение)

Картридж принтера 10К

113R00737

Примерно 10000 страниц

7 обслуживание, Обслуживание, 7обслуживание

140

7 Обслуживание

Правила обращения с расходными материалами

• Не храните расходные материалы в вертикальном положении.

• Не распаковывайте расходные материалы и запчасти вплоть до момента

использования.

• Не храните расходные материалы и запчасти в следующих условиях:

• при высокой температуре и влажности
• вблизи источников тепла
• при воздействии прямого солнечного света
• в запыленных местах

• При использовании расходных материалов выполняйте все меры

предосторожности, указанные на упаковке.

• Мы рекомендуем иметь резервный запас расходных материалов.

Правила обращения с расходными материалами

Комментарии

Понравилась статья? Поделить с друзьями:
  • Xerox 5325 ошибка 116 330
  • Xerox 5325 ошибка 072 101
  • Xerox 5325 ошибка 017 714
  • Xerox 5325 ошибка 024 747
  • Xerox 5325 ошибка 016 749