After the Registration Clutch turned On, the Registration Sensor did not turn Off within the

specified time.

Initial Actions

Power OFF/ON

Procedure

Check the Transport Roll for wear and paper powder. The Transport Roll is ok.

Y

N

Replace the Transport Roll.

Check for foreign substances, distortion and paper powder in the paper transport path. No

distortion, foreign substances, or paper powder are found in the paper transport path.

Y

N

Clear away the foreign substances and paper powder. Correct the distortion.

Execute

Component Control

[089-100 Registration Sensor]. Manually activate the actuator of

the Registration Sensor

(PL

2.4). The display changes.

Y

N

Check the connection of

P/J104

and P/J403.

rectly.

Y

N

Connect

P/J104

and P/J403.

Check the wire between J104 and J403 for an open circuit or a short circuit (BSD 8.7

1/Flag

2). The wire between J104 and J403 is conducting without an open circuit or

a short circuit.

Y

N

Repair the open circuit or short circuit.

Measure the voltage between the MCU PWB P403B-13 (+) and GND (-) (BSD 8.7

2). The voltage is approx. +5VDC.

Y

N

Replace the MCU PWB

(PL

9.1).

Measure the voltage between the MCU PWB P403B-8 (+) and GND (-) (BSD 8.7

Actuate the Registration Sensor with paper. The voltage changes.

Y

N

Replace the Registration Sensor

Replace the MCU PWB

(PL

9.1).

Execute

Component Control

[089-002 Registration Clutch ON]. The Registration Clutch

2.4) can be heard.

Y

N

Check the connection of

P/J215

and P/J403.

rectly.

A

Launch Version

WorkCentre 5225, 5230

P/J104

and

P/J403

are connected cor-

(PL

2.4).

P/J215

and

P/J403

are connected cor-

A

Y

N

Connect

P/J215

and P/J403.

Measure the resistance of the Registration Clutch

(BSD 8.7

Flag

3). The resistance is approx. 240Ohm.

Y

N

Replace the Registration Clutch

Check the wire between J215 and J403 for an open circuit or a short circuit (BSD 8.7

3). The wire between J215 and J403 is conducting without an open circuit or a short

circuit.

Y

N

Repair the open circuit or short circuit.

Replace the MCU PWB

Replace the MCU PWB

(PL

9.1).

Flag

Flag

Flag

1).

(PL

February, 2008

2-543

(PL

2.4) between P215-1 and P215-2

(PL

2.4).

(PL

9.1).

Flag

Status Indicator Raps

077-101

Thanks Thanks:  0

Likes Likes:  0

Dislikes Dislikes:  0

  1. 05-26-2015


    #1

    savi0r is offline


    Senior Tech

    250+ Posts


    Rep Power
    0

    xerox 5222 — 077-101

    Hi guys. So i have this machine, about 150k copies. It jams paper very often. Error code is 077-101. Put in a new registration assembly and still does the same thing. Could it pe the transfer assembly, more exactly the transfer roll?


  2. 05-26-2015


    #2

    Re: xerox 5222 — 077-101

    Hi,
    Check Drum drive coupling and transport roll housing, had a dozen with cracked plastic holders.
    Clean registration sensor if dirty.

    Defects are simple, our mind is complicated


  3. 05-26-2015


    #3

    savi0r is offline


    Senior Tech

    250+ Posts


    Rep Power
    0

    Re: xerox 5222 — 077-101

    They’re all good. Registration assy maybe?


  4. 05-27-2015


    #4

    Re: xerox 5222 — 077-101

    De ce nu vorbiti voi romaneste ?
    Clutch-ul de registratie l-ai schimbat sau curatat ?


  5. 05-27-2015


    #5

    savi0r is offline


    Senior Tech

    250+ Posts


    Rep Power
    0

    Re: xerox 5222 — 077-101

    Salut. Deci, doar l-am curatat. Ieri a mers aparatul, azi iar 077-101 si 077-106. Deja ma scoate din sarite. Aveti idee de unde as putea sa iau un ansamblu d-asta? 90% dintre erori sunt 077-101.


  6. 05-27-2015


    #6

    savi0r is offline


    Senior Tech

    250+ Posts


    Rep Power
    0

    Re: xerox 5222 — 077-101

    Aveam un ansamblu ok, luat de pe alt aparat. Se poate sa fi gresit eu la montaj, ca tot in 077-106 ma tinea, pe ambele aparate. Ma gandeam acu, oare sa iau ambreiajul de pe asta si sa-l pun pe ansamblul de registratie unde am eroare de 077-101? Ce se defecteaza la ele? Ambreiajul sau altceva?


  7. 05-27-2015


    #7

    Re: xerox 5222 — 077-101

    Se uzeaza clutch-ul si patineaza dupa care apar intarzieri.
    Poti pune si clutch de C118 daca ai la indemana, am testat asta si e ok.

    Defects are simple, our mind is complicated


  8. 05-27-2015


    #8

    savi0r is offline


    Senior Tech

    250+ Posts


    Rep Power
    0

    Re: xerox 5222 — 077-101

    Este vreun aspect la montaj mai aparte? Adica clutch luat de pe aparat cu 60k copii nu mai vrea sa mearga nici cum. Odata, dupa ce l-am montat si dezmontat de enspe ori, a scos o foaie. Poate nu fac eu ceva ok.


  9. 05-27-2015


    #9

    Re: xerox 5222 — 077-101

    Uita-te daca clutch-ul de registratie cupleaza. Daca da vezi cum se aseaza rolele de la ansamblul de transfer de pe capacul din stinga — acolo unde este BTR-ul. Cred ca ai ansamblul acela defect si rolele nu calca corect pe rolele de registratie de pe masina.


  10. 05-27-2015


    #10

    savi0r is offline


    Senior Tech

    250+ Posts


    Rep Power
    0

    Re: xerox 5222 — 077-101

    Daca misc senzorul de registratie cu mana, vad cum se invart rolele. Deci eu zic ca registratia ar fi buna. Si masina mergea inainte. Tot cu aceleasi ansamble de registratie si transfer. Ceva nu fac eu bine, cred.


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

BSD-ON:8.7

After the Registration Clutch turned On, the Registration Sensor did not turn Off within the

specified time.

Initial Actions

Power OFF/ON

Procedure

Check the Transport Roll for wear and paper powder. The Transport Roll is ok.

Y

N

Replace the Transport Roll.

Check for foreign substances, distortion and paper powder in the paper transport path. No

distortion, foreign substances, or paper powder are found in the paper transport path.

Y

N

Clear away the foreign substances and paper powder. Correct the distortion.

Execute

Component Control

[089-100 Registration Sensor]. Manually activate the actuator of

the Registration Sensor

(PL

2.4). The display changes.

Y

N

Check the connection of

P/J104

and P/J403.

rectly.

Y

N

Connect

P/J104

and P/J403.

Check the wire between J104 and J403 for an open circuit or a short circuit (BSD 8.7

1/Flag

2). The wire between J104 and J403 is conducting without an open circuit or

a short circuit.

Y

N

Repair the open circuit or short circuit.

Measure the voltage between the MCU PWB P403B-13 (+) and GND (-) (BSD 8.7

2). The voltage is approx. +5VDC.

Y

N

Replace the MCU PWB

(PL

9.1).

Measure the voltage between the MCU PWB P403B-8 (+) and GND (-) (BSD 8.7

Actuate the Registration Sensor with paper. The voltage changes.

Y

N

Replace the Registration Sensor

Replace the MCU PWB

(PL

9.1).

Execute

Component Control

[089-002 Registration Clutch ON]. The Registration Clutch

2.4) can be heard.

Y

N

Check the connection of

P/J215

and P/J403.

rectly.

A

Launch Version

WorkCentre 5225, 5230

P/J104

and

P/J403

are connected cor-

(PL

2.4).

P/J215

and

P/J403

are connected cor-

A

Y

N

Connect

P/J215

and P/J403.

Measure the resistance of the Registration Clutch

(BSD 8.7

Flag

3). The resistance is approx. 240Ohm.

Y

N

Replace the Registration Clutch

Check the wire between J215 and J403 for an open circuit or a short circuit (BSD 8.7

3). The wire between J215 and J403 is conducting without an open circuit or a short

circuit.

Y

N

Repair the open circuit or short circuit.

Replace the MCU PWB

Replace the MCU PWB

(PL

9.1).

Flag

Flag

Flag

1).

(PL

February, 2008

2-543

(PL

2.4) between P215-1 and P215-2

(PL

2.4).

(PL

9.1).

Flag

Status Indicator Raps

077-101

077-101, 077-900 Registration Sensor Jam RAP

BSD-ON: BSD 8.5 Registration

077-101 The trail edge of the paper does not deactuate the registration sensor within the specified time after the registration clutch is energized.
077-900 The registration sensor detected remaining paper.

Initial Actions

• Check the condition of the paper in all trays. Refer to GP 15 Paper and Media Size Specifications.
• Ensure that all the trays are loaded correctly.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.

Perform the steps that follow:

1. Check for obstructions in the paper path.
2. Check the registration roll and takeaway roll 1, PL 80.55 for foreign substances or wear. Clean or install new components as necessary.
3. Enter dC330, code 077-104. Check the registration sensor, PL 80.55 Item 4.
4. Enter dC330, code 042-003. Check the main motor, PL 40.10 Item 10.
5. Enter dC330, code 077-002. Check the registration clutch, PL 80.55 Item 11.
6. Check the drive assembly, PL 40.10 Item 1 for wear or damage.
7. Check the registration transport assembly, PL 80.55 Item 1 for wear or damage.
8. If the fault persists, install new components as necessary:

• Drive PWB, PL 1.10 Item 3.
• ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

077-101, 077-900 Registration Sensor Jam RAP

BSD-ON: BSD 8.5 Registration

077-101 The trail edge of the paper does not deactuate the registration sensor within the specified time after the registration clutch is energized.
077-900 The registration sensor detected remaining paper.

Initial Actions

• Check the condition of the paper in all trays. Refer to GP 15 Paper and Media Size Specifications.
• Ensure that all the trays are loaded correctly.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.

Perform the steps that follow:

1. Check for obstructions in the paper path.
2. Check the registration roll and takeaway roll 1, PL 80.55 for foreign substances or wear. Clean or install new components as necessary.
3. Enter dC330, code 077-104. Check the registration sensor, PL 80.55 Item 4.
4. Enter dC330, code 042-003. Check the main motor, PL 40.10 Item 10.
5. Enter dC330, code 077-002. Check the registration clutch, PL 80.55 Item 11.
6. Check the drive assembly, PL 40.10 Item 1 for wear or damage.
7. Check the registration transport assembly, PL 80.55 Item 1 for wear or damage.
8. If the fault persists, install new components as necessary:

• Drive PWB, PL 1.10 Item 3.
• ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

BSD-ON:8.7

After the Registration Clutch turned On, the Registration Sensor did not turn Off within the

specified time.

Initial Actions

Power OFF/ON

Procedure

Check the Transport Roll for wear and paper powder. The Transport Roll is ok.

Y

N

Replace the Transport Roll.

Check for foreign substances, distortion and paper powder in the paper transport path. No

distortion, foreign substances, or paper powder are found in the paper transport path.

Y

N

Clear away the foreign substances and paper powder. Correct the distortion.

Execute

Component Control

[089-100 Registration Sensor]. Manually activate the actuator of

the Registration Sensor

(PL

2.4). The display changes.

Y

N

Check the connection of

P/J104

and P/J403.

rectly.

Y

N

Connect

P/J104

and P/J403.

Check the wire between J104 and J403 for an open circuit or a short circuit (BSD 8.7

1/Flag

2). The wire between J104 and J403 is conducting without an open circuit or

a short circuit.

Y

N

Repair the open circuit or short circuit.

Measure the voltage between the MCU PWB P403B-13 (+) and GND (-) (BSD 8.7

2). The voltage is approx. +5VDC.

Y

N

Replace the MCU PWB

(PL

9.1).

Measure the voltage between the MCU PWB P403B-8 (+) and GND (-) (BSD 8.7

Actuate the Registration Sensor with paper. The voltage changes.

Y

N

Replace the Registration Sensor

Replace the MCU PWB

(PL

9.1).

Execute

Component Control

[089-002 Registration Clutch ON]. The Registration Clutch

2.4) can be heard.

Y

N

Check the connection of

P/J215

and P/J403.

rectly.

A

Launch Version

WorkCentre 5225, 5230

P/J104

and

P/J403

are connected cor-

(PL

2.4).

P/J215

and

P/J403

are connected cor-

A

Y

N

Connect

P/J215

and P/J403.

Measure the resistance of the Registration Clutch

(BSD 8.7

Flag

3). The resistance is approx. 240Ohm.

Y

N

Replace the Registration Clutch

Check the wire between J215 and J403 for an open circuit or a short circuit (BSD 8.7

3). The wire between J215 and J403 is conducting without an open circuit or a short

circuit.

Y

N

Repair the open circuit or short circuit.

Replace the MCU PWB

Replace the MCU PWB

(PL

9.1).

Flag

Flag

Flag

1).

(PL

February, 2008

2-543

(PL

2.4) between P215-1 and P215-2

(PL

2.4).

(PL

9.1).

Flag

Status Indicator Raps

077-101

Модератор: vetal


Прилепить пост

Сообщение pc-porta » Чт июл 10, 2014 1:17 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

Gregor писал(а):Доброго времени суток. Собственно проблема обозначена в заголовке( Замятий нет, все датчики в норме, такое у меня ощущение, что беда с прошивкой. Подскажите, кто чем может.

здравствуйте . а ,если не секрет, датчики как проверяли ? Визуально или всё-таки тестером ?

Аватар пользователя

pc-porta

Форумный оракул

  • Не в сети
  • Персональный альбом

Прилепить пост

Сообщение Gregor » Чт июл 10, 2014 1:22 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Честно говоря, проверял визуально, ибо принтер почти новый, подумалось — чего им будет, их обычно выворачивают, вот и осмотрел на предмет «механики» их работы. Думаете стоит тестером проверить?

Добавлено спустя 53 минуты 17 секунд:
Xerox 6015 ошибка 077-900 откройте заднюю крышку, устраните

pc-porta писал(а):

Gregor писал(а):Доброго времени суток. Собственно проблема обозначена в заголовке( Замятий нет, все датчики в норме, такое у меня ощущение, что беда с прошивкой. Подскажите, кто чем может.

здравствуйте . а ,если не секрет, датчики как проверяли ? Визуально или всё-таки тестером ?

Датчики проверил тестером, все нормально. А вот полезу ка я ещё раз в печку.

Аватар пользователя

Gregor

Подошел к чернилам

  • Не в сети




Прилепить пост

Сообщение pc-porta » Вт сен 22, 2015 6:55 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

maverick4788 писал(а):Да и я уже разобрался, все оказалось проще…бумажко в печке, небольшой клочок,сперва не заметил.

ага — ага . так и у ми было … :-ok-:

Аватар пользователя

pc-porta

Форумный оракул

  • Не в сети
  • Персональный альбом


  • Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»

    kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4

    5
    5299

    3100
    Перейти к последнему сообщению
    Пн ноя 18, 2019 8:24 pm
  • Xerox WC 3119: «Замятие 1»

    kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4

    22
    38583

    kokubenko
    Перейти к последнему сообщению
    Ср ноя 23, 2011 4:47 pm
  • Xerox 3428 «Установите Картридж»

    Roller-ch в форуме Принтеры, МФУ, факсы, копиры формата A4

    6
    9317

    SeMi
    Перейти к последнему сообщению
    Сб авг 27, 2011 6:42 pm
  • «Неисправность» финишера Xerox 7556

    v1684 в форуме Принтеры, МФУ, копиры формата A3

    21
    12636

    v1684
    Перейти к последнему сообщению
    Ср сен 19, 2018 4:44 pm
  • Xerox 3315 «слетела» FIX прошивка

    tekknik в форуме Принтеры, МФУ, факсы, копиры формата A4

    7
    6834

    tekknik
    Перейти к последнему сообщению
    Пн июн 10, 2019 4:22 am

Вернуться в Принтеры, МФУ, факсы, копиры формата A4

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 106

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

077-101, 077-900 Registration Sensor Jam RAP

BSD-ON: BSD 8.5 Registration

077-101 The trail edge of the paper does not deactuate the registration sensor within the specified time after the registration clutch is energized.
077-900 The registration sensor detected remaining paper.

Initial Actions

• Check the condition of the paper in all trays. Refer to GP 15 Paper and Media Size Specifications.
• Ensure that all the trays are loaded correctly.

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

Refer to the procedures that follow as necessary:

• GP 6 How to Check a Motor.
• GP 7 How to Check a Sensor.

Perform the steps that follow:

1. Check for obstructions in the paper path.
2. Check the registration roll and takeaway roll 1, PL 80.55 for foreign substances or wear. Clean or install new components as necessary.
3. Enter dC330, code 077-104. Check the registration sensor, PL 80.55 Item 4.
4. Enter dC330, code 042-003. Check the main motor, PL 40.10 Item 10.
5. Enter dC330, code 077-002. Check the registration clutch, PL 80.55 Item 11.
6. Check the drive assembly, PL 40.10 Item 1 for wear or damage.
7. Check the registration transport assembly, PL 80.55 Item 1 for wear or damage.
8. If the fault persists, install new components as necessary:

• Drive PWB, PL 1.10 Item 3.
• ESS PWB, PL 3.10 Item 6.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782