Thanks: 0
Likes: 0
Dislikes: 0
-
02-11-2014
#1
Senior Tech
250+ Posts
- Rep Power
- 0
xerox 5225 error code 016-210
I have a problem with this copier. what can I do to solve it? thanks.
-
02-12-2014
#2
Re: xerox 5225 error code 016-210
Originally Posted by javier4065
I have a problem with this copier. what can I do to solve it? thanks.
Put back into machine the device option that is missing.
Or you can clear all machine options and after that reload the options do you have.
-
02-12-2014
#3
Senior Tech
250+ Posts
- Rep Power
- 0
Re: xerox 5225 error code 016-210
Originally Posted by adriansto
Put back into machine the device option that is missing.
Or you can clear all machine options and after that reload the options do you have.Thanks for your help .How can I enter to service mode to cancell the hdd options.
-
02-12-2014
#4
Re: xerox 5225 error code 016-210
Entering UI Diagnostics
- At the Control Panel, press and hold the 0 key for 6 seconds, then press the Start button while still pressing the 0 key.
The CE — Passcode screen will appear. - Enter the Access Number 6789 and press Confirm.
The colors on the display are reversed to indicate that UI Diagnostics mode is active.
Accessing Diagnostic routines
- Press the Machine Status button on the Control Panel.
- Select the Tools tab on the UI.
- Under Features column, use the down arrow and scroll to and select Maintenance / Diagnostics.
Procedure
- Access Diagnostic Routines.
- Enter UI Diagnostics ( UI Diagnostic Mode).
- Select Sub System.
- Select Initialize Hard Disk and select Partition A.
- Press the Start button and select Yes.
- When Partition A has been initialized is displayed, select Confirm
- Access Diagnostic Routines.
- At the Control Panel, press and hold the 0 key for 6 seconds, then press the Start button while still pressing the 0 key.
-
02-15-2014
#5
Trusted Tech
50+ Posts
- Rep Power
- 22
Re: xerox 5225 error code 016-210
put in the hdd will be ok….
Bookmarks
Bookmarks
Posting Permissions
- You may not post new threads
- You may not post replies
- You may not post attachments
- You may not edit your posts
- BB code is On
- Smilies are On
- [IMG] code is On
- [VIDEO] code is On
- HTML code is Off
Forum Rules
One of the Software option functions cannot be executed due to a HDD error or the HDD is not
installed.
Initial Actions
Power Off/On
Procedure
Check HDD electrical connections
(PL
9.2).
If the problem persists perform
Hard Disk Diagnostic
If the problem persists, replace the HDD
Launch Version
WorkCentre 5225, 5230
Program.
(PL
9.2).
016-211 Software Option (System Memory Low) RAP
One of the Software option functions cannot be executed due to insufficient System Memory
capacity.
Initial Actions
Power Off/On
Procedure
Refer customer to following User Guide headings to check memory usage:
•
Allocate Memory
•
Memory Settings
•
Covers
•
Mailbox Screen
•
Properties
•
Properties Features
•
Data Encryption
•
Memory Full Procedure
•
Maximum Stored Pages
February, 2008
2-157
Status Indicator Raps
016-210, 016-211
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
15 Устранение неисправностей
432
013-210
013-211
013-212
013-213
013-220
Неисправен финишер. Выключите и снова включите аппарат. Если
неисправность не устраняется, обратитесь на горячую линию Xerox.
016-210
016-211
016-212
016-213
016-214
016-215
016-216
016-217
016-218
016-219
016-220
016-221
016-222
016-223
016-224
016-225
016-226
016-227
016-228
016-229
016-230
016-231
016-232
016-240
Ошибка при использовании программного обеспечения. Выключите
и снова включите аппарат. Если неисправность не устраняется, обратитесь
на горячую линию Xerox.
016-324
Выполняется перезапись данных на жестком диске. Дождитесь
завершения обработки. Чтобы отменить обработку, выключите и снова
включите аппарат.
016-400
Ошибка идентификации 802.1x. На аппарате неправильно задано имя
пользователя или пароль, либо на сервере идентификации неверные
настройки переключения.
016-401
Выбранный на аппарате метод идентификации 802.1x не поддерживается
сервером идентификации. Измените метод идентификации 802.1x на
панели управления.
016-402
Ошибка таймаута соединения между аппаратом и сервером
идентификации 802.1x. Проверьте соединение между аппаратом и
сервером идентификации.
016-403
Ошибка сертификата идентификации 802.1x. Корневой сертификат для
сертификата сервера идентификации не установлен на аппарате или он
недействительный. Импортируйте на аппарат действительный корневой
сертификат. Или установите для настройки [Проверка сертификата
сервера] опцию [Отключено].
016-404
Ошибка идентификации 802.1x. Попробуйте еще раз. Если неисправность
не устраняется, обратитесь на горячую линию Xerox.
016-450
Хост SMB с таким именем уже существует. Измените имя хоста.
Код
Описание и меры по устранению
Во время работы с аппаратом могут возникать проблемы, связанные с неисправностями «железа» или ПО. И если расходные материалы можно просто заменить, то с «мозгами» нужно разбираться. Поэтому, для экономии времени и удобства, ниже представлены возможные коды ошибок (FAULT ERROR CODE), которые показывают Xerox DocuColor DC 240/250/242/252/260 и WorkCentre WC 7655/7665/7675/7755/7765/7775 при неисправности, и их значение:
002-770 ERROR — RAP Insufficient HDD capacity while processing the job template within a job.
003-318 ERROR — RAP IIT software failure.
003-319 ERROR — RAP IIT Video Driver Detection Fail.
003-320 ERROR — RAP IIT-ESS Communication Fail 1.
003-321 ERROR — RAP IIT-ESS Communication Fail 2.
003-322 ERROR — RAP IIT-ESS Communication Fail 3.
003-323 ERROR — RAP IIT-ESS Communication Fail 4.
003-324 ERROR — RAP IIT-ESS Communication Fail 5.
003-325 ERROR — RAP IIT-ESS Communication Fail 6.
003-326 ERROR — RAP IIT-ESS Communication Fail 7.
003-327 ERROR — RAP IIT-ESS Communication Fail 8.
003-328 ERROR — RAP IIT-ESS Communication Fail 9.
003-329 ERROR — RAP IIT-ESS Communication Fail 10.
003-330 ERROR — RAP IIT-ESS Communication Fail 11.
003-331 ERROR — RAP IIT-ESS Communication Fail 12.
003-332 ERROR — RAP IIT-ESS Communication Fail 13.
003-333 ERROR — RAP IIT-ESS Communication Fail 14.
003-334 ERROR — RAP IIT-ESS Communication Fail 15.
003-335 ERROR — RAP IIT-ESS Communication Fail 16.
003-336 ERROR — RAP IIT-ESS Communication Fail 17.
003-337 ERROR — RAP IIT-ESS Communication Fail 18.
003-338 ERROR — RAP IIT-ESS Communication Fail 19.
003-339 ERROR — RAP IIT-ESS Communication Fail 20.
003-340 ERROR — RAP IIT-ESS Communication Fail 21.
003-341 ERROR — RAP IIT-ESS Communication Fail 22.
003-342 ERROR — RAP IIT-ESS Communication Fail 23.
003-343 ERROR — RAP IIT-ESS Communication Fail 24.
003-344 ERROR — RAP Power on hotline failure.
003-345 ERROR — RAP X PIO Unmatch Fail 1.
003-346 ERROR — RAP X PIO Unmatch Fail 2.
003-750 ERROR — RAP Book Duplex-Insufficient Docs.
003-751 ERROR — RAP Under PANTHER Capacity (Scan).
003-752 ERROR — RAP This status code is displayed if 600dpi cannot be scanned (DADF).
003-753 ERROR — RAP This status code is displayed if over 300dpi cannot be scanned (DADF).
003-754 ERROR — RAP S2X Recoverable Error.
003-755 ERROR — RAP S2X Command Error.
003-757 ERROR — RAP This status code is displayed if over 400dpi cannot be scanned (DADF).
003-760 ERROR — RAP Scan Settings Error.
003-761 ERROR — RAP Incorrect Paper Tray Size.
003-763 ERROR — RAP Adjustment Chart Not Found.
003-764 ERROR — RAP Adjustment Chart Not Found.
003-780 ERROR — RAP Scan Image Compression Error.
003-795 ERROR — RAP AMS Limit Error.
003-940 ERROR — RAP DAM Memory is insufficient.
003-942 ERROR — RAP Document Size Error.
003-944 ERROR — RAP Image Repeat Count Fail.
003-946 ERROR — RAP Copy Vertical/Horizontal Difference (APS).
003-947 ERROR — RAP Replaced Original Count Error.
003-948 ERROR — RAP Replaced Original Mismatch.
003-952 ERROR — RAP Return Documents Color mismatch.
003-955 ERROR — RAP Documents Size Exchange Error.
003-956 ERROR — RAP Documents Size Unknown Error.
003-963 ERROR — RAP No APS Object Tray.
003-965 ERROR — RAP ATS/APS No Paper. There is no paper in the trays that can be selected with APS.
003-966 ERROR — RAP AATS/APS No Destination Error.
003-968 ERROR — RAP Punch Position Error.
003-969 ERROR — RAP Punch Size Error.
003-972 ERROR — RAP Maximum Stored Page Over Flow.
003-973 ERROR — RAP Every Direction Difference.
003-974 ERROR — RAP Next Original Specification.
003-977 ERROR — RAP Document Miss Match (Multi Scan).
003-978 ERROR — RAP Color Document Mismatch (Multi Scan).
003-980 ERROR — RAP Staple Position Error.
003-981 ERROR — RAP Staple Size Error.
003-982 ERROR — RAP IITsc HDD Access Error.
005-121 ERROR — RAP DADF Feed Sensor ON Jam.
005-122 ERROR — RAP DADF Simplex/Side 1 Pre Reg Sensor ON Jam.
005-123 ERROR — RAP DADF Simplex/Side 1 Reg Sensor ON Jam.
005-124 ERROR — RAP DADF Lead Reg Sensor ON Jam.
005-125 ERROR — RAP DADF Reg Sensor OFF Jam.
005-126 ERROR — RAP DADF Out Sensor ON Jam.
005-127 ERROR — RAP DADF Out Sensor OFF Jam.
005-128 ERROR — RAP DADF Exit Sensor 1 ON Jam (Simplex Mode).
005-129 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Simplex Mode).
005-130 ERROR — RAP DADF Invert Sensor ON Jam (Duplex Mode).
005-131 ERROR — RAP DADF Invert Sensor On Jam (Inverting).
005-132 ERROR — RAP DADF Invert SNR on Jam 2.
005-133 ERROR — RAP DADF Invert Sensor OFF Jam.
005-134 ERROR — RAP DADF Invert SNR off Jam (Inv).
005-135 ERROR — RAP DADF Pre Reg Sensor ON Jam (Invert).
005-136 ERROR — ERROR — RAP DADF Reg Sensor ON Jam (Invert).
005-137 ERROR — RAP DADF Exit Sensor 2 ON Jam.
005-138 ERROR — RAP DADF Exit Sensor 1 ON Jam.
005-139 ERROR — RAP DADF Invert SNR off Jam.
005-141 ERROR — RAP DADF Feed Sensor OFF Jam.
005-142 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Duplex Mode).
005-143 ERROR — RAP DADF Exit Sensor 2 OFF Jam.
005-144 ERROR — RAP DADF Too First Pre Reg Sensor ON Jam.
005-145 ERROR — RAP DADF Reg Sensor Off Jam (Invert).
005-146 ERROR — RAP DADF Pre Reg Sensor Off Jam.
005-147 ERROR — RAP DADF Pre Reg Sensor Off Jam (Invert).
005-150 ERROR — RAP DADF Feed Sensor OFF Jam (Perforated Original Mode).
005-151 ERROR — RAP DADF Pre Reg Sensor OFF Jam (Perforated Original Mode).
005-152 ERROR — RAP DADF Reg Sensor OFF Jam (Perforated Original Mode).
005-153 ERROR — RAP DADF Reg Sensor OFF Jam (Perforated Original Mode).
005-154 ERROR — RAP DADF Out Sensor OFF Jam (Perforated Original Mode).
005-155 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Perforated Original Mode) (Simplex).
005-156 ERROR — RAP DADF Exit Sensor 1 OFF Jam (Perforated Original Mode) (Duplex).
005-157 ERROR — RAP DADF Invert Sensor OFF Jam (Perforated Original Mode).
005-158 ERROR — RAP DADF Exit Sensor 2 OFF Jam (Perforated Original Mode).
005-160 ERROR — RAP DADF Tray Lift Up Fail (Document Set) (Within Job).
005-190 ERROR — RAP DADF Feed Motor Logic Jam.
005-194 ERROR — RAP Size Mismatch Jam on Slow Scan Mix Size.
005-195 ERROR — RAP Size Mismatch Jam on No Mix Size.
005-196 ERROR — RAP Size Mismatch Jam on No Mix Size.
005-197 ERROR — RAP Prohibit Combine Size Jam.
005-198 ERROR — RAP Too Short Size Jam.
005-199 ERROR — RAP Too Long Size Jam.
005-275 ERROR — RAP DADF RAM Fail.
005-280 ERROR — RAP DADF EEPROM Fail.
005-282 ERROR — RAP DADF Tray Lift Up Fail (No Document).
005-283 ERROR — RAP DADF Stack Height Sensor Logic Fail.
005-284 ERROR — RAP DADF APS Sensor Logic Fail.
005-285 ERROR — RAP DADF Nudger Lift Up Fail.
005-286 ERROR — RAP DADF Feed Out Sensor Fail.
005-303 ERROR — RAP DADF Tray Interlock is open.
005-304 ERROR — RAP Platen Interlock Open.
005-305 ERROR — RAP DADF Feeder Cover Interlock Open (Run).
005-306 ERROR — RAP DADF Tray Interlock Open (Run).
005-308 ERROR — RAP The DADF L/H Cover Interlock is open.
005-309 ERROR — RAP DADF L/H Cover Interlock Open (Run).
005-906 ERROR — RAP DADF Feed Sensor Static Jam.
005-907 ERROR — RAP DADF Pre Reg Sensor Static Jam.
005-908 ERROR — RAP DADF Reg Sensor Static Jam.
005-909 ERROR — RAP DADF Lead Reg Sensor Static Jam..
005-910 ERROR — RAP DADF Out Sensor Static Jam.
005-911 ERROR — RAP DADF Exit Sensor 1 Static Jam.
005-912 ERROR — RAP DADF Exit Sensor 2 Static Jam.
005-913 ERROR — RAP DADF Invert Sensor Static Jam.
005-914 ERROR — RAP DADF No. 1/2/3 APS Sensor Static Jam.
005-915 ERROR — RAP DADF No. 1 APS Sensor Static Jam.
005-916 ERROR — RAP DADF No. 2 APS Sensor Static Jam.
005-917 ERROR — RAP DADF No. 3 APS Sensor Static Jam.
005-918 ERROR — RAP DADF Invert Sensor 2 Static Jam.
005-919 ERROR — RAP DADF Tray Lift Up Fail (Document Set).
005-940 ERROR — RAP DADF No Original Fail.
005-941 ERROR — RAP DADF Not Enough Document.
005-942 ERROR — RAP DADF Tray Stack Over Fail.
010-311 ERROR — RAP Fuser Heat Roll STS-1 Disconnection Fail. It was detected that fuser heat roll STS-1 disconnected.
010-319 ERROR — RAP Fuser NC Sensor Differential Amp Fail.
010-320 ERROR — RAP Heat Roll Over Heat Fail.
010-321 ERROR — RAP Fuser Nip Fail.
010-322 ERROR — RAP Fuser NC Center Sensor Disconnection Fail. (Fuser Temperature Sensor Fail).
010-323 ERROR — RAP Fuser Rear Sensor Disconnection Fail. (Fuser Temperature Sensor Fail).
010-324 ERROR — RAP Fuser NVM Fail.
010-326 ERROR — RAP Wait Heat Roll Fuser On Time Fail.
010-327 ERROR — RAP Standby Heat Roll Fuser On Time Fail.
010-330 ERROR — RAP Fuser Motor Fail.
010-420 ERROR — RAP Fuser Assembly Life Near End.
010-421 ERROR — RAP Fuser Assembly Life End.
012-112 ERROR — RAP Finisher Interface Entrance Sensor ON.
012-113 ERROR — RAP Booklet In Sensor ON Jam.
012-114 ERROR — RAP Booklet In Sensor OFF Jam.
012-115 ERROR — RAP Booklet Folder Roll Exit Sensor ON Jam.
012-125 ERROR — RAP Gate Sensor ON JAM: Finisher.
012-132 ERROR — RAP Finisher Transport Entrance Sensor ON Jam (Long).
012-142 ERROR — RAP Buffer Path Sensor ON Jam A.
012-151 ERROR — RAP Compile Exit Sensor OFF Jam.
012-152 ERROR — RAP Compile Exit Sensor ON Jam A.
012-161 ERROR — RAP Set Eject Jam.
012-162 ERROR — RAP Finisher Interface EXIT. Sensor ON Jam.
012-171 ERROR — RAP Top Tray Exit Sensor ON Jam A.
012-172 ERROR — RAP Top Tray Exit Sensor OFF Jam A.
012-180 ERROR — RAP Booklet Folder Roll Exit Sensor OFF Jam.
012-211 ERROR — RAP Stacker Tray Fail.
012-212 ERROR — RAP Stacker Tray Upper Limit Fail.
012-213 ERROR — RAP Stacker Tray Lower Limit Fail.
012-221 ERROR — RAP Tamper Home Sensor ON Fail.
012-223 ERROR — RAP Tamper Home Sensor OFF Fail.
012-224 ERROR — RAP Rear Tamper Home Sensor OFF Fail.
012-225 ERROR — RAP Booklet Tamper F Home Sensor ON Fail.
012-226 ERROR — RAP Booklet Tamper F Home Sensor OFF Fail.
012-227 ERROR — RAP Booklet End Guide Home Sensor OFF Fail.
012-228 ERROR — RAP Booklet End Guide Home Sensor ON Fail.
012-229 ERROR — RAP Booklet Tamper R Home Sensor ON Fail.
012-230 ERROR — RAP Booklet Tamper R Home Sensor OFF Fail.
012-243 ERROR — RAP Booklet Knife Home Sensor ON Fail.
012-246 ERROR — RAP Booklet Stapler Fail.
012-247 ERROR — RAP Side Regi Sensor OFF Fail.
012-260 ERROR — RAP Eject Clamp Up Sensor ON Fail.
012-261 ERROR — RAP Booklet Knife Folding SNR Fail.
012-263 ERROR — RAP Finisher Rear Tamper Home Sensor ON.
012-264 ERROR — RAP Booklet Drawer Broken Fail.
012-265 ERROR — RAP Booklet Knife Home Sensor OFF Fail.
012-266 ERROR — RAP Booklet Compiler No Paper Sensor Fail.
012-270 ERROR — RAP Top Offset Home Sensor ON Fail: Finisher.
012-271 ERROR — RAP Top Offset Home Sensor OFF Fail: Finisher.
012-282 ERROR — RAP Eject Clamp Up Sensor OFF Fail.
012-283 ERROR — RAP Finisher Set Clamp Home Sensor ON Fail.
012-284 ERROR — RAP Finisher Set Clamp Home Sensor OFF Fail.
012-291 ERROR — RAP Stapler Fail.
012-295 ERROR — RAP Finisher Stapler Move Sensor On Fail.
012-296 ERROR — RAP Finisher Stapler Move Sensor OFF Fail.
012-300 ERROR — RAP Finisher Eject Cover Open (Compiler Cover).
012-302 ERROR — RAP Finisher Front Door Interlock Open.
012-307 ERROR — RAP Booklet Drawer Set Fail.
012-320 ERROR — RAP Punch Home Sensor ON Fail.
012-321 ERROR — RAP Punch Home Sensor OFF Fail.
012-322 ERROR — RAP Puncher Move Home Sensor OFF Fail.
012-323 ERROR — RAP Puncher Move Home Sensor On Fail.
012-325 ERROR — RAP Side Regi Home Sensor On Fail.
012-330 ERROR — RAP Decurler Cam Home Sensor OFF Fail.
012-332 ERROR — RAP Decurler Cam Home Sensor ON Fail.
012-334 ERROR — RAP Download Mode Fail.
012-335 ERROR — RAP Booklet Sub CPU Communication Fail.
012-900 ERROR — RAP Buffer Path Sensor Static Jam.
012-901 ERROR — RAP Finisher Paper Remains at H-Transport Entrance.
012-902 ERROR — RAP Finisher Paper Remains H-Transport Exit.
012-903 ERROR — RAP Compile Exit Sensor Static Jam.
012-905 ERROR — RAP Compile Tray No Paper Sensor Static Jam.
012-907 ERROR — RAP Top Tray Exit Sensor Static Jam.
012-920 ERROR — RAP Gate Sensor static JAM (to Top Tray) A: Finisher.
012-932 ERROR — RAP Gate SNR static JAM (to Stacker Tray) A.
012-934 ERROR — RAP Gate SNR static JAM (to Stacker Tray) C.
012-935 ERROR — RAP Finisher Paper Remains at Transport Entrance Sensor.
012-936 ERROR — RAP Paper Remain at Booklet In SNR A.
012-949 ERROR — RAP Finisher Punch DustBox Miss Set.
013-902 ERROR — RAP Booklet Compile No Paper Sensor Static Jam.
013-903 ERROR — RAP Booklet Folder Roll Exit Sensor Static Jam.
016-210 ERROR — RAP Software Option Fail (HDD Not Exist).
016-211 ERROR — RAP Software Option Fail (System Memory Low Volume).
016-212 ERROR — RAP SW Option Fail (Page Memory Low).
016-213 ERROR — RAP SW Option Fail (Printer CARD Not Exist).
016-215 ERROR — RAP SW Option Fail (JPEG Board Not Exist).
016-216 ERROR — RAP SW Option Fail (Ext Memory Not Exist).
016-217 ERROR — RAP SW Option Fail (Controller ROM not Printer kit).
016-218 ERROR — RAP Because PS Kit is not installed, XDOD functions cannot be fulfilled.
016-219 ERROR — RAP License is required (Printer Kit).
016-220 ERROR — RAP S2X Unrecoverable Error.
016-221 ERROR — RAP S2X Communication Error.
016-222 ERROR — RAP S2X Self-Diag Error.
016-223 ERROR — RAP SS2X SDRAM Error.
016-224 ERROR — RAP S2X PCI Reg Error.
016-225 ERROR — RAP S2X ROM CheckSum Error.
016-226 ERROR — RAP S2X IIT Connection Error.
016-227 ERROR — RAP S2X DDR Error.
016-228 ERROR — RAP S2X Image Processing Error.
016-229 ERROR — RAP SW Option Fail (FCW-UI Not Exist).
016-311 ERROR — RAP The scanner was not detected.
016-315 ERROR — RAP NIIT Interface Fail.
016-316 ERROR — RAP Page Memory Not Detected.
016-317 ERROR — RAP Page Memory Broken-Standard.
016-318 ERROR — RAP Page Memory Broken-Option.
016-320 ERROR — RAP A fatal error with doc conversion software was detected.
016-322 ERROR — RAP JBA Account Full.
016-450 ERROR — RAP SMB Host Name Duplicated.
016-454 ERROR — RAP DNS Renewal Failure of Dynamic.
016-455 ERROR — RAP SNTP Server Time Out.
016-456 ERROR — RAP SNTP Time Asynchronous.
016-503 ERROR — RAP SMTP Server Address Resolution Fail.
016-504 ERROR — RAP POP Server Address Resolution Fail.
016-505 ERROR — RAP POP Authentication Fail.
016-600 ERROR — RAP KO Authentication Locked.
016-601 ERROR — RAP Illegal Access Detection.
016-647 ERROR — RAP With APS selected or with APS set up, there were no trays loaded with paper sizes for Auto Paper Selection.
016-648 ERROR — RAP Job with Booklet selected was discontinued because it had a cover with an image, a divider, or a blank page.
016-701 ERROR — RAP Out of ART EX Memory.
016-702 ERROR — RAP Out of Page Buffer.
016-703 ERROR — RAP Email to Invalid Box.
016-704 ERROR — RAP Mailbox is Full.
016-705 ERROR — RAP Secure Print Fail.
016-706 ERROR — RAP Max. User Number Exceeded.
016-707 ERROR — RAP Sample Print Fail.
016-708 ERROR — RAP HD Full by Annotation/Watermark Image.
016-709 ERROR — RAP ART EX Command Error.
016-710 ERROR — RAP Delayed Print Fail.
016-711 ERROR — RAP Tried to send data whose size is over the system data upper limit.
016-712 ERROR — RAP Under PANTHER Capacity (I-Formatter).
016-713 ERROR — RAP Security Box Password Error.
016-714 ERROR — RAP Security Box is not Enabled.
016-716 ERROR — RAP TIFF Data Overflow.
016-718 ERROR — RAP Out of PCL6 Memory.
016-719 ERROR — RAP Out of PCL Memory.
016-720 ERROR — RAP PCL Command Error.
016-721 ERROR — RAP Other Error.
016-722 ERROR — RAP Job Cancel by Staple Position NG.
016-723 ERROR — RAP Job Cancel by Punch Position NG.
016-724 ERROR — RAP Complex Position Error of Staple and Punch.
016-726 ERROR — RAP PDL Auto Switch Fail.
016-728 ERROR — RAP Unsupported TIFF Data.
016-729 ERROR — RAP TIFF Data Size too Big.
016-730 ERROR — RAP Unsupported ART Command.
016-731 ERROR — RAP Invalid TIFF Data.
016-732 ERROR — RAP Form Not Registered.
016-733 ERROR — RAP Destination Address Resolution Error.
016-734 ERROR — RAP Simple Transmission report invocation error.
016-735 ERROR — RAP Updating Job Template.
016-736 ERROR — RAP Remote directory lock error. Lock directory creation failed.
016-737 ERROR — RAP Remote lock directory remove error.
016-738 ERROR — RAP PS Booklet Print Output Paper Size is illegal.
016-739 ERROR — RAP Mismatch between PS Booklet Doc and Output Paper.
016-740 ERROR — RAP PS Booklet Output Tray is incorrect.
016-746 ERROR — RAP Unsupported PDF File.
016-748 ERROR — RAP HD Full.
016-749 ERROR — RAP JCL Syntax Error.
016-751 ERROR — RAP PDF Error.
016-752 ERROR — RAP PDF Short of Memory.
016-753 ERROR — RAP PDF Password Mismatched.
016-754 ERROR — RAP PDF LZW Not Installed.
016-755 ERROR — RAP PDF Print Prohibited.
016-756 ERROR — RAP Auditron-Prohibit Service.
016-757 ERROR — RAP Auditron-Invalid User.
016-758 ERROR — RAP Auditron-Disabled Function.
016-759 ERROR — RAP Auditron-Reached Limit.
016-760 ERROR — RAP PS Decompose Failure.
016-761 ERROR — RAP FIFO Empty.
016-762 ERROR — RAP Print LANG Not Installed.
016-764 ERROR — RAP SMTP Server Connect Error.
016-765 ERROR — RAP SMTP Server HD Full.
016-766 ERROR — RAP SMTP Server File System Error.
016-767 ERROR — RAP Invalid E-mail Address.
016-768 ERROR — RAP Invalid Sender Address.
016-769 ERROR — RAP SMTP Server Unsupported DSN.
016-771 ERROR — RAP Scan Data Repository ERR.
016-772 ERROR — RAP Scan Data Repository ERR.
016-773 ERROR — RAP Invalid IP Address.
016-774 ERROR — RAP HD Full-Compression Convert.
016-775 ERROR — RAP HD Full-Image Convert.
016-776 ERROR — RAP Image Convert ERR.
016-777 ERROR — RAP HD Access ERR-Image Convert.
016-778 ERROR — RAP HD Full-Scan Image Convert.
016-779 ERROR — RAP Scan Image Conversion Error.
016-780 ERROR — RAP HD Access ERR-Image Convert.
016-781 ERROR — RAP Scan Server Connect ERR.
016-782 ERROR — RAP Scan Server Login ERR.
016-783 ERROR — RAP Invalid Server Path.
016-784 ERROR — RAP Server Write ERR.
016-785 ERROR — RAP Server HD Full.
016-786 ERROR — RAP HD Full-Scan Write ERR.
016-787 ERROR — RAP Invalid Server IP ADD.
016-788 ERROR — RAP Retrieve to Browser Failed.
016-789 ERROR — RAP HD Full-Job Memory.
016-791 ERROR — RAP File Retrieve Fail.
016-792 ERROR — RAP Specified Job Not Found.
016-793 ERROR — RAP MF I/O HD Full.
016-794 ERROR — RAP Media Reader: Media No Insert.
016-795 ERROR — RAP Media Reader: Format Error.
016-796 ERROR — RAP Document insert operation error.
016-797 ERROR — RAP Media Reader: Image File Read Error.
016-798 ERROR — RAP No Trust Marking Option.
016-799 ERROR — RAP Print Instruction Fail.
016-940 ERROR — RAP With Duplex Output selected, a size difference between side 1 and side 2 was detected.
016-941 ERROR — RAP With Booklet selected, mixed-in-size/orientation pages with images were detected.
016-942 ERROR — RAP After a duplexed page was deleted, a size difference between side 1 and side 2 was detected.
016-943 ERROR — RAP After a document or divider was inserted, a size difference between side 1 and side 2 was detected.
016-944 ERROR — RAP Documents were merged, including the cover with an image, or a document with a divider.
016-945 ERROR — RAP A document unavailable for duplex print was inserted after a document available for Duplex was inserted.
016-946 ERROR — RAP A document or a divider was inserted after the cover or divider page.
016-949 ERROR — RAP The user inserted a documnet different in size/orientation from the page to be processed.
016-981 ERROR — RAP A failure in access to HDD.
016-982 ERROR — RAP HDD Access Error 2.
016-985 ERROR — RAP Data Size Over Flow (Scan to Email).
024-340 ERROR — RAP IOT-ESS Communication Failure 1.
024-341 ERROR — RAP IOT-ESS Communication Failure 2.
024-342 ERROR — RAP IOT-ESS Communication Failure 3.
024-343 ERROR — RAP IOT-ESS Communication Failure 4.
024-345 ERROR — RAP IOT-ESS Communication Failure 5.
024-346 ERROR — RAP IOT-ESS Communication Failure 6.
024-347 ERROR — RAP IOT-ESS Communication Failure 7.
024-348 ERROR — RAP IOT-ESS Communication Failure 8.
024-349 ERROR — RAP IOT-ESS Communication Failure 9.
024-350 ERROR — RAP IOT-ESS Communication Failure 10.
024-351 ERROR — RAP IOT-ESS Communication Failure 11.
024-352 ERROR — RAP IOT-ESS Communication Failure 12.
024-353 ERROR — RAP IOT-ESS Communication Failure 13.
024-354 ERROR — RAP IOT-ESS Communication Failure 14.
024-355 ERROR — RAP IOT-ESS Communication Failure 15.
024-356 ERROR — RAP IOT-ESS Communication Failure 16.
024-357 ERROR — RAP IOT-ESS Communication Failure 17.
024-358 ERROR — RAP IOT-ESS Communication Failure 18.
024-359 ERROR — RAP IOT-ESS Communication Failure 19.
024-360 ERROR — RAP IOT-ESS Initialization Failure.
024-361 ERROR — RAP Invalid IOT PaperSizeGroup Information.
024-362 ERROR — RAP Page Sync Illegal Start.
024-363 ERROR — RAP Page Sync Illegal Stop.
024-364 ERROR — RAP DMA Transfer Failure.
024-365 ERROR — RAP Overflow on the Loop Back Write.
024-366 ERROR — RAP JBIG Library Other Failure.
024-367 ERROR — RAP Decompress Other Failure.
024-368 ERROR — RAP PCI Error.
024-370 ERROR — RAP Marker Code Detect Failure.
024-371 ERROR — RAP IOT-ESS Communication Failure 21.
024-372 ERROR — RAP IOT-ESS Communication Failure 22.
024-373 ERROR — RAP IOT-ESS Communication Failure 23.
024-374 ERROR — RAP Regi Con PLL Parameter Failure.
024-375 ERROR — RAP IOT-ESS Communication Failure 24.
024-600 ERROR — RAP Billing master counter repair.
024-601 ERROR — RAP Billing backup counter #1 repair.
024-602 ERROR — RAP Billing backup counter #2 repair.
024-603 ERROR — RAP SWKey master counter repair.
024-604 ERROR — RAP SWKey backup counter #1 repair.
024-605 ERROR — RAP SWKey backup counter #2 repair.
024-606 ERROR — RAP Production Number/Serial Number Failure.
024-746 ERROR — RAP Selected Paper Tray Parameter Mismatch.
024-747 ERROR — RAP Print Instruction Failure.
024-910 ERROR — RAP Tray 1 Size Mismatch.
024-911 ERROR — RAP Tray 2 Size Mismatch.
024-912 ERROR — RAP Tray 3 Size Mismatch.
024-913 ERROR — RAP Tray 4 Size Mismatch.
024-914 ERROR — RAP Tray 6 Size Mismatch.
024-915 ERROR — RAP Tray 7 Size Mismatch.
024-917 ERROR — RAP Stacker Tray Staple Set Over Count.
024-919 ERROR — RAP Face UP Tray Close.
024-920 ERROR — RAP Face Down Tray 1 Paper FULL.
024-922 ERROR — RAP Face Down Tray 2 Paper FULL.
024-923 ERROR — RAP Operation Yellow Toner Empty.
024-924 ERROR — RAP Operation Magenta Toner Empty.
024-925 ERROR — RAP Operation Cyan Toner Empty.
024-926 ERROR — RAP Punch Dust Box Missing Set.
024-927 ERROR — RAP Offset Catch Tray Full Stack.
024-930 ERROR — RAP Stacker Tray Full (Small Size Full).
024-934 ERROR — RAP Paper type mismatch.
024-935 ERROR — RAP Tray 1 Paper Mismatch.
024-936 ERROR — RAP Tray 2 Paper Mismatch.
024-937 ERROR — RAP Tray 3 Paper Mismatch.
024-938 ERROR — RAP OHP kind Mismatch at Tray 4 (Not White Frame OHP).
024-939 ERROR — RAP Transparency type mismatch (No white border).
024-940 ERROR — RAP Folder Tray Out of Place.
024-941 ERROR — RAP Folder Tray Full Stack.
024-942 ERROR — RAP Booklet Sheets Over Count.
024-943 ERROR — RAP Booklet Low Staple.
024-945 ERROR — RAP Booklet Full Stack.
024-946 ERROR — RAP Tray 1 Not In Position.
024-947 ERROR — RAP Tray 2 Not In Position.
024-948 ERROR — RAP Tray 3 Not In Position.
024-949 ERROR — RAP Tray 4 Not In Position.
024-950 ERROR — RAP Tray 1 No Paper.
024-951 ERROR — RAP Tray 2 No Paper.
024-952 ERROR — RAP Tray 3 No Paper.
024-953 ERROR — RAP Tray 4 No Paper.
024-954 ERROR — RAP MSI No Paper.
024-955 ERROR — RAP Tray 6 No Paper.
024-956 ERROR — RAP Tray 7 No Paper.
024-957 ERROR — RAP Interposer No Paper.
024-958 ERROR — RAP MSI Size Mismatch.
024-959 ERROR — RAP Tray 1 Paper Size Mismatch.
024-960 ERROR — RAP Tray 2 Paper Size Mismatch.
024-961 ERROR — RAP Tray 3 Paper Size Mismatch.
024-962 ERROR — RAP Tray 4 Paper Size Mismatch.
024-965 ERROR — RAP ATS/APS No Paper.
024-966 ERROR — RAP ATS/APS No Destination Error.
024-967 ERROR — RAP Different Width Mix Paper Detect (Staple Job).
024-968 ERROR — RAP Stapler/Punch Batting.
024-969 ERROR — RAP Different Width Mix Punch.
024-970 ERROR — RAP Tray 6 Not In Position.
024-971 ERROR — RAP Tray 7 Not In Position.
024-972 ERROR — RAP Tray 6 Paper Size Mismatch.
024-973 ERROR — RAP Tray 7 Paper Size Mismatch.
024-974 ERROR — RAP Interposer Tray Size Mismatch.
024-975 ERROR — RAP Booklet Sheets Over Count (Not Field Attachment).
024-976 ERROR — RAP Finisher Staple Status incorrect.
024-977 ERROR — RAP Stapler Feed Ready Failure.
024-978 ERROR — RAP Booklet Stapler incorrect.
024-979 ERROR — RAP Stapler Near Empty.
024-980 ERROR — RAP Finisher Stacker Tray Full.
024-981 ERROR — RAP Finisher Top Tray Full.
024-982 ERROR — RAP Stacker Lower Safety Warning.
024-983 ERROR — RAP Booklet Tray Full.
024-984 ERROR — RAP Booklet Low Staple F.
024-985 ERROR — RAP SMH Stop Check.
024-987 ERROR — RAP Envelope Folder Tray Full.
024-988 ERROR — RAP Envelope Folder Tray Set Failure.
024-989 ERROR — RAP Booklet Low Staple R.
024-990 ERROR — RAP Punch Dust Full.
025-596 ERROR — RAP Diag HDD Failure 1.
025-597 ERROR — RAP Diag HDD Failure 2.
027-452 ERROR — RAP Duplicate IP address.
027-500 ERROR — RAP SMTP Server Address Resolution Failure.
027-501 ERROR — RAP POP Server Address Resolution Failure.
027-502 ERROR — RAP POP Authentication Failure.
027-700 ERROR — RAP Media Failure.
027-701 ERROR — RAP Media Not Found.
027-702 ERROR — RAP Media Data Not Found / Not Supported.
027-703 ERROR — RAP Media Reader Failure / Disconnected.
027-706 ERROR — RAP Certificate not found.
027-707 ERROR — RAP Certificate expired.
027-708 ERROR — RAP Certificate untrusted.
027-709 ERROR — RAP Certificate revoked.
027-710 ERROR — RAP S/MIME mail was disabled.
027-711 ERROR — RAP S/MIME mail sender certificate not found.
027-712 ERROR — RAP S/MIME mail sender certificate not valid.
027-713 ERROR — RAP S/MIME mail was altered.
027-714 ERROR — RAP S/MIME mail sender impersonation.
027-715 ERROR — RAP S/MIME mail certificate not supported.
027-716 ERROR — RAP No-Signed mail receipt was rejected.
027-720 ERROR — RAP Ext Srv. Host Not Found. A server specified for a remote application was not found, or DNS resolution was not possible.
027-721 ERROR — RAP Ext Srv. Not Found.
027-722 ERROR — RAP Ext Srv. Timeout Failure.
027-723 ERROR — RAP Ext Srv. Authentication Failure.
027-724 ERROR — RAP Ext Srv. Access Failure.
027-725 ERROR — RAP Ext Srv. Operation Failure.
027-726 ERROR — RAP Ext Srv. Unknown State.
027-727 ERROR — RAP Ext Srv. Req Invalid Parameters.
027-728 ERROR — RAP Ext Srv. Required File Exceeded.
027-737 ERROR — RAP Template Server Read Error.
027-739 ERROR — RAP Invalid Template Server Path.
027-740 ERROR — RAP Template Server Login Error.
027-741 ERROR — RAP Template Server Connect Failure.
027-742 ERROR — RAP HD File System Full.
027-743 ERROR — RAP Template Server Install Error.
027-744 ERROR — RAP Template Server ADD Error.
027-745 ERROR — RAP Template Server ADD Error.
027-746 ERROR — RAP Job Template Pool Server Not Ready.
027-751 ERROR — RAP Job Template Analysis Error.
027-752 ERROR — RAP Must User un Inputting.
027-753 ERROR — RAP Job Flow Service Request Disabled.
027-760 ERROR — RAP XJT Command Failure.
027-770 ERROR — RAP PDL Error.
027-771 ERROR — RAP DFE Disk Full.
027-796 ERROR — RAP Email Not Printed.
027-797 ERROR — RAP Invalid Output Destination.
042-313 ERROR — RAP Rear Cooling Fan Failure.
042-320 ERROR — RAP Yellow Drum Motor Drive Failure.
042-321 ERROR — RAP Magenta Drum Motor Drive Failure.
042-322 ERROR — RAP Cyan Drum Motor Drive Failure.
042-323 ERROR — RAP Black Drum Motor Drive Failure.
042-324 ERROR — RAP IBT Drive Motor Failure.
042-325 ERROR — RAP Main Motor Failure.
042-326 ERROR — RAP Belt Home Position too long.
042-327 ERROR — RAP Belt Position Failure.
042-328 ERROR — RAP Belt Edge Sensor Failure.
042-330 ERROR — RAP Fuser Exhaust Fan Failure.
042-331 ERROR — RAP Blower Motor Fan Failure.
042-600 ERROR — RAP Belt Walk Failure.
042-601 ERROR — RAP Belt Edge Learn Failure.
042-602 ERROR — RAP Belt Edge Check Failure.
042-603 ERROR — RAP Suction Filter Life End Failure.
045-310 ERROR — RAP Image Ready NG.
045-311 ERROR — RAP Controller Comm Failure.
045-312 ERROR — RAP Driver Connect Failure.
047-210 ERROR — RAP OCT Offset Failure.
047-310 ERROR — RAP MCU-Finisher Communication Failure.
061-310 ERROR — RAP Clapper 1 Failure.
061-311 ERROR — RAP Clapper 2 Failure.
061-313 ERROR — RAP SOS Long Failure Magenta.
061-315 ERROR — RAP SOS Long Failure Black.
061-317 ERROR — RAP SOS Short Failure.
061-319 ERROR — RAP SOS Short Failure Black.
061-320 ERROR — RAP Polygon Motor Failure.
061-321 ERROR — RAP ROS Motor Failure.