CherylO-Xerox
Valued Advisor
- Mark as New
- Bookmark
- Subscribe
- Subscribe to RSS Feed
- Permalink
- Report Inappropriate Content
07-10-2020
07:33 PM
Hi alisons,
Thank you for using the Support Forum. Please take a look at the the suggested solutions for the error 050-142. If this information does not help please consider contacting your support centre for further assistance.
Thanks,
CherylO-Xerox
Community Manager
Be sure to click Kudos for those who have helped you.
Select Accept as Solution for posts that have helped to solve your issue(s)!
0
Kudos
Reply
alisons
New Member
- Mark as New
- Bookmark
- Subscribe
- Subscribe to RSS Feed
- Permalink
- Report Inappropriate Content
07-01-2020
10:23 AM
Error 050-142 paper jam
Product Name: WorkCentre 3615
Operating System: Windows 10 x64
Have followed instructions to clear paper jam. No remains of paper in the machine. Have turned off and turned back on. Screen still shows paper jam error 050-142. Any suggestions on how to fix?
0
Kudos
Reply
Поиск и устр. неиспр.
Застревание бумаги
•
Нахождение застрявшей бумаги ………………………………………………………………………………………………………….. 148
•
•
Извлечение застрявшей бумаги …………………………………………………………………………………………………………… 150
•
Устранение застреваний бумаги ………………………………………………………………………………………………………….. 161
•
Проблемы с качеством печати ……………………………………………………………………………………………………………… 163
•
•
Проблемы при работе с факсом …………………………………………………………………………………………………………… 169
Нахождение застрявшей бумаги
ПРЕДУПРЕЖДЕНИЕ.
во фьюзере. Можно получить ожог. Если лист бумаги намотался на нагревательный вал, не
пытайтесь удалить его сразу. Выключите принтер и подождите 40 минут, пока остынет
фьюзер. После охлаждения принтера попробуйте извлечь застрявшую бумагу. Если ошибку
устранить не удается, обратитесь в представительство Xerox.
ВНИМАНИЕ!
При вытаскивании застрявшей бумаги не пользуйтесь подручными средствами
и инструментами. Это может привести к неустранимому повреждению принтера.
Ниже указаны участки, где может застревать бумага.
1. Лоток 2
2. Дуплексный автоматический податчик оригиналов
3. Фьюзер
148
Многофункциональный черно-белый принтер Xerox
Руководство пользователя
Не касайтесь зоны с наклейками на нагревательном валу и вблизи него
4. Обходной лоток
5. Лоток 1
®
®
WorkCentre
3615
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Поиск и устр. неиспр.
Многофункциональный черно-белый принтер Xerox
®
WorkCentre
®
3615 145
Руководство пользователя
Возможные причины
Решения
Принтер подключен к источнику
бесперебойного питания.
Выключите принтер и вставьте вилку шнура питания в
подходящую розетку.
Принтер подключен к разветвителю
питания вместе с другими
электроприборами большой мощности.
Подключите принтер к розетке напрямую или через
разветвитель питания, к которому не подключены другие
электроприборы большой мощности.
Принтер не печатает
Возможные причины
Решения
Ошибка принтера.
Для сброса ошибки следуйте указаниям на экране. Если ошибку
устранить не удается, обратитесь в представительство Xerox.
В принтере нет бумаги.
Вложите бумагу в лоток.
В картридже закончился тонер.
Замените пустой тонер-картридж.
Мигает индикатор ошибки.
•
Для сброса ошибки следуйте указаниям на экране.
•
Если индикатор готовности не светится, значит работа
принтера прекращена. Выключите и снова включите
принтер. Если ошибку устранить не удается, обратитесь в
представительство Xerox.
Не горят оба индикатора на панели
управления.
Выключите принтер; убедитесь, что шнур питания правильно
вставлен в принтер и в розетку и снова включите принтер. Если
ошибку устранить не удается, обратитесь в представительство
Xerox.
Принтер занят.
•
Если мигает индикатор готовности, то это не ошибка.
Причиной может быть проблема с предыдущей работой
печати. Удалите все работы в очереди печати с помощью
свойств принтера.
•
Загрузите бумагу в лоток.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте Ethernet-подключение между принтером и
компьютером.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте USB-подключение между принтером и
компьютером. Выключите и снова включите принтер.
Кабель принтера не подключен.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте USB-подключение между принтером и
компьютером.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте Ethernet-подключение между принтером и
компьютером.
Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.
-
93b2374f4
- Сообщения: 28
- Стаж: 1 год 1 месяц
- Благодарил (а): 5 раз
- Поблагодарили: 1 раз
-
Репутация:
Xerox WorkCentre 3615 нет бумаги в нижнем лотке
Сообщение
93b2374f4 » 28 июн 2022, 19:51
Добрый день!
Имеется МФУ Xerox WorkCentre 3615
С недавнего времени постоянно показывает ошибку нет бумаги в нижнем лотке (хотя на самом деле она там есть), приходится пользоваться универсальным лотком
Визуальный осмотр ничего не выявил, но если извлечь универсальный лоток и задвинуть нижний лоток, то стопка бумаги не поднимается на прижине, а так и остается лежать в горизонтальном положении, есть предположении, что при задвигании нижнего лотка должен срабатывать надавливанием какой-то «флажок» и стопка бумаги должна подниматься в лотке на пружине
Подскажите парт номер этого флажка или где его заказать можно?
Спасибо!
-
DJON
- Сообщения: 151
- Стаж: 1 год 1 месяц
- Благодарил (а): 3 раза
- Поблагодарили: 9 раз
-
Репутация:
Xerox WorkCentre 3615 нет бумаги в нижнем лотке
Сообщение
DJON » 30 июн 2022, 15:01
Нет у меня таких аппаратов. Но!!! Разве этот флажок отвечает за подъём бумаги в лотке???? Это флажок наличия бумаги, судя по партс каталогу, и он никак не достанет до бумаги пока её не поднять. Соответственно сигнал на подъём бумаги приходит не с этого датчика. Подъём бумаги должен осуществляться не зависимо есть она или нет в лотке и только после подъёма датчик определит есть бумага или нет. Ищите почему у вас не поднимается бумага в лотке.
-
93b2374f4
- Сообщения: 28
- Стаж: 1 год 1 месяц
- Благодарил (а): 5 раз
- Поблагодарили: 1 раз
-
Репутация:
Xerox WorkCentre 3615 нет бумаги в нижнем лотке
Сообщение
93b2374f4 » 30 июн 2022, 22:08
DJON писал(а): ↑30 июн 2022, 15:01
Нет у меня таких аппаратов. Но!!! Разве этот флажок отвечает за подъём бумаги в лотке???? Это флажок наличия бумаги, судя по партс каталогу, и он никак не достанет до бумаги пока её не поднять. Соответственно сигнал на подъём бумаги приходит не с этого датчика. Подъём бумаги должен осуществляться не зависимо есть она или нет в лотке и только после подъёма датчик определит есть бумага или нет. Ищите почему у вас не поднимается бумага в лотке.
Да, действительно, извините я тупанул немного, по факту у меня сломан флажок на «99. Feeder Assembly Kit (REP 2.3)», который и нажимает на кнопку на нижнем лотке для поднятия бумаги, по видимому сильно хлопнули при закрытии нижнего лотка вот его (флажок) и отломило ((
Отправлено спустя 1 день 2 часа 50 минут 40 секунд:
Вот этот флажок сломался (на фото показан красной стрелкой), но вот если покупать комплект серых роликов, то в месте с ними в комплекте не входит эта пластиковая площадка с флажком, и как узнать её парт номер или хотя-бы название неизвестно
-
- 11 Ответы
- 192 Просмотры
- Последнее сообщение
07 ноя 2022, 16:04
-
- 2 Ответы
- 115 Просмотры
- Последнее сообщение
23 сен 2022, 10:01
-
- 7 Ответы
- 203 Просмотры
- Последнее сообщение
24 авг 2022, 15:07
-
- 10 Ответы
- 161 Просмотры
- Последнее сообщение
29 ноя 2022, 10:41
-
- 4 Ответы
- 103 Просмотры
- Последнее сообщение
26 окт 2022, 16:25
Поиск и устр. неиспр.
Застревание бумаги
•
Нахождение застрявшей бумаги ………………………………………………………………………………………………………….. 148
•
•
Извлечение застрявшей бумаги …………………………………………………………………………………………………………… 150
•
Устранение застреваний бумаги ………………………………………………………………………………………………………….. 161
•
Проблемы с качеством печати ……………………………………………………………………………………………………………… 163
•
•
Проблемы при работе с факсом …………………………………………………………………………………………………………… 169
Нахождение застрявшей бумаги
ПРЕДУПРЕЖДЕНИЕ.
во фьюзере. Можно получить ожог. Если лист бумаги намотался на нагревательный вал, не
пытайтесь удалить его сразу. Выключите принтер и подождите 40 минут, пока остынет
фьюзер. После охлаждения принтера попробуйте извлечь застрявшую бумагу. Если ошибку
устранить не удается, обратитесь в представительство Xerox.
ВНИМАНИЕ!
При вытаскивании застрявшей бумаги не пользуйтесь подручными средствами
и инструментами. Это может привести к неустранимому повреждению принтера.
Ниже указаны участки, где может застревать бумага.
1. Лоток 2
2. Дуплексный автоматический податчик оригиналов
3. Фьюзер
148
Многофункциональный черно-белый принтер Xerox
Руководство пользователя
Не касайтесь зоны с наклейками на нагревательном валу и вблизи него
4. Обходной лоток
5. Лоток 1
®
®
WorkCentre
3615
Опыта общения с этими аппаратами у меня немного, но тем не менее решил поделится тем что знаю.
Xerox WorkCentre 3615 DN
Есть на обслуживании клиент с двумя аппаратами Xerox WorkCentre 3615DN аппараты обслуживаем чуть больше года. Сразу скажу, что это не клон Samsung, а собственная разработка Xerox. С одной стороны ролики захвата/отделения совместимы со многими аппаратами Xerox, с другой стороны из за бренда Xerox стоимость на ЗИП зашкаливает. Аппарат не смотря на невысокую стоимость печатает со скоростью 47 страниц в минуту, что для столь низкой цены на аппарат просто удивительно. При печати аппарат из за небольшого веса ощутимо подрагивает, прямо как дешевые струйники при печати в черновом режиме. К 100000 копиям были трижды поменяны ролики захвата/подачи. Качество печати аппарата можно оценить, как очень высокое, что неудивительно учитывая, что при двухкомпонентной печати заряд тонера на высоких скоростях производится намного лучше чем в однокомпонентных системах.
Про узел термозакрепления.
115R00085 Узел термозакрепления в сборе Ph3610/WC3615
Узел термозакрепления (она же печка) в Xerox 3610/3615 явно перекачивала с цветников. Для запекания используется тефлоновый вал, а вот вместо вала прижима используется пленка прижима. Я не знаю почему используется вместо вала прижима пленка, но точно могу сказать, что в печках Xerox это наиболее слабое место. В обслуживаемых аппаратах к 110000 копиям у одной печки пленка приказала долго жить. Во втором аппарате печка уже работает со сбоями, периодически вызывая ложные замятия. Ресурс печки официально составляет 200000 копий, что не соответствует реальности. Ценник на печку в 25000~30000 рублей приводит к тому, что после 100000 копий аппарат списывается и компании покупают аппараты другого бренда с более лояльной ценовой политикой.
Про чипы и тонер.
Традиционно картриджи Xerox чипованные, не избежал этой участи и Xerox 3610/3615. В картридже используется ставшим уже визуально привычным по аппаратам Xerox 3010/6010 четырехконтактный чип. Вот только ценник на этот чип составляет неожиданно много около 1400 рублей. С тонером для заправки картриджей все одновременно проще и сложнее. Тонер используется стандартный отрицательно заряженный, но вот как оказалось недорогой двухкомпонентный тонер от Xerox Phaser 5500 не подошел (бледная печать). После серии экспериментов оказалось, что засыпать нужно тонер от цветных принтеров Xerox типа 7500/7800 и т.д. Учитывая выше написанное ценник на заправку Xerox WorkCentre 3615DN для клиента получается от 4500 до 5500 рублей в зависимости от курса доллара и поставщика тонеров и чипа.
Подводя итоги.
Аппарат мне понравился своей скоростью и пожалуй безглючностью в плане софта, но вот при первой же относительно серьезной поломке аппарат придется списывать. На мой взгляд этот аппарат ни никак не тянет на замену Xerox Phaser 3635. За эти деньги лучше приобрести HP LaserJet Pro MFP M521dn или на крайний случай Kyocera ECOSYS M3040idn. Xerox WorkCentre 3615DN идеально подойдет для клиентского офиса где мало печатают, но нужно «пустить пыль в глаза».
Оцените качество заметки
Загрузка…
You are here: Home / error code / Xerox WorkCentre 3615 error and solving error codes
– Compatible Printer model: Xerox WorkCentre 3615
– Xerox WorkCentre 3615 Error Codes with quick guides:
- Code: 004-310
- Description: IOT Option Feeder I/F Failure Cause: The Option Feeder communication failure is detected.
- Troubleshooting Guides: 1 • Check the connections between the OPTIONAL TRAY PWB ASSEMBLY and the MCU PWB, as well as between the OPTIONAL TRAY PWB ASSEMBLY and the LVPS PWB. • Are the OPTIONAL FEEDER HARNESS ASSEMBLY and the FEEDER HARNESS ASSEMBLY DRAWER 1 connected securely? Go to Step 2. Securely connect the OPTIONAL FEEDER HARNESS ASSEMBLY and the FEEDER HARNESS ASSEMBLY DRAWER 1 2 • Replace the OPTIONAL FEEDER HARNESS ASSEMBLY. • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 1. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace (Optional Tray PWB Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 005-110, 005-112, 005-121
- Description: 005-110 PICKUP JAM 005-112 REVERSE JAM 005-121
- Troubleshooting Guides: 1 • Does the original document match the device specification? Go to Step 2. Use the correct original document 2 • Is the DADF ASSEMBLY properly closed against the Platen Glass? Go to Step 3. Close the DADF ASSEMBLY properly 3 Check the connection between the DADF ASSEMBLY and the ESS PWB. • Is the P/J453 connected securely? Go to Step 4. Connect P/J453 securely 4 • Open the DADF cover, and check the original document transport path. • Is there any foreign substances or bits of paper found on the original document transport path? Remove the foreign substances and bits of paper, etc. Go to Step 5. 5 • Is the DADF PICK UP MODULE installed properly? Go to Step 6. Reinstall the DADF PICK UP MODULE 6 • Is the DADF PICK UP MODULE deformed or worn out? Replace (Pick-up Module Kit) Go to Step 7. 7 • Replace (DADF). • Does an error occur? Replace (ESS PWB). Troubleshooting complete.
- Code: 005-124, 005-900
- Description: 005-124 Virtual JAM 005-900 DADF STATIC JAM
- Troubleshooting Guides: 1 • Does the original document match the device specification? Go to Step 2. Use the correct original document 2 • Is the DADF ASSEMBLY properly closed against the Platen Glass? Go to Step 3. Close the DADF ASSEMBLY properly 3 Check the connection between the DADF ASSEMBLY and the ESS PWB. • Is the P/J453 connected securely? Go to Step 4. Connect P/J453 securely 4 • Open the DADF cover, and check the original document transport path. • Is there any foreign substances or bits of paper found on the original document transport path? Remove the foreign substances and bits of paper, etc. Go to Step 5. 5 • Is the DADF PICK UP MODULE installed properly? Go to Step 6. Reinstall the DADF PICK UP MODULE 6 • Is the DADF PICK UP MODULE deformed or worn out? Replace (Pick-up Module Kit) Go to Step 7. 7 • Replace (DADF). • Does an error occur? Replace (ESS PWB). Troubleshooting complete.
- Code: 005-301
- Description: DADF Cover Open
- Troubleshooting Guides: 1 • Is the DADF Cover closed properly? Go to Step 2. Close the DADF Cover properly 2 Check the connection between the DADF ASSEMBLY and the ESS PWB. • Is the P/J453 connected securely? Go to Step 3. Connect P/J453 securely 3 • Replace (DADF). • Does an error occur? Replace (ESS PWB). Troubleshooting complete.
- Code: 010-317, 010-397
- Description: 010-317 FUSING ASSEMBLY Detached 010-397 FUSING ASSEMBLY Failure 010-317: FUSING ASSEMBLY detached is detected. 010-397: The operation error of FUSING ASSEMBLY (Temperature anomaly error etc.) is detected.
- Troubleshooting Guides: 1 Check the installation of the FUSING ASSEMBLY. • Is the Drawer Connector between the FUSING ASSEMBLY and the Main unit free of broken/bent pins, foreign substances, burns, and etc., and is the unit installed properly? • Make sure that the FUSING ASSEMBLY has cooled down before performing the operation. Go to Step 2. Reinstall the FUSING ASSEMBLY 2 Check the connection between the FUSING ASSEMBLY and the MCU PWB, FUSING ASSEMBLY and the LVPS, as well as between the LVPS PWB – MCU PWB. • Are the FUSER HARNESS ASSEMBLY and the LVPS HARNESS ASSEMBLY connected securely? Go to Step 3. Securely connect the Fuser HARNESS ASSEMBLY and the LVPS HARNESS ASSEMBLY 3 • Replace the FUSER HARNESS ASSEMBLY. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the LVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace (Fusing Assembly). Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (LVPS.) • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 016-338, 016-920, 016-921, 016-922
- Description: 016-338 Wireless Option Error 016-920/016-921/016-922 Wireless Setting Error Cause: 016-338:Wireless Driver starting error. 016-920:Timeout Error. 016-921:Download Error. 016-922:Session Overlap Error.
- Troubleshooting Guides: 016-338: Turn the power Off and On to check that the error recurs. Then proceed to the FIP. 016-920: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. • A time-out error occurred. Contact the system administrator. • The WPS procedure between the wireless LAN access point (Registrar) timed out. Try connecting again. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then proceed to the FIP. 016-921: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. • An error occurred while connecting. Contact the system administrator. • An error occurred while connecting to the wireless LAN access point (Registrar) in WPS mode. Try connecting again. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then proceed to the FIP. 016-922: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. • Two or more wireless LAN access points (Registrars) have been found to operate in the WPS-PBC mode. • Set only one wireless access point (Registrar) to operate in the WPS-PBC mode, and execute the process again according to the procedure. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then proceed to the FIP.
1 • Check the installation of the WIRELESS ADAPTER • Is the Connector between the WIRELESS ADAPTER and the ESS PWB free of broken/bent pins, foreign substances, burns, and etc., and is the unit installed properly? Go to Step 2. Reinstall the WIRELESS ADAPTER 2 • Replace the WIRELESS ADAPTER. • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 016-359
- Description: MRAM Fail Cause: MRAM Device Error
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 016-369
- Description: UI Panel – ESS Communication Fail Cause: Communication Fail with a UI Panel and ESS F/W.
- Troubleshooting Guides: 1 Check the connection between the CONTROL PANEL and the ESS PWB. • Is the UI HARNESS ASSEMBLY connected securely? Go to Step 2. Securely connect the UI HARNESS ASSEMBLY 2 • Replace the UI HARNESS ASSEMBLY. • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace the CONTROL PANEL. (Control Panel (3610) / Control Panel (3615)) • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 016-404
- Description: Certificate DB Error Cause: Certificate DB access error.
- Troubleshooting Guides: The Certificate DB is invalid. Initialize the Certificate DB and security setting and then restart the printer.
- Code: 016-405
- Description: Certificate DB Error Cause: Invalid security setting error.
- Troubleshooting Guides: Initialize the Certificate DB and security setting and then restart the printer. Contact the administrator for security resetting.
- Code: 016-500
- Description: Download Delete Error Cause: Flash delete error in download.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 016-501
- Description: Download Write Error Cause: Flash write error in download.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
Solve Xerox WorkCentre 3615 Error codes
- Code: 016-502
- Description: Download Verify Error Cause: Flash verify error in download.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 016-503
- Description: SMTP Server Address Resolution Fail for Maillib Cause: SMTP server name resolution for email send failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On the CWIS, check SMTP server is set correctly. In addition, check if DNS server is set correctly. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-504
- Description: POP Server Address Resolution Fail for Maillib Cause: POP3 server name resolution for email send failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On the CWIS, check POP3 server is set correctly. In addition, check if DNS server is set correctly. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-505
- Description: POP Authentication Fail for Maillib Cause: Cannot login to POP3 server to send email.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On CWIS, check if user name and password used for POP3 server are set correctly. In addition, check if DNS server is set correctly. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-506
- Description: Required user entry item is empty Cause: Some item is not set.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On CWIS, check if SMTP server or POP3 server is set. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-507
- Description: SMTP Authentication Fail for Maillib Cause: Cannot login to SMTP server to send email.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On CWIS, check if user name and password used for SMTP server are set correctly. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-520
- Description: Ipsec Certificate Error Cause: Self device certificate error.
- Troubleshooting Guides: 1. Certificate of self device is invalid. Contact administrator. • Reset the certificate from other connectable client with EWS. 2. If no device can be connected, disconnect cable, turn off IPsec, and then reset certificate with EWS.
- Code: 016-521
- Description: Ipsec Certificate Error Cause: Remote device certification verification error.
- Troubleshooting Guides: 1. Contact administrator. Certificate of destination client is invalid. 2. Confirm certificate of destination client and reset.
- Code: 016-522
- Description: LDAP Certificate Error Cause: No client certificate exists.
- Troubleshooting Guides: 1. Contact administrator. The SSL client certificate is requested by LDAP server. Set the SSL client certificate to the device. 2. Set the LDAP correctly.
- Code: 016-523
- Description: LDAP Certificate Error Cause: Server certificate verification error.
- Troubleshooting Guides: 1. The SSL certificate of LDAP server is not trusted by the device. Register the root certificate of the LDAP server’s SSL certificate with the device. 2. Set the LDAP correctly.
- Code: 016-524
- Description: LDAP Certificate Error Cause: No server certificate exists.
- Troubleshooting Guides: 1. Change the SSL certificate of the LDAP server to the valid one. 2. Set the LDAP correctly.
- Code: 016-527
- Description: LDAP Certificate Error Cause: SSL authentication internal error.
- Troubleshooting Guides: 1. Contact administrator. The error has occurred inside the program. 2. Set the LDAP correctly.
- Code: 016-530
- Description: LDAP Address Book- Access Error Cause: LDAP Address Book Other Access Errors.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Check the LDAP setting. 3. Update to the latest F/W. 4. If the error persists replace (ESS PWB).
- Code: 016-541
- Description: Wireless Certificate Error Cause: No certificate exits.
- Troubleshooting Guides: Initialize Wireless setting.
- Code: 016-542
- Description: Wireless Certificate Error Cause: Server certificate error.
- Troubleshooting Guides: Check server certificate.
- Code: 016-543
- Description: Wireless Certificate Error Cause: Certificate corruption error.
- Troubleshooting Guides: Initialize Wireless setting.
- Code: 016-570
- Description: Job Ticket Out Of Memory Cause: XPIF parser detects insufficient memory in the processing of XCPT (XPIF) interpretation.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists, an upgrade of the memory as required.
- Code: 016-571
- Description: Job ticket wrong Cause: Print instruction contents that the device cannot execute are detected.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time.
- Code: 016-572
- Description: Job ticket media error Cause: The paper attribute specified by XCPT (XPIF) cannot solve paper selection.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time.
- Code: 016-573
- Description: Job ticket parse error Cause: XPIF parser detects error other than those listed above.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time.
- Code: 016-602
- Description: System NVM Initialize Cause: At Power ON start-up, execute NVM clear.
- Troubleshooting Guides: The machine will recover after message is displayed for 3 seconds. No action is required.
- Code: 016-612
- Description: Invalid MAC Address Cause: MAC address is invalid.
- Troubleshooting Guides: 1. Rewrite Mac address. 2. Update to the latest F/W. 3. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-718
- Description: Memory Over flow Cause: The current printing job process cannot be continued because the memory capacity is exceeded.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Deleting the data by executing Clear Storage. 2. Execute ‘Clear Storage’ under ‘Maintenance’ in the Control Panel. 3. Ensure that the error is replicated after the printer is powered Off and then On, and then upgrade the memory as required.
- Code: 016-720
- Description: PDL Error Cause: The print data cannot be processed by PDL.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 2. Take corrective actions at the host side.
- Code: 016-734
- Description: Download Signature Error Cause: Download file signature data is invalid.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-737
- Description: Download Format Error Cause: Download file format is invalid.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-741
- Description: Download Protect Error Cause: Performed FW download although FW update is prohibited by panel settings.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-742
- Description: Download ID Error Cause: Download file ID is invalid.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-743
- Description: Download Range Error Cause: At download, write-in destination address is invalid. Range check error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-744
- Description: Download Check Sum Error Cause: Download file checksum is invalid.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-745
- Description: Download header Error Cause: Download file header is invalid.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-746
- Description: Prohibit Error Cause: Download Prohibit Error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Re-download the correct file. 3. Check the cable between the Printer and PC (or Printer and Hub). • For local printer: USB cable. • For network printer: Ethernet cable. 4. Take corrective actions at the host side.
- Code: 016-750
- Description: Job Ticket Error Cause: PDF print job ticket description error.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists, check the PDF data and then take corrective actions at the host side.
- Code: 016-753
- Description: Wrong Password Cause: PDF password error.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists, enter the correct PDF document password again, and then take corrective actions at the host side.
- Code: 016-755
- Description: PDF Print Disabled Cause: PDF print is not allowed.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists, enter the correct PDF document password again, and then take corrective actions at the host side.
- Code: 016-757
- Description: Auditron – Invalid User Cause: Account is not registered.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists, set the correct user’s account (user name and password), and then take corrective actions at the host side.
- Code: 016-758
- Description: Auditron – Disabled Function Cause: Detect invalid account.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Set the new function that is allowed for that account and try again. 2. Request the Account Administrator to add the rights, and then update to the latest F/W. 3. Take corrective actions at the host side.
- Code: 016-759
- Description: Auditron – Reached Limit Cause: Reached the limit of the number of registered users.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Set the correct value of ‘User Registration’exceed the limitation. 2. Update to the latest F/W. 3. Take corrective actions at the host side.
- Code: 016-764
- Description: SMTP Server Connection Error Cause: Error occurs when connecting to SMTP server.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Contact the SMTP Server Administrator. • Check the network connection using the ping command. • Check the network setting.(E-Mail Server Settings / DNS settings) 2. Take corrective actions at the host side.
- Code: 016-765
- Description: SMTP Server HD Full Cause: Capacity of SMTP server is not enough.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Contact the SMTP Server Administrator. 2. Retrieve E-mails in the SMTP Server HD and check the server capacity. 3. Take corrective actions at the host side.
- Code: 016-766
- Description: SMTP Server File System Error Cause: Error in SMTP server.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Contact the SMTP Server Administrator. 2. Check the SMTP Server Error. 3. Take corrective actions at the host side.
- Code: 016-767
- Description: Invalid Recipient Email Address Cause: Recipient email address is incorrect.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check the email address and try scanning again. 2. Take corrective actions at the host side.
- Code: 016-768
- Description: Invalid Sender Address (Login Error) Cause: Sender email address is incorrect.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check the email address and try scanning again. 2. Take corrective actions at the host side.
- Code: 016-786
- Description: Data Send/Receive Timeout Error Cause: Timeout error occurs in scan data send/receive.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check if the network cable is disconnected or connected properly. When there is no problem with network cable, contact Server Administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 016-790
- Description: F2N Module Starting-up Cause: F2N module task is starting up, or IP address is not determined.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check if the network cable is disconnected or connected properly. When there is no problem with network cable, contact Server Administrator. 2. Take corrective actions at the host side.
- Code: 016-791
- Description: USB Memory Removal Error (During Read) Cause: USB memory is removed while memory reading job is being executed.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check the USB Memory. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then change the USB. 3. Take corrective actions at the host side.
- Code: 016-799
- Description: Job Environment Violation Cause: Print condition conflicts with other condition.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Ensure that the printer configuration on the printer driver conforms to the printer you are using. 2. Take corrective actions at the host side.
- Code: 016-923
- Description: Wireless Password Error Cause: Wireless Password is wrong.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Modify the setting WEP Key or WPA Pass phrase. 2. Change the password.
- Code: 016-924
- Description: Wireless Setting Error Cause: WEP AP Connected Error.
- Troubleshooting Guides: 1. Press set and try again. 2. Reinstall the WIRELESS ADAPTER. 3. If the problem cannot be solved, configure the wireless settings again.
- Code: 016-930
- Description: USB Host Error Cause: Warning when unsupported device is installed to USB host. • Detect installation of device of which class driver cannot be found. • Detect installation of device that class driver judges not to support. • Detect installation of Low-Speed device.
- Troubleshooting Guides: 1. Devices not available are connected to the USB port. • Remove the devices from the USB port. 2. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-931
- Description: USB Hub Error Cause: • Warning to installation of hub that cannot be used to USB host. • Detect installation of hubs in more than supported number of stacks.
- Troubleshooting Guides: 1. The number of hub stages exceeds the specified value. • Reduce the number of the hub stages. 2. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-982
- Description: Disk Full Cause: The current printing job process cannot be continued because the RAM disk is full.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. It is necessary to delete unnecessary data or System Settings increase the RAM Disk capacity in System Settings. 2. After increasing the RAM Disk capacity, turn the printer Off and then On. 3. Ensure that the error is replicated after the printer is powered Off and then On, and then divide the print job into several blocks, then execute printing on a block by block basis. • Upgrade memory as required. • Upgrade SD CARD as required.
- Code: 016-985
- Description: Mail Size Error Cause: Exceed the max mail size specified on the menu.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Degrade image quality. (Change scan resolution, etc.) 2. Change file format. 3. Divide the document into blocks and retry scanning block by block. 4. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 016-986
- Description: File Size Error Cause: As a result of conversion to the specified format, exceed the max file size specified for each format.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Degrade image quality. (Change scan resolution, etc.) 2. Change file format. 3. Divide the document into blocks and retry scanning block by block. 4. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 024-340
- Description: Engine Controller Error Cause: Engine firmware error occurs.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (MCU PWB).
- Code: 024-360
- Description: Engine Code DownLoad Error Cause: Download failure of MCU firmware.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (MCU PWB).
- Code: 024-362
- Description: Print Engine Start Error Cause: ‘Start Image Making’ has not been issued within the time allowed.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (MCU PWB) • (ESS PWB)
- Code: 024-371
- Description: Engine Communication Error Cause: Communication fail between MCU and ESS.
- Troubleshooting Guides: 1 Check the connection between the MCU PWB and the ESS PWB. • Is the ESS HARNESS ASSEMBLY connected securely? Go to Step 2. Securely connect the ESS HARNESS ASSEMBLY 2 • Replace the ESS HARNESS ASSEMBLY. • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace (MCU PWB). • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 024-910
- Description: Tray 1 Paper Size Mismatch Cause: The size of paper in the Tray 1does not match the specified print size.
- Troubleshooting Guides: 1. Open/close Tray, or reseat paper on the manual feed tray. 2. Use the paper that meets the specifications. 3. Make sure that you are using the correct printer driver. 4. Check the Paper Size and Paper Type of the Tray Setting menu on the printer operator panel and the printer driver. 5. If the problem cannot be solved, replace the corresponding paper feed rolls. • TRAY 1 FEED ROLL / NUDGER ROLL (PL 2.3 Feed Assembly) • TRAY 1 RETARD ROLL (PL 7.3 Tray 1/Optional Tray 550-Sheet Feeder (3/4)) • RUBBER ROLL ASSEMBLY (PL 2.2 Transport Assembly) • REGI PINCHROLL ASSEMBLY (PL 2.2 Transport Assembly) • REGI PINCH ROLL (PL 2.2 Transport Assembly)
- Code: 024-911, 024-912, 024-913
- Description: 024-911 Tray 2 Paper Size Mismatch 024-912 Tray 3 Paper Size Mismatch 024-913 Tray 4 Paper Size Mismatch Cause: 024-911: The size of paper in the Tray 2 does not match the specified print size. 024-912: The size of paper in the Tray 3 does not match the specified print size. 024-913: The size of paper in the Tray 4 does not match the specified print size.
- Troubleshooting Guides: 1. Open/close Tray, or reseat paper on manual feed tray. 2. Use the paper that meets the specifications. 3. Make sure that you are using the correct printer driver. 4. Check the Paper Size and Paper Type of the Tray Setting menu on the printer operator panel and the printer driver. 5. If the problem cannot be solved, replace the corresponding paper feed rolls. • FEED ROLL / NUDGER ROLL (PL 7.2 Tray 1/Optional Tray 550-Sheet Feeder (2/4)) • RETARD ROLL (PL 7.3 Tray 1/Optional Tray 550-Sheet Feeder (3/4)) • TAKE AWAYROLL ASSEMBLY (PL 7.2 Tray 1/Optional Tray 550-Sheet Feeder (2/4)) • TAKE AWAYROLL PINCH (PL 7.4 Tray 1/Optional Tray 550-Sheet Feeder (4/4)) • RUBBER ROLL ASSEMBLY (PL 2.2 Transport Assembly) • REGI PINCHROLL ASSEMBLY (PL 2.2 Transport Assembly) • REGI PINCH ROLL (PL 2.2 Transport Assembly)
- Code: 024-920
- Description: IOT Standard Stacker Full Cause: Output Tray Full is Detected.
- Troubleshooting Guides: 1 • Check the shapes of the ACTUATOR FULL STACK • Do the ACTUATOR FULL STACK move smoothly? Do they have any damage? Replace the ACTUATOR FULL STACK. Go to Step 2. 2 • Execute the Diag Digital Input 071-122 to check the operation of the FULL STACK SENSOR. • Is the FULL STACK SENSOR operating normally? Replace (MCU PWB)
1 • Check the connection between the FULL STACK SENSOR and the MCU PWB. • Is the EXIT SENSOR HARNESS ASSEMBLY (P/J272 – P/J27) connected securely? Go to Step 2. Securely connect the EXIT SENSOR HARNESS ASSEMBLY 2 • Replace the EXIT SENSOR HARNESS ASSEMBLY. • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace (Full Stack Sensor). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 024-958
- Description: MSI Paper Size Mismatch Cause: The size of paper in the MSI does not match the specified print size.
- Troubleshooting Guides: 1. Open/close Tray, or reseat paper on manual feed tray. 2. Use the paper that meets the specifications. 3. Make sure that you are using the correct printer driver. 4. Check the Paper Size and Paper Type of the Tray Setting menu on the printer operator panel and the printer driver. 5. If the problem cannot be solved, replace the corresponding paper feed rolls. • MSI FEED ROLL / NUDGER ROLL (PL 2.6 MSI) • MSI RETARD ROLL (PL 2.7 Bypass Tray) • RUBBER ROLL ASSEMBLY (PL 2.2 Transport Assembly) • REGI PINCHROLL ASSEMBLY (PL 2.2 Transport Assembly) • REGI PINCH ROLL (PL 2.2 Transport Assembly)
- Code: 024-959 … 024-963
- Description: 024-959 Tray 1 No Suitable Paper 024-960 Tray 2 No Suitable Paper 024-961 Tray 3 No Suitable Paper 024-962 Tray 4 No Suitable Paper 024-963 MSI No Suitable Paper Cause: • Displayed when any of the following errors occur and tray setting needs to be changed after paper is loaded. • When paper source auto selection is selected, paper sizes of all existing trays do not match. (All Tray Size Mismatch) • When a tray is specified, no paper is loaded in the specified tray. (Specified Tray Emptied • When a tray is specified, paper size loaded in the specified tray does not match. (Specified Tray Size Mismatch • When Substitute Tray is Off and a paper type is specified, there is no tray loading the specified paper type. (Specified Tray Media Mismatch)
- Troubleshooting Guides: 1. Change tray setting, or cancel the job. 2. Use the paper that meets the specifications. 3. Check the Paper Size of the Tray Setting menu on the printer operator panel and the printer driver.
- Code: 026-720
- Description: USB Memory Full Cause: Writing to USB memory failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Delete unnecessary data. Change the USB Memory that satisfies the specification. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace the following parts in sequence. • (Front USB PWB) • (ESS PWB)
- Code: 026-721
- Description: USB Memory Write Error Cause: Writing to USB memory failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Change the USB Memory that satisfies the specification. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace the following parts in sequence. • (Front USB PWB) • (ESS PWB)
- Code: 027-446
- Description: IPv6 Duplicate Cause: At start-up, detect duplicate IPv6 address on network.
- Troubleshooting Guides: 1. Duplicate IPv6 addresses have been detected. Contact the system administrator. 2. Remove duplicates and then power off the printer and then on.Take corrective actions at the host side.
- Code: 027-452
- Description: IPv4 duplicate Cause: At start-up, detect duplicate IPv4 address on network.
- Troubleshooting Guides: 1. Duplicate IPv4 addresses have been detected. Contact the system administrator. 2. Remove duplicates and then power off the printer and then on. Take corrective actions at the host side.
- Code: 031-521
- Description: SMB Error Cause: In SMB scan, login-able workstation is restricted.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. About user settings, confirm the following with the system administrator. Restriction on loginable workstation. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-522
- Description: SMB user authentication fail or SMB Scanner login fail Cause: In SMB scan, login access is rejected. Request is not allowed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. About user settings, confirm the following with the system administrator. Restriction on loginable workstation. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-523
- Description: Problem with share name in SMB scan server Cause: Problem with share name in SMB scan server.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check SMB Server connection, or check share name you specified. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-524
- Description: SMB Scan User Over limit Cause: Exceed the upper limit of the number of SMB scan users.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check the number of users who use the server at the same time is not exceeding the upper limit. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-525
- Description: SMB Error Cause: SMB scan client has no access right (Win9x).
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the specified user can read and write file at the storage location. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-526
- Description: SMB Scan Host Name Resolution Fail Cause: SMB server name resolution failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check DNS connection, or check if name of forwarding destination server is registered with DNS. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-527
- Description: SMB Scan DNS Server Not Set Cause: DNS server is not set.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Set DNS address, or set forwarding destination server address as IP address. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-528
- Description: In SMB scan, server connection error Cause: Cannot find SMB server.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if this device can communicate by network with the forwarding destination SMB server. • Check connection of network cable, then check the TCP/IP setting. • Check communication with Port 137(UDP), 138(UDP), and 139(TCP). 2. Check setting of WINS server and if server name can be resolved correctly. 3. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 4. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-529
- Description: Problem with SMB scan login name or password Cause: Invalid password (Win9x).
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if password is correct. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-530
- Description: Problem with storage location of scanned image in SMB scan server Cause: Problem with storage location.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the storage location is correct. 2. Storage location you specified is DFS setting and check if it is linked to other server. 3. Specify the linked server, share name, and storage location. 4. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 5. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-531
- Description: Couldn’t get file/folder name of SMB scan server Cause: Couldn’t get file/folder name of server.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check access right of the folder you specified. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-532
- Description: Suffix of SMB scan file name/folder name is over limit Cause: Suffix of file name/folder name is over limit.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Change file name/forwarding destination folder, or move or delete file in forwarding destination folder. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-533
- Description: SMB Scan File Creation Fail Cause: Fail to create file.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the file name you specified can be created in storage location. 2. Check if the file name you specified is not used by other user. 3. Check if file or folder whose name is the same as the one you specified already exists. 4. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 5. Take corrective actions at the host side.
- Code: 031-534
- Description: SMB Scan Folder Creation Fail Cause: Fail to create folder.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the file name you specified can be created in storage location. 2. Check if file or folder whose name is the same as the one you specified already exists. 3. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 4. Take corrective actions at the host side.
- Code: 031-535
- Description: SMB Scan File Deletion Fail Cause: Fail to delete file.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if other user is not operating file in storage location you specified. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-536
- Description: SMB Scan Folder Deletion Fail Cause: Fail to delete folder.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if other user is not operating file in storage location you specified. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-537
- Description: No free space in storage location on SMB scan data server Cause: Storage location has no free space.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check storage location has free space. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-539
- Description: Invalid SMB server (Net BIOS) name is specified Cause: Invalid SMB server (Net BIOS) name is specified
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if server name is correct. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-540
- Description: SMB protocol error(4-007)Invalid scan domain name is specified Cause: Invalid domain name is specified. (User name is specified in domain user form)
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if domain name is correct. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-541
- Description: SMB protocol error (4-008) Invalid scan user name is specified Cause: Invalid scan user name is specified.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if login name (user name) is correct. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-542
- Description: SMB(TCP/IP) is not active Cause: SMB(TCP/IP) is not active.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Wait for a short period of time and try the same operation again. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-543
- Description: SMB protocol error(4-045)Scan login prohibited time Cause: Login prohibited time.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On user settings, check the Login permitted time with system administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-544
- Description: SMB protocol error(4-046) Password expired Cause: Password expired.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On user settings, check the password valid period with system administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-545
- Description: SMB protocol error(4-047) Password change is required Cause: Password change is required.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On user settings, check the necessity of password change with system administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-546
- Description: SMB protocol error(4-048)User is invalid Cause: User is invalid.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On user settings, check the user invalid setting with system administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-547
- Description: SMB protocol error(4-049)Lock-out Cause: User is locked out.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On user settings, check the user lock-out status with system administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 031-548
- Description: SMB protocol error (4-050) User is expired Cause: User is expired.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On user settings, check the user valid period with system administrator. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-549
- Description: SMB protocol error (4-051) User is restricted. Null password is prohibited Cause: User is restricted. Null password is prohibited.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. On server security settings, check the access permission of a password user. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-550
- Description: SMB Scan Append Command Fail Cause: Have no append access right to the file. Server does not support SMB append command.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check append access right to the file. Check server supports SMB append command. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-551
- Description: SMB Scan Rename Command Fail Cause: Have no rename access right to the file. Server does not support SMB rename command.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check rename access right to the file.Check server supports SMB rename command. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-552
- Description: SMB scan Cause: Cancel is selected for processing in the case of file name duplication, and job is cancelled because of file name duplication.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Set other than’Cancel’ for processing in the case of file name duplication, or change/delete the file name the same as the one specified in sending a destination folder. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 031-574
- Description: FTP Scan Host Name Resolution Fail Cause: DNS library call error.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check DNS connection, or check if name of forwarding destination server is registered with DNS. 2. Take corrective actions at the host side.
- Code: 031-575
- Description: FTP Scan DNS Server Not Set Cause: DNS library call error.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Set DNS address, or set forwarding destination server address as IP address. 2. Take corrective actions at the host side.
- Code: 031-576
- Description: Server Connection Error in FTP Scan Cause: Network connection failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if this device can communicate with forwarding destination FTP server. • Check if server’s IP address is correct. • Check connection of network cable. 2. Take corrective actions at the host side.
- Code: 031-578
- Description: FTP Scan Login Name or Password Error Cause: USER/PASS command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the login name (user name) and password are correct. 2. Take corrective actions at the host side.
- Code: 031-579
- Description: Problem with Location FTP-scanned Image is Saved in Cause: Fail to move data to Repository Path.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if storage location is correct. 2. Take corrective actions at the host side.
- Code: 031-580
- Description: Fail to get file name/folder name of FTP scan server Cause: NLST command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check server access right. 2. Take corrective actions at the host side.
- Code: 031-581
- Description: Suffix of FTP scan file name/folder name is over limit Cause: Same as left.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Change file name / forwarding destination folder, or move or delete file in forwarding destination folder. 2. Take corrective actions at the host side.
- Code: 031-582
- Description: FTP Scan File Creation Fail Cause: STOR command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the file name you specified can be created in storage location. 2. Check if there is free space in the storage location. 3. Take corrective actions at the host side.
- Code: 031-584
- Description: FTP Scan Folder Creation Fail Cause: MKD command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if the folder name you specified can be created in storage location. 2. Check if the folder whose name is the same as the one you specified already exists. 3. Take corrective actions at the host side.
- Code: 031-585
- Description: FTP Scan File Deletion Fail Cause: DEL command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check server access right. 2. Take corrective actions at the host side.
- Code: 031-587
- Description: FTP Scan Folder Deletion Fail Cause: RMD command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check server access right. 2. Take corrective actions at the host side.
- Code: 031-588
- Description: FTP Scan Server Data Write Fail Cause: Data writing to FTP scan server has failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check if there is free space in storage location. 2. Take corrective actions at the host side.
- Code: 031-590
- Description: FTP Error Cause: Cancel is selected for processing in the case of file name duplication, and job is cancelled because of file name duplication.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Set other than’Cancel’ for processing in the case of file name duplication, or change/delete file name the same as the one specified in sending destination folder. 2. Take corrective actions at the host side.
- Code: 031-594
- Description: FTP Scan TYPE Command Fail (Network Error) Cause: TYPE command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Do the same operation again. 2. If still not improved, contact the system administrator. 3. Check whether you have the access permission for appending files, or whether the server supports the append command of FTP. 4. Take corrective actions at the host side.
- Code: 031-595
- Description: FTP Scan PORT Command Fail (Network Error) Cause: PORT command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Do the same operation again. 2. If still not improved, contact the system administrator. Check whether you have the access permission for renaming files, or whether the server supports the rename command of FTP. 3. Take corrective actions at the host side.
- Code: 031-598
- Description: FTP Scan Append Command Fail Cause: APPE command failed.
- Troubleshooting Guides: The machine will recover after the OK or Close button is pressed or message is displayed for specified time. If the error persists: 1. Check append access right to the file.Check server supports FTP append command. 2. Take corrective actions at the host side.
- Code: 041-340
- Description: IOT NVRAM Error Cause: The operation error of NVM (read/write check error etc.) is detected.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (MCU PWB).
- Code: 041-347
- Description: IOT I/F Failure Cause: MCU Internal Error (I/F part).
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (MCU PWB) • (ESS PWB)
- Code: 042-313
- Description: LVPS Fan Motor Failure Cause: MCU detects an error upon receiving error signal from the LVPS Fan.
- Troubleshooting Guides: 1 • Execute the Diag Digital Output [042- 003] to check the rotation of the LVPS FAN. • Is it working properly? Replace (MCU PWB) Go to Step 2. 2 • Check the installation of the LVPS FAN. • Manually rotate the LVPS FAN. Is there any resistance? Reinstall the LVPS FAN properly Go to Step 3. 3 • Check the connection between the LVPS FAN and LVPS, as well as between the LVPS PWB and MCU PWB. • Are the LVPS FAN and the LVPS HARNESS ASSEMBLY connected securely? Go to Step 4. Securely connect the LVPS FAN and the LVPS HARNESS ASSEMBLY 4 • Replace the LVPS FAN. PL Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace the LVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (LVPS). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 042-330
- Description: Rear Fan Failure Cause: MCU detects an error upon receiving error signal from the Rear Fan.
- Troubleshooting Guides: 1 • Execute the Diag Digital Output [042-001] to check the rotation of the Rear Fan. • Is it working properly? Replace (MCU PWB) Go to Step 2. 2 • Check the installation of the Rear Fan. • Manually rotate the Rear Fan. Is there any resistance? Reinstall the Rear Fan properly Go to Step 3. 3 • Check the connection between the Rear Fan and the LVPS, as well as between the LVPS PWB and the MCU PWB. • Are the REAR FAN HARNESS ASSEMBLY and the LVPS HARNESS ASSEMBLY connected securely? Go to Step 4. Securely connect the REAR FAN HARNESS ASSEMBLY and the LVPS HARNESS ASSEMBLY 4 • Replace the Rear Fan. PL Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace the REAR FAN HARNESS ASSEMBLY. • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace the LVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 7. Troubleshooting complete. 7 • Replace (LVPS). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 042-700, 092-661
- Description: 042-700 IOT Over Heat Stop 092-661 IOT Environment Sensor Error Cause: 042-700: The Temp. Sensor sensed high temperature. 092-661: The Temp. Sensor or the Humidity Sensor error was detected.
- Troubleshooting Guides: 042-700: • Printing has been suspended because inside of the printer is extraordinarily hot. • Start the operation after the Printer has cooled down. • Turn the power Off and On to check that the error recurs. Then proceed to the FIP. 092-661: Turn the power Off and On to check that the error recurs. Then proceed to the FIP.
1 Is there a heat source near the device? Remove the heat source Go to Step 2. 2 Are there any foreign substances in the Temp. Sensor /Humidity Sensor HVPS Detector? Remove the foreign substances Go to Step 3. 3 • Check the connection between the HVPS and the MCU PWB. • Is the HVPS HARNESS ASSEMBLY connected securely? Go to Step 4. Securely connect the HVPS HARNESS ASSEMBLY 4 • Replace the HVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace (HVPS (3610)) (HVPS (3615)). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 050-130
- Description: IOT Remain Zone Fusing Jam 051-130 is displayed in the UI. Either of the following error codes is registered in the Error Log. • 077-104 Regi Off Jam • 077-106 Exit On Jam • 077-108 Exit Off Early Jam • 077-109 Exit Off Jam Cause: When Dynamic Jam (cause) was detected: • 077-104 Regi Off Jam • 077-106 Exit On Jam • 077-108 Exit Off Early Jam • 077-109 Exit Off Jam When Static Jam (collateral) was detected: • Exit Sensor On
- Troubleshooting Guides: Paper jam has occurred. Remove the jammed paper. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the appropriate FIP. • For 077-104 Regi Off Jam • For 077-106 Exit On Jam, 077-108 Exit Off Early Jam, and 077-109 Exit Off Jam, go to FIP 1. 284
- Code: 050-131, 077-107
- Description: 050-131 IOT Remain Zone Duplex Jam 077-107 Duplex Regi On Jam 050-131 is displayed in the UI. 077-107 is registered in the Error Log. Cause: 050-131: When Dynamic Jam (cause) was detected: – 077-107 Duplex Regi On Jam 077-107: After the Invert Clutch turned ON, the Regi. Sensor did not turn ON within the specified time.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-102] to check the operation of the Regi. Sensor HVPS. • Is the Regi. Sensor HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071- 008] to check the operation of the CLUTCH ASSEMBLY INVERT. • Is the CLUTCH ASSEMBLY INVERT operating normally? Step 6 Go to FIP 2.09 6 • Execute the Diag Digital Output [071- 001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
- Code: 050-132
- Description: IOT Remain Zone Regi + MSI + T1 + T2 Jam 050-132 is displayed in the UI. 077-106 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 077-106 Exit On Jam When Static Jam (collateral) was detected: • Regi Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 284.
- Code: 050-134
- Description: IOT Zone MSI + T1 Jam 051-134 is displayed in the UI. Either of the following error codes is registered in the Error Log. • 071-100 IOT Tray1 Misfeed Jam • 075-100 MSI Misfeed Jam Cause: When Dynamic Jam (cause) was detected: • 071-100 IOT Tray1 Misfeed Jam • 075-100 MSI Misfeed Jam
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP. • 071-100 IOT Tray1 Misfeed Jam, go to FIP 1. 273. • 075-100 MSI Misfeed Jam, go to FIP 1. 281.
- Code: 050-135
- Description: IOT Zone T2 + T3 + T4 + TR2 + TR3 Jam 050-135 is displayed in the UI. 073-101 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 073-101 IOT Path3 SNS On Jam When Static Jam (collateral) was detected: • Tray2 Path Sensor On, Tray3 Path Sensor On, and Tray4 Path Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to FIP 1. 277.
- Code: 050-136
- Description: IOT Zone T3 + T4 + TR3 Jam 050-136 is displayed in the UI. 072-101 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-101 IOT Path2 SNS On Jam When Static Jam (collateral) was detected: • Tray3 Path Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to FIP 1. 277.
- Code: 050-137
- Description: IOT Zone T2 + T3 + TR2 + TR3 Jam 050-137 is displayed in the UI. 072-102 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-102 IOT Option Regi On Jam When Static Jam (collateral) was detected: • Tray2 Path Sensor On and Tray3 Path Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to FIP 1. 278.
- Code: 050-138
- Description: 050-138 IOT Zone T3 + TR2 + TR3 Jam 050-138 is displayed in the UI. 072-102 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-102 IOT Option Regi On Jam When Static Jam (collateral) was detected: • Tray3 Path Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 278.
- Code: 050-139
- Description: IOT Zone T2 + TR2 Jam 050-139 is displayed in the UI. 072-100 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 072-100 IOT Tray2 Misfeed Jam When Static Jam (collateral) was detected: • Tray2 Path Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 276.
- Code: 050-140
- Description: IOT Zone T3 + TR2 Jam 050-140 is displayed in the UI. 073-100 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 073-100 IOT Tray3 Misfeed Jam
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 276.
- Code: 050-141
- Description: IOT Zone T4 + TR3 Jam 050-141 is displayed in the UI. 074-100 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 074-100 IOT Tray4 Misfeed Jam When Static Jam (collateral) was detected: • Tray4 Path Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 276.
- Code: 050-142
- Description: IOT Remain Zone Regi + MSI + T1 Jam 050-142 is displayed in the UI. 077-106 is registered in the Error Log. Cause: When Dynamic Jam (cause) was detected: • 077-106 Exit On Jam When Static Jam (collateral) was detected: • Regi Sensor On
- Troubleshooting Guides: 1. Paper jam has occurred. Remove the jammed paper. 2. If there is no jammed paper, or the error still occurs after having removed the jammed paper, turn the power Off and On to check that the error recurs, then proceed to the FIP 1. 284.
- Code: 061-370
- Description: IOT ROS Failure Cause: The operation error of ROS (rotational error etc.) is detected.
- Troubleshooting Guides: 1 Check the connections between the ROS ASSEMBLY and the MCU PWB, as well as between the ROS ASSEMBLY and the ESS PWB. • Are the ROS-MCU HARNESS (P/J501- P/J19), ROS ASSEMBLY (P/J18), and the VIDEO HARNESS (P/J502 – P/J322) connected securely? Go to Step 2. Securely connect the ROS-MCU HARNESS, ROS ASSEMBLY and the VIDEO HARNESS 2 • Replace (ROS Assembly). • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace (MCU PWB). • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 062-277 … 062-393
- Description: 062-277: IIT internal communication error. 062-311: IIT failure initialization error. 062-317: Interference buffer full was detected at the time of DADF scan. 062-318: A Scan setup did not meet the deadline into Page Gap. 062-319: A PLL lock was not carried out before 1stScan start, but the lock has separated during continuation. 062-320: Scanning error. 062-321: Unexecutable error. (carriage is at the locked position, etc.) 062-322: Parameter error. 062-360: Carriage home position error. 062-371: IIT failure Lamp error. 062-393: CCD ASIC communication error.
- Troubleshooting Guides: 062-277/062-311/062-317/062-318/062-319/062-321/062-322/062-360/062-371/062-393: • Turn the power Off and On to check that the error recurs. Then proceed to the FIP. 062-320: 1. Check the file data in the printer. Print or clear the stored files and data at the printer memory. 2. Perform a black and white scan. 3. If the error occurs again, proceed to the FIP.
1 Check the connection between the IIT ASSEMBLY and the ESS PWB. • Are the P/J451 and the P/J452 connected securely? Go to Step 2. Connect that P/J451 and P/J452 are secure 2 • Replace (IIT Assembly). • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 062-316
- Description: DADF Motor Fail Cause: Detect DADF Motor Fail.
- Troubleshooting Guides: 1 Are there any foreign substances in the DADF Motor Drive Section? Remove the foreign substances. Go to Step 2. 2 Check the connection between the DADF ASSEMBLY and the ESS PWB. • Is the P/J453 connected securely? Go to Step 3. Connect P/J453 securely 3 • Replace (DADF). • Does an error occur? Replace (ESS PWB). Troubleshooting complete.
- Code: 062-790
- Description: Copy Limit Cause: Copy Limit.
- Troubleshooting Guides: The machine will recover after the Enter Key is pressed or message is displayed for 60 seconds. If the error persists: 1. Change your original. 2. Ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 071-100
- Description: IOT Tray1 Misfeed Jam 050-134 is displayed in the UI. Cause: After the Tray 1 Feed Clutch turned ON, the Regi. Sensor did not turn ON within the specified time.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-102] to check the operation of the Regi. Sensor HVPS. • Is the Regi. Sensor HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071-005] to check the operation of the CST FEED CLUTCH. • Is the CST FEED CLUTCH operating properly? Go to Step 6. Go to FIP 2.11 6 • Execute the Diag Digital Output [071-001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
- Code: 071-920
- Description: Waiting to Print Side 2 Load Printed Pages into the NNN Cause: Waiting for side 2 to be set for manual duplex print (Tray).
- Troubleshooting Guides: Set the Paper correctly. Press OK button within the specified time.
- Code: 071-921
- Description: Manual Duplex Print Cause: Waiting for Set key to be pressed after setting side 2 for manual duplex print (Tray).
- Troubleshooting Guides: Set the Paper correctly. Press OK button within the specified time.
- Code: 072-100, 073-100, 074-100
- Description: 072-100 IOT Tray2 Misfeed Jam 073-100 IOT Tray3 Misfeed Jam 074-100 IOT Tray4 Misfeed Jam Cause: 072-100: 050-139 is displayed in the UI. After the Tray 2 Feed Clutch turned ON, the Tray 2 Path Sensor did not turn ON within the specified time. 073-100: 050-140 is displayed in the UI. After the Tray 3 Feed Clutch turned ON, the Tray 3 Path Sensor did not turn ON within the specified time. 074-100: 050-141 is displayed in the UI. After the Tray 4 Feed Clutch turned ON, the Tray 4 Path Sensor did not turn ON within the specified time.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input Tray 2: 071- 119 / Tray 3:071-120 / Tray 4:071-121 to check the operation of the Path Sensor. • Is the Path Sensor operating normally? Go to Step 5. Go to FIP 2.07 5 • Execute the Diag Digital Output Tray 2: 071-018 / Tray 3:071-019 / Tray 4:071-020 to check the operation of the OPTIONAL FEEDER CLUTCH ASSEMBLY. • Is the OPTIONAL FEEDER CLUTCH ASSEMBLY operating normally? Go to Step 6. Go to FIP 2.12 6 • Execute the Diag Digital Output Tray 2: 071-009 / Tray 3:071-012 / Tray 4:071-015 to check the rotation of the MOTORASSEMBLY OPTION. • Is it working properly? Go to Step 7. Go to FIP 2.17 7 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 072-101, 073-101
- Description: 072-101 IOT Path 2 SNS On Jam 073-101 IOT Path 3 SNS On Jam Cause: 072-101: 050-136 is displayed in the UI. The Tray 2 Path Sensor did not turn ON within the specified time after the Tray 3 Path Sensor turned ON. 073-101: 050-135 is displayed in the UI. The Tray 3 Path Sensor did not turn ON within the specified time after the Tray 4 Path Sensor turned ON.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input Tray 2: 071- 119 / Tray 3:071-120 / Tray 4:071-121 to check the operation of the Path Sensor. • Is the Path Sensor operating normally? Go to Step 5. Go to FIP 2.07 5 • Execute the Diag Digital Output Tray 2: 071-018 / Tray 3:071-019 / Tray 4:071-020 to check the operation of the OPTIONAL FEEDER CLUTCH ASSEMBLY. • Is the OPTIONAL FEEDER CLUTCH ASSEMBLY operating normally? Go to Step 6. Go to FIP 2.13 6 • Execute the Diag Digital Output Tray 2: 071-009 / Tray 3:071-012 / Tray 4:071-015 to check the rotation of the OPTIONAL TRAY MOTOR-ASSEMBLY. • Is it working properly? Go to Step 7. Go to FIP 2.17 7 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 072-102
- Description: IOT Option Regi On Jam Either of the following error codes is displayed in the UI. • 050-137 • 050-138 Cause: After the Tray 2 Path Sensor turned ON, the Regi. Sensor did not turn ON within the specified time.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input 071-102 to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Input [071-119] to check the operation of the Tray 2 Path Sensor. • Is the Tray 2 Path Sensor operating normally? Go to Step 6. Go to FIP 2.07 6 • Execute the Diag Digital Output 071-021 to check the operation of the Tray 2 TAKE AWAY CLUTCH. • Is the Tray 2 TAKE AWAY CLUTCH operating normally? Go to Step 7. Go to FIP 2.13 7 • Check the operation of the OPTIONAL TRAY MOTOR-ASSEMBLY • Execute the Diag Digital Output Tray 2: [071-009] to check the rotation of the OPTIONAL TRAY MOTOR-ASSEMBLY. • Is it working properly? Go to Step 8. Go to FIP 2.17 8 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 072-211
- Description: Feeder 2 Error Cause: IOT Option Feeder2 Failure.
- Troubleshooting Guides: 1 Check the operation of the OPTIONAL TRAY MOTOR ASSEMBLY (when the Optional Sheet Feeder is installed) • Execute the Diag Digital Output [071-009] to check the rotation of the OPTIONAL TRAY MOTOR ASSEMBLY. • Is it working properly? Go to Step 2. Go to FIP 2.17 2 Check the connections between the OPTIONAL TRAY PWB ASSEMBLY and the MCU PWB, as well as between the OPTIONAL TRAY PWB ASSEMBLY and the LVPS PWB. • Are the OPTIONAL TRAY HARNESS ASSEMBLY (P/J213P/J243, P/J24P/J243) and the HARNESS ASSEMBLY FEEDER DRAWER 1 (P/J243P/J419) connected securely? Go to Step 3. Securely connect the OPTIONAL FEEDER HARNESS ASSEMBLY FEEDER and the DRAWER 1 HARNESS ASSEMBLY 3 • Replace the OPTIONAL FEEDER HARNESS ASSEMBLY. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the DRAWER 1 FEEDER HARNESS ASSEMBLY . • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace (Optional Tray PWB Assembly) • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 073-211, 074-211
- Description: 073-211 Feeder 3 Error 074-211 Feeder 4 Error Cause: 073-211: IOT Option Feeder3 Failure. 074-211: IOT Option Feeder4 Failure.
- Troubleshooting Guides: 1 Check the operation of the OPTIONAL TRAY MOTOR ASSEMBLY • Execute the Diag Digital Output Tray 3:071- 012 / Tray 4:071-015 to check the rotation of the OPTIONAL TRAY MOTOR ASSEMBLY. • Is it working properly? Go to Step 2. Go to FIP 2.17 2 Check the connection between the OPTIONAL TRAY PWB ASSEMBLY (Upper) and the OPTIONAL TRAY PWB ASSEMBLY (Lower). • Are the FEEDER HARNESS ASSEMBLY DRAWER 2 (P/J423P/J4231) and the FEEDER HARNESS ASSEMBLY DRAWER 1 (P/J4231P/J419) connected securely? Go to Step 3. Securely connect the FEEDER HARNESS ASSEMBLY DRAWER 2 and the FEEDER HARNESS ASSEMBLY DRAWER 1 3 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 2. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 1. • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace(Optional Tray PWB Assembly) • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 075-100
- Description: MSI Misfeed Jam 050-134 is displayed in the UI. Cause: After the MSI Feed Solenoid turned ON, the Regi. Sensor did not turn ON within the specified time.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-102] to check the operation of the REGI-SENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071-004] to check the operation of the SOLENOID FEED MSI. • Is the SOLENOID FEED MSI operating normally? Go to Step 6. Go to FIP 2.14 6 • Execute the Diag Digital Output [071-001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
- Code: 077-101
- Description: VSYNC ON Jam Cause: Detect VSYNC ON Jam.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (MCU PWB).
- Code: 077-104
- Description: Regi. Off Jam 050-130 is displayed in the UI. Cause: The Regi Sensor does not turn OFF within the specified time after the Regi Clutch turned On.
- Troubleshooting Guides: 1 Is there any foreign substances or bits of paper found on the paper transport path? Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071- 102] to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 5. Go to FIP 2.03 5 • Execute the Diag Digital Output [071- 006] to check the operation of the REGI. CLUTCH. • Is the REGI. CLUTCH operating normally? Go to Step 6. Go to FIP 2.10 6 • Execute the Diag Digital Output [071- 001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
- Code: 077-106, 077-108, 077-109
- Description: 077-106 Exit On Jam 077-108 Exit Off early Jam 077-109 Exit Off Jam Cause: 077-106: Either of the following error codes is displayed in the UI. 050-130 – 050-132 – 050-142 The Exit Sensor does not turn ON within the specified time after the Regi Clutch turned On. 077-108: 050-130 is displayed in the UI. After the Exit Sensor turned ON, the Exit Sensor turned OFF before the specified time. 077-109: 050-130 is displayed in the UI. After the Regi. Sensor turned OFF, the Exit Sensor did not turn OFF within the specified time.
- Troubleshooting Guides: 1 • Is there any foreign substances or bits of paper found on the paper transport path? Note: Make sure that the FUSING ASSEMBLY has cooled down before performing the operation. Remove the foreign substances and bits of paper, etc. Go to Step 2. 2 Are the paper feed rolls installed properly? Go to Step 3. Reinstall the corresponding paper feed rolls 3 Are the paper feed rolls deformed or worn out? Replace the corresponding paper feed rolls Go to Step 4. 4 • Execute the Diag Digital Input [071-103] to check the operation of the EXIT SENSOR. • Is the EXIT SENSOR operating normally? Go to Step 5. Go to FIP 2.01 5 • Execute the Diag Digital Input [071-102] to check the operation of the REGISENSOR HVPS. • Is the REGI-SENSOR HVPS operating normally? Go to Step 6. Go to FIP 2.03 6 • Execute the Diag Digital Output [071-007] to check the operation of the EXIT CLUTCH ASSEMBLY. • Is the EXIT CLUTCH ASSEMBLY operating normally? Go to Step 7. Go to FIP 2.08 7 • Execute the Diag Digital Output [071-006] to check the operation of the REGI. CLUTCH. • Is the REGI. CLUTCH operating normally? Go to Step 8. Go to FIP 2.10 8 • Execute the Diag Digital Output [071-001] to check the rotation of the MAIN DRIVE ASSEMBLY. • Is it working properly? Replace (MCU PWB) Go to FIP 2.15
- Code: 077-215, 077-217
- Description: 077-215 IOT Duplex Error 077-217 Duplex Miss Configuration Cause: Duplex Unit Configuration error is detected.
- Troubleshooting Guides: Turn the power Off and On to check that the error recurs, then replace the Duplex Unit.
- Code: 077-300
- Description: IOT Cover Front Open Cause: Beep sounds after Front Cover remains open for 3 minutes.
- Troubleshooting Guides: 1 • Is the protruding portion of the FRONT COVER ASSEMBLY damaged? Replace (Front Cover Assembly (3610 / 3615)) Go to Step 2. 2 • Execute the Diag Digital Output [041- 300] to check the operation of the Front Interlock Switch. • Is it working properly? Replace (MCU PWB) Go to Step 3. 3 • Check the connection between the LVPS PWB and the MCU PWB. Is the LVPS HARNESS ASSEMBLY (P/J220P/J22) connected securely? Go to Step 4. Securely connect the LVPS HARNESS ASSEMBLY 4 • Replace the LVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace the Front Interlock Switch. • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 077-304
- Description: IOT Cover Rear Open Cause: The Rear Cover is open.
- Troubleshooting Guides: 1 • Is the protruding portion of the REAR COVER ASSEMBLY damaged? Replace (Rear Cover Assembly) Go to Step 2. 2 • Execute the Diag Digital Output 041-301 to check the operation of the Rear Interlock Switch. • Is it working properly? Replace (MCU PWB) Go to Step 3. 3 • Check the connection between the Rear Interlock Switch and the LVPS, as well as between the LVPS PWB and the MCU PWB. • Are the Rear Interlock Switch (P/J230) and the LVPS HARNESS ASSEMBLY (P/J220P/J22) connected securely? Go to Step 4. Securely connect the Rear Interlock Switch and the LVPS HARNESS ASSEMBLY 4 • Replace the (Rear Interlock Switch Assembly). Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Replace the LVPS HARNESS ASSEMBLY. • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (LVPS). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
– Get more error code list with quick guide to fix printer product, click here
- Code: 077-312
- Description: Tray Configure Error Cause: Tray configuration error was detected. (including all of the wrong configurations)
- Troubleshooting Guides: 1 • Does the Tray configuration suit the specification? Go to Step 2. Change the Tray configuration related to the specification 2 • Check the connections between the OPTIONAL TRAY PWB ASSEMBLY and the MCU PWB, as well as between the OPTIONAL TRAY PWB ASSEMBLY and the LVPS PWB. • Are the OPTIONAL FEEDER HARNESS ASSEMBLY (P/J213P/J243, P/J24P/J243) and the FEEDER HARNESS ASSEMBLY DRAWER 1 (P/J243P/J419) connected securely? Go to Step 3. Securely connect the OPTIONAL FEEDER HARNESS ASSEMBLY and the FEEDER HARNESS ASSEMBLY DRAWER 1 3 • Replace the OPTIONAL FEEDER HARNESS ASSEMBLY. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 1. • Does an error occur? Go to Step 5. Troubleshooting complete. 5 • Check the connection between the OPTIONAL TRAY PWB ASSEMBLY (Upper) and the OPTIONAL TRAY PWB ASSEMBLY (Lower). Are the FEEDER HARNESS ASSEMBLY DRAWER 2 (P/J423 – P/J4231) and the FEEDER HARNESS ASSEMBLY DRAWER 1 (P/J4231 – P/J419) connected securely? Go to Step 6. Securely connect the FEEDER HARNESS ASSEMBLY DRAWER 2 and the FEEDER HARNESS ASSEMBLY DRAWER 1 6 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 2. • Does an error occur? Go to Step 7. Troubleshooting complete. 7 • Replace the FEEDER HARNESS ASSEMBLY DRAWER 1. • Does an error occur? Go to Step 8. Troubleshooting complete. 8 • Replace (Optional Tray PWB Assembly) • Does an error occur? Go to Step 9. Troubleshooting complete. 9 • Replace (Feeder Assembly). • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 091-914, 091-915, 091-921, 091-963
- Description: 091-914 IOT Drum Communication Fail 091-915 Drum CRUM Data Broken Fail 091-921 IOT Drum Detached 091-963 IOT Drum CRUM ID Error Cause: 091-914: Communication failure with Drum CRUM was detected. 091-915: Malfunction of Drum CRUM was detected. 091-921: It was detected that the Drum CRUM is not at the specified position.(Loose CRUM) 091-963: The Drum CRUM ID error was detected.
- Troubleshooting Guides: 1 Is the DRUM CARTRIDGE installed properly, with no foreign substances at the contact point between the CRUM in the DRUM CARTRIDGE and the XEROGRAPHIC CONNECTOR ASSEMBLY? Go to Step 2. Reinstall the DRUM CARTRIDGE 2 Is the DRUM CARTRIDGE, which is installed in the device, a genuine product? Go to Step 3. Replace the DRUM CARTRIDGE with a genuine product 3 Is the connection terminal of the CRUM part in the DRUM CARTRIDGE damaged? Replace the DRUM CARTRIDGE Go to Step 4. 4 Is the connection terminal of the XEROGRAPHIC CONNECTOR ASSEMBLY damaged? Replace (Xerographic Connector Assembly) Go to Step 5. 5 • Check the connection between the XEROGRAPHIC CONNECTOR ASSEMBLY and the MCU PWB. • Is the XEROGRAPHIC CRUM HARNESS ASSEMBLY (P/J254 – P/J25) connected securely? Go to Step 6. Securely connect the XEROGRAPHIC CRUM HARNESS ASSEMBLY 6 • Replace the DRUM CARTRIDGE. • Does an error occur? Go to Step 7. Troubleshooting complete. 7 • Replace (Xerographic Connector Assembly) • Does an error occur? Go to Step 8. Troubleshooting complete. 8 • Replace the XEROGRAPHIC CRUM HARNESS ASSEMBLY. • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 091-953
- Description: Drum Tape Staying Cause: The remaining Tape of the Drum Cartridge was detected.
- Troubleshooting Guides: Remove the Drum Cartridge Tape.
- Code: 092-315
- Description: ATC Fail Cause: The ATC Sensor error was detected.
- Troubleshooting Guides: 1 Is the DRUM CARTRIDGE installed properly, with no foreign substances at the contact point between the ATC Sensor in the DRUM CARTRIDGE and the XEROGRAPHIC CONNECTOR ASSEMBLY? Go to Step 2. Reinstall the DRUM CARTRIDGE 2 Is the connection terminal of the ATC SENSOR part in the DRUM CARTRIDGE damaged? Replace the DRUM CARTRIDGE Go to Step 3. 3 Is the connection terminal of the XEROGRAPHIC CONNECTOR ASSEMBLY damaged? Replace (Xerographic Connector Assembly) Go to Step 4. 4 • Check the connection between the XEROGRAPHIC CONNECTOR ASSEMBLY and the MCU PWB. • Is the XEROGRAPHIC CRUM HARNESS ASSEMBLY(P/J254 – P/J25) connected securely? Go to Step 5. Securely connect the XEROGRAPHIC CRUM HARNESS ASSEMBLY 5 • Replace the DRUM CARTRIDGE. • Does an error occur? Go to Step 6. Troubleshooting complete. 6 • Replace (Xerographic Connector Assembly). • Does an error occur? Go to Step 7. Troubleshooting complete. 7 • Replace the XEROGRAPHIC CRUM HARNESS ASSEMBLY. • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 093-426
- Description: Toner Near Life Cause: It was detected that the Toner Cartridge needed to be replaced soon.
- Troubleshooting Guides: The Toner Cartridge is approaching the replacement time. Prepare a new Toner Cartridge.
- Code: 093-922
- Description: Toner Low Density Cause: Low concentration of the Toner was detected.
- Troubleshooting Guides: 1 • Remove the TONER CARTRIDGE, shake it a few times, and then reinstall it. • Does an error occur? Go to Step 2. Troubleshooting complete. 2 • Remove the DRUM CARTRIDGE. • Is the contact points of the DRUM CARTRIDGE clean, and correctly installed? Go to Step 3. Clean the contact points and reinstall the DRUM CARTRIDGE 3 • Replace the TONER CARTRIDGE. • Does an error occur? Go to Step 4. Troubleshooting complete. 4 • Replace the DRUM CARTRIDGE. • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 093-925, 093-926, 093-928, 093-973
- Description: 093-925 Toner CRUM Error 093-926 Toner CRUM ID Error 093-928 Toner Type Error 093-973 Toner Detached Cause: 093-925: The Toner CRUM error was detected. 093-926: The Toner CRUM ID error was detected. 093-928: The Toner Type Error was detected. 093-973: Toner Detached
- Troubleshooting Guides: 1 Is the DRUM CARTRIDGE installed properly, with no foreign substances at the contact point between the CRUM in the TONER CARTRIDGE and theTONER DISPENSE CRUM ASSEMBLY? Go to Step 2. Reinstall the TONER CARTRIDGE 2 Is the TONER CARTRIDGE, which is installed in the device, a genuine product? Go to Step 3. Replace the TONER CARTRIDGE with a genuine product 3 Is the connection terminal of the CRUM part in the TONER CARTRIDGE damaged? Replace the TONER CARTRIDGE Go to Step 4. 4 Is the connection terminal of the TONER DISPENSE CRUM ASSEMBLY damaged? Replace (Toner Dispense CRUM Assembly) Go to Step 5. 5 • Check the connection between the CONNECTOR ASSEMBLY, the CRUM TONER, and the MCU PWB. • Is the XEROGRAPHIC CRUM HARNESS ASSEMBLY(P/J253 – P/J25) connected securely? Go to Step 6. Securely connect the XEROGRAPHIC CRUM HARNESS ASSEMBLY 6 • Replace the TONER CARTRIDGE. • Does an error occur? Go to Step 7. Troubleshooting complete. 7 • Replace (MCU PWB) • Does an error occur? Go to Step 8. Troubleshooting complete. 8 • Replace the XEROGRAPHIC CRUM HARNESS ASSEMBLY • Does an error occur? Replace (MCU PWB) Troubleshooting complete.
- Code: 093-933
- Description: Toner Life Over Cause: It was detected that the Toner Cartridge needed to be replaced soon.
- Troubleshooting Guides: The Toner Cartridge is approaching the replacement time. Prepare a new Toner Cartridge.
- Code: 116-210
- Description: USB Host Error Cause: Fatal error of USB Host driver.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-312, 116-313
- Description: 116-312 Encryption Key Error 116-313 Encryption Setting Error Cause: 116-312: Encryption key mismatch. 116-313: Encryption setting mismatch.
- Troubleshooting Guides: 1 Is the Connector (P/J221) between the SD CARD and the ESS PWB free of broken/bent pins, foreign substances, burns, and etc., and is the unit installed properly? Go to Step 2. Reinstall the SD CARD 2 • Re-set up the security of the SD CARD. • Does an error occur? Go to Step 3. Troubleshooting complete. 3 • Replace the SD CARD. • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 116-314
- Description: MAC Address Error Cause: On Board Network MAC Address Checksum Error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs, then replace (ESS PWB).
- Code: 116-315
- Description: ESS On Board RAM W/R Check Fail Cause: Detected by On Board RAM W/R Check at the time of initialization.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-317
- Description: ESS ROM Check (Main) Fail Cause: Main Program ROM checksum error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-324
- Description: ESS Illegal Exception Cause: CPU illegal exception.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-326
- Description: ESS NVRAM2 W/R Check Fail Cause: Detected by master NVRAM W/R check.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs, then replace (ESS PWB).
- Code: 116-327
- Description: ESS Instruction Cache Error Cause: CPU instruction cache error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-328
- Description: ESS Data Cache Error Cause: Communication fail between 1 CPU network and ESS F/W.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-343
- Description: ASIC Fail Cause: ASIC-related Fatal Error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-350
- Description: On Board Network Communication Fail Cause: Communication fail between 1 CPU network and ESS F/W.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Perform the following in sequence • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Update to the latest F/W. 4. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 116-351, 116-352, 116-355
- Description: Network Error Cause: 116-351: On Board Network Ethernet BIST parity/RAM R/W Error. 116-352: On Board Network Internal Loop back Error. 116-355: On Board Network Fatal Error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Perform the following in sequence • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Update to the latest F/W. 4. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 116-353, 116-356
- Description: 116-353 ESS SD CARD Fail 116-356 SD CARD Overwrite Error Cause: 116-353: Detect SD CARD Error. 116-356: Error has occurred during SD CARD overwrite.
- Troubleshooting Guides: 1 Is the Connector (P/J221) between the SD CARD and the ESS PWB free of broken/bent pins, foreign substances, burns, and etc., and is the unit installed properly? Go to Step 2. Reinstall the SD CARD 2 • Replace the SD CARD. • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 116-361
- Description: PCI Bus #0 Error Detected Cause: PCI Bus #0 Uncorrectable Error Detected. (Connected with Remora EX(x4 port))
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-362
- Description: PCI Bus #0 Host Bridge Controller Error Cause: PCI Bus #0 Host Bridge Controller Error. (Connected with Remora EX port)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-363
- Description: PCI Bus #1 Host Bridge Controller Error Cause: PCI Bus #1 Host Bridge Controller Error. (Connected with Remora EX port.)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-364
- Description: Timer Fail Cause: Timer error is detected.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, set the RTC correctly.
- Code: 116-366
- Description: PCI Bus #1 Error Detected> Cause: PCI Bus #1 Uncorrectable Error Detected. (Connected with RemoraEX(x1 port))
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-368
- Description: PCI Error Messages received from Bus #0 – Device #1 Cause: Remora EX PCI x1 port Error. (Device ID 0x65 (x1))
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-369
- Description: PCI Error Messages received from Bus #0 – Device #0 Cause: Remove EX PCI x4 port Error. (Device ID 0x64 (x4))
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-390
- Description: ESS NVRAM1 SIZE And ID Check Fail Cause: Detected by consistency check between NVRAM size requested by the system and actual size and consistency check of ID recorded at the first power-on.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 116-396
- Description: Fatal Error Related to Maillib Other Errors (of File 2 Net Library) Cause: S/W bug.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Perform the following in sequence • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Update to the latest F/W. 4. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 116-719
- Description: XPIF Parameter Cancelled Cause: Due to conflict among multiple print instructions, print instructions are ignored.
- Troubleshooting Guides: Make sure that you are using the correct printer driver.
- Code: 116-721
- Description: Collate Full Cause: Unable to collate due to insufficient memory.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Split the document into blocks to decrease the number of pages to be collated. 2. Upgrade SD CARD as required. 3. Take corrective actions at the host side.
- Code: 116-722
- Description: WSD (Web Services on Device) Scan destination error Cause: The scan job cannot be executed on the device-driven Web Services on Device Scan, because the destination PC has been stopped.
- Troubleshooting Guides: The machine will recover after the OK button is pressed or message is displayed for specified time. If the error persists: 1. Check the destination PC. 2. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 116-987
- Description: Fatal Error Related to Format Library Cause: S/W bug.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Perform the following in sequence • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Update to the latest F/W. 4. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 117-315
- Description: EEPROM Driver Error Cause: EEPROM Driver program error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W.
- Code: 117-321
- Description: Device Memory Error Cause: SD CARD Type Invalid.
- Troubleshooting Guides: 1 Is the regular SD CARD used? Go to Step 2. Use the regular SD CARD 2 Is the Connector (P/J221) between the SD CARD and the ESS PWB free of broken/bent pins, foreign substances, burns, and etc., and is the unit installed properly? Go to Step 3. Reinstall the SD CARD 3 • Replace the SD CARD. • Does an error occur? Replace (ESS PWB) Troubleshooting complete.
- Code: 117-331
- Description: IPS Error Cause: In relation to IPS, the following internal error has occurred. • OS function return value error • DSP program load fail
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 117-338
- Description: Enable Device Memory Error Cause: Invalid, although SD CARD was detected. This error will be outputted if SD CARD is removed where the power is on.
- Troubleshooting Guides: 1 Is the Connector (P/J221) between the SD CARD and the ESS PWB free of broken/bent pins, foreign substances, burns, and etc., and is the unit installed properly? Replace the SD CARD. Reinstall the SD CARD
- Code: 117-340
- Description: Controller Error Cause: HOOK task error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs, then update to the latest F/W. 2. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 117-344
- Description: FAX Error Cause: FLASHFILE task error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs, then update to the latest F/W. 2. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 117-350
- Description: Controller Error Cause: Task initialization (start) error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 117-361
- Description: IIT Parameter Verify NG Cause: IIT registration adjustment value verification NG. (Checked only at production process)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W.
- Code: 117-362
- Description: EEPROM Sum Check Error Cause: EEPROM sum check value error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W.
- Code: 117-363
- Description: NVM Sum Check Error Cause: NVM sum check value error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W.
- Code: 117-365
- Description: Low Voltage Cause: RTC detected Low Voltage. RTC clock setting and content of SRAM are invalid. Initialize them.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 117-367
- Description: FXIF error Cause: An error occurred on FXIF (such as the Video Underrun error).
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Then update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (ESS PWB) • (IIT Assembly)
- Code: 118-311
- Description: Google Cloud Print Software Error Cause: A critical internal error has occurred.
- Troubleshooting Guides: 1. Check the settings, and try again. 2. Contact customer support if the issue reoccurs. 3. Perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 4. Update to the latest F/W. 5. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 123-314
- Description: Panel Power On Error Cause: Communication error at panel power on. Startup sequence does not start from AIOC within 1 minute after panel power on.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 123-333
- Description: Panel FW transmission error Cause: An error which occurred when the Panel Main FW transmission was performed from ESS.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 123-399
- Description: Panel Device Reboot Error Cause: An error which was caused by an unexpected reboot, such as reboot due to static electricity.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs, then update to the latest F/W. 2. If the problem cannot be solved, replace (Control Panel (3610)) (Control Panel (3615))
- Code: 131-397
- Description: File2Net Fatal Error Cause: File2Net fatal error. S/W bug.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Perform the following in sequence • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Update to the latest F/W. 4. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace (ESS PWB).
- Code: 131-398
- Description: SMB client Fatal Error Cause: SMB Client fatal error.
- Troubleshooting Guides: 1. Turn the power Off and On, perform the same operation and check whether the problem is reoccurring. 2. If the problem still persists, perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 131-399
- Description: FTP client Fatal Error Cause: FTP Client fatal error.
- Troubleshooting Guides: 1. Turn the power Off and On, perform the same operation and check whether the problem is reoccurring. 2. If the problem still persists, perform the following in sequence. • ‘ Network System Fault Check’ • ‘ Network-related Details Check Flow’ 3. Take corrective actions at the host side.
- Code: 133-231
- Description: T_FAXCOM Data Receive I/F Error Cause: T_FAXCOM<->Data processing I/F error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs, then update to the latest F/W. 2. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-234
- Description: JBIG Parameter Error Cause: JBIG parameter error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-235
- Description: MHR Parameter Error Cause: MHR parameter error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-236
- Description: MHR Encode Error Cause: MHR encode error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-237
- Description: MHR Input Buffer Error Cause: Data error of MHR input buffer.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-238
- Description: MHR Output Buffer Error Cause: Data error of MHR output buffer.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-239
- Description: FAX ECM Buffer Address Error Cause: At FAX send/receive, address to get from and write in ECM buffer is wrong.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-240
- Description: Resolution Change Error Cause: Resolution error in FAX send resolution conversion.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-241
- Description: Memory Pool Get Error Cause: Memory pool get error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-242
- Description: Memory Pool Release Error Cause: Memory pool release error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-243
- Description: Message Send Error Cause: Message send error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-244
- Description: Message Receive Error Cause: Message receive error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-246
- Description: Memory Pool Get Error Cause: Memory pool get error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-247
- Description: Message Send Error Cause: Message send error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-248
- Description: Memory Pool Release Error Cause: Memory pool release error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-249
- Description: Message Receive Error Cause: Message receive error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-251
- Description: File Open Error Cause: File open error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-252
- Description: File Close Error Cause: File close error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-253
- Description: File Erase Error Cause: File erase error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-254
- Description: Memory Full Cause: Cannot secure memory necessary to print.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-259
- Description: OS Call Error Cause: OS Call error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-260
- Description: File Open Error Cause: File open error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-261, 133-269
- Description: File Close Error Cause: File close error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-271
- Description: Memory Pool Get Error Cause: Memory pool get error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-272
- Description: Message Send Error Cause: Message send error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-273
- Description: Memory Pool Release Error Cause: Memory pool release error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-274
- Description: Message Receive Error Cause: Message receive error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-275
- Description: OS Call Error Cause: OS Call error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-276
- Description: File Open Error Cause: File open error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-277
- Description: File Close Error Cause: File close error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-278
- Description: File Erase Error Cause: File erase error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-279
- Description: FAX CODEC I/F Error Cause: FAX CODEC I/F error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Check the telephone line connection. Reconnect the telephone line connector. 3. Check the sending side fax. Receive the fax data from a good fax machine. 4. Update to the latest F/W. 5. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-280
- Description: ERR_FAX_TIME Cause: FAX timer error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 133-281
- Description: Power Off Report Create Fail Cause: Failed in creating power-off report.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-282
- Description: Memory Pool Get Error Cause: Memory pool get error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-283
- Description: Message Send Error Cause: Message send error. (OS error)
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-286
- Description: OS Call Error Cause: OS Call error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-287
- Description: File Open Error Cause: File open error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-288
- Description: File Close Error Cause: File close error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-289
- Description: File Erase Error Cause: File erase error.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Update to the latest F/W. 3. If the problem cannot be solved, replace (ESS PWB).
- Code: 133-290
- Description: Print Decode Error Cause: At JBIG data print decode, decode error occurred three successive times.
- Troubleshooting Guides: 1. Turn the power Off and On to check that the error recurs. 2. Check the telephone line connection. Reconnect the telephone line connector. 3. Check the sending side fax. Receive the fax data from a good fax machine. 4. Update to the latest F/W. 5. If the error persists, ensure that the error is replicated after the printer is powered Off and then On, and then replace the following parts in sequence. • (Fax PWB) • (ESS PWB)
- Code: 142-700
- Description: IOT Over Heat Forced Half Speed Cause: Half-speed operation was forced due to abnormally high temperature inside the IOT.
- Troubleshooting Guides: 1. No action is required. 2. Start the operation after the Printer has cooled down.
– About get help with reseting Epson inkpad or others, click here
– Get more information about Epson XP 15000 troubleshooting, click here
Xerox printer reset software introduction:
Notes before resetting Xerox printer:
– Identify accurate version, serial and crum of Xerox printer.
– How to get Xerox printer model info: Click Here
– Before you continue with the reprogramming of the firmware, please make sure that the device is installed on your computer.
– It is very important that under no circumstances should you remove the chip from the cartridge while reprogramming the firmware. After you have succesfully reprogrammed the printer, remove the chip from the cartridge and store it somewhere safely (the chip – a key). In all cartridges which you are going to use in the printer, the chip has to be either removed or sealed. If you have accidently inserted a new cartridge without removing the chip, the device will be blocked. In order to unblock it, you can use the stored chip as a key which help you to unblock the printer.
– And make sure that any other devices (except mouse and keyboard), which are connected to your computer via USB or LPT ports are disconnected. It’s preferable that the computer is connected to the “UPS” (uninterruptible power source) device, because if during the reprogramming process the electricity source has any interruptions, then the reprogramming will be carried out with an error, which makes the device unable to work.
– This firmware will be installed directly to your printer. Before opening firmare link make sure that printer is turned on and connected to your computer and printer drivers are installed correctly.
Be aware that with the reprogramming of the firmware the manufacturer’s warranty goes lost!!
How To Run Firmware Fix Xerox printer
1. Connect the printer to the computer and turn it on.
2. Wait until the printer is ready for work.
3. Drag and drop *.hd to usbprns2.exe file.
4. The reprogramming process starts automatically.
5. Wait until the printer reprograms (10-20 minute) and restarts.
6. After that the reprogramming process is finished, restart the printer.
– Fix Xerox B205 Toner Empty Error, click here
Contact us to get support with Xerox WorkCentre 3615 Error case
Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.
Поиск и устр. неиспр.
148
Многофункциональный черно-белый принтер Xerox
®
WorkCentre
®
3615
Руководство пользователя
Застревание бумаги
В этом разделе рассматриваются следующие вопросы.
•
Нахождение застрявшей бумаги ………………………………………………………………………………………………………….. 148
•
•
Извлечение застрявшей бумаги …………………………………………………………………………………………………………… 150
•
Устранение застреваний бумаги ………………………………………………………………………………………………………….. 161
•
Проблемы с качеством печати ……………………………………………………………………………………………………………… 163
•
•
Проблемы при работе с факсом …………………………………………………………………………………………………………… 169
Нахождение застрявшей бумаги
ПРЕДУПРЕЖДЕНИЕ.
Не касайтесь зоны с наклейками на нагревательном валу и вблизи него
во фьюзере. Можно получить ожог. Если лист бумаги намотался на нагревательный вал, не
пытайтесь удалить его сразу. Выключите принтер и подождите 40 минут, пока остынет
фьюзер. После охлаждения принтера попробуйте извлечь застрявшую бумагу. Если ошибку
устранить не удается, обратитесь в представительство Xerox.
ВНИМАНИЕ!
При вытаскивании застрявшей бумаги не пользуйтесь подручными средствами
и инструментами. Это может привести к неустранимому повреждению принтера.
Ниже указаны участки, где может застревать бумага.
1. Лоток 2
2. Дуплексный автоматический податчик оригиналов
3. Фьюзер
4. Обходной лоток
5. Лоток 1
Поиск и устр. неиспр.
Многофункциональный черно-белый принтер Xerox
®
WorkCentre
®
3615 145
Руководство пользователя
Возможные причины
Решения
Принтер подключен к источнику
бесперебойного питания.
Выключите принтер и вставьте вилку шнура питания в
подходящую розетку.
Принтер подключен к разветвителю
питания вместе с другими
электроприборами большой мощности.
Подключите принтер к розетке напрямую или через
разветвитель питания, к которому не подключены другие
электроприборы большой мощности.
Принтер не печатает
Возможные причины
Решения
Ошибка принтера.
Для сброса ошибки следуйте указаниям на экране. Если ошибку
устранить не удается, обратитесь в представительство Xerox.
В принтере нет бумаги.
Вложите бумагу в лоток.
В картридже закончился тонер.
Замените пустой тонер-картридж.
Мигает индикатор ошибки.
•
Для сброса ошибки следуйте указаниям на экране.
•
Если индикатор готовности не светится, значит работа
принтера прекращена. Выключите и снова включите
принтер. Если ошибку устранить не удается, обратитесь в
представительство Xerox.
Не горят оба индикатора на панели
управления.
Выключите принтер; убедитесь, что шнур питания правильно
вставлен в принтер и в розетку и снова включите принтер. Если
ошибку устранить не удается, обратитесь в представительство
Xerox.
Принтер занят.
•
Если мигает индикатор готовности, то это не ошибка.
Причиной может быть проблема с предыдущей работой
печати. Удалите все работы в очереди печати с помощью
свойств принтера.
•
Загрузите бумагу в лоток.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте Ethernet-подключение между принтером и
компьютером.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте USB-подключение между принтером и
компьютером. Выключите и снова включите принтер.
Кабель принтера не подключен.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте USB-подключение между принтером и
компьютером.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте Ethernet-подключение между принтером и
компьютером.
В данной таблице предоставлены коды сброса ошибок популярных моделей аппаратов разных производителей. В левой колонке указана модель аппарата, в правой — метод сброса. Для большинства моделей данной фирмы вход в сервисный режим одинаков — удерживая «0» включить агрегат.
Другие способы входа в сервисный режим
Xerox 5845, 5855 | Либо включить аппарат с одновременно нажатыми кнопками [Прерывание] и [2] либо на включенном аппарате нажать и удерживать эти кнопки более 2 сек. Если аппарат неисправен — вход осуществляется кнопками [Прерывание] и [5], с ограничением функций (последовательно появляющиеся сообщения о неисправностях сбрасываются двойным нажатием клавиши [Стоп]). Далее аппарат запрашивает четырёхзначный код доступа: это либо 8765 (по умолчанию), либо последние четыре цифры счётчика копий в обратном порядке (если счётчик копий показывает 01234567 — код входа 7654). |
Xerox N17 24/32/40 3225/4025 |
Есть 3 диагностических режима: 1 — проверяются выключатели, датчики и выводятся параметры фьюзера; вход: (2+6), после «IOT?» нажать «7»; 2 — печатается тест-лист «сетка» в симплексе или дуплексе; вход: (2+6), после «IOT?» нажать «4»; 3 — меняются параметры и настройки принтера (NVRAM); вход: (2+6), после «IOT?» нажать (4+7), «7» сразу же отпустить; «4» держать до появления «3» на дисплее, затем отпустить. |
XD102. 155 XE60. 84 XC800. 1255 |
stop – auto – stop – auto иногда записывают как C – Density select – C – Density select (что то же самое) |
WC PE 16(e) | набираем на клавиатуре [menu] — [#] — [1934] — [menu]; после входа в сервисное меню появится надпись «TECH» |
Для выхода из режима дважды нажимаем кнопку «Сброс» или выключаем и снова включаем аппарат.
Возможные проблемы
Xerox 5201/5203/5305/5306 XC351/355/356 | Обнуление счетчика фоторецептора. Признак — моргают все лампы, в готовность не выходит.
|
Xerox ХC520/540/560/580 | Сброс ошибки Н3/Н4.
|
Xerox N17, N2125 24/32/40 3225/4025 N2025/2825 Phaser 5400 |
Эти модели имеют счетчик фьюзера. По его окончании аппарат просит заменить набор регламентных работ или «Maintenance Kit». Этот счетчик тоже можно сбросить, если печка в порядке: (2+6), вкл. питание, дождаться «IOT?», не позднее 5 сек. после появления «IOT?» нажать (0+5) и держать до появления сообщения о сбросе «Reset Complete. Please Reboot». Выключите и включите принтер. Рекомендация: все же лучше не просто сбрасывать счетчик, а устанавливать набор, в который входят фьюзер в сборе, ролик переноса, ролики подачи (6 или 15), протирочная салфетка |
WC РE16(e)
Samsung SCX 4016/4116/4216(F) |
Сброс сообщения «Нет тонера» после заправки — есть два варианта: 1. Поставить в паз на передней части картриджа предохранитель на 1/16А (0.0625А), при первом же включении аппарат пережгёт предохранитель и сообщение сбросится. Известны случаи, что работало и с предохранителем до 0.5А; но если МФУ предохранитель не сможет сжечь, будет ошибка CRU FUSE ERROR, которая уходит после установки более слабого предохранителя. 2. Через сервисное меню: для входа в сервисное меню 4216/PE16 набираем на клавиатуре : [menu] — [#] — 1934 — [menu], (для 4016/4116 — [menu] — [upper level] — [Стрелка влево] — [Стрелка вправо] — [upper level] — [enter]). После входа в сервисное меню появится надпись TECH; с помощью клавиш [Стрелка влево] — [Стрелка вправо] находим запись «New cartridge», выбираем «Yes». Для выхода из сервисного меню просто выключаем и включаем МФУ (или для 4216/PE16 набираем на клавиатуре [menu] — [#] — 1934). |
Xerox 4030 | Процедура одинакова для обоих картриджей: удерживая кнопку сброса, находящуюся рядом со шнуром питания; включите принтер. |
Xerox 5017/5316/5317 | Сброс барабана (ошибка J7): на платке с EPROM запаиваем F2, а вместо F1 включаем тестер в режиме измерения тока на пределе 3 mA с защитой. Делаем 101 копию, и – привет! |
DC 212/214 | Сброс ошибки U4. Войдите в диагностический режим и подождите 30 сек, пока аппарат завершит инициализацию. Введите диагностический код [401] и нажмите кнопку «Старт». Выйдите из диагностики, выключите аппарат. Подождите 10 сек, включите аппарат. Подождите 30 сек. Если код U4 появился снова, повторите процедуру сброса. Если после 3-х процедур код появляется вновь, но Вы уверены в работоспособности фьюзера — замените главную плату. |
WC Pro 320 | Сброс кода U4 (печная ошибка) – код 10-1, введите 0 и нажмите кнопку [Старт] |
WC Pro 610 | Тонер: включите аппарат, откройте крышку; нажмите [MENU], [6], [3], [CLEAR], [ENTER] Барабан: включите аппарат, откройте крышку; нажмите [MENU], [6], [4], [CLEAR], [ENTER] |
XD155df | после сброса счётчика 24-7 в 26-38 пропиши 1 – больше считать не будет. |
XE 60/80 | Сброс OPC Cartridge: при включенном питании откройте переднюю крышку; удерживая кнопку [Copy Contrast], закройте крышку и продолжайте держать кнопку 3 секунды. |
Xerox 5845 | При включении требует ввести пользовательский код или кликнуть администратора. Надо войти в «АДМИНИСТРАТОР» (код 11111), затем ввести новый счет; или заблокировать аудитрон. |
НИКОГДА не используйте никаких других диагностических кодов и процедур, потому что это может привести к непредсказуемым последствиям.
Имейте в виду, что сброс ошибки не гарантирует вас от всех остальных бед, поэтому при первой же возможности завезите копировальный аппарат в сервисную фирму, чтобы там удалили отработку, произвели необходимую чистку и регулировки.
Источник
Xerox 3610 сбой датчика атс
Опыта общения с этими аппаратами у меня немного, но тем не менее решил поделится тем что знаю.
Есть на обслуживании клиент с двумя аппаратами Xerox WorkCentre 3615DN аппараты обслуживаем чуть больше года. Сразу скажу, что это не клон Samsung, а собственная разработка Xerox. С одной стороны ролики захвата/отделения совместимы со многими аппаратами Xerox, с другой стороны из за бренда Xerox стоимость на ЗИП зашкаливает. Аппарат не смотря на невысокую стоимость печатает со скоростью 47 страниц в минуту, что для столь низкой цены на аппарат просто удивительно. При печати аппарат из за небольшого веса ощутимо подрагивает, прямо как дешевые струйники при печати в черновом режиме. К 100000 копиям были трижды поменяны ролики захвата/подачи. Качество печати аппарата можно оценить, как очень высокое, что неудивительно учитывая, что при двухкомпонентной печати заряд тонера на высоких скоростях производится намного лучше чем в однокомпонентных системах.
Про узел термозакрепления.
115R00085 Узел термозакрепления в сборе Ph3610/WC3615
Узел термозакрепления (она же печка) в Xerox 3610/3615 явно перекачивала с цветников. Для запекания используется тефлоновый вал, а вот вместо вала прижима используется пленка прижима. Я не знаю почему используется вместо вала прижима пленка, но точно могу сказать, что в печках Xerox это наиболее слабое место. В обслуживаемых аппаратах к 110000 копиям у одной печки пленка приказала долго жить. Во втором аппарате печка уже работает со сбоями, периодически вызывая ложные замятия. Ресурс печки официально составляет 200000 копий, что не соответствует реальности. Ценник на печку в 25000
30000 рублей приводит к тому, что после 100000 копий аппарат списывается и компании покупают аппараты другого бренда с более лояльной ценовой политикой.
Про чипы и тонер.
Традиционно картриджи Xerox чипованные, не избежал этой участи и Xerox 3610/3615. В картридже используется ставшим уже визуально привычным по аппаратам Xerox 3010/6010 четырехконтактный чип. Вот только ценник на этот чип составляет неожиданно много около 1400 рублей. С тонером для заправки картриджей все одновременно проще и сложнее. Тонер используется стандартный отрицательно заряженный, но вот как оказалось недорогой двухкомпонентный тонер от Xerox Phaser 5500 не подошел (бледная печать). После серии экспериментов оказалось, что засыпать нужно тонер от цветных принтеров Xerox типа 7500/7800 и т.д. Учитывая выше написанное ценник на заправку Xerox WorkCentre 3615DN для клиента получается от 4500 до 5500 рублей в зависимости от курса доллара и поставщика тонеров и чипа.
Подводя итоги.
Аппарат мне понравился своей скоростью и пожалуй безглючностью в плане софта, но вот при первой же относительно серьезной поломке аппарат придется списывать. На мой взгляд этот аппарат ни никак не тянет на замену Xerox Phaser 3635. За эти деньги лучше приобрести HP LaserJet Pro MFP M521dn или на крайний случай Kyocera ECOSYS M3040idn. Xerox WorkCentre 3615DN идеально подойдет для клиентского офиса где мало печатают, но нужно “пустить пыль в глаза”.
Оцените качество заметки
100 комментариев
Добрый день, объем картриджа какой, на сколько листов? При таком ценнике на расходку мфу нужно списывать сразу после покупки, а на сэкономленные деньги покупать что-то адекватное.
“нужно пустить пыль в глаза” – верно подмечено.
Это пожалуй главный принцип работы фирмы Xerox за последние лет так 10-15.
уважаемый коллега, ресурс печки составляет 200.000 копий по паспорту Xerox и в случае выхода из строя ранее, заменяется в рамках гарантии.
вы вероятно путаете с барабаном, ресурс которого составляет 85.000 копий и стоимость которого 7000 рублей.
Спасибо за информацию, но печка 200000 не пробежит. Что касается гарантийной замены печки, то это миф. Позвоните на горячую линию Xerox и с удивлением обнаружите, что на печки, ролики, картриджи Xerox гарантию не предоставляет.
Кстати, а есть сервис-мануал от этой серии? может там какие запчасти в печке написаны.
Мануала нет, но зная политику Xerox уверен, что печки отгружаются только в сборе
Именно так) Печки только в сборе , и действительно первые партии печек зачастую ходили от 30-65 тысяч, после глобальных замен по гарантии, стали ходить 100-120к максимум) и уже сложно доказать что по гарантии, так как ссылаются на качество бумаги* не Xerox***
Фьюзер является ресурсным материалом, реурс в 200К стр. ожидаемым, уши от дохлого осла вы получите от Xeroxса
а не печку по гарантии
Уважаемый коллега. Печка это ресурсный материал, а ресурсные материалы не подлежат замене в рамках гарантии фирмы Xerox. У меня таких уже 4! печки, из парка в 10 шт.
На первых двух трещина в корпусе на 30 тысячах, два вторых прошли 50 и 60 тысяч. Проблема в прижимной пленке (вале).
Вместо них восстанавливаем старые проверенные 3600.
и у меня была не долгой радость :
Достоинства:
Быстрый, легко и гибко настраивается. Не разу не зажевал бумагу. Удобная, быстрая заправка огромной оригинальной тубой с тонером.
Недостатки:
ближе к 200 тыс пробега порвался пленочный тефлоновый вал в печке(фьюзере), или специально пленка перетерлась:) Узел фьюзер одноразовый, заменяется в сборе Код: 115R00085 цена на 07.09.2015 от 30 тыс руб до 34 тыс.руб . Других вариантов ремонта не нашел.
Короче, покупая аппарат , готовьтесь его выбросить ближе к окончанию срока эксплуатации печки( по документам ресурс печки 200 тысяч копий)
В Рамисе есть тонер именно под эти модели “Тонер XEROX Phaser 3610/WC 3615/3655 (фл,290,14К) Silver ATM” – вы не пробовали такой? По цене всё-таки гуманней, чем от цветников 7500…
Меня смущает ценник на тонер, ну не может химический двухкомпонентный тонер стоить так мало.
а собственная разработка Xerox
Вы уверенны?
аппарат списывается и компании покупают аппараты другого бренда с более лояльной ценовой политикой.
Например?
Откуда такой скепсис? Вы знаете чья это разработка? Я считаю, что это разработка Xerox потому что, в аппарате использованы детали от других аппаратов разработанные непосредственно Xerox. Что касается реальных конкурентов этого аппарата, которые более ремонтопригодны и имеют гораздо более низкую стоимость копии то вот они: HP LaserJet Enterprise 500 MFP M525dn, Kyocera ECOSYS M3040idn
А можно ли сбросить ошибку 091-913 замена принт-катриджа.
Я бы не назвал это ошибкой, просто закончился ресурс драм-картриджа по чипу. Если драм в хорошем состоянии, то можно сбросить счетчик путем замены чипа, если конечно Вас не смущает ценник в 2500
МФУ Xerox WorkCentre 3615 DN выдает ошибку 091-913. Менял барабан и тонер картридж не помогает. Снял барабан с тонер картриджем поставил на другой МФУ – работает. Снял работающий барабан и тонер-картридж поставил на первую машину которая выдавала ошибку выдает ту же ошибку 091-913. дело не в барабане и тонер- картридже. Дело в другом. Вчем. Что надо сделать чтобы убрать ошибку?
Чип совместимый или оригинал. Версии прошивки у аппаратов одинаковые?
Добрый день/вечер!
Подскажите, какие тонера пробовали (и, в частности – от 700 серии может ли подойти?), и какой вес засыпается.
Я пробовал засыпать только минольтовский тонер TN-615. Сначала был небольшой фон. потом все нормализовалось.
Подтверждаю слова автора, данная модель имеет “с завода” дефектный узел “фьюзер” (печку).
Нам сказали в сервисном центре Xerox, что при комплектации заводской печкой, были использованы не термостойкие элементы, поэтому большое задание при печати может расплавить пластмассовые элементы фьюзера и привести к его спеканию.
При выполнении гарантийных работ, фьюзер меняют на новый тип, в котором установлены термостойкие элементы!
А есть ли какой-нибудь бюллетень сервисный на этот случай, чтобы понимать, – с каких серийных номеров или месяца выпуска – пошли нормальные термоузлы?
Уважаемые коллеги. Дайте пожалуйста телефон организации, которая в случае гарантийного аппарата меняет фьюзер.
С большим удовольствием отвезу туда 4 таких аппарата.
Это Epson WorkForce AL-M400DN со сканером. Xerox не делает аппараты А4 формата
Хотите сказать, что Epson при разработке аппаратов берет за основу запчасти от принтеров Xerox-? Вам не кажется это бредом?
Ухх, как все глухо у заправщиков. Какие именно запчасти вы считаете запчастями Xerox-а?
С чего Вы решили, что общаетесь с заправщиками? Вообще то Вы переписываетесь с инженером, что касается запчастей и прочего, то это Вы мне покажите парт номер детали разработанной Epson или хотя бы скрин партномеров из сервис-мануала. В будущем, если что пишете, то не голословно, а с доказательствами, а так только вводите в заблуждение посетителей блога.
В будущем, если что пишете, то не голословно, а с доказательствами, а так только вводите в заблуждение посетителей блога.
===
Подождите, подождите, вот ваше утверждение или чье. 17.01.2016 к 3:24 пп cказал :
Откуда такой скепсис? Вы знаете чья это разработка? Я считаю, что это разработка Xerox потому что, в аппарате использованы детали от других аппаратов разработанные непосредственно Xerox.
==============
Вот я у вас и спрашиваю: какие именно детали от других аппаратов разработанные непосредственно Xerox? Я знаю, что кроме CQ все аппараты у Xerox A4 формата или Samsung или Epson – зря ссылку удалили, сами прочтите, специально для инженеров писал. Даже если я вам скину партномер, что это изменит? Принадлежность разработки, можно посмотреть по стоимости ЗИП-а, у Epson на этот принтер все в 2 раза дешевле, по аналогии HP/Canon.
Покупать HP LaserJet Enterprise 500 MFP M525dn маразм, так как это Canon LBP 6750/6780. На Canon оригинальный зип в два раза дешевле стоит, чем у HP, так как HP тупо покупает у Canon и продает в два раза дороже. Вот и весь бизнес у HP.
Самое интересное сейчас МФУ А4 формата это Canon iR 1435/1435i/1435iF, картридж гигантский, заправлять можно оригиналом 3764B002, тонер не чипованный.
То, что у Canon аппараты дешевле это факт, но вот софт у Canon откровенное “Г”. У аппаратов Canon нет такого понятия как процент оставшегося тонера. У него есть два статуса “все хорошо” и “замените картридж”. Для аппаратов в корпоративном секторе это просто неприемлемо. Что касается МФУ Canon iR 1435, то Вы забыли упомянуть, что тубы у них чипованные и чипы там стоят такие же как в HP M252 и первая же заправка лишает аппарат гарантии. К тому же нет данных, аппарат все таки блокируется после определенного количества страниц или все ограничивается надоедливым замечанием об использовании неоригинальных расходных материалов.
1) Где вы у 9436B002 увидели чип.
2) Любая заправка лишает гарантии, зачем вы это написали? Если в HP сыпать тонер от KM то с гарантией все ок? Так что ли? =)))
3) возможность посмотреть информацию об оставшемся тонере есть: OK, Низкий (8%) и Нет. Что еще нужно?
Все остальное верно только для вашего HP M252.
В любом принтере/мфу софт на любителя, кому-то нравится HP, кому то Kyocera, кого-то тошнит от KDPL у всех свои предпочтения.
По Вашему статусы “ОК” / “мало тонера” / “замените тонер” – информативно? Вот теперь представьте, что готовите срочный отчет и Вам необходимо распечатать несколько тысяч страниц. В статусе стоит “ОК”, а по факту в тубе всего 11% тонера в остатке, конечно Вам не хватить этого ресурса и отчет не распечатается. Именно поэтому я писал, что в корпоративном сегменте, это неприемлемо.
Если Вы считаете, что в Canon нет чипа, то скажите мне что же изображено на фотографии?
Думаю, что да, информации о 8% достаточно. Нормальные организации держат некоторый запас тонера в офисе, хотя бы еще одну тубу, когда вставляют последнюю, заказывают еще 1-5 шт. – и это нормально, так и должно быть, а у совсем грамотных – есть еще и запасной драм с печкой. Зная, что вполне может возникнуть потребность много печатать и не иметь запаса по расходным материалам – глупо, а у тех у кого эта потребность возникла разово, не поможет не 11%, не 15%, не 17% – все равно побегут срочно искать.
Я не знаю, что это за туба на фотографии – у С-EXV 50 чипа нет.
Поискал фотографии — да, что-то есть, не знаю чип это или нет. У меня знакомый человек у которого этот аппарат стоит — сказал, что чипа нет.
Знакомому, рекомендую быть внимательней. И пусть он объяснит Вам, почему при заправке картриджа выскакивает вот такое сообщение “Невозможно правильно определить информацию об уровне тонера. Возможно, отсутствует картридж или вставлен картридж, произведенный не Canon или имеющий неверный номер. Продолжить: Нажмите OK Отмена: Нажмите кнопку останова”
Что касается запаса расходных материалов, то не забывайте, что в России несколько другой менталитет и все экономят каждую копейку. Аппарат изначально сильно бюджетный, и никто под него гору расходных материалов держать не будет.
Что касается фотки, то это C-EXV50, учитесь пока Вам дают бесплатную и главное “ДОСТОВЕРНУЮ” информацию.
Ну так это и HP вашего касается, нет? Ни кто под него запас держать не будет и то, что вы тут про отчет пишите верно для любого аппарата.
3610/3615 – не является разработкой Xerox, сотрите эту информацию и не вводите людей в заблуждение. Учитесь пока вам дают бесплатную и главное «ДОСТОВЕРНУЮ» информацию.
Я выше писал Вам, чтобы вы при утверждении, подкрепляли свою информацию доказательствами. Да и с каких пор Epson стал разрабатывать лазерники? Мне казалось их попытки разрабатывать технику закончились на аппарате Epson c1100.
Будте так любезны подтвердите свою информацию. 3610/3615 является раразобткой Xerox, а потом прочсите этого от других. Я вам все объяснил.
НорУдобный тут у вас коментарии =))))))ма
Canon iR 1435/1435i/1435iF печка тоже стоит столько что вместо замены печки выгоднее купить новый аппарат
Поискал фотографии – да, что-то есть, не знаю чип это или нет. У меня знакомый человек у которого этот аппарат стоит – сказал, что чипа нет.
Ну вот Вам на затравку. Ролики захвата и отделения используются те же что и в аппаратах Xerox 6600/6180/6280. Конструкция лотка классическая Xerox. Веб панель используется классическая Xerox. Общие инженерные решения использованные в аппарате использованы от цветных аппаратов Xerox. Тонер и девелопер используются от цветников Xerox. Чипы тоже использованы от цветников Xerox.
Вот Вам мои доводы, а теперь жду Ваших доводов. На платах нет ни слова про Epson, все партномера родные Xerox.
Источник
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Поиск и устр. неиспр.
Многофункциональный черно-белый принтер Xerox
®
WorkCentre
®
3615 145
Руководство пользователя
Возможные причины
Решения
Принтер подключен к источнику
бесперебойного питания.
Выключите принтер и вставьте вилку шнура питания в
подходящую розетку.
Принтер подключен к разветвителю
питания вместе с другими
электроприборами большой мощности.
Подключите принтер к розетке напрямую или через
разветвитель питания, к которому не подключены другие
электроприборы большой мощности.
Принтер не печатает
Возможные причины
Решения
Ошибка принтера.
Для сброса ошибки следуйте указаниям на экране. Если ошибку
устранить не удается, обратитесь в представительство Xerox.
В принтере нет бумаги.
Вложите бумагу в лоток.
В картридже закончился тонер.
Замените пустой тонер-картридж.
Мигает индикатор ошибки.
•
Для сброса ошибки следуйте указаниям на экране.
•
Если индикатор готовности не светится, значит работа
принтера прекращена. Выключите и снова включите
принтер. Если ошибку устранить не удается, обратитесь в
представительство Xerox.
Не горят оба индикатора на панели
управления.
Выключите принтер; убедитесь, что шнур питания правильно
вставлен в принтер и в розетку и снова включите принтер. Если
ошибку устранить не удается, обратитесь в представительство
Xerox.
Принтер занят.
•
Если мигает индикатор готовности, то это не ошибка.
Причиной может быть проблема с предыдущей работой
печати. Удалите все работы в очереди печати с помощью
свойств принтера.
•
Загрузите бумагу в лоток.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте Ethernet-подключение между принтером и
компьютером.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте USB-подключение между принтером и
компьютером. Выключите и снова включите принтер.
Кабель принтера не подключен.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте USB-подключение между принтером и
компьютером.
•
Если после отправки работы печати индикатор готовности не
мигает, проверьте Ethernet-подключение между принтером и
компьютером.
В данной таблице предоставлены коды сброса ошибок популярных моделей аппаратов разных производителей. В левой колонке указана модель аппарата, в правой — метод сброса. Для большинства моделей данной фирмы вход в сервисный режим одинаков — удерживая «0» включить агрегат.
Другие способы входа в сервисный режим
Xerox 5845, 5855 | Либо включить аппарат с одновременно нажатыми кнопками [Прерывание] и [2] либо на включенном аппарате нажать и удерживать эти кнопки более 2 сек. Если аппарат неисправен — вход осуществляется кнопками [Прерывание] и [5], с ограничением функций (последовательно появляющиеся сообщения о неисправностях сбрасываются двойным нажатием клавиши [Стоп]). Далее аппарат запрашивает четырёхзначный код доступа: это либо 8765 (по умолчанию), либо последние четыре цифры счётчика копий в обратном порядке (если счётчик копий показывает 01234567 — код входа 7654). |
Xerox N17 24/32/40 3225/4025 |
Есть 3 диагностических режима: 1 — проверяются выключатели, датчики и выводятся параметры фьюзера; вход: (2+6), после «IOT?» нажать «7»; 2 — печатается тест-лист «сетка» в симплексе или дуплексе; вход: (2+6), после «IOT?» нажать «4»; 3 — меняются параметры и настройки принтера (NVRAM); вход: (2+6), после «IOT?» нажать (4+7), «7» сразу же отпустить; «4» держать до появления «3» на дисплее, затем отпустить. |
XD102. 155 XE60. 84 XC800. 1255 |
stop – auto – stop – auto иногда записывают как C – Density select – C – Density select (что то же самое) |
WC PE 16(e) | набираем на клавиатуре [menu] — [#] — [1934] — [menu]; после входа в сервисное меню появится надпись «TECH» |
Для выхода из режима дважды нажимаем кнопку «Сброс» или выключаем и снова включаем аппарат.
Возможные проблемы
Xerox 5201/5203/5305/5306 XC351/355/356 | Обнуление счетчика фоторецептора. Признак — моргают все лампы, в готовность не выходит.
|
Xerox ХC520/540/560/580 | Сброс ошибки Н3/Н4.
|
Xerox N17, N2125 24/32/40 3225/4025 N2025/2825 Phaser 5400 |
Эти модели имеют счетчик фьюзера. По его окончании аппарат просит заменить набор регламентных работ или «Maintenance Kit». Этот счетчик тоже можно сбросить, если печка в порядке: (2+6), вкл. питание, дождаться «IOT?», не позднее 5 сек. после появления «IOT?» нажать (0+5) и держать до появления сообщения о сбросе «Reset Complete. Please Reboot». Выключите и включите принтер. Рекомендация: все же лучше не просто сбрасывать счетчик, а устанавливать набор, в который входят фьюзер в сборе, ролик переноса, ролики подачи (6 или 15), протирочная салфетка |
WC РE16(e)
Samsung SCX 4016/4116/4216(F) |
Сброс сообщения «Нет тонера» после заправки — есть два варианта: 1. Поставить в паз на передней части картриджа предохранитель на 1/16А (0.0625А), при первом же включении аппарат пережгёт предохранитель и сообщение сбросится. Известны случаи, что работало и с предохранителем до 0.5А; но если МФУ предохранитель не сможет сжечь, будет ошибка CRU FUSE ERROR, которая уходит после установки более слабого предохранителя. 2. Через сервисное меню: для входа в сервисное меню 4216/PE16 набираем на клавиатуре : [menu] — [#] — 1934 — [menu], (для 4016/4116 — [menu] — [upper level] — [Стрелка влево] — [Стрелка вправо] — [upper level] — [enter]). После входа в сервисное меню появится надпись TECH; с помощью клавиш [Стрелка влево] — [Стрелка вправо] находим запись «New cartridge», выбираем «Yes». Для выхода из сервисного меню просто выключаем и включаем МФУ (или для 4216/PE16 набираем на клавиатуре [menu] — [#] — 1934). |
Xerox 4030 | Процедура одинакова для обоих картриджей: удерживая кнопку сброса, находящуюся рядом со шнуром питания; включите принтер. |
Xerox 5017/5316/5317 | Сброс барабана (ошибка J7): на платке с EPROM запаиваем F2, а вместо F1 включаем тестер в режиме измерения тока на пределе 3 mA с защитой. Делаем 101 копию, и – привет! |
DC 212/214 | Сброс ошибки U4. Войдите в диагностический режим и подождите 30 сек, пока аппарат завершит инициализацию. Введите диагностический код [401] и нажмите кнопку «Старт». Выйдите из диагностики, выключите аппарат. Подождите 10 сек, включите аппарат. Подождите 30 сек. Если код U4 появился снова, повторите процедуру сброса. Если после 3-х процедур код появляется вновь, но Вы уверены в работоспособности фьюзера — замените главную плату. |
WC Pro 320 | Сброс кода U4 (печная ошибка) – код 10-1, введите 0 и нажмите кнопку [Старт] |
WC Pro 610 | Тонер: включите аппарат, откройте крышку; нажмите [MENU], [6], [3], [CLEAR], [ENTER] Барабан: включите аппарат, откройте крышку; нажмите [MENU], [6], [4], [CLEAR], [ENTER] |
XD155df | после сброса счётчика 24-7 в 26-38 пропиши 1 – больше считать не будет. |
XE 60/80 | Сброс OPC Cartridge: при включенном питании откройте переднюю крышку; удерживая кнопку [Copy Contrast], закройте крышку и продолжайте держать кнопку 3 секунды. |
Xerox 5845 | При включении требует ввести пользовательский код или кликнуть администратора. Надо войти в «АДМИНИСТРАТОР» (код 11111), затем ввести новый счет; или заблокировать аудитрон. |
НИКОГДА не используйте никаких других диагностических кодов и процедур, потому что это может привести к непредсказуемым последствиям.
Имейте в виду, что сброс ошибки не гарантирует вас от всех остальных бед, поэтому при первой же возможности завезите копировальный аппарат в сервисную фирму, чтобы там удалили отработку, произвели необходимую чистку и регулировки.
Источник
Xerox 3610 сбой датчика атс
Опыта общения с этими аппаратами у меня немного, но тем не менее решил поделится тем что знаю.
Есть на обслуживании клиент с двумя аппаратами Xerox WorkCentre 3615DN аппараты обслуживаем чуть больше года. Сразу скажу, что это не клон Samsung, а собственная разработка Xerox. С одной стороны ролики захвата/отделения совместимы со многими аппаратами Xerox, с другой стороны из за бренда Xerox стоимость на ЗИП зашкаливает. Аппарат не смотря на невысокую стоимость печатает со скоростью 47 страниц в минуту, что для столь низкой цены на аппарат просто удивительно. При печати аппарат из за небольшого веса ощутимо подрагивает, прямо как дешевые струйники при печати в черновом режиме. К 100000 копиям были трижды поменяны ролики захвата/подачи. Качество печати аппарата можно оценить, как очень высокое, что неудивительно учитывая, что при двухкомпонентной печати заряд тонера на высоких скоростях производится намного лучше чем в однокомпонентных системах.
Про узел термозакрепления.
115R00085 Узел термозакрепления в сборе Ph3610/WC3615
Узел термозакрепления (она же печка) в Xerox 3610/3615 явно перекачивала с цветников. Для запекания используется тефлоновый вал, а вот вместо вала прижима используется пленка прижима. Я не знаю почему используется вместо вала прижима пленка, но точно могу сказать, что в печках Xerox это наиболее слабое место. В обслуживаемых аппаратах к 110000 копиям у одной печки пленка приказала долго жить. Во втором аппарате печка уже работает со сбоями, периодически вызывая ложные замятия. Ресурс печки официально составляет 200000 копий, что не соответствует реальности. Ценник на печку в 25000
30000 рублей приводит к тому, что после 100000 копий аппарат списывается и компании покупают аппараты другого бренда с более лояльной ценовой политикой.
Про чипы и тонер.
Традиционно картриджи Xerox чипованные, не избежал этой участи и Xerox 3610/3615. В картридже используется ставшим уже визуально привычным по аппаратам Xerox 3010/6010 четырехконтактный чип. Вот только ценник на этот чип составляет неожиданно много около 1400 рублей. С тонером для заправки картриджей все одновременно проще и сложнее. Тонер используется стандартный отрицательно заряженный, но вот как оказалось недорогой двухкомпонентный тонер от Xerox Phaser 5500 не подошел (бледная печать). После серии экспериментов оказалось, что засыпать нужно тонер от цветных принтеров Xerox типа 7500/7800 и т.д. Учитывая выше написанное ценник на заправку Xerox WorkCentre 3615DN для клиента получается от 4500 до 5500 рублей в зависимости от курса доллара и поставщика тонеров и чипа.
Подводя итоги.
Аппарат мне понравился своей скоростью и пожалуй безглючностью в плане софта, но вот при первой же относительно серьезной поломке аппарат придется списывать. На мой взгляд этот аппарат ни никак не тянет на замену Xerox Phaser 3635. За эти деньги лучше приобрести HP LaserJet Pro MFP M521dn или на крайний случай Kyocera ECOSYS M3040idn. Xerox WorkCentre 3615DN идеально подойдет для клиентского офиса где мало печатают, но нужно “пустить пыль в глаза”.
Оцените качество заметки
100 комментариев
Добрый день, объем картриджа какой, на сколько листов? При таком ценнике на расходку мфу нужно списывать сразу после покупки, а на сэкономленные деньги покупать что-то адекватное.
“нужно пустить пыль в глаза” – верно подмечено.
Это пожалуй главный принцип работы фирмы Xerox за последние лет так 10-15.
уважаемый коллега, ресурс печки составляет 200.000 копий по паспорту Xerox и в случае выхода из строя ранее, заменяется в рамках гарантии.
вы вероятно путаете с барабаном, ресурс которого составляет 85.000 копий и стоимость которого 7000 рублей.
Спасибо за информацию, но печка 200000 не пробежит. Что касается гарантийной замены печки, то это миф. Позвоните на горячую линию Xerox и с удивлением обнаружите, что на печки, ролики, картриджи Xerox гарантию не предоставляет.
Кстати, а есть сервис-мануал от этой серии? может там какие запчасти в печке написаны.
Мануала нет, но зная политику Xerox уверен, что печки отгружаются только в сборе
Именно так) Печки только в сборе , и действительно первые партии печек зачастую ходили от 30-65 тысяч, после глобальных замен по гарантии, стали ходить 100-120к максимум) и уже сложно доказать что по гарантии, так как ссылаются на качество бумаги* не Xerox***
Фьюзер является ресурсным материалом, реурс в 200К стр. ожидаемым, уши от дохлого осла вы получите от Xeroxса
а не печку по гарантии
Уважаемый коллега. Печка это ресурсный материал, а ресурсные материалы не подлежат замене в рамках гарантии фирмы Xerox. У меня таких уже 4! печки, из парка в 10 шт.
На первых двух трещина в корпусе на 30 тысячах, два вторых прошли 50 и 60 тысяч. Проблема в прижимной пленке (вале).
Вместо них восстанавливаем старые проверенные 3600.
и у меня была не долгой радость :
Достоинства:
Быстрый, легко и гибко настраивается. Не разу не зажевал бумагу. Удобная, быстрая заправка огромной оригинальной тубой с тонером.
Недостатки:
ближе к 200 тыс пробега порвался пленочный тефлоновый вал в печке(фьюзере), или специально пленка перетерлась:) Узел фьюзер одноразовый, заменяется в сборе Код: 115R00085 цена на 07.09.2015 от 30 тыс руб до 34 тыс.руб . Других вариантов ремонта не нашел.
Короче, покупая аппарат , готовьтесь его выбросить ближе к окончанию срока эксплуатации печки( по документам ресурс печки 200 тысяч копий)
В Рамисе есть тонер именно под эти модели “Тонер XEROX Phaser 3610/WC 3615/3655 (фл,290,14К) Silver ATM” – вы не пробовали такой? По цене всё-таки гуманней, чем от цветников 7500…
Меня смущает ценник на тонер, ну не может химический двухкомпонентный тонер стоить так мало.
а собственная разработка Xerox
Вы уверенны?
аппарат списывается и компании покупают аппараты другого бренда с более лояльной ценовой политикой.
Например?
Откуда такой скепсис? Вы знаете чья это разработка? Я считаю, что это разработка Xerox потому что, в аппарате использованы детали от других аппаратов разработанные непосредственно Xerox. Что касается реальных конкурентов этого аппарата, которые более ремонтопригодны и имеют гораздо более низкую стоимость копии то вот они: HP LaserJet Enterprise 500 MFP M525dn, Kyocera ECOSYS M3040idn
А можно ли сбросить ошибку 091-913 замена принт-катриджа.
Я бы не назвал это ошибкой, просто закончился ресурс драм-картриджа по чипу. Если драм в хорошем состоянии, то можно сбросить счетчик путем замены чипа, если конечно Вас не смущает ценник в 2500
МФУ Xerox WorkCentre 3615 DN выдает ошибку 091-913. Менял барабан и тонер картридж не помогает. Снял барабан с тонер картриджем поставил на другой МФУ – работает. Снял работающий барабан и тонер-картридж поставил на первую машину которая выдавала ошибку выдает ту же ошибку 091-913. дело не в барабане и тонер- картридже. Дело в другом. Вчем. Что надо сделать чтобы убрать ошибку?
Чип совместимый или оригинал. Версии прошивки у аппаратов одинаковые?
Добрый день/вечер!
Подскажите, какие тонера пробовали (и, в частности – от 700 серии может ли подойти?), и какой вес засыпается.
Я пробовал засыпать только минольтовский тонер TN-615. Сначала был небольшой фон. потом все нормализовалось.
Подтверждаю слова автора, данная модель имеет “с завода” дефектный узел “фьюзер” (печку).
Нам сказали в сервисном центре Xerox, что при комплектации заводской печкой, были использованы не термостойкие элементы, поэтому большое задание при печати может расплавить пластмассовые элементы фьюзера и привести к его спеканию.
При выполнении гарантийных работ, фьюзер меняют на новый тип, в котором установлены термостойкие элементы!
А есть ли какой-нибудь бюллетень сервисный на этот случай, чтобы понимать, – с каких серийных номеров или месяца выпуска – пошли нормальные термоузлы?
Уважаемые коллеги. Дайте пожалуйста телефон организации, которая в случае гарантийного аппарата меняет фьюзер.
С большим удовольствием отвезу туда 4 таких аппарата.
Это Epson WorkForce AL-M400DN со сканером. Xerox не делает аппараты А4 формата
Хотите сказать, что Epson при разработке аппаратов берет за основу запчасти от принтеров Xerox-? Вам не кажется это бредом?
Ухх, как все глухо у заправщиков. Какие именно запчасти вы считаете запчастями Xerox-а?
С чего Вы решили, что общаетесь с заправщиками? Вообще то Вы переписываетесь с инженером, что касается запчастей и прочего, то это Вы мне покажите парт номер детали разработанной Epson или хотя бы скрин партномеров из сервис-мануала. В будущем, если что пишете, то не голословно, а с доказательствами, а так только вводите в заблуждение посетителей блога.
В будущем, если что пишете, то не голословно, а с доказательствами, а так только вводите в заблуждение посетителей блога.
===
Подождите, подождите, вот ваше утверждение или чье. 17.01.2016 к 3:24 пп cказал :
Откуда такой скепсис? Вы знаете чья это разработка? Я считаю, что это разработка Xerox потому что, в аппарате использованы детали от других аппаратов разработанные непосредственно Xerox.
==============
Вот я у вас и спрашиваю: какие именно детали от других аппаратов разработанные непосредственно Xerox? Я знаю, что кроме CQ все аппараты у Xerox A4 формата или Samsung или Epson – зря ссылку удалили, сами прочтите, специально для инженеров писал. Даже если я вам скину партномер, что это изменит? Принадлежность разработки, можно посмотреть по стоимости ЗИП-а, у Epson на этот принтер все в 2 раза дешевле, по аналогии HP/Canon.
Покупать HP LaserJet Enterprise 500 MFP M525dn маразм, так как это Canon LBP 6750/6780. На Canon оригинальный зип в два раза дешевле стоит, чем у HP, так как HP тупо покупает у Canon и продает в два раза дороже. Вот и весь бизнес у HP.
Самое интересное сейчас МФУ А4 формата это Canon iR 1435/1435i/1435iF, картридж гигантский, заправлять можно оригиналом 3764B002, тонер не чипованный.
То, что у Canon аппараты дешевле это факт, но вот софт у Canon откровенное “Г”. У аппаратов Canon нет такого понятия как процент оставшегося тонера. У него есть два статуса “все хорошо” и “замените картридж”. Для аппаратов в корпоративном секторе это просто неприемлемо. Что касается МФУ Canon iR 1435, то Вы забыли упомянуть, что тубы у них чипованные и чипы там стоят такие же как в HP M252 и первая же заправка лишает аппарат гарантии. К тому же нет данных, аппарат все таки блокируется после определенного количества страниц или все ограничивается надоедливым замечанием об использовании неоригинальных расходных материалов.
1) Где вы у 9436B002 увидели чип.
2) Любая заправка лишает гарантии, зачем вы это написали? Если в HP сыпать тонер от KM то с гарантией все ок? Так что ли? =)))
3) возможность посмотреть информацию об оставшемся тонере есть: OK, Низкий (8%) и Нет. Что еще нужно?
Все остальное верно только для вашего HP M252.
В любом принтере/мфу софт на любителя, кому-то нравится HP, кому то Kyocera, кого-то тошнит от KDPL у всех свои предпочтения.
По Вашему статусы “ОК” / “мало тонера” / “замените тонер” – информативно? Вот теперь представьте, что готовите срочный отчет и Вам необходимо распечатать несколько тысяч страниц. В статусе стоит “ОК”, а по факту в тубе всего 11% тонера в остатке, конечно Вам не хватить этого ресурса и отчет не распечатается. Именно поэтому я писал, что в корпоративном сегменте, это неприемлемо.
Если Вы считаете, что в Canon нет чипа, то скажите мне что же изображено на фотографии?
Думаю, что да, информации о 8% достаточно. Нормальные организации держат некоторый запас тонера в офисе, хотя бы еще одну тубу, когда вставляют последнюю, заказывают еще 1-5 шт. – и это нормально, так и должно быть, а у совсем грамотных – есть еще и запасной драм с печкой. Зная, что вполне может возникнуть потребность много печатать и не иметь запаса по расходным материалам – глупо, а у тех у кого эта потребность возникла разово, не поможет не 11%, не 15%, не 17% – все равно побегут срочно искать.
Я не знаю, что это за туба на фотографии – у С-EXV 50 чипа нет.
Поискал фотографии — да, что-то есть, не знаю чип это или нет. У меня знакомый человек у которого этот аппарат стоит — сказал, что чипа нет.
Знакомому, рекомендую быть внимательней. И пусть он объяснит Вам, почему при заправке картриджа выскакивает вот такое сообщение “Невозможно правильно определить информацию об уровне тонера. Возможно, отсутствует картридж или вставлен картридж, произведенный не Canon или имеющий неверный номер. Продолжить: Нажмите OK Отмена: Нажмите кнопку останова”
Что касается запаса расходных материалов, то не забывайте, что в России несколько другой менталитет и все экономят каждую копейку. Аппарат изначально сильно бюджетный, и никто под него гору расходных материалов держать не будет.
Что касается фотки, то это C-EXV50, учитесь пока Вам дают бесплатную и главное “ДОСТОВЕРНУЮ” информацию.
Ну так это и HP вашего касается, нет? Ни кто под него запас держать не будет и то, что вы тут про отчет пишите верно для любого аппарата.
3610/3615 – не является разработкой Xerox, сотрите эту информацию и не вводите людей в заблуждение. Учитесь пока вам дают бесплатную и главное «ДОСТОВЕРНУЮ» информацию.
Я выше писал Вам, чтобы вы при утверждении, подкрепляли свою информацию доказательствами. Да и с каких пор Epson стал разрабатывать лазерники? Мне казалось их попытки разрабатывать технику закончились на аппарате Epson c1100.
Будте так любезны подтвердите свою информацию. 3610/3615 является раразобткой Xerox, а потом прочсите этого от других. Я вам все объяснил.
НорУдобный тут у вас коментарии =))))))ма
Canon iR 1435/1435i/1435iF печка тоже стоит столько что вместо замены печки выгоднее купить новый аппарат
Поискал фотографии – да, что-то есть, не знаю чип это или нет. У меня знакомый человек у которого этот аппарат стоит – сказал, что чипа нет.
Ну вот Вам на затравку. Ролики захвата и отделения используются те же что и в аппаратах Xerox 6600/6180/6280. Конструкция лотка классическая Xerox. Веб панель используется классическая Xerox. Общие инженерные решения использованные в аппарате использованы от цветных аппаратов Xerox. Тонер и девелопер используются от цветников Xerox. Чипы тоже использованы от цветников Xerox.
Вот Вам мои доводы, а теперь жду Ваших доводов. На платах нет ни слова про Epson, все партномера родные Xerox.
Источник
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |