CathyO-Xerox
Community Manager
- Mark as New
- Bookmark
- Subscribe
- Subscribe to RSS Feed
- Permalink
- Report Inappropriate Content
07-23-2021
12:34 PM
Hello Dee,
These are not the same devices, but here are the steps to unlock the scanner on the 3645. Have a look to see if you have a scanner lock ….
Thanks,
CathyO-Xerox
Community Manager
Be sure to click
Kudos for those who have helped you.
Select Accept as Solution for posts that have helped to solve your issue(s)!
1
Kudo
Reply
Dee fisher
New Member
- Mark as New
- Bookmark
- Subscribe
- Subscribe to RSS Feed
- Permalink
- Report Inappropriate Content
07-21-2021
08:30 AM
14-100 CCD lock
Product Name: WorkCentre 3335/3345
Operating System: Not Applicable
On my workcenter 3345 i cannot scan anything. have a massage ‘ unlock scanner’.
The problem is that i cannot locate ‘lock switch’ as the printer is showing on the screen. below document feeder.
I switch off and on workcenter multiple times. No results
Please advice how to unlock scanner’
Regards
0
Kudos
Reply
Просмотр сообщений об ошибках и уведомлений на панели
управления
При возникновении ошибки на панели управления отображается сообщение с
информацией о проблеме. Сообщения об ошибке уведомляют пользователя о
состояниях принтера, которые не допускают печать или приводят к ухудшению
показателей печати. Если происходит более одной ошибки, на панели управления
отображается только одно сообщение об ошибке.
Просмотр списка текущих ошибок на панели управления:
1. Нажмите кнопку Статус аппарата, затем нажмите вкладку Активные сообщения.
2. Выберите меню Неисправности и предупреждения, затем выберите нужный
пункт.
• Неисправности: в этом меню показаны сообщения об ошибках, которые
негативно сказываются на работе принтера, а также соответствующие коды
ошибок.
• Предупреждения: в этом меню показаны уведомления, касающиеся текущего
состояния работ, а также соответствующие коды уведомлений.
Просмотр статуса работы на панели управления
Просмотр текущих или сохраненных работ на панели управления:
1. На панели управления принтера нажмите кнопку Статус работы.
2. Чтобы просмотреть список выполняемых работ нажмите Выполняемые работы.
3. Чтобы просмотреть список личных и защищенных работ нажмите Личные и
защищ. работы.
4. Чтобы просмотреть список завершенных работ нажмите Выполнен. работы.
Использование интегрированных программных средств для
устранения неисправностей
В данный принтер встроен комплект отчетов, которые можно распечатать. Два
таких отчета — демонстрационная страница и отчет о сообщениях об ошибках —
могут помочь в устранении некоторых проблем. Изображение на распечатанной
демонстрационной странице показывает текущие возможности печати принтера.
Отчет о сообщениях об ошибках содержит информацию о последних ошибках
принтера.
Многофункциональный принтер Xerox
®
WorkCentre
®
3335/3345
10-40
Руководство пользователя
Устранение проблем
Просмотр сообщений об ошибках и уведомлений на панели
управления
При возникновении ошибки на панели управления отображается сообщение с
информацией о проблеме. Сообщения об ошибке уведомляют пользователя о
состояниях принтера, которые не допускают печать или приводят к ухудшению
показателей печати. Если происходит более одной ошибки, на панели управления
отображается только одно сообщение об ошибке.
Просмотр списка текущих ошибок на панели управления:
1. Нажмите кнопку Статус аппарата, затем нажмите вкладку Активные сообщения.
2. Выберите меню Неисправности и предупреждения, затем выберите нужный
пункт.
• Неисправности: в этом меню показаны сообщения об ошибках, которые
негативно сказываются на работе принтера, а также соответствующие коды
ошибок.
• Предупреждения: в этом меню показаны уведомления, касающиеся текущего
состояния работ, а также соответствующие коды уведомлений.
Просмотр статуса работы на панели управления
Просмотр текущих или сохраненных работ на панели управления:
1. На панели управления принтера нажмите кнопку Статус работы.
2. Чтобы просмотреть список выполняемых работ нажмите Выполняемые работы.
3. Чтобы просмотреть список личных и защищенных работ нажмите Личные и
защищ. работы.
4. Чтобы просмотреть список завершенных работ нажмите Выполнен. работы.
Использование интегрированных программных средств для
устранения неисправностей
В данный принтер встроен комплект отчетов, которые можно распечатать. Два
таких отчета — демонстрационная страница и отчет о сообщениях об ошибках —
могут помочь в устранении некоторых проблем. Изображение на распечатанной
демонстрационной странице показывает текущие возможности печати принтера.
Отчет о сообщениях об ошибках содержит информацию о последних ошибках
принтера.
Многофункциональный принтер Xerox
®
WorkCentre
®
3335/3345
10-40
Руководство пользователя
Устранение проблем
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
- Главная
- Наш блог
- Сервисные мануалы
- Коды сброса ошибок копиров, принтеров и МФУ Xerox
>
>
>
В данной таблице предоставлены коды сброса ошибок популярных моделей аппаратов разных производителей. В левой колонке указана модель аппарата, в правой — метод сброса. Для большинства моделей данной фирмы вход в сервисный режим одинаков — удерживая «0» включить агрегат.
Другие способы входа в сервисный режим
Xerox 5845, 5855 | Либо включить аппарат с одновременно нажатыми кнопками [Прерывание] и [2] либо на включенном аппарате нажать и удерживать эти кнопки более 2 сек. Если аппарат неисправен — вход осуществляется кнопками [Прерывание] и [5], с ограничением функций (последовательно появляющиеся сообщения о неисправностях сбрасываются двойным нажатием клавиши [Стоп]). Далее аппарат запрашивает четырёхзначный код доступа: это либо 8765 (по умолчанию), либо последние четыре цифры счётчика копий в обратном порядке (если счётчик копий показывает 01234567 — код входа 7654). |
Xerox N17 24/32/40 3225/4025 |
Есть 3 диагностических режима: 1 — проверяются выключатели, датчики и выводятся параметры фьюзера; вход: (2+6), после «IOT?» нажать «7»; 2 — печатается тест-лист «сетка» в симплексе или дуплексе; вход: (2+6), после «IOT?» нажать «4»; 3 — меняются параметры и настройки принтера (NVRAM); вход: (2+6), после «IOT?» нажать (4+7), «7» сразу же отпустить; «4» держать до появления «3» на дисплее, затем отпустить. |
XD102…155 XE60…84 XC800…1255 |
stop – auto – stop – auto иногда записывают как C – Density select – C – Density select (что то же самое) |
WC PE 16(e) | набираем на клавиатуре [menu] — [#] — [1934] — [menu]; после входа в сервисное меню появится надпись «TECH» |
Для выхода из режима дважды нажимаем кнопку «Сброс» или выключаем и снова включаем аппарат.
Возможные проблемы
Xerox 5201/5203/5305/5306 XC351/355/356 | Обнуление счетчика фоторецептора. Признак — моргают все лампы, в готовность не выходит.
|
Xerox ХC520/540/560/580 | Сброс ошибки Н3/Н4.
|
Xerox N17, N2125 24/32/40 3225/4025 N2025/2825 Phaser 5400 |
Эти модели имеют счетчик фьюзера. По его окончании аппарат просит заменить набор регламентных работ или «Maintenance Kit». Этот счетчик тоже можно сбросить, если печка в порядке: (2+6), вкл. питание, дождаться «IOT?», не позднее 5 сек. после появления «IOT?» нажать (0+5) и держать до появления сообщения о сбросе «Reset Complete. Please Reboot». Выключите и включите принтер. Рекомендация: все же лучше не просто сбрасывать счетчик, а устанавливать набор, в который входят фьюзер в сборе, ролик переноса, ролики подачи (6 или 15), протирочная салфетка |
WC РE16(e)
Samsung SCX 4016/4116/4216(F) |
Сброс сообщения «Нет тонера» после заправки — есть два варианта: 1. Поставить в паз на передней части картриджа предохранитель на 1/16А (0.0625А), при первом же включении аппарат пережгёт предохранитель и сообщение сбросится. Известны случаи, что работало и с предохранителем до 0.5А; но если МФУ предохранитель не сможет сжечь, будет ошибка CRU FUSE ERROR, которая уходит после установки более слабого предохранителя. 2. Через сервисное меню: для входа в сервисное меню 4216/PE16 набираем на клавиатуре : [menu] — [#] — 1934 — [menu], (для 4016/4116 — [menu] — [upper level] — [Стрелка влево] — [Стрелка вправо] — [upper level] — [enter]). После входа в сервисное меню появится надпись TECH; с помощью клавиш [Стрелка влево] — [Стрелка вправо] находим запись «New cartridge», выбираем «Yes». Для выхода из сервисного меню просто выключаем и включаем МФУ (или для 4216/PE16 набираем на клавиатуре [menu] — [#] — 1934). |
Xerox 4030 | Процедура одинакова для обоих картриджей: удерживая кнопку сброса, находящуюся рядом со шнуром питания; включите принтер. |
Xerox 5017/5316/5317 | Сброс барабана (ошибка J7): на платке с EPROM запаиваем F2, а вместо F1 включаем тестер в режиме измерения тока на пределе 3 mA с защитой. Делаем 101 копию, и – привет! |
DC 212/214 | Сброс ошибки U4. Войдите в диагностический режим и подождите 30 сек, пока аппарат завершит инициализацию. Введите диагностический код [401] и нажмите кнопку «Старт». Выйдите из диагностики, выключите аппарат. Подождите 10 сек, включите аппарат. Подождите 30 сек. Если код U4 появился снова, повторите процедуру сброса. Если после 3-х процедур код появляется вновь, но Вы уверены в работоспособности фьюзера — замените главную плату. |
WC Pro 320 | Сброс кода U4 (печная ошибка) – код 10-1, введите 0 и нажмите кнопку [Старт] |
WC Pro 610 | Тонер: включите аппарат, откройте крышку; нажмите [MENU], [6], [3], [CLEAR], [ENTER] Барабан: включите аппарат, откройте крышку; нажмите [MENU], [6], [4], [CLEAR], [ENTER] |
XD155df | после сброса счётчика 24-7 в 26-38 пропиши 1 – больше считать не будет. |
XE 60/80 | Сброс OPC Cartridge: при включенном питании откройте переднюю крышку; удерживая кнопку [Copy Contrast], закройте крышку и продолжайте держать кнопку 3 секунды. |
Xerox 5845 | При включении требует ввести пользовательский код или кликнуть администратора. Надо войти в «АДМИНИСТРАТОР» (код 11111), затем ввести новый счет; или заблокировать аудитрон. |
НИКОГДА не используйте никаких других диагностических кодов и процедур, потому что это может привести к непредсказуемым последствиям.
Имейте в виду, что сброс ошибки не гарантирует вас от всех остальных бед, поэтому при первой же возможности завезите копировальный аппарат в сервисную фирму, чтобы там удалили отработку, произвели необходимую чистку и регулировки.
Источник: www.startcopy.ru
Для заказа фикс-прошивки на WorkCentre 3335/3345 нужны серийный номер (Machine Serial Number), текущая версия прошивки (System Software Version) и CRUM-номер тонер-картриджа (не от принт-картриджа!).
Как узнать серийный номер
Можно скопировать из программы UDV, либо из конфигурационного отчёта .
Как узнать версию прошивки
Нужно распечатать конфигурационный отчёт (Configuration Report), текущая версия прошивки в строке System Software Version.
- Включите МФУ, загрузите бумагу.
- На панели с кнопками нажмите «Справка» (со знаком вопроса, выше кнопки «3»)
- Выберите «Отчёт о конфигурации»
Версия прошивки будет указана в строке «System Software Version».
Как узнать CRUM-номер чипа
Нужно распечатать отчёт о расходных материалах по инструкции выше, но вместо конфигурации выбирайте расходные материалы.
Другие способы печати отчётов
Через сервисное меню (diagnostics mode):
- Находясь в главном меню («основные режимы») нажмите кнопку «Вход в систему» (иконка ключа, выше кнопки «1»), удерживая её нажмите кнопку решётки, на дисплее появится запрос пароля.
- Введите пароль (по умолчанию 1934) и нажмите на дисплее «Start».
- Нажмите сенсорную кнопку «Service Information», в самом низу будут пункты «Configuration Sheet» и «Supplies Report», выберите нужный и нажмите «Print».
Для заказа прошивки нужно сообщить CRUM-номер тонер-картриджа, но не принт-картриджа (фотобарабан)!