Xerox 3225 ошибка 09 400

Перейти к контенту

  • Печать

Страницы: [1]   Вниз

Тема: xerox phaser 3052  (Прочитано 6046 раз)

Добрый день. Проблема следующая. Xerox phaser3052 ошибка 09-400. Принтер перепрошит. ЧИП заклеен. Ранее все было хорошо, принтер печатал без проблем. В чем может быть проблема?


Записан


Заклейте чип на драм-картридже.


Записан

Купить прошивку на Xerox B205, B210, B215; Samsung M2020, HP 135a, HP 107r, 150a, 150nw и другие: You are not allowed to view links.
Register or Login


Спасибо. Действительно наклейка на «драме» отклеилась.


Записан



  • Печать

Страницы: [1]   Вверх

09-300-00 The drum cartridge is near end of life.

BSD-Reference:

WD 6

Initial Actions

Check Drum Cartridge life count. Replace if at or near end of life.

Reseat the Drum Cartridge.

Procedure

Switch off the electricity to the machine. Disconnect the power cord from the customer

supply while performing tasks that do not need electricity. Electricity can cause death or

injury. Moving parts can cause injury.

Check the Drum Cartridge life counter. Life count is at or near end of life.

Y

N

Cycle system power. The error message is displayed.

Y

N

Reassemble and perform

SCP 6

Replace the Drum Cartridge. The error message is displayed.

Y

N

Reassemble and perform

SCP 6

Remove the Right Cover

(REP

28.2) and reseat CN16 on the MCU Board. The

message is displayed.

Y

N

Reassemble and perform

SCP 6

Replace the MCU Board,

REP

9.8.

Replace the Drum Cartridge.

Status Indicator RAPS

09-300-00, 09-400-00

WARNING

Final Actions.

Final Actions.

Final Actions.

09-400-00 Replace Drum Cartridge RAP

09-400-00 The Drum Cartridge has reached end of life.

BSD-Reference:

WD 6

Initial Actions

Check Drum Cartridge life count. Replace if at or near end of life.

Procedure

Switch off the electricity to the machine. Disconnect the power cord from the customer

supply while performing tasks that do not need electricity. Electricity can cause death or

injury. Moving parts can cause injury.

Check the Drum Cartridge life counter. Life count is at end of life.

Y

N

Cycle system power. The error message is displayed.

Y

N

Reassemble and perform

Replace the Drum Cartridge. The error message is displayed.

Y

N

Reassemble and perform

Remove the Right Cover

message is displayed.

error

Y

N

Reassemble and perform

Replace the MCU Board,

Replace the Drum Cartridge.

5/2011

2-50

WARNING

SCP 6

Final Actions.

SCP 6

Final Actions.

(REP

28.2) and reseat CN16 on the MCU Board. The

SCP 6

Final Actions.

REP

9.8.

Revision — Xerox Internal Use Only

Phaser 4600/4620 Printer Service Manual

error

Ремонт Xerox Phaser 3052

Ремонт Xerox Phaser 3052

В сервисном центре Комплэйс можно осуществить ремонт Xerox Phaser 3052. Для этого нужно привезти принтер в мастерскую Комплэйс. На выезде не работаем. Срок ремонта один-два дня. Гарантия на выполненную работу 2 месяца.

Принтер Xerox 3052 имеет отдельный тонер картридж с чипом и  и отдельный барабан со своим чипом.  Ресурс тонер картриджа 3000 страниц. Ресурс фотобарабана 10000 страниц.

Новый оригинальный картридж стоит более 3300 рублей, фотобарабан около 5000 рублей. Покупать каждый раз новый картридж, но и барабан накладно. Чтобы избавиться от этого геморроя, можно прошить принтер специальной прошивкой. И забыть про чипы на тонер картридж и фотобарабан. Производить замену барабана только при надобности, когда ухудшается качество печати.

При возникновении ошибки 09-400 лучше всего сделать новую прошивку. Она избавит вас от этой ошибки навсегда. Кстати, заодно вы сможете заправлять Xerox 3052 без замены чипа.

Прошить принтер Xerox 3052 стоит 1500 рублей. Действует эта прошивка бессрочно, чипы на картридже и фотобарабане нужно после прошивки заклеить или убрать.

Заправка картриджа Xerox 3052 стоит 600 рублей, замена фотовала в барабане стоит 1200 рублей.

Ремонт подачи бумаги стоит от 1500 до 3000 рублей.

Ремонт узла термозакрепления (печки) до 3000 руб.

Читать про ремонт принтеров и МФУ Xerox.

  • Печать

Страницы: [1]   Вниз

Тема: xerox phaser 3052  (Прочитано 6801 раз)

Добрый день. Проблема следующая. Xerox phaser3052 ошибка 09-400. Принтер перепрошит. ЧИП заклеен. Ранее все было хорошо, принтер печатал без проблем. В чем может быть проблема?


Записан


Заклейте чип на драм-картридже.


Записан

Купить прошивку на Xerox B205, B210, B215; Samsung M2020, HP 135a, HP 107r, 150a, 150nw и другие: You are not allowed to view links.
Register or Login


Спасибо. Действительно наклейка на «драме» отклеилась.


Записан



  • Печать

Страницы: [1]   Вверх

– Compatible Printer model: Xerox WorkCentre 3225
– Xerox WorkCentre 3225 Error Codes with quick guides:

  • Code: 01-100
  • Description: Front Cover Open Fault The front cover is open or the cover open switch is defective.
  • Troubleshooting Guides: Check the Actuator on the Front Cover Open Switch. The Actuator moves freely. Y↓N→Replace the Front Cover Open Switch Actuator. (PL-XX) Check the Front Cover Open Switch. The switch is OK. Y↓N→Replace the Front Cover Open Switch. (PL-XX) Check the connection between the Main PWB and the HVPS (BSD 3.1A). The connection is secure. Y↓N→Secure the connection between the Main PWB and HVPS. Replace the HVPS PWB (PL-XX).
  • Code: 03-410
  • Description: Paper Mismatch at Tray 1 The size setting for the Paper Tray does not match the paper size loaded in the tray.
  • Troubleshooting Guides: • Check the media size settings for the tray from the Control Panel. • Adjust the Paper Tray Guides to match the size of the paper that is loaded into the tray. • Place the correct size paper into the tray for the tray size setting.
    Remove the tray and inspect the Paper Size Switch for wear or contamination. The switch is operational. Y↓N→Replace the Paper Size Switch (PL-XX). • Replace the Paper Tray (PL-XX) • Replace the Main PWB, (PL-XX)
  • Code: 03-450
  • Description: Paper Mismatch at Manual Feed Slot The size setting for the Manual Feed Slot does not match the paper size loaded
  • Troubleshooting Guides: • Check the media size settings for the tray from the Control Panel. • Adjust the Paper Tray Guides to match the size of the paper that is loaded into the tray. • Place the correct size paper into the tray for the tray size setting.
    Inspect the Paper Size Switch for wear or contamination. The switch is operational. Y↓N→Replace the Paper Size Switch (PL-XX). • Replace the Paper Tray (PL-XX). • Replace the Main PWB, (PL-XX).
  • Code: 03-900
  • Description: Main PWB Motor Control Chip Fault The Motor Control Chip on the Main PWB is not functioning normally.
  • Troubleshooting Guides: 1. Switch Off the power then switch On the power. 2. If problem continues, replace the Main PWB, (PL-XX).
  • Code: 04-500
  • Description: Main Drive (BLDC) Motor Start Fault The Main Drive (BLDC) Motor did not start within the specified time after the ready signal was sent.
  • Troubleshooting Guides: Enter Diagnostic Mode. Press the <Menu> button, the <#> button, then using the keypad select: [1934, Diagnostics, Machine Test, EDC Mode, DC330 Component Control, 100 Motor] to start the motor. The motor rotates. Y↓N→Remove the Right Cover and check the motor connector on the Main PWB. The connector on the Main PWB is connected correctly. Y↓N→Reconnect the motor connector. Remove the Duplex paper Guide. Check the motor connector. The connector is OK. Y↓N→Reconnect the connector The Imaging Unit Drive coupler may have overloaded. Remove the Print Cartridge and rotate the Imaging Unit coupler. The Imaging Unit coupler rotates freely. Y↓N→Replace the Imaging Unit. The Main Drive Motor or the Main PWB is defective. Perform the following: • Replace the Main Drive Motor PL 4.1. If problem persists, replace the Main PWB, PL 1.1.
  • Code: 05-100, 05-900
  • Description: Paper Jam in Document Feeder Fault The machine has detected a paper jam in the Document Feeder.
  • Troubleshooting Guides: Inspect the Paper Path Sensor for damage or contamination. Remove any debris from the sensor. Enter Diagnostic Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102 Sensor, Temp A] to test the Registration Sensor. The sensor is OK. Y↓N→Replace the Paper Path Sensor PL 7.1. Check that the Feed Motor is operating correctly. Select: [Machine Test, EDC Mode, DC330 Component Control, 100 Motor, Feed Motor Slow] The Feed Motor is OK. Y↓N→Check the connection from the Feed Motor to the Main PWB is securely seated. The motor is OK. Y↓N→• Replace the Feed Motor. [PL-XX] • Replace the Document Feed Assembly [PL-XX] Go to SCP 04 Final Actions. Check the paper path drives and clear any jammed sheets from the paper path. If problem persists, replace the Main PWB PL 1.1.
  • Code: 05-500
  • Description: Document Feeder Cover Open Fault The Document Feeder or Document Feeder Top Cover is not securely latched.
  • Troubleshooting Guides: • Close the Document Feeder unit. • Close the Document Feeder top cover.
    Remove the top cover and check the connection to the PWB sensor switch. The connection is secure. Y↓N→Secure the connection. Replace the sensor? (switch?)
  • Code: 06-100, 06-200
  • Description: Laser Module (LSU) Motor Fault The machine has detected that the Laser Module Drive Motor is not working correctly.
  • Troubleshooting Guides: Enter Diagnostic Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 110 LSU, LSU Mot1 Run] to test the LSU motor. The motor runs. Y↓N→Check the Main Wire Harness and connectors on the Laser Module. The connections are secure. Y↓N→Disconnect and securely reconnect the harness. Check the harness for a short circuit or open circuit. The harness is OK. Y↓N→Replace the harness. Replace the Laser Module (PL-XX) Go to SCP 04 Final Actions.
  • Code: 07-110
  • Description: Paper Tray 1 Empty Fault The Tray Empty Sensor failed to detect paper in the tray.
  • Troubleshooting Guides: Check the Tray Empty Sensor actuator. The actuator moves freely is undamaged. Y↓N→Replace the Empty Sensor actuator (PL-XX). Enter Diagnostic Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102 Sensor, Tray 1 Empty] to actuate and de actuate the Tray 1 Empty Sensor. The sensor signal changes. Y↓N→Replace the Tray Empty Sensor (PL-XX). If the problem is intermittent, check the circuit of the Tray Empty Sensor. (BSD-tbd)
  • Code: 07-130
  • Description: Paper Jam in Tray 1 Fault A paper jam has occurred in Tray 1.
  • Troubleshooting Guides: Remove Tray 1 and ensure that guides are set correctly. The paper is loaded correctly in the tray. Y↓N→Align the paper in Tray 1 then reinsert the tray. Check the position of the jammed sheet. The lead edge reached the Retard Roll. (Figure 1.) Y↓N→Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102-Sensor, Feed Sens] to block and clear the Feed Sensor. The sensor is OK. Y↓N→Replace the Feed Sensor (PL-XX). In Diagnostics Mode, go to [101-Clutch, Tray 1 Pick up] to energize the clutch. The clutch engages. Y↓N→Replace the Tray 1 Pick up (Feed) Clutch (PL-XX). Perform SCP Final Actions. Remove any jammed paper. Check the following for wear or damage and replace as required: • Retard Roller (PL-XX) • Pick up (Feed) and Forward Roll Assembly (PL-XX) • Elevator Plate (PL-XX) • Elevator Plate Springs (PL-XX)
  • Code: 07-500
  • Description: Manual Feed Slot Paper Empty Fault The Manual Feed Slot Empty Sensor failed to detect paper in the Manual Feed Slot.
  • Troubleshooting Guides: Check the Manual Feed Slot Empty Sensor actuator. The actuator moves freely and is undamaged. Y↓N→Replace the Empty Sensor Actuator (PL-XX). Block and clear the Manual Feed Slot Empty Sensor. The sensor signal changes. Y↓N→Replace the Tray Empty Sensor (PL-XX). Check the circuit of the Tray Empty Sensor.
  • Code: 07-530
  • Description: Paper Feed Fault – Manual Feed Slot The lead edge was not detected by the Paper Feed Sensor.
  • Troubleshooting Guides: Check the position of the jammed sheet. The lead edge reached the Retard Roll. Y↓N→Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102-Sensor, Feed Sens] to block and clear the Feed Sensor. The sensor is OK. Y↓N→Replace the Feed Sensor (PL-XX). In Diagnostics Mode, select: [101-Clutch, Registration or PU?] to engage the drive to pick up paper from tray 1. The clutch engages. Y↓N→Replace the Tray 1 Pick up (Feed) Clutch (PL-XX). Perform SCP Final Actions. Check the Paper Feed actuator. The actuator moves freely is undamaged. Y↓N→Replace the Paper Feed actuator. Inspect the Paper Feed Sensor for damage. The sensor is OK. Y↓N→Replace the Paper Feed Sensor. Check the circuit of the Paper Feed Sensor.

Xerox WorkCentre 3225 error and solving error codes

Solve Xerox WorkCentre 3225 Error codes

  • Code: 08-100
  • Description: Paper Feed Fault – Tray 1 The lead edge was not detected by the Paper Feed Sensor
  • Troubleshooting Guides: Check the Tray 1 Pick up Sensor Actuator. The Actuator moves freely. Y↓N→Replace the Tray 1 Pick up Sensor Actuator (PL-XX). Check the position of the jammed sheet. The lead edge reached the Retard Roll. (Figure 1.) Y↓N→Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 101-Clutch, Tray 1 Pick up] to engage the drive to pick up paper from tray 1 The clutch engages. Y↓N→Replace the Tray 1 Pick up (Feed) Clutch (PL-XX). Check the Paper Feed Actuator. The actuator moves freely. Y↓N→Replace the Paper Feed Actuator. In Diagnostics Mode. Select: [102-Sensor, Feed Sens] to block and clear the Paper Feed Sensor. The signal changes. Y↓N→Replace the Paper Feed Sensor (PL-XX). Perform SCP Final Actions. Check the circuit of the Paper Feed Sensor. (BSD-tbd)
  • Code: 08-500
  • Description: Paper Jam in Exit Area Fault The machine has detected a paper jam in the Exit Area.
  • Troubleshooting Guides: Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102-Sensor, Feed Sens] to test the Exit Sensor. The Exit Sensor is OK. Y↓N→Replace the Exit Sensor (PL-XX). In Diagnostics Mode, go to [102-Sensor, Registration] to activate and deactivate the Registration Sensor. The signal changes. Y↓N→Replace the Registration sensor. (PL-XX) Inspect the Exit Roller and Drives for wear or damage.. Replace if needed.
  • Code: 08-600
  • Description: Paper Jam in Duplex Area Fault The machine has detected a paper jam in the Duplex Area.
  • Troubleshooting Guides: Check the Exit Sensor Actuator. The actuator moves freely. Y↓N→Replace the Exit Sensor Actuator. Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102-Sensor, Out Bin Exit Sens] to test the Exit Sensor. The sensor is OK. Y↓N→Replace the Exit Sensor. (PL-XX). Check the following parts for wear or damage and replace if needed: • Duplex Paper Guide• Duplex Gate • Duplex Gate Spring • Duplex Gate Mounting • Paper Guide on Rear Cover Make certain that the Duplex Gate is seated correctly and moves freely without binding.
  • Code: 08-700
  • Description: Output Tray Full Fault The Output Tray Full Sensor has detected that the Output Tray is full.
  • Troubleshooting Guides: Enter Diagnostics Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 102-Sensor, Out Bin Full] to test the Out Bin Full Sensor. The signal changes. Y↓N→• Check that the sensor connector is firmly seated. • Replace the Out Bin Full Sensor. (PL-XX) Check actuator for binding. If the problem is intermittent, replace the Out Bin Full Sensor Actuator. (PL-XX)
  • Code: 09-100
  • Description: Print Cartridge Near End of Life Fault The toner cartridge life is less than 10%.
  • Troubleshooting Guides: 1. Press the Information button on the Control Panel, then select the menu items listed below to print the Supplies Information Report. Refer to the WorkCentre 3215/3225 User Guide for detailed instructions on Menu Options using the Control Panel. • WorkCentre 3215: [Info Pages, Supplies Info]. • WorkCentre 3225: [Machine Status, Info Pages, Supplies Info]. 2. Check the remaining life of the Print Cartridge. 3. If the Print Cartridge has reached end of life, switch Off the power and replace the Print Cartridge.
  • Code: 09-300
  • Description: Imaging Unit Near End of Life Fault The toner cartridge life is less than 10%.
  • Troubleshooting Guides: 1. Press the Information button on the Control Panel, then select the menu items listed below to print the Supplies Information Report. Refer to the WorkCentre 3215/3225 User Guide for detailed instructions on Menu Options using the Control Panel. • WorkCentre 3215: [Info Pages, Supplies Info]. • WorkCentre 3225: [Machine Status, Info Pages, Supplies Info]. 2. Check the remaining life of the Imaging Unit. 3. If the Imaging Unit has reached end of life, switch Off the power and replace the Imaging Unit.
  • Code: 09-350, 09-400
  • Description: Print Cartridge End of Life Fault The Print Cartridge has reached end of life.
  • Troubleshooting Guides: 1. Press the Information button on the Control Panel, then select the menu items listed below to print the Supplies Information Report. Refer to the WorkCentre 3215/3225 User Guide for detailed instructions on Menu Options using the Control Panel. • WorkCentre 3215: [Info Pages, Supplies Info]. • WorkCentre 3225: [Machine Status, Info Pages, Supplies Info]. 2. Check the remaining life of the Print Cartridge. 3. If the Print Cartridge is at end of life, switch Off the power and replace the Print Cartridge.
  • Code: 09-550
  • Description: Print Cartridge Undetected Fault The Print cartridge has not been installed or machine software is unable to detect the Print Cartridge.
  • Troubleshooting Guides: Ensure that the Print Cartridge has been installed and the cover is fully closed and latched.
    1. Switch Off the power then switch On the power. 2. Remove the Print cartridge. Rotate the cartridge five to six completions to distribute the toner evenly. 3. Check the CRUM contact area for contamination and clean if necessary. 4. Reinstall the Print Cartridge. 5. If the problem continues, install a new Print Cartridge.
  • Code: 09-800
  • Description: Incompatible Print Cartridge Fault The Print Cartridge is not compatible with the printer.
  • Troubleshooting Guides: 1. Press the Information button on the Control Panel, then select the menu items listed below to print the Supplies Information Report. • WorkCentre 3215: [Info Pages, Supplies Info]. • WorkCentre 3225: [Machine Status, Info Pages, Supplies Info]. 2. Check the toner cartridge information. Replace the Print Cartridge if is not a genuine Xerox cartridge.
  • Code: 09-900
  • Description: Imaging Unit Undetected Fault The Imaging Unit has not been installed or machine software is unable to detect the Imaging Unit. Incompatible Imaging Unit Fault The Imaging Unit (Drum Cartridge) is not compatible with the printer.
  • Troubleshooting Guides: Check the Imaging Unit (Drum Cartridge) CRUM connection. 1. Press the Information button on the Control Panel, then select the menu items listed below to print the Supplies Information Report. • WorkCentre 3215: [Info Pages, Supplies Info]. • WorkCentre 3225: [Machine Status, Info Pages, Supplies Info]. 2. Check the Imaging Unit information. Replace the Imaging Unit if is not a genuine Xerox cartridge
  • Code: 10-100
  • Description: Fuser Temperature (Open) Fault The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ± 5°C.)
  • Troubleshooting Guides: Power Off the machine and check that the Fuser connection is fully seated. The Fuser connections are OK. Y↓N→Firmly reconnect the Fuser assembly. Switch the power ON. Check for +3.3 VDC to the Thermistor at P/J on Main PWB. The voltage is OK. Y↓N→• Check the wire harness for open or short circuits. • Replace the Main PWB, (PL-XX) Check the voltage to the Over Heat Thermostat. The voltage is OK. Y↓N→• Check for AC line voltage to the LVPS PWB. • Check the wire harness for open or short circuits. • Replace the LVPS PWB (PL-XX) if needed. Check the Heat Lamp for an open circuit. (BSD-XX) Repair or replace the Fuser Assembly as required. (PL-XX)
  • Code: 10-200, 10-300
  • Description: Fuser Under/ Over Temperature Fault The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ± 5°C.)
  • Troubleshooting Guides: Enter Diagnostic Mode. Select: [Machine Test, EDC Mode, DC330 Component Control, 109 Fuser Heat, Temp A] to obtain a temperature reading from the Fuser. The Fuser temperature is within normal operating range. Y↓N→Replace the Fuser Assembly (PL-XX) If problem is intermittent, check the circuit of the Fuser Assembly.
  • Code: 14-100
  • Description: Document Scanner Assembly Locked Fault The Document Scanner Assembly does not move.
  • Troubleshooting Guides: Check the Scanner Cable to make sure it is securely connected. The scanner cable is connected. Y↓N→Reconnect the Scanner Cable. Check the Scanner Drive Motor. The Motor runs. Y↓N→Replace the Scanner Drive Assembly. Replace parts as needed.. If the problem continues, replace the Main PWB (PL-XX).
  • Code: 17-100
  • Description: IP Conflict Error Fault The IP address conflicts with that of another system causing a machine communication error.
  • Troubleshooting Guides: Use Xerox Easy Print Manger to obtain a new IP address. From the menu, select: [Machine Settings, Network Settings, Assign IP address].
  • Code: 17-310
  • Description: Communication Error (Main PWB to Wireless PWB) Fault The machine software has detected a communication error between the Main PWB and the Wireless PWB.
  • Troubleshooting Guides: 1. Ensure that the connectors are fully seated between the Main PWB and the Wireless PWB. 2. If the problem persists, replace parts in the following order: • Flat Cable (PL-XX) • Wireless PWB (PL-XX) • Main PWB (PL-XX)
  • Code: 17-700, 17-710
  • Description: BOOTP Error Fault The machine displays the error message “DHCP, or BOOTP, causing a machine communication error.
  • Troubleshooting Guides: 1. Switch Off the power then switch On the power. 2. Check BOOTP and network configuration.
  • Code: 17-800, 17-810
  • Description: DHCP Error Fault The machine displays the error message “DHCP, or BOOTP, causing a machine communication error.
  • Troubleshooting Guides: 1. Switch Off the power then switch On the power. 2. Check DHCP and network configuration.
  • Code: 17-900
  • Description: 802.1X Network Authentication Error Fault The the 802.1X network authentication failed.
  • Troubleshooting Guides: Ensure that the 802.1X EAP Type, User name, and Password, for the Machine, Authentication Switch and Authentication Server match
  • Code: 17-910
  • Description: Firmware Upgrade Fault The firmware upgrade aborted due to an invalid file.
  • Troubleshooting Guides: 1. Check the USB connection. 2. Verify that the correct firmware file is being used.
    Cycle the machine power and repeat upgrade procedure GP 6.
  • Code: 20-100
  • Description: Fax Communication Error Fault A communication error occurred during a fax transmission.
  • Troubleshooting Guides: 1. Call the target fax number to confirm a fax response. 2. Check condition of the fax line and connection. 3. Verify that the fax line is an analog phone line. 4. Switch Off the power then switch On the power. 5. Verify that the country setting is correct. 6. Resend the fax job. 7. Check fax communications to a different machine.
    Enter Diagnostic Mode. From the Control panel, select: [Report, Error Info, Print] to print the Error Information Report. The target fax is causing the error. Y↓N→Go to Diagnostics, select: [Report, Fax Options] to verify Fax Send settings are at default. Check that the Target Fax configuration is OK. The Target Fax is OK. Y↓N→Reconfigure Target Fax. Reseat the Fax PWB. The fault clears. Y↓N→Replace the Fax PWB. (PL-XX) Check the connection between the P/J on the Fax board (BSD XX) and the Main PWB. The connection is secure. Y↓N→Firmly reconnect the connector. Replace the Main PWB, (PL-XX).
  • Code: 20-120
  • Description: Scanning Error Fault A error such as a paper jam or scanner fault has occurred during a manual-dial fax operation.
  • Troubleshooting Guides: Clear any jammed sheets. Refer to the WorkCentre 3215/3555 User Guide for detailed jam clearance instructions. Check the scanner. Refer to RAP 14-100 for troubleshooting the scanner. Resubmit the job.
  • Code: 20-200
  • Description: Group Not Available Fault User has selected a group location where only a single location number can be used. (I.e.: Adding locations for a multi-dial operation.)
  • Troubleshooting Guides: Resubmit fax using a group location.
  • Code: 20-400, 20-410
  • Description: Line Fault Unable to connect with the remote machine. The fax line is busy or an error has occurred with fax transmission due to a phone line problem
  • Troubleshooting Guides: Resubmit fax job. If problem persists, resubmit after an hour.
  • Code: 20-500
  • Description: Memory Full Fault The memory is full.
  • Troubleshooting Guides: Delete necessary documents, resend job when memory becomes available, or split the transmission into multiple operations.
  • Code: 20-600
  • Description: No Answer Fault The printer unable to connect to remote machine after maximum redial attempts.
  • Troubleshooting Guides: Ensure that remote machine is powered on and reattempt submission.
  • Code: 20-700
  • Description: Number Not Assigned Fault The speed dial location used has no number assigned to it.
  • Troubleshooting Guides: Dial the number manually or assign the number to the speed dial location.
  • Code: 20-900
  • Description: Retry Redial Fault The machine is waiting for the programmed interval to automatically redial.
  • Troubleshooting Guides: Press <START> to immediately redial or <STOP> to cancel the redial operation.



– Get more error code list with quick guide to fix printer product, click here


– About get help with reseting Epson inkpad or others, click here

– Get more information about Epson XP 15000 troubleshooting, click here

Xerox printer reset software introduction:

Notes before resetting Xerox printer:

– Identify accurate version, serial and crum of Xerox printer.
– How to get Xerox printer model info: Click Here
– Before you continue with the reprogramming of the firmware, please make sure that the device is installed on your computer.
It is very important that under no circumstances should you remove the chip from the cartridge while reprogramming the firmware. After you have succesfully reprogrammed the printer, remove the chip from the cartridge and store it somewhere safely (the chip – a key). In all cartridges which you are going to use in the printer, the chip has to be either removed or sealed. If you have accidently inserted a new cartridge without removing the chip, the device will be blocked. In order to unblock it, you can use the stored chip as a key which help you to unblock the printer.
– And make sure that any other devices (except mouse and keyboard), which are connected to your computer via USB or LPT ports are disconnected. It’s preferable that the computer is connected to the “UPS” (uninterruptible power source) device, because if during the reprogramming process the electricity source has any interruptions, then the reprogramming will be carried out with an error, which makes the device unable to work.
– This firmware will be installed directly to your printer. Before opening firmare link make sure that printer is turned on and connected to your computer and printer drivers are installed correctly.
Be aware that with the reprogramming of the firmware the manufacturer’s warranty goes lost!!

How To Run Firmware Fix Xerox printer

1. Connect the printer to the computer and turn it on.
2. Wait until the printer is ready for work.
3. Drag and drop *.hd to usbprns2.exe file.

Run Firmware Fix Xerox B205

4. The reprogramming process starts automatically.
5. Wait until the printer reprograms (10-20 minute) and restarts.
6. After that the reprogramming process is finished, restart the printer.
– Fix Xerox B205 Toner Empty Error, click here

Contact us to get support with Xerox WorkCentre 3225 Error case

Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.

093-400, 093-406 to 093-409, 093-423 to 093-425 Toner Cartridge Near End of Life RAP

093-400 Black toner cartridge is near end of life.
093-406 Black toner cartridge is near end of life.
093-407 Yellow toner cartridge is near end of life.
093-408 Magenta toner cartridge is near end of life.
093-409 Cyan toner cartridge is near end of life.
093-423 Yellow toner cartridge is near end of life.
093-424 Magenta toner cartridge is near end of life.
093-425 Cyan toner cartridge is near end of life.

Procedure

Information only. No service action necessary. Advise the customer that the toner cartridge is
almost empty. Or prepare toner cartridge CRUM (toner chip) listed as below to refill the toner cartridge.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Like this post? Please share to your friends:
  • Xerox 3220 ошибка сканера
  • Xenus 2 белое золото ошибка vital engine
  • Xerox 3220 ошибка открыта крышка
  • Xerox 3100 ошибка флеш flash plug init
  • Xentry ошибка отсутствует право доступа