U029d00 ошибка вольво fh4

          Volvo vehicles, like any other vehicles, also generate many unwarranted error codes. Error codes often occur in heavy duty vehicles due to high torque and high load. The error codes most frequently encountered by users are from from the Adblue system.

         When we say Adblue systems, we often think about system that breaks very easily. These systems are often used in heavy loads and commercial vehicles. Lately, it has begun to be used in passenger cars. these systems are not used in most countries, even if they are mandatory in Europe. Because it is not structured correctly. Even the adblue liquid, that this system uses, is very difficult to find on the market. Like we said, the system is unstable and users are having trouble. It is a very difficult situation when the systems breaks in the middle of road . Repair of the system is very costly and you lose precious time. For this reason, users are often looking for solutions. One of the solution is an Adblue Emulator developed by SAIL TECHNOLOGY. It is a permanent solution and will be there right beside you in every situation. Adblue Emulators, which many users prefer, will not let you down.

So what do these emulators do and what information do they give? Below are the benefits and fault code information of the SAIL Technology Adblue Emulator we have listed for you.

The instructional models are designed for: Volvo B11R (3), Volvo B5LH (3), Volvo B5TL (3), Volvo B8R (3), Volvo FH (4).

Attention: Please visit https://canbusemulator.com for more detailed information about diagnostic trouble codes

DTC DTC

DTC Code Name

Type of malfunction

P001676

Crankshaft Position — Correlation with Camshaft Position

Incorrect installation position

P003A99

Turbocharger / turbocharger supercharging control position «A» has exceeded the training threshold

Parameter limit exceeded

P004513

Open in turbocharger / turbocharger supercharging control circuit «A»

Open circuit

P004519

Open in turbocharger / turbocharger supercharging control circuit «A»

Current in the circuit above the threshold

P004577

Open in turbocharger / turbocharger supercharging control circuit «A»

The required position is unattainable

P004591

Open in turbocharger / turbocharger supercharging control circuit «A»

Parametric

P004592

Open in turbocharger / turbocharger supercharging control circuit «A»

Characteristics or malfunctioning

P00459A

Open in turbocharger / turbocharger supercharging control circuit «A»

Working conditions of a component or system

P006964

Correlation of absolute pressure in the reservoir and barometric pressure

Violation of signal reliability

P006E16

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit below the threshold

P006E17

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit above the threshold

P007011

Outdoor temperature sensor «A»

Short to ground

P007015

Outdoor temperature sensor «A»

Circuit short to battery voltage or break

P008700

The pressure in the fuel distribution pipe / system is too low, row 1

No subtype information

P008800

The pressure in the fuel distribution pipe / system is too high, row 1

No subtype information

P008A00

The pressure in the low-pressure fuel system is too low

No subtype information

P008B00

The pressure in the low-pressure fuel system is too high

No subtype information

P008B97

The pressure in the low-pressure fuel system is too high

The operation of the component or system is difficult or blocked

P009011

Control of fuel pressure regulator 1

Short to ground

P009012

Control of fuel pressure regulator 1

Circuit Short to Battery Voltage

P009013

Control of fuel pressure regulator 1

Open circuit

P009400

A leak in the fuel system — a small leak

No subtype information

P009A00

Air temperature at engine intake — correlation

No subtype information

P009B11

Fuel Pressure Relief Control

Short to ground

P009B12

Fuel Pressure Relief Control

Circuit Short to Battery Voltage

P009B13

Fuel Pressure Relief Control

Open circuit

P009B73

Fuel Pressure Relief Control

The actuator jammed in the closed position

P00AF41

Performance characteristics of the turbocharger / turbocharger supercharger control module «A»

Total checksum error

P00C600

Too low pressure in the fuel distribution pipe — engine crankshaft rotation

No subtype information

P010501

Absolute pressure sensor in the manifold / barometric pressure

General electrical fault

P010512

Absolute pressure sensor in the manifold / barometric pressure

Circuit Short to Battery Voltage

P010513

Absolute pressure sensor in the manifold / barometric pressure

Open circuit

P010562

Absolute pressure sensor in the manifold / barometric pressure

Signal comparison error

P011001

Intake air temperature sensor 1, row 1

General electrical fault

P011011

Intake air temperature sensor 1, row 1

Short to ground

P011013

Intake air temperature sensor 1, row 1

Open circuit

P011501

Engine Coolant Temperature Sensor 1

General electrical fault

P011511

Engine Coolant Temperature Sensor 1

Short to ground

P011513

Engine Coolant Temperature Sensor 1

Open circuit

P01152A

Engine Coolant Temperature Sensor 1

Stuck signal in the range

P012011

Throttle / Pedal Position Sensor «A»

Short to ground

P012012

Throttle / Pedal Position Sensor «A»

Circuit Short to Battery Voltage

P012800

Coolant thermostat (coolant temperature below the thermostat control temperature)

No subtype information

P016800

Fuel temperature in engine too high

No subtype information

P016E00

Control of the fuel pressure in a closed loop at the limit is too high a pressure

No subtype information

P016F00

Controlling the fuel pressure in a closed loop at the limit is too low a pressure

No subtype information

P018501

Fuel temperature sensor «B»

General electrical fault

P018511

Fuel temperature sensor «B»

Short to ground

P018513

Fuel temperature sensor «B»

Open circuit

P018564

Fuel temperature sensor «B»

Violation of signal reliability

P019001

Pressure sensor in the fuel distributor pipe, row 1

General electrical fault

P019011

Pressure sensor in the fuel distributor pipe, row 1

Short to ground

P019013

Pressure sensor in the fuel distributor pipe, row 1

Open circuit

P019062

Pressure sensor in the fuel distributor pipe, row 1

Signal comparison error

P019064

Pressure sensor in the fuel distributor pipe, row 1

Violation of signal reliability

P019511

Engine oil temperature sensor «A»

Short to ground

P019513

Engine oil temperature sensor «A»

Open circuit

P019564

Engine oil temperature sensor «A»

Violation of signal reliability

P01B901

Engine oil temperature sensor «B»

General electrical fault

P01B911

Engine oil temperature sensor «B»

Short to ground

P01B913

Engine oil temperature sensor «B»

Open circuit

P020111

Cylinder 1 nozzle «A»

Short to ground

P020112

Cylinder 1 nozzle «A»

Circuit Short to Battery Voltage

P020113

Cylinder 1 nozzle «A»

Open circuit

P020156

Cylinder 1 nozzle «A»

Invalid / incompatible configuration

P020211

Cylinder 2 injector «A»

Short to ground

P020212

Cylinder 2 injector «A»

Circuit Short to Battery Voltage

P020213

Cylinder 2 injector «A»

Open circuit

P020256

Cylinder 2 injector «A»

Invalid / incompatible configuration

P020311

Cylinder 3 injector «A»

Short to ground

P020312

Cylinder 3 injector «A»

Circuit Short to Battery Voltage

P020313

Cylinder 3 injector «A»

Open circuit

P020356

Cylinder 3 injector «A»

Invalid / incompatible configuration

P020411

Cylinder 4 nozzle «A»

Short to ground

P020412

Cylinder 4 nozzle «A»

Circuit Short to Battery Voltage

P020413

Cylinder 4 nozzle «A»

Open circuit

P020456

Cylinder 4 nozzle «A»

Invalid / incompatible configuration

P020511

Cylinder 5 injector «A»

Short to ground

P020512

Cylinder 5 injector «A»

Circuit Short to Battery Voltage

P020513

Cylinder 5 injector «A»

Open circuit

P020556

Cylinder 5 injector «A»

Invalid / incompatible configuration

P020611

Cylinder 6 nozzle «A»

Short to ground

P020612

Cylinder 6 nozzle «A»

Circuit Short to Battery Voltage

P020613

Cylinder 6 nozzle «A»

Open circuit

P020656

Cylinder 6 nozzle «A»

Invalid / incompatible configuration

P021700

Engine coolant temperature exceeded status

No subtype information

P021800

The condition of the transmission oil temperature rise

No subtype information

P021900

State of excess of engine speed

No subtype information

P023400

Overcharging state of turbocharger / supercharger

No subtype information

P024311

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Short to ground

P024312

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Circuit Short to Battery Voltage

P024313

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Open circuit

P025612

Fuel Injector Diesel Injector

Circuit Short to Battery Voltage

P025614

Fuel Injector Diesel Injector

Short to ground or open

P025692

Fuel Injector Diesel Injector

Characteristics or malfunctioning

P026A00

The efficiency of the charge air cooler is below the threshold

No subtype information

P029800

Excess temperature of engine oil

No subtype information

P029900

Insufficient supercharging of the turbocharger / supercharger

No subtype information

P02CC00

Fuel injector cylinder 1 — determination of the correction at the minimum limit

No subtype information

P02CD00

Fuel injector cylinder 1 — determination of the correction at the maximum limit

No subtype information

P02CE00

Fuel injector cylinder 2 — determination of the correction at the minimum limit

No subtype information

P02CF00

Fuel injector cylinder 2 — determination of the correction at the maximum limit

No subtype information

P02D000

Fuel injector cylinder 3 — determination of the correction at the minimum limit

No subtype information

P02D100

Fuel injector cylinder 3 — determination of the correction at the maximum limit

No subtype information

P02D200

Fuel injector of the cylinder 4 — determination of the correction at the minimum limit

No subtype information

P02D300

Fuel injector cylinder 4 — determination of the correction at the maximum limit

No subtype information

P02D400

Fuel injector cylinder 5 — determination of the correction at the minimum limit

No subtype information

P02D500

Fuel injector cylinder 5 — determination of the correction at the maximum limit

No subtype information

P02D600

Fuel injector of the cylinder 6 — determination of the correction at the minimum limit

No subtype information

P02D700

Fuel injector of the cylinder 6 — determination of the correction at the maximum limit

No subtype information

P02E011

Airflow control at the diesel engine inlet

Short to ground

P02E012

Airflow control at the diesel engine inlet

Circuit Short to Battery Voltage

P02E013

Airflow control at the diesel engine inlet

Open circuit

P02E07C

Airflow control at the diesel engine inlet

Slow reaction

P02E09B

Airflow control at the diesel engine inlet

High / excessive flow

P02E09C

Airflow control at the diesel engine inlet

Low / insufficient flow

P02E601

Diesel Engine Admission Regulator Position Sensor

General electrical fault

P02E612

Diesel Engine Admission Regulator Position Sensor

Circuit Short to Battery Voltage

P02E613

Diesel Engine Admission Regulator Position Sensor

Open circuit

P02E697

Diesel Engine Admission Regulator Position Sensor

The operation of the component or system is difficult or blocked

P02E699

Diesel Engine Admission Regulator Position Sensor

Parameter limit exceeded

P03351F

Crankshaft Position Sensor «A»

Intermittent signal in the circuit

P033531

Crankshaft Position Sensor «A»

Missing signal

P033538

Crankshaft Position Sensor «A»

Incorrect signal frequency

P034031

Camshaft position sensor «A» — row 1 or separate sensor

Missing signal

P034038

Camshaft position sensor «A» — row 1 or separate sensor

Incorrect signal frequency

P04007C

Exhaust gas recirculation flow «A»

Slow reaction

P04009B

Exhaust gas recirculation flow «A»

High / excessive flow

P04009C

Exhaust gas recirculation flow «A»

Low / insufficient flow

P040311

Control of EGR «A»

Short to ground

P040312

Control of EGR «A»

Circuit Short to Battery Voltage

P040313

Control of EGR «A»

Open circuit

P040341

Control of EGR «A»

Total checksum error

P040371

Control of EGR «A»

Driven drive

P040392

Control of EGR «A»

Characteristics or malfunctioning

P040901

The differential pressure sensor EGR

General electrical fault

P040912

The differential pressure sensor EGR

Circuit Short to Battery Voltage

P040913

The differential pressure sensor EGR

Open circuit

P040964

The differential pressure sensor EGR

Violation of signal reliability

P040A01

Temperature sensor «A» of the exhaust gas recirculation system

General electrical fault

P040A11

Temperature sensor «A» of the exhaust gas recirculation system

Short to ground

P040A13

Temperature sensor «A» of the exhaust gas recirculation system

Open circuit

P040A64

Temperature sensor «A» of the exhaust gas recirculation system

Violation of signal reliability

P041A11

Temperature sensor circuit «B» of the exhaust gas recirculation system

Short to ground

P041A12

Temperature sensor circuit «B» of the exhaust gas recirculation system

Circuit Short to Battery Voltage

P041A2A

Temperature sensor circuit «B» of the exhaust gas recirculation system

Stuck signal in the range

P042000

The efficiency of the catalyst system is below the threshold

No subtype information

P047001

The gauge of pressure of exhaust gases «A»

General electrical fault

P047012

The gauge of pressure of exhaust gases «A»

Circuit Short to Battery Voltage

P047013

The gauge of pressure of exhaust gases «A»

Open circuit

P047064

The gauge of pressure of exhaust gases «A»

Violation of signal reliability

P047511

Exhaust Pressure Control Valve «A»

Short to ground

P047512

Exhaust Pressure Control Valve «A»

Circuit Short to Battery Voltage

P047513

Exhaust Pressure Control Valve «A»

Open circuit

P047572

Exhaust Pressure Control Valve «A»

The actuator jammed in the open position

P048011

Fan control circuit 1

Short to ground

P048012

Fan control circuit 1

Circuit Short to Battery Voltage

P048013

Fan control circuit 1

Open circuit

P048613

Sensor «B» of the EGR system

Open circuit

P049D99

Control position «A» EGR exceeded the threshold of training

Parameter limit exceeded

P04D900

Control of the closed loop EGR system at the limit — the flow is too small

No subtype information

P04DA00

Control of the closed loop EGR system at the limit — the flow is too strong

No subtype information

P050011

Vehicle speed by wheel

Short to ground

P050013

Vehicle speed by wheel

Open circuit

P051A01

Crankcase Pressure Sensor

General electrical fault

P051A12

Crankcase Pressure Sensor

Circuit Short to Battery Voltage

P051A13

Crankcase Pressure Sensor

Open circuit

P051A64

Crankcase Pressure Sensor

Violation of signal reliability

P052001

Engine oil pressure switch / relay «A»

General electrical fault

P052012

Engine oil pressure switch / relay «A»

Circuit Short to Battery Voltage

P052013

Engine oil pressure switch / relay «A»

Open circuit

P052064

Engine oil pressure switch / relay «A»

Violation of signal reliability

P052400

Engine oil pressure too low

Engine oil pressure too low

P052607

Fan Speed ​​Sensor Circuit

Mechanical faults

P052612

Fan Speed ​​Sensor Circuit

Circuit Short to Battery Voltage

P053E00

Crankcase pressure — too high

No subtype information

P054001

Control of the inlet air heater «A»

General electrical fault

P054011

Control of the inlet air heater «A»

Short to ground

P054013

Control of the inlet air heater «A»

Open circuit

P054070

Control of the inlet air heater «A»

Drive stuck when on

P05407F

Control of the inlet air heater «A»

Drive stuck when turned off

P054464

Exhaust temperature sensor — Row 1 Sensor 1

Violation of signal reliability

P055A01

Engine oil pressure switch / relay «B»

General electrical fault

P055A12

Engine oil pressure switch / relay «B»

Circuit Short to Battery Voltage

P055A13

Engine oil pressure switch / relay «B»

Open circuit

P055A64

Engine oil pressure switch / relay «B»

Violation of signal reliability

P055F00

Engine oil pressure out of range

No subtype information

P05E311

Parking brake sensor / switch circuit

Short to ground

P05E362

Parking brake sensor / switch circuit

Signal comparison error

P05E364

Parking brake sensor / switch circuit

Violation of signal reliability

P061511

Starter relay

Short to ground

P061512

Starter relay

Circuit Short to Battery Voltage

P061513

Starter relay

Open circuit

P06279C

Fuel pump control «A»

Low / insufficient flow

P064111

Sensor reference voltage «A»

Short to ground

P064112

Sensor reference voltage «A»

Circuit Short to Battery Voltage

P06411C

Sensor reference voltage «A»

Output from the voltage range in the circuit

P065111

Sensor reference voltage «V»

Short to ground

P066601

Internal temperature sensor for control module «A»

General electrical fault

P066611

Internal temperature sensor for control module «A»

Short to ground

P06B016

Sensor supply voltage «A»

Voltage in the circuit below the threshold

P06B017

Sensor supply voltage «A»

Voltage in the circuit above the threshold

P06B316

Sensor supply «B»

Voltage in the circuit below the threshold

P06B317

Sensor supply «B»

Voltage in the circuit above the threshold

P06DA71

Engine Oil Pressure Adjustment

Driven drive

P06E616

Sensor supply voltage «C»

Voltage in the circuit below the threshold

P06E617

Sensor supply voltage «C»

Voltage in the circuit above the threshold

P073021

Recommended transfer

The amplitude of the signal is less than the minimum

P073022

Recommended transfer

The amplitude of the signal above the maximum value

P07307C

Recommended transfer

Slow reaction

P100101

Engine stop switch

General electrical fault

P100111

Engine stop switch

Short to ground

P100112

Engine stop switch

Circuit Short to Battery Voltage

P100190

Engine stop switch

Clogged in the open position

P100192

Engine stop switch

Characteristics or malfunctioning

P100211

Pre-heater heater relay

Short to ground

P100212

Pre-heater heater relay

Circuit Short to Battery Voltage

P100213

Pre-heater heater relay

Open circuit

P100701

Air filter indicator

General electrical fault

P100711

Air filter indicator

Short to ground

P100712

Air filter indicator

Circuit Short to Battery Voltage

P100713

Air filter indicator

Open circuit

P101711

Valve for draining water from fuel

Short to ground

P101E11

The valve of full blocking of the channel of a transmission

Short to ground

P101E12

The valve of full blocking of the channel of a transmission

Circuit Short to Battery Voltage

P101E13

The valve of full blocking of the channel of a transmission

Open circuit

P102111

Volvo Compression Brake Control Circuit (VCB)

Short to ground

P102112

Volvo Compression Brake Control Circuit (VCB)

Circuit Short to Battery Voltage

P102113

Volvo Compression Brake Control Circuit (VCB)

Open circuit

P108600

The oil level is moderately low

No subtype information

P109300

Engine oil pressure is moderately low

No subtype information

P10C011

Volvo Compression Brake Control Circuit (VCB) «2»

Short to ground

P10C012

Volvo Compression Brake Control Circuit (VCB) «2»

Circuit Short to Battery Voltage

P10C013

Volvo Compression Brake Control Circuit (VCB) «2»

Open circuit

P10E100

Differential pressure in particulate filter is critical

No subtype information

P10E200

Differential pressure on particulate filter moderately high

No subtype information

P10F800

Air filter clogged

No subtype information

P10FE00

Clogging of particulate filter — soot accumulation moderately high — row 1

No subtype information

P110400

Factory setting

No subtype information

P110501

Back-up switch circuit «A» of the engine

General electrical fault

P110511

Back-up switch circuit «A» of the engine

Short to ground

P110512

Back-up switch circuit «A» of the engine

Circuit Short to Battery Voltage

P110573

Back-up switch circuit «A» of the engine

The actuator jammed in the closed position

P111600

Absolute pressure sensor in the reservoir is a moderate excess

No subtype information

P111800

Absolute pressure sensor in the collector — a strong excess

No subtype information

P111945

The intake manifold temperature is too high at a moderate level

Failure of program memory

P111A00

Intake manifold temperature too high

No subtype information

P111D00

The engine coolant level is moderately low

No subtype information

P111E00

Engine coolant temperature is moderately high

No subtype information

P112500

Engine oil temperature — moderately high

No subtype information

P112800

The oil pressure for cooling the pistons is moderately low

No subtype information

P112900

Transmission oil temperature moderately high

No subtype information

P112B00

The turbocharger / turbocharger drive temperature «A»

No subtype information

P112E00

Exhaust gas temperature moderately high — row 1

No subtype information

P113411

Air purge valve for fuel injection into the exhaust aftertreatment system

Short to ground

P113413

Air purge valve for fuel injection into the exhaust aftertreatment system

Open circuit

P113472

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the open position

P113473

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the closed position

P113500

Crankcase pressure too high relative to atmospheric pressure

No subtype information

P113600

Error of calibration of the correlation of NOx 1/2 sensors — row 1

No subtype information

P113711

Oil thermostat

Short to ground

P113712

Oil thermostat

Circuit Short to Battery Voltage

P113713

Oil thermostat

Open circuit

P113F11

Idling switch confirmation cable with buffering — VECU side

Short to ground

P113F12

Idling switch confirmation cable with buffering — VECU side

Circuit Short to Battery Voltage

P114000

Volvo Compression Brake Control (VCB) — too low oil temperature

No subtype information

P114101

Idling switch confirmation cable with buffering — ECM side

General electrical fault

P114113

Idling switch confirmation cable with buffering — ECM side

Open circuit

P114123

Idling switch confirmation cable with buffering — ECM side

Constantly low signal level

P114124

Idling switch confirmation cable with buffering — ECM side

Constantly high signal level

P114411

High voltage side of the starter relay

Short to ground

P114412

High voltage side of the starter relay

Circuit Short to Battery Voltage

P114413

High voltage side of the starter relay

Open circuit

P114500

The level of the reducing agent is moderately low

No subtype information

P114700

Pressure in the fuel distribution pipe / system, row 1 — moderately too high

No subtype information

P114B00

The turbocharger / turbocharger drive temperature «A» is too low

No subtype information

P114E00

EGR drive temperature outside the operating range

No subtype information

P115000

Correlation of Sensor / Switch Voltage «A» / «D» Throttle Position / Pedal Position

No subtype information

P115100

Excess temperature of the post-treatment system

No subtype information

P115211

Starting fuel pump

Short to ground

P115212

Starting fuel pump

Circuit Short to Battery Voltage

P115213

Starting fuel pump

Open circuit

P115400

The connection between the bodywork control module «A» and the instrument cluster control module (IPC)

No subtype information

P117311

Low Transmission Range Authorization Valve

Short to ground

P117312

Low Transmission Range Authorization Valve

Circuit Short to Battery Voltage

P117313

Low Transmission Range Authorization Valve

Open circuit

P117401

Transmission range inquiry

General electrical fault

P117411

Transmission range inquiry

Short to ground

P117412

Transmission range inquiry

Circuit Short to Battery Voltage

P117600

Starter motor is deactivated — temperature rise

No subtype information

P117700

Starter motor is deactivated — gearbox is not in neutral position

No subtype information

P117800

The starter motor is deactivated — the gear of the electric motor of the starter motor is stuck

No subtype information

P117900

Starter motor is deactivated — power take-off is active

No subtype information

P117B01

Temperature sensor switch in engine compartment

General electrical fault

P117B11

Temperature sensor switch in engine compartment

Short to ground

P117B12

Temperature sensor switch in engine compartment

Circuit Short to Battery Voltage

P117C00

The requested range of gears is too high

No subtype information

P117D00

Requested driver transfer too low

No subtype information

P117E00

Driver’s request is too high

No subtype information

P117F11

Bypass valve of the hydraulic valve

Short to ground

P117F12

Bypass valve of the hydraulic valve

Circuit Short to Battery Voltage

P117F13

Bypass valve of the hydraulic valve

Open circuit

P203164

Exhaust temperature sensor — Row 1 Sensor 2

Violation of signal reliability

P203A86

Reagent level sensor «A»

Invalid signal

P203F00

Reducer level is low

No subtype information

P204F93

Characteristics of the SCR system — dosing failure

Does not work

P207F9A

Quality of the reducing agent

Working conditions of a component or system

P20D711

Controlling the fuel supply to the exhaust aftertreatment system

Short to ground

P20D713

Controlling the fuel supply to the exhaust aftertreatment system

Open circuit

P20D773

Controlling the fuel supply to the exhaust aftertreatment system

The actuator jammed in the closed position

P20DD01

Fuel pressure sensor for exhaust gas aftertreatment

General electrical fault

P20DD12

Fuel pressure sensor for exhaust gas aftertreatment

Circuit Short to Battery Voltage

P20DD13

Fuel pressure sensor for exhaust gas aftertreatment

Open circuit

P20EE00

The efficiency of the SCR NOx catalyst is below the threshold (row 1)

No subtype information

P20F400

AdBlue consumption is too low

No subtype information

P20F500

Reducer consumption too high

No subtype information

P210900

Performance characteristics of the «A» minimum limiter of the throttle / pedal position

No subtype information

P213600

Correlation of Sensor / Switch Voltage «A» / «C» Throttle Position / Pedal Position

No subtype information

P215A62

Correlation of vehicle speed with wheel speed

Signal comparison error

P215A64

Correlation of vehicle speed with wheel speed

Violation of signal reliability

P216300

Performance characteristics of the maximum limit sensor «A» of the throttle / pedal position

No subtype information

P220012

NOx sensor — series 1 sensor 1

Circuit Short to Battery Voltage

P220013

NOx sensor — series 1 sensor 1

Open circuit

P22001C

NOx sensor — series 1 sensor 1

Output from the voltage range in the circuit

P220064

NOx sensor — series 1 sensor 1

Violation of signal reliability

P220093

NOx sensor — series 1 sensor 1

Does not work

P222601

Barometric pressure circuit

General electrical fault

P222612

Barometric pressure circuit

Circuit Short to Battery Voltage

P222613

Barometric pressure circuit

Open circuit

P222664

Barometric pressure circuit

Violation of signal reliability

P225C00

Characteristics of the NOx sensor — high level signaling — row 1 sensor 1

No subtype information

P225D00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 1

No subtype information

P225E67

Characteristics of the NOx sensor — high level signaling — row 1 sensor 2

Wrong signal after event

P225F00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 2

No subtype information

P226401

Water sensor in fuel

General electrical fault

P226411

Water sensor in fuel

Short to ground

P226413

Water sensor in fuel

Open circuit

P228D72

The fuel pressure regulator 1 has exceeded the control limits — too high a pressure

The actuator jammed in the open position

P228E00

The fuel pressure regulator 1 has exceeded the training limits — too low a pressure

No subtype information

P228F00

The fuel pressure regulator 1 has exceeded the training limits — too high a pressure

No subtype information

P229E12

NOx sensor — row 1 sensor 2

Circuit Short to Battery Voltage

P229E13

NOx sensor — row 1 sensor 2

Open circuit

P229E1C

NOx sensor — row 1 sensor 2

Output from the voltage range in the circuit

P229E64

NOx sensor — row 1 sensor 2

Violation of signal reliability

P229E93

NOx sensor — row 1 sensor 2

Does not work

P22FB92

Sensor Specifications NOx — Sensor — Row 1 Sensor 1

Characteristics or malfunctioning

P22FE00

Sensor Specifications NOx — Sensor — Row 1 Sensor 2

No subtype information

P242800

Exhaust gas temperature too high

No subtype information

P242A64

Exhaust temperature sensor — Row 1 Sensor 3

Violation of signal reliability

P244A00

Differential pressure on the diesel particulate filter after-treatment 1 is too small (row 1)

No subtype information

P244B00

The differential pressure on the diesel particulate filter after-treatment 1 is too large (row 1)

No subtype information

P244C00

The exhaust gas temperature is too low to regenerate the particulate filter (row 1)

No subtype information

P245264

Particulate filter pressure sensor «A»

Violation of signal reliability

P245700

Coolant efficiency of the exhaust gas recirculation system is below the threshold value

No subtype information

P246300

Clogged particulate filter — soot accumulation — row 1

No subtype information

P249D00

Control of the injection of the reducing agent in a closed loop at the limit — the flow is too small

No subtype information

P249E00

Injection of the reducing agent in a closed loop at the limit — the flow is too high

No subtype information

P249F92

Excessive time for switching to the closed-loop diesel particulate filter regeneration control mode

Characteristics or malfunctioning

P24A000

Control of DPF regeneration in a closed loop at the limit — the temperature is too low

No subtype information

P24A100

Control of DPF regeneration in a closed loop at the limit — the temperature is too high

No subtype information

P24A200

The regeneration of the diesel particulate filter is not complete (row 1)

No subtype information

P24A400

Clogging of the diesel particulate filter — soot accumulation too large (row 1)

No subtype information

P250A11

Engine oil level sensor

Short to ground

P250A13

Engine oil level sensor

Open circuit

P250F00

Engine oil level too low

No subtype information

P253901

Low Fuel Pressure Sensor Circuit

General electrical fault

P253912

Low Fuel Pressure Sensor Circuit

Circuit Short to Battery Voltage

P253913

Low Fuel Pressure Sensor Circuit

Open circuit

P255601

Engine Coolant Level Sensor / Relay

General electrical fault

P255611

Engine Coolant Level Sensor / Relay

Short to ground

P255612

Engine Coolant Level Sensor / Relay

Circuit Short to Battery Voltage

P255613

Engine Coolant Level Sensor / Relay

Open circuit

P256000

Engine Coolant Level — Low

No subtype information

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P259C00

Excessive time for entering the supercharging control of the turbocharger «A» in a closed loop

No subtype information

P25A911

Control oil supply for cooling pistons

Short to ground

P25A912

Control oil supply for cooling pistons

Circuit Short to Battery Voltage

P25A913

Control oil supply for cooling pistons

Open circuit

P25A971

Control oil supply for cooling pistons

Driven drive

P25AE00

The oil pressure for cooling the pistons is too low

No subtype information

P260011

Coolant Pump Control Circuit / Break

Short to ground

P260012

Coolant Pump Control Circuit / Break

Circuit Short to Battery Voltage

P260013

Coolant Pump Control Circuit / Break

Open circuit

P268111

Control of the bypass valve «A» of the engine coolant

Short to ground

P268112

Control of the bypass valve «A» of the engine coolant

Circuit Short to Battery Voltage

P268113

Control of the bypass valve «A» of the engine coolant

Open circuit

P269711

Injection Fuel Injector «A»

Short to ground

P269713

Injection Fuel Injector «A»

Open circuit

P269773

Injection Fuel Injector «A»

The actuator jammed in the closed position

P26977A

Injection Fuel Injector «A»

Fluid leakage or seal failure

P2A1612

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Circuit Short to Battery Voltage

P2A1614

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Short to ground or open

P2A1692

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Characteristics or malfunctioning

P2A1E12

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Circuit Short to Battery Voltage

P2A1E14

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Short to ground or open

P2A1E92

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Characteristics or malfunctioning

U000188

CAN Backbone bus 2 communication network

Bus Off

U001088

CAN Backbone bus 1 of the communication network

Bus Off

U008088

Communication Subnet of the car engine

Bus Off

U010100

Lost Communication With TECU

No subtype information

U010A00

Lost communication with the A module of the exhaust gas recirculation system

No subtype information

U010C00

The communication with the turbocharger / supercharger control module is broken

No subtype information

U012100

The communication with the anti-lock braking system (ABS)

No subtype information

U012900

Lost Communication With Brake Control Module

No subtype information

U014100

Lost connection with VMCU

No subtype information

U014200

Lost connection with the body control module «B»

No subtype information

U015500

Communication with the instrument cluster control module (IPC) is broken

No subtype information

U016700

Lost communication with the car immobilizer control module

No subtype information

U029D00

Communication with NOx sensor «A» is broken

No subtype information

U029E00

The communication with the NOx sensor «B» is broken

No subtype information

U032300

Software incompatibility with the dashboard control module

No subtype information

U033100

Incompatibility of software with the bodywork control module «A»

No subtype information

U042600

From the immobilizer control module of the car, unreliable data

No subtype information

U116600

Lost communication with CIOM

No subtype information

U116900

Lost connection with DACU

No subtype information

U116B00

Communication with TCM on the high-speed communication bus CAN

No subtype information

U116C00

Communication with TCM on the CAN bus of the power plant is broken

No subtype information

U116F00

Communication with the control module of the supply of the reducing agent via the engine subnetwork is broken

No subtype information

U117100

The communication with the control unit of the body equipment via the high-speed communication bus CAN

No subtype information

U117300

The communication with the IPC control unit via the high-speed communication CAN

No subtype information

U117888

CAN bus communication system bus

Bus Off

U1FFF68

Factory mode active

Event details

U300001

Electronic control module

General electrical fault

U300041

Electronic control module

Total checksum error

U300044

Electronic control module

Data memory failure

U300045

Electronic control module

Failure of program memory

U300049

Electronic control module

Internal failure of electronics

U300257

Vehicle Identification Number

Invalid / incompatible software component

U029D and U029E NOx sensor codes: What ‘lost communication’ means

Check Engine

What NOx sensors do

But before we get started on the solutions available to you, let’s take a look at what the NOx sensor does. The diesel NOX sensor has a duel-purpose: it is designed to measure both the nitrogen oxide content (chemical name is NO or NO2), and the oxygen content (chemical name O2) in the exhaust. The NOx sensor is therefore vital in a good, working engine. It is possible to drive for short distances with a faulty NOx sensor, but it will quickly impact the acceleration, and cause lost mileage.

As you did understand this part performs Oxygen (lambda probe’s) work and it does measure NOx content, to make sure engine is running smoothly, fuel efficiency is good and environmental isn’t being affected by nitrogen oxides coming out of the exhaust system.

Nox Sensor

Where are NOx sensors fitted?

So where is the NOx sensor? We find it located a little up from the SCR catalyst, in a position prime for directly measuring the level of NOx gas sent out by the engine. This is partnered by a NOx sensor located just a little down from the SCR catalyst, in the perfect place to measure the performance of the catalyst itself. The NOx sensor A is generally screwed into the exhaust pipe, just behind the catalytic converter.

Nitrogen Oxide sensors are fitted to all EURO 4, EURO 5, EURO 6 standard cars, buses, trucks, vans, tractors, heavy duty equipment or any other 12V or 24V motor vehicle with petrol or diesel combustion engine.

These sensors are used by all car manufacturer such Audi, VW Caddy Golf Passat Touran Sharan, Skoda, Seat Alhambra MPV, BMW, Ford, Land Rover, GMC, Volvo, Opel, Renault, Citroen, Peugeot 3008, Alfa-Romeo, Mercedes-Benz, GM, Chrysler, Chevrolet, Opel Vauxhall Insignia Astra MK6 J MK7 K Zafira C MK3, Mini, Dodge Ram truck, Cummins,  Duramax, Mazda, Nissan, Lexus, Toyota, Fiat, Isuzu and many other.

Symptoms of the faulty NOx sensor

This is a pretty severe problem, so it is advisable to deal with it quickly. But what are the symptoms of U029D and U029E error codes? They include the engine warning light  (also known CEL check engine light) coming on (check your user manual to identify this), ask your local mechanic to check this for you if no voltage being produced by the sensor module, if you are DIY person you can use OBD-II OBD 2 port and scanner to check for error codes.

Additionally when sensor has malfunction car’s engine won’t work as good as before and fuel consumption will increase as well.

Explanation of faulty NOX sensor:

  • U029E00 — Lost communication with NOX sensor B
  • U029E Lost Communication with NOx sensor B
  • U029E-00
  • U029D00 — Lost communication with NOX sensor A
  • U029D
  • U029D00 — Communication with nox sensor has a malfunction
  • U029D — Fault in Communication with the DeNOX system
  • U029D-00
  • U100600 — NOx sensor 1 Bank 1 — No Communication
  • 28992 U029E00 Communication missing incorrect
  • 053302 — NOx Sensor 1 Bank 2
  • U1036-000 U1036000 No Communication

So what’s the solution?

The first things to check are the fuses and wiring. Take a look for any obvious loose wires or blown fuses for an easy fix. If everything seems fully functioning, but the NOx sensor error code remains lit up, then replace the NOx control unit sensor, before replacing inspect connectors and plugs as it is very common that these places were affected by water or moisture so before replacing sensor dry them properly. This will help you to determine whether it is a problem with the sensor itself, or the system which feeds the sensor. If, once you have replaced the sensor, the new NOx sensor does not light up an error code, then you know that the issue was with the NOx sensor itself, and has been fixed. On the other hand, if the new NOx sensor still results in an error code, then it is more likely that the issue is with the system itself. but in mostly of the cases it is related to faulty nitrogen oxide sensor.

Compared to fault codes starting with letter P, for example P2200 P2201 P2202 P229F62 P229E P11CC P11DC P11DB and P20EE there is no cheap fix solution or repair kit, the only way to replace buy whole brand new NOx sensor as the main part which is not repairable was damaged or has failed completely and couldn’t be repaired to ensure safety of your car.

Where to get new sensor and which one is required for my car?

If it’s first time you are dealing with NOXC2, NOXC3, NOXC4 or standard NOx sensor, you must to know that these sensors aren’t universal fitment even they look very similar probe and control unit.

There are thousands of different NOx sensors on the market with different length of probe, different software and hardware inside the ballast (emission control unit) for each manufacturer, for example Mercedes-Benz A0009053403, A0009053503, A0009053603, A0009053603, VW 03L907807AB, 03L907807AF, 03L907807AD and so on, below we did provide a short list of available sensors at our online shop.

To find out which part number and sensor is required for you car there are two ways first one lift up or get under the car, locate sensor which is faulty bank 1 or bank 2 etc remove protection covers if necessary and take a picture of label or any writings located on the control unit.

Another way is to hook up your car with dealer software and ask to check what is original part entered in the system, this way is more expensive as it does require dealer software and to check part number phisically is much more easier and cheaper way to do it.

When you have the crucial information you can search for needed part number online, at local store, dealer or any other channels you want or you can email xenons4u with picture or old part number and we will be more than happy to locate this part used, new, refurbished or aftermarket depending on the budget and availability.

A nice, easy fix, but absolutely integral to the smooth running of your vehicle!

An example list of OEM part numbers, which we can supply:

·         9678570780 5WK96746A SNS146A ·         89463-E0480 5WK96786
·         9675358480 5WK96745A SNS145A ·         68085740AA 5WK96730 SNS12V
·         227905444R 5WK96748 SNS148 ·         A0009056304 5WK97250
·         227908539R 5WK96747 SNS147 ·         A0009053403 5WK96681D
·         03L907807R 5WK96737 ·         A0009059603 A2C12547900-081G
·         4M0907807G 5WK97309 A2C92707800-02 ·         A0009059603 5WK96681E
·         04L907805AR — 04L907805AS — 059907807P ·         A0009053503 5WK96682D
·         4H0907807J — 4G0907807T — 4G0907807E ·         A0009052909 A2C16442800-292
·         8R0907807R — 4M0907807F — 059907807Q ·         A0009053000 5WK96682
·         059907807R — 04L907807S — 8R0907807R ·         A0009052900 5WK96683
·         4M0907807- 4M0907807R — 4M0907807G ·         A0009057000 5WK96682A
·         4N0907807 — 4N0907807B — 8K0907807H ·         A0009057100 5WK96683A
·         03L907807AC A2C10327400-086C ·         A0009053503 5WK96682C
·         04L907805L 5WK97233 ·         A0009053603 5WK96683C
·         03L907807AF A2C10327600-088B SME ·         A0009055100 5WK96681
·         03L907807AD — 03L907807 AD — 5WK96688A ·         A0009056900 5WK96681A
·         03L907807AE ·         A0009053403 5WK96681C
·         8K0907807E — 5WK96688 ·         A0009059803 5WK96683E
·         8K0907807C — 5WK96638B ·         A0101539528 5WK96653C
·         8K0907807D — 5WK96641B ·         A0009050008 A2C12610200-284
·         8K0907807K — 5WK96689A ·         A0009052709 A2C16442400-290
·         8K0907807F — 5WK96689 ·         A0009053109 A2C15463300-02
·         8R0907807G — 5WK96728B ·         A0009053009 A2C15462900-02
·         8R0 907 807 — 8R0907807 — 5WK96712 ·         A0009053606 5WK96682F
·         8R0 907 807 Q — 8R0907807Q ·         A0009059703 5WK96682E
·         8R0 907 807 P — 8R0907807P ·         A0009050108 A2C13684300-286
·         8R0 907 807 A — 8R0907807A — 5WK96728 ·         A0065427218 5WK96677
·         8R0907807L — 5WK97255 ·         A0035428818 5WK96606
·         8R0907807E — 5WK96796 ·         A0009053706 5WK96683F
·         8R0907807F — 5WK96739A ·         A0009050208 A2C13684500-287
·         03L907807 T — 03L907807T — 5WK96798 — A2C10328500-198A ·         A0009053603 5WK96683D
·         076907807 5WK96648A ·         A0009052809 A2C16442600-291
·         03L907807E — 5WK96638C ·         759040204 5WK96650B — 5WK96650C
·         4G0907807AA A2C39767700-01 ·         759040202 5WK96650
·         04L907805CE A2C14860700-01 ·         758712905 5WK96610K
·         04L 907 805 BH — 04L907805BH ·         758712903 5WK96610L
·         04L 907 805 DH — 04L907805DH ·         758712901 5WK96610G
·         04L 907 805 AD — 04L907805AD ·         758051801 5WK96610D
·         04L 907 805 DC — 04L907805DC ·         758712902 5WK96610H
·         04L907805CJ — 04L907805CJ ·         758712905 5WK96610L
·         04L907805AE — 04L907805AE ·         758713001 5WK96621F
·         04L907805BP — 04L907805BP ·         758713005 5WK96621J
·         04L907805AA — 04L907805AA ·         758713003 5WK96621H
·         04L907805F ·         758713002 5WK96621G
·         04L907807AA — 04L907807AA ·         758713005 5WK96621K
·         04L907807AD — 04L907807AD ·         758051701 5WK96621C
·         04L907807F ·         758232601 5WK96621D
·         04L907805E — 04L907805 E — 04L 907 805 E ·         758712701 5WK96621E
·         04L907805C — 04L907805 C — 04L 907 805 C ·         857647101 5WK96699B
·         04L907805G — 04L907805 G — 04L 907 805 G ·         8580410-03 0281007018/19
·         04L907807G — 04L907807 G — 04L 907 807 G ·         8580410-01 0281006556
·         04L907807AT ·         851879101 5WK96699A
·         04L907807BF ·         858984401 5WK96697C 13628589844
·         04L907805AL ·         857646901 5WK96697B
·         04L907807AL ·         858984601 5WK96699C
·         4H0907807L ·         851878901 5WK96697A
·         04L907807A ·         851166601 5WK96699
·         04L907807B ·         851166401 5WK96697
·         8W0907807C — 5WK97258 ·         A0101539528 5WK96653C
·         4M0907807B — 5WK97223 ·         A0101539328 A2C39120900-042C
·         5WK9 7226 — 5WK97226 ·         A0091533628 5WK96616F
·         A2C11875900-254A ·         2011649 5WK96628C
·         03N907807A — 5WK97251 ·         2011650 5WK96626C
·         80A907807B — 5WK97415 — A2C98278900-02 ·         LW8161S 55598161 5WK97227
·         076907807A 5WK96690 ·         LW0097S 55570097 5WK96709A
·         03L907807AB — 5WK96690B — A2C10327800-090C ·         4326873 A045S170 NB1500
·         04L907805AR — A2C39831400-02 ·         SNS142B 5WK96742B A2C95991800-01
·         059907807G — 5WK96685A ·         2872948 A034M378
·         04L907805DG 0281007335/336 ·         5WK96742 SNS142 A2C34947100-01
·         8K0907807F — 5WK96689 ·         12642311 5WK96645C
·         8K0907807J — 5WK97205 ·         05149216AB 5WK96651A
·         4M0907807E — 5WK97261 ·         68197109AA 5WK96799
·         4G0907807S — SNS451_ ·         68227486AA 5WK97360
·         4M0907807G — SNS309 — 5WK97309 ·         SNS360 A2C92496200-01
·         8W0907807B — 5WK97257 ·         68085740AA 5WK96730
·         8R0907807S — SNS456_ ·         68210084AA — 904-6030
·         4M0907807D — 5WK97260 ·         06F907807D — 5WK96603B
·         04L907807G — 5WK97217 ·         06F907807F — 5WK96603B
·         059907807J 5WK97229 ·         06F907807A — 5WK96603
·         8K0907807K 5WK96689A ·         06F907807E — 5WK96603A
·         4G0907807L 5WK97266

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional action is needed

Check:

ETC2 not responding

Lost Communication with TECU

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single

Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Camshaft Position Sensor A Circuit

Range/Performance

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P054415

Measured voltage outside the limits specified by the sensor

Circuit Short To Battery or Open

Fault code set by ACM: IDTC_ENGEXHTEMP_OC

Diagnostic Service 14. No additional action is needed

Check:

Fault code set by ACM: IDTC_ENGEXHTEMP_OC

Exhaust Gas Temperature Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct

Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P007100

No Sub Type Information

Ambient air temp sensor or boost temp sensor faulty Ambient air temp sensor or Boost temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Ambient air temp sensor or Boost temp sensor

Ambient Air Temperature Sensor Range/Performance

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P203F00

No Sub Type Information

No urea dosing

Urea symbol in cluster

Tank almost empty, stop dosing to maintain cooling ECM interpretation  of raw value. Urea level. DST problem.

Diagnostic Service 14. No additional action is needed

Check:

ECM interpretation  of raw value. Urea level. DST problem.

Reductant Level Low

————————————————————————————————————————————————————————————

P205A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank temp sensor Cables

Connectors

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor

————————————————————————————————————————————————————————————

P208064

Signal Plausibility Failure

None

The sensor is not plausible Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220013

Measured voltage outside the limits specified by the sensor

Circuit Open

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220164

Signal Plausibility Failure

Excessive urea dosing (only for SCR system)

Exhaust system leakage Air intake leakage

Nox-sensor

Dosing system (only for SCR system)

Exhaust system Air intake system

Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Dosing system (only for SCR system) Exhaust system

Air intake system Nox-sensor

NOx Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P061600

Measured voltage

below limit

No Sub Type

Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage above limit

No Sub Type Information

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal

Temperature Sensor Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

P20EE00

No Sub Type Information

NOx-conversion reduced by appr. 50%

Possible ammonia smell

Regent out of specification, Dosing performance low Urea specification

Dosing system

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system

SCR NOx Catalyst Efficiency Below Threshold (Bank 1)

————————————————————————————————————————————————————————————

P260013

Measured voltage outside the limits specified by the sensor

Circuit Open

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit/Open

————————————————————————————————————————————————————————————

P260200

Measured voltage below limit

No Sub Type Information

Pump always runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit Low

————————————————————————————————————————————————————————————

P260300

Measured voltage above limit

No Sub Type Information

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit High

————————————————————————————————————————————————————————————

P261087

Missing Message

Timestamps from Cluster not available

J1708 time data failure and J1939 message does not exist. (Cluster error).

Cluster

Diagnostic Service 14. No additional action is needed

Check: Cluster

ECM/PCM Internal Engine Off Timer Performance

————————————————————————————————————————————————————————————

P2BA700

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Empty Reagent Tank

————————————————————————————————————————————————————————————

P023400

No Sub Type Information

Too high pressure Turbine , Compressor

Diagnostic Service 14. No additional action is needed

Check:

Turbine , Compressor

Turbocharger/Supercharg er Overboost Condition

————————————————————————————————————————————————————————————

P029900

No Sub Type Information

Too low pressure

Boost leakage, wastegate, VGT, compressor.

Diagnostic Service 14. No additional action is needed

Check:

Boost leakage, wastegate, VGT, compressor.

Turbocharger/Supercharg er Underboost

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the sensor

General Electrical Failure

Possible damage on EMS system components depending on the high voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software Software download

application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P007087

Missing Message

None

J1708 and CAN ambient air temperature message does not exist.

Harness. Cluster

Diagnostic Service 14. No additional action is needed

Check:

Harness. Cluster

Ambient Air Temperature Sensor “A”

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is

detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

————————————————————————————————————————————————————————————

P051B64

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The crank case pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Engine High Resolution Crankcase Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage

below limit

No Sub Type

Information

Will give water in fuel

indication.

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Water In Fuel Indicator

Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Level Circuit Low

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

P20BF00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 2 Short Circuit Low

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P109000

No Sub Type Information

Display of the message, without bip, simultaneously with the gear engaged pictogram

Driver started at too high gear at start

Protective alert for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective alert for clutch/transmission

Transmission High Gear At Start

————————————————————————————————————————————————————————————

P208E00

No Sub Type Information

No urea dosing

Sensor/Harness dosing valve

injector, clogged hoses

Diagnostic Service 14. No additional action is needed

Check:

dosing valve

injector, clogged hoses

Aftertreatment Reagent Dosing Valve Clogged

————————————————————————————————————————————————————————————

P109541

General Checksum Failure

Engine derate

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Control Unit

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or always activated if fault is

intermittent.

Broken actuator, wire or ECM driver output

Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P220E93

No Operation

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Heater Control Circuit Range/Performance (Bank

1 Sensor 1)

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P220300

No Sub Type Information

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Circuit High Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P2BA800

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Interruption of Reagent Dosing Activity

————————————————————————————————————————————————————————————

P2BA900

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality

————————————————————————————————————————————————————————————

P2BAA00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Low Reagent Consumption

————————————————————————————————————————————————————————————

P2BAD00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown

————————————————————————————————————————————————————————————

P2BAE96

Component Internal Failure

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100629

Signal invalid

None

The boost temperature sensor output is showing constant value.

Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Intake Air Temperature Sensor 1 Stuck Bank 1

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

U010E00

Lost communication with the node

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Reductant Control

Module

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P204A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Reductant Pressure Sensor

————————————————————————————————————————————————————————————

P203D00

Measured voltage above limit

No Sub Type Information

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Aftertreatment Reagent Level  Short Circuit High

————————————————————————————————————————————————————————————

P208A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Reductant Pump “A” Control

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P054500

Measured voltage below limit

No Sub Type Information

Fault code set by ACM: IDTC_ENGEXHTEMP_SCL

Diagnostic Service 14. No additional action is needed

Check:

Fault code set by ACM: IDTC_ENGEXHTEMP_SCL

Exhaust Gas Temperature Short Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P20B300

Measured voltage below limit

No Sub Type Information

None

.

Diagnostic Service 14. No additional action is needed

.

Reductant Heater Coolant Control Valve Circuit Low

————————————————————————————————————————————————————————————

P204800

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: DCU ACM Pump module: internal cabling

ACM Pump module: DCU,

ACM Pump module: internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: DCU, ACM Pump module: internal cabling

Aftertreatment Reagent Dosing Valve Short Circuit Low

————————————————————————————————————————————————————————————

P204713

Measured voltage outside the limits specified by the sensor

Circuit Open

no urea dosing

Cable / Connectors

ACM Dosing module: Dosing valve

Cable / Connectors ACM Dosing module: Dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Cable / Connectors ACM Dosing module: Dosing valve

Reductant Injection Valve Control Bank 1 Unit 1

————————————————————————————————————————————————————————————

P20C300

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 3 Short Circuit Low

————————————————————————————————————————————————————————————

P20BB00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 1 Short Circuit Low

————————————————————————————————————————————————————————————

P20A200

Measured voltage below limit

No Sub Type Information

Not possible to perform afterrun

Internal electrical failure in valve within the ACM

Diagnostic Service 14. No additional action is needed

Check:

Internal electrical failure in valve within the ACM

Aftertreatment Reagent Direction Valve Short

Circuit Low

————————————————————————————————————————————————————————————

P065900

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit

High

————————————————————————————————————————————————————————————

P065800

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit Low

————————————————————————————————————————————————————————————

P208D00

Measured voltage above limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent

Pump Control Short Circut High

————————————————————————————————————————————————————————————

P208C00

Measured voltage below limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short

Circuit Low

————————————————————————————————————————————————————————————

P203A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Reductant Level Sensor “A”

————————————————————————————————————————————————————————————

P108700

No Sub Type

Information

None

No fault

None

Diagnostic Service 14. No additional

action is needed

Check:

No fault

Injector 1 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P107B00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 2 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P024313

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Broken actuator or wire. Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Turbocharger/Supercharg er Wastegate Solenoid “A”

————————————————————————————————————————————————————————————

P024471

Actuator Stuck

Possible turbo damage

Wategate mechanically damaged

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate  Stuck Close

————————————————————————————————————————————————————————————

P024500

Measured voltage below limit

No Sub Type Information

Broken actuator, wire or ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit Low

————————————————————————————————————————————————————————————

P024600

Measured voltage above limit

No Sub Type Information

Powerloss

Broken actuator, wire or ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

P204300

No Sub Type Information

None

Urea tank temp sensor stuck high

Urea tank temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor

Aftertreatment Reagent Tank Temperature Sensor Stuck

————————————————————————————————————————————————————————————

P209F73

Actuator Stuck Closed

None

Urea tank temp sensor or Urea tank heating system Urea tank temp sensor, Urea tank heating system

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Urea tank heating system

Aftertreatment Reagent Tank Temperature

————————————————————————————————————————————————————————————

P20F400

No Sub Type Information

Too low urea consumption

Urea level sensor stuck Clogged urea system Wrong urea tank Wrong dosing module Nozzle or

ACM Dosing module: dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Nozzle or

ACM Dosing module: dosing valve

AdBlue Consumption Too Low

————————————————————————————————————————————————————————————

P108900

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 3 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P108B00

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Injector 4 Missing Glitch Signature

————————————————————————————————————————————————————————————

P108D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 5 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P108F00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 6 Missing Glitch

Signature

————————————————————————————————————————————————————————————

U029D00

Lost communication with the node

No Sub Type Information

MS from Nox-sensor ECU Nox-sensor power supply CAN communication between ECM and Nox-EUC

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor power supply

CAN communication between ECM and Nox-EUC

Lost Communication With NOx Sensor “A”

————————————————————————————————————————————————————————————

P204C00

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Aftertreatment Reagent Pressure Sensor Circuit Low

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P220A1C

Circuit Voltage Out of Range

Too high voltage to NOx- sensor ECU

Battery voltage

Diagnostic Service 14. No additional action is needed

Check:

Battery voltage

NOx Sensor Supply Voltage Circuit (Bank 1 Sensor 1)

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil Temperature Too Low

————————————————————————————————————————————————————————————

P113711

Measured voltage below limit

Circuit Short To Ground

Oil thermostat alwaysclosed.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P113712

Measured voltage above limit

Circuit Short To Battery

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P113713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P011164

Signal Plausibility Failure

None

The boost temperature sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Ambient air temperature sensor.

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Ambient air temperature sensor.

Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1

————————————————————————————————————————————————————————————

P20E892

Performance or Incorrect Operation

No urea dosing

ACM dosing module: Dosing valve leakage.

Bleed orifice leakage, pressure hose lekage, pump internal leakage, empty ureatank

Tank frozen.

if pump/tank-lines are mixed-up when connecting them to the pump unit there will be no pressure built (check color mar Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Diagnostic Service 14. No additional action is needed

Check:

Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Reductant Pressure Too Low

————————————————————————————————————————————————————————————

P21CA00

No Sub Type Information

No dozing

Voltage supply to ACM.

Voltage supply to Urea pump.

Diagnostic Service 14. No additional action is needed

Check:

Voltage supply to Urea pump.

Reductant Control Module Supply Voltage

————————————————————————————————————————————————————————————

P114411

Measured voltage

below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage above limit

Circuit Short To Battery

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P116A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side

————————————————————————————————————————————————————————————

P116B00

Measured voltage below limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A”

Control Low Side Circuit Low

————————————————————————————————————————————————————————————

P116C00

Measured voltage above limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit

High

————————————————————————————————————————————————————————————

P020A25

Signal Shape /

Waveform Failure

None

No fault

None

Diagnostic Service 14. No additional

action is needed

Check:

No fault

Cylinder 1 Injection

Timing

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P115C00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “C” Circuit High

————————————————————————————————————————————————————————————

P115D00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “C” Circuit Low

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P115E97

Component or System Operation Obstructed or Blocked

No dozing

Bleed orifice clogged

Bleed orifice, Urea pressure sensor,

Diagnostic Service 14. No additional action is needed

Check:

Bleed orifice, Urea pressure sensor,

Reductant Return No Flow Detected

————————————————————————————————————————————————————————————

P11609B

High/Excessive Flow

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown (First Level)

————————————————————————————————————————————————————————————

P116192

Performance or Incorrect Operation

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality (First Level)

————————————————————————————————————————————————————————————

P116300

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System (First Level)

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P115600

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “A” Circuit High

————————————————————————————————————————————————————————————

P115700

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “A” Circuit Low

————————————————————————————————————————————————————————————

P115800

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control

Module Sensor Power Supply “B” Circuit High

————————————————————————————————————————————————————————————

P115900

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power

Supply “B” Circuit Low

————————————————————————————————————————————————————————————

P115A00

No Sub Type Information

Possible incread risk of crystalization

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Exhaust Gas Temperature Sensor Circuit Signal Compare Failure Bank 1

Sensor 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P115B00

No Sub Type Information

None

The sensor is stuck Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Stuck Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P116441

General Checksum Failure

All ACM functionality disabled, no urea dosing

No software in ACM

.

Diagnostic Service 14. No additional action is needed

Check:

No software in ACM

Reductant Control Module Internal Control Module Memory Checksum Error

————————————————————————————————————————————————————————————

P116500

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at low speed but still shifts to high gear, range high.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too High Gear

————————————————————————————————————————————————————————————

P116600

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at high speed but still down-shift to low gear, range low.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too Low Gear

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

P24FF00

No Sub Type Information

If tank temp is too high, no urea dosing

Urea tank temp is too high Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Reductant Temperature Too High

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P117A00

No Sub Type Information

Possible ammonia smell

SCR catalyst removed, Regent out of specification, Clogged dosing system Urea specification

Dosing system Catalyst deactivated

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system Catalyst deactivated

SCR NOx Catalyst Efficiency Critically Below Threshold Bank 1

————————————————————————————————————————————————————————————

P047800

Measured voltage

above limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P222764

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The ambient air pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Sensor “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P020D25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 4 Injection

Timing

————————————————————————————————————————————————————————————

P020E25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 5 Injection

Timing

————————————————————————————————————————————————————————————

P020F25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 6 Injection

Timing

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P020B25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 2 Injection

Timing

————————————————————————————————————————————————————————————

P020C25

Signal Shape / Waveform Failure

.

Diagnostic Service 14. No additional action is needed

.

Cylinder 3 Injection Timing

————————————————————————————————————————————————————————————

P205E1F

Circuit Intermittent

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor Circuit

Intermittent/Erratic

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P25AB00

Measured voltage above limit

No Sub Type Information

Possible black smoke during start.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control Circuit High

————————————————————————————————————————————————————————————

P25AA00

Measured voltage below limit

No Sub Type Information

No piston cooling=>major engine damage if high

loads.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control Circuit Low

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P010662

Signal Compare Failure

Powerloss Black smoke

The boost pressure sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P25AE00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Piston Cooling Oil

Pressure Too Low

————————————————————————————————————————————————————————————

P25A913

Measured voltage outside the limits specified by the

sensor

Circuit Open

Possible black smoke during start.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P225D00

No Sub Type Information

None except fault code and lamp

Sensor removed (measures surround air)

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Signal Stuck Low Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

————————————————————————————————————————————————————————————

P22FB00

No Sub Type Information

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Sensing Element Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P110F90

Stuck On

Stop switch can not be activated

Switch

Engine stop switch

Diagnostic Service 14. No additional action is needed

Check:

Engine stop switch

Engine Stop Switch Stuck

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P055A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

.

Diagnostic Service 14. No additional action is needed

.

Engine Oil Pressure Sensor/Switch “B”

————————————————————————————————————————————————————————————

P055B64

Signal Plausibility Failure

The control function closes the PCJ valve. When the fault is set, the PCJ oil pressure is forced to max (if calibrated so in the pcj_ function).

The sensor is stuck, has an offset or another kind of rationality fault. It could also be the valve that cannot be closed.

Sensor/Valve

Diagnostic Service 14. No additional action is needed

Check: Sensor/Valve

Piston Cooling Oil Pressure Sensor Range/Performance

————————————————————————————————————————————————————————————

P055D00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P112800

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Moderately Low

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Moderately Too

High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Engine Coolant Level Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Low Pressure Fuel System Sensor Circuit High

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Camshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the

sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P054415

Measured voltage outside the limits specified by the

sensor

Circuit Short To Battery or Open

Fault code set by ACM: IDTC_ENGEXHTEMP_OC

Diagnostic Service 14. No additional action is needed

Check:

Fault code set by ACM: IDTC_ENGEXHTEMP_OC

Exhaust Gas Temperature Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct

Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P007100

No Sub Type Information

Ambient air temp sensor or boost temp sensor faulty Ambient air temp sensor or Boost temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Ambient air temp sensor or Boost temp sensor

Ambient Air Temperature Sensor Range/Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P203F00

No Sub Type Information

No urea dosing

Urea symbol in cluster

Tank almost empty, stop dosing to maintain cooling ECM interpretation  of raw value. Urea level. DST problem.

Diagnostic Service 14. No additional action is needed

Check:

ECM interpretation  of raw value. Urea level. DST problem.

Reductant Level Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P205A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank temp sensor Cables

Connectors

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor

————————————————————————————————————————————————————————————

P208064

Signal Plausibility Failure

None

The sensor is not plausible Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220013

Measured voltage outside the limits specified by the sensor

Circuit Open

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220164

Signal Plausibility Failure

Excessive urea dosing (only for SCR system)

Exhaust system leakage Air intake leakage

Nox-sensor

Dosing system (only for SCR system)

Exhaust system Air intake system

Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Dosing system (only for SCR system) Exhaust system

Air intake system Nox-sensor

NOx Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the

sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

————————————————————————————————————————————————————————————

P061600

Measured voltage

below limit

No Sub Type

Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage

above limit

No Sub Type

Information

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal Temperature Sensor Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

P20EE00

No Sub Type Information

NOx-conversion reduced by appr. 50%

Possible ammonia smell

Regent out of specification, Dosing performance low Urea specification

Dosing system

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system

SCR NOx Catalyst Efficiency Below Threshold (Bank 1)

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P260013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit/Open

————————————————————————————————————————————————————————————

P260200

Measured voltage below limit

No Sub Type Information

Pump always runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit Low

————————————————————————————————————————————————————————————

P260300

Measured voltage above limit

No Sub Type Information

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit High

————————————————————————————————————————————————————————————

P261087

Missing Message

Timestamps from Cluster not available

J1708 time data failure and J1939 message does not exist. (Cluster error).

Cluster

Diagnostic Service 14. No additional action is needed

Check: Cluster

ECM/PCM Internal Engine Off Timer Performance

————————————————————————————————————————————————————————————

P2BA700

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Empty Reagent Tank

————————————————————————————————————————————————————————————

P023400

No Sub Type Information

Too high pressure Turbine , Compressor

Diagnostic Service 14. No additional action is needed

Check:

Turbine , Compressor

Turbocharger/Supercharg er Overboost Condition

————————————————————————————————————————————————————————————

P029900

No Sub Type Information

Too low pressure

Boost leakage, wastegate, VGT, compressor.

Diagnostic Service 14. No additional action is needed

Check:

Boost leakage, wastegate, VGT, compressor.

Turbocharger/Supercharg er Underboost

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the

sensor

General Electrical Failure

Possible damage on EMS system components depending on the high

voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software Software download

application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

————————————————————————————————————————————————————————————

P007087

Missing Message

None

J1708 and CAN ambient air temperature message does not exist.

Harness. Cluster

Diagnostic Service 14. No additional action is needed

Check:

Harness. Cluster

Ambient Air Temperature Sensor “A”

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start.

Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P051B64

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The crank case pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Engine High Resolution Crankcase Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check:

Sensor ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage

below limit

No Sub Type

Information

Will give water in fuel

indication.

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Water In Fuel Indicator

Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Engine Oil Level Circuit Low

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

P20BF00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 2 Short Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P109000

No Sub Type Information

Display of the message, without bip, simultaneously with the gear engaged

pictogram

Driver started at too high gear at start

Protective alert for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective alert for clutch/transmission

Transmission High Gear At Start

————————————————————————————————————————————————————————————

P208E00

No Sub Type Information

No urea dosing

Sensor/Harness dosing valve

injector, clogged hoses

Diagnostic Service 14. No additional action is needed

Check:

dosing valve

injector, clogged hoses

Aftertreatment Reagent Dosing Valve Clogged

————————————————————————————————————————————————————————————

P109541

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Aftertreatment Control

Unit

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or always activated if fault is intermittent.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P220E93

No Operation

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Heater Control Circuit Range/Performance (Bank

1 Sensor 1)

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P220300

No Sub Type Information

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Circuit High Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P2BA800

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Interruption of Reagent Dosing Activity

————————————————————————————————————————————————————————————

P2BA900

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P2BAA00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Low Reagent Consumption

————————————————————————————————————————————————————————————

P2BAD00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown

————————————————————————————————————————————————————————————

P2BAE96

Component Internal Failure

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn

off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100629

Signal invalid

None

The boost temperature sensor output is showing constant value.

Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Intake Air Temperature Sensor 1 Stuck Bank 1

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

U010E00

Lost communication with the node

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Reductant Control

Module

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P204A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Reductant Pressure Sensor

————————————————————————————————————————————————————————————

P203D00

Measured voltage above limit

No Sub Type Information

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Aftertreatment Reagent Level  Short Circuit High

————————————————————————————————————————————————————————————

P208A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Reductant Pump “A” Control

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P054500

Measured voltage below limit

No Sub Type Information

Fault code set by ACM: IDTC_ENGEXHTEMP_SCL

Diagnostic Service 14. No additional action is needed

Check:

Fault code set by ACM: IDTC_ENGEXHTEMP_SCL

Exhaust Gas Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P20B300

Measured voltage below limit

No Sub Type Information

None

.

Diagnostic Service 14. No additional action is needed

.

Reductant Heater Coolant Control Valve Circuit Low

————————————————————————————————————————————————————————————

P204800

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: DCU ACM Pump module: internal cabling

ACM Pump module: DCU,

ACM Pump module: internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: DCU, ACM Pump module: internal cabling

Aftertreatment Reagent Dosing Valve Short Circuit Low

————————————————————————————————————————————————————————————

P204713

Measured voltage outside the limits specified by the sensor

Circuit Open

no urea dosing

Cable / Connectors

ACM Dosing module: Dosing valve

Cable / Connectors ACM Dosing module: Dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Cable / Connectors ACM Dosing module: Dosing valve

Reductant Injection Valve Control Bank 1 Unit 1

————————————————————————————————————————————————————————————

P20C300

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 3 Short

Circuit Low

————————————————————————————————————————————————————————————

P20BB00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 1 Short

Circuit Low

————————————————————————————————————————————————————————————

P20A200

Measured voltage below limit

No Sub Type Information

Not possible to perform afterrun

Internal electrical failure in valve within the ACM

Diagnostic Service 14. No additional action is needed

Check:

Internal electrical failure in valve within the ACM

Aftertreatment Reagent Direction Valve Short

Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P065900

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit

High

————————————————————————————————————————————————————————————

P065800

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit Low

————————————————————————————————————————————————————————————

P208D00

Measured voltage above limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent

Pump Control Short Circut High

————————————————————————————————————————————————————————————

P208C00

Measured voltage below limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short

Circuit Low

————————————————————————————————————————————————————————————

P203A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Reductant Level Sensor “A”

————————————————————————————————————————————————————————————

P108700

No Sub Type

Information

None

No fault

None

Diagnostic Service 14. No additional

action is needed

Check:

No fault

Injector 1 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P107B00

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Injector 2 Missing Glitch Signature

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P024313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Powerloss

Broken actuator or wire. Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Turbocharger/Supercharg er Wastegate Solenoid “A”

————————————————————————————————————————————————————————————

P024471

Actuator Stuck

Possible turbo damage

Wategate mechanically damaged

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate  Stuck Close

————————————————————————————————————————————————————————————

P024500

Measured voltage below limit

No Sub Type Information

Broken actuator, wire or ECM driver output

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit Low

————————————————————————————————————————————————————————————

P024600

Measured voltage above limit

No Sub Type Information

Powerloss

Broken actuator, wire or ECM driver output

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit High

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

P204300

No Sub Type Information

None

Urea tank temp sensor stuck high

Urea tank temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor

Aftertreatment Reagent Tank Temperature Sensor Stuck

————————————————————————————————————————————————————————————

P209F73

Actuator Stuck Closed

None

Urea tank temp sensor or Urea tank heating system Urea tank temp sensor, Urea tank heating system

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Urea tank heating system

Aftertreatment Reagent Tank Temperature

————————————————————————————————————————————————————————————

P20F400

No Sub Type Information

Too low urea consumption

Urea level sensor stuck Clogged urea system Wrong urea tank Wrong dosing module Nozzle or

ACM Dosing module: dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Nozzle or

ACM Dosing module: dosing valve

AdBlue Consumption Too Low

————————————————————————————————————————————————————————————

P108900

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 3 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P108B00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 4 Missing Glitch

Signature

————————————————————————————————————————————————————————————

P108D00

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Injector 5 Missing Glitch Signature

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P108F00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Injector 6 Missing Glitch

Signature

————————————————————————————————————————————————————————————

U029D00

Lost communication with the node

No Sub Type Information

MS from Nox-sensor ECU Nox-sensor power supply CAN communication between ECM and Nox-EUC

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor power supply

CAN communication between ECM and Nox-EUC

Lost Communication With NOx Sensor “A”

————————————————————————————————————————————————————————————

P204C00

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Aftertreatment Reagent Pressure Sensor Circuit Low

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P220A1C

Circuit Voltage Out of Range

Too high voltage to NOx- sensor ECU

Battery voltage

Diagnostic Service 14. No additional action is needed

Check:

Battery voltage

NOx Sensor Supply Voltage Circuit (Bank 1 Sensor 1)

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil Temperature Too Low

————————————————————————————————————————————————————————————

P113711

Measured voltage below limit

Circuit Short To Ground

Oil thermostat alwaysclosed.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P113712

Measured voltage above limit

Circuit Short To Battery

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P113713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P011164

Signal Plausibility Failure

None

The boost temperature sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Ambient air temperature sensor.

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Ambient air temperature sensor.

Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P20E892

Performance or Incorrect Operation

No urea dosing

ACM dosing module: Dosing valve leakage.

Bleed orifice leakage, pressure hose lekage, pump internal leakage, empty ureatank

Tank frozen.

if pump/tank-lines are mixed-up when connecting them to the pump unit there will be no pressure built (check color mar Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Diagnostic Service 14. No additional action is needed

Check:

Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Reductant Pressure Too Low

————————————————————————————————————————————————————————————

P21CA00

No Sub Type Information

No dozing

Voltage supply to ACM.

Voltage supply to Urea pump.

Diagnostic Service 14. No additional action is needed

Check:

Voltage supply to Urea pump.

Reductant Control Module Supply Voltage

————————————————————————————————————————————————————————————

P114411

Measured voltage below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage

above limit

Circuit Short To Battery

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P116A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side

————————————————————————————————————————————————————————————

P116B00

Measured voltage below limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit

Low

————————————————————————————————————————————————————————————

P116C00

Measured voltage above limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit

High

————————————————————————————————————————————————————————————

P020A25

Signal Shape /

Waveform Failure

None

No fault

None

Diagnostic Service 14. No additional

action is needed

Check:

No fault

Cylinder 1 Injection

Timing

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P115C00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “C” Circuit High

————————————————————————————————————————————————————————————

P115D00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “C” Circuit Low

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P115E97

Component or System Operation Obstructed or Blocked

No dozing

Bleed orifice clogged

Bleed orifice, Urea pressure sensor,

Diagnostic Service 14. No additional action is needed

Check:

Bleed orifice, Urea pressure sensor,

Reductant Return No Flow Detected

————————————————————————————————————————————————————————————

P11609B

High/Excessive Flow

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown (First Level)

————————————————————————————————————————————————————————————

P116192

Performance or Incorrect Operation

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality (First Level)

————————————————————————————————————————————————————————————

P116300

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System (First Level)

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P115600

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “A” Circuit High

————————————————————————————————————————————————————————————

P115700

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “A” Circuit Low

————————————————————————————————————————————————————————————

P115800

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control

Module Sensor Power Supply “B” Circuit High

————————————————————————————————————————————————————————————

P115900

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power Supply “B” Circuit Low

————————————————————————————————————————————————————————————

P115A00

No Sub Type Information

Possible incread risk of crystalization

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Exhaust Gas Temperature Sensor Circuit Signal Compare Failure Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P115B00

No Sub Type Information

None

The sensor is stuck Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Stuck Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P116441

General Checksum Failure

All ACM functionality disabled, no urea dosing

No software in ACM

.

Diagnostic Service 14. No additional action is needed

Check:

No software in ACM

Reductant Control Module Internal Control Module Memory Checksum Error

————————————————————————————————————————————————————————————

P116500

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at low speed but still shifts to high gear, range high.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too High Gear

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P116600

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at high speed but still down-shift to low gear, range low.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too Low Gear

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum Failure

The engine can not be started

.

Diagnostic Service 14. No additional action is needed

.

Control Module

————————————————————————————————————————————————————————————

P24FF00

No Sub Type Information

If tank temp is too high, no urea dosing

Urea tank temp is too high Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Reductant Temperature Too High

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional

action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P117A00

No Sub Type Information

Possible ammonia smell

SCR catalyst removed, Regent out of specification, Clogged dosing system Urea specification

Dosing system Catalyst deactivated

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system Catalyst deactivated

SCR NOx Catalyst Efficiency Critically Below Threshold Bank 1

————————————————————————————————————————————————————————————

P047800

Measured voltage

above limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage below limit

No Sub Type Information

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A” Low

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P222764

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The ambient air pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Sensor “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P020D25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 4 Injection

Timing

————————————————————————————————————————————————————————————

P020E25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 5 Injection

Timing

————————————————————————————————————————————————————————————

P020F25

Signal Shape / Waveform Failure

.

Diagnostic Service 14. No additional action is needed

.

Cylinder 6 Injection Timing

————————————————————————————————————————————————————————————

P020B25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 2 Injection

Timing

————————————————————————————————————————————————————————————

P020C25

Signal Shape /

Waveform Failure

.

Diagnostic Service 14. No additional

action is needed

.

Cylinder 3 Injection

Timing

————————————————————————————————————————————————————————————

P205E1F

Circuit Intermittent

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor Circuit Intermittent/Erratic

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P25AB00

Measured voltage

above limit

No Sub Type

Information

Possible black smoke during

start.

Harness/Broken actuator

Harness/Valve

Diagnostic Service 14. No additional

action is needed

Check:

Harness/Valve

Piston Cooling Oil Control

Circuit High

————————————————————————————————————————————————————————————

P25AA00

Measured voltage below limit

No Sub Type Information

No piston cooling=>major engine damage if high

loads.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control Circuit Low

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P010662

Signal Compare Failure

Powerloss Black smoke

The boost pressure sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P25AE00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Piston Cooling Oil

Pressure Too Low

————————————————————————————————————————————————————————————

P25A913

Measured voltage outside the limits specified by the sensor

Circuit Open

Possible black smoke during start.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P225D00

No Sub Type Information

None except fault code and lamp

Sensor removed (measures surround air)

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Signal Stuck Low Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

————————————————————————————————————————————————————————————

P22FB00

No Sub Type Information

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Sensing Element Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P110F90

Stuck On

Stop switch can not be activated

Switch

Engine stop switch

Diagnostic Service 14. No additional action is needed

Check:

Engine stop switch

Engine Stop Switch Stuck

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional

action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P055A13

Measured voltage outside the limits specified by the sensor

Circuit Open

.

Diagnostic Service 14. No additional action is needed

.

Engine Oil Pressure Sensor/Switch “B”

————————————————————————————————————————————————————————————

P055B64

Signal Plausibility Failure

The control function closes the PCJ valve. When the fault is set, the PCJ oil pressure is forced to max (if calibrated so in the pcj_ function).

The sensor is stuck, has an offset or another kind of rationality fault. It could also be the valve that cannot be closed.

Sensor/Valve

Diagnostic Service 14. No additional action is needed

Check: Sensor/Valve

Piston Cooling Oil Pressure Sensor Range/Performance

————————————————————————————————————————————————————————————

P055D00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Sensor Circuit

High

————————————————————————————————————————————————————————————

P112800

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Moderately Low

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Moderately Too

High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Engine Coolant Level

Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit High

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Camshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the

sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P054415

Measured voltage above limit

Circuit Short To Battery or Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Exhaust Gas Temperature Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct

Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type Information

Not possible to reprogram ECU

.

Diagnostic Service 14. No additional action is needed

.

Control Module Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the

sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

————————————————————————————————————————————————————————————

P061600

Measured voltage below limit

No Sub Type Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage

above limit

No Sub Type

Information

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal Temperature Sensor

Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the sensor

General Electrical Failure

Possible damage on EMS system components depending on the high voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software

Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is

detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage

below limit

No Sub Type

Information

Will give water in fuel

indication.

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Water In Fuel Indicator

Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Engine Oil Level Circuit Low

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P109000

No Sub Type Information

Display of the message, without bip, simultaneously with the gear engaged

pictogram

Driver started at too high gear at start

Protective alert for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective alert for clutch/transmission

Transmission High Gear At Start

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or always activated if fault is

intermittent.

Broken actuator, wire or ECM driver output

Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P054500

Measured voltage below limit

No Sub Type Information

None

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Exhaust Gas Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil

Temperature Too Low

————————————————————————————————————————————————————————————

P114411

Measured voltage

below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage above limit

Circuit Short To Battery

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P116500

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at low speed but still shifts to high gear, range high.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too High Gear

————————————————————————————————————————————————————————————

P116600

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at high speed but still down-shift to low gear, range low.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too Low Gear

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional

action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P047800

Measured voltage

above limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

————————————————————————————————————————————————————————————

P110F90

Stuck On

Stop switch can not be

activated

Switch

Engine stop switch

Diagnostic Service 14. No additional

action is needed

Check:

Engine stop switch

Engine Stop Switch Stuck

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute

Pressure Moderately Too High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Engine Coolant Level Moderately Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Low Pressure Fuel System Sensor Circuit High

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single

Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Camshaft Position Sensor A Circuit

Range/Performance

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the

sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P054415

Measured voltage above limit

Circuit Short To Battery or Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Exhaust Gas Temperature Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the

sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

————————————————————————————————————————————————————————————

P061600

Measured voltage

below limit

No Sub Type

Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage above limit

No Sub Type Information

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal Temperature Sensor

Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the

sensor

General Electrical Failure

Possible damage on EMS system components depending on the high

voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software Software download

application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Pressure Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check:

Sensor ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check:

Sensor ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage below limit

No Sub Type Information

Will give water in fuel indication.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Level Circuit Low

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P109000

No Sub Type Information

Display of the message, without bip, simultaneously with the gear engaged pictogram

Driver started at too high gear at start

Protective alert for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective alert for clutch/transmission

Transmission High Gear At Start

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or always activated if fault is

intermittent.

Broken actuator, wire or ECM driver output

Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn

off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P054500

Measured voltage below limit

No Sub Type Information

None

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Exhaust Gas Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil Temperature Too Low

————————————————————————————————————————————————————————————

P114411

Measured voltage below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage

above limit

Circuit Short To Battery

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P116500

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at low speed but still shifts to high gear, range high.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too High Gear

————————————————————————————————————————————————————————————

P116600

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at high speed but still down-shift to low gear, range low.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too Low Gear

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P047800

Measured voltage

above limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

————————————————————————————————————————————————————————————

P110F90

Stuck On

Stop switch can not be activated

Switch

Engine stop switch

Diagnostic Service 14. No additional action is needed

Check:

Engine stop switch

Engine Stop Switch Stuck

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional

action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Moderately Too High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Engine Coolant Level

Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Camshaft Position Sensor A Circuit Range/Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P007100

No Sub Type Information

Ambient air temp sensor or boost temp sensor faulty Ambient air temp sensor or Boost temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Ambient air temp sensor or Boost temp sensor

Ambient Air Temperature Sensor Range/Performance

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P203F00

No Sub Type Information

No urea dosing

Urea symbol in cluster

Tank almost empty, stop dosing to maintain cooling ECM interpretation  of raw value. Urea level. DST problem.

Diagnostic Service 14. No additional action is needed

Check:

ECM interpretation  of raw value. Urea level. DST problem.

Reductant Level Low

————————————————————————————————————————————————————————————

P205A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank temp sensor Cables

Connectors

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor

————————————————————————————————————————————————————————————

P208064

Signal Plausibility Failure

None

The sensor is not plausible Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220013

Measured voltage outside the limits specified by the sensor

Circuit Open

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220164

Signal Plausibility Failure

Excessive urea dosing (only for SCR system)

Exhaust system leakage Air intake leakage

Nox-sensor

Dosing system (only for SCR system)

Exhaust system Air intake system

Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Dosing system (only for SCR system) Exhaust system

Air intake system Nox-sensor

NOx Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P061600

Measured voltage

below limit

No Sub Type

Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage above limit

No Sub Type Information

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal

Temperature Sensor Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

P20EE00

No Sub Type Information

NOx-conversion reduced by appr. 50%

Possible ammonia smell

Regent out of specification, Dosing performance low Urea specification

Dosing system

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system

SCR NOx Catalyst Efficiency Below Threshold (Bank 1)

————————————————————————————————————————————————————————————

P260013

Measured voltage outside the limits specified by the sensor

Circuit Open

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit/Open

————————————————————————————————————————————————————————————

P260200

Measured voltage below limit

No Sub Type Information

Pump always runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit Low

————————————————————————————————————————————————————————————

P260300

Measured voltage above limit

No Sub Type Information

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit High

————————————————————————————————————————————————————————————

P261087

Missing Message

Timestamps from Cluster not available

J1708 time data failure and J1939 message does not exist. (Cluster error).

Cluster

Diagnostic Service 14. No additional action is needed

Check: Cluster

ECM/PCM Internal Engine Off Timer Performance

————————————————————————————————————————————————————————————

P2BA700

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Empty Reagent Tank

————————————————————————————————————————————————————————————

P023400

No Sub Type Information

Too high pressure Turbine , Compressor

Diagnostic Service 14. No additional action is needed

Check:

Turbine , Compressor

Turbocharger/Supercharg er Overboost Condition

————————————————————————————————————————————————————————————

P029900

No Sub Type Information

Too low pressure

Boost leakage, wastegate, VGT, compressor.

Diagnostic Service 14. No additional action is needed

Check:

Boost leakage, wastegate, VGT, compressor.

Turbocharger/Supercharg er Underboost

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the sensor

General Electrical Failure

Possible damage on EMS system components depending on the high voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software Software download

application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P007087

Missing Message

None

J1708 and CAN ambient air temperature message does not exist.

Harness. Cluster

Diagnostic Service 14. No additional action is needed

Check:

Harness. Cluster

Ambient Air Temperature Sensor “A”

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is

detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P047013

Measured voltage outside the limits specified by the sensor

Circuit Open

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Exhaust Pressure Sensor “A”

————————————————————————————————————————————————————————————

P047164

Signal Plausibility Failure

Open loop control enabled. Decreased brake power.

sensor, Closed loop butterfly,  AVU sensor, butterfly, AVU

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly, AVU

Engine Exhaust Back Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P047300

Measured voltage above limit

No Sub Type Information

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Engine Exhaust Back Pressure Circuit High

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

————————————————————————————————————————————————————————————

P051B64

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The crank case pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Engine High Resolution Crankcase Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage

below limit

No Sub Type

Information

Will give water in fuel

indication.

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Water In Fuel Indicator

Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Level Circuit Low

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

P20BF00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 2 Short Circuit Low

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P109000

No Sub Type Information

Display of the message, without bip, simultaneously with the gear engaged pictogram

Driver started at too high gear at start

Protective alert for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective alert for clutch/transmission

Transmission High Gear At Start

————————————————————————————————————————————————————————————

P208E00

No Sub Type Information

No urea dosing

Sensor/Harness dosing valve

injector, clogged hoses

Diagnostic Service 14. No additional action is needed

Check:

dosing valve

injector, clogged hoses

Aftertreatment Reagent Dosing Valve Clogged

————————————————————————————————————————————————————————————

P109541

General Checksum Failure

Engine derate

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Control Unit

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or always activated if fault is

intermittent.

Broken actuator, wire or ECM driver output

Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P220E93

No Operation

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Heater Control Circuit Range/Performance (Bank

1 Sensor 1)

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P220300

No Sub Type Information

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Circuit High Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P2BA800

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Interruption of Reagent Dosing Activity

————————————————————————————————————————————————————————————

P2BA900

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality

————————————————————————————————————————————————————————————

P2BAA00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Low Reagent Consumption

————————————————————————————————————————————————————————————

P2BAD00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown

————————————————————————————————————————————————————————————

P2BAE96

Component Internal Failure

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P100629

Signal invalid

None

The boost temperature sensor output is showing constant value.

Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Intake Air Temperature Sensor 1 Stuck Bank 1

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

U010E00

Lost communication with the node

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With

Reductant Control Module

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P204A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Reductant Pressure Sensor

————————————————————————————————————————————————————————————

P203D00

Measured voltage above limit

No Sub Type Information

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Aftertreatment Reagent Level  Short Circuit High

————————————————————————————————————————————————————————————

P208A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Reductant Pump “A” Control

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P20B300

Measured voltage below limit

No Sub Type Information

None

.

Diagnostic Service 14. No additional action is needed

.

Reductant Heater Coolant Control Valve Circuit Low

————————————————————————————————————————————————————————————

P204800

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: DCU ACM Pump module: internal cabling

ACM Pump module: DCU,

ACM Pump module: internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: DCU, ACM Pump module: internal cabling

Aftertreatment Reagent Dosing Valve Short Circuit Low

————————————————————————————————————————————————————————————

P204713

Measured voltage outside the limits specified by the sensor

Circuit Open

no urea dosing

Cable / Connectors

ACM Dosing module: Dosing valve

Cable / Connectors ACM Dosing module: Dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Cable / Connectors ACM Dosing module: Dosing valve

Reductant Injection Valve Control Bank 1 Unit 1

————————————————————————————————————————————————————————————

P20C300

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 3 Short

Circuit Low

————————————————————————————————————————————————————————————

P20BB00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 1 Short

Circuit Low

————————————————————————————————————————————————————————————

P20A200

Measured voltage below limit

No Sub Type Information

Not possible to perform afterrun

Internal electrical failure in valve within the ACM

Diagnostic Service 14. No additional action is needed

Check:

Internal electrical failure in valve within the ACM

Aftertreatment Reagent Direction Valve Short

Circuit Low

————————————————————————————————————————————————————————————

P065900

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit

High

————————————————————————————————————————————————————————————

P065800

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit Low

————————————————————————————————————————————————————————————

P208D00

Measured voltage above limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent

Pump Control Short Circut High

————————————————————————————————————————————————————————————

P208C00

Measured voltage below limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short

Circuit Low

————————————————————————————————————————————————————————————

P203A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Reductant Level Sensor “A”

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P024313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Powerloss

Broken actuator or wire. Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Turbocharger/Supercharg er Wastegate Solenoid “A”

————————————————————————————————————————————————————————————

P024471

Actuator Stuck

Possible turbo damage

Wategate mechanically damaged

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate  Stuck Close

————————————————————————————————————————————————————————————

P024500

Measured voltage below limit

No Sub Type Information

Broken actuator, wire or ECM driver output

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit Low

————————————————————————————————————————————————————————————

P024600

Measured voltage above limit

No Sub Type Information

Powerloss

Broken actuator, wire or ECM driver output

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

P204300

No Sub Type Information

None

Urea tank temp sensor stuck high

Urea tank temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor

Aftertreatment Reagent Tank Temperature Sensor Stuck

————————————————————————————————————————————————————————————

P209F73

Actuator Stuck Closed

None

Urea tank temp sensor or Urea tank heating system Urea tank temp sensor, Urea tank heating system

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Urea tank heating system

Aftertreatment Reagent Tank Temperature

————————————————————————————————————————————————————————————

P20F400

No Sub Type Information

Too low urea consumption

Urea level sensor stuck Clogged urea system Wrong urea tank Wrong dosing module Nozzle or

ACM Dosing module: dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Nozzle or

ACM Dosing module: dosing valve

AdBlue Consumption Too Low

————————————————————————————————————————————————————————————

U029D00

Lost communication with the node

No Sub Type Information

MS from Nox-sensor ECU Nox-sensor power supply CAN communication between ECM and Nox-EUC

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor power supply

CAN communication between ECM and Nox-EUC

Lost Communication With NOx Sensor “A”

————————————————————————————————————————————————————————————

P204C00

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Aftertreatment Reagent Pressure Sensor Circuit Low

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P220A1C

Circuit Voltage Out of Range

Too high voltage to NOx- sensor ECU

Battery voltage

Diagnostic Service 14. No additional action is needed

Check:

Battery voltage

NOx Sensor Supply Voltage Circuit (Bank 1

Sensor 1)

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake

(VCB) Control Oil Temperature Too Low

————————————————————————————————————————————————————————————

P113700

DUMMY fault. Not intented for fault

tracing

No Sub Type Information

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

Check:

DUMMY fault. Not intented for fault tracing

Oil Thermostat

————————————————————————————————————————————————————————————

P113711

Measured voltage below limit

Circuit Short To Ground

Oil thermostat alwaysclosed.

Broken actuator, wire or

ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P113712

Measured voltage above limit

Circuit Short To Battery

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P113713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P011164

Signal Plausibility Failure

None

The boost temperature sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Ambient air temperature sensor.

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Ambient air temperature sensor.

Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1

————————————————————————————————————————————————————————————

P20E892

Performance or Incorrect Operation

No urea dosing

ACM dosing module: Dosing valve leakage.

Bleed orifice leakage, pressure hose lekage, pump internal leakage, empty ureatank

Tank frozen.

if pump/tank-lines are mixed-up when connecting them to the pump unit there will be no pressure built (check color mar Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Diagnostic Service 14. No additional action is needed

Check:

Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Reductant Pressure Too Low

————————————————————————————————————————————————————————————

P21CA00

No Sub Type Information

No dozing

Voltage supply to ACM. Voltage supply to Urea pump.

Diagnostic Service 14. No additional action is needed

Check:

Voltage supply to Urea pump.

Reductant Control Module Supply Voltage

————————————————————————————————————————————————————————————

P114411

Measured voltage below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage

above limit

Circuit Short To Battery

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P116A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side

————————————————————————————————————————————————————————————

P116B00

Measured voltage below limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit

Low

————————————————————————————————————————————————————————————

P116C00

Measured voltage above limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A”

Control Low Side Circuit High

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P115C00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “C” Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P115D00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “C” Circuit Low

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P115E97

Component or System Operation Obstructed or Blocked

No dozing

Bleed orifice clogged

Bleed orifice, Urea pressure sensor,

Diagnostic Service 14. No additional action is needed

Check:

Bleed orifice, Urea pressure sensor,

Reductant Return No Flow Detected

————————————————————————————————————————————————————————————

P11609B

High/Excessive Flow

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown (First Level)

————————————————————————————————————————————————————————————

P116192

Performance or Incorrect Operation

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality (First Level)

————————————————————————————————————————————————————————————

P116300

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System (First Level)

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P115600

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “A” Circuit High

————————————————————————————————————————————————————————————

P115700

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “A” Circuit Low

————————————————————————————————————————————————————————————

P115800

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power Supply “B” Circuit High

————————————————————————————————————————————————————————————

P115900

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power Supply “B” Circuit Low

————————————————————————————————————————————————————————————

P115A00

No Sub Type Information

Possible incread risk of crystalization

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Exhaust Gas Temperature Sensor Circuit Signal Compare Failure Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P115B00

No Sub Type Information

None

The sensor is stuck Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Stuck Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P116441

General Checksum Failure

All ACM functionality disabled, no urea dosing

No software in ACM

.

Diagnostic Service 14. No additional action is needed

Check:

No software in ACM

Reductant Control Module Internal Control Module Memory Checksum Error

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P116500

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at low speed but still shifts to high gear, range high.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too High Gear

————————————————————————————————————————————————————————————

P116600

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at high speed but still down-shift to low gear, range low.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too Low Gear

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

P24FF00

No Sub Type Information

If tank temp is too high, no urea dosing

Urea tank temp is too high Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Reductant Temperature Too High

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P117A00

No Sub Type Information

Possible ammonia smell

SCR catalyst removed, Regent out of specification, Clogged dosing system Urea specification

Dosing system Catalyst deactivated

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system Catalyst deactivated

SCR NOx Catalyst Efficiency Critically Below Threshold Bank 1

————————————————————————————————————————————————————————————

P047800

Measured voltage

above limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P222764

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The ambient air pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Sensor “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P205E1F

Circuit Intermittent

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor Circuit

Intermittent/Erratic

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P25AB00

Measured voltage

above limit

No Sub Type

Information

Possible black smoke during

start.

Harness/Broken actuator

Harness/Valve

Diagnostic Service 14. No additional

action is needed

Check:

Harness/Valve

Piston Cooling Oil Control

Circuit High

————————————————————————————————————————————————————————————

P25AA00

Measured voltage below limit

No Sub Type Information

No piston cooling=>major engine damage if high

loads.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control Circuit Low

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P010662

Signal Compare Failure

Powerloss Black smoke

The boost pressure sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P25AE00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Piston Cooling Oil

Pressure Too Low

————————————————————————————————————————————————————————————

P25A900

DUMMY fault. Not intented for fault tracing

No Sub Type Information

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

Check:

DUMMY fault. Not intented for fault tracing

Piston Cooling Oil Control

————————————————————————————————————————————————————————————

P25A913

Measured voltage outside the limits specified by the sensor

Circuit Open

Possible black smoke during start.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P225D00

No Sub Type Information

None except fault code and lamp

Sensor removed (measures surround air)

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Signal Stuck Low Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

————————————————————————————————————————————————————————————

P22FB00

No Sub Type Information

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Sensing Element Bank 1 Sensor 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P110F90

Stuck On

Stop switch can not be

activated

Switch

Engine stop switch

Diagnostic Service 14. No additional

action is needed

Check:

Engine stop switch

Engine Stop Switch Stuck

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P055A00

DUMMY fault. Not intented for fault

tracing

No Sub Type Information

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

Check:

DUMMY fault. Not intented for fault tracing

Engine Oil Pressure Sensor/Switch “B”

————————————————————————————————————————————————————————————

P055A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

.

Diagnostic Service 14. No additional action is needed

.

Engine Oil Pressure Sensor/Switch “B”

————————————————————————————————————————————————————————————

P055B64

Signal Plausibility Failure

The control function closes the PCJ valve. When the fault is set, the PCJ oil pressure is forced to max (if calibrated so in the pcj_ function).

The sensor is stuck, has an offset or another kind of rationality fault. It could also be the valve that cannot be closed.

Sensor/Valve

Diagnostic Service 14. No additional action is needed

Check: Sensor/Valve

Piston Cooling Oil Pressure Sensor Range/Performance

————————————————————————————————————————————————————————————

P055D00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P112800

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Moderately Low

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute

Pressure Moderately Too High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Engine Coolant Level

Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit High

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

P047F71

Actuator Stuck

Decreased brake power.

sensor, Closed loop butterfly

sensor, butterfly

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly

Exhaust Pressure Control Valve “A” Stuck Open

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Camshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the

sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct

Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P007100

No Sub Type Information

Ambient air temp sensor or boost temp sensor faulty Ambient air temp sensor or Boost temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Ambient air temp sensor or Boost temp sensor

Ambient Air Temperature Sensor Range/Performance

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P203F00

No Sub Type Information

No urea dosing

Urea symbol in cluster

Tank almost empty, stop dosing to maintain cooling ECM interpretation  of raw value. Urea level. DST problem.

Diagnostic Service 14. No additional action is needed

Check:

ECM interpretation  of raw value. Urea level. DST problem.

Reductant Level Low

————————————————————————————————————————————————————————————

P205A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank temp sensor Cables

Connectors

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor

————————————————————————————————————————————————————————————

P208064

Signal Plausibility Failure

None

The sensor is not plausible Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P220013

Measured voltage outside the limits specified by the sensor

Circuit Open

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220164

Signal Plausibility Failure

Excessive urea dosing (only for SCR system)

Exhaust system leakage Air intake leakage

Nox-sensor

Dosing system (only for SCR system)

Exhaust system Air intake system

Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Dosing system (only for SCR system) Exhaust system

Air intake system Nox-sensor

NOx Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the

sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

————————————————————————————————————————————————————————————

P061600

Measured voltage below limit

No Sub Type Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage

above limit

No Sub Type

Information

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal Temperature Sensor

Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

P20EE00

No Sub Type Information

NOx-conversion reduced by appr. 50%

Possible ammonia smell

Regent out of specification, Dosing performance low Urea specification

Dosing system

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system

SCR NOx Catalyst Efficiency Below Threshold (Bank 1)

————————————————————————————————————————————————————————————

P260013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit/Open

————————————————————————————————————————————————————————————

P260200

Measured voltage below limit

No Sub Type Information

Pump always runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit Low

————————————————————————————————————————————————————————————

P260300

Measured voltage above limit

No Sub Type Information

Pump always at half speed. High coolant temperatures may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Coolant Pump Control Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P261087

Missing Message

Timestamps from Cluster not available

J1708 time data failure and J1939 message does not exist. (Cluster error).

Cluster

Diagnostic Service 14. No additional action is needed

Check: Cluster

ECM/PCM Internal Engine Off Timer Performance

————————————————————————————————————————————————————————————

P2BA700

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Empty Reagent Tank

————————————————————————————————————————————————————————————

P023400

No Sub Type Information

Too high pressure Turbine , Compressor

Diagnostic Service 14. No additional action is needed

Check:

Turbine , Compressor

Turbocharger/Supercharg er Overboost Condition

————————————————————————————————————————————————————————————

P029900

No Sub Type Information

Too low pressure

Boost leakage, wastegate, VGT, compressor.

Diagnostic Service 14. No additional action is needed

Check:

Boost leakage, wastegate, VGT, compressor.

Turbocharger/Supercharg er Underboost

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the sensor

General Electrical Failure

Possible damage on EMS system components depending on the high voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software Software download

application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

————————————————————————————————————————————————————————————

P007087

Missing Message

None

J1708 and CAN ambient air temperature message does not exist.

Harness. Cluster

Diagnostic Service 14. No additional action is needed

Check:

Harness. Cluster

Ambient Air Temperature Sensor “A”

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is

detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P047013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Exhaust Pressure Sensor “A”

————————————————————————————————————————————————————————————

P047164

Signal Plausibility Failure

Open loop control enabled. Decreased brake power.

sensor, Closed loop butterfly,  AVU sensor, butterfly, AVU

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly, AVU

Engine Exhaust Back Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P047300

Measured voltage above limit

No Sub Type Information

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Engine Exhaust Back Pressure Circuit High

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P051B64

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The crank case pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Engine High Resolution Crankcase Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check:

Sensor ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage

below limit

No Sub Type

Information

Will give water in fuel

indication.

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Water In Fuel Indicator

Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Engine Oil Level Circuit Low

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

P20BF00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 2 Short Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P109000

No Sub Type Information

Display of the message, without bip, simultaneously with the gear engaged

pictogram

Driver started at too high gear at start

Protective alert for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective alert for clutch/transmission

Transmission High Gear At Start

————————————————————————————————————————————————————————————

P208E00

No Sub Type Information

No urea dosing

Sensor/Harness dosing valve

injector, clogged hoses

Diagnostic Service 14. No additional action is needed

Check:

dosing valve

injector, clogged hoses

Aftertreatment Reagent Dosing Valve Clogged

————————————————————————————————————————————————————————————

P109541

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Aftertreatment Control

Unit

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or always activated if fault is intermittent.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P220E93

No Operation

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Heater Control Circuit Range/Performance (Bank

1 Sensor 1)

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P220300

No Sub Type Information

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Circuit High Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P2BA800

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Interruption of Reagent Dosing Activity

————————————————————————————————————————————————————————————

P2BA900

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P2BAA00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Low Reagent Consumption

————————————————————————————————————————————————————————————

P2BAD00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown

————————————————————————————————————————————————————————————

P2BAE96

Component Internal Failure

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn

off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100629

Signal invalid

None

The boost temperature sensor output is showing constant value.

Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Intake Air Temperature Sensor 1 Stuck Bank 1

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

U010E00

Lost communication with the node

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Reductant Control

Module

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P204A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Reductant Pressure Sensor

————————————————————————————————————————————————————————————

P203D00

Measured voltage above limit

No Sub Type Information

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Aftertreatment Reagent Level  Short Circuit High

————————————————————————————————————————————————————————————

P208A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Reductant Pump “A” Control

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P20B300

Measured voltage below limit

No Sub Type Information

None

.

Diagnostic Service 14. No additional action is needed

.

Reductant Heater Coolant Control Valve Circuit Low

————————————————————————————————————————————————————————————

P204800

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: DCU ACM Pump module: internal cabling

ACM Pump module: DCU,

ACM Pump module: internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: DCU, ACM Pump module: internal cabling

Aftertreatment Reagent Dosing Valve Short Circuit Low

————————————————————————————————————————————————————————————

P204713

Measured voltage outside the limits specified by the sensor

Circuit Open

no urea dosing

Cable / Connectors

ACM Dosing module: Dosing valve

Cable / Connectors ACM Dosing module: Dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Cable / Connectors ACM Dosing module: Dosing valve

Reductant Injection Valve Control Bank 1 Unit 1

————————————————————————————————————————————————————————————

P20C300

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 3 Short

Circuit Low

————————————————————————————————————————————————————————————

P20BB00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 1 Short

Circuit Low

————————————————————————————————————————————————————————————

P20A200

Measured voltage below limit

No Sub Type Information

Not possible to perform afterrun

Internal electrical failure in valve within the ACM

Diagnostic Service 14. No additional action is needed

Check:

Internal electrical failure in valve within the ACM

Aftertreatment Reagent Direction Valve Short

Circuit Low

————————————————————————————————————————————————————————————

P065900

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit

High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P065800

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit Low

————————————————————————————————————————————————————————————

P208D00

Measured voltage above limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent

Pump Control Short Circut High

————————————————————————————————————————————————————————————

P208C00

Measured voltage below limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short

Circuit Low

————————————————————————————————————————————————————————————

P203A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Reductant Level Sensor “A”

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P024313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Powerloss

Broken actuator or wire. Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Turbocharger/Supercharg er Wastegate Solenoid “A”

————————————————————————————————————————————————————————————

P024471

Actuator Stuck

Possible turbo damage

Wategate mechanically damaged

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate  Stuck Close

————————————————————————————————————————————————————————————

P024500

Measured voltage below limit

No Sub Type Information

Broken actuator, wire or

ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit Low

————————————————————————————————————————————————————————————

P024600

Measured voltage above limit

No Sub Type Information

Powerloss

Broken actuator, wire or ECM driver output

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit High

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

P204300

No Sub Type Information

None

Urea tank temp sensor stuck high

Urea tank temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor

Aftertreatment Reagent Tank Temperature Sensor Stuck

————————————————————————————————————————————————————————————

P209F73

Actuator Stuck Closed

None

Urea tank temp sensor or Urea tank heating system Urea tank temp sensor, Urea tank heating system

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Urea tank heating system

Aftertreatment Reagent Tank Temperature

————————————————————————————————————————————————————————————

P20F400

No Sub Type Information

Too low urea consumption

Urea level sensor stuck Clogged urea system Wrong urea tank Wrong dosing module Nozzle or

ACM Dosing module: dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Nozzle or

ACM Dosing module: dosing valve

AdBlue Consumption Too Low

————————————————————————————————————————————————————————————

U029D00

Lost communication with the node

No Sub Type Information

MS from Nox-sensor ECU Nox-sensor power supply CAN communication between ECM and Nox-EUC

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor power supply

CAN communication between ECM and Nox-EUC

Lost Communication With NOx Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P204C00

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Aftertreatment Reagent Pressure Sensor Circuit Low

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P220A1C

Circuit Voltage Out of Range

Too high voltage to NOx- sensor ECU

Battery voltage

Diagnostic Service 14. No additional action is needed

Check:

Battery voltage

NOx Sensor Supply Voltage Circuit (Bank 1

Sensor 1)

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil

Temperature Too Low

————————————————————————————————————————————————————————————

P113700

DUMMY fault. Not intented for fault

tracing

No Sub Type Information

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

Check:

DUMMY fault. Not intented for fault tracing

Oil Thermostat

————————————————————————————————————————————————————————————

P113711

Measured voltage below limit

Circuit Short To Ground

Oil thermostat alwaysclosed.

Broken actuator, wire or

ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P113712

Measured voltage above limit

Circuit Short To Battery

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P113713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil thermostat always open. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Oil Thermostat

————————————————————————————————————————————————————————————

P011164

Signal Plausibility Failure

None

The boost temperature sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Ambient air temperature sensor.

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Ambient air temperature sensor.

Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P20E892

Performance or Incorrect Operation

No urea dosing

ACM dosing module: Dosing valve leakage.

Bleed orifice leakage, pressure hose lekage, pump internal leakage, empty ureatank

Tank frozen.

if pump/tank-lines are mixed-up when connecting them to the pump unit there will be no pressure built (check color mar Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Diagnostic Service 14. No additional action is needed

Check:

Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Reductant Pressure Too Low

————————————————————————————————————————————————————————————

P21CA00

No Sub Type Information

No dozing

Voltage supply to ACM.

Voltage supply to Urea pump.

Diagnostic Service 14. No additional action is needed

Check:

Voltage supply to Urea pump.

Reductant Control Module Supply Voltage

————————————————————————————————————————————————————————————

P114411

Measured voltage below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage

above limit

Circuit Short To Battery

Impossible to activate

starter motor.

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P116A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side

————————————————————————————————————————————————————————————

P116B00

Measured voltage below limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit

Low

————————————————————————————————————————————————————————————

P116C00

Measured voltage above limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit

High

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P115C00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control

Module Sensor Power Supply “C” Circuit High

————————————————————————————————————————————————————————————

P115D00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “C” Circuit Low

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P115E97

Component or System Operation Obstructed or Blocked

No dozing

Bleed orifice clogged

Bleed orifice, Urea pressure sensor,

Diagnostic Service 14. No additional action is needed

Check:

Bleed orifice, Urea pressure sensor,

Reductant Return No Flow Detected

————————————————————————————————————————————————————————————

P11609B

High/Excessive Flow

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown (First Level)

————————————————————————————————————————————————————————————

P116192

Performance or Incorrect Operation

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality (First Level)

————————————————————————————————————————————————————————————

P116300

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System (First Level)

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P115600

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “A” Circuit High

————————————————————————————————————————————————————————————

P115700

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power Supply “A” Circuit Low

————————————————————————————————————————————————————————————

P115800

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power Supply “B” Circuit High

————————————————————————————————————————————————————————————

P115900

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power Supply “B” Circuit Low

————————————————————————————————————————————————————————————

P115A00

No Sub Type Information

Possible incread risk of crystalization

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Exhaust Gas Temperature Sensor Circuit Signal Compare Failure Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P115B00

No Sub Type Information

None

The sensor is stuck Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Stuck Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P116441

General Checksum Failure

All ACM functionality disabled, no urea dosing

No software in ACM

.

Diagnostic Service 14. No additional action is needed

Check:

No software in ACM

Reductant Control Module Internal Control Module Memory Checksum Error

————————————————————————————————————————————————————————————

P116500

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at low speed but still shifts to high gear, range high.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too High Gear

————————————————————————————————————————————————————————————

P116600

No Sub Type Information

Buzzer signal (alert), Display of the message, with bip, simultaneously with the gear engaged pictogram.

Driver is at high speed but still down-shift to low gear, range low.

Protective measure for

clutch/transmission

Diagnostic Service 14. No additional action is needed

Check:

Protective measure for clutch/transmission

Driver Selected Too Low Gear

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

P24FF00

No Sub Type Information

If tank temp is too high, no urea dosing

Urea tank temp is too high Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Reductant Temperature Too High

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P117A00

No Sub Type Information

Possible ammonia smell

SCR catalyst removed, Regent out of specification, Clogged dosing system Urea specification

Dosing system Catalyst deactivated

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system Catalyst deactivated

SCR NOx Catalyst Efficiency Critically Below Threshold Bank 1

————————————————————————————————————————————————————————————

P047800

Measured voltage above limit

No Sub Type Information

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P222764

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The ambient air pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Sensor “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P205E1F

Circuit Intermittent

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor Circuit

Intermittent/Erratic

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P25AB00

Measured voltage

above limit

No Sub Type

Information

Possible black smoke during

start.

Harness/Broken actuator

Harness/Valve

Diagnostic Service 14. No additional

action is needed

Check:

Harness/Valve

Piston Cooling Oil Control

Circuit High

————————————————————————————————————————————————————————————

P25AA00

Measured voltage below limit

No Sub Type Information

No piston cooling=>major engine damage if high

loads.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P010662

Signal Compare Failure

Powerloss Black smoke

The boost pressure sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P25AE00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Piston Cooling Oil

Pressure Too Low

————————————————————————————————————————————————————————————

P25A900

DUMMY fault. Not intented for fault tracing

No Sub Type Information

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

Check:

DUMMY fault. Not intented for fault tracing

Piston Cooling Oil Control

————————————————————————————————————————————————————————————

P25A913

Measured voltage outside the limits specified by the sensor

Circuit Open

Possible black smoke during start.

Harness/Broken actuator Harness/Valve

Diagnostic Service 14. No additional action is needed

Check: Harness/Valve

Piston Cooling Oil Control

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P225D00

No Sub Type Information

None except fault code and lamp

Sensor removed (measures surround air)

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Signal Stuck Low Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

————————————————————————————————————————————————————————————

P22FB00

No Sub Type Information

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Sensing Element Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P110F90

Stuck On

Stop switch can not be

activated

Switch

Engine stop switch

Diagnostic Service 14. No additional

action is needed

Check:

Engine stop switch

Engine Stop Switch Stuck

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P055A00

DUMMY fault. Not

intented for fault tracing

No Sub Type Information

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

DUMMY fault. Not intented for fault tracing

Check:

DUMMY fault. Not intented for fault tracing

Engine Oil Pressure Sensor/Switch “B”

————————————————————————————————————————————————————————————

P055A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

.

Diagnostic Service 14. No additional action is needed

.

Engine Oil Pressure Sensor/Switch “B”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P055B64

Signal Plausibility Failure

The control function closes the PCJ valve. When the fault is set, the PCJ oil pressure is forced to max (if calibrated so in the pcj_ function).

The sensor is stuck, has an offset or another kind of rationality fault. It could also be the valve that cannot be closed.

Sensor/Valve

Diagnostic Service 14. No additional action is needed

Check: Sensor/Valve

Piston Cooling Oil Pressure Sensor Range/Performance

————————————————————————————————————————————————————————————

P055D00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil

Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P112800

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Piston Cooling Oil Pressure Moderately Low

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Moderately Too

High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Engine Coolant Level

Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Low Pressure Fuel System Sensor Circuit High

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

P047F71

Actuator Stuck

Decreased brake power.

sensor, Closed loop butterfly

sensor, butterfly

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly

Exhaust Pressure Control Valve “A” Stuck Open

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Camshaft Position Sensor A Circuit Range/Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P007100

No Sub Type Information

Ambient air temp sensor or boost temp sensor faulty Ambient air temp sensor or Boost temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Ambient air temp sensor or Boost temp sensor

Ambient Air Temperature Sensor Range/Performance

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P203F00

No Sub Type Information

No urea dosing

Urea symbol in cluster

Tank almost empty, stop dosing to maintain cooling ECM interpretation  of raw value. Urea level. DST problem.

Diagnostic Service 14. No additional action is needed

Check:

ECM interpretation  of raw value. Urea level. DST problem.

Reductant Level Low

————————————————————————————————————————————————————————————

P205A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank temp sensor Cables

Connectors

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor

————————————————————————————————————————————————————————————

P208064

Signal Plausibility Failure

None

The sensor is not plausible Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220013

Measured voltage outside the limits specified by the sensor

Circuit Open

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220164

Signal Plausibility Failure

Excessive urea dosing (only for SCR system)

Exhaust system leakage Air intake leakage

Nox-sensor

Dosing system (only for SCR system)

Exhaust system Air intake system

Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Dosing system (only for SCR system) Exhaust system

Air intake system Nox-sensor

NOx Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P061600

Measured voltage

below limit

No Sub Type

Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage above limit

No Sub Type Information

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal

Temperature Sensor Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

P20EE00

No Sub Type Information

NOx-conversion reduced by appr. 50%

Possible ammonia smell

Regent out of specification, Dosing performance low Urea specification

Dosing system

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system

SCR NOx Catalyst Efficiency Below Threshold (Bank 1)

————————————————————————————————————————————————————————————

P261087

Missing Message

Timestamps from Cluster not available

J1708 time data failure and J1939 message does not exist. (Cluster error).

Cluster

Diagnostic Service 14. No additional action is needed

Check: Cluster

ECM/PCM Internal Engine Off Timer Performance

————————————————————————————————————————————————————————————

P2BA700

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Empty Reagent Tank

————————————————————————————————————————————————————————————

P023400

No Sub Type Information

Too high pressure Turbine , Compressor

Diagnostic Service 14. No additional action is needed

Check:

Turbine , Compressor

Turbocharger/Supercharg er Overboost Condition

————————————————————————————————————————————————————————————

P029900

No Sub Type Information

Too low pressure

Boost leakage, wastegate, VGT, compressor.

Diagnostic Service 14. No additional action is needed

Check:

Boost leakage, wastegate, VGT, compressor.

Turbocharger/Supercharg er Underboost

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the

sensor

General Electrical Failure

Possible damage on EMS system components depending on the high

voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software

Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

————————————————————————————————————————————————————————————

P007087

Missing Message

None

J1708 and CAN ambient air temperature message does not exist.

Harness. Cluster

Diagnostic Service 14. No additional action is needed

Check:

Harness. Cluster

Ambient Air Temperature Sensor “A”

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is

detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P047013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Exhaust Pressure Sensor “A”

————————————————————————————————————————————————————————————

P047164

Signal Plausibility Failure

Open loop control enabled. Decreased brake power.

sensor, Closed loop

butterfly,  AVU sensor, butterfly, AVU

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly, AVU

Engine Exhaust Back

Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P047300

Measured voltage above limit

No Sub Type Information

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Engine Exhaust Back Pressure Circuit High

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

————————————————————————————————————————————————————————————

P051B64

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The crank case pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Engine High Resolution Crankcase Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check:

Sensor ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage below limit

No Sub Type Information

Will give water in fuel indication.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Level Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

P20BF00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 2 Short Circuit Low

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P208E00

No Sub Type Information

No urea dosing

Sensor/Harness dosing valve

injector, clogged hoses

Diagnostic Service 14. No additional action is needed

Check:

dosing valve

injector, clogged hoses

Aftertreatment Reagent Dosing Valve Clogged

————————————————————————————————————————————————————————————

P109541

General Checksum Failure

Engine derate

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Control Unit

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or

always activated if fault is intermittent.

Broken actuator, wire or

ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P220E93

No Operation

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Heater Control Circuit Range/Performance (Bank 1 Sensor 1)

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P220300

No Sub Type Information

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Circuit High Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P2BA800

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Interruption of Reagent Dosing Activity

————————————————————————————————————————————————————————————

P2BA900

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality

————————————————————————————————————————————————————————————

P2BAA00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Low Reagent Consumption

————————————————————————————————————————————————————————————

P2BAD00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown

————————————————————————————————————————————————————————————

P2BAE96

Component Internal Failure

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn

off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100629

Signal invalid

None

The boost temperature sensor output is showing constant value.

Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Intake Air Temperature Sensor 1 Stuck Bank 1

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

U010E00

Lost communication with the node

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Reductant Control

Module

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P204A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Reductant Pressure Sensor

————————————————————————————————————————————————————————————

P203D00

Measured voltage above limit

No Sub Type Information

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Aftertreatment Reagent Level  Short Circuit High

————————————————————————————————————————————————————————————

P208A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Reductant Pump “A” Control

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P20B300

Measured voltage below limit

No Sub Type Information

None

.

Diagnostic Service 14. No additional action is needed

.

Reductant Heater Coolant Control Valve Circuit Low

————————————————————————————————————————————————————————————

P204800

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: DCU ACM Pump module: internal cabling

ACM Pump module: DCU,

ACM Pump module: internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: DCU, ACM Pump module: internal cabling

Aftertreatment Reagent Dosing Valve Short Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P204713

Measured voltage outside the limits specified by the sensor

Circuit Open

no urea dosing

Cable / Connectors

ACM Dosing module: Dosing valve

Cable / Connectors ACM Dosing module: Dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Cable / Connectors ACM Dosing module: Dosing valve

Reductant Injection Valve Control Bank 1 Unit 1

————————————————————————————————————————————————————————————

P20C300

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 3 Short Circuit Low

————————————————————————————————————————————————————————————

P20BB00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 1 Short Circuit Low

————————————————————————————————————————————————————————————

P20A200

Measured voltage below limit

No Sub Type Information

Not possible to perform afterrun

Internal electrical failure in valve within the ACM

Diagnostic Service 14. No additional action is needed

Check:

Internal electrical failure in valve within the ACM

Aftertreatment Reagent Direction Valve Short Circuit Low

————————————————————————————————————————————————————————————

P065900

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit High

————————————————————————————————————————————————————————————

P065800

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit Low

————————————————————————————————————————————————————————————

P208D00

Measured voltage above limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short Circut High

————————————————————————————————————————————————————————————

P208C00

Measured voltage below limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short Circuit Low

————————————————————————————————————————————————————————————

P203A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Reductant Level Sensor “A”

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P024313

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Broken actuator or wire. Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Turbocharger/Supercharg er Wastegate Solenoid “A”

————————————————————————————————————————————————————————————

P024471

Actuator Stuck

Possible turbo damage

Wategate mechanically damaged

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate  Stuck Close

————————————————————————————————————————————————————————————

P024500

Measured voltage below limit

No Sub Type Information

Broken actuator, wire or ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit Low

————————————————————————————————————————————————————————————

P024600

Measured voltage above limit

No Sub Type Information

Powerloss

Broken actuator, wire or ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit High

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

P204300

No Sub Type Information

None

Urea tank temp sensor stuck high

Urea tank temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor

Aftertreatment Reagent Tank Temperature Sensor Stuck

————————————————————————————————————————————————————————————

P209F73

Actuator Stuck Closed

None

Urea tank temp sensor or Urea tank heating system Urea tank temp sensor, Urea tank heating system

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Urea tank heating system

Aftertreatment Reagent Tank Temperature

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P20F400

No Sub Type Information

Too low urea consumption

Urea level sensor stuck Clogged urea system Wrong urea tank Wrong dosing module Nozzle or

ACM Dosing module: dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Nozzle or

ACM Dosing module: dosing valve

AdBlue Consumption Too Low

————————————————————————————————————————————————————————————

U029D00

Lost communication with the node

No Sub Type Information

MS from Nox-sensor ECU Nox-sensor power supply CAN communication between ECM and Nox-EUC

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor power supply

CAN communication between ECM and Nox-EUC

Lost Communication With NOx Sensor “A”

————————————————————————————————————————————————————————————

P204C00

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Aftertreatment Reagent Pressure Sensor Circuit Low

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil

Temperature Too Low

————————————————————————————————————————————————————————————

P011164

Signal Plausibility Failure

None

The boost temperature sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Ambient air temperature sensor.

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Ambient air temperature sensor.

Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1

————————————————————————————————————————————————————————————

P20E892

Performance or Incorrect Operation

No urea dosing

ACM dosing module: Dosing valve leakage.

Bleed orifice leakage, pressure hose lekage, pump internal leakage, empty ureatank

Tank frozen.

if pump/tank-lines are mixed-up when connecting them to the pump unit there will be no pressure built (check color mar Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Diagnostic Service 14. No additional action is needed

Check:

Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Reductant Pressure Too Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P21CA00

No Sub Type Information

No dozing

Voltage supply to ACM. Voltage supply to Urea

pump.

Diagnostic Service 14. No additional action is needed

Check:

Voltage supply to Urea pump.

Reductant Control Module Supply Voltage

————————————————————————————————————————————————————————————

P114411

Measured voltage

below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage above limit

Circuit Short To Battery

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P116A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side

————————————————————————————————————————————————————————————

P116B00

Measured voltage below limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit Low

————————————————————————————————————————————————————————————

P116C00

Measured voltage above limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit High

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P115211

Measured voltage below limit

Circuit Short To Ground

Priming pump permanently on. Possible damage of priming pump.

Actuator/harness Priming pump

Diagnostic Service 14. No additional action is needed

Check: Priming pump

Fuel Priming Pump

————————————————————————————————————————————————————————————

P115212

Measured voltage

above limit

Circuit Short To Battery

Priming or drain aborted

and inhibited

Actuator/harness

Priming pump

Diagnostic Service 14. No additional

action is needed

Check:

Priming pump

Fuel Priming Pump

————————————————————————————————————————————————————————————

P115213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Priming or drain inhibited

Actuator/harness Priming pump

Diagnostic Service 14. No additional action is needed

Check: Priming pump

Fuel Priming Pump

————————————————————————————————————————————————————————————

P115C00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “C” Circuit High

————————————————————————————————————————————————————————————

P115D00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control

Module Sensor Power Supply “C” Circuit Low

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P115E97

Component or System Operation Obstructed or Blocked

No dozing

Bleed orifice clogged

Bleed orifice, Urea pressure sensor,

Diagnostic Service 14. No additional action is needed

Check:

Bleed orifice, Urea pressure sensor,

Reductant Return No Flow Detected

————————————————————————————————————————————————————————————

P11609B

High/Excessive Flow

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown (First Level)

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P116192

Performance or Incorrect Operation

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality (First Level)

————————————————————————————————————————————————————————————

P116300

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System (First Level)

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P115600

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control

Module Sensor Power Supply “A” Circuit High

————————————————————————————————————————————————————————————

P115700

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “A” Circuit Low

————————————————————————————————————————————————————————————

P115800

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power

Supply “B” Circuit High

————————————————————————————————————————————————————————————

P115900

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control

Module Sensor Power Supply “B” Circuit Low

————————————————————————————————————————————————————————————

P115A00

No Sub Type Information

Possible incread risk of crystalization

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Exhaust Gas Temperature Sensor Circuit Signal Compare Failure Bank 1

Sensor 1

————————————————————————————————————————————————————————————

P115B00

No Sub Type Information

None

The sensor is stuck Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Stuck Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P116441

General Checksum Failure

All ACM functionality disabled, no urea dosing

No software in ACM

.

Diagnostic Service 14. No additional action is needed

Check:

No software in ACM

Reductant Control Module Internal Control Module Memory Checksum Error

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

P24FF00

No Sub Type Information

If tank temp is too high, no urea dosing

Urea tank temp is too high Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Reductant Temperature Too High

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional

action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P117A00

No Sub Type Information

Possible ammonia smell

SCR catalyst removed, Regent out of specification, Clogged dosing system Urea specification

Dosing system Catalyst deactivated

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system Catalyst deactivated

SCR NOx Catalyst Efficiency Critically Below Threshold Bank 1

————————————————————————————————————————————————————————————

P047800

Measured voltage above limit

No Sub Type Information

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P222764

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The ambient air pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Sensor “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P205E1F

Circuit Intermittent

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor Circuit

Intermittent/Erratic

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P010662

Signal Compare Failure

Powerloss Black smoke

The boost pressure sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P225D00

No Sub Type Information

None except fault code and lamp

Sensor removed (measures surround air)

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Signal Stuck Low Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P22FB00

No Sub Type Information

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Sensing Element Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional

action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Moderately Too

High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Engine Coolant Level

Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Low Pressure Fuel System Sensor Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

P047F71

Actuator Stuck

Decreased brake power.

sensor, Closed loop butterfly

sensor, butterfly

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly

Exhaust Pressure Control Valve “A” Stuck Open

————————————————————————————————————————————————————————————

U000188

It has not been possible to send frames on High Speed CAN Communication Bus and It has not been possible to receive frames on High Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

It has not been possible to send frames on Medium Speed CAN Communication Bus and It has not been possible to receive frames on Medium Speed CAN Communication Bus

Bus off

.

Diagnostic Service 14. No additional action is needed

.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U010187

Missing Message

ETC2 not responding

.

Diagnostic Service 14. No additional

action is needed

Check:

ETC2 not responding

Lost Communication with

TECU

————————————————————————————————————————————————————————————

P034031

No Signal

The engine start time will increase.

Possible loss of power

Sensor/Harness Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Camshaft Position Sensor “A” Bank 1 or Single Sensor

————————————————————————————————————————————————————————————

P034138

Signal Frequency Incorrect

The engine start time will increase.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Camshaft Position Sensor A Circuit Range/Performance

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P052612

Measured voltage above limit

Circuit Short To Battery

Either

1. Fan will work as on/off fan. 100% fan speed if cooling is needed. Higher fuel consumption.

Or

2. Fan will work in open loop mode. Deteriorated fan control, but might not be noticable to driver.

Broken sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Fan Speed Sensor Circuit

————————————————————————————————————————————————————————————

P054300

Measured voltage outside the limits specified by the sensor

No Sub Type Information

Might get start problems in cold climate.

Heating element or wire broken.

Preheat sense 1

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1

Intake Air Heater A Circuit Open

————————————————————————————————————————————————————————————

P001676

Wrong Mounting Position

Fuel consumption increased

Bad correlation between cam and crank, engine transmission not correct Engine transmission

Diagnostic Service 14. No additional action is needed

Check:

Engine transmission

Crankshaft Position – Camshaft Position Correlation

————————————————————————————————————————————————————————————

P007100

No Sub Type Information

Ambient air temp sensor or boost temp sensor faulty Ambient air temp sensor or Boost temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Ambient air temp sensor or Boost temp sensor

Ambient Air Temperature Sensor Range/Performance

————————————————————————————————————————————————————————————

P02CD00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 1 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02CF00

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 2 Fuel Injector Offset Learning at Max Limit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P02D100

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 3 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D300

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 4 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D500

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 5 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P02D700

No Sub Type Information

Larger errors can be noticeable at engine idle speed

– PTO is connected incorrectly so that ECM is not informed if it is engaged.

– Low or high flow injector.

– Uneven spaced tooth on flywheel.

– Bad compression.

Injector, see Probable errors

Diagnostic Service 14. No additional action is needed

Check:

Injector, see Probable errors

Cylinder 6 Fuel Injector Offset Learning at Max Limit

————————————————————————————————————————————————————————————

P033531

No Signal

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P033638

Signal Frequency Incorrect

Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running. Possible loss of power

Sensor monting Sensor/Lack of shims

Diagnostic Service 14. No additional action is needed

Check:

Sensor/Lack of shims

Crankshaft Position Sensor A Circuit Range/Performance

————————————————————————————————————————————————————————————

P033900

No Sub Type Information

The engine start time will increase.Engine is running with imprecise timing causing risk of high fuel consumption and smoke. Cylinder balancing not working with risk of uneven running.

Possible loss of power

Harness/sensor monting Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankshaft Position Sensor A Circuit Intermittent

————————————————————————————————————————————————————————————

P203F00

No Sub Type Information

No urea dosing

Urea symbol in cluster

Tank almost empty, stop dosing to maintain cooling ECM interpretation  of raw value. Urea level. DST problem.

Diagnostic Service 14. No additional action is needed

Check:

ECM interpretation  of raw value. Urea level. DST problem.

Reductant Level Low

————————————————————————————————————————————————————————————

P205A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank temp sensor Cables

Connectors

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor

————————————————————————————————————————————————————————————

P208064

Signal Plausibility Failure

None

The sensor is not plausible Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Range/Performance Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220013

Measured voltage outside the limits specified by the sensor

Circuit Open

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P220164

Signal Plausibility Failure

Excessive urea dosing (only for SCR system)

Exhaust system leakage Air intake leakage

Nox-sensor

Dosing system (only for SCR system)

Exhaust system Air intake system

Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Dosing system (only for SCR system) Exhaust system

Air intake system Nox-sensor

NOx Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P060100

No Sub Type Information

Engine derate

signature failure

.

Diagnostic Service 14. No additional action is needed

Check: signature failure

Internal Control Module Memory Check Sum Error

————————————————————————————————————————————————————————————

P060700

No Sub Type

Information

Not possible to reprogram

ECU

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

Performance

————————————————————————————————————————————————————————————

P06151C

Measured voltage outside the limits specified by the sensor

Circuit Voltage Out of Range

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P061600

Measured voltage

below limit

No Sub Type

Information

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Circuit Low

————————————————————————————————————————————————————————————

P061700

Measured voltage above limit

No Sub Type Information

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Circuit High

————————————————————————————————————————————————————————————

P066800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

PCM/ECM/TCM Internal

Temperature Sensor Circuit Low

————————————————————————————————————————————————————————————

P06B100

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit Low

————————————————————————————————————————————————————————————

P06B200

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply A Circuit High

————————————————————————————————————————————————————————————

P06B400

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit Low

————————————————————————————————————————————————————————————

P06B500

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor Power Supply B Circuit High

————————————————————————————————————————————————————————————

P20EE00

No Sub Type Information

NOx-conversion reduced by appr. 50%

Possible ammonia smell

Regent out of specification, Dosing performance low Urea specification

Dosing system

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system

SCR NOx Catalyst Efficiency Below Threshold (Bank 1)

————————————————————————————————————————————————————————————

P261087

Missing Message

Timestamps from Cluster not available

J1708 time data failure and J1939 message does not exist. (Cluster error).

Cluster

Diagnostic Service 14. No additional action is needed

Check: Cluster

ECM/PCM Internal Engine Off Timer Performance

————————————————————————————————————————————————————————————

P2BA700

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Empty Reagent Tank

————————————————————————————————————————————————————————————

P023400

No Sub Type Information

Too high pressure Turbine , Compressor

Diagnostic Service 14. No additional action is needed

Check:

Turbine , Compressor

Turbocharger/Supercharg er Overboost Condition

————————————————————————————————————————————————————————————

P029900

No Sub Type Information

Too low pressure

Boost leakage, wastegate, VGT, compressor.

Diagnostic Service 14. No additional action is needed

Check:

Boost leakage, wastegate, VGT, compressor.

Turbocharger/Supercharg er Underboost

————————————————————————————————————————————————————————————

U300001

Measured voltage outside the limits specified by the

sensor

General Electrical Failure

Possible damage on EMS system components depending on the high

voltage (>36V)

Generator, external charger

Diagnostic Service 14. No additional action is needed

Check:

Generator, external charger

Electronic control unit

————————————————————————————————————————————————————————————

U300041

Program memory corruption

General Checksum Failure

The engine can not be started

No software

Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Electronic control unit

————————————————————————————————————————————————————————————

P007087

Missing Message

None

J1708 and CAN ambient air temperature message does not exist.

Harness. Cluster

Diagnostic Service 14. No additional action is needed

Check:

Harness. Cluster

Ambient Air Temperature Sensor “A”

————————————————————————————————————————————————————————————

P011013

Measured voltage outside the limits specified by the sensor

Circuit Open

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Bank 1

————————————————————————————————————————————————————————————

P011200

Measured voltage below limit

No Sub Type Information

Engine is running but could be difficult to start in cold climate.

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Intake Air Temperature Sensor 1 Circuit Low Bank 1

————————————————————————————————————————————————————————————

P011700

Measured voltage below limit

No Sub Type Information

Engine is difficult to start. Idle run regulation is

detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P021700

No Sub Type Information

Powerloss

Extreme Driving conditions Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Over Temperature Condition

————————————————————————————————————————————————————————————

P047013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Exhaust Pressure Sensor “A”

————————————————————————————————————————————————————————————

P047164

Signal Plausibility Failure

Open loop control enabled. Decreased brake power.

sensor, Closed loop

butterfly,  AVU sensor, butterfly, AVU

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly, AVU

Engine Exhaust Back

Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P047300

Measured voltage above limit

No Sub Type Information

Open loop control enabled. Decreased brake power.

.

Diagnostic Service 14. No additional action is needed

.

Engine Exhaust Back Pressure Circuit High

————————————————————————————————————————————————————————————

P048013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator or wire. Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit

————————————————————————————————————————————————————————————

P051B64

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The crank case pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Engine High Resolution Crankcase Pressure Circuit Range/Performance

————————————————————————————————————————————————————————————

P051A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Crankcase Pressure Sensor

————————————————————————————————————————————————————————————

P051D00

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine High Resolution Crankcase Pressure

————————————————————————————————————————————————————————————

P052300

Measured voltage above limit

No Sub Type Information

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Pressure Circuit High

————————————————————————————————————————————————————————————

P052400

No Sub Type Information

Low pressure, powerloss

Oil leakage, broken oil pump, clogged oil system Oil system

Diagnostic Service 14. No additional action is needed

Check:

Oil system

Engine Oil Pressure Too Low

————————————————————————————————————————————————————————————

P222800

Measured voltage below limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check:

Sensor ECM

Barometric Pressure Circuit Low

————————————————————————————————————————————————————————————

P222900

Measured voltage above limit

No Sub Type Information

None

Internal fault in ECM Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor

ECM

Barometric Pressure Circuit High

————————————————————————————————————————————————————————————

P226400

No Sub Type Information

None

No error: Used for indication

when priming pump is active

None

Diagnostic Service 14. No additional action is needed

Check:

No error: Used for indication when priming pump is active

Water in Fuel Sensor

————————————————————————————————————————————————————————————

P226600

Measured voltage below limit

No Sub Type Information

Will give water in fuel indication.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit Low

————————————————————————————————————————————————————————————

P226700

Measured voltage above limit

No Sub Type Information

Undetected water in fuel can lead to engine stop

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Water In Fuel Indicator Circuit High

————————————————————————————————————————————————————————————

P250C00

Measured voltage below limit

No Sub Type Information

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Engine Oil Level Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P250F00

No Sub Type Information

None

Critically low oil level Leakage

Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Engine Oil Level Too Low

————————————————————————————————————————————————————————————

P255613

Measured voltage outside the limits specified by the

sensor

Circuit Open

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Sensor/Switch

————————————————————————————————————————————————————————————

P255900

Measured voltage above limit

No Sub Type Information

Coolant level can not be detected.

Harness Harness connector

sensor

Diagnostic Service 14. No additional action is needed

Check: Harness connector

sensor

Engine Coolant Level Circuit High

————————————————————————————————————————————————————————————

P256000

No Sub Type Information

Powerloss

Coolant level below range if not Harness

Coolant system

Diagnostic Service 14. No additional action is needed

Check:

Coolant system

Engine Coolant Level Low

————————————————————————————————————————————————————————————

P108600

No Sub Type Information

None

Low oil level Leakage Leakage

Sensor

Diagnostic Service 14. No additional action is needed

Check: Leakage Sensor

Oil Level Moderately Low

————————————————————————————————————————————————————————————

P20BF00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 2 Short Circuit Low

————————————————————————————————————————————————————————————

U014100

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U012A87

Lost communication with the node

Missing Message

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

P208E00

No Sub Type Information

No urea dosing

Sensor/Harness dosing valve

injector, clogged hoses

Diagnostic Service 14. No additional action is needed

Check:

dosing valve

injector, clogged hoses

Aftertreatment Reagent Dosing Valve Clogged

————————————————————————————————————————————————————————————

P109541

General Checksum Failure

Engine derate

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Control Unit

————————————————————————————————————————————————————————————

P109641

General Checksum

Failure

Engine derate

.

Diagnostic Service 14. No additional

action is needed

.

Transmission Control Unit

————————————————————————————————————————————————————————————

P069200

Measured voltage above limit

No Sub Type Information

Fan runs at full speed. Increased fuel consumption may be seen.

Broken actuator, wire or ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit High

————————————————————————————————————————————————————————————

P069100

Measured voltage below limit

No Sub Type Information

Fan always deactivated or

always activated if fault is intermittent.

Broken actuator, wire or

ECM driver output Actuator/Harness

Diagnostic Service 14. No additional action is needed

Check: Actuator/Harness

Fan 1 Control Circuit Low

————————————————————————————————————————————————————————————

U015500

Lost communication with the node on Medium Speed CAN Communication Bus

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Instrument Panel Cluster (IPC) Control Module

————————————————————————————————————————————————————————————

P052013

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil pressure shows 0 in the cluster. Engine is running.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Pressure Sensor/Switch “A”

————————————————————————————————————————————————————————————

P066613

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Internal fault in ECM ECM

Diagnostic Service 14. No additional action is needed

Check: ECM

Control Module Internal Temperature Sensor “A”

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P020113

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 1 Injector “A”

————————————————————————————————————————————————————————————

P020313

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 3 Injector “A”

————————————————————————————————————————————————————————————

P020413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 4 Injector “A”

————————————————————————————————————————————————————————————

P020513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 5 Injector “A”

————————————————————————————————————————————————————————————

P020613

Measured voltage outside the limits specified by the sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 6 Injector “A”

————————————————————————————————————————————————————————————

P220E93

No Operation

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Heater Control Circuit Range/Performance (Bank 1 Sensor 1)

————————————————————————————————————————————————————————————

P250A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

Oil level can not be measured.

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Level Sensor

————————————————————————————————————————————————————————————

P020213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Loss of power and uneven running. Run on three to five cylinders

Harness/Broken solenoid Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Cylinder 2 Injector “A”

————————————————————————————————————————————————————————————

P100E18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 2

————————————————————————————————————————————————————————————

P100F18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 3

————————————————————————————————————————————————————————————

P101018

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 4

————————————————————————————————————————————————————————————

P101518

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 5

————————————————————————————————————————————————————————————

P101618

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 6

————————————————————————————————————————————————————————————

P101711

Measured voltage below limit

Circuit Short To Ground

High fuel consumption due to fuel leakage.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101712

Measured voltage above limit

Circuit Short To Battery

Valve constantly shut.

Broken solenoid, wire or ECM driver output

Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

————————————————————————————————————————————————————————————

P101713

Measured voltage outside the limits specified by the

sensor

Circuit Open

Valve constantly shut.

Broken solenoid or wire. Water-in-fuel valve driver

Diagnostic Service 14. No additional action is needed

Check:

Water-in-fuel valve driver

Water In Fuel Drainage Valve

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P220300

No Sub Type Information

Cabling between Nox- sensor and Nox-sensor ECU Nox-sensor

Nox-sensor cabling Nox-sensor

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor cabling Nox-sensor

NOx Sensor Circuit High Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P2BA800

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Interruption of Reagent Dosing Activity

————————————————————————————————————————————————————————————

P2BA900

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality

————————————————————————————————————————————————————————————

P2BAA00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Low Reagent Consumption

————————————————————————————————————————————————————————————

P2BAD00

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown

————————————————————————————————————————————————————————————

P2BAE96

Component Internal Failure

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System

————————————————————————————————————————————————————————————

P100211

Measured voltage below limit

Circuit Short To Ground

Induction air is hot. Preheat relay is impossible to turn

off.

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Preheat Relay

————————————————————————————————————————————————————————————

P100212

Measured voltage above limit

Circuit Short To Battery

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Preheat relay solenoid shorted

Preheat relay.

Diagnostic Service 14. No additional action is needed

Check: Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100213

Measured voltage outside the limits specified by the sensor

Circuit Open

Preheat relay not activated. White smoke for cold start. Start problems in cold climate.

Harness or Preheat relay solenoid

Harness. Preheat relay.

Diagnostic Service 14. No additional action is needed

Check:

Harness. Preheat relay.

Preheat Relay

————————————————————————————————————————————————————————————

P100629

Signal invalid

None

The boost temperature sensor output is showing constant value.

Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Intake Air Temperature Sensor 1 Stuck Bank 1

————————————————————————————————————————————————————————————

P100713

Measured voltage outside the limits specified by the sensor

Circuit Open

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator

————————————————————————————————————————————————————————————

P100D18

Circuit Current Below Threshold

None

Injector/Harness resistance too high.

Injector/Harness

Diagnostic Service 14. No additional action is needed

Check: Injector/Harness

Injector 1

————————————————————————————————————————————————————————————

P102111

Measured voltage below limit

Circuit Short To Ground

VCB can not be turned off. Causes engine to stop.

Engine impossible to

restart.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P102112

Measured voltage above limit

Circuit Short To Battery

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

P102113

Measured voltage outside the limits specified by the sensor

Circuit Open

VCB can not be turned on. Engine break function derated. Gear shift performance derated for some automatic transmission boxes.

Broken actuator/Harness VCB actuator

Diagnostic Service 14. No additional action is needed

Check:

VCB actuator

Volvo Compression Brake (VCB) Control Circuit

————————————————————————————————————————————————————————————

U010E00

Lost communication with the node

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Lost Communication With Reductant Control

Module

————————————————————————————————————————————————————————————

P019513

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Engine Oil Temperature Sensor “A”

————————————————————————————————————————————————————————————

P204A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Reductant Pressure Sensor

————————————————————————————————————————————————————————————

P203D00

Measured voltage above limit

No Sub Type Information

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Aftertreatment Reagent Level  Short Circuit High

————————————————————————————————————————————————————————————

P208A13

Measured voltage outside the limits specified by the sensor

Circuit Open

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Reductant Pump “A” Control

————————————————————————————————————————————————————————————

P026500

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 2 Short Circuit High

————————————————————————————————————————————————————————————

P026800

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to

five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 3 Short Circuit High

————————————————————————————————————————————————————————————

P027100

Measured voltage above limit

No Sub Type Information

Loss of power and uneven

running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 4 Short Circuit High

————————————————————————————————————————————————————————————

P027400

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 5 Short Circuit High

————————————————————————————————————————————————————————————

P027700

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 6 Short Circuit High

————————————————————————————————————————————————————————————

P20B300

Measured voltage below limit

No Sub Type Information

None

.

Diagnostic Service 14. No additional action is needed

.

Reductant Heater Coolant Control Valve Circuit Low

————————————————————————————————————————————————————————————

P204800

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: DCU ACM Pump module: internal cabling

ACM Pump module: DCU,

ACM Pump module: internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: DCU, ACM Pump module: internal cabling

Aftertreatment Reagent Dosing Valve Short Circuit Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P204713

Measured voltage outside the limits specified by the sensor

Circuit Open

no urea dosing

Cable / Connectors

ACM Dosing module: Dosing valve

Cable / Connectors ACM Dosing module: Dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Cable / Connectors ACM Dosing module: Dosing valve

Reductant Injection Valve Control Bank 1 Unit 1

————————————————————————————————————————————————————————————

P20C300

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 3 Short Circuit Low

————————————————————————————————————————————————————————————

P20BB00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Aftertreatment Reagent Hose Heater 1 Short Circuit Low

————————————————————————————————————————————————————————————

P20A200

Measured voltage below limit

No Sub Type Information

Not possible to perform afterrun

Internal electrical failure in valve within the ACM

Diagnostic Service 14. No additional action is needed

Check:

Internal electrical failure in valve within the ACM

Aftertreatment Reagent Direction Valve Short Circuit Low

————————————————————————————————————————————————————————————

P065900

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit High

————————————————————————————————————————————————————————————

P065800

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

ACM Actuator High Supply 1 Short Circuit Low

————————————————————————————————————————————————————————————

P208D00

Measured voltage above limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short Circut High

————————————————————————————————————————————————————————————

P208C00

Measured voltage below limit

No Sub Type Information

No urea dosing

Wiring harness internal error in pump

Diagnostic Service 14. No additional action is needed

Check:

Wiring harness internal error in pump

Aftertreatment Reagent Pump Control Short Circuit Low

————————————————————————————————————————————————————————————

P203A13

Measured voltage outside the limits specified by the sensor

Circuit Open

None

AdBlue tank level sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

AdBlue tank level sensor, Cables, Connectors

Reductant Level Sensor “A”

————————————————————————————————————————————————————————————

P019700

Measured voltage below limit

No Sub Type Information

None

Harness Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Oil Temperature Short Circuit Low

————————————————————————————————————————————————————————————

P024313

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Broken actuator or wire. Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Turbocharger/Supercharg er Wastegate Solenoid “A”

————————————————————————————————————————————————————————————

P024471

Actuator Stuck

Possible turbo damage

Wategate mechanically damaged

Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate  Stuck Close

————————————————————————————————————————————————————————————

P024500

Measured voltage below limit

No Sub Type Information

Broken actuator, wire or ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit Low

————————————————————————————————————————————————————————————

P024600

Measured voltage above limit

No Sub Type Information

Powerloss

Broken actuator, wire or ECM driver output Wastegate

Diagnostic Service 14. No additional action is needed

Check: Wastegate

Wastegate Short Circuit High

————————————————————————————————————————————————————————————

P026200

Measured voltage above limit

No Sub Type Information

Loss of power and uneven running. Run on three to five cylinders

Harness shorted Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Injector 1 Short Circuit High

————————————————————————————————————————————————————————————

P204300

No Sub Type Information

None

Urea tank temp sensor stuck high

Urea tank temp sensor

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor

Aftertreatment Reagent Tank Temperature Sensor Stuck

————————————————————————————————————————————————————————————

P209F73

Actuator Stuck Closed

None

Urea tank temp sensor or Urea tank heating system Urea tank temp sensor, Urea tank heating system

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Urea tank heating system

Aftertreatment Reagent Tank Temperature

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P20F400

No Sub Type Information

Too low urea consumption

Urea level sensor stuck Clogged urea system Wrong urea tank Wrong dosing module Nozzle or

ACM Dosing module: dosing

valve

Diagnostic Service 14. No additional action is needed

Check:

Nozzle or

ACM Dosing module: dosing valve

AdBlue Consumption Too Low

————————————————————————————————————————————————————————————

U029D00

Lost communication with the node

No Sub Type Information

MS from Nox-sensor ECU Nox-sensor power supply CAN communication between ECM and Nox-EUC

Diagnostic Service 14. No additional action is needed

Check:

Nox-sensor power supply

CAN communication between ECM and Nox-EUC

Lost Communication With NOx Sensor “A”

————————————————————————————————————————————————————————————

P204C00

Measured voltage below limit

No Sub Type Information

No urea dosing

ACM Pump module: AdBlue pressure sensor

ACM Pump module: Internal cabling

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Diagnostic Service 14. No additional action is needed

Check:

ACM Pump module: Urea pressure sensor, ACM Pump module: Internal cabling

Aftertreatment Reagent Pressure Sensor Circuit Low

————————————————————————————————————————————————————————————

U016700

No Sub Type Information

The engine can not be started

Immobilizer unit not installed.  (When Immo in Cluster is used, the Cluster maybe did not wake up properly)

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Lost Communication With Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

U042600

No Sub Type Information

The engine can not be started

ECM and Immobilizer(or Cluster) unit security codes do not match.

Immo system

Diagnostic Service 14. No additional action is needed

Check:

Immo system

Invalid Data Received From Vehicle Immobilizer Control Module

————————————————————————————————————————————————————————————

P114000

No Sub Type Information

No VCB

low engine oil temperature

.

Diagnostic Service 14. No additional action is needed

Check:

low engine oil temperature

Volvo Compression Brake (VCB) Control Oil

Temperature Too Low

————————————————————————————————————————————————————————————

P011164

Signal Plausibility Failure

None

The boost temperature sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Ambient air temperature sensor.

Diagnostic Service 14. No additional action is needed

Check:

Harness Sensor

Ambient air temperature sensor.

Intake Air Temperature Sensor 1 Circuit Range/Performance Bank 1

————————————————————————————————————————————————————————————

P20E892

Performance or Incorrect Operation

No urea dosing

ACM dosing module: Dosing valve leakage.

Bleed orifice leakage, pressure hose lekage, pump internal leakage, empty ureatank

Tank frozen.

if pump/tank-lines are mixed-up when connecting them to the pump unit there will be no pressure built (check color mar Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Diagnostic Service 14. No additional action is needed

Check:

Empty Urea tank, Urea filter clogged, Urea inlet pipe leakage/blocked, Urea tank ventilation, ACM Pump module: Pump

Reductant Pressure Too Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P21CA00

No Sub Type Information

No dozing

Voltage supply to ACM. Voltage supply to Urea

pump.

Diagnostic Service 14. No additional action is needed

Check:

Voltage supply to Urea pump.

Reductant Control Module Supply Voltage

————————————————————————————————————————————————————————————

P114411

Measured voltage

below limit

Circuit Short To Ground

EMS can not control starter

Start relay/harness

Diagnostic Service 14. No additional

action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114412

Measured voltage above limit

Circuit Short To Battery

Impossible to activate starter motor.

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P114413

Measured voltage outside the limits specified by the

sensor

Circuit Open

Impossible to activate starter motor

Start relay/harness

Diagnostic Service 14. No additional action is needed

Check:

Start relay/Harness

Starter Relay Highside

————————————————————————————————————————————————————————————

P116A13

Measured voltage outside the limits specified by the

sensor

Circuit Open

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side

————————————————————————————————————————————————————————————

P116B00

Measured voltage below limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit Low

————————————————————————————————————————————————————————————

P116C00

Measured voltage above limit

No Sub Type Information

No urea dosing

.

Diagnostic Service 14. No additional action is needed

.

Reductant Pump “A” Control Low Side Circuit High

————————————————————————————————————————————————————————————

P021900

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPD activated to lower espd below deactivation limit (commonly 1000rpm).

Engine is/was overspeeding. Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Diagnostic Service 14. No additional action is needed

Check:

Engine could be running on oil, due to e.g. faulty crankcase oil filter.

Engine Overspeed Condition

————————————————————————————————————————————————————————————

P115211

Measured voltage below limit

Circuit Short To Ground

Priming pump permanently on. Possible damage of priming pump.

Actuator/harness Priming pump

Diagnostic Service 14. No additional action is needed

Check: Priming pump

Fuel Priming Pump

————————————————————————————————————————————————————————————

P115212

Measured voltage

above limit

Circuit Short To Battery

Priming or drain aborted

and inhibited

Actuator/harness

Priming pump

Diagnostic Service 14. No additional

action is needed

Check:

Priming pump

Fuel Priming Pump

————————————————————————————————————————————————————————————

P115213

Measured voltage outside the limits specified by the

sensor

Circuit Open

Priming or drain inhibited

Actuator/harness Priming pump

Diagnostic Service 14. No additional action is needed

Check: Priming pump

Fuel Priming Pump

————————————————————————————————————————————————————————————

P115C00

Measured voltage above limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “C” Circuit High

————————————————————————————————————————————————————————————

P115D00

Measured voltage below limit

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control

Module Sensor Power Supply “C” Circuit Low

————————————————————————————————————————————————————————————

P06E970

Actuator Stuck On

The starter motor is deactivated

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the cogwheels of the starter and engine are stuck

Engine Starter Performance

————————————————————————————————————————————————————————————

P06E998

Component or System Over Temperature

The starter motor is deactivated

The starter motor is deactivated due to overheat None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to overheat

Engine Starter Performance

————————————————————————————————————————————————————————————

P115E97

Component or System Operation Obstructed or Blocked

No dozing

Bleed orifice clogged

Bleed orifice, Urea pressure sensor,

Diagnostic Service 14. No additional action is needed

Check:

Bleed orifice, Urea pressure sensor,

Reductant Return No Flow Detected

————————————————————————————————————————————————————————————

P11609B

High/Excessive Flow

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Root Cause Unknown (First Level)

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P116192

Performance or Incorrect Operation

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – Insufficient Reagent Quality (First Level)

————————————————————————————————————————————————————————————

P116300

No Sub Type Information

.

Not possible to erase, will be healed after 400 days. In production, please re- flash the control unit and make sure to enter factory mode next time

.

NOx Exceedence – NOx Control Monitoring System (First Level)

————————————————————————————————————————————————————————————

P26047F

Measured voltage below limit

Actuator Stuck Off

Preheat relay problem or sense SC-.

Shorting wire may break when attempt

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P115600

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control

Module Sensor Power Supply “A” Circuit High

————————————————————————————————————————————————————————————

P115700

No Sub Type Information

.

Diagnostic Service 14. No additional action is needed

.

Reductant Control Module Sensor Power

Supply “A” Circuit Low

————————————————————————————————————————————————————————————

P115800

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control Module Sensor Power

Supply “B” Circuit High

————————————————————————————————————————————————————————————

P115900

No Sub Type Information

Incorrect sensor readings

Harness/Sensor power supply

Harness

Diagnostic Service 14. No additional action is needed

Check: Harness

Reductant Control

Module Sensor Power Supply “B” Circuit Low

————————————————————————————————————————————————————————————

P115A00

No Sub Type Information

Possible incread risk of crystalization

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Exhaust Gas Temperature Sensor Circuit Signal Compare Failure Bank 1

Sensor 1

————————————————————————————————————————————————————————————

P115B00

No Sub Type Information

None

The sensor is stuck Leakage in exhaust system Leakage in intake system Sensor

Diagnostic Service 14. No additional action is needed

Check:

Leakage in exhaust system Leakage in intake system Sensor

Exhaust Gas Temperature Sensor Circuit Stuck Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P116441

General Checksum Failure

All ACM functionality disabled, no urea dosing

No software in ACM

.

Diagnostic Service 14. No additional action is needed

Check:

No software in ACM

Reductant Control Module Internal Control Module Memory Checksum Error

————————————————————————————————————————————————————————————

P116700

No Sub Type Information

The starter motor is deactivated

The starter motor is deactivated due to that the PTO switch is active.

None

Diagnostic Service 14. No additional action is needed

Check:

The starter motor is deactivated due to that the PTO switch is active.

Starter Activated When PTO Is Active

————————————————————————————————————————————————————————————

P000041

General Checksum

Failure

The engine can not be

started

.

Diagnostic Service 14. No additional

action is needed

.

Control Module

————————————————————————————————————————————————————————————

P24FF00

No Sub Type Information

If tank temp is too high, no urea dosing

Urea tank temp is too high Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

Reductant Temperature Too High

————————————————————————————————————————————————————————————

U1FFF68

Event Information

None

None

Diagnostic Service 14. No additional

action is needed

.

Factory Mode Active

————————————————————————————————————————————————————————————

P117A00

No Sub Type Information

Possible ammonia smell

SCR catalyst removed, Regent out of specification, Clogged dosing system Urea specification

Dosing system Catalyst deactivated

Diagnostic Service 14. No additional action is needed

Check:

Urea specification Dosing system Catalyst deactivated

SCR NOx Catalyst Efficiency Critically Below Threshold Bank 1

————————————————————————————————————————————————————————————

P047800

Measured voltage above limit

No Sub Type Information

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A” High

————————————————————————————————————————————————————————————

P047700

Measured voltage

below limit

No Sub Type

Information

Powerloss, engine break is

reduced

Broken actuator/Harness

AVU

Diagnostic Service 14. No additional

action is needed

Check:

AVU

Exhaust Pressure Control

Valve “A” Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P047513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Powerloss, engine break is reduced

Broken actuator/Harness AVU

Diagnostic Service 14. No additional action is needed

Check: AVU

Exhaust Pressure Control Valve “A”

————————————————————————————————————————————————————————————

P222764

Signal Plausibility Failure

Powerloss (minor) P3524:

Black smoke (minor)

The ambient air pressure is showing either too high or to low value.

(abnormal value) Sensor

ECM

Diagnostic Service 14. No additional action is needed

Check: Sensor ECM

Barometric Pressure Sensor “A” Circuit Range/Performance

————————————————————————————————————————————————————————————

P011513

Measured voltage outside the limits specified by the

sensor

Circuit Open

Engine is difficult to start. Idle run regulation is detoriated.

Harness Sensor

Sensor/Harness

Diagnostic Service 14. No additional action is needed

Check: Sensor/Harness

Engine Coolant Temperature Sensor 1

————————————————————————————————————————————————————————————

P205E1F

Circuit Intermittent

Urea tank temp sensor, Cables, Connectors

Diagnostic Service 14. No additional action is needed

Check:

Urea tank temp sensor, Cables, Connectors

Reductant Tank Temperature Sensor Circuit

Intermittent/Erratic

————————————————————————————————————————————————————————————

P053E00

No Sub Type Information

Forced idle Engine shut down

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Too High

————————————————————————————————————————————————————————————

P010513

Measured voltage outside the limits specified by the sensor

Circuit Open

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor

————————————————————————————————————————————————————————————

P010800

Measured voltage above limit

No Sub Type Information

Powerloss

Connectors. Harness. Sensor

Connectors. Harness.

Sensor

Diagnostic Service 14. No additional action is needed

Check: Connectors. Harness.

Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High

————————————————————————————————————————————————————————————

P010662

Signal Compare Failure

Powerloss Black smoke

The boost pressure sensor output is showing either too high or to low value.

(abnormal value) Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Manifold Absolute Pressure/Barometric Pressure Sensor Circuit Range/Performance

————————————————————————————————————————————————————————————

P054070

Measured voltage above limit

Actuator Stuck On

Fuse for shorting wire breaks.

Sense wire SC+ or preheat relay broken

Preheat sense 1

Preheat relay

Diagnostic Service 14. No additional action is needed

Check:

Preheat sense 1 Preheat relay

Intake Air Heater “A” Control

————————————————————————————————————————————————————————————

P225D00

No Sub Type Information

None except fault code and lamp

Sensor removed (measures surround air)

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Signal Stuck Low Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P10F200

Measured voltage below limit

No Sub Type Information

None

Pressure switch / Harness Pressure switch/Harness

Diagnostic Service 14. No additional action is needed

Check:

Pressure switch/Harness

Air Filter Indicator Circuit Low

————————————————————————————————————————————————————————————

P10F300

Measured voltage

above limit

No Sub Type

Information

None

Harness

Diagnostic Service 14. No additional

action is needed

Check:

Harness

Air Filter Indicator Circuit

High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P22FB00

No Sub Type Information

Sensor

Diagnostic Service 14. No additional action is needed

Check: Sensor

NOx Sensor Performance – Sensing Element Bank 1 Sensor 1

————————————————————————————————————————————————————————————

P110400

No Sub Type Information

The engine can not be started

Bad software configuration Software download application

Diagnostic Service 14. No additional action is needed

Check:

Software download application

Factory Mode

————————————————————————————————————————————————————————————

P10F824

Signal Stuck High

.

Diagnostic Service 14. No additional

action is needed

.

Air Filter Clogged

————————————————————————————————————————————————————————————

P029800

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Over Temperature

————————————————————————————————————————————————————————————

P111600

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Moderately Too

High

————————————————————————————————————————————————————————————

P111800

No Sub Type Information

Intermittent Powerloss

VGT stuck, Wastegate stuck VGT Turbo, Wastegate

Diagnostic Service 14. No additional action is needed

Check:

VGT Turbo, Wastegate

Manifold Absolute Pressure Too High

————————————————————————————————————————————————————————————

P111D00

No Sub Type

Information

.

Diagnostic Service 14. No additional

action is needed

.

Engine Coolant Level

Moderately Low

————————————————————————————————————————————————————————————

P111E00

No Sub Type Information

Powerloss

Extreme Driving conditions

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Coolant thermostat

Fan

Blocked radiator

Engine Coolant Temperature Moderately High

————————————————————————————————————————————————————————————

P112500

No Sub Type Information

Powerloss

Extreme driving conditions Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Diagnostic Service 14. No additional action is needed

Check:

Extreme driving conditions Fan

Oil thermostat Coolant system Clogged oil cooler

Engine Oil Temperature Moderately High

————————————————————————————————————————————————————————————

U117888

It has not been possible to send frames on Vehicle Communication Powertrain CAN and It has not been possible to receive frames on Vehicle Communication Powertrain CAN

Bus off

.

Diagnostic Service 14. No additional action is needed

.

Vehicle Communication Powertrain CAN

————————————————————————————————————————————————————————————

P253913

Measured voltage outside the limits specified by the

sensor

Circuit Open

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness Sensor

Low Pressure Fuel System Sensor Circuit

————————————————————————————————————————————————————————————

P254200

Measured voltage above limit

No Sub Type Information

None

Sensor/Harness Harness

Sensor

Diagnostic Service 14. No additional action is needed

Check: Harness

Sensor

Low Pressure Fuel System Sensor Circuit High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

P008A00

No Sub Type Information

Fuel injection can be affected.

High differential pressure over filter.

Leakage Filter

Sensor

Diagnostic Service 14. No additional action is needed

Check: Filter Sensor

Low Pressure Fuel System Pressure – Too Low

————————————————————————————————————————————————————————————

P113500

No Sub Type Information

Engine speed is limited (to commonly 1200rpm). VCB and EPG activated to lower espd below deactivation limit (commonly 1000rpm).

The non-filtered pressure difference (between crankcase pressure and ambient air pressure) is/was above limit. (The fault code will remain during the  entire driving cycle (unless reset).)

E.g. Blow-by at piston ring. NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Diagnostic Service 14. No additional action is needed

Check:

E.g. Blow-by at piston ring.

NOT Crankcase pressure sensor or ambient air pressure sensor!!!

Crankcase Pressure Relative To Ambient Pressure Too High

————————————————————————————————————————————————————————————

P047F71

Actuator Stuck

Decreased brake power.

sensor, Closed loop butterfly

sensor, butterfly

Diagnostic Service 14. No additional action is needed

Check:

sensor, butterfly

Exhaust Pressure Control Valve “A” Stuck Open

          Volvo vehicles, like any other vehicles, also generate many unwarranted error codes. Error codes often occur in heavy duty vehicles due to high torque and high load. The error codes most frequently encountered by users are from from the Adblue system.

         When we say Adblue systems, we often think about system that breaks very easily. These systems are often used in heavy loads and commercial vehicles. Lately, it has begun to be used in passenger cars. these systems are not used in most countries, even if they are mandatory in Europe. Because it is not structured correctly. Even the adblue liquid, that this system uses, is very difficult to find on the market. Like we said, the system is unstable and users are having trouble. It is a very difficult situation when the systems breaks in the middle of road . Repair of the system is very costly and you lose precious time. For this reason, users are often looking for solutions. One of the solution is an Adblue Emulator developed by SAIL TECHNOLOGY. It is a permanent solution and will be there right beside you in every situation. Adblue Emulators, which many users prefer, will not let you down.

So what do these emulators do and what information do they give? Below are the benefits and fault code information of the SAIL Technology Adblue Emulator we have listed for you.

The instructional models are designed for: Volvo B11R (3), Volvo B5LH (3), Volvo B5TL (3), Volvo B8R (3), Volvo FH (4).

Attention: Please visit https://www.canbusemulator.com/en for more detailed information about diagnostic trouble codes

DTC

DTC Code Name

Type of malfunction

P01951F

Engine Oil Temperature Sensor «A»

Circuit Intermittent

B150413

Vision Camera 1 Heater Circuit

Circuit Open

P001676

Crankshaft Position — Correlation with Camshaft Position

Incorrect installation position

P003A99

Turbocharger / turbocharger supercharging control position «A» has exceeded the training threshold

Parameter limit exceeded

P004513

Open in turbocharger / turbocharger supercharging control circuit «A»

Open circuit

P004519

Open in turbocharger / turbocharger supercharging control circuit «A»

Current in the circuit above the threshold

P004577

Open in turbocharger / turbocharger supercharging control circuit «A»

The required position is unattainable

P004591

Open in turbocharger / turbocharger supercharging control circuit «A»

Parametric

P004592

Open in turbocharger / turbocharger supercharging control circuit «A»

Characteristics or malfunctioning

P00459A

Open in turbocharger / turbocharger supercharging control circuit «A»

Working conditions of a component or system

P006964

Correlation of absolute pressure in the reservoir and barometric pressure

Violation of signal reliability

P006E16

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit below the threshold

P006E17

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit above the threshold

P007011

Outdoor temperature sensor «A»

Short to ground

P007015

Outdoor temperature sensor «A»

Circuit short to battery voltage or break

P008700

The pressure in the fuel distribution pipe / system is too low, row 1

No subtype information

P008800

The pressure in the fuel distribution pipe / system is too high, row 1

No subtype information

P008A00

The pressure in the low-pressure fuel system is too low

No subtype information

P008B00

The pressure in the low-pressure fuel system is too high

No subtype information

P008B97

The pressure in the low-pressure fuel system is too high

The operation of the component or system is difficult or blocked

P009011

Control of fuel pressure regulator 1

Short to ground

P009012

Control of fuel pressure regulator 1

Circuit Short to Battery Voltage

P009013

Control of fuel pressure regulator 1

Open circuit

P009400

A leak in the fuel system — a small leak

No subtype information

P009A00

Air temperature at engine intake — correlation

No subtype information

P009B11

Fuel Pressure Relief Control

Short to ground

P009B12

Fuel Pressure Relief Control

Circuit Short to Battery Voltage

P009B13

Fuel Pressure Relief Control

Open circuit

P009B73

Fuel Pressure Relief Control

The actuator jammed in the closed position

P00AF41

Performance characteristics of the turbocharger / turbocharger supercharger control module «A»

Total checksum error

P00C600

Too low pressure in the fuel distribution pipe — engine crankshaft rotation

No subtype information

P010501

Absolute pressure sensor in the manifold / barometric pressure

General electrical fault

P010512

Absolute pressure sensor in the manifold / barometric pressure

Circuit Short to Battery Voltage

P010513

Absolute pressure sensor in the manifold / barometric pressure

Open circuit

P010562

Absolute pressure sensor in the manifold / barometric pressure

Signal comparison error

P011001

Intake air temperature sensor 1, row 1

General electrical fault

P011011

Intake air temperature sensor 1, row 1

Short to ground

P011013

Intake air temperature sensor 1, row 1

Open circuit

P011501

Engine Coolant Temperature Sensor 1

General electrical fault

P011511

Engine Coolant Temperature Sensor 1

Short to ground

P011513

Engine Coolant Temperature Sensor 1

Open circuit

P01152A

Engine Coolant Temperature Sensor 1

Stuck signal in the range

P012011

Throttle / Pedal Position Sensor «A»

Short to ground

P012012

Throttle / Pedal Position Sensor «A»

Circuit Short to Battery Voltage

P012800

Coolant thermostat (coolant temperature below the thermostat control temperature)

No subtype information

P016800

Fuel temperature in engine too high

No subtype information

P016E00

Control of the fuel pressure in a closed loop at the limit is too high a pressure

No subtype information

P016F00

Controlling the fuel pressure in a closed loop at the limit is too low a pressure

No subtype information

P018501

Fuel temperature sensor «B»

General electrical fault

P018511

Fuel temperature sensor «B»

Short to ground

P018513

Fuel temperature sensor «B»

Open circuit

P018564

Fuel temperature sensor «B»

Violation of signal reliability

P019001

Pressure sensor in the fuel distributor pipe, row 1

General electrical fault

P019011

Pressure sensor in the fuel distributor pipe, row 1

Short to ground

P019013

Pressure sensor in the fuel distributor pipe, row 1

Open circuit

P019062

Pressure sensor in the fuel distributor pipe, row 1

Signal comparison error

P019064

Pressure sensor in the fuel distributor pipe, row 1

Violation of signal reliability

P019511

Engine oil temperature sensor «A»

Short to ground

P019513

Engine oil temperature sensor «A»

Open circuit

P019564

Engine oil temperature sensor «A»

Violation of signal reliability

P01B901

Engine oil temperature sensor «B»

General electrical fault

P01B911

Engine oil temperature sensor «B»

Short to ground

P01B913

Engine oil temperature sensor «B»

Open circuit

P020111

Cylinder 1 nozzle «A»

Short to ground

P020112

Cylinder 1 nozzle «A»

Circuit Short to Battery Voltage

P020113

Cylinder 1 nozzle «A»

Open circuit

P020156

Cylinder 1 nozzle «A»

Invalid / incompatible configuration

P020211

Cylinder 2 injector «A»

Short to ground

P020212

Cylinder 2 injector «A»

Circuit Short to Battery Voltage

P020213

Cylinder 2 injector «A»

Open circuit

P020256

Cylinder 2 injector «A»

Invalid / incompatible configuration

P020311

Cylinder 3 injector «A»

Short to ground

P020312

Cylinder 3 injector «A»

Circuit Short to Battery Voltage

P020313

Cylinder 3 injector «A»

Open circuit

P020356

Cylinder 3 injector «A»

Invalid / incompatible configuration

P020411

Cylinder 4 nozzle «A»

Short to ground

P020412

Cylinder 4 nozzle «A»

Circuit Short to Battery Voltage

P020413

Cylinder 4 nozzle «A»

Open circuit

P020456

Cylinder 4 nozzle «A»

Invalid / incompatible configuration

P020511

Cylinder 5 injector «A»

Short to ground

P020512

Cylinder 5 injector «A»

Circuit Short to Battery Voltage

P020513

Cylinder 5 injector «A»

Open circuit

P020556

Cylinder 5 injector «A»

Invalid / incompatible configuration

P020611

Cylinder 6 nozzle «A»

Short to ground

P020612

Cylinder 6 nozzle «A»

Circuit Short to Battery Voltage

P020613

Cylinder 6 nozzle «A»

Open circuit

P020656

Cylinder 6 nozzle «A»

Invalid / incompatible configuration

P021700

Engine coolant temperature exceeded status

No subtype information

P021800

The condition of the transmission oil temperature rise

No subtype information

P021900

State of excess of engine speed

No subtype information

P023400

Overcharging state of turbocharger / supercharger

No subtype information

P024311

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Short to ground

P024312

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Circuit Short to Battery Voltage

P024313

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Open circuit

P025612

Fuel Injector Diesel Injector

Circuit Short to Battery Voltage

P025614

Fuel Injector Diesel Injector

Short to ground or open

P025692

Fuel Injector Diesel Injector

Characteristics or malfunctioning

P026A00

The efficiency of the charge air cooler is below the threshold

No subtype information

P029800

Excess temperature of engine oil

No subtype information

P029900

Insufficient supercharging of the turbocharger / supercharger

No subtype information

P02CC00

Fuel injector cylinder 1 — determination of the correction at the minimum limit

No subtype information

P02CD00

Fuel injector cylinder 1 — determination of the correction at the maximum limit

No subtype information

P02CE00

Fuel injector cylinder 2 — determination of the correction at the minimum limit

No subtype information

P02CF00

Fuel injector cylinder 2 — determination of the correction at the maximum limit

No subtype information

P02D000

Fuel injector cylinder 3 — determination of the correction at the minimum limit

No subtype information

P02D100

Fuel injector cylinder 3 — determination of the correction at the maximum limit

No subtype information

P02D200

Fuel injector of the cylinder 4 — determination of the correction at the minimum limit

No subtype information

P02D300

Fuel injector cylinder 4 — determination of the correction at the maximum limit

No subtype information

P02D400

Fuel injector cylinder 5 — determination of the correction at the minimum limit

No subtype information

P02D500

Fuel injector cylinder 5 — determination of the correction at the maximum limit

No subtype information

P02D600

Fuel injector of the cylinder 6 — determination of the correction at the minimum limit

No subtype information

P02D700

Fuel injector of the cylinder 6 — determination of the correction at the maximum limit

No subtype information

P02E011

Airflow control at the diesel engine inlet

Short to ground

P02E012

Airflow control at the diesel engine inlet

Circuit Short to Battery Voltage

P02E013

Airflow control at the diesel engine inlet

Open circuit

P02E07C

Airflow control at the diesel engine inlet

Slow reaction

P02E09B

Airflow control at the diesel engine inlet

High / excessive flow

P02E09C

Airflow control at the diesel engine inlet

Low / insufficient flow

P02E601

Diesel Engine Admission Regulator Position Sensor

General electrical fault

P02E612

Diesel Engine Admission Regulator Position Sensor

Circuit Short to Battery Voltage

P02E613

Diesel Engine Admission Regulator Position Sensor

Open circuit

P02E697

Diesel Engine Admission Regulator Position Sensor

The operation of the component or system is difficult or blocked

P02E699

Diesel Engine Admission Regulator Position Sensor

Parameter limit exceeded

P03351F

Crankshaft Position Sensor «A»

Intermittent signal in the circuit

P033531

Crankshaft Position Sensor «A»

Missing signal

P033538

Crankshaft Position Sensor «A»

Incorrect signal frequency

P034031

Camshaft position sensor «A» — row 1 or separate sensor

Missing signal

P034038

Camshaft position sensor «A» — row 1 or separate sensor

Incorrect signal frequency

P04007C

Exhaust gas recirculation flow «A»

Slow reaction

P04009B

Exhaust gas recirculation flow «A»

High / excessive flow

P04009C

Exhaust gas recirculation flow «A»

Low / insufficient flow

P040311

Control of EGR «A»

Short to ground

P040312

Control of EGR «A»

Circuit Short to Battery Voltage

P040313

Control of EGR «A»

Open circuit

P040341

Control of EGR «A»

Total checksum error

P040371

Control of EGR «A»

Driven drive

P040392

Control of EGR «A»

Characteristics or malfunctioning

P040901

The differential pressure sensor EGR

General electrical fault

P040912

The differential pressure sensor EGR

Circuit Short to Battery Voltage

P040913

The differential pressure sensor EGR

Open circuit

P040964

The differential pressure sensor EGR

Violation of signal reliability

P040A01

Temperature sensor «A» of the exhaust gas recirculation system

General electrical fault

P040A11

Temperature sensor «A» of the exhaust gas recirculation system

Short to ground

P040A13

Temperature sensor «A» of the exhaust gas recirculation system

Open circuit

P040A64

Temperature sensor «A» of the exhaust gas recirculation system

Violation of signal reliability

P041A11

Temperature sensor circuit «B» of the exhaust gas recirculation system

Short to ground

P041A12

Temperature sensor circuit «B» of the exhaust gas recirculation system

Circuit Short to Battery Voltage

P041A2A

Temperature sensor circuit «B» of the exhaust gas recirculation system

Stuck signal in the range

P042000

The efficiency of the catalyst system is below the threshold

No subtype information

P047001

The gauge of pressure of exhaust gases «A»

General electrical fault

P047012

The gauge of pressure of exhaust gases «A»

Circuit Short to Battery Voltage

P047013

The gauge of pressure of exhaust gases «A»

Open circuit

P047064

The gauge of pressure of exhaust gases «A»

Violation of signal reliability

P047511

Exhaust Pressure Control Valve «A»

Short to ground

P047512

Exhaust Pressure Control Valve «A»

Circuit Short to Battery Voltage

P047513

Exhaust Pressure Control Valve «A»

Open circuit

P047572

Exhaust Pressure Control Valve «A»

The actuator jammed in the open position

P048011

Fan control circuit 1

Short to ground

P048012

Fan control circuit 1

Circuit Short to Battery Voltage

P048013

Fan control circuit 1

Open circuit

P048613

Sensor «B» of the EGR system

Open circuit

P049D99

Control position «A» EGR exceeded the threshold of training

Parameter limit exceeded

P04D900

Control of the closed loop EGR system at the limit — the flow is too small

No subtype information

P04DA00

Control of the closed loop EGR system at the limit — the flow is too strong

No subtype information

P050011

Vehicle speed by wheel

Short to ground

P050013

Vehicle speed by wheel

Open circuit

P051A01

Crankcase Pressure Sensor

General electrical fault

P051A12

Crankcase Pressure Sensor

Circuit Short to Battery Voltage

P051A13

Crankcase Pressure Sensor

Open circuit

P051A64

Crankcase Pressure Sensor

Violation of signal reliability

P052001

Engine oil pressure switch / relay «A»

General electrical fault

P052012

Engine oil pressure switch / relay «A»

Circuit Short to Battery Voltage

P052013

Engine oil pressure switch / relay «A»

Open circuit

P052064

Engine oil pressure switch / relay «A»

Violation of signal reliability

P052400

Engine oil pressure too low

Engine oil pressure too low

P052607

Fan Speed ​​Sensor Circuit

Mechanical faults

P052612

Fan Speed ​​Sensor Circuit

Circuit Short to Battery Voltage

P053E00

Crankcase pressure — too high

No subtype information

P054001

Control of the inlet air heater «A»

General electrical fault

P054011

Control of the inlet air heater «A»

Short to ground

P054013

Control of the inlet air heater «A»

Open circuit

P054070

Control of the inlet air heater «A»

Drive stuck when on

P05407F

Control of the inlet air heater «A»

Drive stuck when turned off

P054464

Exhaust temperature sensor — Row 1 Sensor 1

Violation of signal reliability

P055A01

Engine oil pressure switch / relay «B»

General electrical fault

P055A12

Engine oil pressure switch / relay «B»

Circuit Short to Battery Voltage

P055A13

Engine oil pressure switch / relay «B»

Open circuit

P055A64

Engine oil pressure switch / relay «B»

Violation of signal reliability

P055F00

Engine oil pressure out of range

No subtype information

P05E311

Parking brake sensor / switch circuit

Short to ground

P05E362

Parking brake sensor / switch circuit

Signal comparison error

P05E364

Parking brake sensor / switch circuit

Violation of signal reliability

P061511

Starter relay

Short to ground

P061512

Starter relay

Circuit Short to Battery Voltage

P061513

Starter relay

Open circuit

P06279C

Fuel pump control «A»

Low / insufficient flow

P064111

Sensor reference voltage «A»

Short to ground

P064112

Sensor reference voltage «A»

Circuit Short to Battery Voltage

P06411C

Sensor reference voltage «A»

Output from the voltage range in the circuit

P065111

Sensor reference voltage «V»

Short to ground

P066601

Internal temperature sensor for control module «A»

General electrical fault

P066611

Internal temperature sensor for control module «A»

Short to ground

P06B016

Sensor supply voltage «A»

Voltage in the circuit below the threshold

P06B017

Sensor supply voltage «A»

Voltage in the circuit above the threshold

P06B316

Sensor supply «B»

Voltage in the circuit below the threshold

P06B317

Sensor supply «B»

Voltage in the circuit above the threshold

P06DA71

Engine Oil Pressure Adjustment

Driven drive

P06E616

Sensor supply voltage «C»

Voltage in the circuit below the threshold

P06E617

Sensor supply voltage «C»

Voltage in the circuit above the threshold

P073021

Recommended transfer

The amplitude of the signal is less than the minimum

P073022

Recommended transfer

The amplitude of the signal above the maximum value

P07307C

Recommended transfer

Slow reaction

P100101

Engine stop switch

General electrical fault

P100111

Engine stop switch

Short to ground

P100112

Engine stop switch

Circuit Short to Battery Voltage

P100190

Engine stop switch

Clogged in the open position

P100192

Engine stop switch

Characteristics or malfunctioning

P100211

Pre-heater heater relay

Short to ground

P100212

Pre-heater heater relay

Circuit Short to Battery Voltage

P100213

Pre-heater heater relay

Open circuit

P100701

Air filter indicator

General electrical fault

P100711

Air filter indicator

Short to ground

P100712

Air filter indicator

Circuit Short to Battery Voltage

P100713

Air filter indicator

Open circuit

P101711

Valve for draining water from fuel

Short to ground

P101E11

The valve of full blocking of the channel of a transmission

Short to ground

P101E12

The valve of full blocking of the channel of a transmission

Circuit Short to Battery Voltage

P101E13

The valve of full blocking of the channel of a transmission

Open circuit

P102111

Volvo Compression Brake Control Circuit (VCB)

Short to ground

P102112

Volvo Compression Brake Control Circuit (VCB)

Circuit Short to Battery Voltage

P102113

Volvo Compression Brake Control Circuit (VCB)

Open circuit

P108600

The oil level is moderately low

No subtype information

P109300

Engine oil pressure is moderately low

No subtype information

P10C011

Volvo Compression Brake Control Circuit (VCB) «2»

Short to ground

P10C012

Volvo Compression Brake Control Circuit (VCB) «2»

Circuit Short to Battery Voltage

P10C013

Volvo Compression Brake Control Circuit (VCB) «2»

Open circuit

P10E100

Differential pressure in particulate filter is critical

No subtype information

P10E200

Differential pressure on particulate filter moderately high

No subtype information

P10F800

Air filter clogged

No subtype information

P10FE00

Clogging of particulate filter — soot accumulation moderately high — row 1

No subtype information

P110400

Factory setting

No subtype information

P110501

Back-up switch circuit «A» of the engine

General electrical fault

P110511

Back-up switch circuit «A» of the engine

Short to ground

P110512

Back-up switch circuit «A» of the engine

Circuit Short to Battery Voltage

P110573

Back-up switch circuit «A» of the engine

The actuator jammed in the closed position

P111600

Absolute pressure sensor in the reservoir is a moderate excess

No subtype information

P111800

Absolute pressure sensor in the collector — a strong excess

No subtype information

P111945

The intake manifold temperature is too high at a moderate level

Failure of program memory

P111A00

Intake manifold temperature too high

No subtype information

P111D00

The engine coolant level is moderately low

No subtype information

P111E00

Engine coolant temperature is moderately high

No subtype information

P112500

Engine oil temperature — moderately high

No subtype information

P112800

The oil pressure for cooling the pistons is moderately low

No subtype information

P112900

Transmission oil temperature moderately high

No subtype information

P112B00

The turbocharger / turbocharger drive temperature «A»

No subtype information

P112E00

Exhaust gas temperature moderately high — row 1

No subtype information

P113411

Air purge valve for fuel injection into the exhaust aftertreatment system

Short to ground

P113413

Air purge valve for fuel injection into the exhaust aftertreatment system

Open circuit

P113472

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the open position

P113473

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the closed position

P113500

Crankcase pressure too high relative to atmospheric pressure

No subtype information

P113600

Error of calibration of the correlation of NOx 1/2 sensors — row 1

No subtype information

P113711

Oil thermostat

Short to ground

P113712

Oil thermostat

Circuit Short to Battery Voltage

P113713

Oil thermostat

Open circuit

P113F11

Idling switch confirmation cable with buffering — VECU side

Short to ground

P113F12

Idling switch confirmation cable with buffering — VECU side

Circuit Short to Battery Voltage

P114000

Volvo Compression Brake Control (VCB) — too low oil temperature

No subtype information

P114101

Idling switch confirmation cable with buffering — ECM side

General electrical fault

P114113

Idling switch confirmation cable with buffering — ECM side

Open circuit

P114123

Idling switch confirmation cable with buffering — ECM side

Constantly low signal level

P114124

Idling switch confirmation cable with buffering — ECM side

Constantly high signal level

P114411

High voltage side of the starter relay

Short to ground

P114412

High voltage side of the starter relay

Circuit Short to Battery Voltage

P114413

High voltage side of the starter relay

Open circuit

P114500

The level of the reducing agent is moderately low

No subtype information

P114700

Pressure in the fuel distribution pipe / system, row 1 — moderately too high

No subtype information

P114B00

The turbocharger / turbocharger drive temperature «A» is too low

No subtype information

P114E00

EGR drive temperature outside the operating range

No subtype information

P115000

Correlation of Sensor / Switch Voltage «A» / «D» Throttle Position / Pedal Position

No subtype information

P115100

Excess temperature of the post-treatment system

No subtype information

P115211

Starting fuel pump

Short to ground

P115212

Starting fuel pump

Circuit Short to Battery Voltage

P115213

Starting fuel pump

Open circuit

P115400

The connection between the bodywork control module «A» and the instrument cluster control module (IPC)

No subtype information

P117311

Low Transmission Range Authorization Valve

Short to ground

P117312

Low Transmission Range Authorization Valve

Circuit Short to Battery Voltage

P117313

Low Transmission Range Authorization Valve

Open circuit

P117401

Transmission range inquiry

General electrical fault

P117411

Transmission range inquiry

Short to ground

P117412

Transmission range inquiry

Circuit Short to Battery Voltage

P117600

Starter motor is deactivated — temperature rise

No subtype information

P117700

Starter motor is deactivated — gearbox is not in neutral position

No subtype information

P117800

The starter motor is deactivated — the gear of the electric motor of the starter motor is stuck

No subtype information

P117900

Starter motor is deactivated — power take-off is active

No subtype information

P117B01

Temperature sensor switch in engine compartment

General electrical fault

P117B11

Temperature sensor switch in engine compartment

Short to ground

P117B12

Temperature sensor switch in engine compartment

Circuit Short to Battery Voltage

P117C00

The requested range of gears is too high

No subtype information

P117D00

Requested driver transfer too low

No subtype information

P117E00

Driver’s request is too high

No subtype information

P117F11

Bypass valve of the hydraulic valve

Short to ground

P117F12

Bypass valve of the hydraulic valve

Circuit Short to Battery Voltage

P117F13

Bypass valve of the hydraulic valve

Open circuit

P203164

Exhaust temperature sensor — Row 1 Sensor 2

Violation of signal reliability

P203A86

Reagent level sensor «A»

Invalid signal

P203F00

Reducer level is low

No subtype information

P204F93

Characteristics of the SCR system — dosing failure

Does not work

P207F9A

Quality of the reducing agent

Working conditions of a component or system

P20D711

Controlling the fuel supply to the exhaust aftertreatment system

Short to ground

P20D713

Controlling the fuel supply to the exhaust aftertreatment system

Open circuit

P20D773

Controlling the fuel supply to the exhaust aftertreatment system

The actuator jammed in the closed position

P20DD01

Fuel pressure sensor for exhaust gas aftertreatment

General electrical fault

P20DD12

Fuel pressure sensor for exhaust gas aftertreatment

Circuit Short to Battery Voltage

P20DD13

Fuel pressure sensor for exhaust gas aftertreatment

Open circuit

P20EE00

The efficiency of the SCR NOx catalyst is below the threshold (row 1)

No subtype information

P20F400

AdBlue consumption is too low

No subtype information

P20F500

Reducer consumption too high

No subtype information

P210900

Performance characteristics of the «A» minimum limiter of the throttle / pedal position

No subtype information

P213600

Correlation of Sensor / Switch Voltage «A» / «C» Throttle Position / Pedal Position

No subtype information

P215A62

Correlation of vehicle speed with wheel speed

Signal comparison error

P215A64

Correlation of vehicle speed with wheel speed

Violation of signal reliability

P216300

Performance characteristics of the maximum limit sensor «A» of the throttle / pedal position

No subtype information

P220012

NOx sensor — series 1 sensor 1

Circuit Short to Battery Voltage

P220013

NOx sensor — series 1 sensor 1

Open circuit

P22001C

NOx sensor — series 1 sensor 1

Output from the voltage range in the circuit

P220064

NOx sensor — series 1 sensor 1

Violation of signal reliability

P220093

NOx sensor — series 1 sensor 1

Does not work

P222601

Barometric pressure circuit

General electrical fault

P222612

Barometric pressure circuit

Circuit Short to Battery Voltage

P222613

Barometric pressure circuit

Open circuit

P222664

Barometric pressure circuit

Violation of signal reliability

P225C00

Characteristics of the NOx sensor — high level signaling — row 1 sensor 1

No subtype information

P225D00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 1

No subtype information

P225E67

Characteristics of the NOx sensor — high level signaling — row 1 sensor 2

Wrong signal after event

P225F00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 2

No subtype information

P226401

Water sensor in fuel

General electrical fault

P226411

Water sensor in fuel

Short to ground

P226413

Water sensor in fuel

Open circuit

P228D72

The fuel pressure regulator 1 has exceeded the control limits — too high a pressure

The actuator jammed in the open position

P228E00

The fuel pressure regulator 1 has exceeded the training limits — too low a pressure

No subtype information

P228F00

The fuel pressure regulator 1 has exceeded the training limits — too high a pressure

No subtype information

P229E12

NOx sensor — row 1 sensor 2

Circuit Short to Battery Voltage

P229E13

NOx sensor — row 1 sensor 2

Open circuit

P229E1C

NOx sensor — row 1 sensor 2

Output from the voltage range in the circuit

P229E64

NOx sensor — row 1 sensor 2

Violation of signal reliability

P229E93

NOx sensor — row 1 sensor 2

Does not work

P22FB92

Sensor Specifications NOx — Sensor — Row 1 Sensor 1

Characteristics or malfunctioning

P22FE00

Sensor Specifications NOx — Sensor — Row 1 Sensor 2

No subtype information

P242800

Exhaust gas temperature too high

No subtype information

P242A64

Exhaust temperature sensor — Row 1 Sensor 3

Violation of signal reliability

P244A00

Differential pressure on the diesel particulate filter after-treatment 1 is too small (row 1)

No subtype information

P244B00

The differential pressure on the diesel particulate filter after-treatment 1 is too large (row 1)

No subtype information

P244C00

The exhaust gas temperature is too low to regenerate the particulate filter (row 1)

No subtype information

P245264

Particulate filter pressure sensor «A»

Violation of signal reliability

P245700

Coolant efficiency of the exhaust gas recirculation system is below the threshold value

No subtype information

P246300

Clogged particulate filter — soot accumulation — row 1

No subtype information

P249D00

Control of the injection of the reducing agent in a closed loop at the limit — the flow is too small

No subtype information

P249E00

Injection of the reducing agent in a closed loop at the limit — the flow is too high

No subtype information

P249F92

Excessive time for switching to the closed-loop diesel particulate filter regeneration control mode

Characteristics or malfunctioning

P24A000

Control of DPF regeneration in a closed loop at the limit — the temperature is too low

No subtype information

P24A100

Control of DPF regeneration in a closed loop at the limit — the temperature is too high

No subtype information

P24A200

The regeneration of the diesel particulate filter is not complete (row 1)

No subtype information

P24A400

Clogging of the diesel particulate filter — soot accumulation too large (row 1)

No subtype information

P250A11

Engine oil level sensor

Short to ground

P250A13

Engine oil level sensor

Open circuit

P250F00

Engine oil level too low

No subtype information

P253901

Low Fuel Pressure Sensor Circuit

General electrical fault

P253912

Low Fuel Pressure Sensor Circuit

Circuit Short to Battery Voltage

P253913

Low Fuel Pressure Sensor Circuit

Open circuit

P255601

Engine Coolant Level Sensor / Relay

General electrical fault

P255611

Engine Coolant Level Sensor / Relay

Short to ground

P255612

Engine Coolant Level Sensor / Relay

Circuit Short to Battery Voltage

P255613

Engine Coolant Level Sensor / Relay

Open circuit

P256000

Engine Coolant Level — Low

No subtype information

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P259C00

Excessive time for entering the supercharging control of the turbocharger «A» in a closed loop

No subtype information

P25A911

Control oil supply for cooling pistons

Short to ground

P25A912

Control oil supply for cooling pistons

Circuit Short to Battery Voltage

P25A913

Control oil supply for cooling pistons

Open circuit

P25A971

Control oil supply for cooling pistons

Driven drive

P25AE00

The oil pressure for cooling the pistons is too low

No subtype information

P260011

Coolant Pump Control Circuit / Break

Short to ground

P260012

Coolant Pump Control Circuit / Break

Circuit Short to Battery Voltage

P260013

Coolant Pump Control Circuit / Break

Open circuit

P268111

Control of the bypass valve «A» of the engine coolant

Short to ground

P268112

Control of the bypass valve «A» of the engine coolant

Circuit Short to Battery Voltage

P268113

Control of the bypass valve «A» of the engine coolant

Open circuit

P269711

Injection Fuel Injector «A»

Short to ground

P269713

Injection Fuel Injector «A»

Open circuit

P269773

Injection Fuel Injector «A»

The actuator jammed in the closed position

P26977A

Injection Fuel Injector «A»

Fluid leakage or seal failure

P2A1612

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Circuit Short to Battery Voltage

P2A1614

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Short to ground or open

P2A1692

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Characteristics or malfunctioning

P2A1E12

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Circuit Short to Battery Voltage

P2A1E14

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Short to ground or open

P2A1E92

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Characteristics or malfunctioning

U000188

CAN Backbone bus 2 communication network

Bus Off

U001088

CAN Backbone bus 1 of the communication network

Bus Off

U008088

Communication Subnet of the car engine

Bus Off

U010100

Lost Communication With TECU

No subtype information

U010A00

Lost communication with the A module of the exhaust gas recirculation system

No subtype information

U010C00

The communication with the turbocharger / supercharger control module is broken

No subtype information

U012100

The communication with the anti-lock braking system (ABS)

No subtype information

U012900

Lost Communication With Brake Control Module

No subtype information

U014100

Lost connection with VMCU

No subtype information

U014200

Lost connection with the body control module «B»

No subtype information

U015500

Communication with the instrument cluster control module (IPC) is broken

No subtype information

U016700

Lost communication with the car immobilizer control module

No subtype information

U029D00

Communication with NOx sensor «A» is broken

No subtype information

U029E00

The communication with the NOx sensor «B» is broken

No subtype information

U032300

Software incompatibility with the dashboard control module

No subtype information

U033100

Incompatibility of software with the bodywork control module «A»

No subtype information

U042600

From the immobilizer control module of the car, unreliable data

No subtype information

U116600

Lost communication with CIOM

No subtype information

U116900

Lost connection with DACU

No subtype information

U116B00

Communication with TCM on the high-speed communication bus CAN

No subtype information

U116C00

Communication with TCM on the CAN bus of the power plant is broken

No subtype information

U116F00

Communication with the control module of the supply of the reducing agent via the engine subnetwork is broken

No subtype information

U117100

The communication with the control unit of the body equipment via the high-speed communication bus CAN

No subtype information

U117300

The communication with the IPC control unit via the high-speed communication CAN

No subtype information

U117888

CAN bus communication system bus

Bus Off

U1FFF68

Factory mode active

Event details

U300001

Electronic control module

General electrical fault

U300041

Electronic control module

Total checksum error

U300044

Electronic control module

Data memory failure

U300045

Electronic control module

Failure of program memory

U300049

Electronic control module

Internal failure of electronics

U300257

Vehicle Identification Number

Invalid / incompatible software component

Описание ошибки U029D00
Блок управления дозировкой (DCU) управляет количеством впрыска карбамида, временем впрыска, подогревом линии карбамида и резервуаром, а также управляет различными датчиками (датчик температуры отработавших газов, датчик уровня карбамида, датчик NOx). Датчик NOx отправляет и принимает информацию по связи CAN и передает информацию самодиагностики в ECU.
Если блок DCU не получает CAN-сообщение (концентрация оксидов азота и информация, связанная с диагностикой ошибки) от контроллера переднего датчика оксида азота в течение определенного периода времени, регистрируется код неисправности DTC U029D00.

Возможная причина ошибки U029D00
Плохой контакт в разъеме
Проверьте связь между передним датчиком оксидов азота и блоком DCU по шине CAN или отсутствие между ними короткого замыкания
Контроллер переднего датчика NOx

Понравилась статья? Поделить с друзьями:
  • U0401 ошибка ford transit
  • U029d00 ошибка volvo fh4
  • U0401 ошибка ford mondeo 4
  • U029d00 ошибка renault
  • U0300 55 ошибка land rover discovery 3