U012900 ошибка volvo

          Volvo vehicles, like any other vehicles, also generate many unwarranted error codes. Error codes often occur in heavy duty vehicles due to high torque and high load. The error codes most frequently encountered by users are from from the Adblue system.

         When we say Adblue systems, we often think about system that breaks very easily. These systems are often used in heavy loads and commercial vehicles. Lately, it has begun to be used in passenger cars. these systems are not used in most countries, even if they are mandatory in Europe. Because it is not structured correctly. Even the adblue liquid, that this system uses, is very difficult to find on the market. Like we said, the system is unstable and users are having trouble. It is a very difficult situation when the systems breaks in the middle of road . Repair of the system is very costly and you lose precious time. For this reason, users are often looking for solutions. One of the solution is an Adblue Emulator developed by SAIL TECHNOLOGY. It is a permanent solution and will be there right beside you in every situation. Adblue Emulators, which many users prefer, will not let you down.

So what do these emulators do and what information do they give? Below are the benefits and fault code information of the SAIL Technology Adblue Emulator we have listed for you.

The instructional models are designed for: Volvo B11R (3), Volvo B5LH (3), Volvo B5TL (3), Volvo B8R (3), Volvo FH (4).

Attention: Please visit https://canbusemulator.com for more detailed information about diagnostic trouble codes

DTC DTC

DTC Code Name

Type of malfunction

P001676

Crankshaft Position — Correlation with Camshaft Position

Incorrect installation position

P003A99

Turbocharger / turbocharger supercharging control position «A» has exceeded the training threshold

Parameter limit exceeded

P004513

Open in turbocharger / turbocharger supercharging control circuit «A»

Open circuit

P004519

Open in turbocharger / turbocharger supercharging control circuit «A»

Current in the circuit above the threshold

P004577

Open in turbocharger / turbocharger supercharging control circuit «A»

The required position is unattainable

P004591

Open in turbocharger / turbocharger supercharging control circuit «A»

Parametric

P004592

Open in turbocharger / turbocharger supercharging control circuit «A»

Characteristics or malfunctioning

P00459A

Open in turbocharger / turbocharger supercharging control circuit «A»

Working conditions of a component or system

P006964

Correlation of absolute pressure in the reservoir and barometric pressure

Violation of signal reliability

P006E16

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit below the threshold

P006E17

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit above the threshold

P007011

Outdoor temperature sensor «A»

Short to ground

P007015

Outdoor temperature sensor «A»

Circuit short to battery voltage or break

P008700

The pressure in the fuel distribution pipe / system is too low, row 1

No subtype information

P008800

The pressure in the fuel distribution pipe / system is too high, row 1

No subtype information

P008A00

The pressure in the low-pressure fuel system is too low

No subtype information

P008B00

The pressure in the low-pressure fuel system is too high

No subtype information

P008B97

The pressure in the low-pressure fuel system is too high

The operation of the component or system is difficult or blocked

P009011

Control of fuel pressure regulator 1

Short to ground

P009012

Control of fuel pressure regulator 1

Circuit Short to Battery Voltage

P009013

Control of fuel pressure regulator 1

Open circuit

P009400

A leak in the fuel system — a small leak

No subtype information

P009A00

Air temperature at engine intake — correlation

No subtype information

P009B11

Fuel Pressure Relief Control

Short to ground

P009B12

Fuel Pressure Relief Control

Circuit Short to Battery Voltage

P009B13

Fuel Pressure Relief Control

Open circuit

P009B73

Fuel Pressure Relief Control

The actuator jammed in the closed position

P00AF41

Performance characteristics of the turbocharger / turbocharger supercharger control module «A»

Total checksum error

P00C600

Too low pressure in the fuel distribution pipe — engine crankshaft rotation

No subtype information

P010501

Absolute pressure sensor in the manifold / barometric pressure

General electrical fault

P010512

Absolute pressure sensor in the manifold / barometric pressure

Circuit Short to Battery Voltage

P010513

Absolute pressure sensor in the manifold / barometric pressure

Open circuit

P010562

Absolute pressure sensor in the manifold / barometric pressure

Signal comparison error

P011001

Intake air temperature sensor 1, row 1

General electrical fault

P011011

Intake air temperature sensor 1, row 1

Short to ground

P011013

Intake air temperature sensor 1, row 1

Open circuit

P011501

Engine Coolant Temperature Sensor 1

General electrical fault

P011511

Engine Coolant Temperature Sensor 1

Short to ground

P011513

Engine Coolant Temperature Sensor 1

Open circuit

P01152A

Engine Coolant Temperature Sensor 1

Stuck signal in the range

P012011

Throttle / Pedal Position Sensor «A»

Short to ground

P012012

Throttle / Pedal Position Sensor «A»

Circuit Short to Battery Voltage

P012800

Coolant thermostat (coolant temperature below the thermostat control temperature)

No subtype information

P016800

Fuel temperature in engine too high

No subtype information

P016E00

Control of the fuel pressure in a closed loop at the limit is too high a pressure

No subtype information

P016F00

Controlling the fuel pressure in a closed loop at the limit is too low a pressure

No subtype information

P018501

Fuel temperature sensor «B»

General electrical fault

P018511

Fuel temperature sensor «B»

Short to ground

P018513

Fuel temperature sensor «B»

Open circuit

P018564

Fuel temperature sensor «B»

Violation of signal reliability

P019001

Pressure sensor in the fuel distributor pipe, row 1

General electrical fault

P019011

Pressure sensor in the fuel distributor pipe, row 1

Short to ground

P019013

Pressure sensor in the fuel distributor pipe, row 1

Open circuit

P019062

Pressure sensor in the fuel distributor pipe, row 1

Signal comparison error

P019064

Pressure sensor in the fuel distributor pipe, row 1

Violation of signal reliability

P019511

Engine oil temperature sensor «A»

Short to ground

P019513

Engine oil temperature sensor «A»

Open circuit

P019564

Engine oil temperature sensor «A»

Violation of signal reliability

P01B901

Engine oil temperature sensor «B»

General electrical fault

P01B911

Engine oil temperature sensor «B»

Short to ground

P01B913

Engine oil temperature sensor «B»

Open circuit

P020111

Cylinder 1 nozzle «A»

Short to ground

P020112

Cylinder 1 nozzle «A»

Circuit Short to Battery Voltage

P020113

Cylinder 1 nozzle «A»

Open circuit

P020156

Cylinder 1 nozzle «A»

Invalid / incompatible configuration

P020211

Cylinder 2 injector «A»

Short to ground

P020212

Cylinder 2 injector «A»

Circuit Short to Battery Voltage

P020213

Cylinder 2 injector «A»

Open circuit

P020256

Cylinder 2 injector «A»

Invalid / incompatible configuration

P020311

Cylinder 3 injector «A»

Short to ground

P020312

Cylinder 3 injector «A»

Circuit Short to Battery Voltage

P020313

Cylinder 3 injector «A»

Open circuit

P020356

Cylinder 3 injector «A»

Invalid / incompatible configuration

P020411

Cylinder 4 nozzle «A»

Short to ground

P020412

Cylinder 4 nozzle «A»

Circuit Short to Battery Voltage

P020413

Cylinder 4 nozzle «A»

Open circuit

P020456

Cylinder 4 nozzle «A»

Invalid / incompatible configuration

P020511

Cylinder 5 injector «A»

Short to ground

P020512

Cylinder 5 injector «A»

Circuit Short to Battery Voltage

P020513

Cylinder 5 injector «A»

Open circuit

P020556

Cylinder 5 injector «A»

Invalid / incompatible configuration

P020611

Cylinder 6 nozzle «A»

Short to ground

P020612

Cylinder 6 nozzle «A»

Circuit Short to Battery Voltage

P020613

Cylinder 6 nozzle «A»

Open circuit

P020656

Cylinder 6 nozzle «A»

Invalid / incompatible configuration

P021700

Engine coolant temperature exceeded status

No subtype information

P021800

The condition of the transmission oil temperature rise

No subtype information

P021900

State of excess of engine speed

No subtype information

P023400

Overcharging state of turbocharger / supercharger

No subtype information

P024311

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Short to ground

P024312

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Circuit Short to Battery Voltage

P024313

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Open circuit

P025612

Fuel Injector Diesel Injector

Circuit Short to Battery Voltage

P025614

Fuel Injector Diesel Injector

Short to ground or open

P025692

Fuel Injector Diesel Injector

Characteristics or malfunctioning

P026A00

The efficiency of the charge air cooler is below the threshold

No subtype information

P029800

Excess temperature of engine oil

No subtype information

P029900

Insufficient supercharging of the turbocharger / supercharger

No subtype information

P02CC00

Fuel injector cylinder 1 — determination of the correction at the minimum limit

No subtype information

P02CD00

Fuel injector cylinder 1 — determination of the correction at the maximum limit

No subtype information

P02CE00

Fuel injector cylinder 2 — determination of the correction at the minimum limit

No subtype information

P02CF00

Fuel injector cylinder 2 — determination of the correction at the maximum limit

No subtype information

P02D000

Fuel injector cylinder 3 — determination of the correction at the minimum limit

No subtype information

P02D100

Fuel injector cylinder 3 — determination of the correction at the maximum limit

No subtype information

P02D200

Fuel injector of the cylinder 4 — determination of the correction at the minimum limit

No subtype information

P02D300

Fuel injector cylinder 4 — determination of the correction at the maximum limit

No subtype information

P02D400

Fuel injector cylinder 5 — determination of the correction at the minimum limit

No subtype information

P02D500

Fuel injector cylinder 5 — determination of the correction at the maximum limit

No subtype information

P02D600

Fuel injector of the cylinder 6 — determination of the correction at the minimum limit

No subtype information

P02D700

Fuel injector of the cylinder 6 — determination of the correction at the maximum limit

No subtype information

P02E011

Airflow control at the diesel engine inlet

Short to ground

P02E012

Airflow control at the diesel engine inlet

Circuit Short to Battery Voltage

P02E013

Airflow control at the diesel engine inlet

Open circuit

P02E07C

Airflow control at the diesel engine inlet

Slow reaction

P02E09B

Airflow control at the diesel engine inlet

High / excessive flow

P02E09C

Airflow control at the diesel engine inlet

Low / insufficient flow

P02E601

Diesel Engine Admission Regulator Position Sensor

General electrical fault

P02E612

Diesel Engine Admission Regulator Position Sensor

Circuit Short to Battery Voltage

P02E613

Diesel Engine Admission Regulator Position Sensor

Open circuit

P02E697

Diesel Engine Admission Regulator Position Sensor

The operation of the component or system is difficult or blocked

P02E699

Diesel Engine Admission Regulator Position Sensor

Parameter limit exceeded

P03351F

Crankshaft Position Sensor «A»

Intermittent signal in the circuit

P033531

Crankshaft Position Sensor «A»

Missing signal

P033538

Crankshaft Position Sensor «A»

Incorrect signal frequency

P034031

Camshaft position sensor «A» — row 1 or separate sensor

Missing signal

P034038

Camshaft position sensor «A» — row 1 or separate sensor

Incorrect signal frequency

P04007C

Exhaust gas recirculation flow «A»

Slow reaction

P04009B

Exhaust gas recirculation flow «A»

High / excessive flow

P04009C

Exhaust gas recirculation flow «A»

Low / insufficient flow

P040311

Control of EGR «A»

Short to ground

P040312

Control of EGR «A»

Circuit Short to Battery Voltage

P040313

Control of EGR «A»

Open circuit

P040341

Control of EGR «A»

Total checksum error

P040371

Control of EGR «A»

Driven drive

P040392

Control of EGR «A»

Characteristics or malfunctioning

P040901

The differential pressure sensor EGR

General electrical fault

P040912

The differential pressure sensor EGR

Circuit Short to Battery Voltage

P040913

The differential pressure sensor EGR

Open circuit

P040964

The differential pressure sensor EGR

Violation of signal reliability

P040A01

Temperature sensor «A» of the exhaust gas recirculation system

General electrical fault

P040A11

Temperature sensor «A» of the exhaust gas recirculation system

Short to ground

P040A13

Temperature sensor «A» of the exhaust gas recirculation system

Open circuit

P040A64

Temperature sensor «A» of the exhaust gas recirculation system

Violation of signal reliability

P041A11

Temperature sensor circuit «B» of the exhaust gas recirculation system

Short to ground

P041A12

Temperature sensor circuit «B» of the exhaust gas recirculation system

Circuit Short to Battery Voltage

P041A2A

Temperature sensor circuit «B» of the exhaust gas recirculation system

Stuck signal in the range

P042000

The efficiency of the catalyst system is below the threshold

No subtype information

P047001

The gauge of pressure of exhaust gases «A»

General electrical fault

P047012

The gauge of pressure of exhaust gases «A»

Circuit Short to Battery Voltage

P047013

The gauge of pressure of exhaust gases «A»

Open circuit

P047064

The gauge of pressure of exhaust gases «A»

Violation of signal reliability

P047511

Exhaust Pressure Control Valve «A»

Short to ground

P047512

Exhaust Pressure Control Valve «A»

Circuit Short to Battery Voltage

P047513

Exhaust Pressure Control Valve «A»

Open circuit

P047572

Exhaust Pressure Control Valve «A»

The actuator jammed in the open position

P048011

Fan control circuit 1

Short to ground

P048012

Fan control circuit 1

Circuit Short to Battery Voltage

P048013

Fan control circuit 1

Open circuit

P048613

Sensor «B» of the EGR system

Open circuit

P049D99

Control position «A» EGR exceeded the threshold of training

Parameter limit exceeded

P04D900

Control of the closed loop EGR system at the limit — the flow is too small

No subtype information

P04DA00

Control of the closed loop EGR system at the limit — the flow is too strong

No subtype information

P050011

Vehicle speed by wheel

Short to ground

P050013

Vehicle speed by wheel

Open circuit

P051A01

Crankcase Pressure Sensor

General electrical fault

P051A12

Crankcase Pressure Sensor

Circuit Short to Battery Voltage

P051A13

Crankcase Pressure Sensor

Open circuit

P051A64

Crankcase Pressure Sensor

Violation of signal reliability

P052001

Engine oil pressure switch / relay «A»

General electrical fault

P052012

Engine oil pressure switch / relay «A»

Circuit Short to Battery Voltage

P052013

Engine oil pressure switch / relay «A»

Open circuit

P052064

Engine oil pressure switch / relay «A»

Violation of signal reliability

P052400

Engine oil pressure too low

Engine oil pressure too low

P052607

Fan Speed ​​Sensor Circuit

Mechanical faults

P052612

Fan Speed ​​Sensor Circuit

Circuit Short to Battery Voltage

P053E00

Crankcase pressure — too high

No subtype information

P054001

Control of the inlet air heater «A»

General electrical fault

P054011

Control of the inlet air heater «A»

Short to ground

P054013

Control of the inlet air heater «A»

Open circuit

P054070

Control of the inlet air heater «A»

Drive stuck when on

P05407F

Control of the inlet air heater «A»

Drive stuck when turned off

P054464

Exhaust temperature sensor — Row 1 Sensor 1

Violation of signal reliability

P055A01

Engine oil pressure switch / relay «B»

General electrical fault

P055A12

Engine oil pressure switch / relay «B»

Circuit Short to Battery Voltage

P055A13

Engine oil pressure switch / relay «B»

Open circuit

P055A64

Engine oil pressure switch / relay «B»

Violation of signal reliability

P055F00

Engine oil pressure out of range

No subtype information

P05E311

Parking brake sensor / switch circuit

Short to ground

P05E362

Parking brake sensor / switch circuit

Signal comparison error

P05E364

Parking brake sensor / switch circuit

Violation of signal reliability

P061511

Starter relay

Short to ground

P061512

Starter relay

Circuit Short to Battery Voltage

P061513

Starter relay

Open circuit

P06279C

Fuel pump control «A»

Low / insufficient flow

P064111

Sensor reference voltage «A»

Short to ground

P064112

Sensor reference voltage «A»

Circuit Short to Battery Voltage

P06411C

Sensor reference voltage «A»

Output from the voltage range in the circuit

P065111

Sensor reference voltage «V»

Short to ground

P066601

Internal temperature sensor for control module «A»

General electrical fault

P066611

Internal temperature sensor for control module «A»

Short to ground

P06B016

Sensor supply voltage «A»

Voltage in the circuit below the threshold

P06B017

Sensor supply voltage «A»

Voltage in the circuit above the threshold

P06B316

Sensor supply «B»

Voltage in the circuit below the threshold

P06B317

Sensor supply «B»

Voltage in the circuit above the threshold

P06DA71

Engine Oil Pressure Adjustment

Driven drive

P06E616

Sensor supply voltage «C»

Voltage in the circuit below the threshold

P06E617

Sensor supply voltage «C»

Voltage in the circuit above the threshold

P073021

Recommended transfer

The amplitude of the signal is less than the minimum

P073022

Recommended transfer

The amplitude of the signal above the maximum value

P07307C

Recommended transfer

Slow reaction

P100101

Engine stop switch

General electrical fault

P100111

Engine stop switch

Short to ground

P100112

Engine stop switch

Circuit Short to Battery Voltage

P100190

Engine stop switch

Clogged in the open position

P100192

Engine stop switch

Characteristics or malfunctioning

P100211

Pre-heater heater relay

Short to ground

P100212

Pre-heater heater relay

Circuit Short to Battery Voltage

P100213

Pre-heater heater relay

Open circuit

P100701

Air filter indicator

General electrical fault

P100711

Air filter indicator

Short to ground

P100712

Air filter indicator

Circuit Short to Battery Voltage

P100713

Air filter indicator

Open circuit

P101711

Valve for draining water from fuel

Short to ground

P101E11

The valve of full blocking of the channel of a transmission

Short to ground

P101E12

The valve of full blocking of the channel of a transmission

Circuit Short to Battery Voltage

P101E13

The valve of full blocking of the channel of a transmission

Open circuit

P102111

Volvo Compression Brake Control Circuit (VCB)

Short to ground

P102112

Volvo Compression Brake Control Circuit (VCB)

Circuit Short to Battery Voltage

P102113

Volvo Compression Brake Control Circuit (VCB)

Open circuit

P108600

The oil level is moderately low

No subtype information

P109300

Engine oil pressure is moderately low

No subtype information

P10C011

Volvo Compression Brake Control Circuit (VCB) «2»

Short to ground

P10C012

Volvo Compression Brake Control Circuit (VCB) «2»

Circuit Short to Battery Voltage

P10C013

Volvo Compression Brake Control Circuit (VCB) «2»

Open circuit

P10E100

Differential pressure in particulate filter is critical

No subtype information

P10E200

Differential pressure on particulate filter moderately high

No subtype information

P10F800

Air filter clogged

No subtype information

P10FE00

Clogging of particulate filter — soot accumulation moderately high — row 1

No subtype information

P110400

Factory setting

No subtype information

P110501

Back-up switch circuit «A» of the engine

General electrical fault

P110511

Back-up switch circuit «A» of the engine

Short to ground

P110512

Back-up switch circuit «A» of the engine

Circuit Short to Battery Voltage

P110573

Back-up switch circuit «A» of the engine

The actuator jammed in the closed position

P111600

Absolute pressure sensor in the reservoir is a moderate excess

No subtype information

P111800

Absolute pressure sensor in the collector — a strong excess

No subtype information

P111945

The intake manifold temperature is too high at a moderate level

Failure of program memory

P111A00

Intake manifold temperature too high

No subtype information

P111D00

The engine coolant level is moderately low

No subtype information

P111E00

Engine coolant temperature is moderately high

No subtype information

P112500

Engine oil temperature — moderately high

No subtype information

P112800

The oil pressure for cooling the pistons is moderately low

No subtype information

P112900

Transmission oil temperature moderately high

No subtype information

P112B00

The turbocharger / turbocharger drive temperature «A»

No subtype information

P112E00

Exhaust gas temperature moderately high — row 1

No subtype information

P113411

Air purge valve for fuel injection into the exhaust aftertreatment system

Short to ground

P113413

Air purge valve for fuel injection into the exhaust aftertreatment system

Open circuit

P113472

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the open position

P113473

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the closed position

P113500

Crankcase pressure too high relative to atmospheric pressure

No subtype information

P113600

Error of calibration of the correlation of NOx 1/2 sensors — row 1

No subtype information

P113711

Oil thermostat

Short to ground

P113712

Oil thermostat

Circuit Short to Battery Voltage

P113713

Oil thermostat

Open circuit

P113F11

Idling switch confirmation cable with buffering — VECU side

Short to ground

P113F12

Idling switch confirmation cable with buffering — VECU side

Circuit Short to Battery Voltage

P114000

Volvo Compression Brake Control (VCB) — too low oil temperature

No subtype information

P114101

Idling switch confirmation cable with buffering — ECM side

General electrical fault

P114113

Idling switch confirmation cable with buffering — ECM side

Open circuit

P114123

Idling switch confirmation cable with buffering — ECM side

Constantly low signal level

P114124

Idling switch confirmation cable with buffering — ECM side

Constantly high signal level

P114411

High voltage side of the starter relay

Short to ground

P114412

High voltage side of the starter relay

Circuit Short to Battery Voltage

P114413

High voltage side of the starter relay

Open circuit

P114500

The level of the reducing agent is moderately low

No subtype information

P114700

Pressure in the fuel distribution pipe / system, row 1 — moderately too high

No subtype information

P114B00

The turbocharger / turbocharger drive temperature «A» is too low

No subtype information

P114E00

EGR drive temperature outside the operating range

No subtype information

P115000

Correlation of Sensor / Switch Voltage «A» / «D» Throttle Position / Pedal Position

No subtype information

P115100

Excess temperature of the post-treatment system

No subtype information

P115211

Starting fuel pump

Short to ground

P115212

Starting fuel pump

Circuit Short to Battery Voltage

P115213

Starting fuel pump

Open circuit

P115400

The connection between the bodywork control module «A» and the instrument cluster control module (IPC)

No subtype information

P117311

Low Transmission Range Authorization Valve

Short to ground

P117312

Low Transmission Range Authorization Valve

Circuit Short to Battery Voltage

P117313

Low Transmission Range Authorization Valve

Open circuit

P117401

Transmission range inquiry

General electrical fault

P117411

Transmission range inquiry

Short to ground

P117412

Transmission range inquiry

Circuit Short to Battery Voltage

P117600

Starter motor is deactivated — temperature rise

No subtype information

P117700

Starter motor is deactivated — gearbox is not in neutral position

No subtype information

P117800

The starter motor is deactivated — the gear of the electric motor of the starter motor is stuck

No subtype information

P117900

Starter motor is deactivated — power take-off is active

No subtype information

P117B01

Temperature sensor switch in engine compartment

General electrical fault

P117B11

Temperature sensor switch in engine compartment

Short to ground

P117B12

Temperature sensor switch in engine compartment

Circuit Short to Battery Voltage

P117C00

The requested range of gears is too high

No subtype information

P117D00

Requested driver transfer too low

No subtype information

P117E00

Driver’s request is too high

No subtype information

P117F11

Bypass valve of the hydraulic valve

Short to ground

P117F12

Bypass valve of the hydraulic valve

Circuit Short to Battery Voltage

P117F13

Bypass valve of the hydraulic valve

Open circuit

P203164

Exhaust temperature sensor — Row 1 Sensor 2

Violation of signal reliability

P203A86

Reagent level sensor «A»

Invalid signal

P203F00

Reducer level is low

No subtype information

P204F93

Characteristics of the SCR system — dosing failure

Does not work

P207F9A

Quality of the reducing agent

Working conditions of a component or system

P20D711

Controlling the fuel supply to the exhaust aftertreatment system

Short to ground

P20D713

Controlling the fuel supply to the exhaust aftertreatment system

Open circuit

P20D773

Controlling the fuel supply to the exhaust aftertreatment system

The actuator jammed in the closed position

P20DD01

Fuel pressure sensor for exhaust gas aftertreatment

General electrical fault

P20DD12

Fuel pressure sensor for exhaust gas aftertreatment

Circuit Short to Battery Voltage

P20DD13

Fuel pressure sensor for exhaust gas aftertreatment

Open circuit

P20EE00

The efficiency of the SCR NOx catalyst is below the threshold (row 1)

No subtype information

P20F400

AdBlue consumption is too low

No subtype information

P20F500

Reducer consumption too high

No subtype information

P210900

Performance characteristics of the «A» minimum limiter of the throttle / pedal position

No subtype information

P213600

Correlation of Sensor / Switch Voltage «A» / «C» Throttle Position / Pedal Position

No subtype information

P215A62

Correlation of vehicle speed with wheel speed

Signal comparison error

P215A64

Correlation of vehicle speed with wheel speed

Violation of signal reliability

P216300

Performance characteristics of the maximum limit sensor «A» of the throttle / pedal position

No subtype information

P220012

NOx sensor — series 1 sensor 1

Circuit Short to Battery Voltage

P220013

NOx sensor — series 1 sensor 1

Open circuit

P22001C

NOx sensor — series 1 sensor 1

Output from the voltage range in the circuit

P220064

NOx sensor — series 1 sensor 1

Violation of signal reliability

P220093

NOx sensor — series 1 sensor 1

Does not work

P222601

Barometric pressure circuit

General electrical fault

P222612

Barometric pressure circuit

Circuit Short to Battery Voltage

P222613

Barometric pressure circuit

Open circuit

P222664

Barometric pressure circuit

Violation of signal reliability

P225C00

Characteristics of the NOx sensor — high level signaling — row 1 sensor 1

No subtype information

P225D00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 1

No subtype information

P225E67

Characteristics of the NOx sensor — high level signaling — row 1 sensor 2

Wrong signal after event

P225F00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 2

No subtype information

P226401

Water sensor in fuel

General electrical fault

P226411

Water sensor in fuel

Short to ground

P226413

Water sensor in fuel

Open circuit

P228D72

The fuel pressure regulator 1 has exceeded the control limits — too high a pressure

The actuator jammed in the open position

P228E00

The fuel pressure regulator 1 has exceeded the training limits — too low a pressure

No subtype information

P228F00

The fuel pressure regulator 1 has exceeded the training limits — too high a pressure

No subtype information

P229E12

NOx sensor — row 1 sensor 2

Circuit Short to Battery Voltage

P229E13

NOx sensor — row 1 sensor 2

Open circuit

P229E1C

NOx sensor — row 1 sensor 2

Output from the voltage range in the circuit

P229E64

NOx sensor — row 1 sensor 2

Violation of signal reliability

P229E93

NOx sensor — row 1 sensor 2

Does not work

P22FB92

Sensor Specifications NOx — Sensor — Row 1 Sensor 1

Characteristics or malfunctioning

P22FE00

Sensor Specifications NOx — Sensor — Row 1 Sensor 2

No subtype information

P242800

Exhaust gas temperature too high

No subtype information

P242A64

Exhaust temperature sensor — Row 1 Sensor 3

Violation of signal reliability

P244A00

Differential pressure on the diesel particulate filter after-treatment 1 is too small (row 1)

No subtype information

P244B00

The differential pressure on the diesel particulate filter after-treatment 1 is too large (row 1)

No subtype information

P244C00

The exhaust gas temperature is too low to regenerate the particulate filter (row 1)

No subtype information

P245264

Particulate filter pressure sensor «A»

Violation of signal reliability

P245700

Coolant efficiency of the exhaust gas recirculation system is below the threshold value

No subtype information

P246300

Clogged particulate filter — soot accumulation — row 1

No subtype information

P249D00

Control of the injection of the reducing agent in a closed loop at the limit — the flow is too small

No subtype information

P249E00

Injection of the reducing agent in a closed loop at the limit — the flow is too high

No subtype information

P249F92

Excessive time for switching to the closed-loop diesel particulate filter regeneration control mode

Characteristics or malfunctioning

P24A000

Control of DPF regeneration in a closed loop at the limit — the temperature is too low

No subtype information

P24A100

Control of DPF regeneration in a closed loop at the limit — the temperature is too high

No subtype information

P24A200

The regeneration of the diesel particulate filter is not complete (row 1)

No subtype information

P24A400

Clogging of the diesel particulate filter — soot accumulation too large (row 1)

No subtype information

P250A11

Engine oil level sensor

Short to ground

P250A13

Engine oil level sensor

Open circuit

P250F00

Engine oil level too low

No subtype information

P253901

Low Fuel Pressure Sensor Circuit

General electrical fault

P253912

Low Fuel Pressure Sensor Circuit

Circuit Short to Battery Voltage

P253913

Low Fuel Pressure Sensor Circuit

Open circuit

P255601

Engine Coolant Level Sensor / Relay

General electrical fault

P255611

Engine Coolant Level Sensor / Relay

Short to ground

P255612

Engine Coolant Level Sensor / Relay

Circuit Short to Battery Voltage

P255613

Engine Coolant Level Sensor / Relay

Open circuit

P256000

Engine Coolant Level — Low

No subtype information

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P259C00

Excessive time for entering the supercharging control of the turbocharger «A» in a closed loop

No subtype information

P25A911

Control oil supply for cooling pistons

Short to ground

P25A912

Control oil supply for cooling pistons

Circuit Short to Battery Voltage

P25A913

Control oil supply for cooling pistons

Open circuit

P25A971

Control oil supply for cooling pistons

Driven drive

P25AE00

The oil pressure for cooling the pistons is too low

No subtype information

P260011

Coolant Pump Control Circuit / Break

Short to ground

P260012

Coolant Pump Control Circuit / Break

Circuit Short to Battery Voltage

P260013

Coolant Pump Control Circuit / Break

Open circuit

P268111

Control of the bypass valve «A» of the engine coolant

Short to ground

P268112

Control of the bypass valve «A» of the engine coolant

Circuit Short to Battery Voltage

P268113

Control of the bypass valve «A» of the engine coolant

Open circuit

P269711

Injection Fuel Injector «A»

Short to ground

P269713

Injection Fuel Injector «A»

Open circuit

P269773

Injection Fuel Injector «A»

The actuator jammed in the closed position

P26977A

Injection Fuel Injector «A»

Fluid leakage or seal failure

P2A1612

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Circuit Short to Battery Voltage

P2A1614

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Short to ground or open

P2A1692

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Characteristics or malfunctioning

P2A1E12

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Circuit Short to Battery Voltage

P2A1E14

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Short to ground or open

P2A1E92

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Characteristics or malfunctioning

U000188

CAN Backbone bus 2 communication network

Bus Off

U001088

CAN Backbone bus 1 of the communication network

Bus Off

U008088

Communication Subnet of the car engine

Bus Off

U010100

Lost Communication With TECU

No subtype information

U010A00

Lost communication with the A module of the exhaust gas recirculation system

No subtype information

U010C00

The communication with the turbocharger / supercharger control module is broken

No subtype information

U012100

The communication with the anti-lock braking system (ABS)

No subtype information

U012900

Lost Communication With Brake Control Module

No subtype information

U014100

Lost connection with VMCU

No subtype information

U014200

Lost connection with the body control module «B»

No subtype information

U015500

Communication with the instrument cluster control module (IPC) is broken

No subtype information

U016700

Lost communication with the car immobilizer control module

No subtype information

U029D00

Communication with NOx sensor «A» is broken

No subtype information

U029E00

The communication with the NOx sensor «B» is broken

No subtype information

U032300

Software incompatibility with the dashboard control module

No subtype information

U033100

Incompatibility of software with the bodywork control module «A»

No subtype information

U042600

From the immobilizer control module of the car, unreliable data

No subtype information

U116600

Lost communication with CIOM

No subtype information

U116900

Lost connection with DACU

No subtype information

U116B00

Communication with TCM on the high-speed communication bus CAN

No subtype information

U116C00

Communication with TCM on the CAN bus of the power plant is broken

No subtype information

U116F00

Communication with the control module of the supply of the reducing agent via the engine subnetwork is broken

No subtype information

U117100

The communication with the control unit of the body equipment via the high-speed communication bus CAN

No subtype information

U117300

The communication with the IPC control unit via the high-speed communication CAN

No subtype information

U117888

CAN bus communication system bus

Bus Off

U1FFF68

Factory mode active

Event details

U300001

Electronic control module

General electrical fault

U300041

Electronic control module

Total checksum error

U300044

Electronic control module

Data memory failure

U300045

Electronic control module

Failure of program memory

U300049

Electronic control module

Internal failure of electronics

U300257

Vehicle Identification Number

Invalid / incompatible software component

TECU, диагностические коды неисправности

Диагностический код неисправности Название кода DTC Тип неисправности
P105017 Датчик положения демультипликатора (SEPoR) Напряжение в цепи выше порога
P105018 Датчик положения демультипликатора (SEPoR) Ток в цепи ниже пороговой величины
P105019 Датчик положения демультипликатора (SEPoR) Ток в цепи выше порога
P105054 Датчик положения демультипликатора (SEPoR) Отсутствует калибровка
P105117 Датчик положения делителя (SEPoS) Напряжение в цепи выше порога
P105118 Датчик положения делителя (SEPoS) Ток в цепи ниже пороговой величины
P105119 Датчик положения делителя (SEPoS) Ток в цепи выше порога
P105154 Датчик положения делителя (SEPoS) Отсутствует калибровка
P105217 Положение цилиндра сцепления Напряжение в цепи выше порога
P105218 Положение цилиндра сцепления Ток в цепи ниже пороговой величины
P105229 Положение цилиндра сцепления Недопустимый сигнал
P105254 Положение цилиндра сцепления Отсутствует калибровка
P105262 Положение цилиндра сцепления Ошибка сравнения сигнала
P105378 Износ диска сцепления Неверная юстировка или регулировка
P105417 Датчик давления воздуха в баке (SEPrSA) Напряжение в цепи выше порога
P105418 Датчик давления воздуха в баке (SEPrSA) Ток в цепи ниже пороговой величины
P105421 Датчик давления воздуха в баке (SEPrSA) Амплитуда сигнала меньше минимума
P105422 Датчик давления воздуха в баке (SEPrSA) Амплитуда сигнала выше максимальной величины
P105594 Выключатель тормоза, состояние Неожиданная операция
P105716 Датчик скорости главного вала (SESM) Напряжение в цепи ниже порога
P105717 Датчик скорости главного вала (SESM) Напряжение в цепи выше порога
P105718 Датчик скорости главного вала (SESM) Ток в цепи ниже пороговой величины
P105721 Датчик скорости главного вала (SESM) Амплитуда сигнала меньше минимума
P105729 Датчик скорости главного вала (SESM) Недопустимый сигнал
P105816 Датчик скорости промежуточного вала (SESC) Напряжение в цепи ниже порога
P105817 Датчик скорости промежуточного вала (SESC) Напряжение в цепи выше порога
P105818 Датчик скорости промежуточного вала (SESC) Ток в цепи ниже пороговой величины
P105821 Датчик скорости промежуточного вала (SESC) Амплитуда сигнала меньше минимума
P105916 Датчик температуры масла в коробке передач (SETeGO) Напряжение в цепи ниже порога
P105918 Датчик температуры масла в коробке передач (SETeGO) Ток в цепи ниже пороговой величины
P105922 Датчик температуры масла в коробке передач (SETeGO) Амплитуда сигнала выше максимальной величины
P105992 Датчик температуры масла в коробке передач (SETeGO) Характеристики или неправильное функционирование
P105998 Датчик температуры масла в коробке передач (SETeGO) Перегрев компонента или системы
P105A17 Клапан повышенного ряда (VAHR) Напряжение в цепи выше порога
P105A18 Клапан повышенного ряда (VAHR) Ток в цепи ниже пороговой величины
P105A19 Клапан повышенного ряда (VAHR) Ток в цепи выше порога
P105B17 Клапан пониженного ряда (VALR) Напряжение в цепи выше порога
P105B18 Клапан пониженного ряда (VALR) Ток в цепи ниже пороговой величины
P105B19 Клапан пониженного ряда (VALR) Ток в цепи выше порога
P105C17 Клапан прямого делителя (VADS) Напряжение в цепи выше порога
P105C18 Клапан прямого делителя (VADS) Ток в цепи ниже пороговой величины
P105C19 Клапан прямого делителя (VADS) Ток в цепи выше порога
P105D17 Клапан непрямого делителя (VAIDS) Напряжение в цепи выше порога
P105D18 Клапан непрямого делителя (VAIDS) Ток в цепи ниже пороговой величины
P105D19 Клапан непрямого делителя (VAIDS) Ток в цепи выше порога
P105E17 Датчик положения переключателя 1 (SEPo1R) Напряжение в цепи выше порога
P105E18 Датчик положения переключателя 1 (SEPo1R) Ток в цепи ниже пороговой величины
P105E19 Датчик положения переключателя 1 (SEPo1R) Ток в цепи выше порога
P105E54 Датчик положения переключателя 1 (SEPo1R) Отсутствует калибровка
P105F17 Датчик положения переключателя 2 (SEPo23) Напряжение в цепи выше порога
P105F18 Датчик положения переключателя 2 (SEPo23) Ток в цепи ниже пороговой величины
P105F19 Датчик положения переключателя 2 (SEPo23) Ток в цепи выше порога
P105F54 Датчик положения переключателя 2 (SEPo23) Отсутствует калибровка
P106063 Нагрузка диска сцепления Тайм-аут защиты цепи/компонента
P106074 Нагрузка диска сцепления Проскальзывание исполнительного механизма
P106093 Нагрузка диска сцепления Не функционирует
P106094 Нагрузка диска сцепления Неожиданная операция
P106154 Положение точки проскальзывания цилиндра сцепления Отсутствует калибровка
P106216 Питание датчика положения сцепления (SEPoC5V) Напряжение в цепи ниже порога
P106218 Питание датчика положения сцепления (SEPoC5V) Ток в цепи ниже пороговой величины
P106329 Датчик наклона коробки передач (SEIG) Недопустимый сигнал
P106417 Клапан быстрого включения сцепления (VAFE) Напряжение в цепи выше порога
P106418 Клапан быстрого включения сцепления (VAFE) Ток в цепи ниже пороговой величины
P106419 Клапан быстрого включения сцепления (VAFE) Ток в цепи выше порога
P106517 Клапан медленного включения сцепления (VASE) Напряжение в цепи выше порога
P106518 Клапан медленного включения сцепления (VASE) Ток в цепи ниже пороговой величины
P106519 Клапан медленного включения сцепления (VASE) Ток в цепи выше порога
P106617 Клапан быстрого выключения сцепления (VAFD) Напряжение в цепи выше порога
P106618 Клапан быстрого выключения сцепления (VAFD) Ток в цепи ниже пороговой величины
P106619 Клапан быстрого выключения сцепления (VAFD) Ток в цепи выше порога
P106717 Клапан медленного выключения сцепления (VASD) Напряжение в цепи выше порога
P106718 Клапан медленного выключения сцепления (VASD) Ток в цепи ниже пороговой величины
P106719 Клапан медленного выключения сцепления (VASD) Ток в цепи выше порога
P106A17 Клапан 1 передачи (VAG1) Напряжение в цепи выше порога
P106A18 Клапан 1 передачи (VAG1) Ток в цепи ниже пороговой величины
P106A19 Клапан 1 передачи (VAG1) Ток в цепи выше порога
P106B17 Клапан задней передачи (VAGR) Напряжение в цепи выше порога
P106B18 Клапан задней передачи (VAGR) Ток в цепи ниже пороговой величины
P106B19 Клапан задней передачи (VAGR) Ток в цепи выше порога
P106C17 Клапан 2 передачи (VAG2) Напряжение в цепи выше порога
P106C18 Клапан 2 передачи (VAG2) Ток в цепи ниже пороговой величины
P106C19 Клапан 2 передачи (VAG2) Ток в цепи выше порога
P106D17 Клапан 3 передачи (VAG3) Напряжение в цепи выше порога
P106D18 Клапан 3 передачи (VAG3) Ток в цепи ниже пороговой величины
P106D19 Клапан 3 передачи (VAG3) Ток в цепи выше порога
P107017 Клапан тормоза коробки передач (VAGB) Напряжение в цепи выше порога
P107018 Клапан тормоза коробки передач (VAGB) Ток в цепи ниже пороговой величины
P107019 Клапан тормоза коробки передач (VAGB) Ток в цепи выше порога
P107177 Система включения делителя Требуемое положение недостижимо
P107179 Система включения делителя Неисправность механического рычажного механизма
P107192 Система включения делителя Характеристики или неправильное функционирование
P107194 Система включения делителя Неожиданная операция
P107196 Система включения делителя Внутренний отказ компонента
P107197 Система включения делителя Функционирование компонента или системы затруднено или заблокировано
P107277 Система включения демультипликатора Требуемое положение недостижимо
P107292 Система включения демультипликатора Характеристики или неправильное функционирование
P107294 Система включения демультипликатора Неожиданная операция
P107297 Система включения демультипликатора Функционирование компонента или системы затруднено или заблокировано
P107371 Система включения 1 и задней передач Заело привод
P107377 Система включения 1 и задней передач Требуемое положение недостижимо
P107392 Система включения 1 и задней передач Характеристики или неправильное функционирование
P107394 Система включения 1 и задней передач Неожиданная операция
P107396 Система включения 1 и задней передач Внутренний отказ компонента
P107397 Система включения 1 и задней передач Функционирование компонента или системы затруднено или заблокировано
P107471 Система включения 2 и 3 передач Заело привод
P107477 Система включения 2 и 3 передач Требуемое положение недостижимо
P107492 Система включения 2 и 3 передач Характеристики или неправильное функционирование
P107494 Система включения 2 и 3 передач Неожиданная операция
P107496 Система включения 2 и 3 передач Внутренний отказ компонента
P107497 Система включения 2 и 3 передач Функционирование компонента или системы затруднено или заблокировано
P107538 Система сцепления Неверная частота сигнала
P107554 Система сцепления Отсутствует калибровка
P107571 Система сцепления Заело привод
P107572 Система сцепления Исполнительный механизм заклинил в открытом положении
P107574 Система сцепления Проскальзывание исполнительного механизма
P107575 Система сцепления Аварийное положение недостижимо
P107577 Система сцепления Требуемое положение недостижимо
P107586 Система сцепления Недопустимый сигнал
P107592 Система сцепления Характеристики или неправильное функционирование
P107594 Система сцепления Неожиданная операция
P107694 Тормоз коробки передач Неожиданная операция
P107B86 Положение педали акселератора / характеристики сигнала выключателя тормозов Недопустимый сигнал
P109317 Цепь стороны высокого уровня клапана передачи 1 (VAG1HS) Напряжение в цепи выше порога
P109319 Цепь стороны высокого уровня клапана передачи 1 (VAG1HS) Ток в цепи выше порога
P109417 Цепь стороны высокого уровня клапана задней передачи Напряжение в цепи выше порога
P109419 Цепь стороны высокого уровня клапана задней передачи Ток в цепи выше порога
P109517 Цепь стороны высокого уровня внутреннего клапана 1 (VAIN1HS) Напряжение в цепи выше порога
P109519 Цепь стороны высокого уровня внутреннего клапана 1 (VAIN1HS) Ток в цепи выше порога
P109617 Цепь стороны высокого уровня внутреннего клапана 2 (VAIN2HS) Напряжение в цепи выше порога
P109619 Цепь стороны высокого уровня внутреннего клапана 2 (VAIN2HS) Ток в цепи выше порога
P10A017 Цепь стороны высокого уровня медленных клапанов сцепления (VASHS) Напряжение в цепи выше порога
P10A019 Цепь стороны высокого уровня медленных клапанов сцепления (VASHS) Ток в цепи выше порога
P10A117 Цепь стороны высокого уровня быстрых клапанов сцепления (VAFHS) Напряжение в цепи выше порога
P10A119 Цепь стороны высокого уровня быстрых клапанов сцепления (VAFHS) Ток в цепи выше порога
P10AE81 Включена передача в нейтральном положении Получены недопустимые данные по последовательному каналу
U000188 CAN Магистральная шина 2 коммуникационной сети Шина отключена
U001088 CAN Магистральная шина 1 коммуникационной сети Шина отключена
U007387 CAN Коммуникационная подсеть силовой установки Отсутствует сообщение
U007388 CAN Коммуникационная подсеть силовой установки Шина отключена
U010000 Потеряна связь с EMS Информация о подтипе отсутствует
U012900 Потеряна связь с модулем управления тормозной системой Информация о подтипе отсутствует
U014000 Потеряна связь с VMCU Информация о подтипе отсутствует
U030055 Программирование памяти ЭППЗУ ПО разработки Не сконфигурировано
U030081 Программирование памяти ЭППЗУ ПО разработки Получены недопустимые данные по последовательному каналу
U114100 Потеряна связь с HMIIOM Информация о подтипе отсутствует
U114286 Скорость автомобиля по колесу Недопустимый сигнал
U300017 Электронный модуль управления Напряжение в цепи выше порога
U300041 Электронный модуль управления Ошибка общей контрольной суммы
U300044 Электронный модуль управления Отказ памяти данных
U300046 Электронный модуль управления Отказ памяти калибровки/параметров
U30004B Электронный модуль управления Перегрев
U300055 Электронный модуль управления Не сконфигурировано
U300316 Питание от аккумулятора Напряжение в цепи ниже порога
U300317 Питание от аккумулятора Напряжение в цепи выше порога

and ru

Регистрация
6 Май 2023
Сообщения
3
Марка машины
Volvo
Модель Volvo
S60 II
Город
Москва
Регион
Москва

  • #1

Появились такие ошибки.
ECM-P042000
ECM-P001500
ECM-U012900
ECM-P001568

Kertman

Клубная СТО «Инавто»

Регистрация
19 февраля 2012
Сообщения
4,485
Город
Санкт-Петербург
Регион
Санкт-Петербург
Имя
Игорь

  • #2

Появились такие ошибки.
ECM-P042000
ECM-P001500
ECM-U012900
ECM-P001568

Вин авто ?

and ru

Регистрация
6 Май 2023
Сообщения
3
Марка машины
Volvo
Модель Volvo
S60 II
Город
Москва
Регион
Москва

  • #3

YV1PS61H0D2197445

добавлено сообщение

  • Club Volvo. Ru - Подскажите по ошибкам пожалуйста

    IMG-20230506-WA0020.jpg

    84.6 KB · Просмотры: 13

Kertman

Клубная СТО «Инавто»

Регистрация
19 февраля 2012
Сообщения
4,485
Город
Санкт-Петербург
Регион
Санкт-Петербург
Имя
Игорь

and ru

Регистрация
6 Май 2023
Сообщения
3
Марка машины
Volvo
Модель Volvo
S60 II
Город
Москва
Регион
Москва

  • #5

YV1FS61H0D2197445
Неправильно написал первый раз.

Kertman

Клубная СТО «Инавто»

Регистрация
19 февраля 2012
Сообщения
4,485
Город
Санкт-Петербург
Регион
Санкт-Петербург
Имя
Игорь

  • #6

284: ECM-P001500 Синхронизация положения распредвала на выпуске (В) — слишком позднее положение (ряд 1). Информация об общей ошибке. Нет информации о типе переходника, B5254T12

284: ECM-P001500 Синхронизация положения распредвала на выпуске (В) — слишком позднее положение (ряд 1). Информация об общей ошибке. Нет информации о типе переходника, B5254T12​

Печать​

J3603236

Поиск неисправности
Проверка компонентов
Примечание Если зарегистрирован код неисправности для корреляции положений коленчатого вала и распределительного вала, сначала выполните поиск неисправности для этого кода.
Информация: Загрязнения в моторном масле могут повредить компоненты системы регулировки фаз газораспределения (VVT).
Проверьте качество моторного масла. Будьте особенно внимательны к возможным загрязнениям.
Снимите регулирующий клапан распределительного вала. Проверьте клапан и масляные каналы в головке цилиндров. Проверьте на наличие загрязнений и засоров.
Если причина неполадок не обнаружена или неполадки не устраняются после принятия вышеуказанных мер, попробуйте установить новый регулирующий клапан распределительного вала.
Информация: Неполадки также могут быть причиной внутренней неисправности в системе регулировки фаз газораспределения (VVT). Если вышеуказанная процедура поиска/устранения неисправности не помогла избавиться от неполадок, возможно, их причина связана с повреждением компонентов системы регулировки фаз газораспределения (VVT).

          Volvo vehicles, like any other vehicles, also generate many unwarranted error codes. Error codes often occur in heavy duty vehicles due to high torque and high load. The error codes most frequently encountered by users are from from the Adblue system.

         When we say Adblue systems, we often think about system that breaks very easily. These systems are often used in heavy loads and commercial vehicles. Lately, it has begun to be used in passenger cars. these systems are not used in most countries, even if they are mandatory in Europe. Because it is not structured correctly. Even the adblue liquid, that this system uses, is very difficult to find on the market. Like we said, the system is unstable and users are having trouble. It is a very difficult situation when the systems breaks in the middle of road . Repair of the system is very costly and you lose precious time. For this reason, users are often looking for solutions. One of the solution is an Adblue Emulator developed by SAIL TECHNOLOGY. It is a permanent solution and will be there right beside you in every situation. Adblue Emulators, which many users prefer, will not let you down.

So what do these emulators do and what information do they give? Below are the benefits and fault code information of the SAIL Technology Adblue Emulator we have listed for you.

The instructional models are designed for: Volvo B11R (3), Volvo B5LH (3), Volvo B5TL (3), Volvo B8R (3), Volvo FH (4).

Attention: Please visit https://www.canbusemulator.com/en for more detailed information about diagnostic trouble codes

DTC

DTC Code Name

Type of malfunction

P01951F

Engine Oil Temperature Sensor «A»

Circuit Intermittent

B150413

Vision Camera 1 Heater Circuit

Circuit Open

P001676

Crankshaft Position — Correlation with Camshaft Position

Incorrect installation position

P003A99

Turbocharger / turbocharger supercharging control position «A» has exceeded the training threshold

Parameter limit exceeded

P004513

Open in turbocharger / turbocharger supercharging control circuit «A»

Open circuit

P004519

Open in turbocharger / turbocharger supercharging control circuit «A»

Current in the circuit above the threshold

P004577

Open in turbocharger / turbocharger supercharging control circuit «A»

The required position is unattainable

P004591

Open in turbocharger / turbocharger supercharging control circuit «A»

Parametric

P004592

Open in turbocharger / turbocharger supercharging control circuit «A»

Characteristics or malfunctioning

P00459A

Open in turbocharger / turbocharger supercharging control circuit «A»

Working conditions of a component or system

P006964

Correlation of absolute pressure in the reservoir and barometric pressure

Violation of signal reliability

P006E16

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit below the threshold

P006E17

Supply voltage control circuit turbocharger / turbocharger «A»

Voltage in the circuit above the threshold

P007011

Outdoor temperature sensor «A»

Short to ground

P007015

Outdoor temperature sensor «A»

Circuit short to battery voltage or break

P008700

The pressure in the fuel distribution pipe / system is too low, row 1

No subtype information

P008800

The pressure in the fuel distribution pipe / system is too high, row 1

No subtype information

P008A00

The pressure in the low-pressure fuel system is too low

No subtype information

P008B00

The pressure in the low-pressure fuel system is too high

No subtype information

P008B97

The pressure in the low-pressure fuel system is too high

The operation of the component or system is difficult or blocked

P009011

Control of fuel pressure regulator 1

Short to ground

P009012

Control of fuel pressure regulator 1

Circuit Short to Battery Voltage

P009013

Control of fuel pressure regulator 1

Open circuit

P009400

A leak in the fuel system — a small leak

No subtype information

P009A00

Air temperature at engine intake — correlation

No subtype information

P009B11

Fuel Pressure Relief Control

Short to ground

P009B12

Fuel Pressure Relief Control

Circuit Short to Battery Voltage

P009B13

Fuel Pressure Relief Control

Open circuit

P009B73

Fuel Pressure Relief Control

The actuator jammed in the closed position

P00AF41

Performance characteristics of the turbocharger / turbocharger supercharger control module «A»

Total checksum error

P00C600

Too low pressure in the fuel distribution pipe — engine crankshaft rotation

No subtype information

P010501

Absolute pressure sensor in the manifold / barometric pressure

General electrical fault

P010512

Absolute pressure sensor in the manifold / barometric pressure

Circuit Short to Battery Voltage

P010513

Absolute pressure sensor in the manifold / barometric pressure

Open circuit

P010562

Absolute pressure sensor in the manifold / barometric pressure

Signal comparison error

P011001

Intake air temperature sensor 1, row 1

General electrical fault

P011011

Intake air temperature sensor 1, row 1

Short to ground

P011013

Intake air temperature sensor 1, row 1

Open circuit

P011501

Engine Coolant Temperature Sensor 1

General electrical fault

P011511

Engine Coolant Temperature Sensor 1

Short to ground

P011513

Engine Coolant Temperature Sensor 1

Open circuit

P01152A

Engine Coolant Temperature Sensor 1

Stuck signal in the range

P012011

Throttle / Pedal Position Sensor «A»

Short to ground

P012012

Throttle / Pedal Position Sensor «A»

Circuit Short to Battery Voltage

P012800

Coolant thermostat (coolant temperature below the thermostat control temperature)

No subtype information

P016800

Fuel temperature in engine too high

No subtype information

P016E00

Control of the fuel pressure in a closed loop at the limit is too high a pressure

No subtype information

P016F00

Controlling the fuel pressure in a closed loop at the limit is too low a pressure

No subtype information

P018501

Fuel temperature sensor «B»

General electrical fault

P018511

Fuel temperature sensor «B»

Short to ground

P018513

Fuel temperature sensor «B»

Open circuit

P018564

Fuel temperature sensor «B»

Violation of signal reliability

P019001

Pressure sensor in the fuel distributor pipe, row 1

General electrical fault

P019011

Pressure sensor in the fuel distributor pipe, row 1

Short to ground

P019013

Pressure sensor in the fuel distributor pipe, row 1

Open circuit

P019062

Pressure sensor in the fuel distributor pipe, row 1

Signal comparison error

P019064

Pressure sensor in the fuel distributor pipe, row 1

Violation of signal reliability

P019511

Engine oil temperature sensor «A»

Short to ground

P019513

Engine oil temperature sensor «A»

Open circuit

P019564

Engine oil temperature sensor «A»

Violation of signal reliability

P01B901

Engine oil temperature sensor «B»

General electrical fault

P01B911

Engine oil temperature sensor «B»

Short to ground

P01B913

Engine oil temperature sensor «B»

Open circuit

P020111

Cylinder 1 nozzle «A»

Short to ground

P020112

Cylinder 1 nozzle «A»

Circuit Short to Battery Voltage

P020113

Cylinder 1 nozzle «A»

Open circuit

P020156

Cylinder 1 nozzle «A»

Invalid / incompatible configuration

P020211

Cylinder 2 injector «A»

Short to ground

P020212

Cylinder 2 injector «A»

Circuit Short to Battery Voltage

P020213

Cylinder 2 injector «A»

Open circuit

P020256

Cylinder 2 injector «A»

Invalid / incompatible configuration

P020311

Cylinder 3 injector «A»

Short to ground

P020312

Cylinder 3 injector «A»

Circuit Short to Battery Voltage

P020313

Cylinder 3 injector «A»

Open circuit

P020356

Cylinder 3 injector «A»

Invalid / incompatible configuration

P020411

Cylinder 4 nozzle «A»

Short to ground

P020412

Cylinder 4 nozzle «A»

Circuit Short to Battery Voltage

P020413

Cylinder 4 nozzle «A»

Open circuit

P020456

Cylinder 4 nozzle «A»

Invalid / incompatible configuration

P020511

Cylinder 5 injector «A»

Short to ground

P020512

Cylinder 5 injector «A»

Circuit Short to Battery Voltage

P020513

Cylinder 5 injector «A»

Open circuit

P020556

Cylinder 5 injector «A»

Invalid / incompatible configuration

P020611

Cylinder 6 nozzle «A»

Short to ground

P020612

Cylinder 6 nozzle «A»

Circuit Short to Battery Voltage

P020613

Cylinder 6 nozzle «A»

Open circuit

P020656

Cylinder 6 nozzle «A»

Invalid / incompatible configuration

P021700

Engine coolant temperature exceeded status

No subtype information

P021800

The condition of the transmission oil temperature rise

No subtype information

P021900

State of excess of engine speed

No subtype information

P023400

Overcharging state of turbocharger / supercharger

No subtype information

P024311

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Short to ground

P024312

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Circuit Short to Battery Voltage

P024313

Solenoid of the bypass damper «A» of the turbocharger / supercharger

Open circuit

P025612

Fuel Injector Diesel Injector

Circuit Short to Battery Voltage

P025614

Fuel Injector Diesel Injector

Short to ground or open

P025692

Fuel Injector Diesel Injector

Characteristics or malfunctioning

P026A00

The efficiency of the charge air cooler is below the threshold

No subtype information

P029800

Excess temperature of engine oil

No subtype information

P029900

Insufficient supercharging of the turbocharger / supercharger

No subtype information

P02CC00

Fuel injector cylinder 1 — determination of the correction at the minimum limit

No subtype information

P02CD00

Fuel injector cylinder 1 — determination of the correction at the maximum limit

No subtype information

P02CE00

Fuel injector cylinder 2 — determination of the correction at the minimum limit

No subtype information

P02CF00

Fuel injector cylinder 2 — determination of the correction at the maximum limit

No subtype information

P02D000

Fuel injector cylinder 3 — determination of the correction at the minimum limit

No subtype information

P02D100

Fuel injector cylinder 3 — determination of the correction at the maximum limit

No subtype information

P02D200

Fuel injector of the cylinder 4 — determination of the correction at the minimum limit

No subtype information

P02D300

Fuel injector cylinder 4 — determination of the correction at the maximum limit

No subtype information

P02D400

Fuel injector cylinder 5 — determination of the correction at the minimum limit

No subtype information

P02D500

Fuel injector cylinder 5 — determination of the correction at the maximum limit

No subtype information

P02D600

Fuel injector of the cylinder 6 — determination of the correction at the minimum limit

No subtype information

P02D700

Fuel injector of the cylinder 6 — determination of the correction at the maximum limit

No subtype information

P02E011

Airflow control at the diesel engine inlet

Short to ground

P02E012

Airflow control at the diesel engine inlet

Circuit Short to Battery Voltage

P02E013

Airflow control at the diesel engine inlet

Open circuit

P02E07C

Airflow control at the diesel engine inlet

Slow reaction

P02E09B

Airflow control at the diesel engine inlet

High / excessive flow

P02E09C

Airflow control at the diesel engine inlet

Low / insufficient flow

P02E601

Diesel Engine Admission Regulator Position Sensor

General electrical fault

P02E612

Diesel Engine Admission Regulator Position Sensor

Circuit Short to Battery Voltage

P02E613

Diesel Engine Admission Regulator Position Sensor

Open circuit

P02E697

Diesel Engine Admission Regulator Position Sensor

The operation of the component or system is difficult or blocked

P02E699

Diesel Engine Admission Regulator Position Sensor

Parameter limit exceeded

P03351F

Crankshaft Position Sensor «A»

Intermittent signal in the circuit

P033531

Crankshaft Position Sensor «A»

Missing signal

P033538

Crankshaft Position Sensor «A»

Incorrect signal frequency

P034031

Camshaft position sensor «A» — row 1 or separate sensor

Missing signal

P034038

Camshaft position sensor «A» — row 1 or separate sensor

Incorrect signal frequency

P04007C

Exhaust gas recirculation flow «A»

Slow reaction

P04009B

Exhaust gas recirculation flow «A»

High / excessive flow

P04009C

Exhaust gas recirculation flow «A»

Low / insufficient flow

P040311

Control of EGR «A»

Short to ground

P040312

Control of EGR «A»

Circuit Short to Battery Voltage

P040313

Control of EGR «A»

Open circuit

P040341

Control of EGR «A»

Total checksum error

P040371

Control of EGR «A»

Driven drive

P040392

Control of EGR «A»

Characteristics or malfunctioning

P040901

The differential pressure sensor EGR

General electrical fault

P040912

The differential pressure sensor EGR

Circuit Short to Battery Voltage

P040913

The differential pressure sensor EGR

Open circuit

P040964

The differential pressure sensor EGR

Violation of signal reliability

P040A01

Temperature sensor «A» of the exhaust gas recirculation system

General electrical fault

P040A11

Temperature sensor «A» of the exhaust gas recirculation system

Short to ground

P040A13

Temperature sensor «A» of the exhaust gas recirculation system

Open circuit

P040A64

Temperature sensor «A» of the exhaust gas recirculation system

Violation of signal reliability

P041A11

Temperature sensor circuit «B» of the exhaust gas recirculation system

Short to ground

P041A12

Temperature sensor circuit «B» of the exhaust gas recirculation system

Circuit Short to Battery Voltage

P041A2A

Temperature sensor circuit «B» of the exhaust gas recirculation system

Stuck signal in the range

P042000

The efficiency of the catalyst system is below the threshold

No subtype information

P047001

The gauge of pressure of exhaust gases «A»

General electrical fault

P047012

The gauge of pressure of exhaust gases «A»

Circuit Short to Battery Voltage

P047013

The gauge of pressure of exhaust gases «A»

Open circuit

P047064

The gauge of pressure of exhaust gases «A»

Violation of signal reliability

P047511

Exhaust Pressure Control Valve «A»

Short to ground

P047512

Exhaust Pressure Control Valve «A»

Circuit Short to Battery Voltage

P047513

Exhaust Pressure Control Valve «A»

Open circuit

P047572

Exhaust Pressure Control Valve «A»

The actuator jammed in the open position

P048011

Fan control circuit 1

Short to ground

P048012

Fan control circuit 1

Circuit Short to Battery Voltage

P048013

Fan control circuit 1

Open circuit

P048613

Sensor «B» of the EGR system

Open circuit

P049D99

Control position «A» EGR exceeded the threshold of training

Parameter limit exceeded

P04D900

Control of the closed loop EGR system at the limit — the flow is too small

No subtype information

P04DA00

Control of the closed loop EGR system at the limit — the flow is too strong

No subtype information

P050011

Vehicle speed by wheel

Short to ground

P050013

Vehicle speed by wheel

Open circuit

P051A01

Crankcase Pressure Sensor

General electrical fault

P051A12

Crankcase Pressure Sensor

Circuit Short to Battery Voltage

P051A13

Crankcase Pressure Sensor

Open circuit

P051A64

Crankcase Pressure Sensor

Violation of signal reliability

P052001

Engine oil pressure switch / relay «A»

General electrical fault

P052012

Engine oil pressure switch / relay «A»

Circuit Short to Battery Voltage

P052013

Engine oil pressure switch / relay «A»

Open circuit

P052064

Engine oil pressure switch / relay «A»

Violation of signal reliability

P052400

Engine oil pressure too low

Engine oil pressure too low

P052607

Fan Speed ​​Sensor Circuit

Mechanical faults

P052612

Fan Speed ​​Sensor Circuit

Circuit Short to Battery Voltage

P053E00

Crankcase pressure — too high

No subtype information

P054001

Control of the inlet air heater «A»

General electrical fault

P054011

Control of the inlet air heater «A»

Short to ground

P054013

Control of the inlet air heater «A»

Open circuit

P054070

Control of the inlet air heater «A»

Drive stuck when on

P05407F

Control of the inlet air heater «A»

Drive stuck when turned off

P054464

Exhaust temperature sensor — Row 1 Sensor 1

Violation of signal reliability

P055A01

Engine oil pressure switch / relay «B»

General electrical fault

P055A12

Engine oil pressure switch / relay «B»

Circuit Short to Battery Voltage

P055A13

Engine oil pressure switch / relay «B»

Open circuit

P055A64

Engine oil pressure switch / relay «B»

Violation of signal reliability

P055F00

Engine oil pressure out of range

No subtype information

P05E311

Parking brake sensor / switch circuit

Short to ground

P05E362

Parking brake sensor / switch circuit

Signal comparison error

P05E364

Parking brake sensor / switch circuit

Violation of signal reliability

P061511

Starter relay

Short to ground

P061512

Starter relay

Circuit Short to Battery Voltage

P061513

Starter relay

Open circuit

P06279C

Fuel pump control «A»

Low / insufficient flow

P064111

Sensor reference voltage «A»

Short to ground

P064112

Sensor reference voltage «A»

Circuit Short to Battery Voltage

P06411C

Sensor reference voltage «A»

Output from the voltage range in the circuit

P065111

Sensor reference voltage «V»

Short to ground

P066601

Internal temperature sensor for control module «A»

General electrical fault

P066611

Internal temperature sensor for control module «A»

Short to ground

P06B016

Sensor supply voltage «A»

Voltage in the circuit below the threshold

P06B017

Sensor supply voltage «A»

Voltage in the circuit above the threshold

P06B316

Sensor supply «B»

Voltage in the circuit below the threshold

P06B317

Sensor supply «B»

Voltage in the circuit above the threshold

P06DA71

Engine Oil Pressure Adjustment

Driven drive

P06E616

Sensor supply voltage «C»

Voltage in the circuit below the threshold

P06E617

Sensor supply voltage «C»

Voltage in the circuit above the threshold

P073021

Recommended transfer

The amplitude of the signal is less than the minimum

P073022

Recommended transfer

The amplitude of the signal above the maximum value

P07307C

Recommended transfer

Slow reaction

P100101

Engine stop switch

General electrical fault

P100111

Engine stop switch

Short to ground

P100112

Engine stop switch

Circuit Short to Battery Voltage

P100190

Engine stop switch

Clogged in the open position

P100192

Engine stop switch

Characteristics or malfunctioning

P100211

Pre-heater heater relay

Short to ground

P100212

Pre-heater heater relay

Circuit Short to Battery Voltage

P100213

Pre-heater heater relay

Open circuit

P100701

Air filter indicator

General electrical fault

P100711

Air filter indicator

Short to ground

P100712

Air filter indicator

Circuit Short to Battery Voltage

P100713

Air filter indicator

Open circuit

P101711

Valve for draining water from fuel

Short to ground

P101E11

The valve of full blocking of the channel of a transmission

Short to ground

P101E12

The valve of full blocking of the channel of a transmission

Circuit Short to Battery Voltage

P101E13

The valve of full blocking of the channel of a transmission

Open circuit

P102111

Volvo Compression Brake Control Circuit (VCB)

Short to ground

P102112

Volvo Compression Brake Control Circuit (VCB)

Circuit Short to Battery Voltage

P102113

Volvo Compression Brake Control Circuit (VCB)

Open circuit

P108600

The oil level is moderately low

No subtype information

P109300

Engine oil pressure is moderately low

No subtype information

P10C011

Volvo Compression Brake Control Circuit (VCB) «2»

Short to ground

P10C012

Volvo Compression Brake Control Circuit (VCB) «2»

Circuit Short to Battery Voltage

P10C013

Volvo Compression Brake Control Circuit (VCB) «2»

Open circuit

P10E100

Differential pressure in particulate filter is critical

No subtype information

P10E200

Differential pressure on particulate filter moderately high

No subtype information

P10F800

Air filter clogged

No subtype information

P10FE00

Clogging of particulate filter — soot accumulation moderately high — row 1

No subtype information

P110400

Factory setting

No subtype information

P110501

Back-up switch circuit «A» of the engine

General electrical fault

P110511

Back-up switch circuit «A» of the engine

Short to ground

P110512

Back-up switch circuit «A» of the engine

Circuit Short to Battery Voltage

P110573

Back-up switch circuit «A» of the engine

The actuator jammed in the closed position

P111600

Absolute pressure sensor in the reservoir is a moderate excess

No subtype information

P111800

Absolute pressure sensor in the collector — a strong excess

No subtype information

P111945

The intake manifold temperature is too high at a moderate level

Failure of program memory

P111A00

Intake manifold temperature too high

No subtype information

P111D00

The engine coolant level is moderately low

No subtype information

P111E00

Engine coolant temperature is moderately high

No subtype information

P112500

Engine oil temperature — moderately high

No subtype information

P112800

The oil pressure for cooling the pistons is moderately low

No subtype information

P112900

Transmission oil temperature moderately high

No subtype information

P112B00

The turbocharger / turbocharger drive temperature «A»

No subtype information

P112E00

Exhaust gas temperature moderately high — row 1

No subtype information

P113411

Air purge valve for fuel injection into the exhaust aftertreatment system

Short to ground

P113413

Air purge valve for fuel injection into the exhaust aftertreatment system

Open circuit

P113472

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the open position

P113473

Air purge valve for fuel injection into the exhaust aftertreatment system

The actuator jammed in the closed position

P113500

Crankcase pressure too high relative to atmospheric pressure

No subtype information

P113600

Error of calibration of the correlation of NOx 1/2 sensors — row 1

No subtype information

P113711

Oil thermostat

Short to ground

P113712

Oil thermostat

Circuit Short to Battery Voltage

P113713

Oil thermostat

Open circuit

P113F11

Idling switch confirmation cable with buffering — VECU side

Short to ground

P113F12

Idling switch confirmation cable with buffering — VECU side

Circuit Short to Battery Voltage

P114000

Volvo Compression Brake Control (VCB) — too low oil temperature

No subtype information

P114101

Idling switch confirmation cable with buffering — ECM side

General electrical fault

P114113

Idling switch confirmation cable with buffering — ECM side

Open circuit

P114123

Idling switch confirmation cable with buffering — ECM side

Constantly low signal level

P114124

Idling switch confirmation cable with buffering — ECM side

Constantly high signal level

P114411

High voltage side of the starter relay

Short to ground

P114412

High voltage side of the starter relay

Circuit Short to Battery Voltage

P114413

High voltage side of the starter relay

Open circuit

P114500

The level of the reducing agent is moderately low

No subtype information

P114700

Pressure in the fuel distribution pipe / system, row 1 — moderately too high

No subtype information

P114B00

The turbocharger / turbocharger drive temperature «A» is too low

No subtype information

P114E00

EGR drive temperature outside the operating range

No subtype information

P115000

Correlation of Sensor / Switch Voltage «A» / «D» Throttle Position / Pedal Position

No subtype information

P115100

Excess temperature of the post-treatment system

No subtype information

P115211

Starting fuel pump

Short to ground

P115212

Starting fuel pump

Circuit Short to Battery Voltage

P115213

Starting fuel pump

Open circuit

P115400

The connection between the bodywork control module «A» and the instrument cluster control module (IPC)

No subtype information

P117311

Low Transmission Range Authorization Valve

Short to ground

P117312

Low Transmission Range Authorization Valve

Circuit Short to Battery Voltage

P117313

Low Transmission Range Authorization Valve

Open circuit

P117401

Transmission range inquiry

General electrical fault

P117411

Transmission range inquiry

Short to ground

P117412

Transmission range inquiry

Circuit Short to Battery Voltage

P117600

Starter motor is deactivated — temperature rise

No subtype information

P117700

Starter motor is deactivated — gearbox is not in neutral position

No subtype information

P117800

The starter motor is deactivated — the gear of the electric motor of the starter motor is stuck

No subtype information

P117900

Starter motor is deactivated — power take-off is active

No subtype information

P117B01

Temperature sensor switch in engine compartment

General electrical fault

P117B11

Temperature sensor switch in engine compartment

Short to ground

P117B12

Temperature sensor switch in engine compartment

Circuit Short to Battery Voltage

P117C00

The requested range of gears is too high

No subtype information

P117D00

Requested driver transfer too low

No subtype information

P117E00

Driver’s request is too high

No subtype information

P117F11

Bypass valve of the hydraulic valve

Short to ground

P117F12

Bypass valve of the hydraulic valve

Circuit Short to Battery Voltage

P117F13

Bypass valve of the hydraulic valve

Open circuit

P203164

Exhaust temperature sensor — Row 1 Sensor 2

Violation of signal reliability

P203A86

Reagent level sensor «A»

Invalid signal

P203F00

Reducer level is low

No subtype information

P204F93

Characteristics of the SCR system — dosing failure

Does not work

P207F9A

Quality of the reducing agent

Working conditions of a component or system

P20D711

Controlling the fuel supply to the exhaust aftertreatment system

Short to ground

P20D713

Controlling the fuel supply to the exhaust aftertreatment system

Open circuit

P20D773

Controlling the fuel supply to the exhaust aftertreatment system

The actuator jammed in the closed position

P20DD01

Fuel pressure sensor for exhaust gas aftertreatment

General electrical fault

P20DD12

Fuel pressure sensor for exhaust gas aftertreatment

Circuit Short to Battery Voltage

P20DD13

Fuel pressure sensor for exhaust gas aftertreatment

Open circuit

P20EE00

The efficiency of the SCR NOx catalyst is below the threshold (row 1)

No subtype information

P20F400

AdBlue consumption is too low

No subtype information

P20F500

Reducer consumption too high

No subtype information

P210900

Performance characteristics of the «A» minimum limiter of the throttle / pedal position

No subtype information

P213600

Correlation of Sensor / Switch Voltage «A» / «C» Throttle Position / Pedal Position

No subtype information

P215A62

Correlation of vehicle speed with wheel speed

Signal comparison error

P215A64

Correlation of vehicle speed with wheel speed

Violation of signal reliability

P216300

Performance characteristics of the maximum limit sensor «A» of the throttle / pedal position

No subtype information

P220012

NOx sensor — series 1 sensor 1

Circuit Short to Battery Voltage

P220013

NOx sensor — series 1 sensor 1

Open circuit

P22001C

NOx sensor — series 1 sensor 1

Output from the voltage range in the circuit

P220064

NOx sensor — series 1 sensor 1

Violation of signal reliability

P220093

NOx sensor — series 1 sensor 1

Does not work

P222601

Barometric pressure circuit

General electrical fault

P222612

Barometric pressure circuit

Circuit Short to Battery Voltage

P222613

Barometric pressure circuit

Open circuit

P222664

Barometric pressure circuit

Violation of signal reliability

P225C00

Characteristics of the NOx sensor — high level signaling — row 1 sensor 1

No subtype information

P225D00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 1

No subtype information

P225E67

Characteristics of the NOx sensor — high level signaling — row 1 sensor 2

Wrong signal after event

P225F00

Characteristics of the NOx sensor — low level of the signal — row 1 sensor 2

No subtype information

P226401

Water sensor in fuel

General electrical fault

P226411

Water sensor in fuel

Short to ground

P226413

Water sensor in fuel

Open circuit

P228D72

The fuel pressure regulator 1 has exceeded the control limits — too high a pressure

The actuator jammed in the open position

P228E00

The fuel pressure regulator 1 has exceeded the training limits — too low a pressure

No subtype information

P228F00

The fuel pressure regulator 1 has exceeded the training limits — too high a pressure

No subtype information

P229E12

NOx sensor — row 1 sensor 2

Circuit Short to Battery Voltage

P229E13

NOx sensor — row 1 sensor 2

Open circuit

P229E1C

NOx sensor — row 1 sensor 2

Output from the voltage range in the circuit

P229E64

NOx sensor — row 1 sensor 2

Violation of signal reliability

P229E93

NOx sensor — row 1 sensor 2

Does not work

P22FB92

Sensor Specifications NOx — Sensor — Row 1 Sensor 1

Characteristics or malfunctioning

P22FE00

Sensor Specifications NOx — Sensor — Row 1 Sensor 2

No subtype information

P242800

Exhaust gas temperature too high

No subtype information

P242A64

Exhaust temperature sensor — Row 1 Sensor 3

Violation of signal reliability

P244A00

Differential pressure on the diesel particulate filter after-treatment 1 is too small (row 1)

No subtype information

P244B00

The differential pressure on the diesel particulate filter after-treatment 1 is too large (row 1)

No subtype information

P244C00

The exhaust gas temperature is too low to regenerate the particulate filter (row 1)

No subtype information

P245264

Particulate filter pressure sensor «A»

Violation of signal reliability

P245700

Coolant efficiency of the exhaust gas recirculation system is below the threshold value

No subtype information

P246300

Clogged particulate filter — soot accumulation — row 1

No subtype information

P249D00

Control of the injection of the reducing agent in a closed loop at the limit — the flow is too small

No subtype information

P249E00

Injection of the reducing agent in a closed loop at the limit — the flow is too high

No subtype information

P249F92

Excessive time for switching to the closed-loop diesel particulate filter regeneration control mode

Characteristics or malfunctioning

P24A000

Control of DPF regeneration in a closed loop at the limit — the temperature is too low

No subtype information

P24A100

Control of DPF regeneration in a closed loop at the limit — the temperature is too high

No subtype information

P24A200

The regeneration of the diesel particulate filter is not complete (row 1)

No subtype information

P24A400

Clogging of the diesel particulate filter — soot accumulation too large (row 1)

No subtype information

P250A11

Engine oil level sensor

Short to ground

P250A13

Engine oil level sensor

Open circuit

P250F00

Engine oil level too low

No subtype information

P253901

Low Fuel Pressure Sensor Circuit

General electrical fault

P253912

Low Fuel Pressure Sensor Circuit

Circuit Short to Battery Voltage

P253913

Low Fuel Pressure Sensor Circuit

Open circuit

P255601

Engine Coolant Level Sensor / Relay

General electrical fault

P255611

Engine Coolant Level Sensor / Relay

Short to ground

P255612

Engine Coolant Level Sensor / Relay

Circuit Short to Battery Voltage

P255613

Engine Coolant Level Sensor / Relay

Open circuit

P256000

Engine Coolant Level — Low

No subtype information

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P256214

Sensor «A» turbocharger supercharging control position

Short to ground or open

P259C00

Excessive time for entering the supercharging control of the turbocharger «A» in a closed loop

No subtype information

P25A911

Control oil supply for cooling pistons

Short to ground

P25A912

Control oil supply for cooling pistons

Circuit Short to Battery Voltage

P25A913

Control oil supply for cooling pistons

Open circuit

P25A971

Control oil supply for cooling pistons

Driven drive

P25AE00

The oil pressure for cooling the pistons is too low

No subtype information

P260011

Coolant Pump Control Circuit / Break

Short to ground

P260012

Coolant Pump Control Circuit / Break

Circuit Short to Battery Voltage

P260013

Coolant Pump Control Circuit / Break

Open circuit

P268111

Control of the bypass valve «A» of the engine coolant

Short to ground

P268112

Control of the bypass valve «A» of the engine coolant

Circuit Short to Battery Voltage

P268113

Control of the bypass valve «A» of the engine coolant

Open circuit

P269711

Injection Fuel Injector «A»

Short to ground

P269713

Injection Fuel Injector «A»

Open circuit

P269773

Injection Fuel Injector «A»

The actuator jammed in the closed position

P26977A

Injection Fuel Injector «A»

Fluid leakage or seal failure

P2A1612

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Circuit Short to Battery Voltage

P2A1614

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Short to ground or open

P2A1692

Control unit «D» fuel flow meter injection pump (cam / rotor / nozzle)

Characteristics or malfunctioning

P2A1E12

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Circuit Short to Battery Voltage

P2A1E14

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Short to ground or open

P2A1E92

Control unit «F» fuel flow meter injection pump (cam / rotor / injector)

Characteristics or malfunctioning

U000188

CAN Backbone bus 2 communication network

Bus Off

U001088

CAN Backbone bus 1 of the communication network

Bus Off

U008088

Communication Subnet of the car engine

Bus Off

U010100

Lost Communication With TECU

No subtype information

U010A00

Lost communication with the A module of the exhaust gas recirculation system

No subtype information

U010C00

The communication with the turbocharger / supercharger control module is broken

No subtype information

U012100

The communication with the anti-lock braking system (ABS)

No subtype information

U012900

Lost Communication With Brake Control Module

No subtype information

U014100

Lost connection with VMCU

No subtype information

U014200

Lost connection with the body control module «B»

No subtype information

U015500

Communication with the instrument cluster control module (IPC) is broken

No subtype information

U016700

Lost communication with the car immobilizer control module

No subtype information

U029D00

Communication with NOx sensor «A» is broken

No subtype information

U029E00

The communication with the NOx sensor «B» is broken

No subtype information

U032300

Software incompatibility with the dashboard control module

No subtype information

U033100

Incompatibility of software with the bodywork control module «A»

No subtype information

U042600

From the immobilizer control module of the car, unreliable data

No subtype information

U116600

Lost communication with CIOM

No subtype information

U116900

Lost connection with DACU

No subtype information

U116B00

Communication with TCM on the high-speed communication bus CAN

No subtype information

U116C00

Communication with TCM on the CAN bus of the power plant is broken

No subtype information

U116F00

Communication with the control module of the supply of the reducing agent via the engine subnetwork is broken

No subtype information

U117100

The communication with the control unit of the body equipment via the high-speed communication bus CAN

No subtype information

U117300

The communication with the IPC control unit via the high-speed communication CAN

No subtype information

U117888

CAN bus communication system bus

Bus Off

U1FFF68

Factory mode active

Event details

U300001

Electronic control module

General electrical fault

U300041

Electronic control module

Total checksum error

U300044

Electronic control module

Data memory failure

U300045

Electronic control module

Failure of program memory

U300049

Electronic control module

Internal failure of electronics

U300257

Vehicle Identification Number

Invalid / incompatible software component

————————————————————————————————————————————————————————————

U000188

CAN bus off

Bus off

CAN communication interrupted.

Communication bus is short circuited to ground or battery, or there are connector or harness

problems.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on Backbone 2.

CAN Communication Backbone 2 Net

————————————————————————————————————————————————————————————

U001088

CAN bus off

Bus off

CAN communication interrupted.

Communication bus is short circuited to ground or battery, or there are connector or harness

problems.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on Backbone 1.

CAN Communication Backbone 1 Net

————————————————————————————————————————————————————————————

U004688

CAN bus off

Bus off

CAN communication interrupted.

Communication bus is short circuited to ground or battery, or there are connector or harness

problems.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on Infotainment Net.

CAN Communication Infotainment Net

————————————————————————————————————————————————————————————

U200A88

CAN bus off

Bus off

CAN communication interrupted.

Communication bus is short circuited to ground or battery, or there are connector or harness

problems.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on Display Net.

CAN Communication Display Net

————————————————————————————————————————————————————————————

U300041

CRC checksum occured

General Checksum Failure

Reset of Electronic Control Unit, HMIIOM

Multiple possible root causes e.g. flash error, EMC

problem

Diagnostic Service 14. No additional action is needed.

1. Reprogram ECU.

2. Replace ECU.

Electronic control unit

————————————————————————————————————————————————————————————

U300044

RAM check failed

Data Memory Failure

Reset of Electronic Control

Unit, HMIIOM

ECU hardware error

Diagnostic Service 14. No additional

action is needed.

1. Reprogram ECU.

2. Replace ECU.

Electronic control unit

————————————————————————————————————————————————————————————

U300045

NVRAM/ROM check failed

Program Memory Failure

Reset of Electronic Control Unit, HMIIOM

ECU hardware error

Diagnostic Service 14. No additional action is needed.

1. Reprogram ECU.

2. Replace ECU.

Electronic control unit

————————————————————————————————————————————————————————————

U300046

EEPROM check failed

Calibration / Parameter Memory Failure

Reset of Electronic Control Unit, HMIIOM

ECU hardware error

Diagnostic Service 14. No additional action is needed.

1. Reprogram ECU.

2. Replace ECU.

Electronic control unit

————————————————————————————————————————————————————————————

U300049

ECU Internal failure

Internal Electronic

Failure

Reset of Electronic Control

Unit, HMIIOM

ECU hardware error

Diagnostic Service 14. No additional

action is needed.

1. Reprogram ECU.

2. Replace ECU.

Electronic control unit

————————————————————————————————————————————————————————————

U30004A

Slave Module on wrong LIN channel

Incorrect Component Installed

Reset of Electronic Control Unit, HMIIOM

Wrong LIN slave Module or not correct connected

Diagnostic Service 14. No additional action is needed.

Check that the correct LIN-slaves are connected and that they are connected on the correct channels.

Electronic control unit

————————————————————————————————————————————————————————————

U30004B

ECU temperature is above 85ºC

Over Temperature

Reset of Electronic Control Unit, HMIIOM

1. Environment temperature above normal operating range (-40 °C – 85

°C)

2. ECU damaged

Diagnostic Service 14. No additional action is needed.

1. Check ECU environment

2. Replace ECU if fault is still present when environment temperature is in nomral range

Electronic control unit

————————————————————————————————————————————————————————————

U300094

Unexpected operation detected

Unexpected Operation

Reset of Electronic Control Unit, HMIIOM

SW Application error ( Watch dog failure et.c)

Diagnostic Service 14. No additional action is needed.

1. Reprogram ECU.

2. Replace ECU.

Electronic control unit

————————————————————————————————————————————————————————————

U300316

Voltage < 8 V +- 10%

Circuit Voltage Below Threshold

None

1. Drained battery

2. Power supply system failure

Diagnostic Service 14. No additional action is needed.

Check battery status.

Battery Power

————————————————————————————————————————————————————————————

U300317

Voltage  > 32V +- 10%

Circuit Voltage Above Threshold

None

1. Drained battery

2. Power supply system failure

Diagnostic Service 14. No additional action is needed.

Check battery status.

Battery Power

————————————————————————————————————————————————————————————

U1FFF68

Truck is in Factory

Mode

Event Information

None

Truck is in Factory Mode

Diagnostic Service 14. No additional

action is needed.

Set P1C54 to FALSE

Factory Mode Active

————————————————————————————————————————————————————————————

U1FE049

LIN related HW fault detected.

Internal Electronic Failure

LIN communication interrupted.

ECU hardware error.

Diagnostic Service 14. No additional action is needed.

Replace ECU.

ECU LIN Hardware

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U114300

Signal from BBM missing

No Sub Type Information

BBM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and BBM. If this is the only lost communication DTC then fault is more probable to be close to the BBM.

This fault can also appear by incorrect calibration.

Lost Communication With BBM

————————————————————————————————————————————————————————————

U114400

Signal from RCIOM missing

No Sub Type Information

RCIOM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U014000, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and RCIOM. If this is the only lost communication DTC then fault is more probable to be close to the RCIOM.

This fault can also appear by incorrect calibration.

Lost Communication With RCIOM

————————————————————————————————————————————————————————————

U114500

Signal from CCIOM missing

No Sub Type Information

CCIOM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U014000, U300316 and 300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and CCIOM. If this is the only lost communication DTC then fault is more probable to be close to the CCIOM.

This fault can also appear by incorrect calibration.

Lost Communication With CCIOM

————————————————————————————————————————————————————————————

U114600

Signal from DACU missing

No Sub Type Information

DACU diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and DACU. If this is the only lost communication DTC then fault is more probable to be close to the DACU.

This fault can also appear by incorrect calibration.

Lost Communication With DACU

————————————————————————————————————————————————————————————

U010000

Signal from EMS missing

No Sub Type Information

EMS diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and EMS. If this is the only lost communication DTC then fault is more probable to be close to the EMS.

This fault can also appear by incorrect calibration.

Lost Communication with EMS

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U010100

Signal from TECU missing

No Sub Type Information

TECU diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and TECU. If this is the only lost communication DTC then fault is more probable to be close to the TECU.

This fault can also appear by incorrect calibration.

Lost Communication with TECU

————————————————————————————————————————————————————————————

U014000

Signal from VMCU missing

No Sub Type Information

VMCU diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and VMCU. If this is the only lost communication DTC then fault is more probable to be close to the VMCU.

This fault can also appear by incorrect calibration.

Lost Communication With VMCU

————————————————————————————————————————————————————————————

U114000

Signal from APM missing

No Sub Type Information

APM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U014000, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and APM. If this is the only lost communication DTC then fault is more probable to be close to the APM.

This fault can also appear by incorrect calibration.

Lost Communication With APM

————————————————————————————————————————————————————————————

U109F00

Signal from IC missing

No Sub Type Information

IC diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and IC. If this is the only lost communication DTC then fault is more probable to be close to the IC.

This fault can also appear by incorrect calibration.

Lost Communication With IC

————————————————————————————————————————————————————————————

U10A500

Signal from SID missing

No Sub Type Information

SIDH diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and SIDH. If this is the only lost communication DTC then fault is more probable to be close to the SIDH.

This fault can also appear by incorrect calibration.

Lost Communication With SID

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U10A700

Signal from FCIOM missing

No Sub Type Information

FCIOM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U014000, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and FCIOM. If this is the only lost communication DTC then fault is more probable to be close to the FCIOM.

This fault can also appear by incorrect calibration.

Lost Communication With FCIOM

————————————————————————————————————————————————————————————

U10AB00

Signal from CCM missing

No Sub Type Information

CCM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and CCM. If this is the only lost communication DTC then fault is more probable to be close to the CCM.

This fault can also appear by incorrect calibration.

Lost Communication With CCM

————————————————————————————————————————————————————————————

U10AC00

Signal from DDM missing

No Sub Type Information

DDM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and DDM. If this is the only lost communication DTC then fault is more probable to be close to the DDM.

This fault can also appear by incorrect calibration.

Lost Communication With DDM

————————————————————————————————————————————————————————————

U10AD00

Signal from FAS missing

No Sub Type Information

FAS diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U014000, U300316 and 300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and FAS. If this is the only lost communication DTC then fault is more probable to be close to the FAS.

This fault can also appear by incorrect calibration.

Lost Communication With FAS

————————————————————————————————————————————————————————————

U10AE00

Signal from Alarm missing

No Sub Type Information

Alarm diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and Alarm. If this is the only lost communication DTC then fault is more probable to be close to the Alarm.

This fault can also appear by incorrect calibration.

Lost Communication With Alarm

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U10AF00

Signal from PDM missing

No Sub Type Information

PDM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and PDM. If this is the only lost communication DTC then fault is more probable to be close to the PDM.

This fault can also appear by incorrect calibration.

Lost Communication With PDM

————————————————————————————————————————————————————————————

U10B000

Signal from SRS missing

No Sub Type Information

SRS diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and SRS. If this is the only lost communication DTC then fault is more probable to be close to the SRS.

This fault can also appear by incorrect calibration.

Lost Communication With SRS

————————————————————————————————————————————————————————————

U10B100

Signal from TPM missing

No Sub Type Information

TPM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and TPM. If this is the only lost communication DTC then fault is more probable to be close to the TPM.

This fault can also appear by incorrect calibration.

Lost Communication With TPM

————————————————————————————————————————————————————————————

U10B200

Signal from CIOM missing

No Sub Type Information

CIOM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and CIOM. If this is the only lost communication DTC then fault is more probable to be close to the CIOM.

This fault can also appear by incorrect calibration.

Lost Communication With CIOM

————————————————————————————————————————————————————————————

U10B400

Signal from LECM missing

No Sub Type Information

LECM diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LECM. If this is the only lost communication DTC then fault is more probable to be close to the LECM.

This fault can also appear by incorrect calibration.

Lost Communication With LECM

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U10B600

Signal from Audio missing

No Sub Type Information

Audio diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and Audio. If this is the only lost communication DTC then fault is more probable to be close to the Audio.

This fault can also appear by incorrect calibration.

Lost Communication With Audio

————————————————————————————————————————————————————————————

U10B800

Signal from VS missing

No Sub Type Information

VS diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and VS. If this is the only lost communication DTC then fault is more probable to be close to the VS.

This fault can also appear by incorrect calibration.

Lost Communication With VS

————————————————————————————————————————————————————————————

U114200

Signal from TGW2 missing

No Sub Type Information

TGW2 diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and TGW2. If this is the only lost communication DTC then fault is more probable to be close to the TGW2.

This fault can also appear by incorrect calibration.

Lost Communication With TGW2

————————————————————————————————————————————————————————————

U115900

Signal from EAS missing

No Sub Type Information

EAS diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and EAS. If this is the only lost communication DTC then fault is more probable to be close to the EAS.

This fault can also appear by incorrect calibration.

Lost Communication With EAS – Extra Axle Steering

————————————————————————————————————————————————————————————

U010E00

Signal from ACM missing

No Sub Type Information

Aftertreatment Control Module diagnostic warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and ACM. If this is the only lost communication DTC then fault is more probable to be close to the ACM.

This fault can also appear by incorrect calibration.

Lost Communication With Reductant Control Module

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U114E00

Signal from Tachograph missing

No Sub Type Information

Tachograph diagnostic warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and Tachograph. If this is the only lost communication DTC then fault is more probable to be close to the Tachograph.

This fault can also appear by incorrect calibration.

Lost Communication With Tachograph

————————————————————————————————————————————————————————————

U012900

Signal from Brake system control module missing

No Sub Type Information

Wire Brake System diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and Brake system. If this is the only lost communication DTC then fault is more probable to be close to the Brake system.

This fault can also appear by incorrect calibration.

Lost Communication With Brake System Control Module

————————————————————————————————————————————————————————————

U114F00

Signal from BLECU missing

No Sub Type Information

Bending Light diagnostic warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U014000, U10A700, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and BLECU. If this is the only lost communication DTC then fault is more probable to be close to the BLECU.

This fault can also appear by incorrect calibration.

Lost Communication With Bending Light ECU

————————————————————————————————————————————————————————————

U115000

Signal from FLS missing

No Sub Type Information

Forward Looking Sensor diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U114600, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and FLS. If this is the only lost communication DTC then fault is more probable to be close to the FLS.

This fault can also appear by incorrect calibration.

Lost Communication With Forward Looking Sensor

————————————————————————————————————————————————————————————

U115100

Signal from LPOS missing

No Sub Type Information

Lane Position diagnostic warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U114600, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LPOS. If this is the only lost communication DTC then fault is more probable to be close to the LPOS.

This fault can also appear by incorrect calibration.

Lost Communication With Lane Position Object Control Unit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U115200

Signal from WRC missing

No Sub Type Information

Wireless Remote Control diagnostic  warnings and functional messages affected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 911 and D-950.  It can be triggered at the same time as: U10B200, U300316 and U300317.

Connector or harness problems.

Problem with sending ECU.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and WRC. If this is the only lost communication DTC then fault is more probable to be close to the WRC.

This fault can also appear by incorrect calibration.

Lost Communication With Wireless Remote Control System

————————————————————————————————————————————————————————————

U115500

Max number of DTC:s within the

system reached.

No Sub Type Information

No more DTC can be set after this DTC is set.

Reception of 29 DTCs will trigger the setting of this

DTC.

Diagnostic Service 14. No additional action is needed.

Control other set DTCs. When they are erased this DTC should also be erased.

DTC Notification Max Limit Reached

————————————————————————————————————————————————————————————

U115600

TIPSI (The

Astonishing Tribe (TAT) Inter Process Software Interface

) hearbeat signalling is missing or other TIPSI related transport errors occur.

No Sub Type Information

Driver Information Display will stop working.

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Software error, software mismatch between HMIIOM and IC or communication problems.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between HMIIOM and IC. Also check that the software versions match.

Driver Information Display

————————————————————————————————————————————————————————————

U115694

TIPSI (The

Astonishing Tribe (TAT) Inter Process Software Interface

) memory allocation error occur.

Unexpected Operation

Driver Information Display resets

Software Error

Diagnostic Service 14. No additional action is needed.

Reprogram HMIIOM or IC.

Driver Information Display

————————————————————————————————————————————————————————————

U115700

TIPSI (The

Astonishing Tribe (TAT) Inter Process Software Interface) hearbeat signalling is missing or other TIPSI related transport errors occur.

No Sub Type Information

Secondary Information Display  will stop working.

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

Software error, software mismatch between HMIIOM and IC or communication problems.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between HMIIOM and IC. Also check that the software versions match.

Secondary Information Display

————————————————————————————————————————————————————————————

U115794

TIPSI (The

Astonishing Tribe (TAT) Inter Process Software Interface) memory allocation error occur.

Unexpected Operation

Secondary Information Display resets

Software Error

Diagnostic Service 14. No additional action is needed.

Reprogram HMIIOM or IC.

Secondary Information Display

————————————————————————————————————————————————————————————

U114D11

LIN transceiver has detected too many transmit or receive errors and pin is short circuited to ground.

Circuit Short To Ground

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 15.

LIN15 Communication Bus

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U114D12

LIN transceiver has detected too many transmit or receive errors and pin is short circuited to battery.

Circuit Short To Battery

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 15.

LIN15 Communication Bus

————————————————————————————————————————————————————————————

U114D88

LIN transceiver has detected too many transmit or receive errors.

Bus off

LIN communication interrupted.

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 854. It can be triggered at the same time as: U114D11 and U114D12.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 15.

LIN15 Communication Bus

————————————————————————————————————————————————————————————

U114786

Gear Lever LIN slave Module Invalid Signal

Signal Invalid

GearShift function will be effected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 798. It can be triggered at the same time as:

U114B11, U114B12 and

U114B88.

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and GLU/DashGSU.

2. Check GLU/DashGSU functionality. If faulty then replace GLU/DashGSU.

Gear Lever LIN Module

————————————————————————————————————————————————————————————

U114787

Gear Lever LIN Module slave not responding

Missing Message

GearShift function will be effected

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 798. It can be triggered at the same time as:

U114B11, U114B12 and

U114B88.

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and GLU/DashGSU.

2. Check GLU/DashGSU functionality. If faulty then replace GLU/DashGSU.

Gear Lever LIN Module

————————————————————————————————————————————————————————————

U114886

Stalk Module LIN slave Module Invalid

Signal

Signal Invalid

Functions controlled by the Stalk module will be

effected

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and SM.

2. Check SM functionality. If faulty then replace SM.

Stalk Module LIN Module

————————————————————————————————————————————————————————————

U114887

Stalk Module LIN slave Module not

responding

Missing Message

Functions controlled by the Stalk module will be

effected

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and SM.

2. Check SM functionality. If faulty then replace SM.

Stalk Module LIN Module

————————————————————————————————————————————————————————————

U114986

Steering Wheel Switch LIN slave Module Invalid

Signal

Signal Invalid

Functions controlled by the Steering Wheel Switch module will be effected

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and SWS.

2. Check SWS functionality. If faulty then replace SWS.

Steering Wheel Switch LIN Module

————————————————————————————————————————————————————————————

U114987

Steering Wheel Switch LIN slave Module not

responding

Missing Message

Functions controlled by the Steering Wheel Switch module will be effected.

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and SWS.

2. Check SWS functionality. If faulty then replace SWS.

Steering Wheel Switch LIN Module

————————————————————————————————————————————————————————————

U114A86

Secondary Information Display Control Panel LIN slave Module Invalid Signal

Signal Invalid

Functions related to Display Control Panel will be effected.

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and SIDCP.

2. Check SIDCP functionality. If faulty then replace SIDCP.

Secondary Information Display Control Panel LIN Module

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U114A87

Secondary Information Display Control Panel LIN slave Module not responding

Missing Message

Functions related to Display Control Panel will be effected

LIN Slave Module error

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors on between ECU and SIDCP.

2. Check SIDCP functionality. If faulty then replace SIDCP.

Secondary Information Display Control Panel LIN Module

————————————————————————————————————————————————————————————

U114B11

LIN transceiver has detected too many transmit or receive errors and pin is short circuited to ground.

Circuit Short To Ground

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 13.

LIN13 Communication Bus

————————————————————————————————————————————————————————————

U114B12

LIN transceiver has detected too many transmit or receive errors and pin is short circuited to battery.

Circuit Short To Battery

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 13.

LIN13 Communication Bus

————————————————————————————————————————————————————————————

U114B88

LIN transceiver has detected too many transmit or receive errors.

Bus off

LIN communication interrupted.

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 854. It can be triggered at the same time as: U114B11 and U114B12.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and LIN nodes on LIN 13.

2. Replace HMIIOM ECU.

LIN13 Communication Bus

————————————————————————————————————————————————————————————

U114C11

LIN transceiver has detected too many transmit or receive errors and pin is short circuited to ground.

Circuit Short To Ground

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 14.

LIN14 Communication Bus

————————————————————————————————————————————————————————————

U114C12

LIN transceiver has detected too many transmit or receive errors and pin is short circuited to battery.

Circuit Short To Battery

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 14.

LIN14 Communication Bus

————————————————————————————————————————————————————————————

U114C88

LIN transceiver has detected too many transmit or receive errors.

Bus off

LIN communication interrupted.

Note: This DTC can be set as a secondary DTC  which has been agreed in deviation D- 854. It can be triggered at the same time as: U114C11 and U114C12.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and LIN nodes on LIN 14.

LIN14 Communication Bus

————————————————————————————————————————————————————————————

B150216

Voltage < 8V

Circuit Voltage Below Threshold

Gear shifting functionality stops to work.

1. Connecter or harness problems.

2. GLU or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and GLU.

2. Check output voltage from ECU to GLU.

Gear Lever Unit

————————————————————————————————————————————————————————————

B150217

Voltage > 18V

Circuit Voltage Above Threshold

Gear shifting functionality stops to work.

1. Connecter or harness problems.

2. GLU or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and GLU.

2. Check output voltage from ECU to GLU.

Gear Lever Unit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

B150249

Sensor fault

detected.

Internal Electronic

Failure

Gear position will be set to

last reliable position.

Faulty sensors or lever stuck

Diagnostic Service 14. No additional

action is needed.

Replace GLU.

Gear Lever Unit

————————————————————————————————————————————————————————————

B150294

Both up and down shift button activation simultaneously

Unexpected Operation

Gear position will be set to last reliable position.

Unexpected Operation

Diagnostic Service 14. No additional action is needed.

Replace GLU.

Gear Lever Unit

————————————————————————————————————————————————————————————

B150716

Voltage < 7 V

Circuit Voltage Below Threshold

LIN is switched off. SIDCP will not work.

1. Connecter or harness problems.

2. SIDCP or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SIDCP.

2. Check output voltage from ECU to SIDCP.

Secondary Information Display Control Panel

————————————————————————————————————————————————————————————

B150717

Voltage > 20 V

Circuit Voltage Above Threshold

LIN is switched off. SIDCP will not work.

1. Connecter or harness problems.

2. SIDCP or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SIDCP.

2. Check output voltage from ECU to SIDCP.

Secondary Information Display Control Panel

————————————————————————————————————————————————————————————

B150744

RAM error, read compare  failure after write

operation.

Data Memory Failure

ECU resets continuously. DTC will never be set.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SIDCP

Secondary Information Display Control Panel

————————————————————————————————————————————————————————————

B150745

ROM error, 16 bit checksum incorrect

Program Memory Failure

ECU resets continuously. DTC will never be set.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SIDCP

Secondary Information Display Control Panel

————————————————————————————————————————————————————————————

B150746

EEPROM checksum error

Calibration / Parameter Memory Failure

ECU resets continuously. DTC will never be set.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SIDCP

Secondary Information Display Control Panel

————————————————————————————————————————————————————————————

B150794

Watchdog error read from reset register

Unexpected Operation

ECU resets continuously. DTC will never be set.

Watchdog failure

Diagnostic Service 14. No additional action is needed.

Replace SIDCP

Secondary Information Display Control Panel

————————————————————————————————————————————————————————————

B150311

Input Signals of Brake Program Button <=  2,44 V OR Rain Sensor Button

<= 0,88 V OR Scroll Wheel <= 0,88 V

Circuit Short To Ground

It will not be possible to activate on or more of the following functions: Brake Program, Rain Sensor and/or use wipers.

Brake program button, rain sensor button or scroll wheel short circuit to ground.

Diagnostic Service 14. No additional action is needed.

Manual Check of Brake Program Button, Rainsensor Button and Scroll Wheel. Replace Stalk with erroneous function.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150312

Input Signals of Brake Program Button >= 4,5 V OR Rain Sensor Button

>= 4,78 V OR Scroll Wheel >= 4,88 V

Circuit Short To Battery

It will not be possible to activate on or more of the following functions: Brake Program, Rain Sensor and/or use wipers.

Brake program button, rain sensor button or scroll wheel short circuit to battery.

Diagnostic Service 14. No additional action is needed.

Manual Check of Brake Program Button, Rainsensor Button and Scroll Wheel. Replace Stalk with erroneous function.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150313

Open circuit conditions detected on Rain Sensor button OR Scroll

Wheel.

Circuit Open

It will not be possible to activate on or more of the following functions: Rain Sensor and/or use wipers.

Rain sensor button or scroll wheel has an open circuit.

Diagnostic Service 14. No additional action is needed.

Manual Check of Rainsensor Button and Scroll Wheel. Replace Stalk with erroneous function.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150316

Voltage < 8V

Circuit Voltage Below Threshold

LIN communicastion Interface shut down.

1. Connecter or harness problems.

2. SM1 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SM1.

2. Check output voltage from ECU to SM1.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150317

Voltage > 18V

Circuit Voltage Above Threshold

LIN communicastion Interface shut down.

1. Connecter or harness problems.

2. SM1 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SM1.

2. Check output voltage from ECU to SM1.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B15031C

Voltage < 2.1 V

Circuit Voltage Out of Range

None

1. Connecter or harness problems.

2. SM1 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

No action required.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150344

RAM Failure

Data Memory Failure

LIN communication

Interface shut down.

Memory failure

Diagnostic Service 14. No additional

action is needed.

Replace base plate of SM1.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150345

ROM Failure

Program Memory

Failure

LIN communication

Interface shut down.

Memory failure

Diagnostic Service 14. No additional

action is needed.

Replace base plate of SM1.

Stalk Module Variant 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

B150346

EEPROM failure

Calibration / Parameter Memory Failure

LIN communication Interface shut down.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace base plate of SM1.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B15034A

Incorrect Component detected

Incorrect Component Installed

It will not be possible to activate on or more of the following functions: Direction Indicators, Main Beam, Washers and Wipers and/or Retarder.

Direction Indicator stalk, washer wiper stalk or auxiliary stalk incorrectly mounted or damaged.

Diagnostic Service 14. No additional action is needed.

Check correct mountig of each Stalk.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150364

Scroll Wheel Unplausible Signal

Signal Plausibility Failure

It will not be possible to activate the wipers

manually.

Scroll Wheel damaged.

Diagnostic Service 14. No additional action is needed.

Replace washer wiper stalk.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150394

Watchdog Reset

Unexpected Operation

None

Watchdog failure

Diagnostic Service 14. No additional

action is needed.

Replace base plate of SM1.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150395

Detected to low input voltage from direction indicator stalk, washer wiper stalk or auxiliary stalk.

Incorrect Assembly

It will not be possible to activate on or more of the following functions: Direction Indicators, Main Beam, Washers and Wipers and/or Retarder.

Direction Indicator stalk, washer wiper stalk or auxiliary stalk dismounted.

Diagnostic Service 14. No additional action is needed.

Check correct mountig of each Stalk. Replace uncorrect mounted or damaged  Stalk.

Stalk Module Variant 1

————————————————————————————————————————————————————————————

B150416

Voltage < 7 volts +- 8%

Circuit Voltage Below Threshold

None

1. Connecter or harness problems.

2. SM2 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SM2.

2. Check output voltage from ECU to SM2.

Stalk Module Variant 2

————————————————————————————————————————————————————————————

B150417

Voltage > 18 volts +- 8%

Circuit Voltage Above Threshold

None

1. Connecter or harness problems.

2. SM2 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SM2.

2. Check output voltage from ECU to SM2.

Stalk Module Variant 2

————————————————————————————————————————————————————————————

B150444

RAM Error. read compare  failure after write operation.

Data Memory Failure

RAM DATA is untrustable, may affect functionality related to SM2. What it affects depends on where in RAM error occured.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SM2.

Stalk Module Variant 2

————————————————————————————————————————————————————————————

B150446

EEPROM checksum error.

Calibration / Parameter Memory Failure

EEPROM DATA is

untrustable, may affect functionality related to SM2. What it affects depends on where in EEPROM error occured.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SM2.

Stalk Module Variant 2

————————————————————————————————————————————————————————————

B150494

Watchdog error read from reset register

Unexpected Operation

Functionality related to SM2 will not work.

Watchdog failure

Diagnostic Service 14. No additional action is needed.

Replace SM2.

Stalk Module Variant 2

————————————————————————————————————————————————————————————

B150516

Voltage < 7 volts

Circuit Voltage Below Threshold

LIN is switched off

1. Connecter or harness problems.

2. SWS1 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SWS1.

2. Check output voltage from ECU to SWS1.

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150517

Voltage > 20 volts

Circuit Voltage Above Threshold

LIN is switched off LEDs are switched off

1. Connecter or harness problems.

2. SWS1 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check wires and connectors between ECU and SWS1.

2. Check output voltage from ECU to SWS1.

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150544

RAM error, read compare  failure after write

operation.

Data Memory Failure

ECU resets continuously. DTC will never be set.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SWS1.

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150545

ROM error, 16 bit checksum incorrect.

Program Memory Failure

ECU resets continuously. DTC will never be set.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SWS1.

Steering Wheel Switch Variant 1

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

B150546

EEPROM checksum error.

Calibration / Parameter Memory Failure

ECU resets continuously. DTC will never be set.

Memory failure

Diagnostic Service 14. No additional action is needed.

Replace SWS1.

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150584

One or several SWS buttons or scroll wheels short circuit to ground.

Signal Below Allowable Range

Reduced functionality for the right steering wheel switch. Possible that switches are not useable.

Short to ground

Diagnostic Service 14. No additional action is needed.

1. Check connection to left SWS1

2. Replace SWS1 if fault is still present

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150585

One or several SWS buttons or scroll wheels short circuit to battery or open circuit.

Signal Above Allowable Range

Reduced functionality for the right steering wheel switch. Possible that switches are not useable.

Short to battery or open circuit

Diagnostic Service 14. No additional action is needed.

1. Check connection to left SWS1

2. Replace SWS1 if fault is still present

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150594

Watchdog error read from reset register

Unexpected Operation

ECU resets continuously. DTC will never be set.

Watchdog failure

Diagnostic Service 14. No additional action is needed.

Replace SWS1.

Steering Wheel Switch Variant 1

————————————————————————————————————————————————————————————

B150611

Voltage = 0V

Circuit Short To Ground

Cruise Control functionality will be effected

Connection between right SWS buttons and left SWS buttons short circuited to

ground.

Diagnostic Service 14. No additional action is needed.

1. Check connection between left hand side and right hand side of SWS2.

2. Replace SWS2.

Steering Wheel Switch Variant 2

————————————————————————————————————————————————————————————

B150616

Voltage < 7V +- 10%

Circuit Voltage Below Threshold

SWS buttons may not work.

1. Connecter or harness problems.

2. SWS2 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check output voltage from HMIIOM to SWS2.

2. Replace SWS2

Steering Wheel Switch Variant 2

————————————————————————————————————————————————————————————

B150617

Voltage > 19V +- 10%

Circuit Voltage Above Threshold

SWS buttons may not work.

1. Connecter or harness problems.

2. SWS2 or HMIIOM

damaged.

Diagnostic Service 14. No additional action is needed.

1. Check output voltage from HMIIOM to SWS2.

2. Replace SWS2

Steering Wheel Switch Variant 2

————————————————————————————————————————————————————————————

B150694

MCU watchdog reset

Unexpected Operation

SWS2 resets

Watchdog failure

Diagnostic Service 14. No additional action is needed.

Replace SWS2.

Steering Wheel Switch Variant 2

————————————————————————————————————————————————————————————

B15084A

Incorrect Gearbox Stalk detected

Incorrect Component Installed

Gearshifting functionality will be effected

Incorrect Gearbox Stalk installed or wrong

configuration

Diagnostic Service 14. No additional action is needed.

Control that the correct gearbox stalk is installed if the truck should have a gearbox stalk.

Gearbox Stalk

————————————————————————————————————————————————————————————

B15094A

Incorrect Radio Satelite Stalk

detected

Incorrect Component Installed

Audio functionality will be effected

Incorrect Radio Satelite Stalk installed or wrong

configuration

Diagnostic Service 14. No additional action is needed.

Control that the correct radio satellite stalk is installed if the truck should have a radio satellite stalk.

Radio Satelite Stalk

————————————————————————————————————————————————————————————

B150A4A

Incorrect Retarder Stalk detected

Incorrect Component Installed

Auxiliary brakes will be effected

Incorrect Retarder Stalk installed or wrong

configuration

Diagnostic Service 14. No additional action is needed.

Control that the correct retarder stalk is installed if the truck should have a retarder stalk.

Retarder Stalk

————————————————————————————————————————————————————————————

B150B4A

Incorrect cruise

control switch detected

Incorrect Component Installed

Cruise Control functionality will be effected

Incorrect cruise control

switch installed or wrong configuration

Diagnostic Service 14. No additional action is needed.

Control that the correct speed control switches are installed if the truck should have speed control switches.

Cruise Control Switches

————————————————————————————————————————————————————————————

B150C4A

Incorrect phone control switch detected

Incorrect Component Installed

Will not be possible to naviage in menus and phone functionality will be

effected

Incorrect phone control switch installed or wrong configuration

Diagnostic Service 14. No additional action is needed.

Control that the correct phone control switches are installed if the truck should have phone control switches.

Phone Control Switches

————————————————————————————————————————————————————————————

B150D11

Voltage = 0V

Circuit Short To Ground

LIN communication

interrupted.

-Main connector pin 8 short

circuit to ground.

Diagnostic Service 14. No additional

action is needed.

Check wires and connectors between ECU and other ECUs on LIN 13.

LIN13 Power Supply

Circuit

————————————————————————————————————————————————————————————

B150D17

VP_LINA > 14V (VP_LINA_MON <

2,54)

Circuit Voltage Above Threshold

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on LIN 13.

LIN13 Power Supply Circuit

————————————————————————————————————————————————————————————

B150E11

Voltage = 0V

Circuit Short To Ground

LIN communication

interrupted.

-Main connector pin 9 short

circuit to ground.

Diagnostic Service 14. No additional

action is needed.

Check wires and connectors between ECU and other ECUs on LIN 14.

LIN14 Power Supply

Circuit

————————————————————————————————————————————————————————————

B150E17

VP_LINB > 14V (VP_LINB_MON < 2,54)

Circuit Voltage Above Threshold

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on LIN 14.

LIN14 Power Supply Circuit

————————————————————————————————————————————————————————————

B150F11

Voltage = 0V

Circuit Short To Ground

LIN communication interrupted.

-Main connector pin 10 short circuit to ground.

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on LIN 15.

LIN15 Power Supply Circuit

————————————————————————————————————————————————————————————

B150F17

VP_LINC > 14V (VP_LINC_MON <

2,54)

Circuit Voltage Above Threshold

LIN communication interrupted.

Connector or harness problems

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and other ECUs on LIN 15.

LIN15 Power Supply Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

————————————————————————————————————————————————————————————

U115371

Detection that there is a button that is stuck. Button is stuck after 1-4095s, depending on which button is stuck.

Actuator Stuck

Functions will be effected

Button stuck or driver has held button pressed longer than the allowed time

Diagnostic Service 14. No additional action is needed.

Control that GLU, SM, SWS and SIDCP buttons are working as they should.

Softkey and Rocker Buttons

————————————————————————————————————————————————————————————

C100054

Input parameter is missing.

Missing Calibration

Will not be possible to calibrate load for front axle.

Wrong calibration.

Diagnostic Service 14. No additional action is needed.

Correct calibration parameters.

Leaf Calculation Failure

————————————————————————————————————————————————————————————

U200B93

No response from Real Time Clock

No Operation

Clock may show incorrect time. Alarm clock, parking heater and refrigerator timer will not work.

Internal HW fault

Diagnostic Service 14. No additional action is needed.

Replace HMIIOM.

Real Time Clock (RTC)

————————————————————————————————————————————————————————————

U115A00

Signal from EMS missing

No Sub Type Information

Engine Malfunction Indication telltale will be activated “On steady” at least during current drive cycle

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

“Connector or harness problems.

Data link EMC problems. Problem with sending ECU.”

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and EMS. This fault can also appear by incorrect calibration.

Lost Communication with EMS

————————————————————————————————————————————————————————————

U115B00

Signal from EMS missing

No Sub Type Information

Engine Malfunction Indication telltale will be activated “On steady” at least during current drive cycle

Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.

“Connector or harness problems.

Data link EMC problems. Problem with sending ECU.”

Diagnostic Service 14. No additional action is needed.

Check wires and connectors between ECU and EMS. This fault can also appear by incorrect calibration.

Lost Communication with EMS

Понравилась статья? Поделить с друзьями:
  • U0140 ошибка пежо 408
  • U014787 ошибка мерседес w204
  • U0155 ошибка опель астра j
  • U0140 ошибка пежо 308
  • U0140 ошибка гранта