Состояние sql s0011 код ошибки 170

Sorry if the title is unclear.

As of right now, I just have a spreadsheet of a bunch of customers and orders. For example, a line in the spreadsheet might look like:

A Customer with an ID of 1 with name Sally and address 291 North Street bought item id 2.

The actual spreadsheet looks something like this table:

Customer Id Customer Name Customer Address Item Id Name Cost Order Id Ordered Date
1 Sally 291 North Street 2 Long Sleeves $20 1 1/1/2022
1 Sally 291 North Street 1 Shirt $15 1 1/1/2022
2 George 892 Lakers Ave 3 Backpack $30 5 4/9/2022

My goal is to properly normalize this data so it’s not as redundant. I’ve already separated the data into 3 tables, Items, Orders, and OrderInfo.

Items follows a structure like so:

Item Id (PK) Name Cost
1 XL Shirt $15
2 Long sleeves shirt $20
3 Backpack $30

Orders:

Order ID (PK/FK?) Customer ID Ordered Date
1 1 1/1/2022
5 2 4/9/2022

OrderInfo:

Order ID (PK/FK?) Item ID (PK/FK?)
1 2
1 1
5 3

As you can see from the orders table, I tried to combine all redundant orders where say user Sally ordered a long sleeves shirt and a regular shirt in the same order. However, this leaves redundant data in the OrdersInfo table, where the OrderId is the same for multiple fields because the customer bought multiple items in one order.

Is this correct? I am trying to define relationships on the tables in LibreOffice Base, and I can define the correct one-to-many relationships for all of them except for OrderInfo and Orders.

Here’s a screenshot of the relations and the error when I try to link the OrderID field.

Relations

Error

Error code:

SQL Status: S0011
Error code: -170

Primary or unique constraint required on main table: "Orders" in statement [ALTER TABLE "Order_Info" ADD  FOREIGN KEY ("order_id") REFERENCES "Orders" ("order_id")]

Sorry if the title is unclear.

As of right now, I just have a spreadsheet of a bunch of customers and orders. For example, a line in the spreadsheet might look like:

A Customer with an ID of 1 with name Sally and address 291 North Street bought item id 2.

The actual spreadsheet looks something like this table:

Customer Id Customer Name Customer Address Item Id Name Cost Order Id Ordered Date
1 Sally 291 North Street 2 Long Sleeves $20 1 1/1/2022
1 Sally 291 North Street 1 Shirt $15 1 1/1/2022
2 George 892 Lakers Ave 3 Backpack $30 5 4/9/2022

My goal is to properly normalize this data so it’s not as redundant. I’ve already separated the data into 3 tables, Items, Orders, and OrderInfo.

Items follows a structure like so:

Item Id (PK) Name Cost
1 XL Shirt $15
2 Long sleeves shirt $20
3 Backpack $30

Orders:

Order ID (PK/FK?) Customer ID Ordered Date
1 1 1/1/2022
5 2 4/9/2022

OrderInfo:

Order ID (PK/FK?) Item ID (PK/FK?)
1 2
1 1
5 3

As you can see from the orders table, I tried to combine all redundant orders where say user Sally ordered a long sleeves shirt and a regular shirt in the same order. However, this leaves redundant data in the OrdersInfo table, where the OrderId is the same for multiple fields because the customer bought multiple items in one order.

Is this correct? I am trying to define relationships on the tables in LibreOffice Base, and I can define the correct one-to-many relationships for all of them except for OrderInfo and Orders.

Here’s a screenshot of the relations and the error when I try to link the OrderID field.

Relations

Error

Error code:

SQL Status: S0011
Error code: -170

Primary or unique constraint required on main table: "Orders" in statement [ALTER TABLE "Order_Info" ADD  FOREIGN KEY ("order_id") REFERENCES "Orders" ("order_id")]

Sorry if the title is unclear.

As of right now, I just have a spreadsheet of a bunch of customers and orders. For example, a line in the spreadsheet might look like:

A Customer with an ID of 1 with name Sally and address 291 North Street bought item id 2.

The actual spreadsheet looks something like this table:

Customer Id Customer Name Customer Address Item Id Name Cost Order Id Ordered Date
1 Sally 291 North Street 2 Long Sleeves $20 1 1/1/2022
1 Sally 291 North Street 1 Shirt $15 1 1/1/2022
2 George 892 Lakers Ave 3 Backpack $30 5 4/9/2022

My goal is to properly normalize this data so it’s not as redundant. I’ve already separated the data into 3 tables, Items, Orders, and OrderInfo.

Items follows a structure like so:

Item Id (PK) Name Cost
1 XL Shirt $15
2 Long sleeves shirt $20
3 Backpack $30

Orders:

Order ID (PK/FK?) Customer ID Ordered Date
1 1 1/1/2022
5 2 4/9/2022

OrderInfo:

Order ID (PK/FK?) Item ID (PK/FK?)
1 2
1 1
5 3

As you can see from the orders table, I tried to combine all redundant orders where say user Sally ordered a long sleeves shirt and a regular shirt in the same order. However, this leaves redundant data in the OrdersInfo table, where the OrderId is the same for multiple fields because the customer bought multiple items in one order.

Is this correct? I am trying to define relationships on the tables in LibreOffice Base, and I can define the correct one-to-many relationships for all of them except for OrderInfo and Orders.

Here’s a screenshot of the relations and the error when I try to link the OrderID field.

Relations

Error

Error code:

SQL Status: S0011
Error code: -170

Primary or unique constraint required on main table: "Orders" in statement [ALTER TABLE "Order_Info" ADD  FOREIGN KEY ("order_id") REFERENCES "Orders" ("order_id")]

Я получаю эту ошибку при попытке подключиться к SQL Server.

ошибка Microsoft SQL Server: 18456

может кто-нибудь сказать мне, что код ошибки означает?

19 ответов:

проверьте эту статью в блоге от команды платформы данных.

https://blogs. msdn. com/b/sql_protocols/archive/2006/02/21/536201.aspx

вам действительно нужно посмотреть на состояние части сообщения об ошибке, чтобы найти основную причину проблемы.

после этого, Google, как исправить эту проблему.

перед открытием щелкните правой кнопкой мыши и выберите «Запуск от имени администратора». Это решило проблему для меня.

Я столкнулся с этой проблемой.

пожалуйста, посмотрите на прикрепленные изображения,

пожалуйста, измените свою проверку подлинности sql как SQL server и режим WindowsAuthenication,

и перезапустите Sql server.

enter image description here

двойной щелчок TCP / IP дал мне это:

TCP/IP properties, showing wrong IP address

IP-адрес был другого виртуального сервера! Это, наконец, заставило меня понять, что я просто запутался между серверами, и все хорошо работало на втором сервере.

щелкните правой кнопкой мыши пользователя, перейдите к свойствам, измените базу данных по умолчанию на master Это экран печати изображения, которое показывает, что вы должны проверить, если у вас есть ошибка 19456. Иногда это значение по умолчанию для базы данных, которую пользователь не имеет разрешения

пожалуйста, проверьте, если вы подключены к сети, если это член домена ПК. Кроме того, убедитесь, что вы не находитесь на двух домашних ПК, поскольку ваши маршруты могут быть неверными из-за сетевых показателей. У меня была эта проблема, когда я не мог подключиться к домену проверка подлинности SQL windows переключилась на локальную учетную запись ПК, но зарегистрировала ее как проверку подлинности SQL. Как только я отключил свой беспроводной адаптер и перезагрузился, интеграция Windows переключилась обратно на учетную запись домена и прошла проверку подлинности. Я уже настроил смешанный режим, как вы уже сделали, так что предыдущие сообщения не применяются.

для меня это было неправильно логин и пароль.

сначала перейдите в панель запуска, а затем выполните поиск локальных служб Затем нажмите на кнопку » Просмотр локальных служб» Затем он откроет окно службы, затем перейдите к SQL Server (MSSQLSERVER) щелкните правой кнопкой мыши на нем и нажмите кнопку стоп, а затем снова щелкните правой кнопкой мыши на нем и нажмите кнопку Пуск. Теперь вы можете войти в систему и ввести имя пользователя ‘СА’ и пароль свой пароль.

Я считаю, что это может произойти, если вы пытаетесь войти в систему с пользователем, который определен в Active Directory, но попробуйте использовать «аутентификацию SQL Server» на экране входа в систему. Я не знаю, как указать другого пользователя с проверкой подлинности NTLM/Windows: когда я нажимаю раскрывающийся список проверки подлинности Windows, имя пользователя и пароль отключаются, и я могу войти только как сам.

в случае, если вы не можете подключиться к аутентификации SQL, и вы пробовали другие решения.

Вы можете попробовать следующее:

проверьте подключение

проверяем состояние

Состояние 5

состояние войти

«вы не смотрите в нужном месте «или»то, что вы видите, это не то, что вы думаете».

локальный конфликт БД и SQLEXPRESS

Если вы подключаетесь к SSMS с проверкой подлинности Windows, и ваш экземпляр называется SQLEXPRESS, вы, вероятно, смотрите на LocalDb и не правильный сервер. Таким образом, вы только что создали свой логин на LocalDb.

при подключении через проверку подлинности SQL Server с SSMS, он будет пытаться подключиться к реальному серверу SQLEXPRESS, где ваш любимый логин еще не существует.

дополнительная информация: Проверьте вкладку параметры подключения, если вы не забыли какую-то странную строку подключения там.

Я столкнулся с той же проблемой. Сначала необходимо включить проверку подлинности в смешанном режиме. Более подробный Как включить проверку подлинности в смешанном режиме

Источники:

https://codengineering. ru/q/login-to-microsoft-sql-server-error-18456-23881

mariammm

1 / 1 / 0

Регистрация: 24.09.2019

Сообщений: 173

1

Ошибка при попытке создать таблицу

15.10.2020, 17:50. Показов 4194. Ответов 2

Метки нет (Все метки)


Пишу код и нажимаю на кнопку для создания, в первый раз всё ок, в следующие разы появляется ошибка

ERROR: ОШИБКА: отношение «cabins» уже существует

SQL state: 42P07

Oracle 11 SQL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
CREATE TABLE cabins
(
    Id SERIAL PRIMARY KEY,
    Num_of_passangers NUMERIC,
    Price NUMERIC(6)
);
 
CREATE TABLE passenger
(
    Id SERIAL PRIMARY KEY,
    Cabin_id INTEGER REFERENCES cabins (Id),
    Passport_data CHARACTER VARYING(30)
);
 
CREATE TABLE car
(
    Id SERIAL PRIMARY KEY,
    Passenger_id INTEGER REFERENCES passenger (Id),
    Brand CHARACTER VARYING(30),
    Payment CHARACTER VARYING(30),
    Num_of_car NUMERIC(30),
    Scan CHARACTER VARYING(30)
);
 
CREATE TABLE nationality
(
    Id SERIAL PRIMARY KEY,
    Country CHARACTER VARYING(30)
);
 
CREATE TABLE carriage
(
    Id SERIAL PRIMARY KEY,
    Num_of_carriage NUMERIC(30)
);

Миниатюры

Ошибка при попытке создать таблицу
 

__________________
Помощь в написании контрольных, курсовых и дипломных работ, диссертаций здесь

0

1184 / 914 / 367

Регистрация: 02.09.2012

Сообщений: 2,785

15.10.2020, 23:22

2

Так и что тут удивительного.
Объект создан был в первую попытку.
Во вторую попытку его уже создать нельзя. Сначала необходимо удалить.

1

remarkes

309 / 232 / 15

Регистрация: 01.07.2011

Сообщений: 812

Записей в блоге: 1

17.10.2020, 18:40

3

SQL
1
DROP TABLE cabins;

Потом заново создаёте таблицу вашими командами.
Чтобы ошибка не выскакивала, в CREATE TABLE можно добавить:

SQL
1
CREATE TABLE IF NOT EXISTS таблица(столбец тип_данных);

1

Содержание статьи:

    • SQL-сервер не найден или недоступен, ошибки соединения с SQL-сервером
      • Ошибка SQL-сервера 26
      • Ошибка SQL-сервера 18456
      • Не удалось запустить SQL-server — код ошибки 3417
    • Повреждена база данных
      • Код ошибки SQL-сервера 945
      • Код ошибки SQL-сервера 5172
      • Ошибка SQL-сервера 823
      • Ошибка SQL-сервера 8946
    • Другие ошибки SQL Server
      • Код ошибки SQL-сервера 1814
      • Код ошибки SQL-сервера 1067
      • SQL-сервер запускается, но работает слишком медленно
  • Если SQL-сервер не найден, убедитесь, что ваш экземпляр SQL-сервера действительно установлен и запущен. Для этого зайдите на компьютер, где он установлен, запустите диспетчер конфигурации SQL и проверьте, есть ли там тот экземпляр, к которому вы пытаетесь подключиться и запущен ли он. Нелишним будет также получить отчет об обнаружении компонентов SQL-серверов.
  • Если вы проделали п1. и не обнаружили источник проблемы, возможно, неверно указан IP-адрес компьютера или номер порта TCP. Перепроверьте их настройки.
  • Причиной того, что невозможно подключиться к SQL-серверу, также может быть сеть, убедитесь, что компьютер с SQL-сервером доступен по сети.
  • Проверьте, может ли клиентское приложение, установленное на том же компьютере, что и сервер, подключиться к SQL-серверу. Запустите SQL Server Management Studio(SSMS), в диалоговом окне “Подключиться к серверу” выберите тип сервера Database Engine, укажите способ аутентификации “Аутентификация Windows”, введите имя компьютера и экземпляра SQL-сервера. Проверьте подключение.

Обратите внимание, что многие сообщения об ошибках могут быть не показаны или не содержат достаточной информации для устранения проблемы. Это сделано из соображений безопасности, чтобы при попытке взлома злоумышленники не могли получить информацию об SQL-сервере. Полные сведения содержатся в логе ошибок, который обычно хранится по адресу C:Program FilesMicrosoft SQL ServerMSSQL13.MSSQLSERVERMSSQLLogERRORLOG, или там, куда его поместил администратор системы.

Ошибка SQL-сервера 26

Одна из наиболее часто встречающихся ошибок подключения к SQL-серверу, обычно связана с тем, что в настройках SQL-сервера не разрешены или ограничены удаленные соединения. Чтобы это исправить, попробуйте:

  • в SSMS в настройках SQL-сервера включите аутентификацию Windows
  • для брандмауэра Windows  создайте новое правило, которое разрешает подключение для всех программ и протоколов с указанного IP-адреса
  • убедитесь, что запущена служба SQL Server Browser

Ошибка SQL-сервера 18456

Эта ошибка означает, что попытка подключиться к серверу не успешна из-за проблем с именем пользователя или паролем. По коду ошибки в журнале ошибок можно узнать более точную причину, чтобы устранить ее.

Не удалось запустить SQL-server — код ошибки 3417

Возникает в случае, если были изменены настройки Windows или перемещена папка с файлами MSSQL.

  • зайдите в C:Program FilesMicrosoft SQLServerMSSQL.1MSSqLData — БезопасностьНастройки доступа — Учетная запись сетевой службы — добавьте учетную запись сетевой службы
  • проверьте, что MDF-файл не сжимается. Если это не так, отключите “Сжимать содержимое для экономии места на диске” в свойствах файла

Иногда ни один из этих способов не помогает, это значит, что файлы БД повреждены и ее придется восстанавливать из резервной копии.

Повреждена база данных

Код ошибки SQL-сервера 945

Ошибка 945 возникает, когда БД SQL-сервера помечена как IsShutdown. Проверьте, достаточно ли места на диске, достаточно ли прав у учетной записи для операций с БД, файлы MDF и LDF не должны быть помечены “Только для чтения”.

Код ошибки SQL-сервера 5172

SQL-сервер хранит свою физическую БД в первичном файле, в котором информация разбита постранично. Первая страница содержит информацию о заголовке mdf-файла и называется страницей заголовка. Она состоит из разнообразной информации о БД, такой как размер файла, подпись и т.д. В процессе прикрепления MDF на SQL-сервере часто возникает ошибка 5172. Это в основном происходит, если MDF-файл поврежден, информация в его заголовке тоже и соответственно сложно добраться до данных. Причиной может быть вирус, аварийное выключение системы, ошибка оборудования.

Ошибка SQL-сервера 823

SQL использует API Windows для операций ввода-вывода, но кроме завершения этих операций SQL проверяет все ошибки обращений к API. Если эти обращения несовместимы с ОС, появляется ошибка 823. Сообщение об ошибке 823 означает, что существует проблема с базовым оборудованием для хранения данных или с драйвером, который находится на пути запроса ввода-вывода. Пользователи могут столкнуться с этой ошибкой, если в файловой системе есть противоречия или поврежден файл базы данных.

Ошибка SQL-сервера 8946

Основной причиной ошибки 8946 так же, как и для 5172, является повреждение заголовков страниц БД SQL вследствие сбоя питания, вирусной атаки, отказа оборудования — SQL-сервер больше не может прочесть эти страницы.

Перечисленные ошибки 945, 5172, 823, 8946 можно устранить двумя методами:

  • если у вас есть свежая резервная копия базы — восстановить базу из этой копии
  • можно попробовать использовать специализированное ПО, такое как SQL Recovery Tool, чтобы восстановить поврежденные файлы

Желательно определить, что именно привело к возникновению ошибок и принять меры, чтобы это не повторялось — заменить плохо работающее оборудование, повысить информационную безопасность.

Код ошибки SQL-сервера 1814

SQL-сервер не может создать базу данных tempdb.  Убедитесь, что на выделенном под нее диске достаточно места и что у учетной записи хватает прав для записи в указанную директорию.

Код ошибки SQL-сервера 1067

Эта ошибка может возникать по разным причинам. Наиболее часто оказывается, что повреждены или отсутствуют конфигурационные файлы, SQL-сервер обращается к поврежденным системным файлам, ошибочные данные пользователя, нет информации про лицензию. В самых тяжелых случаях придется переустанавливать SQL-сервер. Но иногда помогает восстановление поврежденных файлов или изменение настроек SQL-сервера — вы можете создать новую учетную запись в домене и использовать ее для службы MSSQL.

SQL-сервер запускается, но работает слишком медленно

Проанализируйте журнал сервера, индексы (фрагментацию), запросы, задания, возможность взаимных блокировок.  Причин может быть масса.

Мы работаем с разными версиями SQL-сервера уже много лет, знакомы со всевозможными инструкциями SQL-сервера, видели самые разные варианты его настройки и использования на проектах у своих клиентов. В целом мы можем выделить четыре основных источника неполадок:

  • Индексы — причина проблем номер один. Неправильные индексы, отсутствующие индексы, слишком много индексов и подобное. Чаще всего при проблеме с индексами пользователи или администраторы базы данных не получают сообщения об ошибке, они просто видят, что база работает очень медленно и докопаться до причин бывает очень нелегко
  • изначально плохая архитектура сервера баз данных — ошибка, которую очень сложно и дорого исправлять на этапе, когда база уже используется
  • плохой код, в котором возможны блокировки и тупиковые места
  • использование конфигурации по умолчанию,

Если у вас не получается устранить ошибки сервера SQL-server самостоятельно, если они появляются снова и снова, то скорее всего в основе лежит одна из этих причин. В таком случае — если у вас произошла ошибка с SQL сервером, ваше ПО не видит SQL-сервер, либо нужно развернуть кластер SQL-серверов — вы всегда можете обратиться за консультацией и технической поддержкой к специалистам Интегруса, отправив заявку с сайта, написав на e-mail, либо позвонив в колл-центр нашей компании.

Присоединяйтесь к нам,

чтобы получать чек-листы, реальные кейсы, а также
обзоры сервисов раз в 2 недели.

Общие советы :

1) все данные (и виды платежей) — в одной плоской таблице (без каких-либо объединений ячеек) на одном(!) листе. Разделы «по счету», «по счетчику(по факту)» и «контроль» — это просто дополнительные столбцы справа.

2) вверху оставьте 10 строк для формул «итого», они всегда видны, т.к. область с формулами» закреплена»  

3) Долг и переплата — это всегда одна строка,  переплату можно ставить красным (формат ячейки — Отрицательное красным)

4) Из-за перерасчетов задним числом и смены тарифов — «помесячные итоги» не так полезны для анализа, как «нарастающий с начала года» или вообще «с начала времен». Я бы внес все квитки с начала года, добавил к январскому сумму долга/переплаты.  

5) Т.к. квитанция состоит всегда из 5 строк (Эл.Д, Эл.Н, ХВС, Вывоз ТКО, Утилизация ТКО) — то сразу их скопировать на 2 года вперед. Т.к. тариф меняется условного говоря «раз в полгода» и долго действует — сослаться формулами апреля — на март итд. И когда тариф эл. энергии станет не 2,83 а 4 — просто в том месяце перебиваем формулу на значение 4.

6) Нужно освоить функцию =СУММЕСЛИ(). Формула, которая суммирует все Дн. киловатты (по счету, счетчику и разницу) с начала года будет выглядеть так: =СУММЕСЛИ(Вид;’ЭлДень’;ПоСчету)
=СУММЕСЛИ(Вид;’ЭлДень’;ПоСчетчику)
=СУММЕСЛИ(Вид;’ЭлДень’;Отклон)
Чтобы можно было так легко писать и понимать формулы — нужно дать имена столбцам (точнее их диапазонам с 11-й по, скажем, по 71-строку, вперед на 5 лет). Для этой цели часто делают «официальную» шапку таблицы и ниже, через 1 пустую строку — дублируют её же краткой одной строкой «полей», в ней все слова без пробелов «Электроэнергия День кВт.ч» -> «ЭлДень». Понятности это не уменьшит, а вот скорость написания формулы вырастет пятикратно. Имена диапазонов можно тогда не создавать — Calc сам поймет где находится столбец «ЭлДень», с какой ячейки начинается и где заканчивается.

7) Самым левым столбцом делают «Период», вводят дату, скажем 31.01.18, 28.02.18. а в формате ячейки — Январь 18, Февраль 18 итд. После включения автофильтра на строке «полей», отделенной от «шапки» пустой строкой — появятся значки Автофильтра и возможность легко отбирать нужный период или нужный вид платежа в Автофильтре.

Чтобы автосуммировать видимое (прошедшее фильтр) — нужно освоить функцию =ПРОМЕЖУТОЧНЫЕ.ИТОГИ(9;СЧЕТ)

Полученная плоская таблица обладает громадным плюсом, она все-в-одном, логически целостна. Если захочется сделать по ней отчет — изучаем Сводные таблицы и диаграммы и делаем их на 2-м листе. Но даже просто =ПРОМЕЖУТОЧНЫЕ.ИТОГИ() даст вам информацию о среднем, максимальном, минимальном значении чего угодно за любой период, который выбирается Автофильтром.

Я плачу раз в полгода (ненавижу этот процесс и очереди, т.к. УК до сих пор работает только через ГРЦ-кассы, безнал никак, руководы УК по доброй российской традиции в федеральном розыске), — то оплату я ввожу одной строкой «между» квитанций (заплатил 10/03 — 45 тыс. руб.) Формула у меняя сама делит сумму одного платежа (45 тыс. руб.) на 108 отдельных чисел (по видам платежей). Это достигается суммированием накопленного долга с остатками долга и пени, пропорциональным делением. УК делает все точно так же, и когда с ними спорю — нахожу понимание. Разбивать 45 тр. на 6 квитанций х 6 видов платежей х 3 вида (недоимка/пеня/перерасчет) = 108 цифр — считаю пустой тратой времени. Учетные программы в УК и ТСЖ делают точно так же.


Description


perie_gut


2017-09-28 13:48:37 UTC

Created attachment 136586 [details]
sample

On the 5.3.6.1, it is possible to create a relationship between a primary column and an ordinary column, however, in the 5.4.1, it requires that the both column must be set to primary.


Comment 1


Alex Thurgood


2017-09-28 14:28:23 UTC

@perle_gut : please explain in detailed steps what it is your are attempting to do and provide a sample ODB file with instructions that we could try to follow to reproduce.

What kind of DB (embedded hsqldb, firebird, or external db) ?
How are you setting up the relationship (GUI, DDL/SQL, or backend instructions to db engine) ?

Setting to NEEDINFO.


Comment 2


perie_gut


2017-09-29 09:03:42 UTC

Created attachment 136610 [details]
sample of the db

Here is a sample of the HSQLDB. I was able to create the existing relationship using the stable release... If you are to recreate the entire db on a fresh release, then you will encounter the said error.


Comment 3


Robert Großkopf


2017-09-30 07:34:08 UTC

Have tested this one with OpenSUSE 42.2 64bit rpm Linux and 
LO Version: 5.4.2.1
Build-ID: dfa67a98bede79c671438308dc9036d50465d2cb
CPU-Threads: 4; Betriebssystem:Linux 4.4; UI-Render: Standard; VCL: kde4; 
Gebietsschema: de-DE (de_DE.UTF-8); Calc: group

Deleted the relationship between "PropertyType"."PropertyType" and "PropertyDetails"."PropertyType". 
Then saved and closed Base and LO. 
Reopened and set relationship.
When drawing from "PropertyDetails"."PropertyType" to "PropertyType"."PropertyType" the fields were connected well. You could save and reopen and the relationship is there.
Drawing the other way there doesn't appear 'n' and '1'. You are asked for the properties. If you only confirm this nothing happens. After saving and reopening the relationship has been gone.

Same buggy behavior with LO 5.3.6.1, also with all other versions down to 3.6.7.2. Haven't installed any version before, but it seems to be a very old bug. If you change the properties in the dialog for relationship to any action when deleting or updating something the relationship will be created well in every version of LO. Seems to be a bug in the dialog.

Could be this isn't the bug the reporter has detected - but this one I could confirm.


Comment 5


Julien Nabet


2017-10-22 19:30:58 UTC

I added traces to compare the 2 ways of adding relationship:
1) From non primary->primary (which works)
ORelationTableView::AddConnection
ORelationTableConnectionData::SetCardinality begin
checkPrimaryKey m_vConnLineData.size()=0
checkPrimaryKey m_vConnLineData.size()=0
ORelationTableConnectionData::Update
checkPrimaryKey m_vConnLineData.size()=1
checkPrimaryKey m_vConnLineData.size()=1
ORelationTableConnectionData::SetCardinality begin
checkPrimaryKey m_vConnLineData.size()=1
checkPrimaryKey m_vConnLineData.size()=1
checkPrimaryKey m_vConnLineData.size()=1
ORelationTableConnectionData::SetCardinality Cardinality::ManyOne
ORelationTableView::AddConnection call addConnection


2) From primary->non primary (which doesn't work)
with:
@@ -61,8 +61,7 @@ ORelationTableConnectionData::ORelationTableConnectionData( const TTableWindowDa
 {
     m_aConnName = rConnName;
 
-    if ( !m_aConnName.isEmpty() )
-        SetCardinality();
+    SetCardinality();
 }

ORelationTableView::AddConnection
ORelationTableConnectionData::SetCardinality debut
checkPrimaryKey m_vConnLineData.size()=0
checkPrimaryKey m_vConnLineData.size()=0

So in this last case:
no call to Update -> m_vConnLineData has a size of 0 -> checkPrimaryKey returns always false -> SetCardinality lets m_nCardinality to Cardinality::Undefined


Comment 6


perie_gut


2017-12-11 10:48:04 UTC

Version: 5.4.4.1 (x64)
Build ID: da790616461e15a10c95a80eb8ef8ee7b726c114
CPU threads: 4; OS: Windows 6.19; UI render: default; 
Locale: en-US (en_US); Calc: CL



As of the latest version, I still was not able to saved the relationship for the following:

ContractDetails.BargainPurchaseOptionType  = BargainPurchaseOption.BargainPurchaseOption

*also for the BargainRenewalOption

and I have tried to manually create the relationship (from insert > relationship) and got the following error

SQL Status: S0011
Error code: -170

Primary or unique constraint required on main table: "BargainRenewalOption" in statement [ALTER TABLE "ContractDetails" ADD  FOREIGN KEY ("BargainRenewalOption") REFERENCES "BargainRenewalOption" ("BargainRenewalOption")]


Comment 7


Julien Nabet


2017-12-11 12:51:40 UTC

perie: why did you set this to FIXED ?


Comment 8


Robert Großkopf


2017-12-11 15:41:43 UTC

(In reply to perie_gut from comment #6)
> As of the latest version, I still was not able to saved the relationship for
> the following:
> 
> ContractDetails.BargainPurchaseOptionType  =
> BargainPurchaseOption.BargainPurchaseOption
> 
> *also for the BargainRenewalOption
> 
> and I have tried to manually create the relationship (from insert >
> relationship) and got the following error
> 
> SQL Status: S0011
> Error code: -170
> 
> Primary or unique constraint required on main table: "BargainRenewalOption"
> in statement [ALTER TABLE "ContractDetails" ADD  FOREIGN KEY
> ("BargainRenewalOption") REFERENCES "BargainRenewalOption"
> ("BargainRenewalOption")]

Error appears, because "BargainRenewalOption" isn't unique. There are two primary-keys in the table. So how should the database be able to know which of the different rows of "BargainRenewalOption" will be the right?


Comment 9


perie_gut


2017-12-12 02:27:39 UTC

Julien, because of the stupid comment that I have posted earlier. Nevertheless, the issues identified before seams okay already when I tried with 5.4.3 version. I'll just set the ticket open.


Comment 10


Julien Nabet


2018-01-11 19:22:32 UTC

Let's revert to the previous state before the FIXED put by mistake.


Comment 12


Robert Großkopf


2018-04-16 15:38:33 UTC

(In reply to perie_gut from comment #11)
> Created attachment 141394 [details]
> trying to create a relationship to a table with 2 primary keys
> 
> Still cannot create a relationship to a table with 2 primary keys

Seems you are trying to create relationships between tables, which contain both more than one primary-key. I have tried this through direct SQL:

1: Primary or unique constraint required on main table: "journal_lines" in statement [ALTER TABLE "accountcode" ADD FOREIGN KEY ("accountcode") REFERENCES "journal_lines" ("accountcode")]

2: Primary or unique constraint required on main table: "accountcode" in statement [ALTER TABLE "journal_lines" ADD FOREIGN KEY ("accountcode") REFERENCES "accountcode" ("accountcode")]

You need a unique-field if you want to create a relationship. Three of of the tables doesn't have a unique-field. The have more than one primary key. HSQLDB doesn't support this.

The only bug here is: The GUI doesn't recognize this relation isn't be allowed. It paints a connection which doesn't show 1:1 or 1:n but this connection couldn't be saved.

Which tables did you try to connect with which relation?


Comment 13


QA Administrators


2019-10-07 03:03:23 UTC


Comment hidden (obsolete)

Dear perie_gut,

To make sure we're focusing on the bugs that affect our users today, LibreOffice QA is asking bug reporters and confirmers to retest open, confirmed bugs which have not been touched for over a year.

There have been thousands of bug fixes and commits since anyone checked on this bug report. During that time, it's possible that the bug has been fixed, or the details of the problem have changed. We'd really appreciate your help in getting confirmation that the bug is still present.

If you have time, please do the following:

Test to see if the bug is still present with the latest version of LibreOffice from https://www.libreoffice.org/download/

If the bug is present, please leave a comment that includes the information from Help - About LibreOffice.
 
If the bug is NOT present, please set the bug's Status field to RESOLVED-WORKSFORME and leave a comment that includes the information from Help - About LibreOffice.

Please DO NOT

Update the version field
Reply via email (please reply directly on the bug tracker)
Set the bug's Status field to RESOLVED - FIXED (this status has a particular meaning that is not 
appropriate in this case)


If you want to do more to help you can test to see if your issue is a REGRESSION. To do so:
1. Download and install oldest version of LibreOffice (usually 3.3 unless your bug pertains to a feature added after 3.3) from http://downloadarchive.documentfoundation.org/libreoffice/old/

2. Test your bug
3. Leave a comment with your results.
4a. If the bug was present with 3.3 - set version to 'inherited from OOo';
4b. If the bug was not present in 3.3 - add 'regression' to keyword


Feel free to come ask questions or to say hello in our QA chat: https://kiwiirc.com/nextclient/irc.freenode.net/#libreoffice-qa

Thank you for helping us make LibreOffice even better for everyone!

Warm Regards,
QA Team

MassPing-UntouchedBug


Comment 14


QA Administrators


2021-10-07 03:53:21 UTC

Dear perie_gut,

To make sure we're focusing on the bugs that affect our users today, LibreOffice QA is asking bug reporters and confirmers to retest open, confirmed bugs which have not been touched for over a year.

There have been thousands of bug fixes and commits since anyone checked on this bug report. During that time, it's possible that the bug has been fixed, or the details of the problem have changed. We'd really appreciate your help in getting confirmation that the bug is still present.

If you have time, please do the following:

Test to see if the bug is still present with the latest version of LibreOffice from https://www.libreoffice.org/download/

If the bug is present, please leave a comment that includes the information from Help - About LibreOffice.
 
If the bug is NOT present, please set the bug's Status field to RESOLVED-WORKSFORME and leave a comment that includes the information from Help - About LibreOffice.

Please DO NOT

Update the version field
Reply via email (please reply directly on the bug tracker)
Set the bug's Status field to RESOLVED - FIXED (this status has a particular meaning that is not 
appropriate in this case)


If you want to do more to help you can test to see if your issue is a REGRESSION. To do so:
1. Download and install oldest version of LibreOffice (usually 3.3 unless your bug pertains to a feature added after 3.3) from https://downloadarchive.documentfoundation.org/libreoffice/old/

2. Test your bug
3. Leave a comment with your results.
4a. If the bug was present with 3.3 - set version to 'inherited from OOo';
4b. If the bug was not present in 3.3 - add 'regression' to keyword


Feel free to come ask questions or to say hello in our QA chat: https://kiwiirc.com/nextclient/irc.freenode.net/#libreoffice-qa

Thank you for helping us make LibreOffice even better for everyone!

Warm Regards,
QA Team

MassPing-UntouchedBug

Я получаю эту ошибку при попытке подключиться к SQL Server.

ошибка Microsoft SQL Server: 18456

может кто-нибудь сказать мне, что код ошибки означает?

19 ответов:

проверьте эту статью в блоге от команды платформы данных.

https://blogs. msdn. com/b/sql_protocols/archive/2006/02/21/536201.aspx

вам действительно нужно посмотреть на состояние части сообщения об ошибке, чтобы найти основную причину проблемы.

после этого, Google, как исправить эту проблему.

перед открытием щелкните правой кнопкой мыши и выберите «Запуск от имени администратора». Это решило проблему для меня.

Я столкнулся с этой проблемой.

пожалуйста, посмотрите на прикрепленные изображения,

пожалуйста, измените свою проверку подлинности sql как SQL server и режим WindowsAuthenication,

и перезапустите Sql server.

enter image description here

двойной щелчок TCP / IP дал мне это:

TCP/IP properties, showing wrong IP address

IP-адрес был другого виртуального сервера! Это, наконец, заставило меня понять, что я просто запутался между серверами, и все хорошо работало на втором сервере.

щелкните правой кнопкой мыши пользователя, перейдите к свойствам, измените базу данных по умолчанию на master Это экран печати изображения, которое показывает, что вы должны проверить, если у вас есть ошибка 19456. Иногда это значение по умолчанию для базы данных, которую пользователь не имеет разрешения

пожалуйста, проверьте, если вы подключены к сети, если это член домена ПК. Кроме того, убедитесь, что вы не находитесь на двух домашних ПК, поскольку ваши маршруты могут быть неверными из-за сетевых показателей. У меня была эта проблема, когда я не мог подключиться к домену проверка подлинности SQL windows переключилась на локальную учетную запись ПК, но зарегистрировала ее как проверку подлинности SQL. Как только я отключил свой беспроводной адаптер и перезагрузился, интеграция Windows переключилась обратно на учетную запись домена и прошла проверку подлинности. Я уже настроил смешанный режим, как вы уже сделали, так что предыдущие сообщения не применяются.

для меня это было неправильно логин и пароль.

сначала перейдите в панель запуска, а затем выполните поиск локальных служб Затем нажмите на кнопку » Просмотр локальных служб» Затем он откроет окно службы, затем перейдите к SQL Server (MSSQLSERVER) щелкните правой кнопкой мыши на нем и нажмите кнопку стоп, а затем снова щелкните правой кнопкой мыши на нем и нажмите кнопку Пуск. Теперь вы можете войти в систему и ввести имя пользователя ‘СА’ и пароль свой пароль.

Я считаю, что это может произойти, если вы пытаетесь войти в систему с пользователем, который определен в Active Directory, но попробуйте использовать «аутентификацию SQL Server» на экране входа в систему. Я не знаю, как указать другого пользователя с проверкой подлинности NTLM/Windows: когда я нажимаю раскрывающийся список проверки подлинности Windows, имя пользователя и пароль отключаются, и я могу войти только как сам.

устранение неполадок подключения к SQL Server

в случае, если вы не можете подключиться к аутентификации SQL, и вы пробовали другие решения.

Вы можете попробовать следующее:

проверьте подключение

проверяем состояние

Состояние 5

состояние войти

«вы не смотрите в нужном месте «или»то, что вы видите, это не то, что вы думаете».

локальный конфликт БД и SQLEXPRESS

Если вы подключаетесь к SSMS с проверкой подлинности Windows, и ваш экземпляр называется SQLEXPRESS, вы, вероятно, смотрите на LocalDb и не правильный сервер. Таким образом, вы только что создали свой логин на LocalDb.

при подключении через проверку подлинности SQL Server с SSMS, он будет пытаться подключиться к реальному серверу SQLEXPRESS, где ваш любимый логин еще не существует.

дополнительная информация: Проверьте вкладку параметры подключения, если вы не забыли какую-то странную строку подключения там.

Я столкнулся с той же проблемой. Сначала необходимо включить проверку подлинности в смешанном режиме. Более подробный Как включить проверку подлинности в смешанном режиме

XMEye – распространенные коды ошибок (11307, 100000, 604000)

XMEye – программа для мониторинга камер наблюдения для Android и IOS устройств. XMEye получила обновление 6.0.7 в июне 2019, однако пользователи продолжают массово сталкиваться с ошибками 11307, 100000, 604000, 10005, 605005 и прочими. Сегодня попробуем детальнее разобраться с наиболее распространенными из них, а ниже дадим рекомендации как попытаться устранить проблемы самостоятельно.

Перед дальнейшим чтением рекомендуем убедиться что вы обновились до последней версии в Play Маркет. С каждым обновлением разработчики устраняют баги и ошибки в работе утилиты.

Ниже пройдемся по самым распространенным кодам ошибок на данный момент.

Не удалось подключиться код ошибки 11307 (Systemlnfo)

Ошибка 11307 и 10005 пожалуй самые распространенный. Причина сбоев связана с отсутствием Интернета, большим пингом или отсутствием вашего ID в сети. При задержке в скорости ваше устройство получает более низкий приоритет подключения и не соединяется совсем или часто просто висит в списке ожидания, отдавая приоритет устройствам с более высокой скоростью передачи данных.
Давайте более детально по каждому пункту:

Ошибки 10000 и 10005

Код 100000 вызван конфликтом IP адресов на роутере или маршрутизаторе с айпишником видео регистратора. Возможно вы сменили маршрутизатор или неправильно настроили IP адреса. В корректной конфигурации устройства должны находиться и работать в одной подсети.
Например на видеорегистраторе стоит IP 192.167.1.*, а на маршрутизаторе 192.167.2.*. Решением будет перенастроить IP на одном из устройств.
Код 10005 появляется при задержке подключения к сети.

 XMEye Error code:-10005

XMEye Error code:-10005

Наиболее часто сбой случается при работе от мобильных сетей с 3G или 4G подключением, поскольку скорость интернет-соединения у мобильных операторов скачет, а временами совсем пропадает.

Если не работает один из регистраторов, скорее всего неправильный айпи адрес на нем.

Ошибки с кодом 604000 и 605000

Данные ошибки появляются при отключении китайский серверов. Тут причин несколько: обновление серверов или программного обеспечения, обновление железа. При таких работах подключение к облаку либо обрывается, либо отключается. В любом случае проблема не на вашей стороне, тут остается подождать пока разработчики XMEye не завершат свои работы.
Коды 99987, 99993 можно отнести в эту же категорию. Такие сбои означают временную потерю связи в сегментах сети во время передачи данных между облачным сервером и NVR.

Куда отправлять заявки на техподдержку

Поскольку XMEye буквально засыпали сообщениями о сбоях они не придумали способа лучше, чем убрать раздел обратной связи с официального сайта. Однако они исправно принимают и отвечают на запросы по электронной почте. Официальный адрес технической поддержки xmeye@xiongmaitech. com.
Для начала составьте письмо с подробным описанием проблемы с обязательным указанием IP адреса камеры и серийного номера видео регистратора. Имейл пишется на английском языке, для этих целей можно воспользоваться Гул переводчиком: translate. google. com.
В итоге получим текст примерно следующего содержания:
Hello. I have a problem connecting the device. On the device, Error Code 10005
IP device address: 192.187.1.123
IP camera address: 192.187.1.124

Пример письма в техподдержку

Пример письма в техподдержку

Выводы

Ошибки XMEye можно условно разделить на несколько типов: проблемы с Интернет соединением, большой пинг или неверная конфигурация IP адресов, что приводят к отвязке ID устройства от облака. В этих случаях необходимо обратиться в техподдержку или подключить высокоскоростной тариф.
Если проблемы на китайских серверах, остается ждать когда сами разработчики устранят сбой или проведут техническое обслуживание.
Напишите в комментариях помогли ли вам советы из статьи, если вы не нашли ответа на свой вопрос, так же сообщите нам.

Евгений Загорский

Евгений Загорский

IT специалист. Автор информационных статей на тему Андроид смартфонов и IOS смартфонов. Эксперт в области решения проблем с компьютерами и программами: установка, настройка, обзоры, советы по безопасности ваших устройств. В свободное время занимается дизайном и разработкой сайтов.

Источники:

https://codengineering. ru/q/login-to-microsoft-sql-server-error-18456-23881

https://itpen. ru/xmeye-rasprostranennye-kody-oshibok-11307-100000-604000/

Сегодня впервые столкнулся с проблемой, что мой SQL сервер с 1С перестал отвечать. Как выяснилось, была остановлена служба SQL сервера и при ее запуске вылетала ошибка с кодом 17051. Ниже я расскажу о причинах возникновения этой ошибки и как мне удалось ее побороть.

Если заглянуть в просмотр событий на сервере, то мы увидим, что у службы SQL истек срок оценки, иными словами – закончилась лицензия.

Правильный метод устранения

Для решение этой проблемы, нужно обновить лицензию. Переходим в меню “Пуск” в “Центр установки SQL Server”, далее выбираем “Обслуживание”, затем “Обновление выпуска”, после чего нам необходимо будет ввести ключ на SQL Server и произвести обновление.

Костыльный метод

Меняем на сервере дату на ту, когда примерно вы устанавливали ваш SQL. Если сервер у вас в домене, то поменять дату через панель управления не получится.

Открываем консоль и пишем: date 01.01.2023 (указав нужную дату).

Далее запускаете службу SQL и снова меняете дату на текущую.

Состояние sql s0011 код ошибки 170

Загорание чек-лампочки и выдача ошибки с кодом Р0011 обозначает наличие нарушений в положении распределительного вала. При возникновении такой неполадки владелец транспортного средства должен немедленно обратиться за помощью в сервисный центр. Ошибка положения распредвала сигнализирует о неполадках в системе изменения фаз распределения газа. Появляются они, если распределительный вал совершает работу со значительным опережением. Рассмотрим детальнее этот вопрос и попробуем выяснить все тонкости данной кодовой ошибки.

Датчик выдает ошибку Р0011: о чем она оповещает?

Техническое описание и расшифровка ошибки P0011

Этот диагностический код неисправности (DTC) является общим кодом силового агрегата. Ошибка P0011 считается общим кодом, поскольку применяется ко всем маркам и моделям транспортных средств. Хотя конкретные этапы ремонта могут несколько отличаться в зависимости от модели.

Код P0011 относится к компонентам VVT (изменяемые газораспределения) или VCT (изменяемые газораспределения распределительного вала). А также ЭБУ автомобиля (модуль управления силовым агрегатом) или ECM (модуль управления двигателем).

VVT – это технология, используемая в двигателе, позволяющая получить большую мощность или КПД в различных рабочих точках.

Механизм состоит из нескольких различных компонентов, но код P0011 DTC конкретно относится к газораспределительным механизмам распределительного вала (кулачков). В этом случае, если ГРМ кулачков выше заданного предела (слишком высокий). То ошибка двигателя появится на панели, а код ее будет записан в память.

Распределительный вал «А» – это либо впускной левый, либо передний распределительный вал, если двигатель V-образный. Этот код относится только к банку 1. Банк 1 – это сторона двигателя, в которой находится первый цилиндр.

Признаки неисправности при возникновении ошибки P0011


Код ошибки на экране сканера

Практически во всех случаях и не только перечисленных выше автомобилях, код Р0011 говорит о нарушении положения распредвала или об рассинхронизации обоих распредвалов. Причин может быть несколько, но основные симптомы, характерные для этой поломки, выглядят так:


Схема фазовращателя
Симптомы не слишком явные и определить их довольно сложно, поэтому часто ошибка P0011 выскакивает уже тогда, когда двигатель отработал с неисправностью какое-то время. Кроме того, электронный блок управления сможет внести ошибку в память и показать её на бортовом компьютере или сканере в том случае, когда двигатель проработал в аварийном режиме не менее 15-20 минут. В этом и сложность диагностирования.

Интересное по теме: Работа над ошибками: U1900 на Форд Фокус 2

Причины возникновения ошибки

При существенной разнице между заданным углом смещения вала и фактическим смещением, которое считывает датчик. Клапан прекращает работу и модуль ECM активирует код P0011.

Код P0011 может означать, что произошла одна или несколько следующих проблем:

Поскольку электромагнитный клапан для регулировки фазировки распределительного вала использует поток масла для управления фазировкой. Загрязненное масло может привести к блокировке клапана в открытом или закрытом положении. Перед заменой клапана замените моторное масло и фильтр, а также сбросьте код двигателя.

Первичные признаки наличия ошибки P0011

Применительно к большинству моделей автомобилей ошибка Р0011 означает «ошибка положения распределительного вала». В некоторых источниках данную ошибку уточняют спецификацией «в сторону опережения». Многие автолюбители и начинающие автоэлектрики-диагносты ошибочно принимают эту ошибку за «ошибку синхронизации распредвала и коленвала». В данном случае согласно такому предположению должны быть соответствующие признаки:

Но при ошибке Р0011 таких признаков, выраженных в явном виде, обычно не наблюдается. Иногда Р0011 вообще может себя не проявлять. На некоторых моделях двигателей, например, Опелей, ошибка Р0011 проявляет себя следующим образом:

Эти факты можно объяснить повышенным потреблением топлива. При сильном опережении положения распредвала возможна блокировка запуска двигателя.

Как устранить или сбросить код неисправности P0011

Этот код DTC является результатом механического отказа блока VCT или связанных компонентов. Поэтому нет особой необходимости в дальнейшей электрической диагностике ошибки P0011. Для проведения испытаний компонентов блока VCT требуется смотреть специальное руководство по ремонту транспортного средства.

Также можно обратиться в сервис, дилерские технологии имеют расширенные инструменты и возможность выполнения подробных шагов по устранению неполадок. Включая возможность тестирования компонентов с помощью средства сканирования.

Диагностика и решение проблем

Проведите электрический тест фазового датчика. Убедитесь, что на контактах нет окисления, и что по проводам проходит питание.

Визуальный контроль фазового датчика. Датчик необходимо снять и проверить на наличие сколов, трещин и загрязнений. Которые в большинстве случаев образуются из-за нерегулярной замены масла в двигателе.

Проверьте клапан VVT газораспределительной системы. Установите мультиметр в режиме омметра. Измерьте сопротивление, чтобы убедиться, что обмотка не повреждена. Сопротивление должно быть в диапазоне 6,5-7,5 Ом, то обмотка не повреждена. Точные значения можно найти в техническом руководстве для конкретной модели автомобиля.

Измерьте, чтобы на клапан приходило напряжение 12 вольт при снятом датчике. Это будет гарантией, что шток будет двигаться.

Диагностика также возможна при рабочем двигателя. Нужно снять фишку и подать питание на два контакта от аккумулятора. Если клапан работает, частота вращения двигателя упадет, и он заглохнет.

Поведение автомобиля: как понять, что есть нарушение?

Сложность определения данной ошибки заключается в том, что ее достаточно трудно распознать водителю. Она не оказывает практически никакого влияния на режим автомобиля и совершенно не проявляется в движении. Объяснимо это тем, что работа распредвала с опережением не отражается на характеристиках мотора. Наличие такой неполадки не разрешит двигателю работать в оптимальном режиме, в связи с чем, значительно увеличится топливный расход и резко возрастет содержание вредных веществ в выбросных газах. Для некоторых двигателей ошибка сопровождается неустойчивой работой при высоких оборотах. Происходит это в основном из-за переизбытка топлива.

На каких автомобилях чаще встречается данная проблема

Проблема с кодом P0011 может встречаться на различных машинах, но всегда есть статистика, на каких марках эта ошибка присутствует чаше. Вот список некоторых из них:

С кодом неисправности Р0011 иногда можно встретить и другие ошибки. Наиболее часто встречаются следующие: P000A, P0010, P0012, P0014, P0016, P0020, P0021, P0022, P0121, P0300, P0449, P0455, P1516, P2101, P2143.

Проявляющиеся симптомы

Прежде чем автомобилист увидит на сканере код ошибки с номером Р0011, что-то должно его подтолкнуть к проведению проверки диагностическим оборудованием.

Ошибка Р0011 относится к числу проблем, при регистрации которых в ЭБУ никаких изменений в поведении автомобиля во время движения может и не происходить.

Это главная проблема, поскольку автомобилист банально не замечает, что машина ведёт себя как-то не так, а потому горящий чек списывает на случайное срабатывание.

Да, изменения слабо заметные, но они есть. В большинстве случаев оптимальный режим работы двигателя нарушается, что обусловлено работой распредвала с опережением. Это влечёт за собой небольшое увеличение расхода топлива. Параллельно увеличивается концентрация вредных компонентов в выхлопном газе, который выбрасывается в атмосферу.

Есть и такие машины, при выявлении ошибки Р0011 на которых может наблюдаться нестабильное поведение двигателя при высоких оборотах. Связано это всё с тем же опережением, из-за которого впрыскивается больше топлива, нежели требуется мотору.

При этом всегда в случае возникновения ошибки Р0011 загорается сигнальный индикатор Check Engine на приборной панели автомобиля.

Как минимум этот признак должен подсказать автовладельцу проверить память ЭБУ. Учитывая нынешние технологии, во многих случаях проверка успешно выполняется с помощью смартфона. Если есть в распоряжении сканер, подключитесь к блоку управления с его помощью. При отсутствии таких приспособлений и возможностей придётся ехать в автосервис и платить за услуги диагностики. Но сделать это необходимо.

Диагностика блока управления

Ошибка Р0011 — перестановка распредвала

Причины появляющейся ошибки

Важно выяснить, в результате каких именно неисправностей в памяти электронного блока управления может появляться ошибка Р0011, а на приборном щитке загорается индикатор проверки двигателя.

Код неисправности Р0011

Информация по коду ошибки Р0011

Специалисты и бывалые автомобилисты выделяют несколько возможных причин, которые провоцируют появление именно ошибки с кодом Р0011.

Отталкиваясь от причин, проводятся соответствующие диагностические и ремонтно-восстановительные работы.

Источники:

https://andresanda. ru/tehobsluzhivanie/oshibka-r0011-shevrole-kruz. html

Общие советы :

1) все данные (и виды платежей) — в одной плоской таблице (без каких-либо объединений ячеек) на одном(!) листе. Разделы «по счету», «по счетчику(по факту)» и «контроль» — это просто дополнительные столбцы справа.

2) вверху оставьте 10 строк для формул «итого», они всегда видны, т.к. область с формулами» закреплена»  

3) Долг и переплата — это всегда одна строка,  переплату можно ставить красным (формат ячейки — Отрицательное красным)

4) Из-за перерасчетов задним числом и смены тарифов — «помесячные итоги» не так полезны для анализа, как «нарастающий с начала года» или вообще «с начала времен». Я бы внес все квитки с начала года, добавил к январскому сумму долга/переплаты.  

5) Т.к. квитанция состоит всегда из 5 строк (Эл.Д, Эл.Н, ХВС, Вывоз ТКО, Утилизация ТКО) — то сразу их скопировать на 2 года вперед. Т.к. тариф меняется условного говоря «раз в полгода» и долго действует — сослаться формулами апреля — на март итд. И когда тариф эл. энергии станет не 2,83 а 4 — просто в том месяце перебиваем формулу на значение 4.

6) Нужно освоить функцию =СУММЕСЛИ(). Формула, которая суммирует все Дн. киловатты (по счету, счетчику и разницу) с начала года будет выглядеть так: =СУММЕСЛИ(Вид;’ЭлДень’;ПоСчету)
=СУММЕСЛИ(Вид;’ЭлДень’;ПоСчетчику)
=СУММЕСЛИ(Вид;’ЭлДень’;Отклон)
Чтобы можно было так легко писать и понимать формулы — нужно дать имена столбцам (точнее их диапазонам с 11-й по, скажем, по 71-строку, вперед на 5 лет). Для этой цели часто делают «официальную» шапку таблицы и ниже, через 1 пустую строку — дублируют её же краткой одной строкой «полей», в ней все слова без пробелов «Электроэнергия День кВт.ч» -> «ЭлДень». Понятности это не уменьшит, а вот скорость написания формулы вырастет пятикратно. Имена диапазонов можно тогда не создавать — Calc сам поймет где находится столбец «ЭлДень», с какой ячейки начинается и где заканчивается.

7) Самым левым столбцом делают «Период», вводят дату, скажем 31.01.18, 28.02.18. а в формате ячейки — Январь 18, Февраль 18 итд. После включения автофильтра на строке «полей», отделенной от «шапки» пустой строкой — появятся значки Автофильтра и возможность легко отбирать нужный период или нужный вид платежа в Автофильтре.

8) Чтобы автосуммировать видимое (прошедшее фильтр) — нужно освоить функцию =ПРОМЕЖУТОЧНЫЕ.ИТОГИ(9;СЧЕТ)

Полученная плоская таблица обладает громадным плюсом, она все-в-одном, логически целостна. Если захочется сделать по ней отчет — изучаем Сводные таблицы и диаграммы и делаем их на 2-м листе. Но даже просто =ПРОМЕЖУТОЧНЫЕ.ИТОГИ() даст вам информацию о среднем, максимальном, минимальном значении чего угодно за любой период, который выбирается Автофильтром.

Я плачу раз в полгода (ненавижу этот процесс и очереди, т.к. УК до сих пор работает только через ГРЦ-кассы, безнал никак, руководы УК по доброй российской традиции в федеральном розыске), — то оплату я ввожу одной строкой «между» квитанций (заплатил 10/03 — 45 тыс. руб.) Формула у меняя сама делит сумму одного платежа (45 тыс. руб.) на 108 отдельных чисел (по видам платежей). Это достигается суммированием накопленного долга с остатками долга и пени, пропорциональным делением. УК делает все точно так же, и когда с ними спорю — нахожу понимание. Разбивать 45 тр. на 6 квитанций х 6 видов платежей х 3 вида (недоимка/пеня/перерасчет) = 108 цифр — считаю пустой тратой времени. Учетные программы в УК и ТСЖ делают точно так же.

Понравилась статья? Поделить с друзьями:
  • Состояние ошибки 0хс0000022
  • Состояние sql hy000 код ошибки 1000
  • Состояние ошибки 0хс0000020 как исправить
  • Состояние ошибки 0xc00012f
  • Состояние ошибки 0xc0000428