Smart array p410i in embedded slot ошибка

I have got a brand new hp ProLiant DL380 G6 server with embedded smart array P410i controller, I got 146 GB SAS drives and wanted to change them with 300 GB SAS drives before installation. Now, we replace the drives and begin the configuration with the hp DVD and begin; when we reach the point that we want to save the configurations, an error message appears:

«The operation has failed with an unknown error, please restart the application and attempt the operation again»

When using Rescan System, this error message appears:

     "Status Alerts -
      Smart Array P410i in Embedded Slot

      Warning Status Message

      Code   Description
      347    The cache for Smart Array P410i Embedded Slot is not configured"

I return back to the 146 GB SAS drives and the message just keeps appearing again.

This server is brand new never used before -was stored on the client office- and I check and found that this model of servers comes with non battery Smart Array controller.
Any help please.

Модераторы: Trinity admin`s, Free-lance moderator`s

Caesar_spb

Junior member
Сообщения: 2
Зарегистрирован: 11 апр 2016, 13:37

Проблема с контроллером Smart Array P410i

Добрый день.
Имеется сервер DL380 G7. В нем стоит вышеобозначенный контроллер. Прямо вот сейчас сервер остановить не получается — крутятся базы 1С. В ACU про статус контроллера пишут, что «351 Smart Array P410i in Embedded Slot CACHE STATUS PROBLEM DETECTED: The cache on this controller has a problem. To prevent data loss, configuration changes to this controller are not allowed. Please replace the cache to be able to continue to configure this controller. «

Соответственно посмотреть статус дисков нет никакой возможности, а индикатор на одном из дисков как раз горит желтым предупреждающим светодиодом.

Вопрос в следующем — к чему готовиться? Гарантия на сервер кончилась, расширенную не покупали…


Аватара пользователя

Tert

Advanced member
Сообщения: 4233
Зарегистрирован: 19 янв 2003, 08:09
Откуда: Москва
Контактная информация:

Re: Проблема с контроллером Smart Array P410i

Сообщение

Tert » 11 апр 2016, 19:39

Caesar_spb
По моему основные проблемы с кешем контроллера. Выключите сервер, вытащите плату с кешем и почистите контакты. Если проблема не исчезнет, то скорее всего модуль кеша надо менять.


Caesar_spb

Junior member
Сообщения: 2
Зарегистрирован: 11 апр 2016, 13:37

Re: Проблема с контроллером Smart Array P410i

Сообщение

Caesar_spb » 12 апр 2016, 01:08

2 Tert

Спасибо, примерно в этом направлении и думал. Дождался вечера, съездил в офис, вытащил плату кэша и почистил контакты. Результат остался прежним — не изменилось ничего. Попробую у кого-нибудь из знакомых взять такой же кэш на прокат и проверить.


Вернуться в «Массивы — Технические вопросы, решение проблем.»


Перейти

  • Серверы
  • ↳   Серверы — Конфигурирование
  • ↳   Конфигурации сервера для 1С
  • ↳   Серверы — Решение проблем
  • ↳   Серверы — ПО, Unix подобные системы
  • ↳   Серверы — ПО, Windows система, приложения.
  • ↳   Серверы — ПО, Базы Данных и их использование
  • ↳   Серверы — FAQ
  • Дисковые массивы, RAID, SCSI, SAS, SATA, FC
  • ↳   Массивы — RAID технологии.
  • ↳   Массивы — Технические вопросы, решение проблем.
  • ↳   Массивы — FAQ
  • Майнинг, плоттинг, фарминг (Добыча криптовалют)
  • ↳   Proof Of Work
  • ↳   Proof Of Space
  • Кластеры — вычислительные и отказоустойчивые ( SMP, vSMP, NUMA, GRID , NAS, SAN)
  • ↳   Кластеры, Аппаратная часть
  • ↳   Deep Learning и AI
  • ↳   Кластеры, Программное обеспечение
  • ↳   Кластеры, параллельные файловые системы
  • Медиа технологии, и цифровое ТВ, IPTV, DVB
  • ↳   Станции видеомонтажа, графические системы, рендеринг.
  • ↳   Видеонаблюдение
  • ↳   Компоненты Digital TV решений
  • ↳   Студийные системы, производство ТВ, Кино и рекламы
  • Инфраструктурное ПО и его лицензирование
  • ↳   Виртуализация
  • ↳   Облачные технологии
  • ↳   Резервное копирования / Защита / Сохранение данных
  • Сетевые решения
  • ↳   Сети — Вопросы конфигурирования сети
  • ↳   Сети — Технические вопросы, решение проблем
  • Общие вопросы
  • ↳   Обсуждение общих вопросов
  • ↳   Приколы нашего IT городка
  • ↳   Регистрация на форуме

I have got a brand new hp ProLiant DL380 G6 server with embedded smart array P410i controller, I got 146 GB SAS drives and wanted to change them with 300 GB SAS drives before installation. Now, we replace the drives and begin the configuration with the hp DVD and begin; when we reach the point that we want to save the configurations, an error message appears:

«The operation has failed with an unknown error, please restart the application and attempt the operation again»

When using Rescan System, this error message appears:

     "Status Alerts -
      Smart Array P410i in Embedded Slot

      Warning Status Message

      Code   Description
      347    The cache for Smart Array P410i Embedded Slot is not configured"

I return back to the 146 GB SAS drives and the message just keeps appearing again.

This server is brand new never used before -was stored on the client office- and I check and found that this model of servers comes with non battery Smart Array controller.
Any help please.

Студворк — интернет-сервис помощи студентам

Сервер HP DL380 G6, контроллер Smart Array P410i, RAID 5(3 активных диска, 1 spare), 1 логический раздел.
В один прекрасны день на сервере индикация дисков стала следующей(обозначу диски а,б,в,г(spare), как идут по порядку).
1а.-
2а.зелёный
1б.жёлтый
2б.зелёный
1в.-
2в.жёлтый
1г.-
2г.зелёный

Заменить диски на тот момент было проблематично.
Сервер прилично тормозил, было предложено достать диск «в» и вставить обратно, вдруг поднимется.
Так и произошло, индикатор 2в стал зелёным.
То есть были активны все 4 диска. Коллега сделал ребилд, система более менее работала.
Решили также сделать и с диском «б», как оказалось фатальная ошибка ибо прошло менее двух часов с момента прошлой операции с диском «в». Сервер выпал из сети, загорелись следующие индикаторы
1а.-
2а.зелёный
1б.-
2б.зелёный
1в.-
2в.зелёный
1г.-
2г.-

Было решено перезагрузить сервер(на следующее утро), но после перезагрузки он не хотел вновь инициализировать массив. Итог следующая ошибка при инициализации:

1779-Slot 0 Drive Array — Replacement drive(s) detected OR previously failed drive(s) now appear to be operational:
Port 1I: Box 1 :Bay 2,3
Logical Drive(s) disabled due to possible data loss.
Select F1 to continue with logical drive(s) disabled
Select F2 to accept data loss and to re-enable logical drive(s)

Ошибки дисков и логического раздела из ACU:

Consolidated Error Report:
Controller: Smart Array P410i in Embedded Slot
Device: Physical Drive 1I:1:2
Message: Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
Controller: Smart Array P410i in Embedded Slot
Device: Physical Drive 1I:1:3
Message: Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
Controller: Smart Array P410i in Embedded Slot
Device: Logical Drive 1
Message: Logical drive state: This logical drive has failed and cannot be used. All data on this logical drive has been lost.

Заменили диск «в» на новый, запустили сервер заново не помогло, пропала индикация с диска «в», при возврате старого на место та же ситуация, индикация не появляется(возможно требуется какая либо дополнительная операция).
1а.-
2а.зелёный
1б.-
2б.зелёный
1в.-
2в.-
1г.-
2г.-

Если зайти через F8 в настройки контроллера, статус массива и дисков ОК.

Честно скажу, в работе массивов разбираюсь очень слабо(не кидайтесь тряпками), единственное что мне кажется логичным сделать, это нажать F2, так как диски вроде как ещё живы(хоть и в плохом состоянии). Стоит ли нажимать F2 и с каким диском(старым «в» диском или заменить его на новый)?
И есть ли ещё какие-либо советы, кроме того, чтобы учиться работать с массивами?
Заранее спасибо за любой совет и внимание!

Понравилась статья? Поделить с друзьями:
  • Smart agent ошибка эцп
  • Smtp ошибка message size exceeds server limit перевод
  • Smtp ошибка 554 невозможно добавить получателя
  • Smtp ошибка 551
  • Smart 07 частота ошибок позиционирования