Sm 100 ошибка e19

All manuals and user guides at all-guides.com

SM100

9. SM100 ERROR MESSAGE

ERROR MESSAGE

The machine beeps and following error messages appear on display, if incorrect

operation is performed.

No.

Error Message

1

PAPER END

2

FEED PAPER FIRST

3

PEEL LABEL

4

CHANGE PAPER

6

NON PRINT

7

UNIT PRICE OVERFLOW

9

NON LABEL

12

MEMO NOT INITIALIZED

14

HEAD IS NOT CLOSED

16

FILE MEMORY FULL

18

PLEASE REMOVE WEIGHT

19

PLU NOT EXIST

20

TOTAL PRICE IS 0

24

WEIGHT OF

26

TOTAL PRICE OVERFLOW

29

PLEASE SET TARE VALUE

39

PLEASE PRESS PLU KEY

44

KEY ALREADY ASSIGNED

48

PLU DATA INVALID

49

QTY OF

54

BELOW MIN WEIGHT

57

PRICE ACC OF

59

PLEASE SEE LABEL QTY

61

GRAND TOTAL OF

71

PRINT INHIBITED

74

SELF SERVICE MODE

95

CAL00 ERROR

96

CALSP ERROR

97

FORMAT ERROR

98

NO DATA IN REPORT

99

EXCEED WEIGHT QUOTA

Causes

Label sensor sense no label. No more labels. Replace

label roll

Label miss feed, press FEED key to align label.

Peel sensor activated, remove label away from sensor.

Change paper mode between label and receipt.

No manual printing.

Please check unit price.

No free format is programs. Set a free format or use

standard format.

Memory problem. Please clear the memory.

Thermal head no closed. Please close thermal head.

Not enough memory. Expand memory or delete

unnecessary data.

Fixed price item, please remove weigh.

No such PLU data or number exists.

No total price for item. Unit price, weight or quantity is

0.

Weight over maximum capacity when print.

Total price over the limit to display or print.

When force tare is enable, a tare weight must be entered.

Press PLU(#) key. To save data in some procedure.

Preset key already been assigned with function or PLU.

U1 only. Quantity setting incorrect when using FOR.

Quantity data over the limit.

Weight is below min weight set when printing.

Accumulated quantity over the limit.

Set print label quantity when the function is use.

Grand total price over the limit.

Cannot print weigh item at Prepack mode.

Can only use Self-service procedure only.

Zero point calibration error.

Full scale point Calibration error.

No free format is program.

There is no data in report when printing report.

CN only. Please reset weight quota.

ERROR MESSAGE

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Формат этикетки на digi sm-100 : DIGI

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Формат этикетки на digi sm-100 : DIGI

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Digi sm 100 калибровка датчика этикетки

Войти

Авторизуясь в LiveJournal с помощью стороннего сервиса вы принимаете условия Пользовательского соглашения LiveJournal

Настройка весов DIGI SM-100

IP-адрес весов вводятся следующим образом:
1. Перейти в Z-режим (нажать [(<>)] (круговые стрелки) 4 раза)
2. Удерживая [->0 , набрать 0416 . На дисплее весов отобразится текущий IP-адрес в десятичном виде. Ввести первые три байта нового IP-адреса в десятичном виде. Например, для адреса 200.58.1.178, надо ввести 200058001. Нажать клавишу [PLU] .
3. Удерживая [->0 , набрать 0421 . На дисплее весов отобразится текущий шлюз (gateway) в десятичном виде. Ввести нового шлюза. Нажать клавишу [PLU] .
4. Удерживая [->0 , набрать 0418 . На дисплее весов отобразится текущая маска подсети. По умолчанию это 255.255.255.0 Ввести первые три байта новой маски подсети в десятичном виде. Например, для маски 255.255.0.0, надо ввести 255255000. Нажать клавишу [PLU] . Последний байт маски подсети весов всегда равен нулю. Вернитесь в режим регистрации, последовательно нажимая на клавишу [М] пока на дисплее весов не появятся весовые показания.
5. Ввести последний байт IP-адреса. Для этого войти в режим настроек весов (перейти в Z-режим и, удерживая [->0 , набрать 141 , перейти к 135 -й настройке (нажать 135 [Х] , на дисплее должно появиться SP135). Ввести в десятичном виде значение четвертого байта IP-адреса, нажать [*] , а затем — [PLU] . Для активации введенного IP-адреса выключить и включить весы.
6. После изменения IP-адреса необходимо произвести частичный сброс весов.

Для частичного сброса надо:
1. Перейти в Z-режим (При включенных весах 4 раза нажать на клавишу [(<>)] )
2. Удерживая нажатой кнопку [->0 , набрать 230 . На дисплее появится сообщение “Clear PLU File” .
3. Далее 3 раза нажать нажать кнопку [X] для появления сообщения “Чист. Memory Data” .
Нажать [*] . Подтвердить очистку нажатием кнопки [С] . Появятся черточки. Весы вернутся в Z-режим. Частичный сброс произведен. Выйти из Z-режима.
4. После частичного сброса необходимо установить весы в режим печати на этикетках, для этого нажать одновременно клавиши [->0 и [(<>)] Появится сообщение Работа с Этик.

Установка срока годности, времени и даты вручную:
1. [(<>)] до режима S1, затем [x] до режима S4, затем [*] до режима S4.2, затем [8] , затем биндим клавишу для функции установки срока годности кнопкой, в данном случае [1] на цифровой кодовой клавиатуре.
2. [(<>)] до режима S1, затем [x] до режима S8, редактируем дату и время (переключение му датой и временем кнопка [*] ), подтверждаем кнопкой [*] . Нажать клавишу [PLU] .

Установка сдвига этикеток:
1. [(<>)] до режима Z1
2. Удерживая [->0 , набрать 0514 — Отступы печати от краев

Источник

Формат этикетки на digi sm-100 : DIGI

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Формат этикетки для DIGI SM 100 BS : DIGI

хм. спеков подходящих, вроде бы, нету.
тебе стоит стукнуться в асцн. не удивлюсь, если для 100 существует специальная версия лабелмастера, у которого нулевая точка в другом углу и координаты развернуты конкретно для 100.
как, например, существует специальная версия для рисования этикеток с двумя ценами/суммами

а то сейчас кто-нить поделится, но потом буишь так же мучиться, поправляя что-нибудь

только расскажи, для полного понимания — оно не перевернутым печатает?
а то, может, оно просто ленту с другой намоткой хочет 🙂

Andrew_Konev ➤ хм. спеков подходящих, вроде бы, нету.
тебе стоит стукнуться в асцн. не удивлюсь, если для 100 существует специальная версия лабелмастера, у которого нулевая точка в другом углу и координаты развернуты конкретно для 100.
как, например, существует специальная версия для рисования этикеток с двумя ценами/суммами

а то сейчас кто-нить поделится, но потом буишь так же мучиться, поправляя что-нибудь

только расскажи, для полного понимания — оно не перевернутым печатает?
а то, может, оно просто ленту с другой намоткой хочет 🙂

выглядит она точно так же.

просто для некоторых весов надо, чтобы лента была намотана на катушку вверх ногами.
то есть, если одинаково положить рядом две катушки, то у одной этикетки будут перевернуты.
у хорошего поставщика расходников бывают ленточки и с нормальной намоткой и с перевернутой.

иногда можно просто катушку в весы зарядить вверх ногами, но это надо проверять: бывает, что неправильно заряженная лента как-нибудь неудачно перегибается при протяжке и этикетки начинают отклеиваться внутри весов.
как устроена протяжка у digi100 я уже не помню: привез себе один раз одну штуку, когда только появились, посмотрел, понял что ставить в магазины не буду и отправил обратно.

Источник

Digi sm 100 калибровка датчика этикетки

Начинающий

Группа: Пользователи
Сообщений: 58
Регистрация: 3.1.2010
Из: тбилиси
Пользователь №: 19 757

специальный файл f34.dat для см 100 не нужен- советую скачать прогу lable master-там все предельно просто ,рисуете этикетку и прогрузить весы товарами и этикетой ,только память очиститть перед этим- (частичный сброс)

Сообщение отредактировал sanek84 — 24.2.2010, 8:55

Завсегдатай

Группа: Пользователи
Сообщений: 397
Регистрация: 20.11.2006
Из: Архангельск
Пользователь №: 9 529

Начинающий

Группа: Пользователи
Сообщений: 58
Регистрация: 3.1.2010
Из: тбилиси
Пользователь №: 19 757

а чем грузите?рекомендую сис 2002 поставить-и ей грузить этикету.сделайте отдельный файл(не забывайте этикетка это файл f34.datи еще f38.datфайл текстовых сообщений грузятся оба),почистите путь этикетки спиртом,а еще проверить настройку принтера нажав резеро 516- напряжение резистором выставить 2.5 в

какойто код ошибки выдают?или сообщение после печати?

Завсегдатай

Группа: Пользователи
Сообщений: 397
Регистрация: 20.11.2006
Из: Архангельск
Пользователь №: 9 529

а чем грузите?рекомендую сис 2002 поставить-и ей грузить этикету.сделайте отдельный файл(не забывайте этикетка это файл f34.datи еще f38.datфайл текстовых сообщений грузятся оба),почистите путь этикетки спиртом,а еще проверить настройку принтера нажав резеро 516- напряжение резистором выставить 2.5 в

какойто код ошибки выдают?или сообщение после печати?

Источник

   Привет, друзья! В наш сервисный центр поступила заявка на выездной ремонт весов DIGI SM100. Заказчик сообщил, что имеет весы, в которые не прогружаюется база товаров с ПК.

   Приехав к заказчику, мастер начал разбираться в чем же проблема. В магазине оказался небольшой парк весового оборудования — четверо весов DIGI SM100, двое из которых не «видели» сеть и не пинговались. Первым делом простой перестановкой весов было выяснено, что проблема не в сети — исправные весы имели связь, на местах неисправных. Получается, что проблема в самих весах, «выпавших» из сети.

   Проверим настройки в весах. Нас интересуют несколько параметров: ip-адрес, маска сети, mac-адрес. Чтобы узнать какой ip-адрес имеют весы DIGI SM100 нужно войти в режим отчетов, для этого нажать кнопку [re-fresh] четыре раза, потом зажав кнопку [>0<](re-sero), набрать на клавиатуре 0416. В весах были прописаны адреса 192.168.1.14 и 192.168.1.15.

   Топология сети у заказчика была стандартной для локальной сети. Диапазон локальных адресов начинался с адреса 192.168.1.1. Адреса весов не выходят за диапазон сети, т.е. принадлежат сети, но стоит проверить не дублируются они другими устройствами. Для этого отключаем весы и в командной строке выполняем команду ping 192.168.1.14 и ping 192.168.1.15. Ни с первого, ни со второго адреса ответа не последовало, значит эти адреса свободы и их можно использовать в наших весах.

Как проверить mac-адрес в весах Digi SM100?
   Далее проверяем прописаны ли mac-адреса в весах DIGI SM100, для этого переходим в режим отчетов, нажав кнопку [re-fresh] четыре раза, затем нужно включить служебный режим, нажав один раз таковую кнопку через отверстие в корпусе, в нижней задней части весов. Потом зажав кнопку [>0<] набрать 0612. На дисплее весов появится mac-адрес, он должен совпадать с адресом, указанным на наклейке снизу весов. На наших весах mac-адреса были прописаны верно.

Как проверить маску подсети в весах Digi SM100?
   Проверяем маску подсети в весах DIGI SM100 для этого в режиме отчетов(Z-режим) зажимаем кнопку [>0<] и набираем 0418, маска тоже была верной — 255.255.255.0.

Какие настройки должны быть установлены в весах Digi SM100 для работы по сети?
   Ну что ж, проверив основные настройки сети в весах, следует проверить еще кое-что — это спеки(дополнительные настройки). Для этого в режиме отчетов зажимаем [>0<] и набираем 141. Чтобы перейти к нужной настройке(спецификации) нужно ввести номер настройки с клавиатуры весов и нажать кнопку [X]. Для изменения значения настройки, вводим требуемое значение, потом нажимаем [*], потом [PLU].
Для работы весов по сети Ethernet должно быть установлено: 
SPEC49 – 2 
SPEC50 – 1 
SPEC134 – 0 
SPEC135 — …
<четвертый байт ip-адреса> 
SPEC214-0 (работа со статическим адресом, если адрес раздается сервером, то в спеке 214 должна быть единица).

   Что мы имеем: все настройки, которые отвечают за работу весов в сети, присутствуют, тем не менее весы так и не пингуются. Следующим нашим шагом в такой ситуации будет частичный сброс памяти весов, перезапись настроек, а потом снова частичный сброс(так указано в инструкции). 

Как выполнить частичный сброс памяти в весах Digi SM100?
   Выполняем операцию частичного сброса в весах DIGI SM100, для этого в режиме отчетов(Z-режим) зажимаем [>0<], набираем 230. Три раза нажать клавишу [X] для появления запроса очистки памяти. Нажать [*]. В ответ на вопрос о стирании памяти нажать клавишу [C].

Как ввести ip-адрес в весах Digi SM100?
   Заново прописываем настройки, для этого нужно перейти в Z-режим. Ввести старшую часть IP-адреса весов (удерживая [>0<], набрать 0416, затем ввести цифры 192168001 и нажать PLU. Затем нужно установить значения SPEC 135 (в нашем случае значение этого байта в одних весах 14, в других — 15), для этого в режиме отчетов зажимаем [>0<] и набираем 141. Чтобы перейти к 135-й настройке нужно набрать на клавиатуре 135 и нажать кнопку [X]. Для изменения значения настройки вводим требуемое значение, потом нажимаем [*], потом [PLU]. Вводим 135 [X] 14 [*] [PLU] и 135 [X] 15 [*] [PLU] — для вторых весов. Это — последний байт ip-адреса. И опять делаем частичный сброс.

Как сделать полный сброс памяти в весах Digi SM100?
   Хм, весы по прежнему не видят сеть. Значит будем делать полный сброс, потом запись настроек, потом частичный сброс. Чтобы сделать полный сброс следуем инструкции:

1. нажимаем один раз переключатель SPAN SWITCH он находится снизу на системной плате, к нему есть доступ через отверстие в основании; это отверстие находится в задней части основания.
2. Перейти в Z-режим, четырежды нажав клавишу [re-fresh]. Удерживая [>0<] , набрать 8822.
3. Ввести по запросу код страны 16 (UR-Россия). Нажать [*]. 
4. Подтвердить загрузку SPEC по умолчанию, нажав клавишу [C].
5. Выбрать тип весов (Pole — стойка, Bench — без стойки..) клавишей [X]. Нажать [*] (P-CS).
6. Выбрать максимальный вес (6 кг, 15 кг.) клавишей [X]. Нажать [*].
7. Установить разрешение 1/3000М клавишей [X]. Нажать [*].
8. Нажать клавишу [C] (подтверждение очистки памяти). После очистки выйти из Z-режима.
9. Нажать клавишу [>0<] и не отпуская нажмем [re-fresh] для включения режима печати на этикетках (Работа с Этик.)

   Выполнили полный сброс, заново ввели настройки, потом опять частичный сброс, а весы и ныне там.  Пришлось забрать весы в мастерскую, а на подмену оставить свои весы DIGI SM300, которые после записи сетевых настроек сразу «съели» формат этикетки магазина и базу товаров магазина.
  Ну что ж, продолжим решение проблемы в мастерской.

Аватара пользователя

Гончаров Михаил

Администратор
Сообщения: 183
Зарегистрирован: 12 фев 2014, 17:47
Контактная информация:

Digi SM100, ОШИБКА, пишет постоянно протяните ленту

Решение проблемы:
Необходимо провести калибровку датчика этикеток. Для этого из «Z режима» заходим в 515 SPEC – там нажимаем «*», весы снова выходят в «z-режим». Далее – заходим в 516 SPEC — нажимаем кнопку протяжки ленты, весы проматывают несколько этикеток. Выход, кнопкой «Т». После проведения данной калибровки этикетка стала печататься по одной. (прогонка тоже стала выдавать 1 этикетку). Далее проверяем, если есть необходимость – подгружаем и / или подгоняем этикетку настройкой 514 SPEC. Поскольку мы проводили калибровку ПОСЛЕ частичного сброса – значение 514 SPEC было выставлено в 0. Если вы будете пробовать подобную операцию без частичного сброса – выставьте предварительно 0 в 514 SPEC, чтобы в дальнейшем был запас сдвига этикетки после автокалибровки датчика.

(Ocr-Read Summary of Contents of some pages of the Digi SM–100 Document (Main Content), UPD: 12 May 2023)

  • 10, SM 100 GENERAL 7 MULTIPLLE KEY X ¬ Register the number of Non-Weight products. ¬ Select programming item such as PLU data, Shop Name in S Mode. ¬ Select Report Type in X Mode. ¬ Select Data Transaction Type in Z Mode. CLERK KEY V1~V4 ¬ Accumulate the Total Price. VOID KEY − ¬ Correct the sales data. PLU KEY PLU ¬ Call up PLU da…

  • 66, Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 15 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 234 Sub-total and Grand Total Barcode X 0 Based on Item Barcode 1 Based on Total Barcode 235 Mask Barcode Last Human Readable Check Digit X 0 No 1 Yes 236 Char…

  • 61, Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 10 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 133 Change All PLU Default Format when Default SPEC Change X 0 Yes 1 No 134 Host Communication W 0 No Operation 1 Enable Host Communication …

  • 71, Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 20 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 331 Default ITF for Barcode X 0 Disable 1 Enable 332 ITEM Text (5-16) Print on Total Label X 0 Disable 1 Enable 333 Image at Top Receipt Enter range from 0 to 9…

  • 94, PCFL-1 Operation Guide Shanghai TERAOKA Electronic Co., Ltd. — Technical Support Dept. Tel: +86-21-6408-5151 Fax: +86-21-6408-3468 E-Mail: [email protected] Note: You could set the default folder for save the data received from the scale. 3. Operation 1) receive the data from the scale

  • 16, SM 100 INITIAL SETUP 14 Ü Bubble Adjustment Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above. Bubble

  • 14, SM 100 GENERAL 11 1.7 LABEL TYPE The label diameter range is from 40 to 105 mm. Note : Labels must be winding outwards (on top backing paper) and not inwards (under backing paper) within the core (see diagram above). If labels are wound wrongly, printing problem may result. We do not recommend the use of varnish labels. Label Type Dimension (mm) T1…

  • 30, SM 100 SOFTWARE SETTING 28 3. Download the boot program and update the scale Select menu “F ile->Load File To Programmer Buffer” Open the source file of the boot program (e.g. sm100bv100.hex)

  • 86, SM-100 Traceability Setting Guide Prepare Ü Set SPEC258 to “1” Traceability Programming Operation Display Remark tare weight Unit price/kg price [Mode] [Mode] [Mode] S1 å PLU FILE Enter S mode [3] [4] S34 å COUNTRY FILE Enter country file programming [*] [1] S34.0 1 NO SET Program country No. 1 [*][C][H][I][N][A] S34.1 COUN CHINA Name 5 Program country name “CHINA” [#] S34 å COUNTRY FILE Save Country No.…

  • 82, Digi SM–100 Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 31 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 684 Calibration at 1/5 of the Capacity W 0 Disable 1 Enable Not effective when SPEC615 = 0. 685 Auto Selection Between Two Label Format W 0 Inhibit 1 Allow 686 Rounding …

  • 40, SM100 ADJUSTMENT 38 5.3 VOLTAGE CHECKPOINT There are several voltage checkpoints on the PCB boards. Below are some reference voltage points that are commonly use. VOLTAGE POINT VOLTAGE PURPOSE V CC 3.3 V Provide voltage for most of the IC V TH 24 V Provide voltage mainly to the the…

  • 74, Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 23 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 418 Weight Data Synchronization Function X 0 Allow 1 Inhibit 419 Open Cash Drawer when Issue Label X 0 Allow 1 Inhibit …

  • 52, Digi SM–100 Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 1 of 32 TITLE REVISION NO. ISSUED DATE : : : SM-100 SPECIFICATION LIST 0 17 August, 2004 Rev. No. Modification Details Software Version 0 First Release 1.00

  • 63, Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 12 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 175 30 lb to 15 kg Conversion W 0 Disable 1 Enable For UK only. 176 Discount Time on Daily Basis X 0 No 1 Yes 177 Weight Check Function W 0 No 1 Yes 178 Uni…

  • 65, Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 14 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 215 Centering of Special Message X 0 Yes 1 No 216 JIS Code Table W 0 New 1 Old For AA only. 217 Default Label Format 2 for It…

  • 59, Digi SM–100 Specification List SM-100 V2.00 26 December, 2006 2 nd R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 8 of 32 SPEC NO. SPECIFICATION DESCRIPTION SM-100 95 Receipt Printing with Dual Copy W 0 Inhibit 1 Allow 96 Advertisement Message on All Label X 0 Inhibit 1 Allow 97 Manual Print in Prepack Mode …

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Формат этикетки на digi sm-100 : DIGI

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Digi sm 100 калибровка датчика этикетки

Войти

Авторизуясь в LiveJournal с помощью стороннего сервиса вы принимаете условия Пользовательского соглашения LiveJournal

Настройка весов DIGI SM-100

IP-адрес весов вводятся следующим образом:
1. Перейти в Z-режим (нажать [(<>)] (круговые стрелки) 4 раза)
2. Удерживая [->0 , набрать 0416 . На дисплее весов отобразится текущий IP-адрес в десятичном виде. Ввести первые три байта нового IP-адреса в десятичном виде. Например, для адреса 200.58.1.178, надо ввести 200058001. Нажать клавишу [PLU] .
3. Удерживая [->0 , набрать 0421 . На дисплее весов отобразится текущий шлюз (gateway) в десятичном виде. Ввести нового шлюза. Нажать клавишу [PLU] .
4. Удерживая [->0 , набрать 0418 . На дисплее весов отобразится текущая маска подсети. По умолчанию это 255.255.255.0 Ввести первые три байта новой маски подсети в десятичном виде. Например, для маски 255.255.0.0, надо ввести 255255000. Нажать клавишу [PLU] . Последний байт маски подсети весов всегда равен нулю. Вернитесь в режим регистрации, последовательно нажимая на клавишу [М] пока на дисплее весов не появятся весовые показания.
5. Ввести последний байт IP-адреса. Для этого войти в режим настроек весов (перейти в Z-режим и, удерживая [->0 , набрать 141 , перейти к 135 -й настройке (нажать 135 [Х] , на дисплее должно появиться SP135). Ввести в десятичном виде значение четвертого байта IP-адреса, нажать [*] , а затем — [PLU] . Для активации введенного IP-адреса выключить и включить весы.
6. После изменения IP-адреса необходимо произвести частичный сброс весов.

Для частичного сброса надо:
1. Перейти в Z-режим (При включенных весах 4 раза нажать на клавишу [(<>)] )
2. Удерживая нажатой кнопку [->0 , набрать 230 . На дисплее появится сообщение “Clear PLU File” .
3. Далее 3 раза нажать нажать кнопку [X] для появления сообщения “Чист. Memory Data” .
Нажать [*] . Подтвердить очистку нажатием кнопки [С] . Появятся черточки. Весы вернутся в Z-режим. Частичный сброс произведен. Выйти из Z-режима.
4. После частичного сброса необходимо установить весы в режим печати на этикетках, для этого нажать одновременно клавиши [->0 и [(<>)] Появится сообщение Работа с Этик.

Установка срока годности, времени и даты вручную:
1. [(<>)] до режима S1, затем [x] до режима S4, затем [*] до режима S4.2, затем [8] , затем биндим клавишу для функции установки срока годности кнопкой, в данном случае [1] на цифровой кодовой клавиатуре.
2. [(<>)] до режима S1, затем [x] до режима S8, редактируем дату и время (переключение му датой и временем кнопка [*] ), подтверждаем кнопкой [*] . Нажать клавишу [PLU] .

Установка сдвига этикеток:
1. [(<>)] до режима Z1
2. Удерживая [->0 , набрать 0514 — Отступы печати от краев

Источник

Формат этикетки на digi sm-100 : DIGI

Доброго дня, дорогие знатоки.
Обращение к вам — акт признания полного и окончательного проигрыша в битве с настройками адской машиной digi sm-100.

Анамнез:
1. Весы БУ digi sm100 со стойкой.
2. Полный сброс сделан
3. Пингуются, через sis 2002 идеально грузит товары, бегущую строку, ингредиенты, прочие сообщения — и все это отображается на чеке и на стойке.
4. Так же без ошибок загружает название магазина и формат этикеток. Но этого мы уже не видим — название магазина нет вообще. Этикетки не меняются никак. Т.е. в LM открываю и вижу совершенно иной внешний вид.
5. Лента физически заряжена 58х60. Соответственно этикетку тоже подгружаю Shop_58x60
Ладно. три дня промучилась, забила название магазина в строку ингредиентов и хотела счастливо начать работать.

Выяснилось, что откалиброваны на 3 кг, а на 15. Своих эталонов нету, поехала к единственному мастеру в городке, который называется мастером по ремонту весов.

Весы откалибровал. Норм. Но тут новая печаль — шахматка теперь печатается не один сантим снизу, а посередине этикетки. Как будто формат забит 58х30. Соответственно, информация печатается, но на две этикетки сразу.

Это какой-то кошмар. Кроме вашего форума, объективно вообще некуда обращаться — везти из за 240 км в живой населенный пункт — этой край. И никто не хочет делать при мне. А соответственно, это мне еще раз потом за ними ехать.. Тыщу км..

ЧТО пыталась сделать:
1. круглые стрелки — протяжка. Протягивает несколько этикеток, на последней шахматка посередине.
2. Пыталась войти в sp 514, 515, 516 (по инструкциям с форума) — результаты ноль. Или не правильно захожу, или просто совсем дура. Захожу так: частичный сброс — через 141 в спеки. Там 515 *. Но ввести какое либо значение не дает. Пищит и всё.
Мне кажется я что уже только не делала..
В ТОВАРЕ выбираю этикетку F1. При открытии этой же этикетки в LM — выбираю формат 1.
К весам привязываю.
Протяжку делаю.

ВОПРОС:
1. Как добиться печати названия магазина.
2. Как откалибровать значение размера этикетки спеками или sis.

Источник

Формат этикетки для DIGI SM 100 BS : DIGI

хм. спеков подходящих, вроде бы, нету.
тебе стоит стукнуться в асцн. не удивлюсь, если для 100 существует специальная версия лабелмастера, у которого нулевая точка в другом углу и координаты развернуты конкретно для 100.
как, например, существует специальная версия для рисования этикеток с двумя ценами/суммами

а то сейчас кто-нить поделится, но потом буишь так же мучиться, поправляя что-нибудь

только расскажи, для полного понимания — оно не перевернутым печатает?
а то, может, оно просто ленту с другой намоткой хочет 🙂

Andrew_Konev ➤ хм. спеков подходящих, вроде бы, нету.
тебе стоит стукнуться в асцн. не удивлюсь, если для 100 существует специальная версия лабелмастера, у которого нулевая точка в другом углу и координаты развернуты конкретно для 100.
как, например, существует специальная версия для рисования этикеток с двумя ценами/суммами

а то сейчас кто-нить поделится, но потом буишь так же мучиться, поправляя что-нибудь

только расскажи, для полного понимания — оно не перевернутым печатает?
а то, может, оно просто ленту с другой намоткой хочет 🙂

выглядит она точно так же.

просто для некоторых весов надо, чтобы лента была намотана на катушку вверх ногами.
то есть, если одинаково положить рядом две катушки, то у одной этикетки будут перевернуты.
у хорошего поставщика расходников бывают ленточки и с нормальной намоткой и с перевернутой.

иногда можно просто катушку в весы зарядить вверх ногами, но это надо проверять: бывает, что неправильно заряженная лента как-нибудь неудачно перегибается при протяжке и этикетки начинают отклеиваться внутри весов.
как устроена протяжка у digi100 я уже не помню: привез себе один раз одну штуку, когда только появились, посмотрел, понял что ставить в магазины не буду и отправил обратно.

Источник

Digi sm 100 калибровка датчика этикетки

Начинающий

Группа: Пользователи
Сообщений: 58
Регистрация: 3.1.2010
Из: тбилиси
Пользователь №: 19 757

специальный файл f34.dat для см 100 не нужен- советую скачать прогу lable master-там все предельно просто ,рисуете этикетку и прогрузить весы товарами и этикетой ,только память очиститть перед этим- (частичный сброс)

Сообщение отредактировал sanek84 — 24.2.2010, 8:55

Завсегдатай

Группа: Пользователи
Сообщений: 397
Регистрация: 20.11.2006
Из: Архангельск
Пользователь №: 9 529

Начинающий

Группа: Пользователи
Сообщений: 58
Регистрация: 3.1.2010
Из: тбилиси
Пользователь №: 19 757

а чем грузите?рекомендую сис 2002 поставить-и ей грузить этикету.сделайте отдельный файл(не забывайте этикетка это файл f34.datи еще f38.datфайл текстовых сообщений грузятся оба),почистите путь этикетки спиртом,а еще проверить настройку принтера нажав резеро 516- напряжение резистором выставить 2.5 в

какойто код ошибки выдают?или сообщение после печати?

Завсегдатай

Группа: Пользователи
Сообщений: 397
Регистрация: 20.11.2006
Из: Архангельск
Пользователь №: 9 529

а чем грузите?рекомендую сис 2002 поставить-и ей грузить этикету.сделайте отдельный файл(не забывайте этикетка это файл f34.datи еще f38.datфайл текстовых сообщений грузятся оба),почистите путь этикетки спиртом,а еще проверить настройку принтера нажав резеро 516- напряжение резистором выставить 2.5 в

какойто код ошибки выдают?или сообщение после печати?

Источник

   Привет, друзья! В наш сервисный центр поступила заявка на выездной ремонт весов DIGI SM100. Заказчик сообщил, что имеет весы, в которые не прогружаюется база товаров с ПК.

   Приехав к заказчику, мастер начал разбираться в чем же проблема. В магазине оказался небольшой парк весового оборудования — четверо весов DIGI SM100, двое из которых не «видели» сеть и не пинговались. Первым делом простой перестановкой весов было выяснено, что проблема не в сети — исправные весы имели связь, на местах неисправных. Получается, что проблема в самих весах, «выпавших» из сети.

   Проверим настройки в весах. Нас интересуют несколько параметров: ip-адрес, маска сети, mac-адрес. Чтобы узнать какой ip-адрес имеют весы DIGI SM100 нужно войти в режим отчетов, для этого нажать кнопку [re-fresh] четыре раза, потом зажав кнопку [>0<](re-sero), набрать на клавиатуре 0416. В весах были прописаны адреса 192.168.1.14 и 192.168.1.15.

   Топология сети у заказчика была стандартной для локальной сети. Диапазон локальных адресов начинался с адреса 192.168.1.1. Адреса весов не выходят за диапазон сети, т.е. принадлежат сети, но стоит проверить не дублируются они другими устройствами. Для этого отключаем весы и в командной строке выполняем команду ping 192.168.1.14 и ping 192.168.1.15. Ни с первого, ни со второго адреса ответа не последовало, значит эти адреса свободы и их можно использовать в наших весах.

Как проверить mac-адрес в весах Digi SM100?
   Далее проверяем прописаны ли mac-адреса в весах DIGI SM100, для этого переходим в режим отчетов, нажав кнопку [re-fresh] четыре раза, затем нужно включить служебный режим, нажав один раз таковую кнопку через отверстие в корпусе, в нижней задней части весов. Потом зажав кнопку [>0<] набрать 0612. На дисплее весов появится mac-адрес, он должен совпадать с адресом, указанным на наклейке снизу весов. На наших весах mac-адреса были прописаны верно.

Как проверить маску подсети в весах Digi SM100?
   Проверяем маску подсети в весах DIGI SM100 для этого в режиме отчетов(Z-режим) зажимаем кнопку [>0<] и набираем 0418, маска тоже была верной — 255.255.255.0.

Какие настройки должны быть установлены в весах Digi SM100 для работы по сети?
   Ну что ж, проверив основные настройки сети в весах, следует проверить еще кое-что — это спеки(дополнительные настройки). Для этого в режиме отчетов зажимаем [>0<] и набираем 141. Чтобы перейти к нужной настройке(спецификации) нужно ввести номер настройки с клавиатуры весов и нажать кнопку [X]. Для изменения значения настройки, вводим требуемое значение, потом нажимаем [*], потом [PLU].
Для работы весов по сети Ethernet должно быть установлено: 
SPEC49 – 2 
SPEC50 – 1 
SPEC134 – 0 
SPEC135 — …
<четвертый байт ip-адреса> 
SPEC214-0 (работа со статическим адресом, если адрес раздается сервером, то в спеке 214 должна быть единица).

   Что мы имеем: все настройки, которые отвечают за работу весов в сети, присутствуют, тем не менее весы так и не пингуются. Следующим нашим шагом в такой ситуации будет частичный сброс памяти весов, перезапись настроек, а потом снова частичный сброс(так указано в инструкции). 

Как выполнить частичный сброс памяти в весах Digi SM100?
   Выполняем операцию частичного сброса в весах DIGI SM100, для этого в режиме отчетов(Z-режим) зажимаем [>0<], набираем 230. Три раза нажать клавишу [X] для появления запроса очистки памяти. Нажать [*]. В ответ на вопрос о стирании памяти нажать клавишу [C].

Как ввести ip-адрес в весах Digi SM100?
   Заново прописываем настройки, для этого нужно перейти в Z-режим. Ввести старшую часть IP-адреса весов (удерживая [>0<], набрать 0416, затем ввести цифры 192168001 и нажать PLU. Затем нужно установить значения SPEC 135 (в нашем случае значение этого байта в одних весах 14, в других — 15), для этого в режиме отчетов зажимаем [>0<] и набираем 141. Чтобы перейти к 135-й настройке нужно набрать на клавиатуре 135 и нажать кнопку [X]. Для изменения значения настройки вводим требуемое значение, потом нажимаем [*], потом [PLU]. Вводим 135 [X] 14 [*] [PLU] и 135 [X] 15 [*] [PLU] — для вторых весов. Это — последний байт ip-адреса. И опять делаем частичный сброс.

Как сделать полный сброс памяти в весах Digi SM100?
   Хм, весы по прежнему не видят сеть. Значит будем делать полный сброс, потом запись настроек, потом частичный сброс. Чтобы сделать полный сброс следуем инструкции:

1. нажимаем один раз переключатель SPAN SWITCH он находится снизу на системной плате, к нему есть доступ через отверстие в основании; это отверстие находится в задней части основания.
2. Перейти в Z-режим, четырежды нажав клавишу [re-fresh]. Удерживая [>0<] , набрать 8822.
3. Ввести по запросу код страны 16 (UR-Россия). Нажать [*]. 
4. Подтвердить загрузку SPEC по умолчанию, нажав клавишу [C].
5. Выбрать тип весов (Pole — стойка, Bench — без стойки..) клавишей [X]. Нажать [*] (P-CS).
6. Выбрать максимальный вес (6 кг, 15 кг.) клавишей [X]. Нажать [*].
7. Установить разрешение 1/3000М клавишей [X]. Нажать [*].
8. Нажать клавишу [C] (подтверждение очистки памяти). После очистки выйти из Z-режима.
9. Нажать клавишу [>0<] и не отпуская нажмем [re-fresh] для включения режима печати на этикетках (Работа с Этик.)

   Выполнили полный сброс, заново ввели настройки, потом опять частичный сброс, а весы и ныне там.  Пришлось забрать весы в мастерскую, а на подмену оставить свои весы DIGI SM300, которые после записи сетевых настроек сразу «съели» формат этикетки магазина и базу товаров магазина.
  Ну что ж, продолжим решение проблемы в мастерской.