Puloon lcdm 2000 ошибки

NO

Code

Indication

1

30

GOOD

2

31

NORMAL_STOP

3

32

PICKUP_ERR

4

33

JAM_IN_CRI_UPPER

5

34

OVERFLOW

6

35

EXIT_JAM

7

36

DIVERT_JAM

8

37

RES_TIMEPOT

9

3B

BILL_REQ_ERR

10

3D

BILL_COUNT

11

3E

SENSOR_ERR

12

3F

SENSOR_REJECT

13

40

EXIT_JAM1

14

41

MOTOR_UNRUN

15

42

DIVERT_JAM_RUN

16

43

EJECT_JAM_RUN

17

4C

JAM_IN_CRI_LOWR

18

45

UPPER_CASH_BOX

19

45

UPPER_CASH_BOX

The details

Normal Stop

PICK-UP Error

Jam in the CHK SENSOR 1 / 2 part

Over release of bill

Jam in the EXIT SENSOR part

Jam in the DIV SENSOR part

Incompletion of release in 60 seconds

Request bill quantity is over 20

There is difference in bill data between

EJT SENSOR & EXIT SENSOR

Error in SENSOR

Open status of REJECT TRAY

Dispensed bill fail to arrive at the EXIT

SENSOR within 15 seconds

STOP or low speed of MOTOR

Jam in the DIV SENSOR part

TIMEOUT between DIV SENSOR and

EJT SENSOR

Jam in the CHK SENSOR 3/4 part

No Upper Cash Cassette

No Lower Cash Cassette

LCDM-2000

PULOON Technology Inc.

NO

Code

Indication

1

30

GOOD

2

31

NORMAL_STOP

3

32

PICKUP_ERR

4

33

JAM_IN_CRI_UPPER

5

34

OVERFLOW

6

35

EXIT_JAM

7

36

DIVERT_JAM

8

37

RES_TIMEPOT

9

3B

BILL_REQ_ERR

10

3D

BILL_COUNT

11

3E

SENSOR_ERR

12

3F

SENSOR_REJECT

13

40

EXIT_JAM1

14

41

MOTOR_UNRUN

15

42

DIVERT_JAM_RUN

16

43

EJECT_JAM_RUN

17

4C

JAM_IN_CRI_LOWR

18

45

UPPER_CASH_BOX

19

45

UPPER_CASH_BOX

The details

Normal Stop

PICK-UP Error

Jam in the CHK SENSOR 1 / 2 part

Over release of bill

Jam in the EXIT SENSOR part

Jam in the DIV SENSOR part

Incompletion of release in 60 seconds

Request bill quantity is over 20

There is difference in bill data between

EJT SENSOR & EXIT SENSOR

Error in SENSOR

Open status of REJECT TRAY

Dispensed bill fail to arrive at the EXIT

SENSOR within 15 seconds

STOP or low speed of MOTOR

Jam in the DIV SENSOR part

TIMEOUT between DIV SENSOR and

EJT SENSOR

Jam in the CHK SENSOR 3/4 part

No Upper Cash Cassette

No Lower Cash Cassette

LCDM-2000

PULOON Technology Inc.

  1. Manuals
  2. Brands
  3. Puloon Manuals
  4. Dispenser
  5. LCDM-2000

Manuals and User Guides for Puloon LCDM-2000. We have 1 Puloon LCDM-2000 manual available for free PDF download: Service Manual

Specifications:

1355/1355678-lcdm2000.pdf file (17 Mar 2023)

Accompanying Data:

Puloon LCDM-2000 Dispenser PDF Service Manual (Updated: Friday 17th of March 2023 05:08:59 PM)

Rating: 4.5 (rated by 30 users)

Compatible devices: Vista Series, HG01030A, H-6067, DI-CN-0099, Touchless Express SE-SS-TDP1.3, 133172, PowerCure 400, ORION BEAN DOSER.

Recommended Documentation:

Text Version of Puloon LCDM-2000 Service Manual

(Ocr-Read Summary of Contents, UPD: 17 March 2023)

  • Puloon LCDM-2000 User Manual

  • Puloon LCDM-2000 User Guide

  • Puloon LCDM-2000 PDF Manual

  • Puloon LCDM-2000 Owner’s Manuals

Recommended Instructions: Unicel 4CH-20, 15CM, TY-TP42P8S

  • Sanela SLZN 59ES

    SLD 03: OFF/6/8/12/24/72/168 hod SLD 03: 1 — 80 s.5.AUTOMATICKÉ ČIŠTĚNÍAUTO CLEAN PERIODFACTORY SETTINGS 24 hod.6.DÉLKA AUTOMATICKÉHO ČIŠTĚNÍAUTO CLEAN CYCLE LENGHTFACTORY SETTINGS 1 s. SLD 03: ON / OFF7.ZPĚTNÝ CHOD (JEN PRO GELOVÉ DEZINFEKCE)REVERSE RUN (ONLY FOR GEL DISINFECTION) FACTORY SETTINGS OFFFACTORY SETTINGS — AUTOMATIC1.2.3.4.VlastnostiV …

    SLZN 59ES 8

  • Bunn ULTRA-2

    INSTALLATION & OPERATING MANUALBUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-6644www.bunnomatic.comBUNN®32080.0000 03/03 © 2002 Bunn-O-Matic CorporationULTRA-2 …

    ULTRA-2 23

  • rosseto EZPRO 2

    Assembly Instructions for EZPRO 2/3/5 Unit1. Carefully remove all parts from packaging:• 1-PRO Stand• 1-PRO Base • 1-PRO Tray • 1.5mm Allen Wrench • 2, 3 or 5 PRO ContainersI. Pro Lid, Stainless Steel (1)II. 6WR PRO Silicon Paddle Wheel (2)III. Regular Nozzle (3)IV. Container (4)V. Name Tag (5)VI. PRO Handle (6)VII. Mini 1.5mm Screw for Handle …

    EZPRO 2 3

Operating Impressions, Questions and Answers:

Andreyi

Сообщения: 8
Зарегистрирован: 15 июн 2021, 03:01

Всем привет кто жив)

Проблема следующего характера:
Имеем две платы (зеленого цвета r1.1 r1.2)
На платах одна и та же ошибка 4.1 stop motor
Пробовал заменить шаговый двигатель ничего не вышло.

Ошибка все равно 4.1

Имеется тестовый диспенсер (рабочий)
Переставлял платы туда, тоже самое.
Явная проблема в платах.
Горелых дорожек нет.

Куда копать?


knife

Сообщения: 27
Зарегистрирован: 29 май 2014, 21:00

Сообщение knife » 20 окт 2021, 12:01

Копать в сторону драйвера/контроллера двигателя, проверить сигнал от датчиков двигателя после компаратора.

Andreyi

Сообщения: 8
Зарегистрирован: 15 июн 2021, 03:01

Сообщение Andreyi » 26 окт 2021, 01:36

knife писал(а):Копать в сторону драйвера/контроллера двигателя, проверить сигнал от датчиков двигателя после компаратора.

Спасибо!
Действительно он)
НО теперь встал вопрос где купить его или заказать?
Он по маркировки идет как sla5064/2015 но негде нету такой микрухи :?
Али не выдает такой маркировки


Вернуться в «Диспенсеры купюр»

Кто сейчас на конференции

Сейчас этот форум просматривают: нет зарегистрированных пользователей и 0 гостей

Темы дня

  • 307–917Rev. KSupersedes G and PCN JModel 224-522Basic PumpINSTRUCTIONS-PARTS LISTINSTRUCTIONSThis manual contains importantwarnings and information.READ AND KEEP FOR REFERENCE.SEVERE-DUTY, STAINLESS STEEL10:1 Ratio Standard PumpPAIL, WALL, AND CART MOUNT SYSTEMS66 bar, 6.6 MPa (950 psi) MAXIMUM WORKING PRESSUREModel 224-522, Series ABasic Pump* Model 222-390, Series BPail Mou …

    Series A Water Pump, 29

  • 6$9( 7+,6 0$18$/8OWUD6RIW  :DWHU 6RIWHQHU◆ :DUUDQW◆ 6WDUW 8S  6HWWLQJ 7LPHU◆ +RZ,W:RUNV◆ &DUH 2I◆ 6SHFLILFDWLRQV◆ 5HSDLU 3DUWV6HD UV 5RHEXFN DQG &R  %HYHUO 5RDG +RIIPDQ (VWDWHV ,/  86$2:1(5·60$18$/02′(/ 126&DXWLRQ5HDG DQG )ROORZ …

    625.388200 Other, 36

  • Santint A4/A4B Automatic Dispenser V1.0 0 A4/A4B Automatic Dispenser -100% Recirculation User Manual …

    A4 Series Dispenser, 16

  • SKCZGBNávod na použitíNávod na použitieInstructions for useD/ARUPLESROFRLTNLИнструкция по эксплуатацииGebrauchsanleitungInstrukcja użytkowaniaInstrucțiuni de utilizareInstrucciones de usoMode d’emploiGebruiksinstructiesNaudojimosi instrukcijaAutomatická umyvadlová nerezová směšovací baterie s elektronikou ALS, 24 V DCAutomatic stainless …

    SLU 92N Dispenser, 5

  • Operation Manual and Parts DirectoryGlastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780 800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.comLC66 Pre Mix, Post Mix and JuiCe Pro disPensersSprint Counter top DiSpenSerS© 2007 Glastender, Inc. Rev. 07-30-08Pre-Mix LC66-6-PREPost-Mix LC66-6-LEV …

    LC66-6-LEV Dispenser, 12

  • A Division of Stevens Lee Company1600 Xenium Lane North, Minneapolis, MN 55441-3787Phone (763) 553-1881Technical ManualandReplacement Parts ListMajesticMilk DispensersSpecifications Subject to Change Without Notice.MODEL SK10MAJ …

    SK10MAJ Dispenser, 12

  • Repair-PartsReactor® Reactor®Reactor®2 22Hydraulic HydraulicHydraulicProportioning ProportioningProportioningSystems SystemsSystems334946CENHydraulic, Hydraulic,Hydraulic,Heated, Heated,Heated,Plural PluralPluralComponent ComponentComponentProportioner ProportionerProportionerfor forforspraying sprayingsprayingpolyurethane polyurethanepolyurethanefoam foamfoamand andandpolyu …

    Reactor 2 H-30 Controller, 102

  • I‐1083  Page1of4Rev.A‐40009  8/6/14DEMAOneOpenContainerPortableDispensingUnitOverviewTheDEMAOne(DM1)opencontainerdispensingsystemisbuilttomakecleaningeasierandmoreeffective.TheversatilityandfunctionalityoftheDM1makesthisthenext� …

    One Dispenser, 4

  • 48”6”COMPASSTM TOUCH FREE DiSPEnSER Instructional Guide©2016 Betco CorporationAll Rights Reserved.1001 Brown AvenueToledo, Ohio 43607-012707/2016Item #92299-92The Hand Washing Mode guides user on proper hand washing techniques (Picture A). The dispensers are preset to this mode.Le mode de lavage des mains guide l’utilisateur quant aux techniques de lavage des mains appro …

    COMPASS Dispenser, 2

  • FeaturesRelated ProductsITEM#PROJECTDATEFor current specification sheets and other information, go to www.bunn.com.7/10D3Fresh Mix Dispensers• Space saving narrow 8” (20.3 cm) cabinet width.• Variable speed hopper motors offer a wide range of product mix ratios (.75 to 6.6 grams of powder per second).• Large easy-to-fill translucent hoppers ensure quick and timely …

    FMD-1 Dispenser, 2

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10617
Зарегистрирован: 05 авг 2006, 15:10

PULOON 2000 иногда не выдает купюры по запросу

PULOON 2000 жестко глючит — иногда не выдает купюры по запросу, просто жужжит и ничего не делает, при этом если его дрючить раз за разом на выдачу — может выдать больше чем надо (мегакосяк!!!)

соответсвенно вопрос: какие варианты проблемы? Александр (который дотКом — спасибо ему огромное) подсказал что дело в устаревшей прошивке, я буду это проверять, но может еще есть мысли? что бы десять раз не ездить, сразу все проверить на месте… я не работал раньше с диспенсерами, поэтому по началу подумал что неправильно как то положил деньги — возможно это? сейчас пять раз проверил все — вроде все четко лежало, однако глюк повторился….

так же вопрос — а где у него находится наклейка с номером прошивки, какая на данный момент последняя? и какая с уже известным глюком?

заранее благодарен ~)

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru


miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 09 дек 2012, 16:45

Возможно неисправна муфта,но для начала тест на родном софте… на 2000ом на плате стоит индикатор состояния, инструкция с кодами ошибок есть на сайте сенсиса

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10617
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 10 дек 2012, 00:13

а по прошивке никто не знает? :(

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 10 дек 2012, 12:21

Пулон не любит ветхие купюры , а также очень любит чистоту. По симптомам прошивка не причем, да и нет ее в открытом доступе. только если отдельно мс покупать(в штатах 45 баксов, вроде бы).

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10617
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 10 дек 2012, 13:43

miks писал(а):Пулон не любит ветхие купюры , а также очень любит чистоту.

абсолютно новый аппарат, то есть чистота гарантирована, а «не любит ветхие купюры», ну я бы понял если бы он в отбраковочный карман их скидывал, но не отдавать же по этому поводу их клиентам! какой то п*** если честно, я короче в ужасе, как можно с такой аппаратурой работать интересно? … не, у меня видать какая то серьезная проблема….

ps подскажите номер актуальной прошивки плз, все таки проверю и такой вариант

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 10 дек 2012, 15:55

По LCDM для 2000х Т20Т(других не встречал), для 1000х 016Т9- (до нее встречалась 015i)

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Гость

Сообщение Гость » 13 фев 2013, 06:22

Всем, привет, может кто-то помочь с расшифровкой миганий диода на главной плате, любого диспенсера из Puloon ? В частности у меня ECDM-200

miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 13 фев 2013, 12:42

а чем не устраивают коды ошибок в тестовой программе? У нас в ремонте токо лсдм пока были, по есдм не подскажу.На практике если в тесте все «ок», то девайс всегда работал.Фокусы бывают с солиноидами (тупо залипают, лечится грубой наждачкой) и выход из строя какого нибудь транзистора на плате(тут коды ошибок не помогут). PS другой диспенсер в тестовой программе как положено работает, те выдает по команде? возможно что то пропустил в настройках програмы

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Гость

Сообщение Гость » 13 фев 2013, 18:12

техник который его принёс и до этого тестировал, при включеном nend режиме не положив денег «тестировал», прочитал мануал, проблему решил.

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10617
Зарегистрирован: 05 авг 2006, 15:10

А нужен ли Poolon 2000? Не достаточно ли 1000?

Сообщение HWGuy » 19 фев 2013, 11:57

В один стекер влезает купюр до чорта — пачек 10 по моему — неужели сотнями рассчитаться не достаточно будет? не засунешь же в лотерейник больше 50 тр все равно на выдачу, а такая сумма влезет и в один стекер, к тому же когда много и громко щелкать выдавая кучу купюр, по моему это на неокрепшую психику любителей лотереи хорошо влияет…

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

Chief

Эксперт
Сообщения: 880
Зарегистрирован: 03 апр 2007, 16:09

Сообщение Chief » 19 фев 2013, 13:05

HWGuy писал(а):в один стекер влезает купюр до чорта — пачек 10 по моему — неужели сотнями рассчитаться не достотачно будет? не засунешь же в лотерейник больше 50тр все равно на выдачу, а такая сумма влезет и в один стекер, к тому же когда много и громко щелкать выдавая кучу купюр, по моему это на неокрепшую психику любителей лотереи хорошо влияет…

Не удобно. Особенно если с мир лотореей работаешь.

ЕСЛИ ТЫ *** И ПЛУТ#ПОРУГАЙ СКОРЕЕ ЦУП!

sAt861

участник форума
Сообщения: 59
Зарегистрирован: 24 май 2009, 11:22

Сообщение sAt861 » 19 фев 2013, 13:40

Терминал с двухкассетником меньше зажевывает бабосы+ клиенту приятнее получать выигрыш пятихатками, подумай выиграл 10 000 и получил их сотками — ппц.

Как говорят у нас в Припяти — «не тяни кота за рога».

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10617
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 19 фев 2013, 14:56

sAt861 писал(а):подумай выиграл 10 000 и получил их сотками — ппц.

разве плохо? :)

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

Аватара пользователя

Я

ХХХ
Сообщения: 1407
Зарегистрирован: 09 окт 2007, 12:53

Сообщение Я » 19 фев 2013, 15:06

А как будет «приятно», когда сопрут или вскроют лотошник, а там и сотни, и пятихатки…:( Или на экспертизу изымут прямо с баблом, а там его кучка приличная….:( :(

Вы заблуждаетесь настолько глубоко, что заблуждаетесь даже на счет глубины своего заблуждения.

Я игнорирую Валеру!

Chief

Эксперт
Сообщения: 880
Зарегистрирован: 03 апр 2007, 16:09

Сообщение Chief » 19 фев 2013, 15:09

Я писал(а):А как будет «приятно», когда сопрут или вскроют лотошник, а там и сотни, и пятихатки…:( Или на экспертизу изымут прямо с баблом, а там его кучка приличная….:( :(

Это второй вопрос. Хотя какая разница, буть там 50 тыс. сотнями или другими купюрами. При изъятии терема, можно договориться и … забрать бабло. От вскрытия ничего не спасет.

По первому, конечно плохо. В 95 процентах случая, игроки суют выигрыш обратно в куп. По сотне не так интересно, а по 500 или 1000 уже заманчиво.

ЕСЛИ ТЫ *** И ПЛУТ#ПОРУГАЙ СКОРЕЕ ЦУП!

Аватара пользователя

Я

ХХХ
Сообщения: 1407
Зарегистрирован: 09 окт 2007, 12:53

Сообщение Я » 19 фев 2013, 15:12

Chief писал(а):

Я писал(а):А как будет «приятно», когда сопрут или вскроют лотошник, а там и сотни, и пятихатки…:( Или на экспертизу изымут прямо с баблом, а там его кучка приличная….:( :(

Это второй вопрос.

По первому, конечно плохо. В 95 процентах случая, игроки суют выигрыш обратно в куп. По сотне не так интересно, а по 500 или 1000 уже заманчиво.

Вопрос-то второй, но на данный момент очень актуальный.

Вы заблуждаетесь настолько глубоко, что заблуждаетесь даже на счет глубины своего заблуждения.

Я игнорирую Валеру!

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10617
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 19 фев 2013, 18:14

Первая проблема решилась, была тупняк с корпусом, кривой-косой и купюры застревали на выдаче.

Новая проблема уже на другом пулоне- все хорошо работало и вдруг стал сбрасывать ВСЕ купюры из одного ящика в отстойник, если же увеличить сумму выдачи до номинала второго ящика, все равно продолжает драконить первый номинал. Но если изначально надо выдать второй номинал то все в порядке…. и скидывает купюры из первого по многу, даже если запрос только на одну, прям подряд их сбрасывает, штук по 40-50 или пока они не кончатся

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

Mitka

участник форума
Сообщения: 92
Зарегистрирован: 18 дек 2009, 17:12

Сообщение Mitka » 20 фев 2013, 10:53

по мнению многих кто расставляет лото терминалы, там где установлен двухноминальный диспенсер играют больше. Но действительно опасно набивать двухноминальный диспенсер до отказа, вероятность взлома очень большая.
есть вариант использовать в лотерейных терминалах купюроприемник ресайклером Merkur MD 100 [link]http://kiosks.ru/index.php/product-category/all-spair-parts/bill-validators/[/link] вот например лотерейный терминал в платежном корпусе [link]http://kiosks.ru/index.php/product/kiosk-samoobsluzhivaniya-q-60-twin-dvustoronnij/[/link], но сейчас он работает только под ЛотПромом.

там три номинала на выдачу (в барабане три ячейки по 32 купюры)
и кассета на 400 купюр
достаточно зарядить каждую ячейку по штук 10-15 купюр например 50 рублей, 100 рублей и 500руюлей.

Кстати можно в платежник вставить вставить меркур мд 100 (если руки золотые) и вот тебе лотерейник*)

sAt861

участник форума
Сообщения: 59
Зарегистрирован: 24 май 2009, 11:22

Сообщение sAt861 » 20 фев 2013, 11:04

Все красиво,только как оно по надежности??? Не заметно массового внедрения данного девайса, хотя разговоры про него уже больше года, был бы достойной заменой пулону с кешкодом давно заменили бы и прописали в лотереях во всех.

но сейчас он работает только под ЛотПромом — это почти приговор для него:* :* :*

Как говорят у нас в Припяти — «не тяни кота за рога».

Mitka

участник форума
Сообщения: 92
Зарегистрирован: 18 дек 2009, 17:12

Сообщение Mitka » 20 фев 2013, 11:23

Всё очень просто. лотооператоры типа Мир Лотерей и Электрошанс не хотят заморачиваться, напрягать программеров, они сейчас стригут бабло и им всё равно что у клиентов вскрывают терминалы и тащут бабло из пулонов и купюрников с кассетой на 1500 листов.

по надежности Меркура скажу что в немецких «шпилятеках» в игровых автоматах они работают на ура.
Двухгодичная проверка 500 систем показала, что, в среднем, на 7600 приёмом купюр и 4950 выплат случался соответственно только один сбой в работе. Эти цифры включают ошибки в обращении и попытки манипуляций. Примечание: вышеназванная проверка являлась работой в режиме реального времени и не имела ничего общего с проверкой в лабораторных условиях: с «выглаженными» купюрами,постоянными температурами, низким уровнем влажности и т.д.


Вернуться в «Диспенсеры купюр»

Кто сейчас на конференции

Сейчас этот форум просматривают: нет зарегистрированных пользователей и 0 гостей

Темы дня

NO

Code

Indication

1

30

GOOD

2

31

NORMAL_STOP

3

32

PICKUP_ERR

4

33

JAM_IN_CRI_UPPER

5

34

OVERFLOW

6

35

EXIT_JAM

7

36

DIVERT_JAM

8

37

RES_TIMEPOT

9

3B

BILL_REQ_ERR

10

3D

BILL_COUNT

11

3E

SENSOR_ERR

12

3F

SENSOR_REJECT

13

40

EXIT_JAM1

14

41

MOTOR_UNRUN

15

42

DIVERT_JAM_RUN

16

43

EJECT_JAM_RUN

17

4C

JAM_IN_CRI_LOWR

18

45

UPPER_CASH_BOX

19

45

UPPER_CASH_BOX

The details

Normal Stop

PICK-UP Error

Jam in the CHK SENSOR 1 / 2 part

Over release of bill

Jam in the EXIT SENSOR part

Jam in the DIV SENSOR part

Incompletion of release in 60 seconds

Request bill quantity is over 20

There is difference in bill data between

EJT SENSOR & EXIT SENSOR

Error in SENSOR

Open status of REJECT TRAY

Dispensed bill fail to arrive at the EXIT

SENSOR within 15 seconds

STOP or low speed of MOTOR

Jam in the DIV SENSOR part

TIMEOUT between DIV SENSOR and

EJT SENSOR

Jam in the CHK SENSOR 3/4 part

No Upper Cash Cassette

No Lower Cash Cassette

LCDM-2000

PULOON Technology Inc.

Andreyi

Сообщения: 8
Зарегистрирован: 15 июн 2021, 03:01

Всем привет кто жив)

Проблема следующего характера:
Имеем две платы (зеленого цвета r1.1 r1.2)
На платах одна и та же ошибка 4.1 stop motor
Пробовал заменить шаговый двигатель ничего не вышло.

Ошибка все равно 4.1

Имеется тестовый диспенсер (рабочий)
Переставлял платы туда, тоже самое.
Явная проблема в платах.
Горелых дорожек нет.

Куда копать?


knife

Сообщения: 27
Зарегистрирован: 29 май 2014, 21:00

Сообщение knife » 20 окт 2021, 12:01

Копать в сторону драйвера/контроллера двигателя, проверить сигнал от датчиков двигателя после компаратора.

Andreyi

Сообщения: 8
Зарегистрирован: 15 июн 2021, 03:01

Сообщение Andreyi » 26 окт 2021, 01:36

knife писал(а):Копать в сторону драйвера/контроллера двигателя, проверить сигнал от датчиков двигателя после компаратора.

Спасибо!
Действительно он)
НО теперь встал вопрос где купить его или заказать?
Он по маркировки идет как sla5064/2015 но негде нету такой микрухи :?
Али не выдает такой маркировки


Вернуться в «Диспенсеры купюр»

Кто сейчас на конференции

Сейчас этот форум просматривают: нет зарегистрированных пользователей и 0 гостей

Темы дня

Перейти к контенту

Puloon LCDM-2000 Service Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Service Manual

Service Manual

Model

: LCDM-2000

(Cash Dispensing Module)

Total Page

: 38 pages (including cover)

Date

Version :

PULOON Technology Inc.

:

2001. 12

V2.1

Summary of Contents for Puloon LCDM-2000

  • Page 1
    Service Manual Service Manual Model : LCDM-2000 (Cash Dispensing Module) Total Page : 38 pages (including cover) Date 2001. 12 Version : V2.1 PULOON Technology Inc.
  • Page 2
    2-2. Main Board Connector Layout 3. Error Code & Handling Method 3-1. Error Code & the details 3-2. Handling method according to Error Code 4. Self Diagnostic Mode using PC 4-1. Program Loading 4-2. Setting Procedure 4-3. Program Usage PULOON Technology Inc.
  • Page 3
    LCDM-2000 MAIN CONTROLLER CASH OUT REJECT TRAY CASH CASSETTE(Upper) CASH CASSETTE(Lower) DOUBLE FEEDING AUTO CASH FEEDER DETECTION PULOON Technology Inc.
  • Page 4
    LCDM-2000 Term Specification ˚ ˚ PULOON Technology Inc.
  • Page 5
    LCDM-2000 Cassette Door Door Open Direction Insert Locker Cash Plate Cassette Handle Cash Plate Stopper Cash Plate Handle PULOON Technology Inc.
  • Page 6
    Stopper is automatically closed & opened by backing pushing plate and opening door respectively. 1-3-4. Cash Cassette Base When cash cassette is inserted, the part of transporting open automatically by the function of Cash cassette base which is located in the part of transporting part. PULOON Technology Inc.
  • Page 7
    Bill-End sign will displayed with stopping the unit. There is hole in the front of “Cash Cassette” and detection process is done by this hole. ( Please refer to the layout of sensor for location) PULOON Technology Inc.
  • Page 8
    Feed Module consists of auto cash feeder part , double feeding detection part , diverting mechanism part , cash delivery part and Feature is shown below. Feed motor Note Path (Delivery) Diverter Pick-up Roller(Upper) One-way Roller(Upper) Double Detect Roller (Upper) Pick-up Roller(Lower) One-way Roller(Lower) Double Detect Roller (Lower) PULOON Technology Inc.
  • Page 9
    LCDM-2000 < Auto Cash Feeder >- PULOON Technology Inc.
  • Page 10
    LCDM-2000 Description Function ’ ’ ’ ’ PULOON Technology Inc.
  • Page 11
    LCDM-2000 < Constitution of Thickness Recognition > PULOON Technology Inc.
  • Page 12
    LCDM-2000 Description Function ’ ’ ’ PULOON Technology Inc.
  • Page 13
    LCDM-2000 < Constitution of divergence part > PULOON Technology Inc.
  • Page 14
    LCDM-2000 Description Function ’ ’ ’ ’ ’ ’ PULOON Technology Inc.
  • Page 15
    LCDM-2000 1-4-4. Transportation part < Constitution of Transportation part > PULOON Technology Inc.
  • Page 16
    LCDM-2000 — Segment Name Name ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ PULOON Technology Inc.
  • Page 17
    Note Path (Delivery) (11)REJECT TRAY S/W (14) CASH BOX SENSOR 0 (9) NEAREND (12) RVDT SENSOR 0 SENSOR 0 (1)(2)CHK SENSOR 1/2 (15) CASH BOX SENSOR 1 (10) NEAREND (13)RVDT SENSOR 1 SENSOR 1 (3)(4)CHK SENSOR 3/4 PULOON Technology Inc.
  • Page 18
    LCDM-2000 SENSOR Name Function PULOON Technology Inc.
  • Page 19
    LCDM-2000 1-4-6. Power Transportation part • G1 T3 MOTOR CLUTCH CLUTCH PULOON Technology Inc.
  • Page 20
    LCDM-2000 Name Function PULOON Technology Inc.
  • Page 21
    LCDM-2000 No Load Load TYPE Voltage Current Speed Torque Current Speed FB-806 180mA±1 4800rpm± 1kgf- 2400mA±2 3500rpm ±200rpm 00mA 250rpm 00mA PULOON Technology Inc.
  • Page 22
    LCDM-2000 2. H/W Constitution SENSOR Circuit DIP SWITCH SEGEMENT CPU,ROM,RAM RVDT Circuit Solenoid,Clutch BLDC MOTOR RS232 Communication Circuit 24V  5V Conversion Circuit PULOON Technology Inc.
  • Page 23
    Upper Near End sensor ( Near End 0 ) Upper RVDT ( RVDT 0 ) Wheel sensor BLDC Motor Reject Tray limit switch Lower Clutch ( Clutch 1 ) Divert Solenoid Upper Clutch ( Clutch 0 ) POWER RS232 Communication PULOON Technology Inc.
  • Page 24
    STOP or low speed of MOTOR DIVERT_JAM_RUN Jam in the DIV SENSOR part EJECT_JAM_RUN TIMEOUT between DIV SENSOR and EJT SENSOR JAM_IN_CRI_LOWR Jam in the CHK SENSOR 3/4 part UPPER_CASH_BOX No Upper Cash Cassette UPPER_CASH_BOX No Lower Cash Cassette PULOON Technology Inc.
  • Page 25
    — Is all of bill out from CASH CASSETTE? — Re install of CASH CASSETTE after checking above Management — Check NEAREND SENSOR in case of lack of bill < Normal Insertion of Bills > < Wrong Insertion of Bills > PULOON Technology Inc.
  • Page 26
    — Is idle roller rotation in the GUIDE CASH FEED 2 ASS’Y normal? — Is fixing screw in GUIDE CASH FEED 1 / 2 / 3 ASS’Y normal? — Try again after checking above situation. Management — In case of Jam, Turn a handle shown below PULOON Technology Inc.
  • Page 27
    — Is idle roller rotation status in GUIDE CASH FEED 7 ASS’Y normal? — Try again after checking above situation. Management — Replace ASS’Y in case of roller rotation problem in GUIDE CASH FEED 7 ASS’Y. PULOON Technology Inc.
  • Page 28
    — In case of interference between SHAFT DIVERTER ASS’Y & SHAFT ASS’Y CASH FEED 3, Adjust location of SOLENOID Management PIN( Please refer to below picture) — Replace ASS’Y in case of idle roller rotation problem in GUIDE CASH FEED 7 ASS’Y. PULOON Technology Inc.
  • Page 29
    Note Path (Delivery) (11)REJECT TRAY S/W (14) CASH BOX SENSOR 0 (9) NEAREND (12) RVDT SENSOR 0 SENSOR 0 (1)(2)CHK SENSOR 1/2 (15) CASH BOX SENSOR 1 (10) NEAREND (13)RVDT SENSOR 1 SENSOR 1 (3)(4)CHK SENSOR 3/4 PULOON Technology Inc.
  • Page 30
    REJECT TRAY is not closed -Is the location of REJECT TRAY normal? Check Point — Is the location of CONNECTOR normal? — Insert REJECT TRAY to main body. Management — Connect J20 CONNECTOR in the MAIN PCB. PULOON Technology Inc.
  • Page 31
    LCDM-2000 CODE Detail Stop or low speed of MOTOR — Is any obstacle in Power Transportation part? Check Point — Is the location of CONNECTOR correct? -Try again after checking above situation. Management — Check J15 CONNECTOR. PULOON Technology Inc.
  • Page 32
    LCDM-2000 “ ” PULOON Technology Inc.
  • Page 33
    LCDM-2000 PULOON Technology Inc.
  • Page 34
    LCDM-2000    “ ” PULOON Technology Inc.
  • Page 35
    LCDM-2000 “ ” “ ” “ ” PULOON Technology Inc.
  • Page 36
    LCDM-2000 “ ” “ ” “ ” “ ” “ ” PULOON Technology Inc.
  • Page 37
    LCDM-2000 “ ” “ ” PULOON Technology Inc.
  • Page 38
    LCDM-2000 PULOON Technology Inc.

Puloon LCDM-2000 Service Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Service Manual

Service Manual

Model

: LCDM-2000

(Cash Dispensing Module)

Total Page

: 38 pages (including cover)

Date

Version :

PULOON Technology Inc.

:

2001. 12

V2.1

Summary of Contents for Puloon LCDM-2000

  • Page 1
    Service Manual Service Manual Model : LCDM-2000 (Cash Dispensing Module) Total Page : 38 pages (including cover) Date 2001. 12 Version : V2.1 PULOON Technology Inc.
  • Page 2
    2-2. Main Board Connector Layout 3. Error Code & Handling Method 3-1. Error Code & the details 3-2. Handling method according to Error Code 4. Self Diagnostic Mode using PC 4-1. Program Loading 4-2. Setting Procedure 4-3. Program Usage PULOON Technology Inc.
  • Page 3
    LCDM-2000 MAIN CONTROLLER CASH OUT REJECT TRAY CASH CASSETTE(Upper) CASH CASSETTE(Lower) DOUBLE FEEDING AUTO CASH FEEDER DETECTION PULOON Technology Inc.
  • Page 4
    LCDM-2000 Term Specification ˚ ˚ PULOON Technology Inc.
  • Page 5
    LCDM-2000 Cassette Door Door Open Direction Insert Locker Cash Plate Cassette Handle Cash Plate Stopper Cash Plate Handle PULOON Technology Inc.
  • Page 6
    Stopper is automatically closed & opened by backing pushing plate and opening door respectively. 1-3-4. Cash Cassette Base When cash cassette is inserted, the part of transporting open automatically by the function of Cash cassette base which is located in the part of transporting part. PULOON Technology Inc.
  • Page 7
    Bill-End sign will displayed with stopping the unit. There is hole in the front of “Cash Cassette” and detection process is done by this hole. ( Please refer to the layout of sensor for location) PULOON Technology Inc.
  • Page 8
    Feed Module consists of auto cash feeder part , double feeding detection part , diverting mechanism part , cash delivery part and Feature is shown below. Feed motor Note Path (Delivery) Diverter Pick-up Roller(Upper) One-way Roller(Upper) Double Detect Roller (Upper) Pick-up Roller(Lower) One-way Roller(Lower) Double Detect Roller (Lower) PULOON Technology Inc.
  • Page 9
    LCDM-2000 < Auto Cash Feeder >- PULOON Technology Inc.
  • Page 10
    LCDM-2000 Description Function ’ ’ ’ ’ PULOON Technology Inc.
  • Page 11
    LCDM-2000 < Constitution of Thickness Recognition > PULOON Technology Inc.
  • Page 12
    LCDM-2000 Description Function ’ ’ ’ PULOON Technology Inc.
  • Page 13
    LCDM-2000 < Constitution of divergence part > PULOON Technology Inc.
  • Page 14
    LCDM-2000 Description Function ’ ’ ’ ’ ’ ’ PULOON Technology Inc.
  • Page 15
    LCDM-2000 1-4-4. Transportation part < Constitution of Transportation part > PULOON Technology Inc.
  • Page 16
    LCDM-2000 — Segment Name Name ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ ’ PULOON Technology Inc.
  • Page 17
    Note Path (Delivery) (11)REJECT TRAY S/W (14) CASH BOX SENSOR 0 (9) NEAREND (12) RVDT SENSOR 0 SENSOR 0 (1)(2)CHK SENSOR 1/2 (15) CASH BOX SENSOR 1 (10) NEAREND (13)RVDT SENSOR 1 SENSOR 1 (3)(4)CHK SENSOR 3/4 PULOON Technology Inc.
  • Page 18
    LCDM-2000 SENSOR Name Function PULOON Technology Inc.
  • Page 19
    LCDM-2000 1-4-6. Power Transportation part • G1 T3 MOTOR CLUTCH CLUTCH PULOON Technology Inc.
  • Page 20
    LCDM-2000 Name Function PULOON Technology Inc.
  • Page 21
    LCDM-2000 No Load Load TYPE Voltage Current Speed Torque Current Speed FB-806 180mA±1 4800rpm± 1kgf- 2400mA±2 3500rpm ±200rpm 00mA 250rpm 00mA PULOON Technology Inc.
  • Page 22
    LCDM-2000 2. H/W Constitution SENSOR Circuit DIP SWITCH SEGEMENT CPU,ROM,RAM RVDT Circuit Solenoid,Clutch BLDC MOTOR RS232 Communication Circuit 24V  5V Conversion Circuit PULOON Technology Inc.
  • Page 23
    Upper Near End sensor ( Near End 0 ) Upper RVDT ( RVDT 0 ) Wheel sensor BLDC Motor Reject Tray limit switch Lower Clutch ( Clutch 1 ) Divert Solenoid Upper Clutch ( Clutch 0 ) POWER RS232 Communication PULOON Technology Inc.
  • Page 24
    STOP or low speed of MOTOR DIVERT_JAM_RUN Jam in the DIV SENSOR part EJECT_JAM_RUN TIMEOUT between DIV SENSOR and EJT SENSOR JAM_IN_CRI_LOWR Jam in the CHK SENSOR 3/4 part UPPER_CASH_BOX No Upper Cash Cassette UPPER_CASH_BOX No Lower Cash Cassette PULOON Technology Inc.
  • Page 25
    — Is all of bill out from CASH CASSETTE? — Re install of CASH CASSETTE after checking above Management — Check NEAREND SENSOR in case of lack of bill < Normal Insertion of Bills > < Wrong Insertion of Bills > PULOON Technology Inc.
  • Page 26
    — Is idle roller rotation in the GUIDE CASH FEED 2 ASS’Y normal? — Is fixing screw in GUIDE CASH FEED 1 / 2 / 3 ASS’Y normal? — Try again after checking above situation. Management — In case of Jam, Turn a handle shown below PULOON Technology Inc.
  • Page 27
    — Is idle roller rotation status in GUIDE CASH FEED 7 ASS’Y normal? — Try again after checking above situation. Management — Replace ASS’Y in case of roller rotation problem in GUIDE CASH FEED 7 ASS’Y. PULOON Technology Inc.
  • Page 28
    — In case of interference between SHAFT DIVERTER ASS’Y & SHAFT ASS’Y CASH FEED 3, Adjust location of SOLENOID Management PIN( Please refer to below picture) — Replace ASS’Y in case of idle roller rotation problem in GUIDE CASH FEED 7 ASS’Y. PULOON Technology Inc.
  • Page 29
    Note Path (Delivery) (11)REJECT TRAY S/W (14) CASH BOX SENSOR 0 (9) NEAREND (12) RVDT SENSOR 0 SENSOR 0 (1)(2)CHK SENSOR 1/2 (15) CASH BOX SENSOR 1 (10) NEAREND (13)RVDT SENSOR 1 SENSOR 1 (3)(4)CHK SENSOR 3/4 PULOON Technology Inc.
  • Page 30
    REJECT TRAY is not closed -Is the location of REJECT TRAY normal? Check Point — Is the location of CONNECTOR normal? — Insert REJECT TRAY to main body. Management — Connect J20 CONNECTOR in the MAIN PCB. PULOON Technology Inc.
  • Page 31
    LCDM-2000 CODE Detail Stop or low speed of MOTOR — Is any obstacle in Power Transportation part? Check Point — Is the location of CONNECTOR correct? -Try again after checking above situation. Management — Check J15 CONNECTOR. PULOON Technology Inc.
  • Page 32
    LCDM-2000 “ ” PULOON Technology Inc.
  • Page 33
    LCDM-2000 PULOON Technology Inc.
  • Page 34
    LCDM-2000    “ ” PULOON Technology Inc.
  • Page 35
    LCDM-2000 “ ” “ ” “ ” PULOON Technology Inc.
  • Page 36
    LCDM-2000 “ ” “ ” “ ” “ ” “ ” PULOON Technology Inc.
  • Page 37
    LCDM-2000 “ ” “ ” PULOON Technology Inc.
  • Page 38
    LCDM-2000 PULOON Technology Inc.

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10618
Зарегистрирован: 05 авг 2006, 15:10

PULOON 2000 иногда не выдает купюры по запросу

PULOON 2000 жестко глючит — иногда не выдает купюры по запросу, просто жужжит и ничего не делает, при этом если его дрючить раз за разом на выдачу — может выдать больше чем надо (мегакосяк!!!)

соответсвенно вопрос: какие варианты проблемы? Александр (который дотКом — спасибо ему огромное) подсказал что дело в устаревшей прошивке, я буду это проверять, но может еще есть мысли? что бы десять раз не ездить, сразу все проверить на месте… я не работал раньше с диспенсерами, поэтому по началу подумал что неправильно как то положил деньги — возможно это? сейчас пять раз проверил все — вроде все четко лежало, однако глюк повторился….

так же вопрос — а где у него находится наклейка с номером прошивки, какая на данный момент последняя? и какая с уже известным глюком?

заранее благодарен ~)

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru


miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 09 дек 2012, 16:45

Возможно неисправна муфта,но для начала тест на родном софте… на 2000ом на плате стоит индикатор состояния, инструкция с кодами ошибок есть на сайте сенсиса

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10618
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 10 дек 2012, 00:13

а по прошивке никто не знает? :(

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 10 дек 2012, 12:21

Пулон не любит ветхие купюры , а также очень любит чистоту. По симптомам прошивка не причем, да и нет ее в открытом доступе. только если отдельно мс покупать(в штатах 45 баксов, вроде бы).

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10618
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 10 дек 2012, 13:43

miks писал(а):Пулон не любит ветхие купюры , а также очень любит чистоту.

абсолютно новый аппарат, то есть чистота гарантирована, а «не любит ветхие купюры», ну я бы понял если бы он в отбраковочный карман их скидывал, но не отдавать же по этому поводу их клиентам! какой то п*** если честно, я короче в ужасе, как можно с такой аппаратурой работать интересно? … не, у меня видать какая то серьезная проблема….

ps подскажите номер актуальной прошивки плз, все таки проверю и такой вариант

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 10 дек 2012, 15:55

По LCDM для 2000х Т20Т(других не встречал), для 1000х 016Т9- (до нее встречалась 015i)

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Гость

Сообщение Гость » 13 фев 2013, 06:22

Всем, привет, может кто-то помочь с расшифровкой миганий диода на главной плате, любого диспенсера из Puloon ? В частности у меня ECDM-200

miks

Эксперт
Сообщения: 385
Зарегистрирован: 26 янв 2010, 11:29

Сообщение miks » 13 фев 2013, 12:42

а чем не устраивают коды ошибок в тестовой программе? У нас в ремонте токо лсдм пока были, по есдм не подскажу.На практике если в тесте все «ок», то девайс всегда работал.Фокусы бывают с солиноидами (тупо залипают, лечится грубой наждачкой) и выход из строя какого нибудь транзистора на плате(тут коды ошибок не помогут). PS другой диспенсер в тестовой программе как положено работает, те выдает по команде? возможно что то пропустил в настройках програмы

Ремонт CC SM, Custom,Puloon,Citizen,ЖК мониторов.Запчасти.(495)567-14-67 моб.+79161238910

Гость

Сообщение Гость » 13 фев 2013, 18:12

техник который его принёс и до этого тестировал, при включеном nend режиме не положив денег «тестировал», прочитал мануал, проблему решил.

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10618
Зарегистрирован: 05 авг 2006, 15:10

А нужен ли Poolon 2000? Не достаточно ли 1000?

Сообщение HWGuy » 19 фев 2013, 11:57

В один стекер влезает купюр до чорта — пачек 10 по моему — неужели сотнями рассчитаться не достаточно будет? не засунешь же в лотерейник больше 50 тр все равно на выдачу, а такая сумма влезет и в один стекер, к тому же когда много и громко щелкать выдавая кучу купюр, по моему это на неокрепшую психику любителей лотереи хорошо влияет…

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

Chief

Эксперт
Сообщения: 880
Зарегистрирован: 03 апр 2007, 16:09

Сообщение Chief » 19 фев 2013, 13:05

HWGuy писал(а):в один стекер влезает купюр до чорта — пачек 10 по моему — неужели сотнями рассчитаться не достотачно будет? не засунешь же в лотерейник больше 50тр все равно на выдачу, а такая сумма влезет и в один стекер, к тому же когда много и громко щелкать выдавая кучу купюр, по моему это на неокрепшую психику любителей лотереи хорошо влияет…

Не удобно. Особенно если с мир лотореей работаешь.

ЕСЛИ ТЫ *** И ПЛУТ#ПОРУГАЙ СКОРЕЕ ЦУП!

sAt861

участник форума
Сообщения: 59
Зарегистрирован: 24 май 2009, 11:22

Сообщение sAt861 » 19 фев 2013, 13:40

Терминал с двухкассетником меньше зажевывает бабосы+ клиенту приятнее получать выигрыш пятихатками, подумай выиграл 10 000 и получил их сотками — ппц.

Как говорят у нас в Припяти — «не тяни кота за рога».

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10618
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 19 фев 2013, 14:56

sAt861 писал(а):подумай выиграл 10 000 и получил их сотками — ппц.

разве плохо? :)

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

Аватара пользователя

Я

ХХХ
Сообщения: 1407
Зарегистрирован: 09 окт 2007, 12:53

Сообщение Я » 19 фев 2013, 15:06

А как будет «приятно», когда сопрут или вскроют лотошник, а там и сотни, и пятихатки…:( Или на экспертизу изымут прямо с баблом, а там его кучка приличная….:( :(

Вы заблуждаетесь настолько глубоко, что заблуждаетесь даже на счет глубины своего заблуждения.

Я игнорирую Валеру!

Chief

Эксперт
Сообщения: 880
Зарегистрирован: 03 апр 2007, 16:09

Сообщение Chief » 19 фев 2013, 15:09

Я писал(а):А как будет «приятно», когда сопрут или вскроют лотошник, а там и сотни, и пятихатки…:( Или на экспертизу изымут прямо с баблом, а там его кучка приличная….:( :(

Это второй вопрос. Хотя какая разница, буть там 50 тыс. сотнями или другими купюрами. При изъятии терема, можно договориться и … забрать бабло. От вскрытия ничего не спасет.

По первому, конечно плохо. В 95 процентах случая, игроки суют выигрыш обратно в куп. По сотне не так интересно, а по 500 или 1000 уже заманчиво.

ЕСЛИ ТЫ *** И ПЛУТ#ПОРУГАЙ СКОРЕЕ ЦУП!

Аватара пользователя

Я

ХХХ
Сообщения: 1407
Зарегистрирован: 09 окт 2007, 12:53

Сообщение Я » 19 фев 2013, 15:12

Chief писал(а):

Я писал(а):А как будет «приятно», когда сопрут или вскроют лотошник, а там и сотни, и пятихатки…:( Или на экспертизу изымут прямо с баблом, а там его кучка приличная….:( :(

Это второй вопрос.

По первому, конечно плохо. В 95 процентах случая, игроки суют выигрыш обратно в куп. По сотне не так интересно, а по 500 или 1000 уже заманчиво.

Вопрос-то второй, но на данный момент очень актуальный.

Вы заблуждаетесь настолько глубоко, что заблуждаетесь даже на счет глубины своего заблуждения.

Я игнорирую Валеру!

Аватара пользователя

HWGuy

человек с форума
Сообщения: 10618
Зарегистрирован: 05 авг 2006, 15:10

Сообщение HWGuy » 19 фев 2013, 18:14

Первая проблема решилась, была тупняк с корпусом, кривой-косой и купюры застревали на выдаче.

Новая проблема уже на другом пулоне- все хорошо работало и вдруг стал сбрасывать ВСЕ купюры из одного ящика в отстойник, если же увеличить сумму выдачи до номинала второго ящика, все равно продолжает драконить первый номинал. Но если изначально надо выдать второй номинал то все в порядке…. и скидывает купюры из первого по многу, даже если запрос только на одну, прям подряд их сбрасывает, штук по 40-50 или пока они не кончатся

подключу в армаксе агентов на шлюз, либо субагентов с на самом деле выгодными условиями на сотовую связь
qiwi 2% онлайн. пишите на почту forspamer###bk.ru

Mitka

участник форума
Сообщения: 92
Зарегистрирован: 18 дек 2009, 17:12

Сообщение Mitka » 20 фев 2013, 10:53

по мнению многих кто расставляет лото терминалы, там где установлен двухноминальный диспенсер играют больше. Но действительно опасно набивать двухноминальный диспенсер до отказа, вероятность взлома очень большая.
есть вариант использовать в лотерейных терминалах купюроприемник ресайклером Merkur MD 100 [link]http://kiosks.ru/index.php/product-category/all-spair-parts/bill-validators/[/link] вот например лотерейный терминал в платежном корпусе [link]http://kiosks.ru/index.php/product/kiosk-samoobsluzhivaniya-q-60-twin-dvustoronnij/[/link], но сейчас он работает только под ЛотПромом.

там три номинала на выдачу (в барабане три ячейки по 32 купюры)
и кассета на 400 купюр
достаточно зарядить каждую ячейку по штук 10-15 купюр например 50 рублей, 100 рублей и 500руюлей.

Кстати можно в платежник вставить вставить меркур мд 100 (если руки золотые) и вот тебе лотерейник*)

sAt861

участник форума
Сообщения: 59
Зарегистрирован: 24 май 2009, 11:22

Сообщение sAt861 » 20 фев 2013, 11:04

Все красиво,только как оно по надежности??? Не заметно массового внедрения данного девайса, хотя разговоры про него уже больше года, был бы достойной заменой пулону с кешкодом давно заменили бы и прописали в лотереях во всех.

но сейчас он работает только под ЛотПромом — это почти приговор для него:* :* :*

Как говорят у нас в Припяти — «не тяни кота за рога».

Mitka

участник форума
Сообщения: 92
Зарегистрирован: 18 дек 2009, 17:12

Сообщение Mitka » 20 фев 2013, 11:23

Всё очень просто. лотооператоры типа Мир Лотерей и Электрошанс не хотят заморачиваться, напрягать программеров, они сейчас стригут бабло и им всё равно что у клиентов вскрывают терминалы и тащут бабло из пулонов и купюрников с кассетой на 1500 листов.

по надежности Меркура скажу что в немецких «шпилятеках» в игровых автоматах они работают на ура.
Двухгодичная проверка 500 систем показала, что, в среднем, на 7600 приёмом купюр и 4950 выплат случался соответственно только один сбой в работе. Эти цифры включают ошибки в обращении и попытки манипуляций. Примечание: вышеназванная проверка являлась работой в режиме реального времени и не имела ничего общего с проверкой в лабораторных условиях: с «выглаженными» купюрами,постоянными температурами, низким уровнем влажности и т.д.


Вернуться в «Диспенсеры купюр»

Кто сейчас на конференции

Сейчас этот форум просматривают: нет зарегистрированных пользователей и 0 гостей

Темы дня

green-va » 31 мар 2013, 18:52

Cтолкнулся недавно с таким диспенсером. Идет большая отбраковка из второй кассеты. Кто-то может знает как настраивается DD этого диспенсера?

Re: Отбраковка купюр в Puloon LCDM-2000

virtual_w » 24 апр 2013, 14:07

Не знаю поможет ли тебе, но сам я не так давно мучался с таким же аппаратом дело оказалось в «перекосе» банкноты, покопай в сторону этих датчиков .

  • Профиль
  • ICQ

Источник: bankomatchik.ru

Проблема следующего характера:
Имеем две платы (зеленого цвета r1.1 r1.2)
На платах одна и та же ошибка 4.1 stop motor
Пробовал заменить шаговый двигатель ничего не вышло.

Ошибка все равно 4.1

Имеется тестовый диспенсер (рабочий)
Переставлял платы туда, тоже самое.
Явная проблема в платах.
Горелых дорожек нет.

Токарный центр SKM NL 2000 BM | Чистовая обработка детали

Сообщение knife » 20 окт 2021, 12:01

Копать в сторону драйвера/контроллера двигателя, проверить сигнал от датчиков двигателя после компаратора.

Сообщение Andreyi » 26 окт 2021, 01:36

knife писал(а): Копать в сторону драйвера/контроллера двигателя, проверить сигнал от датчиков двигателя после компаратора.

Спасибо!
Действительно он)
НО теперь встал вопрос где купить его или заказать?
Он по маркировки идет как sla5064/2015 но негде нету такой микрухи
Али не выдает такой маркировки

3 сообщения • Страница 1 из 1

  • Платежные сервисы и системы
  • Процессинг «арМакс»
  • Платежный сервис «КИТ вендинг»
  • Платёжный сервис «Центр Управления Платежами»
  • Платежный сервис «Кенгу24.ру»
  • Платежные системы в России и ближнем зарубежье
  • Платежная система Киви (QIWI): кошелек, терминалы
  • QIWI-кошелек
  • Терминалы Киви (Qiwi)
  • Платежная система CyberPlat (не действует)
  • Претензии и жалобы платежных агентов
  • Платежные терминалы
  • Организационные вопросы платежного бизнеса
  • FAQ по платежному бизнесу
  • Документы
  • Банковские схемы работы платежных терминалов
  • Финансовые и юридические вопросы
  • Драйверы и инструкции для платежных терминалов
  • Диспенсеры купюр
  • ИБП
  • Купюроприемники
  • Купюроприемники CashCode и CashCode GX
  • Купюроприемники MEI
  • Купюроприёмники Innovative Technology
  • Купюроприемники ICT
  • Купюроприемники JCM
  • Купюроприемники Matrix от VTI
  • Корпуса для терминалов
  • Картридеры
  • Модемы и проблемы связи
  • Монетоприемники / хоперы / счетчики монет
  • Принтеры
  • Принтеры Custom
  • Принтеры Citizen
  • Принтеры Star Tup
  • Сенсорные панели и мониторы
  • Сортировщики купюр
  • Сторожевые таймеры
  • Фискальные регистраторы и онлайн-кассы
  • Компьютеры, комплектующие, материнские платы
  • Видеонаблюдение и сигнализация
  • Другие технические вопросы
  • Программы для приема платежей и другое ПО
  • Объявления о продаже / покупке оборудования
  • Автоматизация в разных отраслях
  • Вендинговые автоматы
  • Терминалы самообслуживания для автоматизации торговли / бизнеса
  • Прием коммунальных платежей — автоматизация
  • POS терминалы и системы
  • Форумы на другие темы
  • Общение
  • Платежный сервис «Телепорт»
  • Другие виды бизнеса (чем еще занимаемся)

Кто сейчас на конференции

Сейчас этот форум просматривают: нет зарегистрированных пользователей и 0 гостей

Самодиагностика ошибок на опель омега б.

Источник: kiosks.ru

Puloon LCDM-2000 отбраковывает купюры — что делать?

Puloon LCDM-2000 — один из самых распрастрененных видов диспенсеров выдачи сдачи, применяемых в различных сферах, таких как в вендинговые системы, либо системы оплаты парковки. Так же как и любое устройсво, Puloon LCDM-2000 имеет свои особенности в работе, а так же различные варианты неполадок.

Одной из самых распрастраненных неполадок Puloon LCDM-2000 являеется проблема повышенного сброса (отбраковки) купюр в реджект кассету, причем купюры которые отбраковываются могут быть вполне в хорошем состянии: не иметь признаков замятости, брака или иных внешних повреждений.

Почему же диспенсер Puloon LCDM-2000 сбрасывае купюры в кассету отбраковки?

Причина в 85% случаев легко исправима и не требует вызова мастера по ремонту и может быть исправлена на месте без необходимости снимать диспенсер с главного устройсва (паркомата или т.т.)

Что нужно сделать:

1. Снимите боковую крышку внешней панели диспенсера (на некоторых моделях Puloon LCDM-2000, данная крышка может быть цельная (как на фото), либо разделена условно на два отсека: для верхнего и нижнего яруса )

Puloon LCDM-2000

2. После того, как вы сняли крышку, найдите прижимную пластину и лепесток для распределиельного вала купюр той кассеты, купюры из которого попадают в реджект кассету. Лепесток выглядит так:

LCDM-2000

Возьмите прижимную пластину двумя пальцами, и аккуратно подвигайте ее вверх вниз. В правильном положении, лепесток (который на фото) ВПЛОТНУЮ прилегает к металлической планке, в итоге прижимная пластина (та, к которой крепится лепесток) имеет фиксированное (жесткое) положение (НЕ БОЛТАЕТСЯ)

Если вы обнаружили, что лепесок (на фото) отогнут и вся конструкция, на которой прикреплен лепесток (прижимная пластина), болтается — это и есть причина, по которой не срабатывает счетчик купюр на выдачу.

Вам необходимо загнуть лепесток в ПРАВИЛЬНОЕ ПОЛОЖЕНИЕ так, чтоб констукция на которой крепится лепесток (прижимная пластина) НЕ БОЛТАЛАСЬ (см фото) после этого проблема отработки в реджект кассету исчезнет с вероятностью 85%.

Источник: parklife.pro

Puloon LCDM-2000 Service Manual

Download or Read Puloon LCDM-2000 Dispenser User Guide, Service Manual (38 pages) Online

  • Manufacturer: Puloon
  • Category of Device: Dispenser
  • Document: LCDM-2000 Service Manual, File Type: PDF
  • Updated: 06-06-2022
  • Count of Pages: 38

Puloon LCDM-2000 Service Manual, page 1

Page 1 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 2

Page 2 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 3

Page 3 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 4

Page 4 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 5

Page 5 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 6

Page 6 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 7

Page 7 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 8

Page 8 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 9

Page 9 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 10

Page 10 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 11

Page 11 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 12

Page 12 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 13

Page 13 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 14

Page 14 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 15

Page 15 of Puloon LCDM-2000 Service Manual

Puloon LCDM-2000 Service Manual, page 16

Page 16 of Puloon LCDM-2000 Service Manual

Accompanying Data:

Puloon LCDM-2000 Dispenser PDF Service Manual (Updated: Monday 6th of June 2022 12:09:04 AM)

Rating: 4.3 (rated by 90 users)

Compatible devices: KW268, WD510AS, HBD191, 301B-2EP, VersaBlue, H-7174, EZ-Fit Lid L2200C, PP005.

Recommended documentation for LCDM-2000 device owners:

Источник: guidessimo.com

Полезные файлы

Puloon ECDM-200 техническая документация

Скачать

Puloon LCDM-1000 техническая документация

Скачать

Puloon VCDM техническая документация

Скачать

Контакты

+7 495 204 17 36
info@puloon.ru

График работы

Будние дни: 10:00 — 19:00
Выходные дни: не работаем!

© 2019 puloon.ru © 2009-2019 «Puloon» Диспенсеры купюр


Имя пользователя писал(а):

Здравствуйте, уважаемые знатоки!
Пытаюсь подключить диспенсер банкнот puloon lcdm-2000, но программа отказывается адекватно с ним работать.
Конфигуратор (Версия: 4.2.13) при автосканировании его, похоже, не определяет. Прописал настройки в config.ini, после запуска конфигуратора теперь на вкладке «диспенсера» все параметры указаны верно, но кнопка теста не активна. Симулирую выбор типа диспенсера — клик по выпадающему списку, кнопка теста становится активной, при нажатии на неё выходит сообщение о превышении времени ожидания ответа. И самое интересное, стоит занять com-порт какой-либо сторонней программой (putty, фирменная утилита LCDM_INT) и освободить, даже не отправляя в порт никакой информации, так сразу же диспенсер начинает реагировать на кнопку теста и появляется сообщение,что тест пройден,всё хорошо. Этот трюк срабатывает только при уже запущенном конфигураторе. Если «передёрнуть» порт, а затем запустить конфигуратор, то результата нет.
Вот краткая вырезка error.log

Код:

Info; Config. Отправка команды юя в порт \.COM1. Скорость: 9600. Устройство:
Info; Config. Отправка команды PD в порт \.COM1. Скорость: 9600. Устройство:
Info; Config. Ответ от порта COM\.COM1. На скорости: 9600. . Диспенсер Poolon (LCDM-1000/LCDM-2000)
Info; Config. Ответ от порта COM\.COM1. На скорости: 9600. . Диспенсер Poolon (LCDM-1000/LCDM-2000)
Info; Конец опроса устройства. Диспенсер Poolon (LCDM-1000/LCDM-2000). Порт: 1. Скорость: 9600
Info; Config. COM 1 не ответил за отведенное время!
Info; Config. Начало завершения сканирования порта
Info; Config. Завершение сканирования порта COM1

Пробовал autoscan=0 в config.ini, ничего не меняется.
Соответственно, в самой программе (Total=4.2.2.10b T.exe=4.2.2.9b) диспенсер не проявляет признаков существования. Я так понимаю в сервисном меню, после снятия стекера, на вкладке «работа с терминалом» должна появиться кнопка «диспенсер».
А теперь вопросы. Насколько вообще реализована функция выдачи сдачи через диспенсер, может быть, напрасна вся эта затея изначально? Возможно ли заменить оплату других услуг на сдачу исключительно выдачей через диспенсер? И что я делаю не так, почему устройство не хочет дружить с программой?

Здравствуйте, Константин!
Чтобы воспроизвести Вашу ситуацию нам нужны ваши файлы настроек. Т.е. это пока это config.ini и error.log для анализа.
Можете присылать эти файлы на

support@paypro.ru или прямо мне на dv@paypro.ru
Вообще кнопка «Тестировать» на вкладке «Устроства->Диспенсер» становится активной в том случае, если установлена галочка «Использовать диспенсер» и выбран Тип диспенсера (протокол).
Конечно с изменением настройки autoscan=0 в config.ini конфигуратор просто ничего не сканирует в автоматическом режиме, и Вам нужно устанавливать все вручную. Другое дело почему он не находит устройство в при autoscan=1. Дело в том, что конфигуратор переделывался и переделывалась очень сильно функция автосканирования и что-то может не работать. К сожаления протестировать данное устройство, а именно диспенсер, возможности не было.
Теперь я задам Вам вопрос.
Вы описали «трюк» с COM-портом. Вы пишете, что после передергивания порта и запуска конфигуратора, порт не реагирует. Но в тоже время у Вас получается добиться ответа при запущенном конфигурторе. А Вы не пробовали «передернуть» порт, открыть его другой программой например (putty, фирменная утилита LCDM_INT) и освободить, а затем открыть конфигуратор? Будет ли в таком случае реагировать порт?
Далее. В фирменной утилите диспенсер нормально определятся и работает? На каком порту и какой скорости? Пробовали ли Вы просто взять настройки из фирменной утилиты не нажимая кнопку «Тестировать» в конфигураторе? Пробовали после это запускать ПО?
Можете попробовать?

File Specifications:

1355/1355678-lcdm2000.pdf file (14 Mar 2023)

Accompanying Data:

Puloon LCDM-2000 Dispenser PDF Service Manual (Updated: Tuesday 14th of March 2023 07:36:28 PM)

Rating: 4.6 (rated by 65 users)

Compatible devices: TAL-750HD-18, TREA 0060, H-8795, Zippette Digital, MAXIBREW 2, 160-1101 FlexiStore, E01087, IBD44 Series.

Recommended Documentation:

Service Manual (Text Version):

(Ocr-Read Summary of Contents of some pages of the Puloon LCDM-2000 Document (Main Content), UPD: 14 March 2023)

  • Puloon LCDM-2000 User Manual

  • Puloon LCDM-2000 User Guide

  • Puloon LCDM-2000 PDF Manual

  • Puloon LCDM-2000 Owner’s Manuals

Recommended: A1000, BD-HP90S, GX300, 917.364250, PSS-280

Links & Tools

  • A Division of Stevens Lee Company1600 Xenium Lane North, Minneapolis, MN 55441-3787Phone (763) 553-1881Technical ManualandReplacement Parts ListLettuce Crisper/DispenserSpecifications Subject to Change Without Notice.MODEL SK2SB …

    SK2SB 12

  • Installation/Service ManualVANGUARD 245 POST-MIX DISPENSER(Mc DONALD’SR APPLICATIONS)IMPORTANT:TO THE INSTALLER.It is the responsibility ofthe Installer to ensure thatthe water supply to thedispensing equipment isprovided with protectionagainst backflow by an airgap as defined inANSI/ASME A112.1.2-1979;or an appro …

    Cornelius VANGUARD 245 71

  • Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061, New Zealand. PO Box 12 417 Penrose. Auckland 1642. New Zealand. Tel: +64 9 579 2094 Fax: +64 9 579 0635 [email protected] www.compacngv.com Compac Industries Ltd. 52 Walls Road. Penrose. Auckland 1061, New Zealand. PO Box 12 417 Penrose. Auckla …

    CNG 59

  • NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.NOTE: The information in this manual is subject to change at any time without notice. Installations may be performed at di󰀨erent times of construction by di󰀨erent individuals. For this reason, these instructions should be left on-site with the facility or m …

    Z6900-SD-WM 8

Operating Impressions, Questions and Answers:

Понравилась статья? Поделить с друзьями:
  • Push уведомления вк ошибка при включении
  • Puh 8060 tfd ошибка ef
  • Putty сетевая ошибка доступ запрещен
  • Putty сетевая ошибка время ожидания соединения истекло
  • Putty ошибка network error software caused connection abort