Function Description
CPU
Interfaces
CPU interfaces
SafetyBUS p interface
Interfaces for standard bus systems
Inputs
Alarm inputs (DIF)
Outputs
Single-pole outputs (DOT/DOS)
Dual-pole outputs (DOZ)
Configuration coding
Installation
General requirements
Installing the safety system
Installing the safety system PSS 3075-3, PSS 3075-3 NR
Installing the safety system PSS 3075-3 DP-S,
PSS SB 3075-3, PSS SB 3075-3 ETH-2 and
PSS SB 3075-3 ETH-2 SE
Installing the safety system PSS SB 3075-3 DP-S,
PSS SB 3075-3 CANopen and PSS SB 3075-3 ETH-2 CANopen
Installing the safety system in a control cabinet
Supply Voltage
General requirements
Notes on wiring
2
Operating Manual: PSS 3075-3 Series
4-1
4-1
4-1
4-1
4-1
4-1
4-2
4-2
4-2
4-3
4-3
4-7
4-8
5-1
5-1
5-1
5-2
5-3
5-4
5-5
6-1
6-1
6-3
Table of Contents
Previous Page
Next Page
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
Show Quick Links
- Quick Links:
-
Pss 3075-3, Pss 3075-3 Nr
-
Alarm Inputs (Dif)
-
Faults
Hide quick links:
Advertisement
Related Manuals for Pilz PSS 3075-3 Series
-
Controller pilz PSS Series Operating Manual
Programmable safety control (19 pages)
-
Controller Pilz PSS Series Operating Manual
Safety systems; units with two safetybus p interfaces (77 pages)
-
Controller Pilz PSS Series Operating Manual
Programmable safety control (29 pages)
-
Controller Pilz PSS DIO Z Operating Manual
Programmable safety control pss-range (37 pages)
-
Controller Pilz PSSuniversal multi PSSu H m F DP ETH SD Operating Manual
(35 pages)
-
Controller Pilz PKB-M Operating Manual
Electronic braking systems (85 pages)
-
Controller Pilz PNOZ m B0 Operating Manual
Configurable, safe small controllers (41 pages)
-
Controller Pilz PNOZ m EF SafetyNET Operating Manual
Configurable, safe small controllers pnozmulti 2 (27 pages)
-
Controller Pilz PSEN sl-0.5p 1.1 Operating Manual
(35 pages)
-
Controller Pilz PNOZ m B1 Operating Manual
Configurable, safe small controllers pnozmulti 2 (39 pages)
-
Controller Pilz PNOZ mc1p Operating Manual
(18 pages)
-
Controller Pilz PSEN sl-0.5n 1.1 Operating Manual
(32 pages)
-
Controller Pilz PNOZ m EF Multi Link Operating Manual
Configurable, safe small controllers pnozmulti 2 (23 pages)
-
Controller Pilz PNOZ mmc3p Manual
Configurable, safe compact controllers (21 pages)
-
Controller Pilz 20 748-03 Operating Manual
Programmable safety systems pss-range pss sb active junction basis (16 pages)
-
Controller Pilz PNOZ mm0p Operating Manual
Safety, configurable control system pnozmulti (43 pages)
Related Products for Pilz PSS 3075-3 Series
- Pilz PSS SB CPU
- Pilz PSS SB2 3006-3 CN-A
- pilz PSS1 PS 24
- Pilz PSS DI
- Pilz PSS1 DI
- Pilz PSS DIO Z
- Pilz PSS1 DIO Z
- Pilz PSSuniversal multi PSSu H m F DP ETH SD
- Pilz PIT es6 Series
- Pilz PIT esb6.16
- Pilz PIT es6.10
- Pilz PNOZ m EF SafetyNET
- Pilz PNOZ m ES
- Pilz PMotion
- Pilz PIT js2 bc
- Pilz PIT esb6.13
Modular Block System: Emergency Stop Circuits
6-25
The acknowledgements
FbL1 and FbL2 are also monitored in the static
condition. If there are discrepancies between the set and true condition, an
error message will be issued (
ENBL = 0) and the contactors will be
switched off immediately (
K1 = 0 and K2 = 0). The error will need to be
reset.
It is possible to reset errors via the input parameter
RSET both when ON =
0 and when
ON = 1. However, a prerequisite for setting the enable and,
when
ON = 1, switching on the contactors, is that the signals from the
feedback loops are correct.
Error messages
Any fault that is detected will be stored in the corresponding error data
word (
SSNR) of the administration data block (1st data block), until the
fault has been fully dealt with.
• Error messages in the administration data block
— Bit 00:
Fault as the signal changes at input parameter
ON,
feedback loop 1 (
FbL1) remains open
Remedy: Check contactor, contacts, cable, input card, output
card, value of input parameter
TFbL and all conditions and
then reset (input parameter
RSET)
— Bit 01:
Fault as the signal changes at input parameter
ON,
feedback loop 1 (
FbL1) remains closed
Remedy: Check contactor, contacts, cable, input card, output
card, value of input parameter
TFbL and all conditions and
then reset (input parameter
RSET)
— Bit 02:
Fault as the signal changes at input parameter
ON,
feedback loop 2 (
FbL2) remains open
Remedy: Check contactor, contacts, cable, input card, output
card, value of input parameter
TFbL and all conditions and
then reset (input parameter
RSET)
Table of Contents for Pilz PSS 3075-3 Series:
-
1Operating Manual: PSS 3075-3 Series Introduction 1-1 Validity of documentation 1-2 Overview of documentation 1-3 Definition of symbols 1-4 Overview 2-1 Front views 2-4 PSS 3075-3, PSS 3075-3 NR 2-4 PSS 3075-3 DP-S 2-6 PSS SB 3075-3 2-8 PSS SB 3075-3 DP-S 2-10 PSS SB 3075-3 ETH-2, PSS SB 3075-3 ETH-2 SE 2-12 PSS SB 3075-3 CANopen 2-14 PSS SB 3075-3 ETH-2 CANopen 2-16 Safety 3-1 Intended us
-
Function Description 4-6 Operating Manual: PSS 3075-3 Series Block SB255 DB003 DB001 Input FUNK = 2 DW200 DW201 DW202 Output ERG = 1 DW200 Key Deactivate output power-up test in bits Function performed without error Incorrect SB255 calls will lead to a STOP condition Slot number on the PSS 3075-3 series: 2 / 4 Masks for outputs 2.00 … 2.15 / 4.00 … 4.15 If this is set on a bit belonging to an output, the power-up test for this output will be deactivated. For example: 0101 H
-
Operating Manual: PSS 3075-3 Series 8-7 User interface RS 485 A detailed description of the interface can be found in the “FS System Description” and “ST System Description” in the PSS-range manual package. The RS 485 interface has internal termination: 120 Ohm between A and B, 270 Ohm between A and 5 V and between B and GND. The termination on the RS 485 user interface can be switched off. To do this, press the R T (USER)
-
5-1Operating Manual: PSS 3075-3 Series General requirements Please note the following: • The safety system should be installed in an enclosure, e.g. control cabinet, that conforms to the protection class required for the environment. • When installing the system in an enclosure such as a control cabinet, the environmental data for the safety system must be taken into account. Details can be found in the chapter entitled “Technical Details”.
-
Operation and Maintenance 9-4 Operating Manual: PSS 3075-3 Series Fig. 9-1: Changing the battery, part 1 (example: PSS 3075-3) CAUTION! Adverse effect on the safety functions! Please ensure that no metal parts get into the open PSS system, as this could adversely affect the system’s safety functions. Please proceed with care! Switch off the supply voltage, remove connector and terminal blocks. Remove the cap from the “F-STACK” button.
-
Operating Manual: PSS 3075-3 Series 7-3 — If there are potential sources of interference, screened cables will be required for connecting alarm signals to the alarm inputs (DIF) and, if the alarm inputs are pulsed, for supplying the test pulses. If necessary, the supply to the system can be buffered. — When switching inductive loads, suppression should not be used to protect the semiconductor outputs. Errors may occur if suppression cannot be avoided (e.g. on contactors with integral suppression), particulary with RC elements, depending on their capacitive share
-
Operation and Maintenance 9-2 Operating Manual: PSS 3075-3 Series Display elements PSS functionality LED RUN ST RUN FS POWER Digital inputs/outputs Signal Off Lights green Off Lights green Flashes green Lights green Off Lights green Key Standard section of PSS in “STOP” Standard section of PSS in “RUN” Failsafe section of PSS in “STOP” Failsafe section of PSS in “RUN” Major error Remedy: Read the error stack, switch off the PSS, rectify the error, switch on the PSS The internal
-
2-1Operating Manual: PSS 3075-3 Series Overview A PSS from the PSS 3075-3 series is a complete programmable safety system in a single unit. The device descriptions provide information on their function. The description are made up of combinations of letters and numbers. • The PSS 3075-3 contains: — Power supply — CPU — 48 digital inputs, 6 of which are alarm inputs — 18 single-pole outputs, 4 of which are test pulse outputs — 9 dual-pole outputs — Programming device interface (combined RS 232/RS 485 interface) — User interface (combined RS
-
Appendix 11-4 Operating Manual: PSS 3075-3 Series Notes
-
Operating Manual: PSS 3075-3 Series 7-9 X1 X2 X3 X4 0 V I 0.8 I 0.9 I 0.10 I 0.11 I 0.12 I 0.13 I 0.14 I 0.15 0 V I 0.0 I 0.1 I 0.2 I 0.3 I 0.4 I 0.5 I 0.6 I 0.7 O -2.17 O +2.17 O 2.15 O/T 2.0 O/T 2.1 O/T 2.2 O/T 2.3 O -2.18 O +2.18 O -2.16 O +2.16 O 2.8 O 2.9 O 2.10 O 2.11 O 2.12 O 2.13 O 2.14 OSSD1 OSSD2 24 V 0 V 24 V DC L+ L- X0 PSS X1/X2 24 V 0 V 24 V 0 V 24 V DC 24 V DC X7 24 V 0 V 24 V DC Dual-channel input device with differ
-
Wiring the Inputs and Outputs 7-20 Operating Manual: PSS 3075-3 Series Dual-pole outputs Features: • 9 dual-pole outputs O1.16 … O1.21, O2.16 … O2.18 • Output current: 2 A • The continuous current over all the outputs must not exceed the following values: — max. total of 10 A at terminals X1 and X2 — max. total of 10 A at terminals X8 and X9 • The operating system on the programmable safety system tests the outputs during each cycle. Any short circu
-
Wiring the Inputs and Outputs 7-16 Operating Manual: PSS 3075-3 Series Alarm inputs (DIF) Example: Alarm test Features: • The test pulse must be allocated to the input in the system software’s PSS Configurator (e.g. PSS WIN-PRO). • The alarm inputs on the programmable safety system have a shorter filter time than the other inputs on the safety system. The test period will automatically adjust to the alarm inputs. • DIF and DI2 inputs must not be connected to the same test pul
-
1-3Operating Manual: PSS 3075-3 Series Overview of documentation 1 Introduction The introduction is designed to familiarise you with the contents, structure and specific order of this manual. 2 Overview This chapter provides information on the most important features of the programmable safety systems. 3 Safety This chapter must be read as it contains important information on safety regulations and intended use. 4 Function Description This chapter describes the individual components of th
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of Pilz PSS 3075-3 Series device using right now.
Specifications:1385/1385934-pss_30753_series.pdf file (09 Dec 2022) |
Accompanying Data:
Pilz PSS 3075-3 Series Controller PDF Manual (Updated: Friday 9th of December 2022 06:34:47 AM)
Rating: 4.8 (rated by 59 users)
Compatible devices: PSS Series, 20 748-03, PSEN sl-0.5p 1.1, PSEN sl-0.5n 1.1, PSEN op67-69K Series, PNOZ mm0p, PIT es6 Series, PNOZ m EF 1MM.
Recommended Documentation:
Text Version of Pilz PSS 3075-3 Series Manual
(Ocr-Read Summary of Contents, UPD: 09 December 2022)
-
73, Operating Manual: PSS 3075-3 Series 8-1 General requirements We recommend you use screened cable for the RS 232/RS 485 interfaces. If unscreened cables are used, the interfaces may malfunction. • Earth the cable screening on both sides (e.g. on a bus bar). • If you are using longer cables and there is…
-
69, Operating Manual: PSS 3075-3 Series 7-19 X1 X2 X3 X4 0 V I 0.8 I 0.9 I 0.10 I 0.11 I 0.12 I 0.13 I 0.14 I 0.15 0 V I 0.0 I 0.1 I 0.2 I 0.3 I 0.4 I 0.5 I 0.6 I 0.7 O -2.17 O +2.17 O 2.15 O/T 2.0 O/T 2.1 O/T 2.2 O/T 2.3 O -2.18 O +2.18 O -2.16 O +2.16…
-
67, Operating Manual: PSS 3075-3 Series 7-17 Please ensure safety regulations and EMC guidelines are met! X5 X6 0 V I 1.0 I 1.1 I 1.2 I 1.3 I 1.4 I 1.5 I 1.6 I 1.7 0 V I 1.8 I 1.9 I 3.0 I 3.1 I 3.2 I 3.3 I 3.4 I 3.5 X7 X1 X2 X3 X4 0 V I 0.8 I 0.9 I 0.10 I 0.11 I …
-
66, Pilz PSS 3075-3 Series Wiring the Inputs and Outputs 7-16 Operating Manual: PSS 3075-3 Series Alarm inputs (DIF) Example: Alarm test Features: • The test pulse must be allocated to the input in the system software’s PSS Configurator (e.g. PSS WIN-PRO). • The alarm inputs on the programmable …
-
65, Pilz PSS 3075-3 Series Operating Manual: PSS 3075-3 Series 7-15 24 V DC L+ L- X5 X6 0 V I 1.0 I 1.1 I 1.2 I 1.3 I 1.4 I 1.5 I 1.6 I 1.7 0 V I 1.8 I 1.9 I 3.0 I 3.1 I 3.2 I 3.3 I 3.4 I 3.5 X0 PSS X1/X2 24 V 0 V 24 V 0 V 24 V DC 24 V DC X7 24 V 0 V 24 V DC Please ensure safety regu…
-
77, Operating Manual: PSS 3075-3 Series 8-5 User interface (“USER”) The user interface is a combined RS 232/RS 485 interface. Both interfaces are available on a male 9-pin D-Sub connector. NOTICE Never operate the combined RS 232 and RS 485 interface simultaneously or in parallel. The programmable safety …
-
20, Overview 2-10 Operating Manual: PSS 3075-3 Series PSS SB 3075-3 DP-S Fig. 2-4: Front view of PSS SB 3075-3 DP-S RUN FS PG RUN ST POWER RUN STOP AUTO PG SPS ST FS PSS SB 3075-3 DP-S USER F-STACK 0 V I 1.8 I 1.9 I 3.0 I 3.1 I 3.2 I 3.3 I 3…
-
22, Pilz PSS 3075-3 Series Overview 2-12 Operating Manual: PSS 3075-3 Series PSS SB 3075-3 ETH-2, PSS SB 3075-3 ETH-2 SE Fig. 2-5: Front view of PSS SB 3075-3 ETH-2 RUN FS PG RUN ST POWER RUN STOP AUTO PG SPS ST FS PSS SB 3075-3 ETH-2 USER F-STACK 0 V I 1.8 I 1.9 I 3.0 I 3.1 I 3.2 …
-
51, Operating Manual: PSS 3075-3 Series 7-1 Configuration of the screw terminals and connector description Fig. 7-1: Terminal configuration on programmable systems from the PSS 3075-3 series (Example: PSS 3075-3) Wiring the Inputs and Outputs Supply voltage X8 O1.16 … O1.18: dual-pole O4.0 … O4.2: single-po…
-
2, All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz ® , PIT ® , PMI ® , PNOZ ® , Primo ® , PSEN ® , PSS ® , PVIS ® …
-
95, 11-1Operating Manual: PSS 3075-3 Series Appendix Address of Safety Network International e.V. Safety Network International e.V. Robert-Bosch-Straße 30 D-73760 Ostfildern Germany Tel. No.: +49 7 11 34 09-1 18 Fax No.: +49 7 11 34 09-4 49 E-Mail: in[email protected] Changes in the documentation Changes in V…
-
Pilz PSS 3075-3 Series User Manual
-
Pilz PSS 3075-3 Series User Guide
-
Pilz PSS 3075-3 Series PDF Manual
-
Pilz PSS 3075-3 Series Owner’s Manuals
Recommended Instructions: TWIN TRAIL, FreeSpace 360P Series II, DF-S 50
-
PTZOptics PT-JOY-G2
® Ver. 1.0 – 8.29.2017 Page1 PTZOptics IP Joystick Controller Second Generation IP Joystick Controller Installation & Operation Manual Please visit www.ptzoptics.com for the most up to date version of this manual …
PT-JOY-G2 24
-
Sony BDV-F500
Quick Setup GuideGuía de ajuste rápido4-184-719-11(1)BDV-F500©2010 Sony Corporation Printed in Malaysia1 Connect the speakers/ Conexión de los altavoces1. Connect the speaker cords to the subwoofer. Conecte los cables de altavoz al altavoz potenciador de graves.Bottom of the subwoofer/Base del altavoz potenciador de gravesColor tube (purple)/Tubo de color (púrpura)2. Thread t …
BDV-F500 1
-
Aeware In.k200
The Quick Reference Card provides a quick overview of your spa’s main functions and the operations accessible with your digital control pad.Key 1 Press Key 1 key to turn Pump 1 on at low speed. Press a second time to turn pump to high speed (with a dual-speed pump). A third time turns pump off.A built-in timer automatically turns pump off after a prede-termined period of time, unless pu …
In.k200 4
Additional Information:
Popular Right Now:
Operating Impressions, Questions and Answers:
- Manuals
- Brands
- Pilz Manuals
- Controller
- PSS 3075-3 Series
Manuals and User Guides for Pilz PSS 3075-3 Series. We have 1 Pilz PSS 3075-3 Series manual available for free PDF download: Manual
Modular Block System: Emergency Stop Circuits
6-25
The acknowledgements
FbL1 and FbL2 are also monitored in the static
condition. If there are discrepancies between the set and true condition, an
error message will be issued (
ENBL = 0) and the contactors will be
switched off immediately (
K1 = 0 and K2 = 0). The error will need to be
reset.
It is possible to reset errors via the input parameter
RSET both when ON =
0 and when
ON = 1. However, a prerequisite for setting the enable and,
when
ON = 1, switching on the contactors, is that the signals from the
feedback loops are correct.
Error messages
Any fault that is detected will be stored in the corresponding error data
word (
SSNR) of the administration data block (1st data block), until the
fault has been fully dealt with.
• Error messages in the administration data block
— Bit 00:
Fault as the signal changes at input parameter
ON,
feedback loop 1 (
FbL1) remains open
Remedy: Check contactor, contacts, cable, input card, output
card, value of input parameter
TFbL and all conditions and
then reset (input parameter
RSET)
— Bit 01:
Fault as the signal changes at input parameter
ON,
feedback loop 1 (
FbL1) remains closed
Remedy: Check contactor, contacts, cable, input card, output
card, value of input parameter
TFbL and all conditions and
then reset (input parameter
RSET)
— Bit 02:
Fault as the signal changes at input parameter
ON,
feedback loop 2 (
FbL2) remains open
Remedy: Check contactor, contacts, cable, input card, output
card, value of input parameter
TFbL and all conditions and
then reset (input parameter
RSET)
Table of Contents for Pilz PSS 3075-3 Series:
-
Supply Voltage 6-2 Operating Manual: PSS 3075-3 Series • The external power supply for the programmable safety system should be connected as shown in Fig. 6-1. Fig. 6-1: Supplying programmable safety systems from the PSS 3075-3 series • The external power supply for the outputs on the programmable safety system should be connected as shown in Fig. 6-2. Fig. 6-2: Supplying the outputs on programmable safety systems from the PSS 3075-3 se
-
11-3Operating Manual: PSS 3075-3 Series Changes in Version 21 071-10 Old page — New page — Change Additional PSS 3075-3 NR, expanded in various places
-
Operating Manual: PSS 3075-3 Series 6-1 General requirements Please note the following: • When selecting the power supply, please refer to the requirements stated under “Technical Details”. INFORMATION The output circuits have been designed to guarantee maximum safety. To achieve this, extensive tests are carried out internally. If the supply voltage is interrupted briefly during a test function, the relevant test puls
-
Interfaces 8-2 Operating Manual: PSS 3075-3 Series Programming device interface (“PG”) The programming device interface is a combined RS 232/RS 485 interface. Both interfaces are available on a male 9-pin D-Sub connector. The interface enables communication between the programming device and the PSS. The termination can be activated via links within the connector (see Fig. 8-3 in the section entitled “RS 485 programming device interface”). NOTICE Never operate the combined RS 232 and RS 485 interface simultaneously or in parallel. T
-
Safety 3-4 Operating Manual: PSS 3075-3 Series Use of qualified personnel The safety system may only be assembled, installed, programmed, commissioned, operated, maintained and decomissioned by qualified personnel. Qualified personnel are people who, because they are: • Qualified electrical engineers and • Have received training from qualified electrical engineers, are suitably experienced to operate devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology. EMCD The safety system is designed for us
-
1-3Operating Manual: PSS 3075-3 Series Overview of documentation 1 Introduction The introduction is designed to familiarise you with the contents, structure and specific order of this manual. 2 Overview This chapter provides information on the most important features of the programmable safety systems. 3 Safety This chapter must be read as it contains important information on safety regulations and intended use. 4 Function Description This chapter describes the
-
Operating Manual: PSS 3075-3 Series 9-5 O -1.19 O +1.19 O -1.20 O +1.20 O — 1.21 O +1.21 O 4.8 O 4.9 O 4.10 1 · X7 · 3 1 · · · X8 · · · 9 1 · · · X9 · · · 9 1 · · · X10 · · · 9 1 · · · X11 · · · 9 X8/X9 PWR PWR RUN FS PG RUN ST POWER RUN STOP AUTO PG SPS ST FS PSS 3075-3 1 · X0 · 4 USER F-STACK 0 V I 0.8 I 0.9 I 0.10 I 0.11 I 0.12 I 0.13 I 0.14 I 0.15 0 V I 0.0
-
Operating Manual: PSS 3075-3 Series 7-9 X1 X2 X3 X4 0 V I 0.8 I 0.9 I 0.10 I 0.11 I 0.12 I 0.13 I 0.14 I 0.15 0 V I 0.0 I 0.1 I 0.2 I 0.3 I 0.4 I 0.5 I 0.6 I 0.7 O -2.17 O +2.17 O 2.15 O/T 2.0 O/T 2.1 O/T 2.2 O/T 2.3 O -2.18 O +2.18 O -2.16 O +2.16 O 2.8 O 2.9 O 2.10 O 2.11 O 2.12 O 2.13 O 2.14 OSSD1 OSSD2 24 V 0 V 24 V DC L+ L- X0 PSS X
-
Technical Details 10-2 Operating Manual: PSS 3075-3 Series Connection type CPU Processing time Real-time clock Alarm processing Flags Failsafe section Standard section Times Time base Counters Data memory Failsafe section Standard section Program memory Failsafe section Standard section Display Interfaces Battery (not on PSS 3075-3 NR) Service life SafetyBUS p Status display Transmission rate Cable runs Transmission type Connection Plug-in screw connectors or spring-loaded terminals (accessories) Typ. 0.
-
Interfaces 8-4 Operating Manual: PSS 3075-3 Series Programming device interface RS 485 If you need to cover longer distances between the programming device and PSS (from approx. 15 m), use the RS 485 interface on the PSS. If the programming device has no RS 485 interface, connect the RS 485 interface on the PSS to the RS 232 interface on the programming device via the C-PC-PAP-2 interface adapter (order no. 305 155). To connect the PSS to the programming device or to t
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of Pilz PSS 3075-3 Series device using right now.
(Ocr-Read Summary of Contents of some pages of the Pilz PSS 3075-3 Series Document (Main Content), UPD: 25 April 2023)
-
56, Wiring the Inputs and Outputs 7-6 Operating Manual: PSS 3075-3 Series Example: Single-channel, failsafe input device, without test pulse Features: • Depending on the application area and its respective regulations, this connection diagram is suitable for input devices with frequent and infrequent operation in accordance with EN 954-1, up to category 2. The possibility of a short circuit occurring in the ext…
-
93, 10-7Operating Manual: PSS 3075-3 Series The names of products, goods and technologies used in this manual are trademarks of the respective companies. Accessories Battery PSS ZKL 3075-3 (Set of plug-in screw connectors) PSS ZKF 3075-3 (Set of sprint-loaded terminals) PSS ZCM Cable Mounting Plate (Mounting plate for cable strain relief) PSS ZCC Cable Clip (Cable feed retainer) PSS ZKL Upgrade Kit 3046/3074 (Plug-in screw connector to upgrade the supply voltage terminal on a PSS 3046…
-
39, Operating Manual: PSS 3075-3 Series 4-7 Dual-pole outputs (DOZ) 9 dual-pole outputs are available. The load must be connected between the “+” and “-” terminals. When the CPU sends a “1” signal via the system bus, the PSS supplies 24 VDC to the relevant output. The status of the outputs is displayed through LEDs, which light as soon as a “1” signal (24 VDC) is present at the output. Internal diagnostic circuitry tests the function of the connected outputs. On outputs that are swit…
-
38, Function Description 4-6 Operating Manual: PSS 3075-3 Series Block SB255 DB003 DB001 Input FUNK = 2 DW200 DW201 DW202 Output ERG = 1 DW200 Key Deactivate output power-up test in bits Function performed without error Incorrect SB255 calls will lead to a STOP condition Slot number on the PSS 3075-3 series: 2 / 4 Masks for outputs 2.00 … 2.15 / 4.00 … 4.15 If this is set on a bit belonging to an output, the power-up test for this output will be deactivated. For example: 0101…
-
3, 1Operating Manual: PSS 3075-3 Series Introduction 1-1 Validity of documentation 1-2 Overview of documentation 1-3 Definition of symbols 1-4 Overview 2-1 Front views 2-4 PSS 3075-3, PSS 3075-3 NR 2-4 PSS 3075-3 DP-S 2-6 PSS SB 3075-3 2-8 PSS SB 3075-3 DP-S 2-10 PSS SB 3075-3 ETH-2, PSS SB 3075-3 ETH-2 SE 2-12 PSS SB 3075-3 CANopen 2-14 PSS SB 3075-3 ETH-2 CANopen 2-16 Safety 3-1 Intended use 3-1 Product modifications 3-2 Categories in accordance with EN 954-1 …
-
20, Overview 2-10 Operating Manual: PSS 3075-3 Series PSS SB 3075-3 DP-S Fig. 2-4: Front view of PSS SB 3075-3 DP-S RUN FS PG RUN ST POWER RUN STOP AUTO PG SPS ST FS PSS SB 3075-3 DP-S USER F-STACK 0 V I 1.8 I 1.9 I 3.0 I 3.1 I 3.2 I 3.3 I 3.4 I 3.5 0 V I 1.0 I 1.1 I 1.2 I 1.3 I 1.4 I 1.5 I 1.6 I 1.7 1 · · · X5 · · · 9 1 · · · X6 · · ·…
-
90, Technical Details 10-4 Operating Manual: PSS 3075-3 Series Outputs — dual-pole Number of outputs Output current at “1” Short circuit protection Limitation of inductive switch-off Residual current at “0” Signal Signal level at “0” Signal level at “1” Output switch delay Test pulse Environmental data Protection type (EN 60529, 02/00) Mounting position Ambient temperature (EN 60068-2-14, 11/…
-
91, 10-5Operating Manual: PSS 3075-3 Series Mechanical data Weight PSS 3075-3, PSS 3075-3 NR PSS 3075-3 DP-S PSS SB 3075-3 PSS SB 3075-3 ETH-2 (SE) PSS SB 3075-3 DP-S PSS SB 3075-3 CANopen PSS SB 3075-3 ETH-2 CANopen Dimensions (H x W x D) PSS 3075-3, PSS 3075-3 NR PSS 3075-3 DP-S, PSS SB 3075-3, PSS SB 3075-3 ETH-2 (SE) PSS SB 3075-3 DP-S, PSS SB 3075-3 CANopen, PSS SB 3075-3 ETH-2 CANopen 2300 g 2700 g 2750 g 2850 g 305…
-
36, Function Description 4-4 Operating Manual: PSS 3075-3 Series Once the CPU sends a “1” signal via the system bus, the PSS will supply 24 VDC to the relevant output. The status of the outputs is displayed through LEDs, which light as soon as a “1” signal (24 VDC) is present at the output. Internal diagnostic circuitry tests the function of the outputs. During each cycle, the CPU compares the actual status of the outputs with the process image of t…
-
44, Pilz PSS 3075-3 Series Installation 5-4 Operating Manual: PSS 3075-3 Series Fig. 5-3: Installation options for the programmable safety system PSS SB 3075-3 DP-S, PSS SB 3075-3 CANopen and PSS SB 3075-3 ETH-2 CANopen Dimensions stated in mm («) Installing the safety system PSS SB 3075-3 DP-S, PSS SB 3075-3 CANopen and PSS SB 3075-3 ETH-2 CANopen Dimensions in mm («) excluding interfaces and operating controls : H x W x D: 246.4 x 196.8 x 162 (9.70″ x 7.58» x 6.…
-
97, 11-3Operating Manual: PSS 3075-3 Series Changes in Version 21 071-10 Old page — New page — Change Additional PSS 3075-3 NR, expanded in various places
… -
92, Technical Details 10-6 Operating Manual: PSS 3075-3 Series Derating diagrams Current load capacity of the outputs, depending on the ambient temperature T u I [A] T u [°C] 3,5 40 55 3,0 1,0 6045 50 2,0 Max. current load capacity of 3.5 A when T u >45 °C Continuous duty: 60% based on T max : 40 s I [A] t on [s] 3,5 24 40 T max
… -
84, Operation and Maintenance 9-4 Operating Manual: PSS 3075-3 Series Fig. 9-1: Changing the battery, part 1 (example: PSS 3075-3) CAUTION! Adverse effect on the safety functions! Please ensure that no metal parts get into the open PSS system, as this could adversely affect the system’s safety functions. Please proceed with care! Switch off the supply voltage, remove connector and terminal blocks. Remove the cap from the “F-STACK” button. O -1.19 O +1.19 O -1.20 O +1.20 O — 1.21 O +1.…
-
14, Overview 2-4 Operating Manual: PSS 3075-3 Series Front views PSS 3075-3, PSS 3075-3 NR Fig. 2-1: Front view of PSS 3075-3 O -1.19 O +1.19 O -1.20 O +1.20 O — 1.21 O +1.21 O 4.8 O 4.9 O 4.10 1 · X7 · 3 1 · · · X8 · · · 9 1 · · · X9 · · · 9 1 · · · X10 · · · 9 1 · · · X11 · · · 9 X8/X9 PWR PWR RUN FS PG RUN ST POWER RUN STOP AUTO PG SPS ST FS PSS 3075-3 1 · X0 · 4 USER F-STACK 0 V I 0.8 I 0.9 I 0.10 I 0.11 I 0.12 …
-
55, Operating Manual: PSS 3075-3 Series 7-5 X1 X2 X3 X4 0 V I 0.8 I 0.9 I 0.10 I 0.11 I 0.12 I 0.13 I 0.14 I 0.15 0 V I 0.0 I 0.1 I 0.2 I 0.3 I 0.4 I 0.5 I 0.6 I 0.7 O -2.17 O +2.17 O 2.15 O/T 2.0 O/T 2.1 O/T 2.2 O/T 2.3 O -2.18 O +2.18 O -2.16 O +2.16 O 2.8 O 2.9 O 2.10 O 2.11 O 2.12 O 2.13 O 2.14 X5 X6 0 V I 1.0 I 1.1 I 1.2 I 1.3 I 1.4 I 1.5 I 1.6 I 1.7 0 V I 1.8 I 1.9 I 3.…
Увеличить |
|
Задайте вопрос по этому товару | |
Контроллер безопасности Pilz PSS SB 3075-3. Заказной код 300240.
|
|
|
|
Мнения покупателей:Еще нет мнений об этом товаре. |
|