Have you read the Tutorials?
Yes
Have you read the FAQ and checked for duplicate open issues?
Yes, no corresponding errors with this 3016 root cause
What version of Shaka Player are you using?
2.5.10
Please ask your question
I try to understand this error that appears exclusively when running Shaka on Tizen TV:
onshakaError : {«severity»:2,»category»:3,»code»:3016,»data»:[3,null,»: Buffers did not monotonically increase.»]}
The conditions are:
- 3 streams in DASH manifest : 1) 1920×1080/6,4Mbps/50fps, 2) 1440×1080/4,5Mbps/25fps, 3) 1280×720/3Mbps/25fps.
- When the available bandwidth decrease quickly from 12 Mbps to 5 Mbps for example, Shaka selects the 720p profil and the error is triggered.
- When I suppress the 720p stream from available streams, the problem doesn’t appear (but I often have buffering instead).
Can you please explain me what does mean exactly this error? Could it be something managable by Shaka by configuring differently «buffers» or could it be directly linked to the Tizen Tv capacities?
Thanks in advance for your help!
3016 is VIDEO_ERROR, which is just a forwarded error from the browser. That error string, is copied from what the browser gives us; so we don’t have any control or knowledge of what this means. Based on the message and your behavior, there are two possibilities:
First, your 720p stream has frames that are out of order. If you play that stream by itself, does it work?
Secondly, the browser is choking when we switch streams because we are appending a segment that has some frames that are already buffered. If your streams aren’t aligned, we’ll need to append a segment that overlaps some already buffered content. We’ve seen other browsers have problems with this before. So we highly suggest your streams be aligned. This means that each segment covers the same time from each stream. For example: each stream has segments 0-10, 10-20, etc. If you have a stream with 0-8,8-18,18-28, you may have problems.
If you could send us some example content that reproduces this, we may be able to provide more info. You can send it privately to shaka-player-issues@google.com if you want.
Thanks for the answer.
The 720p stream alone works, and even some transitions are ok, so if your hypothesis is correct, that mean it’s localized temporaly.
But when we configure all streams to be 50 fps, the problem disapears completely. So according to what you said, maybe a rounding timestamp problem…
I’ll see if I can share a stream with you, but as the problem is random, and requires very bad access network conditions to be reproduced, I don’t want you to waste your time.
Were you able to get a sharable stream? Is this still an issue for you? You could also try manually switching streams with player.selectVariantTrack
; the second argument is a boolean for whether to clear the buffer. Passing false
will simulate ABR by not clearing the buffer, but passing true
will clear the buffer and maybe make the error go away.
Hi @TheModMaker . We found a problem in our streams, the «tftd» value is not aligned between different profiles and so buffer recoveries appear. We are trying to correct it, but your note could be used as long as the problem exists, if in native ABR behaviour we can force the flush of the buffer, as you said when you make manually the selectvariantTrack(). Is it so configurable?
Sorry for the delay. I don’t think it’s a good idea to have a setting for that. ABR is meant to be smooth, and clearing the buffer would guarantee the video stop (or at least stutter). If you really need this, I think you could create a new AbrManager class and forward the call to our version and change the arguments. The callback given to AbrManager allows clearing the buffer, so you could do it in your version.
Since this seems to be a stream or platform bug, I’m going to close.
Pervasive Documentation This status code typically indicates a corrupt file, an error while reading from or writing to the disk. The file is damaged, and you must recover it. Refer to the Advanced Operations Guide for more information on recovering files.
How do I manually start Pervasive SQL?
Point to Settings, and click Control Panel. Double-click Administrative Tools. Double-click Services….
- From the Windows desktop, click Start.
- In the right pane, click Pervasive PSQL Client Engine.
- On the Action menu, click Stop.
- On the Action menu, click Restart.
What is pervasive database?
Pervasive Software was a company that developed software including database management systems and extract, transform and load tools. Pervasive Data Integrator and Pervasive Data Profiler are integration products, and the Pervasive PSQL relational database management system is its primary data storage product.
How do I connect to a Pervasive database in SQL?
Connecting to Pervasive via ODBC Once the ODBC driver is installed and an ODBC datasource is configured, open the connection wizard, select Pervasive as the database type, ODBC as the connection type, and select the name of the ODBC datasource you configured to make an ODBC connection to Pervasive.
How do you stop or start the pervasive actian service?
If using Sage 50 2020 or newer, the name of the service has been changed from Pervasive to Actian, as noted below.
- Press Windows+R keys.
- Type SERVICES.MSC, and then click OK.
- (Quantum users only) Right-click Sage 50 SmartPosting 20xx, and then select Stop.
- Right-click Actian PSQL Workgroup Engine, and then select Stop.
How do I stop and start the pervasive actian services on a server or workstation?
Click on Start, type services. msc in the search field, and hit Enter. Locate the Pervasive/Actian service, click once on the service(s) to highlight them, right-click and choose Stop.
What is pervasive data intelligence?
Pervasive data intelligence is not providing access to raw data, but to include everyone in the formation and attainment of business objectives.
What is pervasive service?
1. A delocalized and persistent ICT service that allows its users to access the functionalities it offers at any time or place.
How do I install Pervasive ODBC driver?
From the Windows taskbar, click Start and then select Programs, Administrative Tools, Data Sources (ODBC). Click the System DSN tab and then click Add. Select Pervasive ODBC Engine Interface and then click Finish.
How do I run a pervasive service?
For Sage 50 2019 and older, look for Pervasive PSQL Workgroup Engine, instead….
- Press the WINDOWS KEY + R to open a Run prompt.
- Type Services.
- Locate and right-click the Actian PSQL Workgroup Engine entry in the list and select Properties.
- Change the Startup type selection to Automatic (delayed).
- Select the Recovery tab.
How do I restart pervasive actian and Sage services to unlock files?
At the server, log on as the administrator….
- Click Start, All Programs, Pervasive PSQL, Engines, Stop Engine.
- Click Start, All Programs, Pervasive PSQL, Engines, Start Engine.
- Start and click on the “Start Search” box.
- Type services. msc, and then click OK.
- Locate Sage Service Host, right click and select Restart.
How do you stop or start the pervasive service in Sage 50?
What does Btrieve status 161 mean on Pervasive PSQL?
Most of these problems will result in a Btrieve Status 161 being returned to the application, which is simply a generic “License Exceeded” message. Troubleshooting this status code can sometimes be difficult, especially if you are unfamiliar with the PSQL tools and utilities.
What is error code 3016 for pervasive engine?
Error Code 3016. Cause: Improperly configured network and/or users. The Pervasive Engine has not started automatically, or has been prevented from starting.
When does Pervasive.SQL return a non-zero status code?
When the Pervasive.SQL database engine needs to report an issue it returns a non-zero status code to the application (Omega, WIPC, etc.). Errors related to a database operation being attempted by this application usually fall within the 1 – 199 value range allocated to Btrieve API calls.
How to change directory status in Pervasive Control Center?
Click Change under Directory Status, click the button with three dots (…) then navigate to the computer name of your server and select it. You must make this change on every system on the network, then reboot each computer. Open the Pervasive Control Center > Configure Microkernel Router > Application characteristics.
Is the category for this document correct?
- Engineering & Technology
- Computer Science
- Databases
Thank you for your participation!
No more boring flashcards learning!
Learn languages, math, history, economics, chemistry and more with free Studylib Extension!
- Distribute all flashcards reviewing into small sessions
- Get inspired with a daily photo
- Import sets from Anki, Quizlet, etc
- Add Active Recall to your learning and get higher grades!
Add to Chrome
It’s free
Номер ошибки: | Ошибка 3016 | |
Название ошибки: | Microsoft Access Error 3016 | |
Описание ошибки: | Field will not fit in record. | |
Разработчик: | Microsoft Corporation | |
Программное обеспечение: | Microsoft Access | |
Относится к: | Windows XP, Vista, 7, 8, 10, 11 |
Определение «Microsoft Access Error 3016»
«Microsoft Access Error 3016» обычно называется формой «ошибки времени выполнения». Разработчики программного обеспечения, такие как Microsoft Corporation, обычно принимают Microsoft Access через несколько уровней отладки, чтобы сорвать эти ошибки перед выпуском для общественности. Ошибки, такие как ошибка 3016, иногда удаляются из отчетов, оставляя проблему остается нерешенной в программном обеспечении.
Некоторые пользователи могут столкнуться с сообщением «Field will not fit in record.» при использовании Microsoft Access. В случае обнаруженной ошибки 3016 клиенты могут сообщить о наличии проблемы Microsoft Corporation по электронной почте или сообщать об ошибках. Microsoft Corporation может устранить обнаруженные проблемы, а затем загрузить измененный файл исходного кода, позволяя пользователям обновлять свою версию. Таким образом, когда ваш компьютер выполняет обновления, как это, это, как правило, чтобы исправить проблемы ошибки 3016 и другие ошибки внутри Microsoft Access.
Что генерирует ошибку времени выполнения 3016?
Сбой во время запуска Microsoft Access или во время выполнения, как правило, когда вы столкнетесь с «Microsoft Access Error 3016». Следующие три наиболее значимые причины ошибок выполнения ошибки 3016 включают в себя:
Ошибка 3016 Crash — это типичная ошибка 3016 во время выполнения, которая полностью аварийно завершает работу компьютера. Это возникает, когда Microsoft Access не работает должным образом или не знает, какой вывод будет подходящим.
Утечка памяти «Microsoft Access Error 3016» — ошибка 3016 приводит к постоянной утечке памяти Microsoft Access. Потребление памяти напрямую пропорционально загрузке ЦП. Критическими проблемами, связанными с этим, могут быть отсутствие девыделения памяти или подключение к плохому коду, такому как бесконечные циклы.
Ошибка 3016 Logic Error — Логические ошибки проявляются, когда пользователь вводит правильные данные, но устройство дает неверный результат. Это происходит, когда исходный код Microsoft Corporation вызывает уязвимость при обработке информации.
Повреждение, отсутствие или удаление файлов Microsoft Access Error 3016 может привести к ошибкам Microsoft Access. Как правило, самый лучший и простой способ устранения ошибок, связанных с файлами Microsoft Corporation, является замена файлов. Кроме того, некоторые ошибки Microsoft Access Error 3016 могут возникать по причине наличия неправильных ссылок на реестр. По этой причине для очистки недействительных записей рекомендуется выполнить сканирование реестра.
Ошибки Microsoft Access Error 3016
Наиболее распространенные ошибки Microsoft Access Error 3016, которые могут возникнуть на компьютере под управлением Windows, перечислены ниже:
- «Ошибка Microsoft Access Error 3016. «
- «Недопустимый файл Microsoft Access Error 3016. «
- «Извините, Microsoft Access Error 3016 столкнулся с проблемой. «
- «Microsoft Access Error 3016 не может быть найден. «
- «Microsoft Access Error 3016 не может быть найден. «
- «Ошибка запуска в приложении: Microsoft Access Error 3016. «
- «Не удается запустить Microsoft Access Error 3016. «
- «Microsoft Access Error 3016 выйти. «
- «Microsoft Access Error 3016: путь приложения является ошибкой. «
Обычно ошибки Microsoft Access Error 3016 с Microsoft Access возникают во время запуска или завершения работы, в то время как программы, связанные с Microsoft Access Error 3016, выполняются, или редко во время последовательности обновления ОС. Отслеживание того, когда и где возникает ошибка Microsoft Access Error 3016, является важной информацией при устранении проблемы.
Причины проблем Microsoft Access Error 3016
Большинство проблем Microsoft Access Error 3016 связаны с отсутствующим или поврежденным Microsoft Access Error 3016, вирусной инфекцией или недействительными записями реестра Windows, связанными с Microsoft Access.
Точнее, ошибки Microsoft Access Error 3016, созданные из:
- Поврежденные ключи реестра Windows, связанные с Microsoft Access Error 3016 / Microsoft Access.
- Вирус или вредоносное ПО, повреждающее Microsoft Access Error 3016.
- Вредоносное удаление (или ошибка) Microsoft Access Error 3016 другим приложением (не Microsoft Access).
- Другое приложение, конфликтующее с Microsoft Access Error 3016 или другими общими ссылками.
- Microsoft Access (Microsoft Access Error 3016) поврежден во время загрузки или установки.
Продукт Solvusoft
Загрузка
WinThruster 2023 — Проверьте свой компьютер на наличие ошибок.
Совместима с Windows 2000, XP, Vista, 7, 8, 10 и 11
Установить необязательные продукты — WinThruster (Solvusoft) | Лицензия | Политика защиты личных сведений | Условия | Удаление
У меня проблема с подключением симфонии и Pervasive Database. Когда я пытаюсь подключиться к Pervasive, я получаю сообщение об ошибке:
Откройте базу данных \symfonia\demo_fk\06config.dat. Ошибка № 3012: ошибка недокументирована
Почему я не могу подключиться?
Ошибка 3012 означает:
3012: Локальный движок недоступен для маршрутизатора MicroKernel. Доступ к локальному движку невозможен, поскольку он не загружен или не может быть запущен. Вы можете получить этот код состояния, если попытаетесь получить доступ к локальному файлу на клиенте, и у вас нет установленного механизма рабочей группы или если вы пытаетесь получить доступ к локальному файлу на сервере, а механизм сервера не запущен.
Обычно это происходит, когда программа пытается получить доступ к файлу на машине, на которой не установлен Pervasive. Убедитесь, что ваша база данных указывает на правильное расположение файлов данных.
Введите минимум 50 символов