Ошибка элемент не найден 0x800706e1

When W32Time starts to output warning  in your system logs you may often get the following message for NtpClient Error 0x800706E1: “NtpClient was unable to set a domain peer to use as a time source because of discovery error. NtpClient will try again in 3473457 minutes and double the reattempt interval thereafter. The error was: The entry is not found. (0x800706E1)”.

As the message mentions the error occurs because the W32Time service cannot find the time source it thinks it needs:

  • If it is a client computer or member server, it should be a Domain Controller of its domain
  • It it is a stand-alone computer, by default it it an external source
  • If it is a domain controller, this should be the domain controller holding the PDC Emulator role in the top domain of the forest

Firewall / Time Difference between computers

Easy thought as usual: check your firewall rules: the NTP ans SNTP protocol operate on UDP/123. One easy way to check this from a Windows computer is:

w32tm /stripchart /computer:NameOfTheOtherComputer /samples:5

This command will try to connect  to the remote computer and check the clock difference between that computer and yours.

If there is no NTP server out there, you’ll get an answer such as  error: 0x80070584

The delay (d) is the delay between computers and the offset is the time difference between the 2 computers

Checking the configuration

To check the configuration, you have two options:

  • looking at the registry under HKLM\System\CurrentControlSet\Services\W32Time; Two subkeys are often of interest: Parameters and Config
  • Use w32tm to display that configuration. This one has the advantage to let you know if the configuration was set up locally or using a Group Policy Object (GPO).  Result sample is:

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    41

    42

    43

    44

    45

    46

    47

    [Configuration]

    EventLogFlags: 2 (Local)

    AnnounceFlags: 10 (Local)

    TimeJumpAuditOffset: 28800 (Local)

    MinPollInterval: 6 (Local)

    MaxPollInterval: 10 (Local)

    MaxNegPhaseCorrection: 172800 (Local)

    MaxPosPhaseCorrection: 172800 (Local)

    MaxAllowedPhaseOffset: 300 (Local)

    FrequencyCorrectRate: 4 (Local)

    PollAdjustFactor: 5 (Local)

    LargePhaseOffset: 50000000 (Local)

    SpikeWatchPeriod: 900 (Local)

    LocalClockDispersion: 10 (Local)

    HoldPeriod: 5 (Local)

    PhaseCorrectRate: 7 (Local)

    UpdateInterval: 100 (Local)

    [TimeProviders]

    NtpClient (Local)

    DllName: C:\Windows\system32\w32time.dll (Local)

    Enabled: 1 (Local)

    InputProvider: 1 (Local)

    CrossSiteSyncFlags: 2 (Local)

    AllowNonstandardModeCombinations: 1 (Local)

    ResolvePeerBackoffMinutes: 15 (Policy)

    ResolvePeerBackoffMaxTimes: 7 (Policy)

    CompatibilityFlags: 2147483648 (Local)

    EventLogFlags: 2 (Policy)

    LargeSampleSkew: 3 (Local)

    SpecialPollInterval: 3600 (Policy)

    Type: NTP (Policy)

    NtpServer: server1.ntp.org,0x8 server2.ntp.org,0x8 (Policy)

    NtpServer (Local)

    DllName: C:\Windows\system32\w32time.dll (Local)

    Enabled: 1 (Local)

    InputProvider: 0 (Local)

    AllowNonstandardModeCombinations: 1 (Local)

    VMICTimeProvider (Local)

    DllName: C:\Windows\System32\vmictimeprovider.dll (Local)

    Enabled: 1 (Local)

    InputProvider: 1 (Local)

Common mistakes

Common configuration mistakes include

    • using a comma separated list for the NTP Server list whereas the separator is the space. The comma is used to indicate flags if any. Even Microsoft based websites have issues with that but this page is right. So typically you would have for a standalone:

      w32tm /config /syncfromflags:MANUAL /manualpeerlist:«server1.some.dom server2.some.dom» /update

      You can even update a configuration remotely by using

      w32tm /config /computer:MachineName /syncfromflags:MANUAL /manualpeerlist:«server1.some.dom server2.some.dom» /update

    • Using anything else than synchronization to domain controllers for domain-joined machines. The following command will help you reset the flag Type to NT5DS

      w32tm /config /computer:MachineName /syncfromflags:DOMHIER /update

    • Synchronizing all Domain Controllers to an external NTP Source. All Domain controllers but the PDC emulator in the top domain must also have the NT5DS type as for a domain-joined machine
    • However, you’d better not set the  current PDC regitry entry to NTP. Since your PDC emulator server may change over time, you must have a strategy to have the entry set to NTP whenever the server is holding the PDC emulator role and revert back to NT5DS when it is no longer a PDC.
      To accommodate the floating FSMO issue, the trick is to:

      • create a WMI-filter based GPO which tells you if you’re the PDC.
      • apply a GPO about the external source only when the filter matches
      • Every step is mentioned in the following article Configuring an Authoritative Time Server with Group Policy Using WMI Filtering
    • For non-PDC DC servers, you would think to create another GPO to apply the NT5DS setting. This is cumbersome and highly risky. Instead remember that a GPO reverts the setting back to its previous value when it is no longer applied. Therefore, make sure every DC has the correct setting NT5DS when it is not holding the PDC role and you’re fine (You may still have to transfer the role once for the current PDC holder to be set up correctly)

If this section doesn’t soilve your issue you have to dive into the logs

Enabling the debug log

To enable the debug log you can once again use of the two following methods:

  • registry as described in article KB 816043.
  • running the w32tm command. Contrary to other w32tm commands you cannot use the computer parameter and therefore you must run this command locally (Or use powershell remote sessions, etc.)

w32tm /debug /enable /file:C:\windows\debug\ntpdebug.log /size:10000000 /entries:0-300 /truncate

To disable the debug log, you can issue

Searching for 0x800706E1 error

Once the logs are enabled, you may run into several different cases:

  • you see LDAP connections attempts to check the nearest Domain Controller and they fail. The scenario has been described here altogether with its solution
  • another alternative is you don’t even see LDAP Requests. In this case the log loooks like

    14851 02:51:04.6778750s NetLogonGetTimeServiceParentDomain dwErr = 1355 netlogonbits = 0.

    14851 02:51:05.0841250s Retrying resolution for domain hierarchy. Retry 1 will be in 15 minutes.

    14851 02:51:05.0841250s Logging warning: NtpClient was unable to set a domain peer to use as a time source because of discovery error. NtpClient will try again in 15 minutes and double the reattempt interval thereafter. The error was: The entry is not found. (0x800706E1)

    You may then want to check the AnnounceFlags registry settings. It should be 5 on a PDC but 10 on any other machine.

  • Remove From My Forums
  • Вопрос

  • Добрый день!

    Офис с 2 контроллерами домена на WinSrv2008R2 и 250 клиентскими машинами на ОС Vista SP2 и 7 SP1. Последнее время пользователя жалуются на невозможность входа под своей учеткой сразу же после загрузки ОС. Вылетает сообщение о том, что комп не может
    найти сервера, которые обработают запрос на вход. Но если входить не сразу, а через минуту после загрузки ОС, то все нормально. Но есть и другие проблемы. Не у всех пользователей мапятся диски. Прикручивание дисков было через логон скрипт, затем поменял через
    GPP в надежде, что поможет, но не помогло. У кого-то сетевые диски есть, у кого-то их нет. Вот такие ошибки в журналах на проблемных компах:

    1. Компьютер не может установить безопасный сеанс связи с контроллером домена DOMAIN по следующей причине:

      Отсутствуют серверы, которые могли бы обработать запрос на вход в сеть.

      Это может затруднить проверку подлинности. Убедитесь, что компьютер подключен к сети. Если ошибка повторится, обратитесь к администратору домена. 

      Дополнительные сведения

      Если данный компьютер является контроллером указанного домена, он устанавливает безопасный сеанс связи с эмулятором основного контроллера этого домена. В противном случае компьютер устанавливает безопасный сеанс связи с произвольным контроллером данного
      домена.

    2. NTP-клиенту не удалось задать узел домена в качестве источника времени из-за ошибки обнаружения. NTP-клиент повторит попытку через 3473457 мин., а затем удвоит интервал между попытками. Ошибка: Элемент не найден. (0x800706E1)
    3. Разрешение имен для имени PC.domain.local истекло после отсутствия ответа от настроенных серверов DNS.
    4. Ошибка при обработке групповой политики из-за отсутствия сетевого подключения к контроллеру домена. Это может быть временным явлением. Будет
      создано сообщение об успехе после того, как компьютер удастся подключить к контроллеру домена и групповая политика будет обработана успешно. Если в течение нескольких часов это сообщение не появляется, обратитесь к системному администратору.

    Достаточно долго борюсь с этой проблемой, но хоть как-то подобраться к ее решению мне не удалось. Очень надеюсь на вашу помощь.

Ответы

  • Добрый день!

    Офис с 2 контроллерами домена на WinSrv2008R2 и 250 клиентскими машинами на ОС Vista SP2 и 7 SP1. Последнее время пользователя жалуются на невозможность входа под своей учеткой сразу же после загрузки ОС. Вылетает сообщение о том, что комп не может
    найти сервера, которые обработают запрос на вход. Но если входить не сразу, а через минуту после загрузки ОС, то все нормально.

    Не подключены ли пользователи у Вас через управляемый коммутатор, поддерживающий STP (например Cisco Catalyst)?

    Если так, то, возможно, дело в том, что сразу после загрузки трафик не проходит, т.к. порт, к которому подключен клиент, не находится в передающем состоянии из-за STP: в процессе загрузки ОС драйвер переводит адаптер в режим работы с полной скоростью (100Мб/с
    — 1Гб/с), что для коммутатора выглядит как отключение и подключение порта к сети, и по этому поводу STP ждет 50 сек, чтобы удостовериться, что к порту не подключен коммутатор.

    Лечится это отключением интервала ожидания (или вообще STP) на соответствующих портах (в частности, на Cisco Catalyst — командой spanning-tree portfast в режиме конфигурирования интерфейса).

    Все остальные проблемы в таком случае могут быть как наведенными этой проблемой (из-за невозможности применить при загрузке политики компьютера, задержек с включением репликации DFSR и т.д.), так и независимыми — это надо проверять после устранения.


    Слава России!

    • Изменено

      9 августа 2012 г. 12:44

    • Помечено в качестве ответа
      indayo
      10 августа 2012 г. 12:38

You may occasionally  see errors in your eventlogs regarding the NtpClient or Time-Service. Most of the times these errors or warnings are temporary and are automatically fixed during the next time sync.

Event ID 129 – The entry is not found. (0x800706E1)

I faced event ID 129 today during a logon session on my Surface 4 Pro with Windows 10 installed. The exact error as shown in my event viewer was:

Event ID: 129
Source: Time-Service
NtpClient was unable to set a domain peer to use as a time source because of discovery error. NtpClient will try again in 15 minutes and double the reattempt interval thereafter. The error was: The entry is not found. (0x800706E1)

As the error tells you, you should wait 15 minutes for a retry to occur. I’m not that patient, so I forced the sync:

C:\Users\ite>w32tm /resync
Sending resync command to local computer
The following error occurred: Access is denied. (0x80070005)

w32tm access denied 0x80070005

Oh, shoot, needed Administrator privileges. So again, open CMD but now “Run as Administrator”

C:\WINDOWS\system32>w32tm /resync
Sending resync command to local computer
The command completed successfully.

w32tm resync sending resync command

Better. 🙂
Now, I verified the eventlogs to be sure the error was gone.
Success events appear in the Eventlogs. Like:

Event ID 35 : The time service is now synchronizing the system time with the time source x (ntp.d|[::]:123->[x).
Event ID 37 : The time provider NtpClient is currently receiving valid time data from x (ntp.d|[::]:123->[x).
Event ID 138: NtpClient succeeds in resolving domain peer xafter a previous failure.

Bottom line of this blog post: Some error events in the event log may be caused by a temporary loss of connectivity to your network. For example during the startup of Windows 10, your NICs may not be ready in time to sync to your time server. In case of error 0x800706E1, it’s best to wait a few minutes and try again.

Windows 8.1 Enterprise Windows 8.1 Pro Windows 8.1 Windows Server 2012 R2 Datacenter Windows Server 2012 R2 Essentials Windows Server 2012 R2 Foundation Windows Server 2012 R2 Standard Windows 7 Enterprise Windows 7 Professional Windows 7 Ultimate Windows Server 2008 R2 Datacenter Windows Server 2008 R2 Enterprise Windows Server 2008 R2 Standard Еще…Меньше

Симптомы

Если имя узла сервера центра сертификации (ЦС) превышает 52 символа, при выборе имени ЦС в конфигурации отзыва Интернет протокол состояния сертификатов (OCSP) появляется следующее сообщение об ошибке:

Сертификат центра сертификации не удалось получить, элемент не найден (исключение из HRESULT: 0x80070490)

Причина

Эта проблема возникает, поскольку ЦС по полюisplayname dпоиск OCSP. В этом случае поле отображаемое имя ЦС усекается, если она превышает 52 символа. В этом случае центр сертификации объект не найден.

Решение

Для решения этой проблемы в Windows Server 2012 R2 или Windows 8.1 установки накопительного пакета обновления 2962409 или установить исправление, описанное в данной статье.

Для решения этой проблемы в Windows 7 или Windows Server 2008 R2, установите исправление, описанное в данной статье.

Сведения об обновлении

Дополнительные сведения о накопительном пакете обновления 2962409 щелкните следующий номер статьи базы знаний Майкрософт:

2962409 Windows RT 8.1, Windows 8.1 и Windows Server 2012 R2 накопительный пакет обновления: Июнь 2014 г

Сведения об исправлении

Доступно исправление от службы поддержки Майкрософт. Однако данное исправление предназначено для устранения только проблемы, описанной в этой статье. Применяйте это исправление только в тех случаях, когда наблюдается проблема, описанная в данной статье. Это исправление может проходить дополнительное тестирование. Таким образом если вы не подвержены серьезно этой проблеме, рекомендуется дождаться следующего пакета обновления, содержащего это исправление.

Если исправление доступно для скачивания, имеется раздел «Пакет исправлений доступен для скачивания» в верхней части этой статьи базы знаний. Если этот раздел не отображается, обратитесь в службу поддержки для получения исправления.

Примечание. Если наблюдаются другие проблемы или необходимо устранить неполадки, вам может понадобиться создать отдельный запрос на обслуживание. Стандартная оплата за поддержку будет взиматься только за дополнительные вопросы и проблемы, которые не соответствуют требованиям конкретного исправления. Чтобы просмотреть полный список телефонов поддержки и обслуживания клиентов корпорации Майкрософт или создать отдельный запрос на обслуживание, посетите следующий веб-сайт корпорации Майкрософт:

http://support.microsoft.com/contactus/?ws=supportПримечание. В форме «Пакет исправлений доступен для скачивания» отображаются языки, для которых доступно исправление. Если нужный язык не отображается, значит исправление для данного языка отсутствует.

Предварительные условия

Для установки этого исправления необходимо иметь Пакет обновления 1 для Windows 7 или Windows Server 2008 R2 установлен.

Необходимость перезагрузки

Не требуется перезагружать компьютер после установки данного исправления.

Сведения о замене исправлений

Это исправление не заменяет все ранее выпущенные исправления.

Английский (США) версия данного исправления устанавливает файлы с атрибутами, указанными в приведенных ниже таблицах. Дата и время для файлов указаны в формате UTC. Дата и время для файлов на локальном компьютере отображаются в местном времени с вашим текущим смещением летнего времени (DST). Кроме того, при выполнении определенных операций с файлами, даты и время могут изменяться.

Информация о файлах для Windows 7 и Windows Server 2008 R2 и примечанияВажно. Исправления для Windows Server 2008 R2 и Windows 7 включены в одни и те же пакеты. Однако исправления на странице запроса исправлений перечислены под обеими операционными системами. Чтобы запросить пакет исправления, который применяется к одной или обеим ОС, установите исправление, описанное в разделе «Windows 7/Windows Server 2008 R2» страницы. Всегда смотрите раздел «Информация в данной статье относится к следующим продуктам» статьи для определения фактических операционных систем, к которым применяется каждое исправление.

  • Файлы MANIFEST (.manifest) и MUM (.mum), устанавливаемые для каждой среды, указаны отдельно в разделе «Сведения о дополнительных файлах для Windows 7 и Windows Server 2008 R2». Файлы MUM и MANIFEST, а также связанные файлы каталога безопасности (CAT) чрезвычайно важны для поддержания состояния обновленных компонентов. Файлы каталога безопасности, для которых не перечислены атрибуты, подписаны цифровой подписью корпорации Майкрософт.

Для всех поддерживаемых 86-разрядных версий Windows 7

Имя файла

Версия файла

Размер файла

Дата

Время

Платформа

Ocsp.msc

Неприменимо

92,554

05-Nov-2010

02:14

Неприменимо

Ocspadminnative.dll

5.2.3790.1289

252,928

11-Apr-2014

02:08

x86

Для всех поддерживаемых 64-разрядных версий Windows 7 и Windows Server 2008 R2

Имя файла

Версия файла

Размер файла

Дата

Время

Платформа

Ocsp.msc

Неприменимо

92,554

05-Nov-2010

02:15

Неприменимо

Ocspadminnative.dll

5.2.3790.1289

250,368

11-Apr-2014

02:29

x64

Сведения о дополнительных файлах

Сведения о дополнительных файлах для Windows 7 и Windows Server 2008 R2

Дополнительные файлы для всех поддерживаемых 86-разрядных версий Windows 7

Имя файла

Package_1_for_kb2950080~31bf3856ad364e35~x86~~6.1.1.0.mum

Версия файла

Неприменимо

Размер файла

1,854

Дата (UTC)

11-Apr-2014

Время (UTC)

06:39

Платформа

Неприменимо

Имя файла

Package_for_kb2950080_sp1~31bf3856ad364e35~x86~~6.1.1.0.mum

Версия файла

Неприменимо

Размер файла

1,463

Дата (UTC)

11-Apr-2014

Время (UTC)

06:39

Платформа

Неприменимо

Имя файла

X86_c68cabab32d80a96d880e44a8a1dd3b1_31bf3856ad364e35_6.1.7601.22652_none_aeed24f864801530.manifest

Версия файла

Неприменимо

Размер файла

727

Дата (UTC)

11-Apr-2014

Время (UTC)

06:39

Платформа

Неприменимо

Имя файла

X86_microsoft-windows-c..ocspadminnative-dll_31bf3856ad364e35_6.1.7601.22652_none_0e44d26a8322f5b8.manifest

Версия файла

Неприменимо

Размер файла

13 000

Дата (UTC)

11-Apr-2014

Время (UTC)

02:36

Платформа

Неприменимо

Дополнительные файлы для всех поддерживаемых 64-разрядных версий Windows 7 и Windows Server 2008 R2

Имя файла

Amd64_20e14e0f81756702d2bc0f86a6235550_31bf3856ad364e35_6.1.7601.22652_none_450b5ba07e9ece08.manifest

Версия файла

Неприменимо

Размер файла

731

Дата (UTC)

11-Apr-2014

Время (UTC)

06:39

Платформа

Неприменимо

Имя файла

Amd64_microsoft-windows-c..ocspadminnative-dll_31bf3856ad364e35_6.1.7601.22652_none_6a636dee3b8066ee.manifest

Версия файла

Неприменимо

Размер файла

13,004

Дата (UTC)

11-Apr-2014

Время (UTC)

03:03

Платформа

Неприменимо

Имя файла

Package_1_for_kb2950080~31bf3856ad364e35~amd64~~6.1.1.0.mum

Версия файла

Неприменимо

Размер файла

2,070

Дата (UTC)

11-Apr-2014

Время (UTC)

06:39

Платформа

Неприменимо

Имя файла

Package_for_kb2950080_sp1~31bf3856ad364e35~amd64~~6.1.1.0.mum

Версия файла

Неприменимо

Размер файла

1,677

Дата (UTC)

11-Apr-2014

Время (UTC)

06:39

Платформа

Неприменимо

Статус

Корпорация Майкрософт подтверждает, что это проблема продуктов Майкрософт, перечисленных в разделе «Относится к».

Ссылки

Дополнительные сведения о терминологии , которую корпорация Майкрософт использует для описания обновлений программного обеспечения.

Нужна дополнительная помощь?

Нужны дополнительные параметры?

Изучите преимущества подписки, просмотрите учебные курсы, узнайте, как защитить свое устройство и т. д.

В сообществах можно задавать вопросы и отвечать на них, отправлять отзывы и консультироваться с экспертами разных профилей.


Value: -2147023135 | 0x800706E1 | 2147944161

What does it mean ?

RPC_S_ENTRY_NOT_FOUND

 

The entry is not found.

Value: 1761 | 0x06E1 | 0b0000011011100001

Where does it come from ?


FACILITY_WIN32

 

Provides a way to handle error codes from functions in the Win32 API as an HRESULT. (Error codes in 16 — bit OLE that duplicated Win32 error codes have also been changed to FACILITY_WIN32)
Value: 7 | 0x007 | 0b00000111

Понравилась статья? Поделить с друзьями:
  • Ошибка элементы родителя не обновлены nx
  • Ошибка эсуд гранта
  • Ошибка это то что нельзя исправить
  • Ошибка энкодера epson что это
  • Ошибка эсуд ваз