Ошибка could not find installable isam

I have the following code :

string excelConnectionString = @"Provider=Microsoft.Jet.OLEDB.4.0; Data Source=C:\db\suc.xls; Extended Properties=""Excel 12.0;HDR=YES;""";

// Create Connection to Excel Workbook
using (OleDbConnection connection =
             new OleDbConnection(excelConnectionString))
{
    OleDbCommand command = new OleDbCommand
            ("Select * FROM [Sheet1$]", connection);

    connection.Open();

and i get the following error :

Could not find installable ISAM.

at connection.Open() . Any ideas ?

Dyrandz Famador's user avatar

asked Nov 18, 2010 at 12:03

Alex's user avatar

1

I had the same error, but none of the suggestions above worked. In my case all I had to do was to change my connection string to this:

string connStr = "Provider=Microsoft.ACE.OLEDB.12.0;Data Source=" + FilePath + ";Extended Properties='Excel 12.0;IMEX=1;'";

Note the Single Quote around the Extended Properties attribute (‘Excel 12.0;IMEX=1;’). Once I added those single quotes the error disappeared!

answered Feb 6, 2015 at 17:08

DigiOz Multimedia's user avatar

1

There’s no 64 bit version of the Jet OLEDB drivers, so if you are running this on a 64 bit OS you might need to target x86 in your .NET application and not Any CPU:

alt text

answered Nov 18, 2010 at 12:07

Darin Dimitrov's user avatar

Darin DimitrovDarin Dimitrov

1.0m271 gold badges3288 silver badges2930 bronze badges

4

I was getting this issue trying to opening an xls file with a more recent provider.
I fixed this issue by changing my extended properties from

Extended Properties="Excel 11.0;"

to

Extended Properties="Excel 8.0;"

I guess Excel 11 expects an xlsx style file.

answered Jun 5, 2014 at 5:10

squig's user avatar

squigsquig

7557 silver badges18 bronze badges

1

use Extended properties="\excel 8.0;

Dyrandz Famador's user avatar

answered Feb 13, 2015 at 7:45

ASKA's user avatar

ASKAASKA

211 silver badge6 bronze badges

I had the same kind of problem. I was using an Excel 2010 database. But I had a xlsx file instead of xls. I solved my problem using the connection string as fallows,

Provider=Microsoft.ACE.OLEDB.12.0;Data Source=logbook.xlsx;Extended Properties=’Excel 12.0;HDR=YES;IMEX=1;’;

What I was missing are,
I used OLEDB.4.0 instead of ACE.12.0 . I tried using ACE.14.0. But it didn’t work either.
Then I missed inverted commas ( ‘ ‘ ) around Extended Properties.

Sorry if the answer is hard to read, I am uploading this in my phone.

answered Jun 19, 2020 at 5:52

Lasindu Nuwanga's user avatar

// SET A CONNECTION WITH THE EXCEL FILE.

              OleDbConnection myExcelConn = new OleDbConnection
                  ("Provider=Microsoft.ACE.OLEDB.12.0; " +
                      "Data Source=" + Server.MapPath(".") + "\\" + fileUpload1.FileName +
                      ";Extended Properties='Excel 12.0;HDR=YES'");

Putting Single quote in Extended Properties like
Extended Properties =’Excel 12.0:HDR=YES’ solved my problem.

answered Sep 29, 2020 at 12:54

Paresh Wadekar's user avatar

Проблемы

При попытке обновить данные в книге Microsoft Excel, которая ссылается на базу данных Microsoft Access, может появиться следующее сообщение об ошибке:

Не удалось найти устанавливаемый ISAM

Эта проблема возникает в том случае, если книга была ранее открыта и обновлена в более поздней версии Excel.

Причина

Если книга Excel, связанная с базой данных Access, открыта в более поздней версии Excel, параметры могут быть добавлены в строку подключения. Если более ранняя версия Excel не распознает эти параметры, она вызывает сообщение об ошибке.

Решение

Чтобы устранить эту проблему, удалите новые параметры из строки подключения. Для этого выполните следующие действия:

  1. Откройте книгу Excel.

  2. На ленте Data (данные ) нажмите кнопку Connections (соединения ).

  3. В диалоговом окне подключения к книге выберите подключение к базе данных Access и нажмите кнопку свойства.

  4. В диалоговом окне Свойства подключения откройте вкладку Определение .

  5. Удалите из строки соединения следующие параметры:

    Jet OLEDB: пропуск проверки UserInfo = ложь; Jet OLEDB: ограниченное кэширование базы данных = ложь; Jet OLEDB: обход ChoiceField проверки = ложь

  6. В диалоговом окне Свойства подключения нажмите кнопку ОК. На этом этапе данные должны быть обновлены.

  7. В диалоговом окне подключения к книге нажмите кнопку Закрыть, а затем сохраните обновленную книгу.

Дополнительная информация

Если вы обновите и сохраните книгу в более новой версии Excel, эта неполадка будет повторяться.

Нужна дополнительная помощь?

Нужны дополнительные параметры?

Изучите преимущества подписки, просмотрите учебные курсы, узнайте, как защитить свое устройство и т. д.

В сообществах можно задавать вопросы и отвечать на них, отправлять отзывы и консультироваться с экспертами разных профилей.

Symptoms

When you try to refresh data in a Microsoft Excel workbook that links to a Microsoft Access database, you may receive the following error message: 

Could not find installable ISAM


This issue occurs if the workbook was previously opened and refreshed in a newer version of Excel.

Cause

When an Excel workbook that’s linked to an Access database is opened in a later version of Excel, parameters may be added to the connection string. If the earlier version of Excel does not recognize these parameters, it triggers the error message.

Resolution

To resolve this issue, delete the new parameters from the connection string. To do this, follow these steps:

  1. Open the Excel workbook.

  2. On the Data ribbon, click the Connections button.

  3. In the Workbook Connections dialog box, select the connection to the Access database, and then click Properties.

  4. In the Connection Properties dialog box, click the Definition tab.

  5. Delete the following parameters from the connection string:

    Jet OLEDB:Bypass UserInfo Validation=False;
    Jet OLEDB:Limited DB Caching=False;
    Jet OLEDB:Bypass ChoiceField Validation=False

  6. In the Connection Properties dialog box, click OK. At this point your data should be refreshed.

  7. In the Workbook Connections dialog box, click Close, and then save the updated workbook.

More Information

If you refresh and save the workbook in a newer version of Excel, the issue will recur.

Need more help?

Want more options?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.

I have the following code :

string excelConnectionString = @"Provider=Microsoft.Jet.OLEDB.4.0; Data Source=C:\db\suc.xls; Extended Properties=""Excel 12.0;HDR=YES;""";

// Create Connection to Excel Workbook
using (OleDbConnection connection =
             new OleDbConnection(excelConnectionString))
{
    OleDbCommand command = new OleDbCommand
            ("Select * FROM [Sheet1$]", connection);

    connection.Open();

and i get the following error :

Could not find installable ISAM.

at connection.Open() . Any ideas ?

Dyrandz Famador's user avatar

asked Nov 18, 2010 at 12:03

Alex's user avatar

1

I had the same error, but none of the suggestions above worked. In my case all I had to do was to change my connection string to this:

string connStr = "Provider=Microsoft.ACE.OLEDB.12.0;Data Source=" + FilePath + ";Extended Properties='Excel 12.0;IMEX=1;'";

Note the Single Quote around the Extended Properties attribute (‘Excel 12.0;IMEX=1;’). Once I added those single quotes the error disappeared!

answered Feb 6, 2015 at 17:08

DigiOz Multimedia's user avatar

1

There’s no 64 bit version of the Jet OLEDB drivers, so if you are running this on a 64 bit OS you might need to target x86 in your .NET application and not Any CPU:

alt text

answered Nov 18, 2010 at 12:07

Darin Dimitrov's user avatar

Darin DimitrovDarin Dimitrov

1.0m271 gold badges3288 silver badges2930 bronze badges

4

I was getting this issue trying to opening an xls file with a more recent provider.
I fixed this issue by changing my extended properties from

Extended Properties="Excel 11.0;"

to

Extended Properties="Excel 8.0;"

I guess Excel 11 expects an xlsx style file.

answered Jun 5, 2014 at 5:10

squig's user avatar

squigsquig

7557 silver badges18 bronze badges

1

use Extended properties="\excel 8.0;

Dyrandz Famador's user avatar

answered Feb 13, 2015 at 7:45

ASKA's user avatar

ASKAASKA

211 silver badge6 bronze badges

I had the same kind of problem. I was using an Excel 2010 database. But I had a xlsx file instead of xls. I solved my problem using the connection string as fallows,

Provider=Microsoft.ACE.OLEDB.12.0;Data Source=logbook.xlsx;Extended Properties=’Excel 12.0;HDR=YES;IMEX=1;’;

What I was missing are,
I used OLEDB.4.0 instead of ACE.12.0 . I tried using ACE.14.0. But it didn’t work either.
Then I missed inverted commas ( ‘ ‘ ) around Extended Properties.

Sorry if the answer is hard to read, I am uploading this in my phone.

answered Jun 19, 2020 at 5:52

Lasindu Nuwanga's user avatar

// SET A CONNECTION WITH THE EXCEL FILE.

              OleDbConnection myExcelConn = new OleDbConnection
                  ("Provider=Microsoft.ACE.OLEDB.12.0; " +
                      "Data Source=" + Server.MapPath(".") + "\\" + fileUpload1.FileName +
                      ";Extended Properties='Excel 12.0;HDR=YES'");

Putting Single quote in Extended Properties like
Extended Properties =’Excel 12.0:HDR=YES’ solved my problem.

answered Sep 29, 2020 at 12:54

Paresh Wadekar's user avatar

I’ve written some VBA code in an Excel workbook to retrieve data from an Access database in the same directory on a desktop. It works fine on my machine and several other machines running Windows XP, but when we tested this on a Vista machine, we encountered the following error:

Could not find installable ISAM

I’ve done a bunch of searching online but can’t seem to find a concrete answer. The connection string seems to be fine, and, as I mentioned, it works on several machines.

Does anyone have any idea what could be causing this? My connection string is as follows:

Provider=Microsoft.Jet.OLEDB.4.0;Data Source=D:\ptdb\Program Tracking Database.mdb;

Thanks

shruti1810's user avatar

shruti1810

3,9402 gold badges16 silver badges28 bronze badges

asked Feb 4, 2009 at 16:32

cLFlaVA's user avatar

Place single quotes around the Extended Properties:

OleDbConnection oconn = 
    new OleDbConnection(
        @"Provider=Microsoft.Jet.OLEDB.4.0;Data Source=" + path + ";Extended Properties='Excel 8.0;HDR=YES;IMEX=1;';");

Try it, it really works.

Uwe Keim's user avatar

Uwe Keim

39.6k57 gold badges175 silver badges291 bronze badges

answered May 23, 2012 at 5:36

bhupendra singh's user avatar

2

Try putting single quotes around the data source:

Provider=Microsoft.Jet.OLEDB.4.0;Data Source='D:\ptdb\Program Tracking Database.mdb';

The problem tends to be white space which does have meaning to the parser.

If you had other attributes (e.g., Extended Properties), their values may also have to be enclosed in single quotes:

Provider=Microsoft.Jet.OLEDB.4.0;Data Source='D:\ptdb\Program Tracking Database.mdb'; Extended Properties='Excel 8.0;HDR=YES;IMEX=1;';

You could equally well use double quotes; however, you’ll probably have to escape them, and I find that more of a Pain In The Algorithm than using singles.

answered Feb 4, 2009 at 16:44

BIBD's user avatar

BIBDBIBD

15.1k25 gold badges85 silver badges137 bronze badges

7

Just use Jet OLEDB: in your connection string.
it solved for me.

an example is below:

"Provider=Microsoft.Jet.OLEDB.4.0;Persist Security Info=False;Data Source=E:\Database.mdb;Jet OLEDB:Database Password=b10w"

answered Apr 8, 2013 at 12:25

Rezoan's user avatar

RezoanRezoan

1,75522 silver badges51 bronze badges

I have just encountered a very similar problem.

Like you, my connection string appeared correct—and indeed, exactly the same connection string was working in other scenarios.

The problem turned out to be a lack of resources. 19 times out of 20, I would see the «Could not find installable ISAM,» but once or twice (without any code changes at all), it would yield «Out of memory» instead.

Rebooting the machine «solved» the problem (for now…?). This happened using Jet version 4.0.9505.0 on Windows XP.

answered Oct 13, 2009 at 22:12

Chris Nielsen's user avatar

Chris NielsenChris Nielsen

14.8k7 gold badges48 silver badges54 bronze badges

I used this to update a excel 12 xlsx file

        System.Data.OleDb.OleDbConnection MyConnection;
        System.Data.OleDb.OleDbCommand myCommand = new System.Data.OleDb.OleDbCommand();
        MyConnection = new System.Data.OleDb.OleDbConnection("provider=Microsoft.ACE.OLEDB.12.0;Data Source='D:\\Programming\\Spreadsheet-Current.xlsx';Extended Properties='Excel 12.0;HDR=YES;';");
        MyConnection.Open();
        myCommand.Connection = MyConnection;
        string sql = "Update [ArticlesV2$] set [ID]='Test' where [ActualPageId]=114";// 
        myCommand.CommandText = sql;
        myCommand.ExecuteNonQuery();
        MyConnection.Close();

answered Nov 25, 2015 at 21:32

MarkVL's user avatar

Use this connection string

string connectionString = @"Provider=Microsoft.ACE.OLEDB.12.0;" +
      "Data Source=" + strFileName + ";" + "Extended Properties=" + "\"" + "Excel 12.0;HDR=YES;" + "\"";

Flexo's user avatar

Flexo

87.4k22 gold badges192 silver badges273 bronze badges

answered Oct 13, 2011 at 6:09

Shahid Manzoor's user avatar

1

This problem is because the machine can’t find the the correct ISAM (indexed sequential driver method) registered that Access needs.

It’s probably because the machine doesn’t have MSACeesss installed? I would make sure you have the latest version of Jet, and if it still doesn’t work, find the file Msrd3x40.dll from one of the other machines, copy it somewhere to the Vista machine and call regsvr32 on it (in Admin mode) that should sort it out for you.

answered Feb 4, 2009 at 16:55

pezi_pink_squirrel's user avatar

1

Use the connection string below to read from an XLSX file:

string ConnectionString = «Provider=Microsoft.ACE.OLEDB.12.0;Data
Source=» + <> + «;Extended
Properties=Excel 8.0;»;

Jason's user avatar

Jason

2,5033 gold badges38 silver badges46 bronze badges

answered Nov 22, 2012 at 13:07

Raghav's user avatar

Понравилась статья? Поделить с друзьями:
  • Ошибка could not find filesystem dll to load
  • Ошибка could not open the bcd template store
  • Ошибка code atego
  • Ошибка could not find driver
  • Ошибка couldn t resolve host