When I tried to register a COM DLL,
regsvr32 rpcrt4.dll
I get the following error message:
`The module «c:\windows\system 32\»rpcrt4.dll» was loaded but the call to DllRegisterServer failed with error code 0X80070006.
How do I fix this problem? Please help.
asked Mar 24, 2011 at 1:10
1
answered Mar 24, 2011 at 1:13
Daniel A. WhiteDaniel A. White
187k47 gold badges363 silver badges445 bronze badges
2
Open the start menu and type cmd
into the search box
Hold Ctrl + Shift
and press Enter
This runs the Command Prompt in Administrator mode.
Now type regsvr32 MyComobject.dll
answered Apr 21, 2012 at 2:18
1
Use following command should work on windows 7. don’t forget to enclose the dll name with full path in double quotations.
C:\Windows\SysWOW64>regsvr32 "c:\dll.name"
andrewsi
10.8k132 gold badges35 silver badges51 bronze badges
answered Nov 18, 2011 at 9:47
When I tried to register a COM DLL,
regsvr32 rpcrt4.dll
I get the following error message:
`The module «c:\windows\system 32\»rpcrt4.dll» was loaded but the call to DllRegisterServer failed with error code 0X80070006.
How do I fix this problem? Please help.
asked Mar 24, 2011 at 1:10
1
answered Mar 24, 2011 at 1:13
Daniel A. WhiteDaniel A. White
187k47 gold badges363 silver badges445 bronze badges
2
Open the start menu and type cmd
into the search box
Hold Ctrl + Shift
and press Enter
This runs the Command Prompt in Administrator mode.
Now type regsvr32 MyComobject.dll
answered Apr 21, 2012 at 2:18
1
Use following command should work on windows 7. don’t forget to enclose the dll name with full path in double quotations.
C:\Windows\SysWOW64>regsvr32 "c:\dll.name"
andrewsi
10.8k132 gold badges35 silver badges51 bronze badges
answered Nov 18, 2011 at 9:47
Это диагноз, но не все потеряно. Такое сообщение может «выскочить» ,
например — когда программа пытается подключить внешнее оборудование,
через внешнюю «не родную» библиотеку (специальную программу)
Подключение производится один раз на выбранном компьютере !
вот в данном примере : мы хотим получить изображение товара с web — камеры
Нажимаем «ДА» и видим это !!!!
Пере запускаем и снова видим ЭТО !!!
Почему это именно с вами ??? что за невезуха ? Ничего страшного не произошло, это не Windows ваша новая в этом виновата, может MAGAZKA виновата ???
Нужно срочно написать на форуме , что MAGAZKA отстой и ничего в ней не работает.
На самом деле все проще. У программы не хватило прав на регистрацию внешней библиотеки в системе
(простыми словами сработала защита вашей системы от вторжения из вне)
и это дело можно легко исправить
Открываем папку с каталогом программы , там должен быть файл Webcamera.ocx
вот это и есть внешняя библиотека и ее нужно зарегистрировать в Windows
есть несколько способов (можете выбрать любой)
1. Способ интерактивный
(странно не многие о нем знают)
кликаем правой кнопкой мышки по файлу
и выбираем пункт меню : «Открыть с помощью…«
переключаем на «Открыть файл в Windows«
Кнопка «Выбор программы…«
Кнопка «Обзор…«
И переходим по пути : C:\Windows\System32 находим файл regsvr32.exe выделяем его из списка , кнопка «Открыть»
Если все сделали правильно. в списке «навсегда» появиться ярлычок «Сервер регистрации,(с) Microsoft«
Кликаем по этому ярлычку и получаем вот такое радостное сообщение.
оно обозначает , что все успешно зарегистрировалось и успешно будет работать.
с чем вас я и поздравляю.
но в некоторых случаях можно получить и вот такое окно
тогда переходим ко второму варианту.
2. Вариант (регистрация через командную строку)
Меню — Пуск — вводим — CMD
правой кнопкой «Запуск от имени администратора«
появиться вот такой окно «командная строка»
вводим
C:\Windows\System32\regsvr32.exe C:\Users\yu.timofeev\Desktop\НужноЗапросы\MAG\MAGAZKANS82\WebCamera.ocx
(путь к библиотеке у вас будет отличаться от данного в примере)
и нажимаем клавишу «Enter«
вот теперь точно все зарегистрировано.
Путь к библиотеке указываете в английской раскладке :
C:\1CBASE\MAG\MAGAZKANS82 — так ПРАВИЛЬНО !
D:\Помойка\Дмитрий крутяк!!!\10-08-2016\Скачено с торента\классные кряки###\Попробовать\MAGAZKANS82 — так НЕ ПРАВИЛЬНО (русские символы, пробелы, знаки препинания,цифры , спец .символы)
ВАРИАНТ 3 : Решаем проблему с ошибкой 0x80004005 в Windows 7
Вариант 4 : Устранение ошибки с кодом 0x80004005 в Windows 10
- Remove From My Forums
-
Question
-
I’ve been trying to install the trial version of Adobe Photoshop CS3 on my windows vista home premium 32bit system. I recieved the error code 2739, upon running the installer. Upon searching Adobe’s website for help with this issue I found the fix for it was.
On a 32-bit Windows Vista system:
- Choose Start > All Programs > Accessories.
- Right-click on Command Prompt, select Run As Administrator, and authenticate.
- If the prompt reads C:\Windows\System32>, proceed to Step 4. If not, type the following command exactly as it appears below, including the quotation marks, and then press Enter:
cd "%systemroot%\System32"
- At the prompt, type
regsvr32 jscript.dll
and press Enter. - When a dialog box with the message «DllRegisterServer in jscript.dll succeeded» appears, click OK.
However, upon pressing enter after the 4rth step, i get
RegSvr32 error : The module «jscript.dll» was loaded but the call to DllRegisterServer failed with error code 0x80004005. For more infromation about this problem, search online using the error code as a search term.
After searching through, what appears to be several pages of issues, all resulting from this error code. I stumbled on this and am hoping SOMEONE can help me. I would greatly appreciate it, since my computer manufacturer tells me to contact Adobe, and Adobe tells me to contact Microsoft. I hope here I wont be directed to contact someone else for more of a run around.
Answers
-
Hi,
try the following steps:
- Run command prompt as Administrator
- Change folder by issuing the following command :
For Windows Vista 32-bit: cd C:\windows\System32
For Windows Vista 64-bit: cd C:\windows\SysWow64 - Type the following command and hit Enter:
regsvr32 jscript.dll
- Type the following command and hit Enter:
regsvr32 vbscript.dll
- Run the installer again.
and good luck!
Делюсь наблюдениями и личным опытом в области программирования и интернет-маркетинга
Ошибка 0x80004005 в Windows Vista/7 при выполнении regsvr32
Posted on | January 28, 2011 | 1 Comment
Консольная утилита regsvr32 (Microsoft© Register Server) предназначена для регистрации и отмены регистрации элементов управления OLE в реестре. Если вкратце, то сначала загружается модуль и в нем запускается функция DLLSelfRegister(), в коде которой уже вызывается функция DllRegisterServer().
Рассмотрим случай, когда при регистрации через regsvr32.exe корректного *.dll или *.ocx модуля, совместимого с вашей версией Windows (x86 или x64) возникает ошибка 0x80004005. При этом в диалоговом окне ошибки указано нечто такое:
“The module “%1″ was loaded but the call to DllRegisterServer failed with error code 0x80004005. For more information about this problem, search online using the error code as a search term”.
Для устранения ошибки нужно разобраться с User Account Control (UAC). В Windows Vista и Windows 7 действия пользователей, даже имей они права администратора, проверяются этим пресловутым UAC, который и не позволяет нам запустить программу под администратором.
Решить проблему можно или отключив User Account Control: в Панели управления -> Учетные записи пользователей -> Включение или отключение контроля учетных записей. Но лучше этого не делать, т.к. это существенно понижает защиту вашей системы от вредоносных программ.
Более простой вариант – запустить консоль cmd.exe от Администратора, кликнув по её ярлыку правой кнопкой.