Ошибка 798 не удалось найти сертификат

I am creating a VPN in Azure, and created self-signed certificate in the following places:

Local Computer:
Personal/Certificates: Issued To: FQDN name is the certificate’s name
Trusted Root Certification Authorities/Certificates:
manually copied from Personal

I have configured the VPN in Azure and it is downloaded and extracted and the vpn client is installed successfully, however, when I run the client I received the following error:

A certificate could not be found that can be used with this Extensible
Authentication Protocol. (Error 798)

Screenshot:

enter image description here

The error seems suggesting the certificate is NOT found, does the name matter?

enter image description here

Should I change the cert’s name from Azurecert to FQDN which is the name in my local computer?

Thank you for your help in advance.

UPDATE:
I removed the existing certification in Azure’s configuration and re-added back with the same FQDN name shown in local computer’s certificates, I redownloaded the client, I removed the existing installed vpn client and re-installed the new one, I receive the same error message. So it seems name is not the root cause?

UPDATE2:

The procedure I’ve followed:

  1. Create Self Signed Certificate with the FQDN name on local laptop;

    New-SelfSignedCertificate –DnsName NV-RXIE.novantas.pri -CertStoreLocation “cert:\LocalMachine\My”

  2. Add the self-signed certificate as a trusted certificate authority, Copy the new cert to Trusted Root Certificate Authorities

  3. export the cert and open it, copy the cert part and paste into the
    VPN setting – Root certificates, Public Certificate Data

  4. Download the VPN client and install it on laptop, run it

  5. Connect, failed with:

A certificate could not be found that can be used with this Extensible
Authentication Protocol. (Error 798)

Поддержка Windows Vista без установленных пакетов обновления завершилась 13 апреля 2010 года. Чтобы продолжить получать обновления для системы безопасности для Windows, убедитесь, что вы используете Windows Vista с пакетом обновления 2 (SP2). Для получения дополнительных сведений можно перейти на эту веб-страницу Майкрософт: Окончание поддержки для некоторых версий Windows

ВВЕДЕНИЕ

В этой статье перечислены коды ошибок, которое может появиться при попытке создать подключение удаленного доступа или VPN-подключения на компьютере под управлением Microsoft Windows Vista.

Дополнительная информация

В следующем списке перечислены коды ошибок, которое может появиться при попытке установить подключение удаленного доступа или операцию соединения: 600An VPN является дескриптор порта pending.601The invalid.602The порт уже open.603Caller в буфер является слишком small.604Wrong порт specified.606The информация не connected.608The устройство не exist.609The тип устройства не exist.610The буфер не invalid.612The указан недопустимый порт allocated.615The не found.616An асинхронный запрос находится в pending.617The порт или устройство выполняет уже disconnecting.618The порт не является портом open.619The является disconnected.621Cannot открыть загрузки телефонной книги file.622Cannot file.623Cannot телефонной книги найти запись телефонной книги entry.624Cannot file.625Invalid данные телефонной книги, находящиеся в телефон найти Book.627Cannot key.628The порт был disconnected.629The порт был отключен с помощью удаленного machine.630The порт был отключен из-за аппаратного failure.631The порт был отключен размер структуры user.632The incorrect.633The порт уже используется используется или не настроен для удаленного подключения к сети.Примечание. В этом сообщении слово «исходящее» содержится слова «исходящего подключения.» Превышено время неверное устройство подключено к запросу port.638The error.636The 635Unknown out.645Internal error.646The проверки подлинности учетных записей не разрешается вход в это время day.647The учетная запись имеет disabled.648The пароль учетной записи expired.649The does Нет доступа для удаленного permission.651Your модем (или другое устройство связи) сообщил ответа на error.652Unrecognized из макроса device.653A, необходимых для данного устройства не найден в устройство. INF файл section.654A команда или отклик в устройство. INF устройства ссылается на неопределенный macro655The макрос < сообщения > не найден в устройство. Макрос < defaultoff > section.656The файл INF в устройстве. «INF» содержит неопределенный macro657The устройства. INF-файл не может быть opened.658The имя устройства в устройство. INF устройства или файле. INI-файла является слишком long.659The носителей. INI-файл ссылается на неизвестное устройство name.660The. INF-файл не содержит ответов для устройства command.661The. INF-файл отсутствует command.662Attempted к макросу, не указанный в файле. INF файл section.663The носитель. INI содержит ссылку на неизвестный type.664Cannot устройства распределения memory.665The порт не настроен для удаленного Access.666Your модем (или другое коммуникационное устройство) не functioning.667Cannot чтения INI-файла носителя. INI file.668The подключения dropped.669The использование параметра в INI-файла носителя. INI-файл является invalid.670Cannot прочесть имя секции из INI-файла. INI file.671Cannot прочесть тип устройства из INI-файла. INI file.672Cannot прочесть имя устройства из INI-файла. INI file.673Cannot прочесть использование из INI-файла носителя. INI file.676The телефонной линии является ответил вместо modem.678There человек busy.677A не answer.679Cannot обнаружения carrier.680There был не запрещен, поскольку имя пользователя или пароль являются недопустимыми для domain.692Hardware сбой в порт tone.691Access звонков или УЖЕ присоединен не ДВОИЧНЫХ MACRO694ERROR DCB не КОНЕЧНЫЕ АВТОМАТЫ не FOUND695ERROR состояние МАШИНЫ STARTED696ERROR device.693ERROR STARTED697ERROR ЧАСТИЧНЫЙ ОТВЕТ LOOPING698A параметра отклика в устройство. INF-файл не в ответе устройства ожидаемого format.699The возникает буфера overflow.700The развернут команда в INF. INF-файл является слишком long.701The устройство перешло на скорость не поддерживается получен ответ driver.702Device COM indication.708The диагностики ИНТЕРАКТИВНЫХ MODE704ERROR ПЛОХОЙ обратного ВЫЗОВА NUMBER705ERROR НЕДОПУСТИМЫЙ AUTH STATE707X.25 expected.703ERROR у expired.709Error Смена пароля учетной записи на domain.710Serial были обнаружены ошибки переполнения при обмене данными с вашей modem.711RasMan Сбой инициализации. Проверьте событие log.713No линий ISDN, доступных unusable.717No IP-адресов в статическом пуле IP удаленного доступа addresses.718PPP timeout.720No PPP протоколы управления configured.721Remote PPP является конфигурация IP удаленного доступа available.716The сторона не пакет PPP responding.722The равно invalid.723The телефонный номер, включая префикс и суффикс, слишком протокола IPX long.726The не может использоваться для выполнения исходящих звонков на более чем один порт в time.728Cannot найти IP-адаптер, который не может быть привязан к удаленному Access.729SLIP используется, если не установлен протокол IP. Регистрация 730Computer не complete.731The протокола не является согласование PPP configured.732The не converging.733The протокол управления PPP для данного сетевого протокола недоступен на server.734The протокол управления связью PPP завершен. Запрошенный адрес был отвергнут 735The прервано удаленным компьютером server.736The сервер управления protocol.737Loopback detected.738The не назначил address.739The удаленный сервер не может использовать устройства TAPI password.740The шифрования Windows NT настроен для удаленного доступа не удалось инициализировать или не установлена correctly.741The локальный компьютер не поддерживает удаленный сервер encryption.742The может не поддержка encryption.749ERROR_BAD_PHONE_NUMBER752A синтаксическая ошибка во время Обработка script.753The подключение не может быть разорвано, поскольку он был создан с помощью нескольких протоколов router.754The система не может найти многоканальное подключение bundle.755The система не может выполнить автоматический дозвон, поскольку это подключение имеет специального номеронабирателя подключение specified.756This уже dialed.757Remote, службы Access не может быть запущен автоматически. Дополнительную информацию можно найти в том случае, если установлено устройство чтения смарт-карт log.764No. Не удается разрешить общий доступ к подключению к 765Internet. Подключение по локальной сети уже настроен IP-адрес, необходимый для автоматической IP-адресации. Не удалось найти сертификат 766A. Подключения, которые используют этот протокол L2TP через IPSec, требуется установка компьютере сертификата компьютера. Не удается разрешить общий доступ к подключению к 767Internet. Подключение локальной сети, выбранной в качестве частной сети имеет более одного IP-адреса. Измените параметры настройки подключения к локальной сети. Ошибка шифрования данных при попытке подключения 768The. 769The указанное назначение недостижимо. 770The удаленный компьютер отверг попытки подключения. Попытка 771The подключения не удалась, поскольку сеть перегружена. Сетевое оборудование 772The удаленного компьютера несовместима с типом запрашиваемого вызова. 773The попытка подключения не удалась из-за изменения адреса назначения. 774The попытка подключения не удалась из-за временной ошибки. Попробуйте выполнить подключение вызова again.775The было блокировано удаленным компьютером. Вызов 776The подключиться не удалось, поскольку удаленный компьютер вошел в «не беспокоить». 777The попытка подключения не удалась, поскольку модем (или другое устройство связи на удаленном компьютере не по порядку. 778It не удалось проверить подлинность сервера. 780An предпринята попытка функция недопустима для этого подключения. Общий доступ к подключению к 782Internet (ICS и брандмауэра подключения к Интернету (ICF нельзя включить маршрутизацию и удаленный доступ включен на этом компьютере. Чтобы включить ICS или ICF, сначала отключите службы маршрутизации и удаленного доступа. Дополнительные сведения о службе маршрутизации и удаленного доступа ICS или ICF, содержатся в справке. Не удается разрешить общий доступ к подключению к 783Internet. Подключения к локальной сети, выбранной в качестве частной сети либо не представлены, либо отключен от сети. Пожалуйста, убедитесь, что Сетевой адаптер подключен перед разрешением общего доступа к подключению Интернета. 784You не удается установить удаленное подключение во время входа в систему, так как он настроен на использование имени пользователя, отличной от той, на смарт-карте. Если вы хотите использовать его во время входа в систему, необходимо настроить его для использования имя пользователя на смарт-карте. 785You не может установить удаленное подключение во время входа в систему, так как он не настроен на использование смарт-карты. Если вы хотите использовать его во время входа в систему, необходимо изменить свойства этого подключения, чтобы использовались данные смарт-карты. 786The Попытка L2TP-подключения не удалась, поскольку отсутствует допустимый сертификат на вашем компьютере для проверки подлинности. 787The Попытка L2TP-подключения не удалась, поскольку не удалось проверить подлинность удаленного компьютера на уровне безопасности. 788The Попытка L2TP-подключения не удалась, поскольку на уровне безопасности не удалось согласовать параметры с удаленным компьютером. 789The Попытка L2TP-подключения не удалась из-за ошибки, произошедшей на уровне безопасности во время согласований с удаленным компьютером. 790The Попытка L2TP-подключения не удалась из-за ошибки проверки сертификатов. 791The Попытка L2TP-подключения не удается из-за политики безопасности для подключения не найден. 792The Попытка L2TP-подключения не удалась, поскольку истекло время согласования режима безопасности. 793The Попытка L2TP-подключения не удалась из-за ошибки согласования режима безопасности. Атрибут 794The в рамке протокол RADIUS для этого пользователя имеет значение не PPP. Неправильный 795The туннеля RADIUS-атрибут Type для данного пользователя. 796The службы RADIUS-атрибут Type для этого пользователя не является ни Framed ни Callback Framed. 797A к удаленному компьютеру не удалось подключиться, поскольку модем не найден или занят. Для получения справки нажмите кнопку Подробнее, или поиска центра справки и поддержки для номера ошибки. Не удалось найти сертификат 798A, который может быть использован с протоколом расширенной проверки подлинности. Общий доступ к подключению к 799Internet (ICS не включена из-за конфликтов IP-адресов сети. ICS требует, чтобы узел был настроен на использование адреса 192.168.0.1. Пожалуйста, убедитесь, что никакой другой клиент в сети настроен на использование адреса 192.168.0.1. 800Unable для установления VPN-подключения. VPN-сервер может быть недоступен или неправильно настроены параметры безопасности для данного подключения. 801This подключение настроено на проверку подключаемого сервера, однако Windows не удается проверить цифрового сертификата, отправленного по server.802The плата не распознана. Проверьте, что карта вставлена правильно и помещается tightly.803The PEAP конфигурации хранятся в файле cookie сеанса не соответствует configuration.804The удостоверение PEAP, хранящееся в файле cookie сеанса не соответствует текущим текущего сеанса IDENTITY.805You не удается установить удаленное подключение во время входа в систему, так как он настроен на использование вошедшего пользователя credentials.806A соединение между компьютером и VPN-сервер был запущен, но VPN-подключение не может быть завершена. Наиболее распространенной причиной для этого является, по крайней мере один Интернет устройств (например, брандмауэр или маршрутизатор) между локальным компьютером и VPN-сервера не настроена на поддержку пакетов протоколов протоколом (GRE). Если ошибка повторится, обратитесь к администратору сети или Интернета служба provider.807The сетевого подключения между компьютером и VPN-сервер был прерван. Это может быть вызвано проблемой в передачу VPN и обычно является результатом задержки Интернета или просто, что VPN-сервер достиг емкости. Повторите попытку подключения к VPN-серверу. Если ошибка повторится, обратитесь к администратору виртуальной частной сети и проанализируйте качество сетевого connectivity.808The сетевого подключения между компьютером и VPN-Подключение сервера не может быть установлено из-за отказа подключения удаленного сервера. Обычно причиной этого является несоответствие конфигурации сервера и параметров подключения. Обратитесь к администратору удаленного сервера, чтобы проверить конфигурацию сервера и подключения settings.809The сетевого подключения между компьютером и VPN-серверу не удалось установить, поскольку удаленный сервер не отвечает. Это может быть вызвано одной из сетевых устройств (например, брандмауэры, NAT, маршрутизаторы, и т.д.) между локальным компьютером и удаленным сервером не настроен для разрешения VPN-подключений. Обратитесь к администратору или поставщиком услуг, чтобы определить, какие устройства могут быть причиной problem.810A сетевое подключение компьютера VPN-сервер был запущен, а VPN-подключение не было завершено. Обычно причиной этого является использование неверного или просроченного сертификата для проверки подлинности между клиентом и сервером. Обратитесь к администратору, чтобы обеспечить valid.811The сетевое подключение компьютера сертификат, используемый для проверки подлинности и VPN-серверу не удалось установить, поскольку удаленный сервер не отвечает. Обычно причиной неполадки предварительного ключа между клиентом и сервером. Чтобы гарантировать правильность, можно сказать, что в цикле связи IP-безопасность (IPSec) используется предварительный ключ. Получите помощь администратору, чтобы определить, где неполадки предварительного ключа, originating.812The подключение не выполнено из-за политики, настроенной на сервере RAS/VPN. В частности метод проверки подлинности, используемый сервером для проверки имени пользователя и пароля может не соответствовать метод проверки подлинности настроен в профиль подключения. Пожалуйста, обратитесь к администратору сервера удаленного доступа и сообщите ему об этом error.813You предпринята попытка установить второе высокоскоростное подключение во время предыдущего высокоскоростное подключение уже установлено с помощью одного устройства или порт. Разъедините первое подключение и затем заново установить connection.814The основной подключение Ethernet, необходимое для высокоскоростного подключения не найден. Устанавливайте и включайте Ethernet на компьютере не удалось установить адаптера компьютера через папке Сетевые подключения, прежде чем этот connection.815The высокоскоростное сетевое подключение, поскольку удаленный сервер не отвечает. Это может быть вызвано недопустимое значение для поля «Имя службы» для этого подключения. Обратитесь к поставщику услуг Интернета и узнать правильное значение для данного поля и в Properties.816A подключения функция или настройка, предпринята попытка включить это обновление больше не поддерживается удаление service.817Cannot удаленного доступа подключение при connected.818The клиент принудительной защиты доступа к сети (NAP) не удалось создать системные ресурсы для подключений удаленного доступа. Некоторые сетевые службы или ресурсы могут оказаться недоступными. Если проблема остается, отключите и повторите попытку подключения удаленного доступа или контакт администратор удаленного доступа server.819The агент защиты сетевого доступа (NAP агент) служба была отключена или не установлена на этом компьютере. Некоторые сетевые службы или ресурсы могут оказаться недоступными. Если проблема сохранится, отключения и повторного подключения удаленного доступа или обратитесь к администратору удаленного доступа server.820The защиты сетевого доступа (NAP) не удалось зарегистрировать агент защиты сетевого доступа (NAP агент клиента принудительного использования ) службы. Некоторые сетевые службы или ресурсы могут оказаться недоступными. Если проблема сохраняется, отключите и повторить попытку установить подключение удаленного доступа или обратитесь к администратору для клиента принудительной защиты доступа к сети (NAP) server.821The удаленного доступа не удалось обработать запрос, поскольку удаленный доступ подключения не существует. Повторите попытку подключения удаленного доступа. Если ошибка повторится, убедитесь в том, что можно подключиться к Интернету, и обратиться к администратору клиент принудительной защиты доступа к сети (NAP) server.822The удаленного доступа не отвечает. Некоторые сетевые службы или ресурсы могут оказаться недоступными. Если ошибка повторится, отключения и повторного подключения удаленного доступа или обратитесь к администратору удаленного доступа server.823Received Привязки является привязка invalid.824Crypto не (протокол Tunnelling) received.825Point точка PPTP) несовместим с IPv6. Измените тип виртуальной частной сети на два туннельным (L2TP Layer Protocol)Примечание в этом сообщении об ошибке 8255, слово «Tunnelling» содержится слово «Туннельный.» Сбой при проверке 826EAPTLS кэшированных учетных данных. Пожалуйста credentials.827The отменить кэширование подключений L2TP/IPsec невозможно, поскольку служба модулей ключей IPSec AuthIP и IKE и базовый механизм фильтрации служба не запущена. Эти службы необходимы для установления подключения L2TP/IPSec. Пожалуйста, убедитесь, что эти службы были запущены до дозвона подключенияОбратите внимание в этом сообщении об ошибке 827, слово «dialling» содержится слово «вызова.»

Здравствуйте, уважаемые!

Есть задача установить «телефонное» соединение с локальной сетью при помощи IAS и RRAS и с использованием протокола EAP (с использованием сертификатов компьютеров).

Вот исходные данные:
1. Домен Windows Server 2003 (режим работы леса и домена: Windows Server 2003) с установленым Microsoft CA.
2. Microsoft IAS (на одном из контроллеров домена).
3. Microsoft RRAS с подключённым модемом (обычный аналоговый модем на обычной телефонной линии).

Вот что опробовано и работает  — CHAP и EAP (MD5)

Для того, чтобы работал EAP через сертификаты, как я понял из манулов Microsoft, нужно выдать IAS’у и клиенту (RRAS’а) сертификат, используя шаблон «Компьютер» (Machine). IASу я выдал этот сертификат с помощью групповой политики (auto enrollment), а вот как выдать сертификат «Компьютер» для компьютера не входящего в домен (звонящий в LAN компьютер)?

Если следовать всё тем же мануалам, то это можно сделать с помощью веб-интерфейса моего CA. Ok, делаю:
1. Запускаю http://FQDN-of-CA/certsrv на компьютере не входящем в домен
2. На запрос авторизации ввожу имя и пароль админа домена и одновременно админа предприятия.
3. Запрос сертификата
4. расширенный запрс сертификата
5. Создать и выдать запрос к этому ЦС
6. И вот самое главное!!! В списке шаблонов сертификатов нет «Компьютер». Есть только следующие варианты:
— Администратор
— Базовое шифрование EFS
— Агент восстановления EFS
— Пользователь
— Пользователь Exchange
— Подчиненный центр сертификации
— Веб-сервер

Вопрос: Как в указанный список затащить шаблон «Компьютер»?

С увжением, Голев Роман
MCP, MCSA, MCSA: Messaging

инструкции

 

To Fix (A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)) error you need to
follow the steps below:

Шаг 1:

 
Download
(A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)) Repair Tool
   

Шаг 2:

 
Нажмите «Scan» кнопка
   

Шаг 3:

 
Нажмите ‘Исправь все‘ и вы сделали!
 

Совместимость:
Windows 10, 8.1, 8, 7, Vista, XP
Загрузить размер: 6MB
Требования: Процессор 300 МГц, 256 MB Ram, 22 MB HDD

Limitations:
This download is a free evaluation version. Full repairs starting at $19.95.

Не удалось найти сертификат, который можно использовать с этим протоколом расширяемой аутентификации. (Ошибка 798) обычно вызвано неверно настроенными системными настройками или нерегулярными записями в реестре Windows. Эта ошибка может быть исправлена ​​специальным программным обеспечением, которое восстанавливает реестр и настраивает системные настройки для восстановления стабильности

If you have A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798) then we strongly recommend that you

Download (A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)) Repair Tool.

This article contains information that shows you how to fix
A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)
both
(manually) and (automatically) , In addition, this article will help you troubleshoot some common error messages related to A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798) that you may receive.

Примечание:
Эта статья была обновлено на 2023-04-05 и ранее опубликованный под WIKI_Q210794

Содержание

  •   1. Meaning of A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)?
  •   2. Causes of A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)?
  •   3. More info on A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)

Meaning of A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)?

Ошибка или неточность, вызванная ошибкой, совершая просчеты о том, что вы делаете. Это состояние неправильного суждения или концепции в вашем поведении, которое позволяет совершать катастрофические события. В машинах ошибка — это способ измерения разницы между наблюдаемым значением или вычисленным значением события против его реального значения.

Это отклонение от правильности и точности. Когда возникают ошибки, машины терпят крах, компьютеры замораживаются и программное обеспечение перестает работать. Ошибки — это в основном непреднамеренные события. В большинстве случаев ошибки являются результатом плохого управления и подготовки.

Бывают случаи, когда вы хотите получить доступ к веб-сайту, но сталкиваетесь с раздражающей проблемой. В число этих проблем входит ошибка сертификата, и он говорит вам прекратить движение вперед, потому что он обнаружил злонамеренное намерение. Если ваш браузер не доверяет SSL-сертификату, который он встречает, он отправит вам предупреждение.

Причины ошибки сертификата:

  • Истекший сертификат безопасности
  • Date or time on the computer’s clock is beyond the expiry date of the server’s SSL certificate or the date or time is incorrect
  • Веб-сайту нельзя доверять

When you encounter a certificate error, this message will appear: “There is a problem with this website’s security certificate.” You can immediately close the webpage and do not access the site until you have verified the cause of the error.

Аутентификация Windows используется для включения безопасного метода проверки подлинности. В этом процессе имя пользователя и пароль хэшируются перед отправкой по сети. Клиентский браузер отправляет очень сильную хешированную версию пароля пользователя в криптографическом обмене с вашим веб-сервером. Используются два поддерживаемых протокола; Протокол Kerberos и Протокол NTLM.

Ошибка проверки подлинности Windows происходит по ряду причин. Возможно, это связано с тем, что аутентификация Windows не включена. Остальные ошибки могут быть отнесены к соответствующему протоколу, используемому в процессе аутентификации, и некоторым другим факторам.

Causes of A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)?

Когда вы получили предупреждение от своего браузера с указанием ошибки сертификата, вы можете сделать некоторые способы защитить себя от вредоносных атак.

Сначала определите источник ошибки. Это может быть сертификат с истекшим сроком действия или временное несоответствие между вашим компьютером и сертификатом. Исправьте эти ошибки и попробуйте перезагрузить свой сайт. Если ничего не происходит, это может быть вредоносное перенаправление на плохой веб-сайт. Обратитесь к администратору веб-сайта, если вы действительно доверяете сайту. Или вы можете попробовать открыть веб-сайт в другом браузере. Но, если вы не доверяете веб-сайту, никогда не открывайте его снова и не используйте альтернативный сайт.

Ниже приведен список наиболее распространенных проблем проверки подлинности Windows и возможных решений.

Ошибки протокола Kerberos:

  • Проблемы с SPN / UPN с протоколом Kerberos Чтобы получить SPN для учетной записи вашей службы, вам необходимо быть администратором домена Active Directory.
  • Делегирование требует согласования учетных данных. Если вы используете аутентификацию Kerberos без согласования учетных данных, будет выбрано исключение.

Ошибки протокола NTLM:

  • Согласование SSP падает в NTLM, но NTLM отключен
  • NTLM Logon Fails
  • Анонимный NTLM Logon Происходит, но анонимные вход в систему отключены по умолчанию

Другие распространенные ошибки:

  • Учетные данные клиента не установлены правильно
  • SSPI недоступен Следующие операционные системы не поддерживают проверку подлинности Windows при использовании в качестве сервера: выпуски Windows XP Home Edition, Windows XP Media Center Edition и Windows VistaHome.
  • Разработка и развертывание с различной идентификацией

More info on
A certificate could not be found that can be used with this Extensible Authentication Protocol. (Error 798)

РЕКОМЕНДУЕМЫЕ: Нажмите здесь, чтобы исправить ошибки Windows и оптимизировать производительность системы.

Thanks

no luck maybe here is a better choise. for both win 7 and win 8. According to it the certificat is good Hi,
I posted this on Azure forim with

Ошибка протокола расширяемой аутентификации 7001


Сертификат сертификата клиента Сертификат RSA игнорируется при установке ECC

На этот раз клиент завершает рукопожатие, находит RSA для аутентификации клиента, я попытался удалить сертификат ECC и снова попробовал … cert и передал его обратно в LB для аутентификации.

Таким образом, у нас есть три сертификата CA1 / 2 RSA и CA3. Итак, у нас есть наша цепочка Cert для RSA, загружаемая в So, считая, что что-то не так с тем, как LB запрашивал настройку для выполнения ECC, поэтому прекрасное разделение цепей. балансировщик нагрузки и новый сертификат, выданный клиенту из CA1 …


о типе аутентификации ntlm в протоколе msrpc

the registry?) to  let msrpc protocol  use clear text in Windows 7? I noticed msrpc protocol use ntlm authentication type to encrypt data in Windows 7 by default. And in Windows xp ,it use clear text by default. 
Есть ли способ (изменить Hi ..


Сертификат компьютера протокола L2TP

Соединения, которые используют протокол L2TP через IPSec, требуют от трестов на обоих ваших компьютерах в качестве альтернативы.

  I just don’t know installation of a machine certificate, also known as a computer certificate. After some looking around I find this to them with my laptop from across the internet. Small cost $, PSK is free.

объяснение

This computer cannot accept Layer Two Tunneling Protocol (L2TP) virtual private L2TP VPN connections on this computer.Click to expand… I don’t mind using certificates if I can get how to do either. User Action

Установите сертификат компьютера для сетевых вызовов (VPN), поскольку он не имеет установленного сертификата компьютера L2TP. Есть идеи?

  Подписанные сертификаты, но вместо этого я могу использовать предварительно разделяемые ключи.

В этот момент домашняя сеть.

Я бегу, я застрял. Нет L2TP вызывает Win-XP-PRO-SP2 на нескольких компьютерах. Похоже, что получение сертификата сложным будет принято.

Возможно, вы сможете самостоятельно подписать некоторые сертификаты и добавить их на страницу http://technet.microsoft.com/en-us/library/bb742553.aspx, где некоторые из них объясняются. В журнале событий я нахожу предупреждение

Событие: 20192 — Источник: Удаленный доступ

Сертификат не найден. Я хочу иметь возможность удаленно подключаться к ним легко или предварительно разделяемые ключи, если это решение проще.


Вопрос с сертификатом аутентификации

Благодарю.

  Привет, Http://vbaexpress.com/forum/showthread.php?t=9545

НТН

  High and still run my program (which is full of macros). Take a look attach a «trusted» certificate to my program?

I want them to be able to keep their setting on welcome to the board! Is there a way that I can at Malcolm’s article here…


Проверка подлинности HTTP-сертификата

случая, который я объясню ниже. Всем привет,

У меня проблема с разрешением

Как я могу это сделать?

заранее спасибо

Я ценю любые предложения, чтобы выяснить эту ситуацию?


Ошибка при выполнении .msu: сертификат для подписчика сообщения недействителен или не найден

Уиллис

Found the answer thanks in advance. Many thanks for your time. We are playing around with the Windows 8 Enterprise Evaluation.  We are the signer of the message is invalid or not found. Greetings all and trying to install

Windows6.1-KB958830-x64-RefreshPkg.msu

но мы пробовали другие пакеты с теми же результатами.

Обновление Windows Installer Автономный

Установщик обнаружил ошибку: 0x80096002

Сертификат для этой темы: 
http://social.technet.microsoft.com/Forums/en-US/w8itprogeneral/thread/aee38b36-6e61-4ad3-b26c-cbb43b0c83f0

Уиллис


[Tera Rising] Ошибка аутентификации сертификата.

It’s very annoying and I happening for awhile… Restarted reinstalling the game. Everytime i open the Launcher, It says «Certificate multiple times. Nothing is working.

I even tried Authentication Failed, Please reinstall to correct this problem. But it doesn’t work aswell.

  Tera уже обновила мою Windows XP 32Bit. Даже обновил Roots December 2011.

Это была поддержка Rising — http://support.enmasse.com/tera ИЛИ http://tera.enmasse.com/community


Как автоматизировать проверку подлинности пользователя для удаленных пользователей?

сертификаты аутентификации пользователей через внутренние центры ADCS SHA1. До сих пор мой работодатель все еще выпускает SHA1


SSL-аутентификация с использованием сертификата клиента, не срабатывающего на новой новой Yoga 2 Pro

Back to the old issued the same way.First Y2P worked without a glitch second one does not. Any ideas?  

Решено! Какой замечательный ноутбук. А потом, мой SSD, исчезнувший от системы, не смог

ИТ-ребята сказали, что у них никогда не было такой проблемы, после того, как сотни сертификатов на решение. Идите ASUS, все работает нормально. boot, поэтому я заменил первую йогу и то же, что и в магазине.


Компонент протокола RDP X.224 обнаружил ошибку в потоке протокола и отключил клиент. Идентификатор события: 50

Это сводит меня с ума. Этот ПК всегда должен быть включен для видеозаписи, но один раз заранее!

Спасибо за мой рабочий стол для дядюшек. Здравствуй,

У меня странная проблема, пока Windows автоматически перезагрузится, и я просто не могу точно узнать, почему. Иногда мы пропускаем дни записи, в то время как мы не используем этот ПК для других вещей.


Компонент протокола RDP X.224 обнаружил ошибку в потоке протокола и отключил клиент.

Здравствуйте,

 

Включите ли вы

Аутентификация IEEE 802.1x?

 
Что касается этой проблемы, я предлагаю обновить драйвер сетевого адаптера вручную на ПК Windows 7.

Также обновите драйвер маршрутизатора и прошивку.

 
Если это может быть полезно для других членов сообщества, читающих эту тему. проблема сохраняется, вы можете отключить TCP Offload.


Почему Windows 7 не видит сертификат аутентификации клиента при подключении к беспроводной сети?

Есть ли способ заставить его соответствовать всем требованиям для подключения, но Windows 7 не будет использовать его. Является ли это устройствами Windows 7, похоже, не хотят использовать созданный сертификат. При попытке подключения я получаю сообщение об ошибке: «сертификат, необходимый для подключения к этой сети, не может быть найден на вашем компьютере». Все работает на устройствах Windows 8.1 и MAC OSX, но

Ive подтвердил, что сертификат пользователя находится в личном магазине и просматривает все сертификаты в магазине? почему-то игнорируется?


WLAN error message: «Certificate not found»

Everything seems to be working fine, however I’ve any solutions for this? Many thanks…….!

I thought at first that it just meant that I needed with the name «C&W HKT Securnet CA Root», with an expiry date 16.10.2010. The signal is there, with the little ball to put my DSL code in, but it appears that’s not enough.

When I try to uncheck the button that’s next to it, it won’t allow me. Does anyone have yet to have it working on wireless lan. Just bought a used IBM T41 Thinkpad, which swinging it’s heart out in the icon tray.

Hi everyone, I have to say I’m more than satisfied with.

Problem is, I get this message coming up all the time saying: «No Certificate has been found». On further checking in the WLAN properties menu there is a certificate listed my first post.


Как вы можете просмотреть сертификат сайта с ошибкой сертификата, не посещая его?


SSL-сертификат за брандмауэром. Предотвращение ошибки сертификата.

Или вы можете настроить собственный сервер сертификатов, а домен хоста — также company.com (мы просто запускаем отдельный внутренний и внешний DNS)

  I’m setting up a company forum on an internal machine behind the company’s firewall. Obviously, I can’t have the common name on the certificate be everyone. How can I prevent the inevitable «domain name mismatch» error when creating a certificate for the machine behind the firewall?

  Do you really need SSL if you’re behind a firewall?

Используя стандартное соглашение об именах, внутренняя машина будет machine.local, а внешним FQDN будет machine.company.com.

Эй, самозаверяющие, затем настройте клиентов, чтобы доверять вашему собственному серверу сертификатов. Вы можете создать отдельный самозаверяющий сертификат machine.local, потому что нет способа заставить это имя разрешаться извне. Я просто сделал что-то подобное сегодня на работе, но, к счастью, наш внутренний и вручную установил его на клиентов.


Intel (R) USB 3.0 eXtensible Host Controller (ошибка 10)

У него будет время, и контроллер не будет работать. У меня есть MSI Z77 GD55

Это совершенно новый 10. Номер поставщика VEN VEN и DEV. Все остальное информация об аппаратном устройстве для устройства в диспетчере устройств)?

Устройство построено, и он не подберет контроллер USB 3. Я установил разные драйверы. У вас есть код устройства для контроллера (см. Невозможно запустить. Ошибка 8086.


Сертификат конечной сущности внешних веб-сайтов, подписанный внутренним сертификатом Сервера центра сертификации — Неправильно

All SSL sites appeared domain, applied no GPOs, manually updated CRL and pulled down updated certs with rootsupd.exe. It always attempts to use this rouge CA cert to sign the websites cert. Any assistance would be much appreciated.

Я сбросил корневые сертификаты различными способами, удалив машины из этой системы.


Больше отверстий, найденных в протоколе безопасности SSL в Интернете

Этот тип атаки может позволить злоумышленнику украсть пароли, захватить онлайновую банковскую сессию или даже выпустить обновление браузера Firefox, содержащее вредоносный код, говорят исследователи.

More Holes Found in SSL (Secure Sockets Layer) encryption protocol used to secure communications on the Internet. At the Black Hat conference in Las Vegas on Thursday, researchers unveiled a number of Security researchers have found some serious flaws in software that uses the Web’s SSL Security Protocol.

атаки, которые могут быть использованы для защиты безопасного трафика между веб-сайтами и браузерами.


Невозможно установить Root CA Certificate — сертификат не может быть проверен до доверенного центра сертификации.

Encounter error: «Untrusted Certificate».  «This certificate cannot be verified up to a trusted certificate authority.»
I Anyone, any to allow the Update Root Certificate feature to update the root certificates automatically. I then restarted the IE and view the ssl site again but failed too, «Untrusted Certificate». Hi,

Я пытаюсь установить CA, способный просматривать этот корневой центр сертификации.

BUT on IE->Internet Options->Certificate->Trusted Root Certificate Authorities, I am idea ? On mmc->Certificates->Trusted Root Certificate Authorities->certificates, I root certificate on Windows 7, IE 9. Regards,

Eye Gee

Пусть для вас будут работать следующие обходные пути:

Обходной путь 1:

Измените параметры Windows, которые не могут найти этот корневой центр сертификации.

the list. have tried to install the certificate to Trusted Root Certificate Authorities->local computer and import was successful.


Если при подключении к Интернету возникла какая-либо ошибка, рекомендуется проделать действия, указанные в этой инструкции. Если эти действия вам не помогли, нужно обратиться в техническую поддержку и сообщить о том что вами было предпринято.
Ошибки любых видов подключения
691 Может возникать в следующих случаях:
1) Неверно набран логин или пароль.
2) Доступ заблокирован (н-р за СПАМ).
3) Недостаточен баланс лицевого счета.
Пути решения:
1) Проверьте реквизиты доступа в сеть. Эти данные вы получили в момент Подписки на услугу. Логин для доступа в сеть начинается на «ppp…».
2) Возможно, у Вас отрицательный баланс. Проверить и пополнить свой лицевой счет можно в кабинете личной статистики абонента по адресу: http://stream.ru/, установив соединение с гостевыми реквизитами: логин: guest@mtu и пароль: mtu
3) Возможно, Вас заблокировали за нарушения условий договора. Необходимо зайти в личный кабинет, как описано в предыдущем пункте, и проверить состояние подключения.
4) Возможно доступ с данными реквизитами временно блокирован из-за частых попыток подключения с неверно введённым паролем. Необходимо подождать 15-30 минут и повторить попытку подключения снова.
________________________________________
718 Пути решения:
1) Попробуйте пересоздать подключение.
________________________________________
733 Может возникать в следующих случаях:
1) Некорректно настроено подключение для доступа в интернет.
Пути решения:
1) Зайти в меню “Пуск”, далее зайти в Настройки>Панель управления>Сетевые подключения, нажать правой кнопкой по высокоскоростному соединению, используемому для выхода в сеть Интернет, выбрать “Свойства”, зайти в раздел “Сеть” и снять галочки со всех протоколов, кроме TCP/IP и QoS;
2) Попробовать пересоздать высокоскоростное соединение и ввести реквизиты для доступа в Интернет.
________________________________________
734 Может возникать в следующих случаях:
1) Некорректно настроено подключение для доступа в интернет.
Пути решения:
1) Зайти в меню “Пуск”, далее зайти в Настройки>Панель управления>Сетевые подключения, нажать правой кнопкой по высокоскоростному соединению, используемому для выхода в сеть Интернет, выбрать “Свойства”, зайти в раздел “Безопасность” и выбрать при проверке используется “Не безопасный пароль”
2) Попробовать пересоздать высокоскоростное соединение и ввести реквизиты для доступа в Интернет.
________________________________________
735 Может возникать в следующих случаях:
1) Некорректно настроено подключение для доступа в интернет.
Пути решения:
1) Зайти в меню “Пуск”, далее зайти в Настройки>Панель управления>Сетевые подключения, нажать правой кнопкой по высокоскоростному соединению, используемому для выхода в сеть Интернет, выбрать “Сеть”, выбираем “Протокол интернета TCP/IP”, зайти в свойства этого протокола и поставить галочку на опции “Получить IP-адрес автоматически”
2) Попробовать пересоздать высокоскоростное соединение и ввести реквизиты для доступа в Интернет.
________________________________________
797 Может возникать в следующих случаях:
1) Подвис модем.
2) Не установлен драйвер модема.
3) Некорректно настроено подключение для доступа в интернет.
4) Модем неисправен.
Пути решения:
1) Перезагрузка компьютера.
2) Если у вас USB-модем с wan-драйверами:
A) Перезагрузка компьютера.
B) Установить/переустановить драйвер модема.
C) пересоздать подключение к Интернету, при создании подключения необходимо выбрать именно этот модем из списка
Если же у вас любой другой модем, то эта ошибка возникает, если вместо подключения “ Через высокоскоростное подключение, запрашивающее имя пользователя и пароль” было выбрано “Подключение через обычный модем”. Удаляем старое и заново создаём “правильное” подключение.
3) Пересоздать подключение, при его создание выбрать именно ваш модем.
4) При неисправности модема (н-р на нем не горит ни одна лампа) обратиться в сервисный центр, адрес указан на гарантийном талоне.
________________________________________
Cтандартного PPPoE соединения (для всех рекомендованных нами модемов, кроме Zyxel Omni ADSL USB, AusLink 2006, HuawejSmartAXMT810 USB)
633 Может возникать в следующих случаях:
1) Активно или повисло подключение.
Пути решения:
1) Перезагрузка компьютера.
________________________________________
678/ 815 (Vista) Ответ не получен (возникает не сразу — примерно минута) Может возникать в следующих случаях:
1) Нет связи между модемом и станционным оборудованием (проверить можно по индикации лампочек на модеме, см. описание модема).
2) Нет связи между модемом и компьютером.
3) Неверно настроен модем.
4) Блокировка подключения защитными программами.
Пути решения:
1) Проверить, есть ли гудок в телефонной линии. Проверить схему подключения. Если не помогло, попробовать подключить модем к телефонной линии, отключив при этом другие устройства, подключенные к ней.
2) Проверить настройки подключения, это может быть либо “Подключение по локальной сети”, либо “Беспроводное сетевое соединение”.(В случае использования беспроводного соединения, убедитесь в том, что вы подключены именно к вашей сети).
3) Проверить настройки модема, согласно, прилагающейся инструкции.
4) Для диагностики необходимо отключить все используемые программы защиты ( рекомендуется перед этим провести полную проверку на вирусы).
________________________________________
769/ 814 (Vista) Может возникать в следующих случаях:
1) Произошло подвисание оборудования.
2) Отключено либо подключение по локальной/ беспроводной сети, либо сетевой адаптер.
3) Некорректно настроен модем.
Пути решения:
Ошибка вызвана недоступностью сетевого адаптера, используемого при этом подключении. Необходимо включить сетевой адаптер в диспетчере устройств («Панель управления» («Control Panel») — «Система» («System») — …) и повторить попытку подключения.

________________________________________
Ошибки модемных WAN-драйверов
692 Может возникать в следующих случаях:
1) Нет связи между модемом и станционным оборудованием (проверить можно по индикации лампочек на модеме, см. описание модема).
2) Подвис модем.
Пути решения:
1) Проверить, есть ли гудок в телефонной линии. Проверить схему подключения. Если не помогло, попробовать подключить модем к телефонной линии, отключив при этом другие устройства, подключенные к ней.
2) Перезагрузка компьютера.
3) Переустановка драйверов.
________________________________________
619 Может возникать в следующих случаях:
1) Неверно настроен модем.
2) Блокировка подключения защитными программами.
Пути решения:
1) Проверить настройки модема, согласно, прилагающейся инструкции.
2) Для диагностики необходимо отключить все используемые программы защиты (рекомендуется перед этим провести полную проверку на вирусы).
3) Переустановка драйверов.
________________________________________
721 Может возникать в следующих случаях:
1) Неверно настроено подключение к интернету.
2) Проблема с настройками операционной системы.
Пути решения:
1) Один из самых распространённых вирусов для такого вида подключения: изменяет логин и пароль, а также номер телефона подключения. Для исправления настроек необходимо зайти в меню “Пуск”->”Панель управления”->”Сеть и подключение к Интернету”->”Сетевые подключения”-> пр.кнопкой мыши по интересующему подключению->выбираем свойства -> вкладка “Параметры” -> ставим галочку ”Запрашивать имя пользователя, пароль сертификаты”, После этого в самом подключение проставляем верный номер телефона (обычно “1,50,3”, либо см. инструкцию к модему), вводим верные логин и пароль для подключения к Интернету. Чтоб такой ошибки не возникало впредь, необходимо установить какую-либо программу защиты. Если действия не помогли, рекомендуется переустановить драйвер модема, предварительно удалив, установленный ранее.
2) Если каким-либо образом изменяли настройки операционной системы (н-р; устанавливали или удаляли какие-то службы) рекомендуется сделать откат системы.
________________________________________
У модемов Zyxel Omni ADSL USB и AusLink 2006
769 Может возникать в следующих случаях:
1) Некорректно настроен модем.
2) Неправильно создано подключение.
Пути решения:
1) Проверить настройки согласно прилагающейся инструкции. (Zyxel:Пуск->программы->”Zyxel Omni ADSL USB” ->”Zyxel Omni ADSL USB” -> “Protocol setup” -> должно быть VPI=1, VCI=91, Encapsulation=”PPP over Ethernet LLCSnap RFC 2516”; Auslinks: Пуск->программы->”Acess Runer DSL->“Protocol setup” -> должно быть VPI=1, VCI=91, Encapsulation=”PPP over Ethernet LLCSnap RFC 2516” или “PPPoA LLCSNAP” )
2) При создание подключения , для этих моделей модемов, необходимо выбрать “Подключение через обычный модем”.
3) Переустановить драйвер модема.
________________________________________
721 Может возникать в следующих случаях:
1) Некорректно настроен модем.
2) Некорректно настроено подключение.
Пути решения:
1) Проверить настройки согласно прилагающейся инструкции. (Zyxel:Пуск->программы->”Zyxel Omni ADSL USB” ->”Zyxel Omni ADSL USB” -> “Protocol setup” -> должно быть VPI=1, VCI=91, Encapsulation=”PPP over Ethernet LLCSnap RFC 2516”; Auslinks: Пуск->программы->”Acess Runer DSL->“Protocol setup” -> должно быть VPI=1, VCI=91, Encapsulation=”PPP over Ethernet LLCSnap RFC 2516” или “PPPoA LLCSNAP” )
2) При создание подключения , для этих моделей модемов, необходимо выбрать “Подключение через обычный модем” Номер телефон должен быть – “0000000” (7 нулей) иногда “1,50”.
3) Переустановить драйвер модема.
________________________________________
У модемов Huawei Smart AX MT810 USB
680 Может возникать в следующих случаях:
1) Нет связи между модемом и станционным оборудованием (проверить можно по индикации лампочек на модеме, см. описание модема).
2) Некорректно настроено подключение.
Пути решения:
1) Проверить, есть ли гудок в телефонной линии. Проверить схему подключения. Если не помогло, попробовать подключить модем к телефонной линии, отключив при этом другие устройства, подключенные к ней.
2) Если у вас есть DialUP-модем (н-р: встроенный или просто подключенный), то возможно подключение которое вы создали, пытается обратиться не к тому модем, нужно пересоздать подключение и при создание выбрать именно ваш модем.
3) Попробовать переустановить драйвер модема.
________________________________________
651 Может возникать в следующих случаях:
1) Некорректно настроен модем.
2) Проблема с драйверами.
Пути решения:
1) Проверить настройки согласно прилагающейся инструкции.
2) Переустановить драйвер модема.

Коды стандартных ошибок Windows (весь список)
600 Начатая операция не закончена.
601 Обнаружен недопустимый дескриптор порта.
602 Указанный порт уже открыт.
603 Буфер вызывающего слишком мал.
604 Указаны недопустимые сведения.
605 Невозможно установить сведения о порте.
606 Указанный порт не подключен.
607 Обнаружено недопустимое событие.
608 Указано несуществующее устройство.
609 Указан несуществующий тип устройства.
610 Указан недопустимый буфер.
611 Указанный маршрут недоступен.
612 Указанный маршрут не распределен.
613 Указан недопустимый тип сжатия.
614 Недостаточно доступных буферов.
615 Указанный порт не найден.
616 Асинхронный запрос приостановлен.
617 Модем уже отключается.
618 Указанный порт не открыт.
619 Указанный порт не подключен.
620 Не удалось определить конечные точки.
621 Системе не удалось открыть файл телефонной книги.
622 Системе не удалось загрузить файл телефонной книги.
623 Системе не удалось найти запись телефонной книги для этого подключения.
624 Системе не удалось обновить файл телефонной книги.
625 Система обнаружила недопустимые данные в файле телефонной книги.
626 Не удалось загрузить строку.
627 Не удалось найти ключ.
628 Подключение было закрыто.
629 Подключение было закрыто удаленным компьютером.
630 Модем был отключен из-за ошибки оборудования.
631 Пользователь отключил модем.
632 Обнаружен неправильный размер структуры.
633 Модем уже используется или не настроен для исходящих подключений удаленного доступа.
634 Не удалось зарегистрировать компьютер в удаленной сети.
635 Произошла неизвестная ошибка.
636 Устройство, подключенное к порту, не соответствует ожидаемому.
637 Обнаружена строка, которую не удалось преобразовать (конвертировать).
638 Запрос просрочен.
639 Нет доступной асинхронной сети.
640 Произошла ошибка, затрагивающая NetBIOS.
641 Серверу не удалось выделить NetBIOS-ресурсы, необходимые для поддержки этого клиента.
642 Одно из компьютерных NetBIOS-имен уже зарегистрировано в удаленной сети.
643 Ошибка сетевого адаптера сервера.
644 Всплывающие сетевые сообщения получаться не будут.
645 Произошла внутренняя ошибка проверки подлинности.
646 Вход в это время дня для пользователя с данной учетной записью не разрешен.
647 Учетная запись отключена.
648 Срок действия пароля для учетной записи истек.
649 Учетная запись не имеет прав для дозвона.
650 Сервер удаленного доступа не отвечает.
651 Модем сообщил об ошибке.
652 Отклик от модема не распознан.
653 Макрос, требуемый модемом, не найден в INF-файле устройства.
654 Команда или отклик в секции INF-файла устройства ссылается на неопределенный макрос.
655 Макрос <сообщения> не найден в секции INF-файла устройства.
656 Макрос <отключения по умолчанию> в секции INF-файла устройства ссылается на неопределенный макрос.
657 Не удалось открыть INF-файл устройства.
658 Слишком длинное имя устройства в INF-файле устройства или в INI-файле носителя.
659 INI-файл носителя ссылается на неизвестное имя устройства.
660 INF-файл устройства не содержит ответов для этой команды.
661 В INF-файле устройства отсутствует команда.
662 Произошла попытка установить макрос, не перечисленный в секции INF-файла устройства.
663 INI-файл носителя ссылается на неизвестный тип устройства.
664 Недостаточно памяти.
665 Модем не настроен.
666 Модем не работает должным образом.
667 Системе не удалось прочесть INI-файл носителя.
668 Подключение было прервано.
669 Недопустимое использование параметра в INI-файле носителя.
670 Системе не удалось прочесть имя секции из INI-файла носителя.
671 Системе не удалось прочесть тип устройства из INI-файла носителя.
672 Системе не удалось прочесть имя устройства из INI-файла носителя.
673 Системе не удалось прочесть использование из INI-файла носителя.
674 Системе не удалось прочесть максимальную скорость подключения из INI-файла носителя.
675 Системе не удалось прочесть максимальную несущую скорости подключения из INI-файла носителя.
676 Телефонная линия занята.
677 Вместо модема ответил человек.
678 Ответ не получен.
679 Системе не удается определить несущую.
680 Отсутствует гудок.
681 Модем сообщает о возникновении общей ошибки.
691 Доступ запрещен, поскольку такие имя пользователя или пароль недопустимы в этом домене.
692 Произошла аппаратная ошибка модема.
695 Конечные автоматы не запущены.
696 Конечные автоматы уже запущены.
697 Цикл ответа не завершен.
699 Ответ модема вызвал переполнение буфера.
700 Развернутая команда в INF-файле устройства слишком длинна.
701 Установленная скорость подключения для модема не поддерживается этим COM-драйвером.
703 Подключению требуются некоторые данные от пользователя, но приложение не допускает взаимодействия с пользователем.
704 Недопустимый номер ответного вызова.
705 Недопустимое состояние авторизации.
707 Произошла ошибка, связанная с протоколом X.25.
708 Данная учетная запись просрочена.
709 Произошла ошибка при смене пароля домена. Возможно, пароль слишком короткий или совпадает с предыдущим.
710 При работе с этим модемом произошла последовательность ошибок переполнения.
711 Не удалось запустить диспетчер службы удаленного доступа. Дополнительная информация находится в журнале событий.
712 Инициализация двустороннего порта. Подождите несколько секунд и перезвоните.
713 Нет доступных линий ISDN.
714 Нет доступных ISDN-каналов для выполнения звонка.
715 Из-за низкого качества телефонной линии произошло слишком много ошибок.
716 IP-конфигурация службы удаленного доступа непригодна для использования.
717 Нет доступных IP-адресов в статическом пуле IP-адресов службы удаленного доступа.
718 Истекло время ожидания допустимого отклика с удаленного компьютера.
719 Подключение было прервано удаленным компьютером.
720 Попытка подключения не удалась, поскольку удаленному и локальному компьютерам не удалось согласовать управляющие протоколы PPP.
721 Удаленный компьютер не отвечает.
722 От удаленного компьютера получены недопустимые данные. Данные были проигнорированы.
723 Телефонный номер, включая префикс и суффикс, слишком длинный .
726 IPX-протокол не может быть использован для выполнения исходящих звонков на более чем одном модеме одновременно.
728 Системе не удается найти IP-адаптер.
729 Пока не будет установлен протокол IP, использовать протокол SLIP невозможно.
731 Протокол не настроен.
732 Этот компьютер и удаленный компьютер не смогли согласовать протоколы управления PPP.
733 Этот компьютер и удаленный компьютер не смогли согласовать протоколы управления PPP.
734 Протокол управления PPP-связью был прерван.
735 Запрошенный адрес был отвергнут сервером.
736 Удаленный компьютер завершил работу протокола управления.
737 Обнаружено замыкание на себя.
738 Сервер не назначил адрес.
739 Протокол проверки подлинности, требуемый удаленным сервером, не может использовать сохраненный пароль. Перезвоните и введите пароль явно.
740 Обнаружено недопустимое правило дозвона.
741 Локальный компьютер не поддерживает требуемый тип шифрования данных.
742 Удаленный компьютер не поддерживает требуемый тип шифрования данных.
743 Удаленному серверу требуется шифрование данных.
751 Номер обратного вызова содержит недопустимые символы. Допустимы только следующие 18 символов: цифры (от 0 до 9), T, P, W, (,), -, @ и символ пробела.
752 При обработке этого сценария была обнаружена синтаксическая ошибка.
753 Подключение не может быть разорвано, поскольку оно создано мультипротокольным маршрутизатором.
754 Системе не удается найти многоканальный пучок.
755 Система не может выполнить автоматический дозвон, поскольку это подключение имеет параметры для конкретного звонящего пользователя.
756 Это подключение уже выполнено.
757 Службы удаленного доступа не могут запускаться автоматически. Дополнительную информацию можно найти в журнале событий.
758 Для этого подключения уже разрешен общий доступ к подключению Интернета (ICS).
760 Произошла ошибка при разрешении маршрутизации.
761 Произошла ошибка при разрешении общего доступа к подключению Интернета.
763 Не удается разрешить общий доступ к подключению Интернета. Более чем одно подключение по локальной сети будет использовано совместно.
764 Считыватели смарт-карт не установлены.
765 Не удается разрешить общий доступ к подключению Интернета. Подключение по локальной сети уже настроено на использование IP-адреса, который распределяется автоматически.
766 Системе не удалось найти сертификат.
767 Не удается разрешить общий доступ к подключению Интернета. Подключение локальной сети, выбранной в качестве частной, настроено на использование более одного IP-адреса. Измените параметры настройки подключения к локальной сети.
768 Ошибка шифрования данных при попытке подключения.
769 Указанное назначение недостижимо.
770 Удаленный компьютер отверг попытку подключения.
771 Попытка подключиться не удалась, поскольку сеть перегружена.
772 Аппаратура удаленного компьютера несовместима с типом запрашиваемого вызова.
773 Попытка подключиться не удалась из-за изменения адреса назначения.
774 Попытка подключиться не удалась из-за временной ошибки. Попробуйте подключиться снова.
775 Подключение было блокировано удаленным компьютером.
776 Подключиться не удалось, поскольку удаленный компьютер вошел в режим « Не беспокоить ».
777 Попытка подключения не удалась, поскольку на удаленном компьютере не работает модем или другое устройство связи.
778 Невозможно проверить идентичность сервера.
779 Для выполнения исходящих звонков с помощью этого подключения используйте смарт-карту.
780 Пробная функция недопустима для этого подключения.
781 Попытка шифрования не удалась, поскольку не найден доступный сертификат.
782 В настоящий момент в качестве протокола маршрутизации используется преобразование сетевых адресов (NAT), которое требуется удалить перед использованием общего доступа к подключению к Интернету.
783 Не удается разрешить общий доступ к подключению Интернета. Подключение локальной сети, выбранной в качестве частной, либо не существует, либо разорвано. Убедитесь, что подключен сетевой адаптер.
784 Невозможно использовать это подключение во время загрузки, поскольку оно использует имя пользователя, отличное от пользователя смарт-карты. Для использования его во время загрузки измените используемое имя на имя владельца смарт-карты.
785 Невозможно использовать это подключение во время загрузки, поскольку оно настроено на использование смарт-карты. Измените свойства этого подключения, чтобы использовались данные смарт-карты.
786 Попытка L2TP-подключения не удалась, поскольку отсутствует допустимый сертификат на вашем компьютере для проверки подлинности.
787 Попытка L2TP-подключения не удалась, поскольку не удалось проверить подлинность удаленного компьютера на уровне безопасности.
788 Попытка L2TP-подключения не удалась, поскольку на уровне безопасности не удалось согласовать параметры с удаленным компьютером.
789 Попытка L2TP-подключения не удалась из-за ошибки, произошедшей на уровне безопасности во время согласований с удаленным компьютером.
790 Попытка L2TP-подключения не удалась из-за ошибки проверки сертификатов.
791 Попытка L2TP-подключения не удалась, поскольку не найдена политика безопасности.
792 Попытка L2TP-подключения не удалась, поскольку истекло время согласования режима безопасности.
793 Попытка L2TP-подключения не удалась из-за ошибки согласования режима безопасности.
794 Установленный RADIUS-атрибут « Кадрированный протокол » (Framed Protocol) для этого пользователя имеет значение не PPP.
795 Установленный RADIUS-атрибут « Тип туннеля » (Tunnel Type) для этого пользователя имеет некорректное значение.
796 Установленный RADIUS-атрибут « Тип службы » (Service Type) для этого пользователя не имеет значения ни « Кадрированный » (Framed), ни « Кадрированный для ответных вызовов » (Callback Framed).
797 Подключение к удаленному компьютеру не удалось установить из-за того, что модем не найден или занят.
798 Не удалось найти сертификат, который был бы использован с протоколом расширенной проверки подлинности (EAP).
799 Не удалось включить общий доступ к подключению Интернета (ICS) из-за конфликтов IP-адресов в сети. ICS требует, чтобы узел был настроен на использование адреса 192.168.0.1. Убедитесь, что никакой другой клиент сети не использует адрес 192.168.0.1.
800 Не удалось установить подключение к виртуальной частной сети. Недоступен сервер VPN или неправильно настроены параметры безопасности для данного подключения.

Понравилась статья? Поделить с друзьями:
  • Ошибка 798 vpn
  • Ошибка 789 калина 8 клапанов
  • Ошибка 797 при подключении континент ап
  • Ошибка 797 при подключении к интернету модем мтс
  • Ошибка 789 исправить