Ошибка 7100 mitsubishi electric

7-9

Error Code Definitions and Solutions: Codes [7000 — 7999]

7-9-1

Error Code [7100]

1. Error code definition

Total capacity error

2. Error definition and error detection method

The model total of indoor units in the system with one outdoor unit exceeds limitations.

3. Error source, cause, check method and remedy,

Error source

Outdoor unit

(1)

(2)

(3)

HWE14040

Cause

The model total of indoor units in the system with

one outdoor unit exceeds the following table.

Model

Qj Total

200 model

250 model

300 model

350 model

400 model

450 model

500 model

550 model

600 model

650 model

700 model

750 model

800 model

850 model

900 model

950 model

1000 model

1050 model

1100 model

1150 model

1200 model

1250 model

1300 model

1350 model

The model selection switches (SW5-3 — 5-8) on

the outdoor unit are set incorrectly.

SW5

Model

3

4

5

P200 model

OFF ON OFF OFF

P250 model

ON

ON OFF OFF

P300 model

OFF OFF ON OFF

P350 model

OFF ON

ON OFF

P400 model

ON

ON

ON OFF

P450 model

OFF OFF OFF ON

P500 model

ON OFF OFF ON

The outdoor unit and the auxiliary unit (OS) that

is connected to the same system are not proper-

ly connected.

1)

2)

53

69

86

96

108

121

3)

138

155

172

177

190

207

224

241

248

254

270

284

296

312

324

338

351

365

6

7

8

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON OFF

— 226 —

Check method and remedy

Check the Qj total (capacity code total) of in-

door units connected.

Check the Qj setting (capacity code) of the

connected indoor unit set by the switch (SW2

on indoor unit board).

When the model name set by the switch is dif-

ferent from that of the unit connected, turn off

the power source of the outdoor and the indoor

units, and change the setting of the Qj (capac-

ity code).

Indoor unit Qj table

Model

15

20

25

32

40

50

63

71

80

100

125

140

200

250

Check the setting for the model selection

switch on the outdoor unit (Dipswitches SW5-

3 — 5-8 on the outdoor unit control board).

Confirm that the TB3 on the OC and OS are

properly connected.

Qj

3

4

5

6

8

10

13

14

16

20

25

28

40

50

GB

Поддержание оптимальной температуры в комнате необходимо для комфортных условий. Когда
кондиционер ломается, жаркая погода может испортить весь день, потому что заставит
чувствовать себя неприятно. Следует определить код ошибки кондиционеров и провести
дальнейшую диагностику, чтобы вернуть устройство к работе.

Как определяются коды ошибки кондиционеров Mitsubishi Electric

Для того чтобы считать коды ошибок кондиционеров Mitsubishi Electric, воспользуйтесь
инструкцией производителя, а затем расшифруйте код при помощи таблицы:

P1  Неисправность датчика температуры ТН3 
Р2  Неисправность датчика, считывающего данные TH5-теплообменника 
Р4  Дренажный поддон наполнен выше нормы (также возможна неисправность датчика-поплавка CN4F) 
Р5  Неисправность помпы, установленной в дренажном отсеке 
Р6  Неправильное выполнение команды понижения или повышения температуры 
Р8  Неправильная температура установилась в теплообменнике 
Р9  Неисправность датчика, считывающего данные ТН2-теплообменника 
РА  Компрессор был аварийно и принудительно остановлен 
Е0  Невозможна передача сигнала к пульту управления 
Е1  Кнопки на пульте управления неисправны 
Е2  Адреса внутренних систем дублированы 
Е3  Адрес наружного блока указан неправильно 
Е4; Е5  Приемник сигнала с пульта управления неисправен 
Е6  Есть замыкание в соединении внутреннего и внешнего блока 
Е7  Ошибка передачи данных в системе 
Е8  Обрыв цепи около датчика приема данных 
Е9  Не получается связаться с передатчиком 
Е0  Низкий заряд батареи пульта 
ЕА  Неправильная установка электросети и соединений проводов 
ЕВ  Защита электросети от перенапряжения 
ЕС  Не получилось запустить работу системы по таймеру 
Ed  Необходимо сбросить все до базовых настроек 
ЕЕ  Невозможно передать данные на передатчик 
EF  M-NET ошибка – неправильное соединение проводов 
U1  Датчик 63Н указывает на давление выше нормы (либо температуру выше нормы) 
U1  Фатальная ошибка 
U2  Датчик 49С говорит о низком давлении при заборе воздуха или низком уровне хладагента 
U2  Компрессор работает на высокой температуре 
U3  Варистор конденсатора неисправен 
U4  В электросети датчика температуры внешнего блока есть обрыв или короткое замыкание 
U5  Датчик температуры конденсатора сигнализирует о превышении нормы 
U6  Обнаружена токовая перегрузка электросети компрессора, устройство остановлено 
U7  Датчик 49С указывает на ошибку 
U8  Принудительная остановка моторчика вентилятора, установленного во внешнем блоке 
U9; UH  Отклонение от нормы напряжения электрического тока, поступающего от сети, ошибка в показаниях датчика напряжения тока 
UA  Ошибка пускового реле компрессора 
UD  Компрессор перегрелся 
UL  Низкое давление хладагента 
UF  Слишком высокий уровень напряжения, остановка компрессора 
UP  Перегрузка электросети, принудительная остановка компрессора 
Fb  Ошибка системы программирования 
F1  Нет данных от датчика температуры ТН3 
F2  Обрыв фазы на участке L3 
F3  Неправильное соединение с внутренней платой управления – нет сигнала 
F4  Разомкнулся разъем 
F7  Нарушена последовательность в фазах шлейфа 
F8  Нестабильное напряжение сети 
F9  Нет сигнала в разъемах 
FA  Обрыв фазы на участках L2 

Ошибки кондиционеров Mitsubishi Electric на пульте ДУ 

Е0  Не получается передать команду на кондиционер 
Р1  Данные о всасываемом воздухе считываются неправильно 
Р2  Неисправность трубочек 
Р3  Системная ошибка 
Р4  Нет данных от датчика Drain 
Р5  Утечка переполнения защиты механизма 
Р6  Неправильно проведено снижение или увеличение температуры 
Р7  Системная ошибка (формирование данных) 
Р8  Обрыв соединения 

LED лампы

Статус операции Проверка выдачи кода ошибки 
LD1  Компрессор 
LD2  Регулировка температуры 
LD3  Проведение операции 63Н3 
LD4  Компрессор работает во время операции 63Н2 
LD5  Включен вентилятор 
LD6  Работает четырехходовой клапан 
LD7  Перепускной клапан 
LD8  Работает нагреватель картера 
Индикация светодиода   
Вспышка раз в 2 секунды  Неисправно питание конвертора, внешнее питание, термистор или система управления наружного блока 
Две вспышки раз в 2 секунды  Защита от короткого замыкания 
Три вспышки раз в 2 секунды  Защита от превышения нормальной температуры системы нагнетания 
Четыре вспышки раз в 2 секунды  Защита от превышения нормальной температуры термистора 
Пять вспышек раз в 2 секунды  Защита от превышения нормы давления в системе 
Семь вспышек раз в 2 секунды  Защита от случайного старта системы 
Восемь вспышек раз в 2 секунды  Защита ошибки в установке температуры 
Одна вспышка  Снизилось напряжение в электросети 
Три вспышки  Сработал режим размораживания 
Четыре вспышки  Высокая температура системы нагнетания 
Пять вспышек  Термистор наружный 
Семь вспышек  Низкая температура системы нагнетания 
Восемь вспышек  Конвертор защищается 
Девять вспышек  Инвертор проверяется 
Error Расшифровка Русский перевод
P1 Intake sensor error Ошибка датчика на входе
P2 Pipe (TH5) sensor error Ошибка датчика теплообменника ТН5 (по схеме)
P4 Drain sensor error/Float switch connector (CN4F) open Переполнение дренажного поддона, или обрыв поплавкового датчика CN4F
P5 Drain pump error Ошибка дренажной помпы
P6 Freezing/Overheating protection operation Ошибка по обмерзанию или перегреву
P8 Pipe temperature error
P9 Pipe (TH2) sensor error Ошибка по датчику теплообменника ТН2
PA Forced compressor stop(due to water leakage abnormality) Принудительная остановка компрессора (из-за переполнения дренажной системы)
E0, E3 Remote controller transmission error Нет связи с пультом управления
E1, E2 Remote controller control board error Неисправна плата пульта управления
E4, E5 Remote controller signal receiving error
E9 Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) Нет связи между внутренним и внешним блоком (Ошибка на внешнем блоке)
EE Communication error between indoor and outdoor units Отсутствует межблочная связь между внутренним и внешним блоками
U1,Ud Abnormal high pressure (63H worked)/Overheating protection operationс Высокое давление по датчику 63Н, или защита от перегрева
U2 Abnormal high discharging temperature/49C worked/insufficient refrigerant Сработал датчик 49С, очень низкое давление нагнетания, недостаток хладагента
U3, U4 Open/short of outdoor unit thermistors Обрыв, короткое замыкание термодатчика внешнего блока
U5 Abnormal temperature of heat sink Температура конденсатора не соответствует норме
U6 Compressor overcurrent interruption/Abnormal of power module Компрессор принудительно остановлен по токовой перегрузке, неисправен силвой модуль
U7 Abnormality of super heat due to low discharge temperatureAbnormal high discharging temperature/49C worked/insufficient refrigerant Сработал датчик 49С / очень низкое давление нагнетания / недостаток хладагента
U8 Outdoor unit fan protection stop Двигатель вентилятора внешнего блока остановлен
U9, UH Abnormality such as overvoltage or voltage shortage and abnormal synchronous signal to main circuit/Current sensor error Повышенное / пониженное напряжение питания, неисправность токового датчика
UF Compressor overcurrent interruption (When compressor locked) Компрессор остановлен из-за токовой перегрузки, компрессор заклинило
UP Compressor overcurrent interruption Остановка компрессора из-за перегрузки по току
Fb Indoor unit control system error (memory error, etc.) Ошибка платы управления внутреннего блока (EEPROM и т.д.)

Определить ошибку в бытовых сплит системах можно по миганию индикаторов на панели внутреннего блока.

Получить расшифровку всех возможных кодов холодильного оборудования Mitsubishi Electric можно на сайте:

Язык оригинальной документации — английский.

Компания Mitsubishi Electric разработала программу для телефонов с помощью которой можно получить расшифровку кода ошибок.

Какая ошибка у вашего кондиционера?

Код ошибки: P1

Ошибка датчика на входе

Нарушена герметичность датчика. Соединительный кабель замыкает

Проверить датчик на работоспособность, При необходимости заменить датчик

Код ошибки: P2

Ошибка датчика теплообменника

Датчик температуры некорректно подключен или поврежден

Проверить датчик на работоспособность, При необходимости заменить датчик

Код ошибки: P4

Дренажный поддон переполнен, случился обрыв поплавкового датчика CN4F

Возможно забит слив

Проверить дренаж на засоренность

Решение не помогло или нужно больше информации?
Проконсультируйтесь со специалистом или вызовите мастера!

Код ошибки: P5

Ошибка дренажной помпы

Двигатель дренажа работает некорректно

Код ошибки: P6

Ошибка по обмерзанию или перегреву

Перегрев устройства Температура окружающей среды слишком высокая. Работа вентилятора осуществляется неверно. Загрязнение теплообменника

Код ошибки: P8

Температурный режим превысил норму

Сопротивление датчика превысило норму

Проверить температурный датчик на исправность

Код ошибки: P9

Ошибка по датчику теплообменника ТН2

Датчик и соединительный кабель замыкает

Код ошибки: PA

Принудительная остановка компрессора (из-за переполнения дренажной системы)

Код ошибки: E0/E3

Нет связи с пультом управления

Поменять батарейки пульта ду

Код ошибки: E1/E2

Неисправна плата пульта управления

Плата управления неисправна. Кабель связи неисправен. Рядом с кабелем проходит другой кабель и создает электромагнитные помехи

Код ошибки: E4/E5

Целостность датчиков температуры нарушено. Нарушение в напряжении сети

Проверить межблочное соединение. Поверить датчики температуры и давления.

Код ошибки: E9

Нет связи между внутренним и внешним блоком

Ошибка на внешнем блоке. Обрыв цепи.

Код ошибки: EE

Отсутствует межблочная связь между внутренним и внешним блоками

Сбой работы разъемов. Низкое напряжении на линии.

Код ошибки: U1/Ud

Высокое давление по датчику 63Н, или защита от перегрева

Возможно в системе избыток хладагента

Код ошибки: U2

Сработал датчик 49С, очень низкое давление нагнетания

Недостаток хладагента в системе

Код ошибки: U3/U4

Датчик температуры во внешнем блоке замкнул

Датчик температуры некорректно подключен или поврежден

Код ошибки: U5

Температура конденсатора не соответствует норме

Недостаток фреона в системе, загрязнении фильтров и испарителя

Обслуживание вентиляции

Код ошибки: U6

По токовой перезагрузки компрессор замкнул, неисправен силовой модуль

Причиной может служить загрязнение фильтров, крыльчатки вентиляторов, поверхность теплообменника.

Код ошибки: U7

Низкое давление нагнетания

Недостаток хладагента в системе

Код ошибки: U8

Двигатель вентилятора внешнего блока остановлен

Блокировка двигателя вентилятора, перегрузка или поврежденное соединение

Обслуживание вентиляции

Код ошибки: U9/UH

Неисправность токового датчика

Повышенное или пониженное напряжение питания,

Обслуживание вентиляции

Код ошибки: UF

Компрессор остановлен из-за токовой перегрузки

Обслуживание вентиляции

Код ошибки: UP

Остановка компрессора из-за перегрузки по току

Причиной может служить загрязнение фильтров, крыльчатки вентиляторов, поверхность теплообменника.

Код ошибки: Fb

Ошибка платы управления внутреннего блока



Прилепить пост

Сообщение Сергей Александрович » Вт окт 13, 2020 7:13 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

a65rivn писал(а):Хорошенько проверьте разъем от проявки на передней части(когда вынимаете проявку его разъединяете).

Разъем в порядке, копаю дальше

Аватар пользователя

Сергей Александрович

  

Увидел чернила

  • В сети
  • Сайт

Прилепить пост

Сообщение Сергей Александрович » Вт июн 15, 2021 2:00 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

a65rivn писал(а):Хорошенько проверьте разъем от проявки на передней части(когда вынимаете проявку его разъединяете).

Вышел из строя форматер, брак в работе заправщика, после очистки не продул плату датчика тонера

Аватар пользователя

Сергей Александрович

  

Увидел чернила

  • В сети
  • Сайт



Прилепить пост

Сообщение Сергей Александрович » Вт июн 15, 2021 2:57 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

dviz писал(а):И из-за этого форматер(?) вышел из строя?

Поставили форматер с ошибкой в такой же принтер, тоже самое пишет, видимо тонер на плате датчика убил его, других причин не вижу

Аватар пользователя

Сергей Александрович

  

Увидел чернила

  • В сети
  • Сайт



  • [SCANNER ERROR] Lamp Error Kyocera FS-1016

    мастерчип в форуме Принтеры, МФУ, факсы, копиры формата A4

    3
    6736

    Усатый Полосатый
    Перейти к последнему сообщению
    Вс окт 28, 2018 11:08 pm
  • Kyocera 1035 «бледная» печать

    srMax в форуме Принтеры, МФУ, факсы, копиры формата A4

    2
    14198

    srMax
    Перейти к последнему сообщению
    Пт янв 23, 2015 2:49 pm
  • Kyocera FS-1120d индикатор «Нет бумаги»

    vs-dos в форуме Принтеры, МФУ, факсы, копиры формата A4

    11
    15427

    СТРОНЦИЙ
    Перейти к последнему сообщению
    Вт ноя 02, 2021 2:24 pm
  • Kyocera Ecosys M2635dn «поворот» изображения

    Искатель в форуме Принтеры, МФУ, факсы, копиры формата A4

    10
    6312

    MatrixAgent
    Перейти к последнему сообщению
    Ср апр 08, 2020 5:18 am
  • Стирание вала ведущей шестерни в «печке» Kyocera M2035dn

    Грецкий орех в форуме Принтеры, МФУ, факсы, копиры формата A4

    12
    3777

    СТРОНЦИЙ
    Перейти к последнему сообщению
    Пн дек 13, 2021 3:35 pm

Вернуться в Принтеры, МФУ, копиры формата A3

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 15

7-8

Error Code Definitions and Solutions: Codes [7000 — 7999]

7-8-1

Error Code [7100]

1. Error code definition

Total capacity error

2. Error definition and error detection method

The model total of indoor units in the system with one outdoor unit exceeds limitations.

3. Error source, cause, check method and remedy,

Error source

Outdoor unit

(1)

The model total of indoor units in the sys-

tem with one outdoor unit exceeds the fol-

lowing table.

(2)

The model selection switches (SW5-3 — 5-

6) on the outdoor unit are set incorrectly.

(3)

The outdoor unit and the auxiliary unit

(OS) that is connected to the same system

are not properly connected.

HWE14080

Cause

Capacity Total

Model

72 model

93

96 model

124

120 model

156

144 model

187

168 model

218

192 model

249

216 model

280

240 model

312

264 model

343

288 model

374

312 model

405

336 model

436

360 model

468

SW5

Model

3

4

5

6

72 model

OFF ON OFF OFF

96 model

ON

ON

OFF OFF

120 model

OFF OFF ON

OFF

144 model

ON

ON

ON

OFF

168 model

OFF OFF OFF

ON

— 226 —

Check method and remedy

1)

Check the model total (capacity code total) of in-

door units connected.

2)

Check the model name (capacity code) of the

connected indoor unit set by the switch (SW2 on

indoor unit board).

When the model name set by the switch is differ-

ent from that of the unit connected, turn off the

power source of the outdoor and the indoor units,

and change the setting of the model name (ca-

pacity code).

Check the setting for the model selection switch

on the outdoor unit (Dipswitches SW5-3 — 5-6 on

the outdoor unit control board).

Confirm that the TB3 on the OC and OS are

properly connected.

GB

  1. 10-07-2019


    #1

    lanierboy is offline


    Senior Tech

    100+ Posts


    Rep Power
    33

    C8800 Error code DF7100 and 6002i

    Good Morning all,

    we have two 6002i machines at the same customer with the internal finisher DF7100 fitted that appear to have the same issue.

    we keep getting C8800 Main program error engine/DF. This however co-insides with the machine having a paper jam.
    So customer has a jam then 1 or 2 mins later C8800.

    So far we have:
    Replaced the complete finisher on one of the machines
    Update all firmware
    checked all terminals all ok.

    The only thing we have not replaced yet is the engine pwb but I can see this being the problem on two machines and at the same customer?.

    Has any of you had this or a similar issue before? resolution??

    All help appreciated.

    Regards

    Phil


  2. 10-07-2019


    #2

    GeneOR95 is offline


    Senior Tech

    100+ Posts


    Rep Power
    14

    Re: C8800 Error code DF7100 and 6002i

    The #2 solution in the book is firmware not up to date. Until you update the firmware with the latest version you are just chasing your tail.


  3. 10-07-2019


    #3

    Re: C8800 Error code DF7100 and 6002i

    There is a bulletin re the deformation of metal plates

    https://partner.kyoceradocumentsolut…ND_0124_SB.pdf


  4. 10-08-2019


    #4

    Re: C8800 Error code DF7100 and 6002i

    The finisher does not make a good connection with the machine , you will notice the connector «floats» on the finisher unit. Pack this out with a washer to fix the connector and bring it slighly forward. Done this many times, the MOD dosen’t work, try this.


  5. 10-09-2019


    #5

    lanierboy is offline


    Senior Tech

    100+ Posts


    Rep Power
    33

    Re: C8800 Error code DF7100 and 6002i

    Quote Originally Posted by aandy_py
    View Post

    The finisher does not make a good connection with the machine , you will notice the connector «floats» on the finisher unit. Pack this out with a washer to fix the connector and bring it slighly forward. Done this many times, the MOD dosen’t work, try this.

    Thank you all for the feedback, We were going to order a new loom assby but I will try packing out the connectors and let you know.


  6. 10-18-2019


    #6

    lanierboy is offline


    Senior Tech

    100+ Posts


    Rep Power
    33

    Re: C8800 Error code DF7100 and 6002i

    Quote Originally Posted by Ropariva
    View Post

    Hi, we have already fitted the modified plates to the machines with no change to the error occurrence.


  7. 10-21-2019


    #7

    Re: C8800 Error code DF7100 and 6002i

    Maybe in your case you are still has bad connections from DF connector or maybe wrong fitted connectors on feed image pwb YC6 and/ or YC30.




Прилепить пост

Сообщение Сергей Александрович » Вт окт 13, 2020 7:13 am

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

a65rivn писал(а):Хорошенько проверьте разъем от проявки на передней части(когда вынимаете проявку его разъединяете).

Разъем в порядке, копаю дальше

Аватар пользователя

Сергей Александрович

Увидел чернила

  • Не в сети
  • Сайт

Прилепить пост

Сообщение Сергей Александрович » Вт июн 15, 2021 2:00 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

a65rivn писал(а):Хорошенько проверьте разъем от проявки на передней части(когда вынимаете проявку его разъединяете).

Вышел из строя форматер, брак в работе заправщика, после очистки не продул плату датчика тонера

Аватар пользователя

Сергей Александрович

Увидел чернила

  • Не в сети
  • Сайт



Прилепить пост

Сообщение Сергей Александрович » Вт июн 15, 2021 2:57 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑

dviz писал(а):И из-за этого форматер(?) вышел из строя?

Поставили форматер с ошибкой в такой же принтер, тоже самое пишет, видимо тонер на плате датчика убил его, других причин не вижу

Аватар пользователя

Сергей Александрович

Увидел чернила

  • Не в сети
  • Сайт



  • Kyocera FS-1120d индикатор «Нет бумаги»

    vs-dos в форуме Принтеры, МФУ, факсы, копиры формата A4

    11
    15142

    СТРОНЦИЙ
    Перейти к последнему сообщению
    Вт ноя 02, 2021 2:24 pm
  • [SCANNER ERROR] Lamp Error Kyocera FS-1016

    мастерчип в форуме Принтеры, МФУ, факсы, копиры формата A4

    3
    6645

    Усатый Полосатый
    Перейти к последнему сообщению
    Вс окт 28, 2018 11:08 pm
  • Kyocera 1035 «бледная» печать

    srMax в форуме Принтеры, МФУ, факсы, копиры формата A4

    2
    13949

    srMax
    Перейти к последнему сообщению
    Пт янв 23, 2015 2:49 pm
  • Kyocera Ecosys M2635dn «поворот» изображения

    Искатель в форуме Принтеры, МФУ, факсы, копиры формата A4

    10
    6104

    MatrixAgent
    Перейти к последнему сообщению
    Ср апр 08, 2020 5:18 am
  • Стирание вала ведущей шестерни в «печке» Kyocera M2035dn

    Грецкий орех в форуме Принтеры, МФУ, факсы, копиры формата A4

    12
    3468

    СТРОНЦИЙ
    Перейти к последнему сообщению
    Пн дек 13, 2021 3:35 pm

Вернуться в Принтеры, МФУ, копиры формата A3

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 13

Code

Contents

7100

Toner sensor error

Sensor output value of 8 or

less.

Related parts

Toner sensor

Toner motor

Main/Engine PWB

1-4-32

2NC/2NF/2NG/2NN/3P7/3P8/3P9

Check procedures/

corrective measures

1. Check the toner sensor output by U150

(see page 1-3-53).

2. Confirm that the wiring connector is

firmly connected and, if necessary,

connect the connector all the way in.

Toner sensor and main/engine PWB

(YC9)

3. If the wiring is disconnected, shorted or

grounded, replace the wiring.

4. Check that the gears of the Developer

unit are not damaged and the spiral can

rotate.

5. Replace the Developer unit (see page 1-

5-35).

1. Draw out the toner container and

execute U135 to check the toner motor

operation (see page 1-3-50).

2. Check the drive gear can rotate or they

are not unusually loaded and, if

necessary, replace.

3. Confirm that the wiring connector is

firmly connected and, if necessary,

connect the connector all the way in.

Toner motor and main/engine PWB

(YC12)

4. If the wiring is disconnected, shorted or

grounded, replace the wiring.

5. Replace the Toner motor.

1. Check the main/engine software and

upgrade to the latest, if necessary.

2. Replace the main/engine PWB (see

page 2-2-11).

Если при работе с копировальном аппаратом у вас возникли проблемы, и система выдает код ошибки, вы можете идентифицировать ее с помощью данной таблицы.
Коды ошибок Kyocera-Mita указаны для более поздних моделей копиров. Если вы являетесь владельцем более ранней модели, необходимо к трехзначному коду ошибки прибавить знак «0».

Общие ошибки
 

Код ошибки Описание
0030 Fax control PWB system problem
0070 Fax control PWB incompatibility detection problem
0100 Backup memory read/write problem (main board)
0110 Backup memory data problem (main board)
0120 Drum EEPROM read/write problem (для 2550)
0130 Backup memory read/write problem (main PCB EEPROM) (для 1650/2050/2550)
0140 Backup memory data problem (main PCB EEPROM) (для 1650/2050/2550)
0150 Backup memory read/write problem (engine board)
0160 Backup memory data problem (engine board)
0170 Accounting count problem
0180 Machine number mismatch
0210 Communication problem between the main board and engine board (для KM-1500/1620/2020/1635/2035/1650/2050/2550/6030/8030, FS-1018/1118)
Communication problem between the main board and operation board (для KM-1525/1530/2030/2530/3530/6230/4530/5530/6330/7530)
0240 Printer board PWB communication problem
0250 Scanner network board communication problem
0280 Communication problem between the fax control PWB and main PWB
0320 Side deck communication problem
0340 Finisher communication problem
0410 Optional DP communication problem
0420 Optional first paper feeder communication problem
Large paper deck /paper feed desk communication problem /Side deck communication problem
0440 Finisher communication problem
0450 Mailbox communication problem
0470 Switchback unit communication problem
0500 Optional second paper feeder communication problem
0510 Optional third paper feeder communication problem
0600 DIMM problem (для 2530/3530)
0610 Bitmap (DIMM) problem
0620 Memory input interface problem
0630 DMA problem
0640 Hard disk drive problem
0800 Image processing problem (JAM05 is detected twice)
0820 Fax control PCB CG ROM checksum error
0830 Flash ROM program area checksum error
0860 Fax control PCB software switch checksum error
0870 Fax control PWB to main PWB high capacity data transfer problem
0880 Fax control PWB program archive problem
0890 Fax control PCB CG font archive problem
0900 Fax software incompatibility detection problem
0920 Fax file system error
0960 Developer EEPROM read/write problem (для 2550/6030/8030)
1000 Exposure lamp problem
1010 Lift motor 1 error
1020 Lift motor 2 error
1030 Lift motor 3 error
1040 Lift motor 4 error
1100 Paper deck motor 1 problem [Drawer 3]
1110 Paper deck motor 2 problem [Drawer 4]
1120 Deck right lift position problem
1130 Deck left lift position problem
1140 Side deck lift motor (going up) problem
1150 Side deck lift motor (going down) problem
1160 Large paper deck (paper feed desk) sequence problem
1170 Large paper deck (paper feed desk) incorrect type problem
2000 Main motor problem
Image forming motor problem (для 6230/4530/5530/6330/7530)
2500 Paper feed motor problem
2550 Paper conveying motor problem (для 4530/5530)
2600 Deck conveying motor /desk drive motor problem
2640 Side deck drive motor problem
3100 Scanner carriage problem
3200 Exposure lamp problem
3300 Optical system (AGC) problem
4000 Polygon motor synchronization problem
4010 Polygon motor steady-state problem
4100 BD initialization (A) problem
4110 BD initialization (B) problem
4200 BD steady-state problem
5100 Main charger problem
5110 Transfer/separation high voltage problem
5300 Broken cleaning lamp wire
5500 Drum surface potential sensor problem 1
5510 Drum surface potential sensor problem 2
5600 Drum surface potential problem 1
5610 Drum surface potential problem 2
6000 Broken fixing heater wire
6020 Abnormally high fixing unit thermistor temperature
6030 Broken fixing unit thermistor
6050 Abnormally low fixing unit thermistor temperature
6100 Broken fixing heater wire
6200 Abnormally low fixing unit thermistor temperature
6300 Abnormally high fixing unit thermistor temperature
6400 Zero-crossing signal problem
6410 Fixing unit connector insertion problem
6420 Fixing fuse cut problem
6420 Broken fixing unit thermistor wire
7100 Toner sensor problem
7300 Broken external temperature thermistor wire (для KM-1505/1510/1810/4230/5230/6230)
Toner sensor problem/ Toner hopper problem (для KM-2530/3530/3035/4035/5035/6230/4530/5530/6330/7530/6030/8030)
7310 Short-circuited external temperature thermistor
7400 Image formation unit connector insertion problem
Developing unit connector insertion problem (для 2550)
7410 Drum unit connector insertion problem
7750 Drum type mismatch problem A (для 1635/2035)
7760 Drum type mismatch problem B (для 1635/2035)
7800 Broken external temperature thermistor
7810 Short-circuited external temperature thermistor

KM-1500, FS-1018/1118 (KM-1820)

Код ошибки Описание
0220 Communication problem between the main board and operation board (для 1018/1118)
F— Controller system error (для 1018/1118)
F010 ROM checksum error (для 1118)
F012
7980 Waste toner reservoir overflow problem (when the total number of copies is less than 100 thousand sheets)
7990 Waste toner reservoir overflow problem (when the total number of copies is 100 thousand sheets or more)

KM-1505/1510/1810/1525/1530/2030

Код ошибки Описание
0210 Printer board communication problem (для 1505/1510/1810)
0400 DIMM problem
0410 Bitmap problem
0430 DMA problem
1040 Optical system problem (AGC)

Kyocera-Mita 3035/4035/5035

Код ошибки Описание
0100 Operation unit PCB backup memory read/write error
0110 Operation unit PCB backup memory data problem
0210 MMI communication problem
0320 Energy save communication problem
7450 Image formation unit fuse cut problem

Kyocera Mita 4230/5230

Код ошибки Описание
0010 Memory copy PCB 1 communication problem
0030 Memory copy PCB 2 communication problem
0100 RAM/ROM problem
0220 Communication problem between the engine PCB and main PCB
0230 Scanner communication problem
0260 Memory copy PCB 1 communication problem
0320 Large paper deck communication problem /Paper feed desk communication problem
0360 Memory copy PCB 2 communication problem
0370 Communication microcomputer problem
1040 Optical system problem (AGC)
2100 Paper conveying motor problem
2200 Side registration motor problem
2300 Paper feed motor problem
2310 Desk drive motor problem
2410 Upper lift motor problem
2420 Lower lift motor problem
2430 Upper desk lift motor problem
2440 Lower desk lift motor problem
3320 Scanner watchdog problem
3400 Original detection position problem
7400 Toner hopper problem
9200 Deck paper conveying motor problem
9210 Paper deck motor 1 problem
9220 Paper deck motor 2 problem
9230 Right lift position problem
9240 Left lift position problem

Kyocera-Mita 6030/8030

Код ошибки Описание
0060 Main PWB type mismatch error
0130 Backup memory (EEPROM) device problem
0140 Backup memory (EEPROM) data problem
0220 Scanner communication problem
0330 Relay board communication problem
0460 Duplex unit communication problem
0470 Sheet inserter communication problem (optional document finisher)
0500 Paper feed unit communication error (cassette 1 and 2)
0510 Paper feed unit communication error (cassette 3 and 4)
0700 Side feeder EEPROM error (optional side feeder)
0750 Document finisher EEPROM error
0970 Cleaning unit EEPROM error
1200 Duplex side registration motor error
2100 Developing motor error
2200 Drive motor error
2300 Fuser motor error
2550 Transfer motor error
3210 CIS lamp problem
3310 Optical system (AGC) problem (DP)
3500 Communication error between scanner and SHD
3900 Backup memory read/write error (scanner PWB)
3910
4120 BD initialization (C) problem
7200 Broken drum thermistor wire
7210 Shorted drum thermistor
9040 DP lift motor going up error
9050 DP lift motor going down error
9060 DP EEPROM error
9070 Communication problem between DP and SHD
9080 Communication problem between DP and CIS

Kyocera Mita 6230

Код ошибки Описание
0010 Memory PCB communication problem
0100 RAM/ROM problem
0260 Memory copy PCB 1 communication problem
0350 Mailbox communication problem
0370 Communication microcomputer problem
0380 Hard disk problem
0390 DIMM problem
1040 Optical system problem (AGC)
2100 Drive motor problem / Paper conveying motor problem
2200 Paper feed motor problem
2300 Large paper deck right lift motor problem
2310 Large paper deck left lift motor problem
2420 Upper lift motor problem
2430 Lower lift motor problem
6500 Broken fixing unit thermistor wire
7200 Broken drum thermistor wire
7210 Shorted drum thermistor
7220 Broken drum heater wire

KyoceraMita 6330/7530

Код ошибки Описание
1060 Large paper deck left lift motor problem
2550 Drive motor problem
7520 Shorted drum thermistor
7530 Broken drum thermistor wire

Ошибки финишеров

Код ошибки Описание
8010 Finisher paper conveying motor problem
8030 Finisher (upper) paper conveying belt problem
8140 Finisher tray elevation motor problem /Main tray problem
8170 Finisher front side registration motor problem
8180 Finisher rear side registration motor problem
Finisher rear jogger motor problem (для 4230/5230)
8190 Finisher trailing edge registration motor problem
8210 Finisher stapler motor problem
8220 Finisher rear stapler problem
8300 Document finisher centerfold unit communication problem
8310 Document finisher centerfold unit side registration guide problem
8320 Document finisher centerfold unit centering plate problem
8330 Document finisher centerfold blade problem

Ошибки финишеров KM-2530/3530/3035/4035/5035

Код ошибки Описание
8300 Booklet stitcher paper ejection motor problem
8310 Booklet stitcher elevation motor problem
8320 Booklet stitcher rear jog motor problem
8330 Booklet stitcher front jog motor problem
8340 Booklet stitcher staple motor problem
8350 Booklet stitcher batch processing motor problem
8360 Booklet stitcher stapler shift motor problem
8370 Booklet stitcher paddle motor problem
8380 Booklet stitcher folding problem
8390 Booklet stitcher backup RAM data problem
8400 Booklet stitcher incorrect type problem
8410 Booklet stitcher punch motor problem
8420 Booklet stitcher shift motor problem
8430 Booklet stitcher punch communication problem
8440 Booklet stitcher punch sensor problem
8450 Booklet stitcher side punch sensor problem
8460 Booklet stitcher punch backup RAM data problem
8470 Booklet stitcher punch dust sensor problem
8480 Booklet stitcher broken punch power source wire problem
8500 Mailbox drive motor problem

Ошибки финишера KM-6230

Код ошибки Описание
8180 Finisher rear jogger motor problem
8310 Booklet stitcher paper ejection motor problem
8320 Booklet stitcher elevation motor problem
8330 Booklet stitcher jog motor problem
8340 Booklet stitcher staple motor problem
8350 Booklet stitcher stapler unit shift motor problem
8360 Booklet stitcher stack level detection sensor problem
8370 Booklet stitcher punch motor problem
8380 Booklet stitcher punch shift motor problem
8390 Booklet stitcher swing motor problem
8400 Booklet stitcher backup RAM data problem
8410 Booklet stitcher punch unit backup RAM data problem
8420 Booklet stitcher positioning plate motor problem
8430 Booklet stitcher folding motor problem
8440 Booklet stitcher guide motor problem
8450 Booklet stitcher jog motor problem
8460 Booklet stitcher rear staple motor problem
8470 Booklet stitcher front staple motor problem
8480 Booklet stitcher thrust motor problem
8490 Booklet stitcher communication error

Ошибки финишеров KM-6330/7530/6030/8030

Код ошибки Описание
8000 Document finisher incorrect type problem (для 6330/7530)
8020 Finisher punch motor problem
8040 Finisher lower paper conveying belt problem
8150 Finisher multi job tray problem
8170 Front upper side-registration guide problem
8180 Finisher rear upper side-registration guide problem
8190 Finisher lower side-registration guide problem
8220 Finisher front clincher problem
8230 Finisher rear stapler problem
8240 Finisher rear clincher problem
  • Code: 0030
  • Description: FAX control PWB system error
    Processing with the fax software was disabled due to a software problem.
  • Causes: FAX control PWB
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, re-mount the FAX controller PWB, then turn power on. 2. Reinstall the fax software. 3. Replace the FAX control PWB.
  • Code: 0060
  • Description: Main/Engine PWB mismatch
    Unmatching engine and engine sub boards. Defective engine subboard
  • Causes: Main/Engine PWB
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Replace the main/engine PWB.
  • Code: 0100
  • Description: Backup memory device error
  • Causes: EEPROM (Main/Engine PWB)
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM on the main circuit PWB is peroperly installed on the main circuit PWB and, if not, re-install it. 3. Replace the main/engine PWB.
  • Code: 0120
  • Description: MAC address data error
    For data in which the MAC address is invalid.
  • Causes: EEPROM (Main/Engine PWB)
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check the MAC address on the network status page. 3. If it is blank, obtain an EEPROM with its MAC address written from the service support and install. 4. Replace the main/engine PWB.
  • Code: 0150
  • Description: Backup memory read/write error (main/engine PWB)
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from 2 locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Causes: EEPROM (Main/Engine PWB)
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the EEPROM is peroperly installed on the main/engine PWB and re-install it. 3. Replace the main/engine PWB. 4. Check the EEPROM and if the data are currupted, contact the service support.
  • Code: 0160
  • Description: Backup memory data error (main/engine PWB)
    Reading data from EEPROM is abnormal.
  • Causes: EEPROM
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Execute U021 — memory initializing.(see page 1-3-19) 3. If the EEPROM data are currupted, contact the service support.
  • Code: 0170
  • Description: Billing counting error
    The values on the main circuit PWB and on the engine do not match for any of charging counter, life counter, and scanner counter.
  • Causes: EEPROM. Main/Engine PWB.
  • Remedy: EEPROM 1. Check that the EEPROMs installed in the main/engine PWB are correct and, if not, use the correct EEPROM for the model. 2. If the EEPROM data are currupted, contact the service support.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 0180
  • Description: Machine number mismatch
    Machine number of main/ engine does not match.
  • Causes: Data damage of EEPROM.
  • Remedy: 1. Confirm the machine data for the main/ engine units by using U004. 2. If the serial number data of different models is alternately displayed, install the correct EEPROM in the PWB of the wrong serial number data. 3. Contact the Service Support.
  • Code: 0190
  • Description: Backup memory device error (main/engine PWB)
  • Causes: Main/Engine PWB
  • Remedy: Replace the main/engine PWB.
  • Code: 0630
  • Description: DMA error
    DMA transmission of image data does not complete within the specified period of time.
  • Causes: Main/Engine PWB
  • Remedy: 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the main/engine PWB.
  • Code: 0800
  • Description: Image processing error
    JAM010X is detected twice.
  • Causes: Main/Engine PWB
  • Remedy: Replace the main/engine PWB.
  • Code: 0840
  • Description: Faults of RTC
    (“Time for maintenance T” is displayed) [Check at power up] The RTC setting has reverted to a previous state. The machine has not been powered for 5 years (compared to the settings stored periodically in the EEPROM). The RTC setting is older than 00:01 on January 1, 2000. [Checked periodically (in 5- minute interval) after powered up] The RTC setting has reverted to a state older than the last time it was checked. 10 minutes have been passed since the previous check.
  • Causes: Battery ( main PWB). Main/Engine PWB.
  • Remedy: Battery ( main PWB) 1. Make sure that the back-up batteries on the main/engine PWB are not shortcircuited. 2. Reset Maintenance T by executing U906. 3. If the same C call is displayed when power is switched on and off, replace the back up battery. 4. If communication error (due to a noise, etc.) is present with the RTC on the main/engine PWB, check the PWB is properly grounded.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 1810
  • Description: Paper feeder unit 2 communication error
    A communication error from paper feeder is detected 10 times in succession.
  • Causes: Paper feeder. PF main PWB. Main/Engine PWB.
  • Remedy: Paper feeder Check the wiring connection status with the main unit and, if necessary, try connecting it again.
    PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC1) and main/engine PWB (YC18) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PFMain/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB. main PWB.
  • Code: 1820
  • Description: Paper feeder unit 3 communication error
    A communication error from paper feeder is detected 10 times in succession.
  • Causes: Paper feeder. PF main PWB. Main/Engine PWB
  • Remedy: Paper feeder Check the wiring connection status with paper feeder unit 2 and, if necessary, try connecting it again.
    PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC1) and PF main PWB (YC2). 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 1830
  • Description: Paper feeder unit 4 communication error
    A communication error from paper feeder is detected 10 times in succession.
  • Causes: Paper feeder. PF main PWB. Main/Engine PWB.
  • Remedy: Paper feeder Check the wiring connection status with paper feeder unit 3 and, if necessary, try connecting it again.
    PF main PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF main PWB (YC1) and PF main PWB (YC2). 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the PF main PWB.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 1900
  • Description: Paper feeder unit 2 EEPROM error
    When writing the data, read and write data does not match 4 times in succession.
  • Causes: PF main PWB (EEPROM)
  • Remedy: 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB.
  • Code: 1910
  • Description: Paper feeder unit 3 EEPROM error
    When writing the data, read and write data does not match 4 times in succession.
  • Causes: PF main PWB (EEPROM)
  • Remedy: 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB.
  • Code: 1920
  • Description: Paper feeder unit 4 EEPROM error
    When writing the data, read and write data does not match 4 times in succession.
  • Causes: PF main PWB (EEPROM)
  • Remedy: 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. 2. Replace the PF main PWB.
  • Code: 2000
  • Description: Main motor steady-state error
    After main motor is stabilized, the ready signal is not ready for 1 s continuously.
  • Causes: Main motor. Main/Engine PWB.
  • Remedy: Main motor 1. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. main motor and main/engine PWB (YC4) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the main motor.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 2010
  • Description: Main motor startup error
    Main motor is not stabilized within 3 s since the motor is activated.
  • Causes: Main motor. Main/Engine PWB.
  • Remedy: Main motor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. main motor and main/engine PWB (YC4) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the main motor.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 3100
  • Description: Scanner carriage error
    The home position is not correct when the power is turned on, at the end of a reading process of the table and document processor.
  • Causes: Scanner motor. Home position sensor. Main/Engine PWB.
  • Remedy: Scanner motor 1. Move the scanner by the hand to check whether it is unusually difficult to move. 2. Check that the scanner driving belt is not disengaged. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Scanner motor and main/engine PWB (YC1) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the scanner motor.
    Home position sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Home position sensor and main/engine PWB (YC7) 3. Replace the home position sensor.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 3200
  • Description: Exposure lamp error
    When a lamp is made to turn on one side at a time, the white standard data at the time of an initial is lower than a rated value.
  • Causes: CIS. Main/Engine PWB.
  • Remedy: CIS Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. CIS and main/engine PWB (YC2011) Replace the image scanner unit.
    Main/Engine PWB Replace the main/engine PWB and check for correct operation.
  • Code: 3210
  • Description: CIS lamp error
    When a lamp is made both to turn on, the white standard data at the time of an initial is lower than a rated value
  • Causes: CIS. Main/Engine PWB.
  • Remedy: CIS 1. Execute U906 Separating Operation Release. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CIS and main/engine PWB (YC2011) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the CIS and execute U411.
    Main/Engine PWB Replace the main/engine PWB and check for correct operation.
  • Code: 3300
  • Description: Optical system (AGC) error One of the gains is FF or 00 during the CIS lamp AGC is being processed.
  • Causes: CIS. Main/Engine PWB.
  • Remedy: CIS 1. Execute U906 Separating Operation Release. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CIS and main/engine PWB (YC2011) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the CIS and execute U411.
    Main/Engine PWB Replace the main/engine PWB and check for correct operation.
  • Code: 3500
  • Description: Communication error between scanner and ASIC An error code is detected.
  • Causes: CIS. Main/Engine PWB.
  • Remedy: CIS 1. Execute U906 Separating Operation Release. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CIS and main/engine PWB (YC2011) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the CIS and execute U411.
    Main/Engine PWB Replace the main/engine PWB and check for correct operation.
  • Code: 3600
  • Description: Scanner sequence error
  • Causes: Main/Engine PWB.
  • Remedy: 1. Execute U021 memory initializing. 2. Replace the main/engine PWB and execute U411.
  • Code: 4000
  • Description: Polygon motor steady-state error
    After Polygon motor is stabilized, the ready signal is at the H level for 1 s continuously.
  • Causes: Polygon motor (LSU). Main/Engine PWB.
  • Remedy: Polygon motor (LSU) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Polygon motor and main/engine PWB (YC10) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the laser scanner unit.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 4010
  • Description: Polygon motor synchronization error
    After polygon motor is driven, the polygon motor speed won’t stabilize within 10 s.
  • Causes: Polygon motor (LSU). Main/Engine PWB.
  • Remedy: Polygon motor (LSU) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Polygon motor and main/engine PWB (YC10) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the laser scanner unit.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 4200
  • Description: BD steady-state error
    The BD signal is not detected.
  • Causes: APC PWB (LSU). Main/Engine PWB.
  • Remedy: APC PWB (LSU) 1. Confirm that the FCC wiring connector is not distorted and connect the FCC wiring all the way in. Laser scanner unit and main/engine PWB (YC2010) 2. If the FCC wiring is disconnected, shorted or grounded, replace the FCC wiring. 3. Replace the laser scanner unit.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 6000
  • Description: Broken fuser heater wire (main)
    When the fuser thermistor 1 reaches primary stable temperature after a warm-up start and the fuser thermistor 2 is less than 90 ° C/194 °F.
  • Causes: Fuser unit. Main/Engine PWB. Power source PWB. Fuser heater.
  • Remedy: Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and mmain/engine PWB (YC14) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit and execute U167 counter clear. (Deteriorated sensitivity due to the toner adhered to the center thermistor.)
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
    Power source PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Power source PWB (YC4) and main/ engine PWB (YC14) 2. Replace the power source PWB.
    Fuser heater 1. Replace the Fuser unit and execute U167 counter clear.
  • Code: 6020
  • Description: Abnormally high fuser thermistor 2 temperature (Center)
    Fuser thermistor 2 detects a temperature higher than 210°C/410°F.
  • Causes: Fuser unit. Main/Engine PWB.
  • Remedy: Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and main/engine PWB (YC14) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 6030
  • Description: Broken fuser thermistor 2 wire (Center)
    Input from fuser thermistor 2 is 1012 or more (A/D value) continuously for 5 s. Input from fuser thermistor 2 is1012 (A/D value) or more whenthe temperature at the fuser thermistor 1 is 70°C/ 158°F or more.
  • Causes: Fuser unit. Main/Engine PWB. Fuser thermistor 2. Fuser thermostat (triggered)
  • Remedy: Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and main/engine PWB (YC14) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit and execute U167 counter clear. (Deteriorated sensitivity due to the toner adhered to the center thermistor.)
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
    Fuser thermistor 2 1. Replace the Fuser unit and execute U167 counter clear.
    Fuser thermostat (triggered) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser heater PWB (YC1) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit and execute U167 counter clear.
  • Code: 6200
  • Description: Broken fuser heater wire (Sub)
    Fuser thermistor 1 does not reach primary stable temperature even after 30 s during warming up. Fuser thermistor 1 detects a temperature lower than 100°C/212°F for 60 s during ready.
  • Causes: Fuser unit. Main/Engine PWB. Fuser thermistor 1
  • Remedy: Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and main/engine PWB (YC14) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit and execute U167 counter clear.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
    Fuser thermistor 1 1. Replace the Fuser unit and execute U167 counter clear.
  • Code: 6220
  • Description: Abnormally high fuser thermistor 1 temperature (Edge)
    Fuser thermistor 1 detects a temperature higher than 230°C/446°F.
  • Causes: Fuser unit. Main/Engine PWB.
  • Remedy: Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and main/engine PWB (YC14) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit and execute U167 counter clear.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 6230
  • Description: Broken fuser thermistor 1 wire (Edge)
    Input from fuser thermistor 1 is 1012 or more (A/D value) continuously for 5 s. Input from fuser thermistor 1 is1012 (A/D value) or more whenthe temperature at the fuser thermistor 2 is 70°C/ 158°F or more.
  • Causes: Fuser unit. Main/Engine PWB.
  • Remedy: Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and main/engine PWB (YC14) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit and execute U167 counter clear.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 6400
  • Description: Zero-cross signal error
    While fuser heater ON/OFF control is performed, the zerocross signal is not input within 3 s.
  • Causes: Fuser unit.
  • Remedy: 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Power source PWB (CN2) and main/ engine PWB (YC14) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the power source PWB.
  • Code: 7100
  • Description: Toner sensor error
    Sensor output value of 8 or less.
  • Causes: Toner sensor. Toner motor. Main/Engine PWB.
  • Remedy: Toner sensor 1. Check the toner sensor output by U150. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner sensor and main/engine PWB (YC9) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Check that the gears of the Developer unit are not damaged and the spiral can rotate. 5. Replace the Developer unit.
    Toner motor 1. Draw out the toner container and execute U135 to check the toner motor operation. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Toner motor and main/engine PWB (YC12) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the Toner motor.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 7800
  • Description: Broken temperature sensor wire
    Input from temperature sensor is 0.3 V (A/D value) or less
  • Causes: Outer temperature sensor. Main/Engine PWB.
  • Remedy: Outer temperature sensor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Temperature sensor and main/engine PWB (YC6) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the temperature sensor.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 7810
  • Description: Short-circuited temperature sensor wire
    Input from temperature sensor is 0.3 V (A/D value) or more
  • Causes: Outer temperature sensor. Main/Engine PWB.
  • Remedy: Outer temperature sensor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Temperature sensor and main/engine PWB (YC6) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the temperature sensor.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 7900
  • Description: Drum EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively.
  • Causes: DR PWB. Main/Engine PWB.
  • Remedy: DR PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DR PWB and main/engine PWB (YC9) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Drum unit.
    Main/Engine PWB 1. Check the main/engine software and upgrade to the latest, if necessary. 2. Replace the main/engine PWB.
  • Code: 9000
  • Description: Document processor communication error
    A communication error from document processor is detected 10 times in succession.
  • Causes: DP main PWB.
  • Remedy: 1. Check that the versions of the main unit firmware and the DP firmware are identical. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP main PWB(YC1) and main/engine PWB (YC18) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the DP main PWB
  • Code: 9060
  • Description: DP EEPROM error
    Mismatch of reading data from two locations occurs 3 times successively. Mismatch between writing data and reading data occurs 3 times successively.
  • Causes: DP main PWB. Device damage of EEPROM.
  • Remedy: 1. Execute U906 Separating Operation Release. 2. Confirm that the EEPROM has been properly installed. 3. Replace the DP main PWB
    Device damage of EEPROM Contact the Service Support.
  • Code: F000
  • Description: Communication error between Main/Engine PWB and Operation PWB
  • Causes: Main/Engine PWB. Operation PWB.
  • Remedy: Main/Engine PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Check that the wirings and connetors between the main/engine PWB and the operation PWB are normal. Main/engine PWB (YC2010) and operation PWB (YC1) 3. Check that the DIMM memories in the main/engine PWB are well conducted and, if not, replace. 4. Execute U021initialize memory. 5. Replace the main/engine PWB.
    Operation PWB Replace the operation PWB.
  • Code: F020
  • Description: Main/Engine PWB RAM check sum error
  • Causes: Main memory (RAM)
  • Remedy: Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main/engine PWB.
  • Code: F040
  • Description: Communication error between Main/Engine PWB and Print engine
  • Causes: Main/Engine PWB
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Repair or replace the wire from the main/ engine PWB, that may be grounded. (Check short-circuit between 5V and 3.3V.) 3. Check the main/engine software and upgrade to the latest, if necessary. 4. If not corrected, replace the main/engine PWB.
  • Code: F050
  • Description: Print engine ROM checksum error
  • Causes: Main/Engine PWB
  • Remedy: 1. Turn the main power swtch off and after 5 seconds, then turn power on. 2. Confirm that the EEPROM has been properly installed. 3. Check the main/engine software and upgrade to the latest, if necessary. 4. If not corrected, Replace the main/ engine PWB.

Японская компания Kyocera производит высококачественные лазерные принтеры и МФУ для офисной печати. Их продукция одна из самых востребованных на сегодняшний день. Ведь печатающие устройства Kyocera характеризуются высокой надежностью, износостойкостью и большим сроком эксплуатации. Однако даже их изделия не являются вечными. Со временем принтеры Kyocera начинают сбоить.

К счастью, оргтехника Kyocera оснащена системой самодиагностики (так же, как и струйные принтеры Canon). Поэтому, в случае возникновения проблемы, устройство самостоятельно выявит уязвимое место и сообщит Вам об этом миганием соответствующего индикатора на панели управления либо кодом ошибки, выведенным на дисплей принтера.

Если Вы не являетесь мастером по обслуживанию принтеров и МФУ Kyocera, то, чтобы понять, о чем сообщает печатающее устройство, Вам потребуется расшифровать указанный им код. Для этого мы добавили в статью таблицу кодов ошибок лазерных принтеров Kyocera серии FS и не только.

код ошибки Kyocera решение проблемы

Код ошибки

Значение ошибки

Решение проблемы

E-0001 (E1)

Поврежден чип картриджа либо установлен неоригинальный картридж.

Замените установленный картридж оригинальной версией изделия. Если хотите сэкономить, тогда купите и установите новый чип на картридж или перепрошейте принтер Kyocera. Однако предварительно не помешает попробовать сбросить ошибку соответствующей комбинацией клавиш (как это сделать, читайте в статье «Сброс ошибки установки неоригинального картриджа в принтерах Kyocera»).

E-0002 (E2)

Регион использования картриджа и принтера не совпадают.

Замените чип или прошейте принтер Kyocera.

E-0003 (E3)

Заполнена память принтера или МФУ Kyocera.

Отпечатайте ранее отсканированные листы или очистите очередь печати нажатием кнопки Стоп/Сброс (ранее отсканированные листы также удалятся из памяти принтера, даже если они еще не были распечатаны).

E-0007 (E7)

Тонер-картридж Kyocera израсходовал ресурс красящего вещества.

Замените или заправьте картридж Kyocera (если используете совместимый или перезаправленный расходник, то после установки его в принтер не забудьте сбросить ошибку зажатием на 3-5 секунды кнопок [Ок] и [Сброс/Стоп]).

E-0008 (E8)

Открыта крышка принтера либо не работает датчик закрытия крышек устройства.

Откройте и еще раз закройте переднюю и заднюю крышку принтера. Во время закрытия Вы должны услышать характерный щелчок. Если не помогло, то причина в неисправности датчика.

E-0009 (E9)

Лоток приема бумаги полон.

Уберите все отпечатанные листы бумаги из выходящего лотка. Чтобы возобновить печать, нажмите кнопку [Старт].

E-0012 (E12)

Ошибка памяти принтера Kyocera.

Попробуйте уменьшить разрешение печати. Скорее всего, формат создаваемого отпечатка не соответствует возможностям принтера.

E-0014 (E14)

Установлен неверный формат бумаги (неподдерживаемый принтером Kyocera).

Поменяйте бумагу на поддерживаемую принтером либо смените ее формат в настройках печати. Попробуйте обновить программное обеспечение. Возможно, это расширит поддерживаемые принтером Kyocera форматы.

E-0015 (E15)

Устройство не подключено к электрической сети либо на компьютере нет (не работает) драйвера принтера Kyocera.

Проверьте подключение печатающего аппарата к электрической сети, а также целостность кабеля. Если ошибка не исчезает, скачайте драйвер принтера Kyocera и установите его на компьютер.

E-0017 (E17)

Ошибка передачи данных.

Проверьте подключение принтера к компьютеру. Кабель не должен быть длиннее 5 метров, а также обязан поддерживать стандарт USB 2.0. Кроме того, переустановите драйвер принтера и утилиту Kyocera Client Tool.

E-0018 (E18)

Очередь печати заполнена.

Очистите очередь печати нажатием кнопки [Сброс] либо через драйвер принтера.

E-0019 (E19)

Неверный формат печати.

Отмените печать нажатием кнопки [Стоп/Сброс]. Выберите в настройках принтера соответствующий режим печати, а также установите в лоток поддерживаемый принтером формат бумаги.

J-0000 (jam0000)

Замятие бумаги за задней крышкой.

Откройте крышку и извлеките бумагу. Проверьте надежность крепления бумаги в лотке, а также принтер на наличие посторонних предметов. Еще причина может быть в пружине выходного флажка. Если она растянулась, то может плохо работать фиксатор. Также проблема может быть из-за печки, сделайте ее ревизию, переборку и смазку.

J-0501 (jam0501)

Бумага застряла в принтере Kyocera

Извлеките замятую бумагу. Проверьте надежность установки бумаги во входной лоток. Проверьте целостность роликов протяжки бумаги, а также принтер на наличие посторонних предметов. Если не помогло, стоит внимательно осмотреть ребра на направляющей пластине. На них могут образоваться сколы, трещины и заусенцы. Их можно слегка подчистить наждачной бумагой (нулевкой).

J-0511 (jam0511)

Принтер Kyocera замял бумагу.

Извлеките замятую бумагу и повторите печать. Если проблема не исчезла, несите принтер в сервис. Скорее всего, изношен ролик протяжки бумаги.

C7990

Бункер драм-картриджа (блока фотобарабана) заполнен отработанным тонером либо неисправен счетчик отработки красящего вещества. Еще проблема может быть в главной плате PWB.

Осуществите чистку драм-картриджа (блока фотобарабана). Если проблема в датчике или плате, то нужно отнести принтер в СЦ на диагностику.

F248

Ошибка обработки отпечатываемого материала.

Перезагрузите принтер. Уберите неподдерживаемые спецсимволы из отпечатка. Обновите ПО принтера Kyocera. Смените режим работы принтера с PDL на GDI (Пуск -> Принтеры -> Свойства -> Параметры устройства).

PF

Отсутствует бумага в лотке подачи.

Загрузите листы бумаги во входной лоток. Если принтер по-прежнему не печатает, значит нужно искать проблему в чем-то другом.

1101

Ошибка сканирования через сеть из-за неправильного имени SMTP сервера.

Пропишите DNS-адреса помимо прочих настроек печати по сети.

1102

Некорректная настройка сканера для работы через сеть

Зайдите в Web-панель управления принтером (нужно в адресную строку браузера ввести iP принтера Kyocera). Далее в зависимости от модели введите логин и пароль (Admin/Admin или просто admin00 без логина). Далее следуйте инструкции:

  • Откройте вкладку «Сканер» и установите настройки по умолчанию;
  • Перейдите на вкладку «Основные», выберите адресную книгу и нажмите добавить контакт;
  • В открывшемся окне найдите блок SMB и введите: имя хоста = имя компьютера или его iP-адрес, путь = название сетевой папки (если не расшарена, то вместе с ИП-адресом), имя пользователя = user или domainuser (в зависимости от типа профиля), пароль = пароль.

Логин и пароль нужны обязательно, если их нет, то следует создать.

2101

Ошибка передачи данных при сканировании через сеть.

Правильно настройте параметры (как для ошибки 1102), только предварительно отключите на ПК антивирус и брандмауэр.

Если Вы испытали все способы, но не смогли убрать ошибку, то следует нести печатающее устройство в сервисный центр. Кроме того, есть ряд ошибок (высвечиваемых на дисплее принтера), которые нельзя устранить в домашних условиях. Соответствующие коды ошибок принтеров Kyocera представляем в очередной таблице.

Коды ошибок принтеров и МФУ Kyocera, которые нужно устранять в сервисном центре

Код ошибки

Значение ошибки

Решение проблемы

0030

Неисправность платы управления факсом принтера.

Замена платы.

0100

Неисправность платы управления или флеш-памяти принтера.

Замена платы.

0120

Ошибка чтения mac-адреса из-за неисправности флеш-памяти принтера.

Замена платы.

0190

Неисправность платы управления или флеш-памяти принтера.

Замена платы.

0630

Неисправность платы управления принтера.

Замена платы.

1020

Неисправность мотора, привода или отсутствие контакта.

Разборка принтера и замена изношенных частей. Проверка надежности подключений, замена разорванных (прогоревших) кабелей. Ремонт или замена привода мотора.

1040

Неисправность мотора, привода или отсутствие контакта.

Разборка принтера и замена изношенных частей. Проверка надежности подключений, замена разорванных (прогоревших) кабелей. Ремонт или замена привода мотора.

2000

Неисправность главной платы управления, соединительного кабеля или привода принтера.

Проверить ремни, шестерни и ролики привода. Смазать или заменить, если есть дефекты. Заменить привод или главную плату.

3100 (C3100)

Неисправность главной платы, привода сканера, датчика положения или нарушение целостности соединений.

Проверить наличие разрывов и отсутствия контакта. Смазать или заменить изношенные элементы привода. Заменить привод, главную плату, датчик или соединительный кабель. Если Вам повезло, то возможно забыли отключить фиксатор блока сканера.

3101

Сетевой кабель не подсоединен, или нарушена работа концентратора. Еще может быть из-за наличия вирусов в системе или неправильно заданным параметрам сервера SMTP.

Проверить соединения, правильно настроить параметры сети.

3300

Неисправность главной платы, датчика CIS или соединительного кабеля.

Проверить контакты, заменить плату или датчик.

3500

Неисправность главной платы или нарушение соединения контактов.

Проверить контакты, заменить плату.

4000 (C4000)

Неисправность главной платы, привода сканера или нарушение соединений. Однако чаще всего ошибка лазера.

Проверить контакты, заменить плату или привод блока сканера. Почистить лазер, смазать ось полигон-мотора, либо полностью заменить блок лазера.

4200

Неисправность главной платы, блока сканера или датчика BD.

Отключить питание принтера на 30 минут. Если не помогло, то следует заменить привод сканера или главную плату принтера.

6000 (С6000)

Неисправность главной платы, термостата, печки или нарушение соединения контактов.

Проверить и поправить контакты. Заменить фьюзер. Ремонт или замена печки, термодатчика, термопредохранителя и т.д.

6020

Сгорание термистора или главной платы.

Замена термистора или главной платы.

6030

Неисправность главной платы, термостата или термистора. Возможно, причина в отсутствии контакта.

Проверить соединения. Заменить плату, термостат или термистор.

6400

Неисправность главной платы, отсутствие питания или контакта.

Заменить плату или источник питания.

F000

Неисправность главной платы или отсутствие контакта.

Проверить соединение ремня безопасности. Заменить ремень или плату управления.

F020

Неисправность элементов памяти принтера.

Перезагрузить принтер. Если ошибка не устранилась – заменить плату управления.

F040

Неисправность главной платы принтера.

Перезагрузить принтер. Если ошибка не устранилась – заменить плату управления.

F05D

Неисправность главной платы. Сбой программного оборудования привода. Проблемы с прошивкой принтера Kyocera.

Перезагрузить принтер. Если ошибка не устранилась – заменить плату управления. Перепрошить принтер Kyocera.

F245 F246 F247 F375

Принтер Kyocera заблокирован из-за проблемы, вызванной отказом источника питания.

Нужно перепрошить принтер специальной сервисной микропрограммой.

Обратите внимание: Если у печатающего устройства нет дисплея, то определить проблему можно по светодиодным индикаторам, встроенным в панель управления принтером. Например, у Kyocera Ecosys P2135D нужно сосчитать количество миганий индикаторов красного цвета и таким образом определить число, указывающее на ту или иную ошибку. В свою очередь, у модели Kyocera FS-1040 все зависит от темпа мигания светодиода с надписью «Внимание!» («Attention!»):

  • Мигает медленно – указывает на отсутствие бумаги в лотке или тонера в картридже.
  • Мигает быстро – оповещает о проблеме с памятью устройства, переполненном лотке или замятии бумаги, а также об использовании неоригинальных расходных материалов.
  • Горит постоянно – говорит о проблемах с картриджем или фотобарабаном либо указывает на открытые крышки принтера.

ошибки принтера Kyocera

Чтобы потребитель мог наверняка определить проблему, рекомендуем использовать утилиту Kyocera Client Tool, которая идет в комплекте с драйверами принтера.


Ваше Имя:


Ваш вопрос:


Внимание: HTML не поддерживается! Используйте обычный текст.


Оценка:


Плохо
 

 

Хорошо


Введите код, указанный на картинке:


Понравилась статья? Поделить с друзьями:
  • Ошибка 7144 фольксваген туарег
  • Ошибка 71 тойота 3ct
  • Ошибка 71 реле возвратного насоса
  • Ошибка 710 принтер hp laserjet
  • Ошибка 71233 при смене пароля