Ошибка 7004 куосера

Code

Contents

7004

Toner motor Y error

When the toner motor Y is

driven, the motor over-current

detection signal is detected

continuously for 50 times (5 s)

at 100 ms intervals.

7401

Developing unit K non-

installing error

No density detection signal is

output from toner sensor K in

developing unit K.

7402

Developing unit C non-

installing error

No density detection signal is

output from toner sensor C in

developing unit C.

7403

Developing unit M non-

installing error

No density detection signal is

output from toner sensor M in

developing unit M.

Causes

Defective connec-

Reinsert the connector. Also check for conti-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

nector.

Toner motor Y and engine PWB (YC26)

Defective drive

Check if the rollers and gears rotate

transmission sys-

smoothly. If not, grease the bushes and

tem of the toner

gears. Check for broken gears and replace if

motor Y.

any.

Defective toner

Replace the toner motor Y.

motor Y.

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

Reinsert the connector. Also check for conti-

Defective connec-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

nector.

Developing unit K and Drum relay PWB

(YC6)

Drum relay PWB (YC1) and engine PWB

(YC34)

Defective toner

Replace the developing unit K (see page 1-

sensor K.

5-18).

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

Defective connec-

Reinsert the connector. Also check for conti-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

Developing unit C and Drum relay PWB

nector.

(YC10)

Drum relay PWB (YC1) and engine PWB

(YC34)

Defective toner

Replace the developing unit C (see page 1-

sensor C.

5-18).

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

Defective connec-

Reinsert the connector. Also check for conti-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

nector.

Developing unit M and Drum relay PWB

(YC7)

Drum relay PWB (YC1) and engine PWB

(YC34)

Defective toner

Replace the developing unit M (see page 1-

sensor M.

5-18).

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

1-4-25

Check procedures/

corrective measures

2KT/2KV

  • Code: C0030
  • Description: FAX PWB system error
  • Causes: The FAX processing cannot be continued due to the firmware error.
  • Remedy: 1 Reinstalling the firmware The firmware is faulty. Reinstall the firmware.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • FAX PWB — Main/engine PWB
    3 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB.
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C0070
  • Description: FAX PWB incompatible detection error
  • Causes: Abnormal detection of FAX control PWB incompatibility in the initial communication with the FAX control PWB, any normal communication command is not transmitted.
  • Remedy: 1 Checking the FAX PWB The incompatible FAX PWB is installed. Install the FAX PWB for the applicable model.
    2 Reinstalling the firmware The firmware is faulty. Reinstall the firmware.
  • Code: C0100
  • Description: Backup memory device error
  • Causes: The abnormal status is output from the flash memory.
  • Remedy: 1 Resetting the main power The EEPROM does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Reinstalling the EEPROM The EEPROM is not properly attached. Reattach the EEPROM on the main/engine PWB.
    3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004 when C0180 appears
    4 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0120
  • Description: MAC address data error
  • Causes: MAC address data was incorrect data.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Main/engine PWB replacement The MAC address is incorrect. Replace the main/engine PWB when the MAC address is not indicated on the network status page.
  • Code: C0130
  • Description: Backup memory reading/writing error
  • Causes: The reading or writing into the flash memory is unavailable.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0140
  • Description: Backup memory data error
  • Causes: The data read from the flash memory is judged as abnormal at the startup.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Executing U021 The flash memory does not operate properly. Execute U021.
    3 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0150
  • Description: EEPROM writing / reading error
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Reinstalling the EEPROM The EEPROM is not properly attached. Reattach the EEPROM on the main/engine PWB.
    3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004.
    4 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0160
  • Description: EEPROM data error
  • Causes: The data read from the EEPROM is judged as abnormal.
  • Remedy: 1 Resetting the main power The EEPROM does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Executing U021 The data stored in the EEPROM on the main/ engine PWB is faulty. Execute U021.
    3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004.
  • Code: C0170
  • Description: Charger count error
  • Causes: The values in one of the billing counters, life counter or the scanner counter mismatch between the main side and the engine side.
  • Remedy: 1 Reinstalling the EEPROM The EEPROM for the different main unit is installed. Execute U004 to check machine serial number at MAIN and ENGINE. If different numbers are displayed, attach the proper EEPROM to the main/engine PWB
    2 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004 when C0180 appears
    3 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0180
  • Description: Machine serial number mismatch
  • Causes: The machine serial Nos. in the main PWB and the EEPROM on the engine PWB mismatch when turning the power on.
  • Remedy: 1 Reinstalling the EEPROM The EEPROM for the different main unit is installed. Execute U004 to check machine serial number at MAIN and ENGINE. If different numbers are displayed, attach the proper EEPROM to the main/engine PWB
    2 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the main/engine PWB and execute U004 when C0180 appears
  • Code: C0190
  • Description: Backup memory device error
  • Causes: Data from the FRAM cannot be read at start-up (3 times retries)
  • Remedy: 1 Resetting the main power FRAM (main/engine PWB) is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0360
  • Description: Communication error between the engine PWB and ASIC
  • Causes: The checksum error appears or the video signal is not reversed when checking the read-back data after transmitting the data. (Successive failure 10 times)
  • Remedy: 1 Resetting the main power The main/engine PWB does not operate correctly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the engine relay PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the engine relay PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the engine relay PWB.
    3 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0640
  • Description: Hard Disk (SSD) error
  • Causes: The SSD I/O error is detected when accessing the file after the ready mode. (SSD format error after restart such as the system initialization, Sanitization or encrypted format after introducing the security kit)
  • Remedy: 1 Resetting the main power The main/engine PWB does not operate correctly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Reinstalling HD-6/7 (SSD) The HD-6/7 (SSD) is not connected to the KUIO connector of the main/ engine PWB Turn the power switch off and disconnect the power cord. Check the HD-6/7 (SSD) is connected to the KUIO connector of the main/engine PWB properly and reinstalled the HD-6/7 (SSD).
    3 Initializing HD-6/7 (SSD) HD-6 or HD-7 (SSD) does not operate correctly. Initialize the HD-6/7 (SSD) at [System Menu/Counter] key > [Adjustment/Maintenance] > [Service Settings] > [SSD Format].
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C0800
  • Description: Image processing error
  • Causes: The print sequence jam (J010x) is detected 2 times in succession.
  • Remedy: 1 Checking the image data The image data is faulty. When this issue occurs only when handling the certain image data, check if the image data is faulty.
    2 Checking the situation The printing operation of the certain file is faulty. Acquire the job’s log if the phenomenon can be reproduced by specifying the job when the error was detected.
    3 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0830
  • Description: FAX PWB flash program area checksum error
  • Causes: The program stored in the flash memory is broken so it cannot perform.
  • Remedy: 1 Reinstalling the firmware The firmware is faulty. Reinstall the firmware.
    2 Initializing the fax The FAX data is faulty. Execute U600 to initialize the FAX.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • FAX PWB — Main/engine PWB
    4 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB.
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C0840
  • Description: RTC error (‘Time for maintenance T’ appears)
  • Causes: [Check at start-up] • RTC values are old. • Power has not been turned on for over 5 years. • RTC value is older than 2000/1/1 00:01. [Periodic check per 5 minutes after start-up] • RTC values are older than the ones at the last check. • Partial operation by power reset after C840 error and ‘Time for Maintenance T’ is indicated.
  • Remedy: 1 Setting the RTC RTC is not properly set. Set the RTC in the System Menu.
    2 Checking the life of the backup battery The backup battery has run out. If the same service call error appears after resetting the power, check the backup battery. If it has run out, replace the backup battery on the main/engine PWB.
    3 Reattaching the main/ engine PWB The main/engine PWB is not properly attached. Retighten the screws for the main/engine PWB.
    4 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C0870
  • Description: Image data transmission error to FAX PWB
  • Causes: Data was not properly transmitted even if the specified times of retry were made when the large volume data is transmitted into the FAX PWB
  • Remedy: 1 Reinstalling the firmware The firmware is faulty. Reinstall the firmware.
    2 Initializing the fax The FAX data is faulty. Execute U600 to initialize the FAX.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • FAX PWB — Main/engine PWB
    4 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB.
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C0920
  • Description: FAX file system error
  • Causes: The backup data cannot be stored in the flash memory device due to the file system error
  • Remedy: 1 Reinstalling the firmware The firmware is faulty. Reinstall the firmware.
    2 Initializing the fax The FAX data is faulty. Execute U600 to initialize the FAX.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • FAX PWB — Main/engine PWB
    4 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB.
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C1010
  • Description: Lift motor error
  • Causes: After installing cassette 1, either of the following 1 to 4 is detected 5 times continuously. 1. The lift motor excess current is detected for 80ms. 2. The lift sensor does not turn on when passing 10s after installing the cassette. 3. During printing, after detecting the lift sensor off, the lift sensor does not turn on when passing 1s after the ascending control. 4. During motor operation, the lock signal is detected for 1s continuously and it is detected 5 times continuously.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. If the lift plate does not ascend or descend, correct it or replace it.
    2 Checking the drive gear The drive gear does not rotate properly. Check if MP lift plate elevation drive gears rotate or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that they can rotate properly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Lift sensor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking the lift motor The lift motor is not properly attached, or it is faulty. Reattach the lift motor. If it is not repaired, replace it.
    5 Checking the lift sensor The lift sensor is not properly attached, or it is faulty. Reattach PF lift upper limit sensor. If not repaired, replace it.
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    8 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C1020
  • Description: PF lift motor 1 error
  • Causes: Target: Paper feeder (1st) After installing the cassette, either of the following 1 to 3 is detected 5 times continuously. 1. The PF lift motor excess current is detected for 80ms. 2. The PF lift sensor does not turn on when passing 10s after installing the cassette. 3. During printing, after detecting the PF lift sensor off, the PF lift sensor does not turn on when passing 1s after the ascending control.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. If the lift plate does not ascend or descend, correct it or replace it.
    2 Checking the drive gear The drive gear does not rotate properly. Check if MP lift plate elevation drive gears rotate or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that they can rotate properly.
    3 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    4 Checking the connection The connector is not connected properly or, the wire or drawer connector is faulty. Check the following wire connection, and correct the terminals and reconnect the connectors all the way. If the wire has no continuity or the drawer connector is faulty, replace them.• PF lift sensor — PF PWB• PF lift motor — PF PWB• PF PWB — Drawer connector• Drawer connector — PF PWB (2nd paper feeder)
    5 Checking the PF lift motor PF lift motor is not attached properly or faulty. Reattach the PF lift motor. If it is not repaired, replace it.
    6 Checking the PF lift sensor The PF lift motor is not properly attached, or it is faulty. Reattach the PF lift sensor. If it is not repaired, replace it.
    7 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
    8 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    9 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
  • Code: C1030
  • Description: PF lift motor 2 error
  • Causes: Target: Paper feeder (2nd) After installing the cassette, either of the following 1 to 3 is detected 5 times continuously. 1. The PF lift motor excess current is detected for 80ms. 2. The PF lift sensor does not turn on when passing 10s after installing the cassette. 3. During printing, after detecting the PF lift sensor off, the PF lift sensor does not turn on when passing 1s after the ascending control.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. If the lift plate does not ascend or descend, correct it or replace it.
    2 Checking the drive gear The drive gear does not rotate properly. Check if MP lift plate elevation drive gears rotate or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that they can rotate properly.
    3 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    3 Checking the connection The connector is not connected properly or, the wire or drawer connector is faulty. Check the following wire connection, and correct the terminals and reconnect the connectors all the way. If the wire has no continuity or the drawer connector is faulty, replace them.• PF lift sensor — PF PWB• PF lift motor — PF PWB• PF PWB — Drawer connector• Drawer connector — PF PWB (2nd paper feeder)
    4 Checking the PF lift motor PF lift motor is not attached properly or faulty. Reattach the PF lift motor. If it is not repaired, replace it.
    5 Checking the PF lift sensor The PF lift motor is not properly attached, or it is faulty. Reattach the PF lift sensor. If it is not repaired, replace it.
    6 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C1040
  • Description: PF lift motor 3 error
  • Causes: Target: Paper feeder (3rd) After installing the cassette, either of the following 1 to 3 is detected 5 times continuously. 1. The PF lift motor excess current is detected for 80ms. 2. The PF lift sensor does not turn on when passing 10s after installing the cassette. 3. During printing, after detecting the PF lift sensor off, the PF lift sensor does not turn on when passing 1s after the ascending control.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. If the lift plate does not ascend or descend, correct it or replace it.
    2 Checking the drive gear The drive gear does not rotate properly. Check if MP lift plate elevation drive gears rotate or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that they can rotate properly.
    3 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    4 Checking the connection The connector is not connected properly or, the wire or drawer connector is faulty. Check the following wire connection, and correct the terminals and reconnect the connectors all the way. If the wire has no continuity or the drawer connector is faulty, replace them.• PF lift sensor — PF PWB• PF lift motor — PF PWB• PF PWB — Drawer connector• Drawer connector — PF PWB (2nd paper feeder)
    5 Checking the PF lift motor PF lift motor is not attached properly or faulty. Reattach the PF lift motor. If it is not repaired, replace it.
    6 Checking the PF lift sensor The PF lift motor is not properly attached, or it is faulty. Reattach the PF lift sensor. If it is not repaired, replace it.
    7 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C1810
  • Description: Paper Feeder communication error
  • Causes: Target: Paper feeder (1st) The communication error was detected 10 times continuously.
  • Remedy: 1 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    2 Checking the connection The connector is not connected properly or, the wire or drawer connector is faulty. Check the following wire connection, and correct the terminals and reconnect the connectors all the way. If the wire has no continuity or the drawer connector is faulty, replace them.• PF lift sensor — PF PWB• PF lift motor — PF PWB• PF PWB — Drawer connector• Drawer connector — PF PWB (2nd paper feeder)
    3 Firmware upgrade The firmware is not the latest version. Upgrade the firmware to the latest version.
    4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
    5 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
  • Code: C1820
  • Description: Paper feeder communication error
  • Causes: Target: Paper feeder (2nd) The communication error was detected 10 times continuously.
  • Remedy: 1 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    2 Checking the connection The connector is not connected properly or, the wire or drawer connector is faulty. Check the following wire connection, and correct the terminals and reconnect the connectors all the way. If the wire has no continuity or the drawer connector is faulty, replace them.• PF lift sensor — PF PWB• PF lift motor — PF PWB• PF PWB — Drawer connector• Drawer connector — PF PWB (2nd paper feeder)
    3 Firmware upgrade The firmware is not the latest version. Upgrade the firmware to the latest version.
    4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
    5 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB in the 1st paper feeder.
  • Code: C1830
  • Description: Paper feeder communication error
  • Causes: Target: Paper feeder (3rd) The communication error was detected 10 times continuously.
  • Remedy: 1 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    2 Checking the connection The connector is not connected properly or, the wire or drawer connector is faulty. Check the following wire connection, and correct the terminals and reconnect the connectors all the way. If the wire has no continuity or the drawer connector is faulty, replace them.• PF lift sensor — PF PWB• PF lift motor — PF PWB• PF PWB — Drawer connector• Drawer connector — PF PWB (2nd paper feeder)
    3 Firmware upgrade The firmware is not the latest version. Upgrade the firmware to the latest version.
    4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
    5 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB in the 2nd paper feeder.
  • Code: C1900
  • Description: Paper Feeder EEPROM error
  • Causes: Target: Paper feeder (1st) For the internal count The writing data and the reading data mismatch 4 times continuously when writing.
  • Remedy: 1 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert the connectors into all the connectors on the PF PWB. Also, if there is no continuity, replace the wire.
    3 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C1910
  • Description: Paper feeder EEPROM error
  • Causes: Target: Paper feeder (2nd) For the internal count The writing data and the reading data mismatch 4 times continuously when writing.
  • Remedy: 1 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert the connectors into all the connectors on the PF PWB. Also, if there is no continuity, replace the wire.
    3 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C1920
  • Description: Paper feeder EEPROM error
  • Causes: Target: Paper feeder (3rd) For the internal count The writing data and the reading data mismatch 4 times continuously when writing.
  • Remedy: 1 Reinstalling the paper feeder The paper feeder is not properly installed. Reinstall the paper feeder
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert the connectors into all the connectors on the PF PWB. Also, if there is no continuity, replace the wire.
    3 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C2101
  • Description: Developer motor steady state error
  • Causes: The steady signal turns off for 2s continuously after the motor is stabilized.
  • Remedy: 1 Checking the developer unit The developer roller is faulty. Replace developer unit C, M or Y if the developer roller does not rotate.
    2 Checking the driving parts The developer motor drive is not transmitted correctly. Check if the drive gear rotates smoothly and has no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Developer motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking the developer motor The developer motor is not properly attached, or it is faulty. Reattach the developer motor. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2111
  • Description: Developer motor start-up error
  • Causes: The steady signal does not turn on after passing 3s since the motor started up
  • Remedy: 1 Checking the developer unit The developer roller is faulty. Replace developer unit C, M or Y if the developer roller does not rotate.
    2 Checking the driving parts The developer motor drive is not transmitted correctly. Check if the drive gear rotates smoothly and has no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Developer motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking the developer motor The developer motor is not properly attached, or it is faulty. Reattach the developer motor. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2201
  • Description: Drum motor 2 steady-state error
  • Causes: The steady signal turns off for 2s continuously after the motor is stabilized.
  • Remedy: 1 Checking the drum unit and the developer unit The drum does not rotate smoothly. Check if the drum and the drum cleaning screw rotates manually. If it locks up, replace drum unit C or Y.
    2 Checking the driving parts The drum motor 2 drive is not transmitted correctly. Check if the drive gear rotates smoothly and has no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Drum motor 2 — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking drum motor 2 Drum motor 2 is not properly attached, or it is faulty. Reattach drum motor 2. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2202
  • Description: Drum motor 1 steady-state error
  • Causes: The steady signal turns off for 2s continuously after the motor is stabilized.
  • Remedy: 1 Checking the drum unit and the developer unit The drum does not rotate smoothly. Check if the drum and the drum cleaning screw rotates manually. If it locks up, replace drum unit K or M.
    2 Checking the driving parts The drum motor 1 drive is not transmitted correctly. Check if the drive gear rotates smoothly and has no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Drum motor 1 — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking drum motor 1 Drum motor 1 is not properly attached, or it is faulty. Reattach drum motor 1. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2211
  • Description: Drum motor 2 standby error
  • Causes: The steady signal does not turn on after passing 3s since the motor started up
  • Remedy: 1 Checking the drum unit and the developer unit The drum does not rotate smoothly. Check if the drum and the drum cleaning screw rotates manually. If it locks up, replace drum unit C or Y.
    2 Checking the driving parts The drum motor 2 drive is not transmitted correctly. Check if the drive gear rotates smoothly and has no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Drum motor 2 — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking drum motor 2 Drum motor 2 is not properly attached, or it is faulty. Reattach drum motor 2. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2212
  • Description: Drum motor 1 standby error
  • Causes: The steady signal does not turn on after passing 3s since the motor started up
  • Remedy: 1 Checking the drum unit and the developer unit The drum does not rotate smoothly. Check if the drum and the drum cleaning screw rotates manually. If it locks up, replace drum unit K or M.
    2 Checking the driving parts The drum motor 1 drive is not transmitted correctly. Check if the drive gear rotates smoothly and has no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Drum motor 1 — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking drum motor 1 Drum motor 1 is not properly attached, or it is faulty. Reattach drum motor 1. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2500
  • Description: Conveying developer motor error
  • Causes: The steady signal does not turn on after passing 3s since the motor started up or the steady signal turns off for 2s continuously after the motor is stabilized
  • Remedy: 1 Checking the driving parts The conveying developer motor drive is not transmitted correctly. Check if the paper conveying roller and the drive gear rotate smoothly and have no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates smoothly.
    2 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Conveying developer motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB • LSU — Main/engine PWB
    3 Checking the conveying developer motor The conveying developer motor is not properly attached, or it is faulty. Reattach the conveying developer motor. If it is not repaired, replace it.
    4 Replacing the conveying drive unit The conveying drive unit is faulty. Replace the conveying drive unit.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2600
  • Description: PF feed motor error
  • Causes: Target: Paper feeder (1st) The steady signal does not turn on for 5s continuously when the motor drives
  • Remedy: 1 Checking the driving parts The PF feed motor drive is not transmitted correctly. Check if the PF feed roller or the drive gear rotates or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates properly.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF feed motor — PF PWB
    3 Checking the PF feed motor The PF feed motor is not properly attached, or it is faulty. Reattach the PF feed motor. If it is not repaired, replace it.
    4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C2610
  • Description: PF feed motor error
  • Causes: Target: Paper feeder (2nd) The steady signal does not turn on for 5s continuously when the motor drives
  • Remedy: 1 Checking the driving parts The PF feed motor drive is not transmitted correctly. Check if the PF feed roller or the drive gear rotates or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates properly.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF feed motor — PF PWB
    3 Checking the PF feed motor The PF feed motor is not properly attached, or it is faulty. Reattach the PF feed motor. If it is not repaired, replace it.
    4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C2620
  • Description: PF feed motor error
  • Causes: Target: Paper feeder (3rd) The steady signal does not turn on for 5s continuously when the motor drives
  • Remedy: 1 Checking the driving parts The PF feed motor drive is not transmitted correctly. Check if the PF feed roller or the drive gear rotates or have no excessive load. And apply the grease to the frictional parts and repair the related parts so that the drive gear rotates properly.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF feed motor — PF PWB
    3 Checking the PF feed motor The PF feed motor is not properly attached, or it is faulty. Reattach the PF feed motor. If it is not repaired, replace it.
    4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C2760
  • Description: Primary transfer motor startup error
  • Causes: The steady signal does not turn on after passing 3s since the motor started up
  • Remedy: 1 Checking the driving parts The primary transfer motor drive is not transmitted correctly. Check if the excessive load is given by rotating the drive gears, roller and the transfer belt, and clean the drive section for the primary transfer unit.
    2 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Primary transfer motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    3 Checking the primary transfer motor The primary transfer motor is not properly attached, or it is faulty. Reattach the primary transfer motor. If it is not repaired, replace it.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C2820
  • Description: Primary transfer motor steady-state error
  • Causes: The steady signal turns off for 2s continuously after the motor is stabilized.
  • Remedy: 1 Checking the driving parts The primary transfer motor drive is not transmitted correctly. Check if the excessive load is given by rotating the drive gears, roller and the transfer belt, and clean the drive section for the primary transfer unit.
    2 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Primary transfer motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    3 Checking the primary transfer motor The primary transfer motor is not properly attached, or it is faulty. Reattach the primary transfer motor. If it is not repaired, replace it.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C3100
  • Description: Scanner carriage error
  • Causes: The home position is not correct when the power is turned on or at the end of a reading process of the table or document processor.
  • Remedy: 1 Checking the scanner carriage A load is applied to the scanner movement. If there is an excessive load when manually operating the scanner carriage, check if foreign objects is on the drive belt. Then, clean the drive belt and after that, apply the grease to the ISU shaft.
    2 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Scanner motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    3 Checking the home position sensor The home position sensor is not properly attached, or it is faulty. Reattach the home position sensor. If it is not repaired, replace it.
    4 Checking the scanner motor The scanner motor is not attached properly or faulty. Reattach the scanner motor. If it is not repaired, replace it.
    5 Replacing the scanner carriage The CCD PWB is faulty. Replace the scanner carriage.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C3200
  • Description: LED lamp error
  • Causes: The white reference data retrieved by lighting the lamp at the initial operation is at the specified value or less.
  • Remedy: 1 Checking the connection FFC is not properly connected, or it is faulty. Clean the following FFC terminal of the FFC and reconnect. If the FFC terminal is deformed or FFC is short circuited, replace FFC. • CCD PWB — Main/engine PWB
    2 Replacing the scanner carriage The LED is faulty if the LED lamp does not turn on. Or, the CCD PWB is faulty. Replace the scanner carriage.
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C3210
  • Description: CIS lamp error
  • Causes: Target: Dual scan DP (For 35ppm model) The white reference data obtained by turning the lamp on at initialization is less than the specified value.
  • Remedy: 1 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • DPCIS — DPCIS relay PWB • DPCIS relay PWB — Main/ Engine PWB
    2 (When the CIS lamp does not turn on) Replacing the DPCIS The DPCIS is faulty. Replace the DPCIS.
    3 (When the CIS lamp does not turn on) Replacing the DPCIS relay PWB The DPCIS relay PWB is faulty. Replace the DPCIS relay PWB.
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C3500
  • Description: Communication error between the scanner and ASIC
  • Causes: The communication error was detected during communication
  • Remedy: 1 Checking the connection FFC is not properly connected, or it is faulty. Clean the following FFC terminal of the FFC and reconnect. If the FFC terminal is deformed or FFC is short circuited, replace FFC. • CCD PWB — Main/engine PWB
    2 Replacing the scanner carriage The CCD PWB is faulty. Replace the scanner carriage.
    3 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4001
  • Description: Polygon motor KM startup error
  • Causes: The steady signal of the motor does not turn on after passing 6s since the polygon motor starts up
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4002
  • Description: Polygon motor CY startup error
  • Causes: The steady signal of the motor does not turn on after passing 6s since the polygon motor starts up
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4011
  • Description: Polygon motor KM stabilization error
  • Causes: The steady signal of the motor turns off for 6s in succession after the polygon motor was stabilized
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4012
  • Description: Polygon motor CY stabilization error
  • Causes: The steady signal of the motor turns off for 6s in succession after the polygon motor was stabilized
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4101
  • Description: Laser error (Black)
  • Causes: The laser is not received for 1s since the light emission of the laser (Black) was started.
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4102
  • Description: Laser error (Cyan)
  • Causes: The laser is not received for 1s since the light emission of the laser (Cyan) was started.
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4103
  • Description: Laser error (Magenta)
  • Causes: The laser is not received for 1s since the light emission of the laser (Magenta) was started.
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4104
  • Description: Laser error (Yellow)
  • Causes: The laser is not received for 1s since the light emission of the laser (Yellow) was started.
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4201
  • Description: Laser BD steady-state error (Black)
  • Causes: The black BD signal is not detected during the polygon motor steady rotation
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4202
  • Description: Laser BD steady-state error (Cyan)
  • Causes: The black Cyan signal is not detected during the polygon motor steady rotation
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4203
  • Description: Laser BD steady-state error (Magenta)
  • Causes: The black Magenta signal is not detected during the polygon motor steady rotation
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4204
  • Description: Laser BD steady-state error (Yellow)
  • Causes: The Yellow Magenta signal is not detected during the polygon motor steady rotation
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is faulty. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4600
  • Description: LSU cleaning motor error
  • Causes: Excess current was detected for 5s continuously during the LSU cleaning motor operation
  • Remedy: 1 Executing the Laser Scanner Cleaning The LSU cleaning drive gear or the cleaning spiral does not smoothly rotate due to the load. Execute Laser Scanner Cleaning.
    2 Cleaning the LSU The LSU cleaning drive gear or the cleaning spiral does not smoothly rotate due to the load. Clean the LSU cleaning drive gear and the cleaning spiral, and then apply grease to these parts.
    3 LSU replacement The LSU cleaning drive gear or the cleaning spiral is deformed or there is a fault in them. Replace the LSU.
    4 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU cleaning motor — Engine relay PWB
    5 Checking the LSU cleaning motor The LSU cleaning motor is not properly attached, or it is faulty. Reattach the LSU cleaning motor. If it is not repaired, replace it.
    6 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    7 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C4700
  • Description: VIDEO ASIC device error
  • Causes: 1. The communication with VIDEO ASIC failed 5 times continuously. 2. After writing the data to VIDEO ASIC, the value mismatching error repeated 8 times continuously by trying to read the data from the same address.
  • Remedy: 1 Resetting the main power The ASIC operation on the PWB is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version.
    3 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: C5101
  • Description: Charger error (Black)
  • Causes: Target: 40ppm model The rush-in current to drum unit K is less at the Vpp adjustment for the main charge adjustment
  • Remedy: 1 Checking the drum unit and the developer unit The drum or drum screw does not rotate normally Replace the drum unit if the drum or the drum screw does not rotate smoothly.
    2 Checking the main charger unit The main charger unit is not attached properly Reinstall the main charger unit on the drum unit properly. If it is not resolved, replace the main charger unit.
    3 Checking the connection FFC is not properly connected, or it is faulty. Clean the following FFC terminal of the FFC and reconnect. If the FFC terminal is deformed or FFC is short circuited, replace FFC. • High voltage PWB — Main/ engine PWB
    4 Replacing the high voltage PWB The high voltage PWB is faulty. Replace the high voltage PWB.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C5102
  • Description: Charger error (Cyan)
  • Causes: Target: 40ppm model The rush-in current to drum unit C is less at the Vpp adjustment for the main charge adjustment
  • Remedy: 1 Checking the drum unit and the developer unit The drum or drum screw does not rotate normally Replace the drum unit if the drum or the drum screw does not rotate smoothly.
    2 Checking the main charger unit The main charger unit is not attached properly Reinstall the main charger unit on the drum unit properly. If it is not resolved, replace the main charger unit.
    3 Checking the connection FFC is not properly connected, or it is faulty. Clean the following FFC terminal of the FFC and reconnect. If the FFC terminal is deformed or FFC is short circuited, replace FFC. • High voltage PWB — Main/ engine PWB
    4 Replacing the high voltage PWB The high voltage PWB is faulty. Replace the high voltage PWB.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C5103
  • Description: Charger error (Magenta)
  • Causes: Target: 40ppm model The rush-in current to drum unit M is less at the Vpp adjustment for the main charge adjustment
  • Remedy: 1 Checking the drum unit and the developer unit The drum or drum screw does not rotate normally Replace the drum unit if the drum or the drum screw does not rotate smoothly.
    2 Checking the main charger unit The main charger unit is not attached properly Reinstall the main charger unit on the drum unit properly. If it is not resolved, replace the main charger unit.
    3 Checking the connection FFC is not properly connected, or it is faulty. Clean the following FFC terminal of the FFC and reconnect. If the FFC terminal is deformed or FFC is short circuited, replace FFC. • High voltage PWB — Main/ engine PWB
    4 Replacing the high voltage PWB The high voltage PWB is faulty. Replace the high voltage PWB.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C5104
  • Description: Charger error (Yellow)
  • Causes: Target: 40ppm model The rush-in current to drum unit Y is less at the Vpp adjustment for the main charge adjustment
  • Remedy: 1 Checking the drum unit and the developer unit The drum or drum screw does not rotate normally Replace the drum unit if the drum or the drum screw does not rotate smoothly.
    2 Checking the main charger unit The main charger unit is not attached properly Reinstall the main charger unit on the drum unit properly. If it is not resolved, replace the main charger unit.
    3 Checking the connection FFC is not properly connected, or it is faulty. Clean the following FFC terminal of the FFC and reconnect. If the FFC terminal is deformed or FFC is short circuited, replace FFC. • High voltage PWB — Main/ engine PWB
    4 Replacing the high voltage PWB The high voltage PWB is faulty. Replace the high voltage PWB.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C6000
  • Description: Broken fuser heater 1 error
  • Causes: 1. During warm-up, the temperature detected by fuser thermistor 2 does not reach 100°C / 212°F when passing 20s. 2. During warm-up, when passing 30s after the temperature detected by fuser thermistor 2 reaches 100°C / 212°F , the ready state temperature is not reached.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    6 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    7 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6020
  • Description: Fuser thermistor 2 high temperature error
  • Causes: Fuser thermistor 2 detects 240°C / 464°F or more for 1s.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    3 Replacing the fuser unit The fuser thermistor cannot detect correct temperature due to foreign objects adhering to the fuser heat roller or fuser press roller, short-circuit of the fuser thermistor, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    6 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    7 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6030
  • Description: Broken fuser thermistor 1 error
  • Causes: Fuser thermistor 2 detects the low temperature for 1.6s when the fuser thermistor 1 detects 30 °C / 86 °F or more.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    6 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6040
  • Description: Fuser heater error
  • Causes: The input from fuser thermistor 2 is abnormal for 1s continuously.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    6 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6050
  • Description: Fuser thermistor 2 low temperature error
  • Causes: During standby or printing, the fuser thermistor 2 detected 100°C / 212°F or less for 1s continuously.
  • Remedy: 1 Checking the power supply voltage The power supply voltage reduces. Connect the power cord to a different wall outlet if the power supply voltage descends by 10% or more of the rated voltage, or multiple devices use the same outlet.
    2 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    4 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    7 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    8 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6200
  • Description: Fuser heater 1 error
  • Causes: Target: 30ppm model 1. During warm-up, the fuser thermistor 1 does not detect 100°C / 212°F if turning the fuser heater 1 on for 30s continuously. 2. During warm-up, if turning the fuser heater 1 on for 30s continuously after the temperature detected by the fuser thermistor 1 reaches 100°C / 212°F , the fuser thermistor 1 does not detect the ready state temperature.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    7 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    8 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6200
  • Description: Fuser heater 2 error
  • Causes: Target: 35/40ppm model 1. During warm-up, fuser thermistor 1 does not detect 100°C / 212°F if turning the fuser heater 2 on for 30s continuously. 2. During warm-up, if turning the fuser heater 2 on for 30s continuously after the temperature detected by the fuser thermistor 1 reaches 100°C / 212°F , fuser thermistor 1 does not detect the ready state temperature.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    7 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    8 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6220
  • Description: Fuser heater high temperature error
  • Causes: Fuser thermistor 1 detected 240 °C / 464 °F for 1s continuously
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    6 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
  • Code: C6230
  • Description: Broken fuser thermistor 1 error
  • Causes: Fuser thermistor 1 detected low temperature for 1.6s continuously
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB
    3 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    6 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6250
  • Description: Fuser thermistor 1 low temperature error
  • Causes: Fuser thermistor 1 detects a temperature lower than 100 °C / 212 °F for 1s in succession during ready or print
  • Remedy: 1 Checking the power supply voltage The power supply voltage reduces. Connect the power cord to a different wall outlet if the power supply voltage descends by 10% or more of the rated voltage, or multiple devices use the same outlet.
    2 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser unit (fuser thermistor) — Exit PWB • Exit PWB — Main/engine PWB • Low voltage PWB — Main/ engine PWB
    4 Replacing the fuser unit The normal temperature cannot be detected with the fuser heater not being turned on, broken fuser thermostat wire, etc. Replace the fuser unit.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
    7 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    8 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
  • Code: C6400
  • Description: Zero-cross signal error
  • Causes: The zero-cross signal is not input for 1s continuously when the fuser heater turns on and the 24V broken wire is not detected.
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Low voltage PWB — Main/ engine PWB
    2 Replacing the low voltage PWB The low voltage PWB is faulty. Replace the low voltage PWB when the fuser heaters always turn on.
    3 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C6610
  • Description: Press-release sensor error
  • Causes: The press-release sensor does not turn on or off after passing 30s from the start of the fuser compression or decompression.
  • Remedy: 1 Removing a piece of paper The fuser thermistor cannot detect the normal temperature with paper strip Remove a piece of paper remaining in the fuser unit.
    2 Checking the fuser pressure release operation The fuser press-release does not operate properly. Check if the pressure can be reduced by reverse-rotating the fuser gear
    3 Checking the pressrelease sensor The press-release sensor is not properly attached. Check if the press-release sensor is interrupted by the actuator during the decompression operation.
    4 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Press-release sensor — Exit PWB • Exit PWB — Main/engine PWB • Fuser motor — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    5 Checking the fuser motor The fuser motor is not properly attached, or it is faulty. Reattach the fuser motor. If it is not repaired, replace it.
    6 Replacing the fuser unit The parts such as the press-release sensor in the fuser unit are faulty. Replace the fuser unit.
    7 Replacing the exit PWB The exit PWB is faulty. Replace the exit PWB.
    8 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    9 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    10 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C6910
  • Description: Engine firmware unexpected error
  • Causes: 1. The drum motor drive continued for 60 min. or more while not printing. 2. The developer bias turns on while the main charger bias is off. (On for 3,263ms or more continuously) 3. The high voltage remote or main charger DC bias turns on while the drum motor is stopped. (On for 270ms or more continuously) 4. The periodic writing process to the EEPROM locked for 30s. (The EEPROM writing is not processed for 30s or other priority process occupies (locks) to have no process for the EEPROM.)
  • Remedy: 1 Reset the main power The main power start-up is slow. Turn the power switch off and unplug the power plug. After 5s, reconnect the power plug and turn the power switch on.
    2 Upgrade the firmware The firmware is not the latest version. Upgrade the engine firmware to the latest version.
    3 Check Main/Engine PWB Main/Engine PWB is not attached and connected properly. Fix Main/Engine PWB with screws and reconnect the connectors so that the ground is secured.
    4 Replace Main/Engine PWB Main/Engine PWB is faulty. Replace Main/Engine PWB.
  • Code: C7001
  • Description: Toner motor K error
  • Causes: The excess current signal was detected for 5s continuously
  • Remedy: 1 Replacing toner container K The spiral locks up. (It does not rotate.) Replace toner container K.
    2 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gears and the couplings in the toner motor unit and apply the grease to them.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Toner motor K — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking toner motor K Toner motor K is not properly attached, or it is faulty. Reattach toner motor K. If it is not repaired, replace it.
    5 Replacing the toner motor unit The toner motor unit is faulty. Replace the toner motor unit.
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    8 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7002
  • Description: Toner motor C error
  • Causes: The excess current signal was detected for 5s continuously
  • Remedy: 1 Replacing toner container C The spiral locks up. (It does not rotate.) Replace toner container C.
    2 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gears and the couplings in the toner motor unit and apply the grease to them.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Toner motor C — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking toner motor K Toner motor C is not properly attached, or it is faulty. Reattach toner motor C. If it is not repaired, replace it.
    5 Replacing the toner motor unit The toner motor unit is faulty. Replace the toner motor unit.
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    8 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7003
  • Description: Toner motor M error
  • Causes: The excess current signal was detected for 5s continuously
  • Remedy: 1 Replacing toner container M The spiral locks up. (It does not rotate.) Replace toner container M.
    2 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gears and the couplings in the toner motor unit and apply the grease to them.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Toner motor M — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking toner motor K Toner motor M is not properly attached, or it is faulty. Reattach toner motor M. If it is not repaired, replace it.
    5 Replacing the toner motor unit The toner motor unit is faulty. Replace the toner motor unit.
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    8 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7004
  • Description: Toner motor Y error
  • Causes: The excess current signal was detected for 5s continuously
  • Remedy: 1 Replacing toner container Y The spiral locks up. (It does not rotate.) Replace toner container Y.
    2 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gears and the couplings in the toner motor unit and apply the grease to them.
    3 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Toner motor Y — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    4 Checking toner motor K Toner motor Y is not properly attached, or it is faulty. Reattach toner motor Y. If it is not repaired, replace it.
    5 Replacing the toner motor unit The toner motor unit is faulty. Replace the toner motor unit.
    6 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    7 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    8 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7101
  • Description: Toner sensor K error
  • Causes: The sensor output value is 0.1v and less or 3.2v or more during a certain time.
  • Remedy: 1 Reinstalling toner container K The toner container is not properly installed. Reinstall toner container K.
    2 Replacing toner container K The toner supply opening of the toner container cannot be opened by operating the lever. Replace toner container K.
    3 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gear and the coupling and apply the grease to them.
    4 Correcting the toner supply opening The toner supply opening on the primary transfer unit is not opened even when installing toner container K. Correct the toner supply opening at the upper part of the primary transfer unit so that it is opened by the lever operation.
    5 Checking the primary transfer unit Toner is clogged at the toner supply path in the primary transfer unit Clean the inside of the primary transfer unit. If not resolved, replace it.
    6 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Developer unit K — Drum relay PWB • Drum relay PWB — Main/ engine PWB • Toner motor K — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    7 Replacing developer unit K The gear or spiral does not rotate in the developer unit, or toner sensor K is faulty. Replace developer unit K.
    8 Checking toner motor K Toner motor K is not properly attached, or it is faulty. Reattach toner motor K. If it is not repaired, replace it.
    9 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    10 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    11 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    12 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7102
  • Description: Toner sensor C error
  • Causes: The sensor output value is 0.1v and less or 3.2v or more during a certain time.
  • Remedy: 1 Reinstalling toner container C The toner container is not properly installed. Reinstall toner container C.
    2 Replacing toner container C The toner supply opening of the toner container cannot be opened by operating the lever. Replace toner container C.
    3 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gear and the coupling and apply the grease to them.
    4 Correcting the toner supply opening The toner supply opening on the primary transfer unit is not opened even when installing toner container C. Correct the toner supply opening at the upper part of the primary transfer unit so that it is opened by the lever operation.
    5 Checking the primary transfer unit Toner is clogged at the toner supply path in the primary transfer unit Clean the inside of the primary transfer unit. If not resolved, replace it.
    6 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Developer unit C — Drum relay PWB • Drum relay PWB — Main/ engine PWB • Toner motor C — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    7 Replacing developer unit C The gear or spiral does not rotate in the developer unit, or toner sensor C is faulty. Replace the developer unit C.
    8 Checking toner motor C Toner motor C is not properly attached, or it is faulty. Reattach toner motor C. If it is not repaired, replace it.
    9 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    10 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    11 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    12 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7103
  • Description: Toner sensor M error
  • Causes: The sensor output value is 0.1v and less or 3.2v or more during a certain time.
  • Remedy: 1 Reinstalling toner container M The toner container is not properly installed. Reinstall toner container M.
    2 Replacing toner container M The toner supply opening of the toner container cannot be opened by operating the lever. Replace toner container M.
    3 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gear and the coupling and apply the grease to them.
    4 Correcting the toner supply opening The toner supply opening on the primary transfer unit is not opened even when installing toner container M. Correct the toner supply opening at the upper part of the primary transfer unit so that it is opened by the lever operation.
    5 Checking the primary transfer unit Toner is clogged at the toner supply path in the primary transfer unit Clean the inside of the primary transfer unit. If not resolved, replace it.
    6 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Developer unit M — Drum relay PWB • Drum relay PWB — Main/ engine PWB • Toner motor M — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    7 Replacing developer unit M The gear or spiral does not rotate in the developer unit, or toner sensor M is faulty. Replace the developer unit M.
    8 Checking toner motor M Toner motor M is not properly attached, or it is faulty. Reattach toner motor M. If it is not repaired, replace it.
    9 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    10 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    11 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    12 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7104
  • Description: Toner sensor Y error
  • Causes: The sensor output value is 0.1v and less or 3.2v or more during a certain time.
  • Remedy: 1 Reinstalling toner container Y The toner container is not properly installed. Reinstall toner container Y.
    2 Replacing toner container Y The toner supply opening of the toner container cannot be opened by operating the lever. Replace toner container Y.
    3 Checking the driving parts The drive gear or the coupling do not properly rotate or the excessive load is applied to them. Clean the drive gear and the coupling and apply the grease to them.
    4 Correcting the toner supply opening The toner supply opening on the primary transfer unit is not opened even when installing toner container Y. Correct the toner supply opening at the upper part of the primary transfer unit so that it is opened by the lever operation.
    5 Checking the primary transfer unit Toner is clogged at the toner supply path in the primary transfer unit Clean the inside of the primary transfer unit. If not resolved, replace it.
    6 Checking the connection The connector or FFC is not connected properly. Or, the wire or FFC is faulty. Reconnect the following wire connectors and clean the FFC and reconnect. If there is no continuity, replace the wire. If the FFC terminal section is deformed or FFC is broken, replace the FFC. • Developer unit Y — Drum relay PWB • Drum relay PWB — Main/ engine PWB • Toner motor Y — Engine relay PWB • Engine relay PWB — Main/ engine PWB
    7 Replacing developer unit Y The gear or spiral does not rotate in the developer unit, or toner sensor Y is faulty. Replace the developer unit Y.
    8 Checking toner motor Y Toner motor Y is not properly attached, or it is faulty. Reattach toner motor Y. If it is not repaired, replace it.
    9 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    10 Replacing the engine relay PWB The engine relay PWB is faulty. Replace the engine relay PWB.
    11 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    12 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7200
  • Description: Developer thermistor error
  • Causes: The sensor input sampling exceeds the reference value. (After detection, controlled at 25 °C / 77.0 °F)
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert developer unit K into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Developer unit K — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    2 Replacing developer unit K Toner sensor K is faulty. Replace developer unit K.
    3 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7221
  • Description: LSU thermistor K error
  • Causes: The sensor input sampling exceeds the reference value. (After detection, controlled at 25 °C / 77.0 °F)
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(KM) (LSU thermistor K) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (KM).
    3 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7222
  • Description: LSU thermistor C error
  • Causes: The sensor input sampling exceeds the reference value. (After detection, controlled at 25 °C / 77.0 °F)
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU(CY) (LSU thermistor C) — Main/engine PWB
    2 LSU replacement The LSU is faulty. Replace the LSU (CY).
    3 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7401
  • Description: Developer unit K type mismatch error
  • Causes: The main unit and developer unit K is not matched.
  • Remedy: 1 Checking developer unit K The different type of the developer unit is installed. Install the correct developer unit.
  • Code: C7402
  • Description: Developer unit C type mismatch error
  • Causes: The main unit and developer unit C is not matched.
  • Remedy: 1 Checking developer unit C The different type of the developer unit is installed. Install the correct developer unit.
  • Code: C7403
  • Description: Developer unit M type mismatch error
  • Causes: The main unit and developer unit M is not matched.
  • Remedy: 1 Checking developer unit M The different type of the developer unit is installed. Install the correct developer unit.
  • Code: C7404
  • Description: Developer unit Y type mismatch error
  • Causes: The main unit and developer unit Y is not matched.
  • Remedy: 1 Checking developer unit Y The different type of the developer unit is installed. Install the correct developer unit.
  • Code: C7411
  • Description: Drum unit K type mismatch error
  • Causes: The main unit and drum unit K is not matched.
  • Remedy: 1 Checking drum unit K The different drum unit is installed. Install the proper drum unit.
  • Code: C7412
  • Description: Drum unit C type mismatch error
  • Causes: The main unit and drum unit C is not matched.
  • Remedy: 1 Checking drum unit C The different drum unit is installed. Install the proper drum unit.
  • Code: C7413
  • Description: Drum unit M type mismatch error
  • Causes: The main unit and drum unit M is not matched.
  • Remedy: 1 Checking drum unit M The different drum unit is installed. Install the proper drum unit.
  • Code: C7414
  • Description: Drum unit Y type mismatch error
  • Causes: The main unit and drum unit Y is not matched.
  • Remedy: 1 Checking drum unit Y The different drum unit is installed. Install the proper drum unit.
  • Code: C7601
  • Description: ID sensor 1 error (Machine left side)
  • Causes: The measurement value of the ID sensor apply either of the following. 1. The P-wave of the light potential is lower than the p-wave of the dark potential +0.5V. 2. The S-wave of the light potential is lower than the S-wave of the dark potential. 3. The P/S-wave is more than 0.8V, or lower than 0.15V.
  • Remedy: 1 Cleaning the ID sensors ID sensor 1 is dirty. Clean ID sensor 1 surface.
    2 Reattaching the ID sensor ID sensor 1 is not properly attached. Reattach ID sensor 1.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 1 — Main/engine PWB
    4 Replacing the ID sensor ID sensor 1 is faulty, so the error is detected when executing Calibration. Replace ID sensor 1.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7602
  • Description: ID sensor 2 error (Machine right side)
  • Causes: The measurement value of the ID sensor apply either of the following. 1. The P-wave of the light potential is lower than the p-wave of the dark potential +0.5V. 2. The S-wave of the light potential is lower than the S-wave of the dark potential. 3. The P/S-wave is more than 0.8V, or lower than 0.15V.
  • Remedy: 1 Cleaning the ID sensors ID sensor 2 is dirty. Clean ID sensor 2 surface.
    2 Reattaching the ID sensor ID sensor 2 is not properly attached. Reattach ID sensor 2.
    3 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 2 — Main/engine PWB
    4 Replacing the ID sensor ID sensor 2 is faulty, so the error is detected when executing Calibration. Replace ID sensor 2.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7611
  • Description: Bias calibration read value error (Black)
  • Causes: The ID sensor cannot read the patch image density on the transfer belt normally when executing Calibration.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Cleaning the ID sensors The ID sensor is dirty. Clean the surface of ID sensor 1, 2.
    3 Reexecuting Calibration Calibration failed last time. Execute [Calibration] in [System Menu/Counter] key > [Adjustment/Maintenance].
    Checking the ID sensor shutter The ID sensor shutter is not opened. Check if the ID sensor shutter opens and closes according to the paper tray opening and closing. If it does not open properly, repair it.
    5 Checking the primary transfer unit The transfer belt surface is dirty or scratched Clean the transfer belt surface. Or, replace the primary transfer unit.
    6 (When the image is too light) Checking the drum unit and developer unit The drum unit or developer unit parts are dirty or worn down. Clean drum unit K and developer unit K. If the parts are worn down, replace the unit.
    7 Reattaching the ID sensor The ID sensor is not attached properly Reattach ID sensor 1, 2.
    8 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 1, 2 — Main/engine PWB
    9 Replacing the ID sensor ID sensor 1, 2 are abnormal and an error is detected when executing Calibration. Replace ID sensor 1, 2.
    10 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    11 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7612
  • Description: Bias calibration read value error (Cyan)
  • Causes: The ID sensor cannot read the patch image density on the transfer belt normally when executing Calibration.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Cleaning the ID sensors The ID sensor is dirty. Clean the surface of ID sensor 1, 2.
    3 Reexecuting Calibration Calibration failed last time. Execute [Calibration] in [System Menu/Counter] key > [Adjustment/Maintenance].
    4 Checking the ID sensor shutter The ID sensor shutter is not opened. Check if the ID sensor shutter opens and closes according to the paper tray opening and closing. If it does not open properly, repair it.
    5 Checking the primary transfer unit The transfer belt surface is dirty or scratched Clean the transfer belt surface. Or, replace the primary transfer unit.
    6 (When the image is too light) Checking the drum unit and developer unit The drum unit or developer unit parts are dirty or worn down. Clean drum unit C and developer unit C. If the parts are worn down, replace the unit.
    7 Reattaching the ID sensor The ID sensor is not attached properly Reattach ID sensor 1, 2.
    8 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 1, 2 — Main/engine PWB
    9 Replacing the ID sensor ID sensor 1, 2 are abnormal and an error is detected when executing Calibration. Replace ID sensor 1, 2.
    10 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    11 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7613
  • Description: Bias calibration read value error (Magenta)
  • Causes: The ID sensor cannot read the patch image density on the transfer belt normally when executing Calibration.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Cleaning the ID sensors The ID sensor is dirty. Clean the surface of ID sensor 1, 2.
    3 Reexecuting Calibration Calibration failed last time. Execute [Calibration] in [System Menu/Counter] key > [Adjustment/Maintenance].
    4 Checking the ID sensor shutter The ID sensor shutter is not opened. Check if the ID sensor shutter opens and closes according to the paper tray opening and closing. If it does not open properly, repair it.
    5 Checking the primary transfer unit The transfer belt surface is dirty or scratched Clean the transfer belt surface. Or, replace the primary transfer unit.
    6 (When the image is too light) Checking the drum unit and developer unit The drum unit or developer unit parts are dirty or worn down. Clean drum unit M and developer unit M. If the parts are worn down, replace the unit.
    7 Reattaching the ID sensor The ID sensor is not attached properly Reattach ID sensor 1, 2.
    8 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 1, 2 — Main/engine PWB
    9 Replacing the ID sensor ID sensor 1, 2 are abnormal and an error is detected when executing Calibration. Replace ID sensor 1, 2.
    10 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    11 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7614
  • Description: Bias calibration read value error (Yellow)
  • Causes: The ID sensor cannot read the patch image density on the transfer belt normally when executing Calibration.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Cleaning the ID sensors The ID sensor is dirty. Clean the surface of ID sensor 1, 2.
    3 Reexecuting Calibration Calibration failed last time. Execute [Calibration] in [System Menu/Counter] key > [Adjustment/Maintenance].
    4 Checking the ID sensor shutter The ID sensor shutter is not opened. Check if the ID sensor shutter opens and closes according to the paper tray opening and closing. If it does not open properly, repair it.
    5 Checking the primary transfer unit The transfer belt surface is dirty or scratched Clean the transfer belt surface. Or, replace the primary transfer unit.
    6 (When the image is too light) Checking the drum unit and developer unit The drum unit or developer unit parts are dirty or worn down. Clean drum unit Y and developer unit Y. If the parts are worn down, replace the unit.
    7 Reattaching the ID sensor The ID sensor is not attached properly Reattach ID sensor 1, 2.
    8 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 1, 2 — Main/engine PWB
    9 Replacing the ID sensor ID sensor 1, 2 are abnormal and an error is detected when executing Calibration. Replace ID sensor 1, 2.
    10 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    11 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7620
  • Description: Automatic color registration failure
  • Causes: The image patch position on the transfer belt is outside the range of the ID sensor reading. The transfer belt surface is dirty or image patch density is light.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Cleaning the ID sensors The ID sensor is dirty. Clean the surface of ID sensor 1, 2.
    3 Reexecuting Calibration Calibration failed last time. Execute [Calibration] in [System Menu/Counter] key > [Adjustment/Maintenance].
    4 Checking the ID sensor shutter The ID sensor shutter is not opened. Check if the ID sensor shutter opens and closes according to the paper tray opening and closing. If it does not open properly, repair it.
    5 Checking the primary transfer unit The transfer belt surface is dirty or scratched Clean the transfer belt surface. Or, replace the primary transfer unit.
    6 (When the image is too light) Checking the drum unit, developer unit and LSU The parts for the drum unit, developer unit and LSU is dirty or worn out. Clean drum unit Y, developer unit Y and the LSU. If the parts are worn down, replace the unit.
    7 (When the color shift occurs) Checking the LSU and the drum unit The LSU or drum unit is not installed in the proper position. The LSU is faulty. Reinstall the LSU and the drum unit. If it is not resolved, replace the LSU.
    8 Reattaching the ID sensor The ID sensor is not attached properly Reattach ID sensor 1, 2.
    8 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • ID sensor 1, 2 — Main/engine PWB
    Replacing the ID sensor ID sensor 1, 2 are abnormal and an error is detected when executing Calibration. Replace ID sensor 1, 2.
    10 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    11 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7800
  • Description: Outer thermistor error
  • Causes: The sensor input sampling exceeds the reference value. (After detection, controlled at 25 °C / 77.0 °F)
  • Remedy: 1 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Outer temperature sensor — Main engine PWB
    2 Checking the outer temperature sensor The outer temperature sensor is not properly attached, or it is faulty. Reattach the outer temperature sensor. If it is not repaired, replace it.
    3 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    4 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7901
  • Description: Drum unit EEPROM error (Black)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in drum unit K is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert drum unit K into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Drum unit K — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing drum unit K The EEPROM in drum unit K is faulty. Replace drum unit K.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7902
  • Description: Drum unit EEPROM error (Cyan)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in drum unit C is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert drum unit C into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Drum unit C — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing drum unit C The EEPROM in drum unit C is faulty. Replace drum unit C.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7903
  • Description: Drum unit EEPROM error (Magenta)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in drum unit M is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert drum unit M into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Drum unit M — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing drum unit M The EEPROM in drum unit M is faulty. Replace drum unit M.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7904
  • Description: Drum unit EEPROM error (Yellow)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in drum unit Y is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert drum unit Y into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Drum unit Y — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing drum unit Y The EEPROM in drum unit Y is faulty. Replace drum unit Y.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7911
  • Description: Developer unit EEPROM error (Black)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in developer unit K is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert developer unit K into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Developer unit K — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing developer unit K The EEPROM in developer unit K is faulty. Replace developer unit K.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7912
  • Description: Developer unit EEPROM error (Cyan)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in developer unit C is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert developer unit C into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Developer unit C — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing developer unit C The EEPROM in developer unit C is faulty. Replace the developer unit C.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7913
  • Description: Developer unit EEPROM error (Magenta)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in developer unit M is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert developer unit M into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Developer unit M — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing developer unit M The EEPROM in developer unit M is faulty. Replace the developer unit M.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C7914
  • Description: Developer unit EEPROM error (Yellow)
  • Causes: 1. No response from the device is detected for 5ms or more 5 times continuously when reading / writing the data. 2. The reading data of 2 points mismatches 8 times continuously. 3. The reading data and the writing data mismatch 8 times continuously.
  • Remedy: 1 Resetting the main power The EEPROM data in developer unit Y is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Reinsert developer unit Y into the main unit all the way to reconnect the connector. Also, if the wire is faulty, replace it. • Developer unit Y — Drum relay PWB • Drum relay PWB — Main/ engine PWB
    3 Replacing developer unit Y The EEPROM in developer unit Y is faulty. Replace the developer unit Y.
    4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    5 Replacing the drum relay PWB The drum relay PWB is faulty. Replace the drum relay PWB.
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C9180
  • Description: DP reverse motor error
  • Causes: Target: 30ppm model For the internal count The home position cannot be detected at 3 time of retries. .*HP (home position) detection: Retry is executed if HP is not detected after driving the DP reversing motor for one round when moving to HP.
  • Remedy: 1 Resetting the main power The DP reverse motor is not controlled normally. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP reverse motor — Main/ engine PWB • DP reverse sensor — Main/ engine PWB
    3 Checking the DP reverse motor The DP reverse motor does not normally rotate, or it is faulty. Remove the DP reverse motor and fix it by rotating the drive parts manually. Then, reattach it. If not fixed, replace it.
    4 Checking the DP reverse sensor The DP reverse sensor is not properly attached, or it is faulty. Reattach the DP reverse sensor. If it is not repaired, replace it.
    5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    6 Main/engine PWB replacement The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: C9540
  • Description: Backup data error
  • Causes: When multiple parts are replaced at the same time, the internal data is changed and it interferes with the machine operation. Consequently, the main unit cannot recover.
  • Remedy: 1 Checking the PWB Multiple PWBs were replaced at the same time. Recover to the original, if 2 or more of the following related parts were replaced at the same time. • Related parts: Memory, each PWB
    2 Checking the unit Multiple units were replaced at the same time. Be sure not to perform the following works at the same time when the memory or each PWB is replaced. • Replacing the drum unit or the developer unit
  • Code: F000
  • Description: System Error
  • Causes: Communication error between the main/engine PWB and the operation panel PWB
  • Remedy: 1 Resetting the main power The communication is faulty between the main/ engine PWB and the operation panel PWB. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Main/engine PWB — Operation panel PWB
    3 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data.
    4 Replacing the main/engine PWB The main/engine PWB is faulty. Replace the main/engine PWB.
    5 Replacing the operation panel PWB The operation panel PWB is faulty. Replace the operation panel PWB.
  • Code: F010
  • Description: System Error
  • Causes: Program ready error
  • Remedy: 1 Resetting the main power The checksum in the main/ engine PWB is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: F020
  • Description: System Error
  • Causes: RAM checksum error
  • Remedy: 1 Resetting the main power The checksum in the main/ engine PWB is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: F040
  • Description: System Error
  • Causes: Communication error between the controller and the print engine
  • Remedy: 1 Resetting the main power The communication between the controller and the print engine is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    2 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: F050
  • Description: System Error
  • Causes: Print engine main program error
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version
    2 Resetting the main power The print engine ROM checksum is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch.
    3 Reinstalling the EEPROM The EEPROM is not properly attached. Reattach the EEPROM on the main/engine PWB.
    4 Checking the main/engine PWB The connector and FFC are not connected properly or the wire, FFC or PWB is faulty. Clean the terminal of the connectors on the main/engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main/engine PWB.
  • Code: F12X
  • Description: System Error
  • Causes: An error is detected at scan control section
  • Remedy: 1. Check the wire or connector between Scan/DP PWB (CCD PWB or DP relay PWB) and Main/ engine PWB and correct it if necessary. (Reconnect the connector or replace the wire) Check the operation after that. 2. Execute U021 (Init memory) and check function. 3. Replace the CCD PWB or DP relay PWB and check function. 4. Replace the main/engine PWB and check function. 5. Retrieve the USBLOG and contact the Service Administrative Division.
    Authentication device: Card Reader, etc.
  • Code: F14D
  • Description: System Error
  • Causes: An error in the FAX control section is detected.
  • Remedy: 1 Reinstalling the firmware The firmware is faulty. Reinstall the firmware.
    2 Checking the connection The connector is not properly connected or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • FAX PWB — Main/engine PWB
    3 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB.
    4 Replacing the main/engine PWB The main/engine PWB is faulty. Replace the main/engine PWB.
  • Code: F14X
  • Description: System Error
  • Causes: An error is detected at the FAX control section
  • Remedy: 1. Check the wire or connector between FAX PWB, IO replay PWB and Main/engine PWB and correct it if necessary. (Reconnect the connector or replace the wire) Check the operation after that. 2. Execute U021 (Init memory) and check function. 3. Replace the FAX PWB and check function. 4. Replace the main/engine PWB and check function. 5. Retrieve the USBLOG and contact the Service Administrative Division.
    [Checking the FAX connector connection] FAX exclusive I/F (It is not the eKUIO)
  • Code: F15X
  • Description: System Error
  • Causes: An error is detected at the authentication device control section
  • Remedy: 1. Check the wire or connector between the authentication device and Main/engine PWB and correct it if necessary. (Reconnect the connector or replace the wire) Check the operation after that. 2. Execute U021 (Init memory) and check function. 3. Replace the main/engine PWB and check function. 4. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F17X
  • Description: System Error
  • Causes: An error is detected at the print data control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F18X
  • Description: System Error
  • Causes: An error is detected at the Video control secion
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F1DX
  • Description: System Error
  • Causes: An error is detected at the Image memory management section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
    * Poor arrangement of F1D4:Random Access Memory (1) Confirmation of U340 (2) Initialization of a set point (U021)
  • Code: F21X, F22X, F23X
  • Description: System Error
  • Causes: An error is detected at the Image processing section
  • Remedy: 1. Check contact of the DIMM by releasing and reinserting, and check the function. Replace DIMM if available, and check function. 2. Execute U021 (Init memory) and check function. 3. Replace the main/engine PWB and check function. 4. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F24X
  • Description: System Error
  • Causes: An error is detected at the System management section
  • Remedy: 1. Check contact of the DIMM by releasing and reinserting, and check the function. Replace DIMM if available, and check function.??? 2. Execute U021 (Init memory) and check function. 3. Replace the main/engine PWB and check function. 4. Retrieve the USBLOG and contact the Service Administrative Division.
    F248 eror is printer process error. If it repeats with a certain print data, retrieve the capture data and USBLOG.
  • Code: F25X
  • Description: System Error
  • Causes: Abnormality detecting in a network management department
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
    [Main body to External network] Ethernet connector
  • Code: F26X … F2AX
  • Description: System Error
  • Causes: An error is detected at the System management section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F2BX … F32X
  • Description: System Error
  • Causes: Abnormality detecting in a network control part
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F33X
  • Description: System Error
  • Causes: An error is detected at the Scan management section
  • Remedy: 1. Check the wire or connector between Scan/DP PWB (CCD PWB or DP relay PWB) and Main/ engine PWB and correct it if necessary. (Reconnect the connector or replace the wire) Check the operation after that. 2. Execute U021 (Init memory) and check function. 3. Replace the operation panel PWB and check function. 4. Replace the main/engine PWB and check function. 5. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F34X
  • Description: System Error
  • Causes: An error is detected at the Panel management section
  • Remedy: 1. Check the wire and the connection of the connectors between the operation panel PWB and the main/engine PWB, and check function. (For HyPAS model only) 2. Execute U021 (Init memory) and check function. 3. Replace the operation panel PWB and check function. (For HyPAS model only) 4. Replace the main/engine PWB and check function. 5. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F35X
  • Description: System Error
  • Causes: An error is detected at the Print control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F38X
  • Description: System Error
  • Causes: An error is detected at the Authentication/ permit management section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F3AX … F45X
  • Description: System Error
  • Causes: An error is detected at the Entity control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F46X
  • Description: System Error
  • Causes: An error is detected at the Print image process section
  • Remedy: 1. Replace the main/engine PWB and check function. 2. Retrieve the USBLOG and contact the Service Administrative Division. (or retrieve the print capture data by case)
    F46F eror is printer process error. If it repeats with a certain print data, retrieve the capture data and USBLOG.
  • Code: F47X, F48X
  • Description: System Error
  • Causes: An error is detected at the Image edit process control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F4DX
  • Description: System Error
  • Causes: An error is detected at the Entity control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F4FX
  • Description: System Error
  • Causes: An error is detected at the Job control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F50X
  • Description: System Error
  • Causes: An error is detected at the FAX control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F52X … F57X
  • Description: System Error
  • Causes: An error is detected at the Job control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F63X
  • Description: System Error
  • Causes: An error is detected at the Device control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F68X
  • Description: System Error
  • Causes: An error is detected at the Storage device control section
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F90X
  • Description: System Error
  • Causes: Abnormality detecting in the extension application service part
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F93X
  • Description: System Error
  • Causes: Abnormality detecting in the extension application management part
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F9FX
  • Description: System Error
  • Causes: Abnormality detecting in the extension application various service part
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: FC0X
  • Description: System Error
  • Causes: Abnormality detecting in system application
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: FCAX
  • Description: System Error
  • Causes: Abnormality detecting in Print application
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: FD4X
  • Description: System Error
  • Causes: Abnormality detecting in Box application
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: FD9X
  • Description: System Error
  • Causes: Abnormality detecting in FAX application
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division
  • Code: FDEX
  • Description: System Error
  • Causes: Abnormality detecting in maintenance application
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: FF7X
  • Description: System Error
  • Causes: Abnormality detecting in a report creation part
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
    [Controller failure] Only turn off/on the power to solve the problem. It is necessary to provide USBLOG for the investigation.
  • Catalog

  • Sign In

  • Contacts

  • Forum

  • Eng

  • Error Codes
  • Kyocera
  • FSC8020MFP
  • Code 7004
  • Code: 7004
  • Description: Toner motor Y error
    When the toner motor Y is driven, error signal is detected continuously for 1 s.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner motor Y and engine PWB(YC8)
    Defective drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective motor. Replace the toner motor Y.
    Defective PWB. Replace the engine PWB check for correct operation.

Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.

В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.

Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.

Код ошибки Описание ошибки Причина ошибки 0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. 0070 FAX control PWB incompatible detection Error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. FAX control PWB (The FAX PWB installed will not be the one designed for the machine. 0100 Backup memory device error EEPROM (Control PWB) 0120 MAC address data error
For data in which the MAC address is invalid. EEPROM (Control PWB) 0130 Backup memory read/write error (main NAMD) Flash memory (Control PWB) 0140 Backup memory data error (main NAND) Flash memory (Control PWB) 0150 Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM. 0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Defective PWB. 0180 Machine number mismatch
Machine number of control does not match. Data damage of EEPROM. 0600 Expanded memory (DIMM) installing error
The expansion memory modules (DIMM) are not correctly mounted. Improper installation expanded memory (DIMM). 0610 Expanded memory (DIMM) error
The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly. Defective expanded memory (DIMM). Defective main PWB. 0640 Hard disk error
The hard disk cannot be accessed. Defective hard disk. Defective main PWB. 0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB. Defective FAX software. Defective FAX control PWB. 0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Defective main PWB. 0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Defective FAX control PWB or main PWB. 0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. 0930 EEPROM bus error Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB. 1010 Lift motor error
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB. 1020 PF lift motor error (paper feeder 1)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1030 PF lift motor error (paper feeder 2)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1500 PF heater 1 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1510 PF heater 2 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1520 PF heater 1 high temperature error (paper feeder 2)
A temperature higher than 75aC/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1530 PF heater 2 high temperature error (paper feeder 2)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1600 PF heater 1 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1610 PF heater 2 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1620 PF heater 1 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1630 PF heater 2 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1800 Paper feeder communication error
Communication error between engine PWB and optional paper feeder. Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB. 2100 Developing motor error
The developing motor ready input is not given for 5 s during the main motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB. 2200 Drum motor error
The drum motor ready input is not given for 5 s during the drum motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB. 2330 Fuser pressure release motor error
When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2340 Fuser pressure release motor time-out error
When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2500 Paper feed motor error
The drum motor ready input is not given for 5 s during the paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB. 2600 PF paper feed motor error (paper feeder 1)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB 2610 PF paper feed motor error (paper feeder 2)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB. 2730 Developing release motor error
When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2740 Developing release motor time-out error
When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2820 Fuser motor error
The fuser motor ready input is not given for 5 s during the fuser motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB. 3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB. 3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3300 AGC error
After AGC, correct input is not obtained at CCD. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3500 Communication error between scanner and ASIC
An error code is detected. Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB. 4001 Polygon motor KM error
The polygon motor KM ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor KM. Defective engine PWB. 4002 Polygon motor CY error
The polygon motor CY ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor CY. Defective engine PWB. 4201 Laser output error (black)
The pin photo signal is not output from PD PWB K for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB. 4202 Laser output error (cyan)
The pin photo signal is not output from PD PWB C for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4203 Laser output error (magenta)
The pin photo signal is not output from PD PWB M for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4204 Laser output error (yellow)
The pin photo signal is not output from PD PWB Y for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4600 LSU cleaning motor error
When the LSU cleaning motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB. 4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB. 5301 Broken cleaning lamp K wire
When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5302 Broken cleaning lamp C wire
When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5303 Broken cleaning lamp M wire
When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5304 Broken cleaning lamp Y wire
When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 6000 Broken fuser heater wire
The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s in warming up. The fuser temperature does not reach 100„aC/212„aF after the fuser heater has been turned on continuously for 30 s in warming up. The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s during printing. Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6020 Abnormally high fuser thermistor temperature
The fuser thermistor detects a temperature higher than 240C/464F. By the activation of the high temperature error detection circuit (230C/446F or more) of fuser thermistor, the illumination of fuser heater was forcibly turned off and 10 s has elapsed. Shorted fuser thermistor. Defective engine PWB. 6030 Broken fuser thermistor wire
Input from fuser thermistor is 3 or less (A/D value) continuously for 1 s. Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6400 Zero-cross signal error
The zero-cross signal does not reach the engine PWB for more than 1 s. Defective connector cable or poor contact in the connector. Defective power source PWB or engine PWB 7001 Toner motor K error
When the toner motor K is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7002 Toner motor C error
When the toner motor C is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7003 Toner motor M error
When the toner motor M is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7004 Toner motor Y error
When the toner motor Y is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7401 Developing unit K noninstalling error
No density detection signal is output from toner sensor K in developing unit K. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7402 Developing unit C noninstalling error
No density detection signal is output from toner sensor C in developing unit C. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7403 Developing unit M noninstalling error
No density detection signal is output from toner sensor M in developing unit M. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7404 Developing unit Y noninstalling error
No density detection signal is output from toner sensor Y in developing unit Y. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7411 Drum unit K non- installing error
The EEPROM of drum PWB K does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7412 Drum unit C non- installing error
The EEPROM of drum PWB C does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7413 Drum unit M non- installing error
The EEPROM of drum PWB M does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7414 Drum unit Y non- installing error
The EEPROM of drum PWB Y does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 9500

9520 Contact the Service Administrative Division. 9530 Backup data error
The serial number of the machine written on the EEPROM of the engine PWB differs with that is written on both the flash memory of the engine PWB and the EEPROM of the drum PWB as a backup. Replacing both the engine PWB and the drum unit at the same time. F000 Main PWB — operation panel PWB communication error Defective main PWB. Defective operation panel PWB. F010 Main PWB checksum error Defective main PWB F020 Main PWB RAM checksum errors Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM). F040 Main PWB — print engine communication error Defective main PWB. Defective engine PWB. F041 Main PWB — scanner engine communication error Defective main PWB. Defective engine PWB. F050 Print engine ROM checksum error Defective engine PWB. F051 Scanner engine ROM checksum error Defective engine PWB. F278 Power supply in drive system error Main power switch was turned off without using the power key, or a power failure has occurred.

Code

Contents

7004

Toner motor Y error

When the toner motor Y is

driven, the motor over-current

detection signal is detected

continuously for 50 times (5 s)

at 100 ms intervals.

7401

Developing unit K non-

installing error

No density detection signal is

output from toner sensor K in

developing unit K.

7402

Developing unit C non-

installing error

No density detection signal is

output from toner sensor C in

developing unit C.

7403

Developing unit M non-

installing error

No density detection signal is

output from toner sensor M in

developing unit M.

Causes

Defective connec-

Reinsert the connector. Also check for conti-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

nector.

Toner motor Y and engine PWB (YC26)

Defective drive

Check if the rollers and gears rotate

transmission sys-

smoothly. If not, grease the bushes and

tem of the toner

gears. Check for broken gears and replace if

motor Y.

any.

Defective toner

Replace the toner motor Y.

motor Y.

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

Reinsert the connector. Also check for conti-

Defective connec-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

nector.

Developing unit K and Drum relay PWB

(YC6)

Drum relay PWB (YC1) and engine PWB

(YC34)

Defective toner

Replace the developing unit K (see page 1-

sensor K.

5-18).

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

Defective connec-

Reinsert the connector. Also check for conti-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

Developing unit C and Drum relay PWB

nector.

(YC10)

Drum relay PWB (YC1) and engine PWB

(YC34)

Defective toner

Replace the developing unit C (see page 1-

sensor C.

5-18).

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

Defective connec-

Reinsert the connector. Also check for conti-

tor cable or poor

nuity within the connector cable. If none,

contact in the con-

replace the cable.

nector.

Developing unit M and Drum relay PWB

(YC7)

Drum relay PWB (YC1) and engine PWB

(YC34)

Defective toner

Replace the developing unit M (see page 1-

sensor M.

5-18).

Defective engine

Replace the engine PWB and check for cor-

PWB.

rect operation (see page 1-5-26).

1-4-25

Check procedures/

corrective measures

2KT/2KV

Индикатор ошибки на Kyocera TASKalfa 1800/2200Если с аппаратом Kyocera TASKalfa 1800, Kyocera TASKalfa 2200 произошла проблема, откроется следующий экран с уведомлением.
• Индикатор [Внимание] на панели управления горит или мигает.
• На дисплее сообщений панели управления аппарата появилось сообщение об ошибке.

Если индикатор [Внимание] горит или мигает и на дисплее сообщений панели управления аппарата появилось сообщение об ошибке, проверьте KYOCERA Client Tool или Монитор состояния.

ПРИМЕЧАНИЕ Если индикаторы постоянно горят и мигают не так, как описано выше, вероятно, произошла ошибка службы. Выключите питание, отсоедините шнур питания и вставьте его обратно, после чего включите питание. Это может помочь сбросить ошибку. Если ошибка не исчезает, свяжитесь со своим представителем сервисной службы (тел. в Минске +375 17 291-28-24)

Ниже описаны неполадки, которые не могут быть устранены пользователем

Дисплей сообщений

Описание

Меры устранения

Бункер отраб тонера перепол. или не уст.

Бункер для отработанного тонера установлен неправильно

Установите Бункер для отработанного тонера должным образом

Бункер для отработанного тонера заполнен

Замените бункер отработанного тонера

Встряхните картр. с тонером

Тонер слежался

Откройте переднюю крышку аппарата и вытяните контейнер с тонером. Сильно встряхните контейнер с тонером и установите его на место

Вызовите сервисный персонал.

В аппарате произошла ошибка

Обратите внимание на код ошибки, отображаемый в дисплее сообщений, и свяжитесь с представителем сервисной службы (тел. в Минске +375 17 291-28-24)

Выньте бумагу с внутреннего лотка

 

Извлеките бумагу из внутреннего лотка. Нажмите клавишу [OK], чтобы возобновить печать

Добавьте тонер

Закончился тонер

Замените контейнер с тонером TK-4105

Загрузите бумагу в кассету #

↑↓ (отображается попеременно)
A4 (формат бумаги)
Обычная (тип носителя)
OK: Перейдите к следующему шагу

Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.]

Загрузите бумагу в универсальный лоток

↑↓ (отображается попеременно)
A4 (формат бумаги)
Обычная (тип носителя)
OK: Перейдите к следующему шагу

Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.]

Закройте автоподатчик оригиналов

Открыт автоподатчик оригиналов

Откройте и закройте автоподатчик оригиналов

Закройте крышку автопод. оригиналов

Открыта верхняя крышка автоподатчика оригиналов

Откройте и закройте крышку автоподатчика оригинало

Закройте переднюю крышку

Открыта передняя крышка

Откройте и закройте переднюю крышку

Закройте правую крышку #

Открыта какая-либо крышка

Откройте и закройте крышку, обозначенную на экране

Замятие бумаги. (DP)
↑↓ (отображается попеременно)
Проверьте (B)(C) в крышке DP

В автоподатчике произошло замятие бумаги.

См. Устранение замятия бумаги в Руководстве по эксплуатации и извлеките замятую бумагу

Замените МК

Необходимо производить замену деталей комплекта техобслуживания MK-4105 (ремкомплекта) каждые 150 000 страниц печати.

Данная операция должна производиться специалистом. Обратитесь к представителю сервисной службы (тел. в Минске +375 17 291-28-24)

Замятие

Произошло замятие бумаги в кассете или универсальном лотке

См. Устранение замятия бумаги и извлеките замятую бумагу

Извлеките оригиналы из автоподатчика

Для продолжения работы необходимо извлечь оригиналы из автоподатчика оригиналов

Извлеките оригиналы из автоподатчика оригиналов

Кабель USB был отключен

Кабель USB не подключен

Нажмите клавишу [OK] и подключите кабель USB

ПК выключен

Нажмите клавишу [OK] и включите ПК

Не удается найти KYOCERA Client Tool

Нажмите клавишу [OK] и откройте KYOCERA Client Tool на ПК

Макс. к-во сканируемых страниц

Превышен предел сканирования

Дальнейшее сканирование невозможно. Задание отменено. Нажмите клавишу [OK]

Мало тонера. (Зам., когда законч.)

Скоро понадобится заменить контейнер с тонером 

Получите новый контейнер с тонером TK-4105. 
Внимание! Когда заканчивается тонер аппарат перестает печатать

Не оригинальный тонер

Установлен контейнер с тонером не марки Kyocera

Производитель не несет ответственности за повреждения, вызванные использованием неоригинального тонера. Мы рекомендуем использовать исключительно оригинальные контейнеры с тонером  TK-4105. .
Если нужно использовать установленный в настоящее время контейнер с тонером, нажмите одновременно и удерживайте клавиши [OK] и [Стоп] в течение не менее 3 с.

Неверный ид. уч. зап. Задание отменено

Указан неверный идентификатор учетной записи при внешней обработке задания. Задание отменено

Нажмите клавишу [OK]

Невозможна двусторонняя печать на этой бумаге

Не возможна печать на бумаге выбранного формата или типа

Нажмите клавишу [OK] и перейдите к следующему шагу:
• Для выбора другого устройства подачи выберите пункт [Выберите бумагу].
• Чтобы печатать, не используя функцию двусторонней печати, выберите пункт [Продолж. без изм.].

Недостаточно памяти. Невозможно начать выполнение задания

Невозможно начать выполнение задания

Повторите попытку позже

Ограничено алгоритмом учета заданий(Печать)

Задание отменено, поскольку его выполнение ограничено функцией учета заданий

Нажмите клавишу [OK]

Ограничено алгоритмом учета заданий(Сканер)

Задание отменено, поскольку его выполнение ограничено функцией учета заданий

Нажмите клавишу [OK]

Очистите сканер

Произошло загрязнение сканера

Очистите щелевое стекло с помощью чистящей салфетки, поставляемой вместе с автоподатчиком оригиналов.

Ошибка. Выключить

Отключите и снова включите аппарат с помощью выключателя питания

Память переполнена

Невозможно продолжить выполнение задания из-за отсутствия свободной памяти

Измените разрешение печати с Быстр1200 до 600 dpi. См. Printer Driver User Guide

Память сканера переполнена

Дальнейшее сканирование невозможно из-за нехватки памяти сканера.

Для отмены задания нажмите [OK]

Перезагрузка печати. Задание отменено

Предупреждение. Недостаточно памяти принтера. Задание отменено

Нажмите клавишу [OK]

Превышено ограничение учета заданий

Превышено число распечаток из-за ограничения алгоритмом учета заданий. Достигнут предел печати

Это задание отменено. Нажмите клавишу [OK]

Уст.другую кассету

Выбрано «Сдвиг»

Для использования сдвига необходимо загрузить в другой лоток бумагу такого же формата, что и в выбранном устройстве подачи, но в другой ориентации

Установите все оригиналы обратно и нажмите клавишу [Старт].

Возникает при печати двусторонних документов в режиме ручной двусторонней печати

Извлеките оригиналы из автоподатчика оригиналов, расположите их в первоначальном порядке и положите обратно. Нажмите клавишу [OK], чтобы возобновить печать. Для отмены задания нажмите [Стоп]

Установлен неизвестный тонер. ПК

Региональная спецификация контейнера с тонером не соответствует спецификации аппарата

Установите оригинальный контейнер с тонером Замените контейнер с тонером TK-4105

Чем мы можем вам сегодня помочь?

Изменено: Чт, 12 Июл, 2018 at 3:35 PM


В машинах Kyocera P6021cdn, P6026cdn, M6026cdn/cidn, M6526cdn/cidn, FSC5150/5250/5350 и многих других довольно часто приходится сталкиваться с ошибкам C7401, C7402, C7403, C7404.

Описание этих ошибок в сервисной документации такое: «Developing unit non-installing error».  Суть ошибок — машина не «видит» сигнала с датчика концентрации тонера в блоке проявки (7401 –Black, 7402 – Cyan, 7403 – Magenta, 7404 – Yellow). 

Т.е. показания датчика выходят за допустимый диапазон, что может быть вызвано чрезмерно низкой концентрацией тонера в девелопере или недостаточным количеством девелопера в блоке проявки. Предлагаемый сервисной документацией способ устранения проблемы обычно заканчивается весьма дорогим пунктом — заменой блоков проявки целиком.

Частые причины появления проблемы – использование «не очень совместимого» тонера или использование машины не по своему назначению. Машины предназначены для офисной печати в нормальных условиях, и не очень хорошо справляются с печатью при высоком или низком заполнении тонером напечатанных страниц, а также в условиях высокой или низкой влажности воздуха.

Рекомендуемый нами метод лечения, опробованный на нескольких машинах:

  • Для очистки совести проверить разъемы и провода на пути от датчиков концентрации тонера до платы.
  • Проверить систему подачи тонера – часто ломаются шестерни шнеков подачи тонера, которые находятся в блоке ленты переноса.

  • Опустить магнит в бункер отработки, чтобы выяснить имел ли место «вынос» девелопера в отработку.
  • При отсутствии девелопера в бункере отработки вручную добавить и распределить тонер в блок проявки. Добавлять через входное отверстие блока проявки, распределять вращением валов блока проявки за шестерню. Обычно для вывода машины из состояния ошибки достаточно добавить 3-5 г тонера и вращать вручную шестерню блока проявки 2-3 минуты.

  • При присутствии девелопера в бункере отработки сначала вручную добавить совместимый носитель в блок проявки, затем тонер. Добавлять через входное отверстие блока проявки, распределять вращением валов блока проявки за шестерню. Примерное количество носителя, которое нужно добавить, можно выяснить сравнением веса проблемного и «живого» блока проявки.
  • После входа машины на готовность запустить из меню машины процедуру DEV-CLN (1 раз, чтобы не заклинить систему вывода отработки!) затем калибровку цвета. Это позволит машине довести концентрацию тонера до установленных значений.

Профилактика:

  • Обновление прошивки. Kyocera иногда вносит в прошивки коррекции, связанные с алгоритмом подкачки тонера. 
  • Использование «нормального» тонера.
  • Беседа с клиентом о том, что офисная машина предназначена для печати офисных документов, а не для оперативной полиграфии и т.п.

Была ли эта статья полезной?
Да

Нет

Отправить отзыв

К сожалению, мы не смогли помочь вам в разрешении проблемы. Ваш отзыв позволит нам улучшить эту статью.

Статьи по теме

    Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.

    В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
    Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.

    Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
    8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.

    Код ошибки

    Описание ошибки

    Причина ошибки

    0030
    FAX control PWB system error
    Processing with the fax software was disabled due to a hardware problem.
    Defective FAX control PWB.

    0070
    FAX control PWB incompatible detection Error
    Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted.
    FAX control PWB (The FAX PWB installed will not be the one designed for the machine.

    0100
    Backup memory device error
    EEPROM (Control PWB)

    0120
    MAC address data error
    For data in which the MAC address is invalid.
    EEPROM (Control PWB)

    0130
    Backup memory read/write error (main NAMD)
    Flash memory (Control PWB)

    0140
    Backup memory data error (main NAND)
    Flash memory (Control PWB)

    0150
    Engine PWB EEPROM error
    Detecting engine PWB EEPROM communication error.
    Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM.

    0170
    Billing counting error
    A checksum error is detected in the main and engine backup memories for the billing counters.
    Data damage of EEPROM. Defective PWB.

    0180
    Machine number mismatch
    Machine number of control does not match.
    Data damage of EEPROM.

    0600
    Expanded memory (DIMM) installing error
    The expansion memory modules (DIMM) are not correctly mounted.
    Improper installation expanded memory (DIMM).

    0610
    Expanded memory (DIMM) error
    The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly.
    Defective expanded memory (DIMM). Defective main PWB.

    0640
    Hard disk error
    The hard disk cannot be accessed.
    Defective hard disk. Defective main PWB.

    0830
    FAX control PWB flash program area checksum error
    A checksum error occurred with the program of the FAX control PWB.
    Defective FAX software. Defective FAX control PWB.

    0840
    Faults of RTC
    The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
    The battery is disconnected from the main PWB. Defective main PWB.

    0870
    FAX control PWB to main PWB high capacity data transfer error
    High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
    Improper installation FAX control PWB. Defective FAX control PWB or main PWB.

    0920
    Fax file system error
    The backup data is not retained for file system abnormality of flash memory of the FAX control PWB.
    Defective FAX control PWB.

    0930
    EEPROM bus error
    Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB.

    1010
    Lift motor error
    When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively.
    Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB.

    1020
    PF lift motor error (paper feeder 1)
    When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively.
    Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.

    1030
    PF lift motor error (paper feeder 2)
    When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively.
    Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.

    1500
    PF heater 1 high temperature error (paper feeder 1)
    A temperature higher than 75C/167F is detected.
    Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB.

    1510
    PF heater 2 high temperature error (paper feeder 1)
    A temperature higher than 75C/167F is detected.
    Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB.

    1520
    PF heater 1 high temperature error (paper feeder 2)
    A temperature higher than 75aC/167F is detected.
    Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB.

    1530
    PF heater 2 high temperature error (paper feeder 2)
    A temperature higher than 75C/167F is detected.
    Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB.

    1600
    PF heater 1 low temperature error (paper feeder 1)
    An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on.
    Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB.

    1610
    PF heater 2 low temperature error (paper feeder 1)
    An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on.
    Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB.

    1620
    PF heater 1 low temperature error (paper feeder 2)
    An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on.
    Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB.

    1630
    PF heater 2 low temperature error (paper feeder 2)
    An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on.
    Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB.

    1800
    Paper feeder communication error
    Communication error between engine PWB and optional paper feeder.
    Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB.

    2100
    Developing motor error
    The developing motor ready input is not given for 5 s during the main motor is ON.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB.

    2200
    Drum motor error
    The drum motor ready input is not given for 5 s during the drum motor is ON.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB.

    2330
    Fuser pressure release motor error
    When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB.

    2340
    Fuser pressure release motor time-out error
    When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB.

    2500
    Paper feed motor error
    The drum motor ready input is not given for 5 s during the paper feed motor is ON.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB.

    2600
    PF paper feed motor error (paper feeder 1)
    The drum motor ready input is not given for 2 s during the PF paper feed motor is ON.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB

    2610
    PF paper feed motor error (paper feeder 2)
    The drum motor ready input is not given for 2 s during the PF paper feed motor is ON.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB.

    2730
    Developing release motor error
    When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB.

    2740
    Developing release motor time-out error
    When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB.

    2820
    Fuser motor error
    The fuser motor ready input is not given for 5 s during the fuser motor is ON.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB.

    3100
    ISU home position error
    The home position is not correct when the power is turned on or at the start of copying using the table.
    Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB.

    3200
    Exposure lamp error
    When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
    Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB.

    3300
    AGC error
    After AGC, correct input is not obtained at CCD.
    Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB.

    3500
    Communication error between scanner and ASIC
    An error code is detected.
    Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB.

    4001
    Polygon motor KM error
    The polygon motor KM ready input is not given for 10 s during the polygon motor is ON.
    Defective connector cable or poor contact in the connector. Defective polygon motor KM. Defective engine PWB.

    4002
    Polygon motor CY error
    The polygon motor CY ready input is not given for 10 s during the polygon motor is ON.
    Defective connector cable or poor contact in the connector. Defective polygon motor CY. Defective engine PWB.

    4201
    Laser output error (black)
    The pin photo signal is not output from PD PWB K for one second while laser is emitted.
    Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB.

    4202
    Laser output error (cyan)
    The pin photo signal is not output from PD PWB C for one second while laser is emitted.
    Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB.

    4203
    Laser output error (magenta)
    The pin photo signal is not output from PD PWB M for one second while laser is emitted.
    Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB.

    4204
    Laser output error (yellow)
    The pin photo signal is not output from PD PWB Y for one second while laser is emitted.
    Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB.

    4600
    LSU cleaning motor error
    When the LSU cleaning motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB.

    4700
    VIDEO ASIC device error
    Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB.

    5301
    Broken cleaning lamp K wire
    When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB.

    5302
    Broken cleaning lamp C wire
    When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB.

    5303
    Broken cleaning lamp M wire
    When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB.

    5304
    Broken cleaning lamp Y wire
    When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB.

    6000
    Broken fuser heater wire
    The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s in warming up. The fuser temperature does not reach 100„aC/212„aF after the fuser heater has been turned on continuously for 30 s in warming up. The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s during printing.
    Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB.

    6020
    Abnormally high fuser thermistor temperature
    The fuser thermistor detects a temperature higher than 240C/464F. By the activation of the high temperature error detection circuit (230C/446F or more) of fuser thermistor, the illumination of fuser heater was forcibly turned off and 10 s has elapsed.
    Shorted fuser thermistor. Defective engine PWB.

    6030
    Broken fuser thermistor wire
    Input from fuser thermistor is 3 or less (A/D value) continuously for 1 s.
    Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB.

    6400
    Zero-cross signal error
    The zero-cross signal does not reach the engine PWB for more than 1 s.
    Defective connector cable or poor contact in the connector. Defective power source PWB or engine PWB

    7001
    Toner motor K error
    When the toner motor K is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB.

    7002
    Toner motor C error
    When the toner motor C is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB.

    7003
    Toner motor M error
    When the toner motor M is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB.

    7004
    Toner motor Y error
    When the toner motor Y is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals.
    Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB.

    7401
    Developing unit K noninstalling error
    No density detection signal is output from toner sensor K in developing unit K.
    Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB.

    7402
    Developing unit C noninstalling error
    No density detection signal is output from toner sensor C in developing unit C.
    Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB.

    7403
    Developing unit M noninstalling error
    No density detection signal is output from toner sensor M in developing unit M.
    Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB.

    7404
    Developing unit Y noninstalling error
    No density detection signal is output from toner sensor Y in developing unit Y.
    Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB.

    7411
    Drum unit K non- installing error
    The EEPROM of drum PWB K does not communicate normally.
    Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB.

    7412
    Drum unit C non- installing error
    The EEPROM of drum PWB C does not communicate normally.
    Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB.

    7413
    Drum unit M non- installing error
    The EEPROM of drum PWB M does not communicate normally.
    Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB.

    7414
    Drum unit Y non- installing error
    The EEPROM of drum PWB Y does not communicate normally.
    Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB.

    9500

    9520
    Contact the Service Administrative Division.

    9530
    Backup data error
    The serial number of the machine written on the EEPROM of the engine PWB differs with that is written on both the flash memory of the engine PWB and the EEPROM of the drum PWB as a backup.
    Replacing both the engine PWB and the drum unit at the same time.

    F000
    Main PWB — operation panel PWB communication error
    Defective main PWB. Defective operation panel PWB.

    F010
    Main PWB checksum error
    Defective main PWB

    F020
    Main PWB RAM checksum errors
    Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM).

    F040
    Main PWB — print engine communication error
    Defective main PWB. Defective engine PWB.

    F041
    Main PWB — scanner engine communication error
    Defective main PWB. Defective engine PWB.

    F050
    Print engine ROM checksum error
    Defective engine PWB.

    F051
    Scanner engine ROM checksum error
    Defective engine PWB.

    F278
    Power supply in drive system error
    Main power switch was turned off without using the power key, or a power failure has occurred.

    Описание ошибок:

    · Kyocera ошибка 7401 : XXXXXXX –
    ошибка блока проявки черного цвета.

    · Kyocera ошибка 7402 : XXXXXXX –
    ошибка блока проявки синего цвета.

    · Kyocera ошибка 7403 : XXXXXXX –
    ошибка блока проявки красного цвета.

    · Kyocera ошибка 7404 : XXXXXXX –
    ошибка блока проявки желтого цвета.

    В материале сегодняшнего дня поднимем тему возникновения и решения данной
    ошибки в цветных аппаратах Kyocera
    M5521 / P5021 / / P5026 / M5526 / FS-C5300DN
    / C5350DN / ECOSYS P6030 / FS-C5150DN / ECOSYS P6021 / С8525 / и других.

    В большинстве случаев, причиной возникновения данной ошибки, по мнению
    специалистов нашей компании, является использование некачественного тонера при
    заправке картриджей. В следствии этого нарушается баланс концентрации тонера –
    красящего порошка который переноситься на бумагу и девелопера — ферромагнитного
    порошка с помощью чего тонер переноситься на барабан. В некоторых случаях
    внутренние блоки забиваются так, что валы в них перестаю прокручиваться и
    ломаются.

    Для решения возникшей проблемы можно
    воспользоваться двумя вариантами:

         Первое решение — перезаправка качественным
    тонером или замена его оригинальным и покупка нового блока проявки.
      

    — Этот вариант приводит практически к стопроцентному решению проблемы, но
    требует значительных финансовых затрат. Блок проявки например DV-5230 (цвет
    синий) для аппаратов Kyocera
    M5521 / P5021 на момент написания материала
    стоит 8 500 рублей новый оригинальный тонер картридж от 4 000 тысяч. По самым
    скромным подсчётам получается двенадцать тысяч пятьсот рублей (без учета стоимости
    работ по замене). А если цвет не один – аппарат проще выкинуть ведь новый стоит
    двадцать, тридцать тысяч.

           Второе решение — восстановление
    блока проявки и перезаправка картриджа качественным тонером, что позволит
    значительно сэкономить.

    — для проведения работ аппарат службой доставки перемещается в нашу
    мастерскую.

    — специалисты компании производят необходимые работы.

    — стоимость работ доставкой за один цвет с не превышает трех тысяч рублей.

    — окончательный расчет производится после диагностики в нашем офисе.

    — срок выполнения работ – 24 часа (при наличии на складе расходных
    материалов).

    Особое внимание хотим обратить на использование в данных аппаратах
    картриджей
    Cactus, NVPrint, Colortek. Нам
    неоднократно приходилось ремонтировать аппараты после использования данных
    аналогов.

    Подводя итог всему вышесказанному отметим, что залог долгой работы
    оргтехники это грамотное обращение с ней, а так же использование качественных
    расходных материалов и своевременное обслуживание.

    Нужна консультация? Звоните!
    — 8-(812)-448-58-32

    Понравилась статья? Поделить с друзьями:
  • Ошибка 700037 siemens sinumerik 808d
  • Ошибка 7 фн неверные дата или время
  • Ошибка 7 при установке pixel experience
  • Ошибка 700035 sinumerik 828d
  • Ошибка 7004 case