Contents
-
Table of Contents
-
Bookmarks
Quick Links
Programat
P300
®
Operating Instructions
Related Manuals for Ivoclar Vivadent Programat P300
Summary of Contents for Ivoclar Vivadent Programat P300
-
Page 1
Programat P300 ® Operating Instructions… -
Page 3: Table Of Contents
Table of contents Views of the Furnace, List of Parts Introduction / Signs and Symbols Preface Introduction Notes regarding the Operating Instructions Safety First Indications Health and safety instructions Product Description Components Hazardous areas and safety equipment Functional description Accessories Installation and Initial Start-Up Unpacking and checking the contents Selecting the location…
-
Page 4: Views Of The Furnace, List Of Parts
List of parts Front view: Sealing surface Furnace head sealing ring Insulation Thermocouple Firing plate Display Frame plate QTK heating muffle Furnace housing 10 Keypad 11 On/Off switch 12 Heating element fuse 13 Vacuum pump fuse 14 Control unit fuse 15 Fuse holder 16 Power cord 17 Power socket…
-
Page 6
26 30… -
Page 7
Control unit: 70 Program key 71 ESC key 72 ENTER key 73 START key 74 Start LED 75 STOP key 76 + key 77 – key 78 Settings / information 79 Cursor key right 80 Cursor key left 81 Stand-by temperature 82 Closing time 83 Temperature increase 84 Holding temperature… -
Page 8: Introduction / Signs And Symbols
The signs and symbols in these Operating Instructions facilitate Furnace concerned: Thank you for having purchased the finding of important points Programat P300 the Programat P300. It is a and have the following Target group: state-of-the-art furnace for den- meanings: Dental technologists tal applications.
-
Page 9: Safety First
2. Safety first This chapter is especially important for personnel 2.1.1 who work with the Programat P300 or who have to carry out maintenance or repair work. This chapter must be read and the corresponding Risks and dangers instructions followed.
-
Page 10
2.1.6 2.1.12 Risk of crushing and burn hazard Risks and dangers Do not carry the furnace head by Never reach under the furnace the cooling tray. head with the hand or other parts of the body during operation, since there is a risk of crushing and a burn hazard. -
Page 11: Health And Safety Instructions
The heat insulation of the firing chamber in the – The user must especially become familiar with Programat P300 & P500 consists of ceramic the warnings and the operating conditions to fibres. After prolonged use of ceramic fibres at prevent injury to personnel or damage to temperatures of over 900 °C (1652 °F), silicogenic…
-
Page 12: Product Description
3. Product description 3.1 Components 3.2 Hazardous areas and safety equipment The Programat P300 comprises the following components: Description of the risk areas of the furnace: – Furnace base with electronic controls Hazardous area Art der Type of risk – Furnace head with firing…
-
Page 13: Installation And Initial Start-Up
Chapter 9) and transportation damage. If hazard. parts are damaged or missing, contact your local Ivoclar Vivadent Service Center. Remove the furnace components from their 4.3 Assembly packaging and place it on a suitable table. Please observe the instructions on the outer packaging.
-
Page 14
Place the cooling tray (34) on the frame plate (7). Make sure that the cooling tray (34) is correctly positioned on the frame plate (7). Secure the cooling tray (34) with the two screws (35) including the silicone rest (47). Step 2: Placing the firing plate (5) Place the firing plate (5) on the firing plate holder… -
Page 15
Step 3: Mounting the furnace head The complete furnace head is best mounted with the rear panel of the furnace pointing towards the user. Lift the furnace head with both hands (see picture) and carefully position it on the furnace head mounting (43). -
Page 16
Connect the vacuum pump plug with the vacuum pump socket (18). We recommend using only the VP3 easy or VP3 vacuum pumps from Ivoclar Vivadent, since these pumps are especially coordinated with the furnace. If other pumps are used, please observe and do not… -
Page 17: Initial Start-Up
4.4 Removing the furnace head Before the hood (36) is removed, the furnace has to be switched off and the power cord (16) disconnected from the power socket (17). 1. Loosen and remove the knurled screw (37) of the hood (36) 2.
-
Page 18: Operation And Configuration
5.1 Introduction to the operation – “Cogwheel” key Configuration and information (78) The Programat P300 is equipped with a graphical display (A) with After pressing the settings key (2 cogwheels), a selection (informa- backlighting. Moreover, the keypad features a parameter firing curve tion / settings) is displayed.
-
Page 19: Program Structure
5.3 Program structure 5.4 Adjustable parameters and possible value ranges The furnace offers three types of programs: Symbol Parameter Value range Value range a. Standard programs for Ivoclar Vivadent Program number P 1–100 materials b. Free programs Stand-by temperature 100–700 °C 212–1292 °F…
-
Page 20
Only after entry of the user code. The left key (<) can be used to navigate through the information ”Ivoclar Vivadent Only after entry of menu. The right key (>) is used to navigate through the settings and optimized the STD code. -
Page 21
5.5.2 Information Settings Display Short description Settings Display Short description Reset firing hours The firing hour count can be reset to 0. Serial number Serial number of the Only after entry of furnace the user code. Reset vacuum pump The operating hour hours count of the vacuum Software version… -
Page 22
5.6 Symbols in the display 5.7 Explanation of beeper tunes Symbol name Meaning Symbol Beeper description Explanation “One-stage Indicates that a Beeper lasting for approx. SELF-TEST has been completed program” conventional, one- 2 seconds with unchangeable stage program is “SELF-TEST signal” to indicate used the completion of the self-test. -
Page 23: Practical Use
6. Practical use Special variant: Conducting a one-stage program, in which only The operating procedure for the Programat P300 will be explained part of the holding time is fired with a vacuum (requirement: holding with the help of two examples: one standard and one individual temperature 1 = holding temperature 2).
-
Page 24: Firing Using An Individual Program
6.3 Firing using an individual program Step 1: Select a free program. Step 2: Press the desired parameter (e.g. temperature increase). The input mask appears. In the lower field, you will find information about the acceptable temperature range (min. and max.). This will facilitate the entry and prevents input errors.
-
Page 25: Maintenance, Cleaning And Diagnosis
Check the insulation for cracks and damages. If the insulation is worn down it has to Insulation (3) monthly be replaced by a certified Ivoclar Vivadent Service Center. Fine hairline cracks on the surface of the insulation are harmless and do not influence the function of the furnace in a negative fashion.
-
Page 26: Error Messages
A change in temperature of Press the ‘cog-wheel’ key (Settings/Information) ”+/-” 100 °C (180 °F) is possible in the Programat P300. Select – Vacuum pump test program: With this program, the vacuum performance of the furnace calibration program to activate the Firing plate (6) vacuum system can be automatically tested.
-
Page 27: What If
System Error in the heating system Check the heater fuse. If the fuse is O.K., contact your local Ivoclar Vivadent Service Center. System Heating muffle very old The heating muffle is very old. It is recommended to replace it. After the error message has been acknowledged, a firing program may still be started.
-
Page 28: Technical Malfunctions
Invalid checksum of the memory for firing group data — the firing group data are written to the internal firing group memory memory using the original values. System OT1 <> OT2 nein Error in the temperature measuring circuit! Contact your local Ivoclar Vivadent Service Center. plausibility check: **,*** OT1 = OT2 +/- 10°C System Temperature in the furnace Temperature in the furnace base is lower than 1 °C.
-
Page 29
Reading the serial number System Loading of the drivers failed 1500 Failure during loading the necessary drivers. The furnace is not ready. Contact your Ivoclar Vivadent Service Center. Behaviour of the furnace in case of error Furnace head opens when this error occurs. -
Page 30: Technical Malfunctions
Vivadent Service Center. Please refer to the addresses on the last page of these Operating Instructions. If repairs during the warranty period are not carried out by a certified Ivoclar Vivadent Service Center, the warranty will expire immediately. Please also refer to the corresponding warranty regulations.
-
Page 31: Product Specifications
500 mbar to 1060 mbar Power supply 110–120 V / 50–60 Hz 200–240 V / 50–60 Hz Use only original packaging of the Programat P300 together with the Overvoltage category II respective foam material for shipping purposes. Contamination level 2 Tolerated voltage fluctuations…
-
Page 32
10. Appendix 10.1 Program table Two program tables (°C / °F) are enclosed to these Operating Instruc- tions. If not, please contact your local Service Center. Important information The current program table is also available at: www.ivoclarvivadent.com The program tables can be downloaded from the Internet as PDF files. -
Page 33
Fax + 34 91 375 78 38 Tel. +86 21 5456 0776 www.ivoclarvivadent.com Ivoclar Vivadent Pty. Ltd. Fax. +86 21 6445 1561 Ivoclar Vivadent S.A. de C.V. 1 – 5 Overseas Drive www.ivoclarvivadent.com Av. Mazatlán No. 61, Piso 2 Ivoclar Vivadent AB P.O.
This chapter will help you to recognize malfunctions and take
appropriate measures or, if possible and acceptable, to perform
some simple repairs.
8.1 Error messages
In case of an error, the heater switches off for safety reasons.
The following error messages may be displayed:
Index Category Error
1
Entry
T < B
2
Entry
L > T
3
Entry
V2x <= V1x
4
Entry
V2x > Tx + 1°C
5
Entry
Incorrect values for V1x, V2x
6
System
Current temperature after
Start > Tx + 50 °C
7
System
Temperature in the firing
chamber > 410 °C at the
start of the calibration
program, i.e. too high
8
Entry
T2 < T1
9
System
Power failure > 10 s during
a firing program in progress
10
Entry
T1 > V12
11
Entry
vV set, but V2 is
missing or invalid
12
System
Error in the heating system
13
System
Heating muffle very old
14
System
Heating muffle defective
15
System
Temperature in the furnace
base is higher than 65 °C
16
Entry
T is > B + 200 °C at the
start of a firing program
17
System
Furnace head cannot
be initialized
18
System
The furnace head does not
reach the target position
19
System
Temperature > 1225°C (SW)
or > 1300°C (HW)
(8) EXCESS TEMPERATURE
20
System
The vacuum is not released
21
System
Necessary vacuum (xxxmbar)
is not reached within 1 min.
22
System
Write error in the
firing program memory
23
System
Read error in the firing
program memory
The furnace continuously checks
all functions during operation.
If an error is detected, the
respective error message is
displayed.
ERR
Conti-
Error Message Text
No.
nuation
possible
2
Enter a logical value for T
8
Enter a logical value for long-term cooling L
9
Enter a logical value for the vacuum-on temperature Vx1 or the vacuum-off temperature Vx2
10
Change either the vacuum values or the holding time T
11
Enter a logical value for V1x, V2x
13
Excess temperature! Program aborted, furnace head opens to allow the furnace to cool down.
*, **
14
Temperature too high for calibration; the furnace cools down! Start the program again later!
*
16
Enter a lower value for T1 or a higher value for T2.
17
A firing program in progress was interrupted for more than 10 s. The program cannot be continued!
18
Enter a lower value for T1 or a higher value for V12
19
Pre-vacuum activated! V2 must be higher than B.
20
no
Check the heater fuse. If the fuse is O.K., contact your local Ivoclar Vivadent Service Center.
**
23
The heating muffle is very old. It is recommended to replace it. After the error message has been
acknowledged, a firing program may still be started.
24
The condition of the muffle is so poor that is has to be replaced immediately.
25
The furnace base is too hot! Make sure that the air vents of the furnace are clean and unobstructed.
Maximum temperature 65 °C
26
Firing chamber too hot to start a firing program.
27
The furnace head cannot be moved to the final position. It might be blocked by an external mechanical
**, ***
source! If this is not the case, please contact your local Ivoclar Vivadent Service Center!
28
The furnace head does not open/close correctly. The furnace head was manually moved or is obstructed.
**
The furnace head must only be moved using the keys intended for this purpose!
29
no
Excess temperature! The temperature in the furnace head by far exceeds the acceptable temperature
*, **,
range (maximum temperature 1200 °C).
***
32
nein
The vacuum cannot be released. The vacuum valve might be dirty or stuck. Please contact your service
**
technicians.
33
The vacuum cannot be established. Check the seal of the firing chamber, vacuum hose, vacuum pump,
pump fuse.
43
Error while saving firing program data to the internal memory.