Ошибка 12030 hyper v

These are the full errors from the Administrative events

The description for Event ID 12140 from source Microsoft-Windows-Hyper-V-SynthStor cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event:

New Virtual Machine

6CC98392-976B-478C-90E9-86BAE7AC027D

C:\iso\SW_DVD9_Windows_Svr_Std_and_DataCtr_2012_R2_64Bit_English_-4_MLF_X19-82891.ISO

%%2147943792

7864368

80070570

Hyper-V Virtual Machine Management service

The handle is invalid

The description for Event ID 12010 from source Microsoft-Windows-Hyper-V-Worker cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event:

New Virtual Machine

6CC98392-976B-478C-90E9-86BAE7AC027D

Synthetic SCSI Controller

%%2147943792

0x80070570

4DC49261-3A81-401F-98DB-974C89B3DE3B

The handle is invalid

The description for Event ID 12030 from source Microsoft-Windows-Hyper-V-Worker cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event:

New Virtual Machine

6CC98392-976B-478C-90E9-86BAE7AC027D

The handle is invalid

  • Remove From My Forums

 locked

Не запускаются виртуальные машины

  • Вопрос

  • Хост-машина:
    Server 2008 x64 с Hyper-V

    Поначалу всё работало. Сейчас — нет: создаю любую виртуальную машину, на этапе подключения/создания жесткого диска на IDE выдаётся ошибка:

    Не похоже, что проблема с доступом из-за некорректных прав к папке с жестким дисками, потому что подобная ошибка происходит и при монтировании пустого виртуального CD-ROM’а.

    Что на самом деле значит эта ошибка? Как её решить?
    Я пробовал переустановить Hyper-V, но оказалось, что его конфигурация сохраняется. Как сбросить его настройки на начальное состояние?

Ответы

    • Помечено в качестве ответа

      13 апреля 2009 г. 20:53

Dear Hyper-v gurus

I am trying to start up a new virtual machine created with an existing virtual hard drive.

When i try to power it on , it gives me the following message:

An error occured while attempting to start the selected virtual machine(s):
*********** failed to change state.

I checked the logs and i have the following error logs:

12140

The description for Event ID 12140 from source Microsoft-Windows-Hyper-V-EmulatedStor cannot be found. Either the component that raises this event is not installed on your local computer or the
installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event:

AX2012 RDS DEV

735ABDE2-3815-484A-BB73-2683A2F2BE9A

F:\Hyper-V Disks\AX2012 RDS DEV\HV_AX2012.vhdx

%%2147943065

7864368

80070299

The locale specific resource for the desired message is not present

The description for Event ID 12140 from source Microsoft-Windows-Hyper-V-EmulatedStor cannot be found. Either the component that raises this event is not installed on your local computer or the
installation is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event:

AX2012 RDS DEV

735ABDE2-3815-484A-BB73-2683A2F2BE9A

F:\Hyper-V Disks\AX2012 RDS DEV\HV_AX2012.vhdx

%%2147943065

7864368

80070299

IDE/ATAPI

The locale specific resource for the desired message is not present

12010

The description for Event ID 12010 from source Microsoft-Windows-Hyper-V-Worker cannot be found. Either the component that raises this event is not installed on your local computer or the installation
is corrupted. You can install or repair the component on the local computer.

If the event originated on another computer, the display information had to be saved with the event.

The following information was included with the event:

AX2012 RDS DEV

735ABDE2-3815-484A-BB73-2683A2F2BE9A

Microsoft Emulated IDE Controller

%%2147943065

0x80070299

83F8638B-8DCA-4152-9EDA-2CA8B33039B4

The locale specific resource for the desired message is not present

12030

‘AX2012 RDS DEV’ failed to start. (Virtual machine ID 735ABDE2-3815-484A-BB73-2683A2F2BE9A)

Any help would be appreciated :)

EDIT:

The OS on the virtual machine host is windows 10:
The virtual machine’s OS is windows server 2012 R2

  • Edited by

    Friday, April 28, 2017 12:23 PM

Had a few Hyper-V host systems today that after rebooting failed to restart the VMs that were set to auto-restart. No updates had been installed – the reboots were due to power environment changes.

Attempting to restart them from Hyper-V Manager simply resulted in the VM status quickly changing from Off to Starting then back to Off.

Digging though the Event Logs (Applications and Service Logs | Microsoft | Windows | Hyper-V-Worker | Admin) resulted in this:

Log Name:      Microsoft-Windows-Hyper-V-Worker-Admin
Source:        Microsoft-Windows-Hyper-V-Worker
Date:          4/02/2013 1:42:57 PM
Event ID:      12140
Description:
'hyper-vm1': Failed to open attachment 'E:\hyper-v\VHDs\hyper-vm1.vhd'. Error: 'A device attached to the system is not functioning.' (0x8007001F). (Virtual machine ID 9F3157AA-4875-45C5-BAE4-3D7D5C432B8A)

Log Name:      Microsoft-Windows-Hyper-V-Worker-Admin
Source:        Microsoft-Windows-Hyper-V-Worker
Date:          4/02/2013 1:42:57 PM
Event ID:      12010
Description:
'hyper-vm1' Microsoft Emulated IDE Controller (Instance ID {83F8638B-8DCA-4152-9EDA-2CA8B33039B4}): Failed to Power on with Error 'A device attached to the system is not functioning.' (0x8007001F). (Virtual machine ID 9F3157AA-4875-45C5-BAE4-3D7D5C432B8A)

Log Name:      Microsoft-Windows-Hyper-V-Worker-Admin
Source:        Microsoft-Windows-Hyper-V-Worker
Date:          4/02/2013 1:42:57 PM
Event ID:      12030
Description:
'hyper-vm1' failed to start. (Virtual machine ID 9F3157AA-4875-45C5-BAE4-3D7D5C432B8A)

And this one from Hyper-V-VMMS/Admin (Applications and Service Logs | Microsoft | Windows | Hyper-V-VMMS | Admin):

Log Name:      Microsoft-Windows-Hyper-V-VMMS-Admin
Source:        Microsoft-Windows-Hyper-V-VMMS
Date:          4/02/2013 1:37:05 PM
Event ID:      14098
Description:
'Storage Virtualization Service Provider' driver required by the Virtual Machine Management service is not installed or is disabled. Check your settings or try reinstalling the Hyper-V role.

It was this second one that helped me track down the problem. I subsequently found Microsoft Knowledgebase Article 2013544 which listed a similar scenario and recommended changing the FSDepends driver from Manual start to Boot start as follows:

  • Start Registry Editor
  • Navigate to the following registry key: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\FsDepends
  • Under the FsDepends key, change REG_DWORD value “Start” from 3 to 0
  • Restart the server

The reason is supposedly due to a timing issue between FSDepends.sys (nested volume dependency management driver) and VHDMP.sys (VHD parser and dependency property provider driver), typically triggered by third party backup programs that load tape drivers. This wasn’t the case in my situation, but changing FsDepends from Manual start to Boot start ended up resolving my VM startup problem.

bud…@yandex.ru

unread,

Mar 18, 2015, 11:18:43 AM3/18/15

to sc-sec…@googlegroups.com

После установки сервера безопасности SecretNet Версия 7.0.460.16 под WinServer 2008R2 после запуска программы управления внизу появляется красная строка с сообщением «Ошибка: Сбой в работе сети. Код — 12030 (0x2efe)».
Также обратил внимание на то, что не записываются логи…остался лог после установки СБ, но он не обновляется при запуске программы управления.

Vadim V

unread,

Mar 18, 2015, 4:41:07 PM3/18/15

to sc-sec…@googlegroups.com

Добрый день.

Уточните, соединяется ли при этом ПУ с сервером?

Если нет, то проблема вероятнее всего в конфликте портов.

Сетевое соединение с сервером безопасности осуществляется через порт 443
(стандартный порт SSL). На стороне клиента порт выбирается динамически. На
стороне сервера возможны следующие конфликты использования портов:

·        если функционируют службы обновлений сервера SQL, ПО Apache,
Skype, которые используют тот же порт. Сведения о привязке портов к процессам
можно получить с помощью команды «netstat –aon»;

·        если сервер
безопасности функционирует на компьютере под управлением ОС Windows Server 2012
R2 с включенным компонентом Work Folders для роли File and Storage Services. В
этом случае для обеспечения соединения с сервером или остановите работу службы
SyncShareSvc или смените порт, используемый по умолчанию компонентом Work
Folders (см. https://blogs.technet.com/b/filecab/archive/2013/10/15/windows-server-2012-r2-resolving-port-conflict-with-iis-websites-and-work-folders.aspx).

среда, 18 марта 2015 г., 11:18:43 UTC+3 пользователь bud…@yandex.ru написал:

Евгений Мухин

unread,

Mar 19, 2015, 12:03:41 AM3/19/15

to sc-sec…@googlegroups.com

Если вы смотрите Логи в файле snTrace.log будут записываться при включении логирования

в папке Tools\Infosec\Trace -есть рег-файл для этого — применяется после перезагрузки.

среда, 18 марта 2015 г., 12:18:43 UTC+4 пользователь bud…@yandex.ru написал:

bud…@yandex.ru

unread,

Mar 20, 2015, 4:12:21 PM3/20/15

to sc-sec…@googlegroups.com

1. ПУ не соединяется с СБ, порт 443 занят только процессом system (apache,sql,skype не установлены…сервер поставили с нуля, на нём вообще кроме oracle и СБ ничего нет)
2. За логирование — спасибо, включил

Vadim V

unread,

Mar 20, 2015, 4:35:15 PM3/20/15

to sc-sec…@googlegroups.com

Добрый день.

В таком случае потребуется дополнительный анализ Вашей проблемы. Просим Вас обратиться в техническую поддержку, на ящик sup…@securitycode.ru

пятница, 20 марта 2015 г., 16:12:21 UTC+3 пользователь bud…@yandex.ru написал:

Евгений Мухин

unread,

Mar 21, 2015, 10:41:21 PM3/21/15

to sc-sec…@googlegroups.com

Можно проверить что сервер пингуется по имени, — если в ответах на пинг появляется «::1»  обходное решение :) — прописать его имя и ip-адрес в файл etc\hosts

проверить telnet на 443,  сертификат на IIS и виндовые журналы ISS (в виндовых журналах приложений покопаться)

 ну а так конечно тех поддержка всегда поможет

пятница, 20 марта 2015 г., 17:12:21 UTC+4 пользователь bud…@yandex.ru написал:

Atamasov Mikhail

unread,

Apr 27, 2015, 8:56:17 AM4/27/15

to sc-sec…@googlegroups.com

среда, 18 марта 2015 г., 14:18:43 UTC+6 пользователь bud…@yandex.ru написал:

> После установки сервера безопасности SecretNet Версия 7.0.460.16 под WinServer 2008R2 после запуска программы управления внизу появляется красная строка с сообщением «Ошибка: Сбой в работе сети. Код — 12030 (0x2efe)».
> Также обратил внимание на то, что не записываются логи…остался лог после установки СБ, но он не обновляется при запуске программы управления.

Добрый день.
Подскажите, решилась ли проблема? Если да, то очень хотелось бы узнать каким образом, т.к. так же наблюдается подобная картина.

bud…@yandex.ru

unread,

Apr 27, 2015, 11:06:31 AM4/27/15

to sc-sec…@googlegroups.com

Да проблема решилась…только установкой СБ на Hyper-V на том же сервере