Ошибка 1030 citrix

Если не удается подключиться к ферме XenDesktop и вылезает ошибка со статусом 1030, причин может быть несколько:

1. Самая вероятная — некорректно настроены STA на SecureGateway и в настройках SecureAccess в парамерах Web Interface. STA должны быть одни и те же.

2. Второй возможный вариант — шлюз SecureGateway или NetScaler не может получить доступ к подключаемой машине по портам TCP 1494 и TCP 2598. Виноват файервол на машине к которой производится подключение.

3. Третий вариант — на Web Interface некорректно настроен Secure Access и в параметрах подключения ICA он выдает локальный адрес машины VDI, вместо адреса шлюза SecureGateway.

  • citrix/citrix-xendesktop-connection-to-desktops-failed-with-status-1030.txt
  • Last modified: 2019/02/11 09:13
  • by 127.0.0.1


Log In

CTX135009


{{tooltipText}}

Article
|


Connectivity

|

{{likeCount}} found this helpful
|

Created:
{{articleFormattedCreatedDate}}

|
Modified:
{{articleFormattedModifiedDate}}

Symptoms or Error

When trying to start a XenDesktop session, it fails with the following error message:

«The connection to ‘Windows 7 Desktop’ failed with status 1030»

Note: The 1030 message is a generic network error indicating that connection has failed.


Solution

As Provisioning Services works over IP, the DNS entries are not required for any target machines to stream successfully.

To resolve this issue, complete the following procedure:

  1. Delete any provisioned target machine DNS records from the DNS server that contains private IP address.

  2. Start the provisioned target machine in Private mode.

  3. Clear Register this connection’s addresses in DNS on the provisioned streaming NIC only, as displayed in the following screen shot.

    User-added image

  1. Run ipconfig /flushDNS to remove any old DNS entries on the target and the Delivery Controller (Controller).

    Ensure that the Controller is reachable from the provisioned target on the first NIC address and same the other way round with the correct IP address.

  1. Shut down the provisioned target and return to Standard Image mode from Private Image mode.

The provisioned targets must now register using the correct IP address of the first NIC.


Problem Cause

After analyzing the issue, it was observed that the launch.ica file for the XenDesktop session appeared to contain a non-routable address. After verifying with the customer, it was confirmed that the address belongs to a secondary NIC on XenDesktop virtual machine that is used for streaming the image using Citrix Provisioning Services.

This happened because the secondary NIC with a private address on the provisioned target machine was registered with the DNS server.


Almost everybody has struggled with the now infamous Error 1030 (The connection to “ApplicationName” failed with status (1030)) when connecting with Citrix Receiver for Windows to XenDesktop through NetScaler and StoreFront. There even is an whole armada of articles available out there, totally dedicating their content to troubleshooting this quite generic network error indicating that the connection has failed. Just google it!

error_1030_4

The solution to this error? Well, it depends…

The most common issues based on experience are:

  • required ports blocked in your firewall, especially TCP 1494 and TCP 2598
  • STA configuration mismatch in NetScaler and StoreFront
  • NetScaler licensing issues (Basic Mode vs SmartAccess Mode)
  • DNS name resolution issues
  • Proxy configuration issues
  • SSL issues regarding StoreFront’s server certificate being issued by a private CA that is not trusted by the endpoint
  • launch.ica file issues

As Carl Stalhood once pointed out here:

1030 usually means one of the following:

  • STAs are invalid. STAs on StoreFront don’t match the STAs on the NetScaler Gateway
  • Firewall is blocking TCP 1494 and TCP 2598 from the NetScaler SNIP (not the VIP) to every internal VDA
  • StoreFront did not recognize it as a Gateway connection and is giving out the internal IP of the VDA instead of the gateway address

You can look in the ICA file to make sure it’s trying to use the  Gateway: http://support.citrix.com/article/CTX115304

In my case it turned out that I received the 1030 error as soon as I added my AppController’s STA URL to the StoreFront configuration under the “NetScaler Gateway” node in the “Secure Ticket Authority” option. As far as I know this is required for a XenMobile implementation but as for me it suffices adding the AppController STA URL in NetScaler. This behaviour can be reproduced at any time:

error_1030_1

To get a more detailed error description when connecting, try to disable Desktop Viewer Toolbar as per CTX131867:

error_1030_2

The StoreFront Services Receiver for Web configuration can be modified as follows to disable Desktop Viewer Toolbar:

  1. Log on to StoreFront Services server
  2. Open C:\inetpub\wwwroot\Citrix\<StoreWeb>\web.config with Notepad
  3. Change showDesktopViewer=”false”
  4. Save the changes

After adjusting the web.config file I received the following error instead of the generic 1030 message:

error_1030_3

This error message pointed me in the direction of my AppController as it displayed its STA ID. Upon investigating I found the aforementioned misconfiguration in StoreFront’s NetScaler Gateway settings.

Furthermore you could disable Session Reliability (equals to Common Gateway Protocol (CGP) running on Port 2598) in StoreFront in order to receive a more meaningful error message:

  1. Log on to StoreFront Services server
  2. Open StoreFront MMC
  3. Navigate to NetScaler Gateway node
  4. Select your NetScaler Gateway in the middle pane
  5. Click Secure Ticket Authority in the right pane
  6. Disable checkbox for Enable Session Reliability and click OK

disable_cgp

Another time the firewall was blocking ports TCP 80, 443, 1494, and TCP 2598 from the NetScaler SNIP (not the VIP) to my internal VDA, i.e. Citrix Workers. As soon as the corresponding firewall rules had been adjusted it worked.

2015-10-20 Update:
Once again I had problems pointing to DNS name resolution issues, i.e. you have to ensure that besides the aforementioned ports necessary for smooth communication you have to consider DNS. All Controllers, Workers, and StoreFront servers need to be resolvable by NetBIOS names and FQDN from a client point of view. A client utilized access to XenApp published resources through StoreFront from another network and Active Directory Domain by connecting both networks via VPN. All required ports were available, but we missed to enable a successful name resolution mechanism for client computers in the source domain connecting to Citrix resources in the target domain. Consider multiple DNS Suffices and DNS Suffix Search Lists as well.

2016-07-04 Update:
In case you’re using a Proxy Server in your Environment (or con’t use any Proxy alltogether): keep in mind that wrong Proxy Settings in WebInterface and/or launch.ica can cause an Error 1030 as well. Prior to StoreFront v2.x there was no GUI Option to edit any client-side Proxy Settings for Citrix Receiver, thus leaving you with adjusting the default.ica configuration file. For StoreFront v3.x onwards read this thread from Citrix Discussions. You have to set ProxyType=None in both the [WFClient] and [Application] sections of default.ica configuration file. With WebInterface v5.x you can adjust client-side Proxy Settings in the WebInterface Management Console by highlighting your XenApp and/or XenApp Services Site and chosing Client-Side Proxy in the Action pane (for details check out p153 of the WebInterface 5.4 Documentation [PDF]). And have a look at David’s article on this issue as well.

As you can see there is no all encompassing solution to this error, instead leaving you to further investigate and keep the aforementioned hints in mind.

Further reading:

  • CTX133773 – Troubleshooting 1030 Error on Windows 7 Image
  • CTX135009 – Error: The connection to Windows Desktop failed with status 1030
  • CTX132723 – Case Study: Error 1030 Reported during Logon Attempt to XenDesktop Session
  • CTX131867 – Desktop Viewer Toolbar Affects XenApp Published Desktops Using StoreFront Services Receiver for Web
  • CTX115304 – How to Save the Launch.ica File to a Client Computer
  • CTX137254 – Error 1030 on External Access with Proxy
  • Citrix Discussions – 1030 or 1110 error when accessing the desktop via NetScaler
  • Citrix Discussions – The Connection to desktops failed with status (1030)
  • David R Figueroa – StoreFront & 1030 Errors
  • Citrix Error: The connection to *** failed with status 1030
  • The connection to “Desktop” failed with status 1030
  • Citrix Discussions – StoreFront Client-Side Proxy Settings

Step 1 – Solve Mypc Error 1030

Is Mypc Error 1030 appearing? Would you like to safely and quickly eliminate failed with status which additionally can lead to a blue screen of death?

When you manually edit your Windows Registry trying to take away the invalid the connection to failed with status 1030 citrix desktop viewer keys you’re taking a authentic chance. Unless you’ve got been adequately trained and experienced you’re in danger of disabling your computer system from working at all. You could bring about irreversible injury to your whole operating system. As very little as just 1 misplaced comma can preserve your Pc from even booting every one of the way by!

Troubleshooting error 1030 citrix access gateway Windows XP, Vista, 7, 8 & 10

Simply because this chance is so higher, we hugely suggest that you make use of a trusted registry cleaner plan like CCleaner (Microsoft Gold Partner Licensed). This system will scan and then fix any Mypc Error 1030 complications.

Registry cleaners automate the entire procedure of finding invalid registry entries and missing file references (including the Mypc error) likewise as any broken hyperlinks inside of your registry.

Issue with unknown client error 0 citrix

Backups are made immediately prior to each and every scan providing you with the choice of undoing any changes with just one click. This protects you against doable damaging your pc. Another advantage to these registry cleaners is that repaired registry errors will strengthen the speed and performance of one’s procedure drastically.

  • http://discussions.citrix.com/topic/255945-desktop-viewer-error-1030-when-connecting-to-desktop-group/
  • http://www.brianmadden.com/forums/t/42959.aspx
  • http://support.citrix.com/article/CTX124143
  • http://discussions.citrix.com/topic/347286-the-connection-to-desktops-failed-with-status-1030/

Cautionary Note: Yet again, for those who are not an state-of-the-art consumer it’s very encouraged that you simply refrain from editing your Windows Registry manually. If you make even the smallest error within the Registry Editor it can result in you some serious issues that may even call for a brand new set up of Windows. Not all difficulties attributable to incorrect Registry Editor use are solvable.

Fixed: citrix 1030 error xenapp

Symptoms of Mypc Error 1030
“Mypc Error 1030” appears and crashes the energetic method window.
Your Personal computer routinely crashes with Mypc Error 1030 when running the exact same system.
“Mypc Error 1030” is shown.
Windows operates sluggishly and responds little by little to mouse or keyboard input.
Your computer periodically “freezes” for the number of seconds in a time.

Will cause of Mypc Error 1030

Corrupt obtain or incomplete set up of Windows Operating System software program.

Corruption in Windows registry from a new Windows Operating System-related application adjust (install or uninstall).

Virus or malware infection which has corrupted Windows method documents or Windows Operating System-related application data files.

Another method maliciously or mistakenly deleted Windows Operating System-related files.

Mistakes this sort of as “Mypc Error 1030” can be brought about by several different elements, so it really is important that you troubleshoot every of the achievable brings about to forestall it from recurring.

Simply click the beginning button.
Variety “command” inside the lookup box… Will not hit ENTER nonetheless!
Although keeping CTRL-Shift in your keyboard, hit ENTER.
You’re going to be prompted that has a authorization dialog box.
Click on Of course.
A black box will open having a blinking cursor.
Variety “regedit” and hit ENTER.
Within the Registry Editor, choose the the connection to failed with status 1030 citrix desktop viewer connected key (eg. Windows Operating System) you wish to back again up.
Within the File menu, choose Export.
Inside the Preserve In list, pick out the folder in which you wish to save the Windows Operating System backup key.
Inside the File Title box, sort a reputation for the backup file, these types of as “Windows Operating System Backup”.
From the Export Vary box, ensure that “Selected branch” is selected.
Click on Help you save.
The file is then saved by using a .reg file extension.
You now use a backup within your error 1030 citrix access gateway related registry entry.

Solution to your the connection to desktop failed with status 1110 problem

There are actually some manual registry editing measures that can not be talked about in this article due to the high chance involved for your laptop or computer method. If you want to understand more then check out the links below.

Additional Measures:

One. Conduct a Thorough Malware Scan

There’s a probability the 1030 Error Mypc error is relevant to some variety of walware infection. These infections are malicious and ready to corrupt or damage and possibly even delete your ActiveX Control Error files. Also, it’s attainable that your Mypc Error 1030 is actually connected to some element of that malicious plan itself.

2. Clean failed with status 1030 citrix xenapp Disk Cleanup

The a lot more you employ your computer the extra it accumulates junk files. This comes from surfing, downloading packages, and any sort of usual computer system use. When you don’t clean the junk out occasionally and keep your program clean, it could turn into clogged and respond slowly. That is when you can encounter an Mypc error because of possible conflicts or from overloading your hard drive.

Once you clean up these types of files using Disk Cleanup it could not just remedy Mypc Error 1030, but could also create a dramatic change in the computer’s efficiency.

Tip: While ‘Disk Cleanup’ is definitely an excellent built-in tool, it even now will not completely clean up failed with discovered on your PC. There are numerous programs like Chrome, Firefox, Microsoft Office and more, that cannot be cleaned with ‘Disk Cleanup’.

Since the Disk Cleanup on Windows has its shortcomings it is extremely encouraged that you use a specialized sort of challenging drive cleanup and privacy safety application like CCleaner. This system can clean up your full pc. If you run this plan after each day (it could be set up to run instantly) you are able to be assured that your Pc is generally clean, often operating speedy, and always absolutely free of any 1030 error associated with your temporary files.

How Disk Cleanup can help the connection to desktop failed with status 0

1. Click your ‘Start’ Button.
2. Style ‘Command’ into your search box. (no ‘enter’ yet)
3. When holding down in your ‘CTRL-SHIFT’ important go ahead and hit ‘Enter’.
4. You will see a ‘permission dialogue’ box.
5. Click ‘Yes’
6. You will see a black box open up plus a blinking cursor.
7. Variety in ‘cleanmgr’. Hit ‘Enter’.
8. Now Disk Cleanup will start calculating the amount of occupied disk space you will be able to reclaim.
9. Now a ‘Disk Cleanup dialogue box’ seems. There will be a series of checkboxes for you personally to pick. Generally it will likely be the ‘Temporary Files’ that consider up the vast majority of your disk area.
10. Verify the boxes that you want cleaned. Click ‘OK’.

How to repair the connection to failed with status (unknown client error 0)

3. System Restore can also be a worthwhile device if you ever get stuck and just desire to get back to a time when your computer system was working ideal. It will work without affecting your pics, paperwork, or other crucial information. You can discover this option with your User interface.

failed with

Manufacturer

Device

Operating System


Mypc Error 1030


5 out of
5

based on
44 ratings.

In most situation, if you get this error, it means that there are some configuration errors in your Citrix environment. You can refer to below Citrix article for more information.

https://support.citrix.com/article/CTX124143

But, this week when we tried to renewal our netscaler certificate, we got a problem that:
1. Windows Machines works well with the new certificate. End users can start their VDIs with out any problem;
2. Windows Thin client which is running Windows Embedded XP can’t start VDI. They always got the error code’1030′
3. Some Linux thin client users can start their VDI, while some of them can’t. For who can’t start their VDI they got an error message said that S’SSL error’

Finally, after two days investigation, we fixed this issue.

1. Use Symantec SSL toolbox to scan the certificate installed on our server. We found below error message
SSL

It means that for some old client, they may get problem without the chain. So download the chain and put it into the certificate on Netscaler.

2. After we fixed the chain issue, our thin client still can’t connect. And we found that for the thin client which is running Citrix Receiver 13.1, it can connect. And then we checked Citrix Receiver version changelog and we found

New features in this release

    Native Smartcard authentication to StoreFront
    Session Reliability for robust HDX connection
    SHA-2 encryption for enhanced security
    Improved 64-bit packaging to enable access from 64-bit Linux distributions


https://www.citrix.com/downloads/citrix-receiver/linux/receiver-for-linux-131.html

Well, that’s the key point. For thin client have, they are still using citrix online plugin 11.2 or Citrix Receiver 13.0 for Linux.
So we changed our certificate to SHA1, and all works.

The next step is to upgrade Citrix Receiver to the latest version on all Thin Client and then deprecation SHA-1 certificate and moving to SHA-2.

Понравилась статья? Поделить с друзьями:
  • Ошибка 104 volvo s60
  • Ошибка 103 фотошоп
  • Ошибка 104 safari
  • Ошибка 104 delphi
  • Ошибка 103 при установке драйверов