Cyclone Fanuc OT-B lathe error 1008,1017 & 1032

My name is Bob and I am new to your forum, thanks to admin for letting me join. I am the owner of a 1989 Denford Cyclone. This is ex college, and has not run for at least the last 9 years since I have been there.

The machine has an error fault on startup, so I am hoping to try to resolve this.

When I fire up the Cyclone, the first screen on the Fanuc says, «not ready»
If I go into the alarms screen on the Fanuc there are 3 error codes.

1008 Spindle drive fault
1017 Spindle drive overheat
1032 Drive transformer overheat.

I need to simplify the meaning of this, albeit it does sound fairly obvious, but I want to know what and where to look to solve the problem.

Inside the big black box that is the power supply, I see one of the breakers is at the off position. I have identified this using a drawing downloaded from this forum as the spindle drive breaker.

I hasten to add the drawing is for a Cyclone OT-B and the layout is not entirly the same as my box, as I do not recall having a spindle motor fan breaker as is shown in this drawing.

Turning this breaker on does nothing, so this is where I need assistance if possible, and the correct power supply drawing please.
Bob


User avatar

bradders

CNC Guru
CNC Guru
Posts: 1251
Joined: Mon 13 Feb , 2006 12:35 pm
Location: Brighouse, England
Contact:

Post

by bradders » Wed 04 Feb , 2009 9:59 am


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Wed 04 Feb , 2009 21:14 pm

Many thanks, I’m sure if I study this I may well find the a way of sorting the problem. One question, can all the parameters be upload via the serial port as with a Bridgeport mill and heidenhain controller? If they can, are they available to download from a site somewhere?

I realised I should have put my model number/ serial number on the original post. Will do this soon.
Bob


User avatar

Lone_Ranger

CNC Expert
CNC Expert
Posts: 220
Joined: Mon 01 Oct , 2007 15:23 pm
Contact:

Post

by Lone_Ranger » Thu 05 Feb , 2009 0:42 am

Emimec wrote:Many thanks, I’m sure if I study this I may well find the a way of sorting the problem. One question, can all the parameters be upload via the serial port as with a Bridgeport mill and heidenhain controller? If they can, are they available to download from a site somewhere?

I realised I should have put my model number/ serial number on the original post. Will do this soon.
Bob

Hi Bob

Yes, they can be uploaded and downloaded via RS232, but first thing you need to do is put new batteries in if you haven`t already done so because if they are done then even if you reload all the parameters as soon as you switch it off you will lose them again, needs the batteries.

I have 2 Cyclones, one is OT-B 1989 and the other is OT-C 1990, you can tell which one it is from the layout of the buttons on the Fanuc control, they look identical at first but where the operational buttons are Auto, Cycle Start etc and where the «Mode» buttons like Home, Jog, Axis are there is a plastic «seperator» between the sets of buttons on the OT-B but it is not there on the OT-C.
The other way to tell is to look in the control cabinet on the back of the machine and look at the top of the «Motherboard» which is quite small in the OT-C and has at least 3 «daughter» boards and has OT-C printed on it along the top.

I downloaded all my Parameters from both machines so I could maybe help out with that, the only issue might be the «900» parameters as I don`t have the ones for the «soft keys» or the «Graphics» but I also have some that are changed to allow the names of programs to show on screen, also allows up to 32 offsets now!! Don`t know what memory you have but both of mine only had 4Kb which is not much use, the OT-C one I have upgraded to 128Kb so now I can keep all my programs in the machine and call up as needed which is great!!

If you need to speak to me I am on 01254 389120

Regards
Rob


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Thu 05 Feb , 2009 8:10 am

Many thanks Rob.
I am very new to the Cyclone lathe, as you probably gathered.
On Saturday I will study close up my machines controller, and using your guide, identify the model.

I was hoping this machine could replace my old plugboard Emi-Mec auto lathe, but sadly it came with no chuck or collets, let alone this controller problem.

I will follow all the advice recieved so far, and study the manuals I have and were sent on a previous post.

I’ll turn it on first, and then change the batteries, then check if I have lost the parameters.

Assuming I have, I will try to find a pin configuration for the RS232 link and make up a cable, then will no doubt need to come back to you to request the address of where to download the set of parameters.

If they are not lost, I have a lot of reading to do over the weekend !

Kind Regards
Bob Plume


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Thu 05 Feb , 2009 9:13 am

Serial Number CYO 3118 B

Date 23/1/89

PLC 2.036I ( the zero has a / across it )


User avatar

Lone_Ranger

CNC Expert
CNC Expert
Posts: 220
Joined: Mon 01 Oct , 2007 15:23 pm
Contact:

Post

by Lone_Ranger » Thu 05 Feb , 2009 9:40 am

.

Hi Bob

Once you get the Cyclone up and running you will wonder how you ever managed without it!!

One other small thing, if you appear to have a turret problem it may just need 2 of the phases swapping, the turret is «phase dependent».

Link to page on this Forum for RS232 info, this is all works spot on.

viewtopic.php?t=1179&highlight=fanuc+rs232

Other useful Parameter info including some «900» parameters as Posted by «Bradders».

N0535P 60
N0536P 40
N0537P 0

N0700P 8000
N0701P 6000
N0702P 0
N0703P 0
N0704P 168000
N0705P 165000
N0706P 0
N0707P 0
N0708P 146000

N0900P 00111000
N0901P 11100000
N0902P 00000100
N0903P 00000100
N0904P 00000000
N0905P 00000001
N0906P 00000001
N0907P 01010000
N0908P 00000000
N0909P 01000000

The «900» parameters don`t upload/download with the rest of the Parameters, you have to do them by hand, but there are only 20 of them so doesn`t toke long!!

Regards
Rob

P.S. I will check the PLC Software versions I have later, one may be the same as yours, I`ll get back to you on that one.

.


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Thu 05 Feb , 2009 19:32 pm

Hi
Many thanks for the link and further information.
The RS232 configuration looks exactly the same as for the Bridgeport/Heidenhain.
A thought crossed my mind, what software is used to perfom the download/uploads?

For the Bridgeport I use the freely available TNCremont, or server program. I suppose i could try this, or even have a go on hyperterminal.


User avatar

Lone_Ranger

CNC Expert
CNC Expert
Posts: 220
Joined: Mon 01 Oct , 2007 15:23 pm
Contact:

Post

by Lone_Ranger » Thu 05 Feb , 2009 21:16 pm

Emimec wrote:Hi
Many thanks for the link and further information.
The RS232 configuration looks exactly the same as for the Bridgeport/Heidenhain.
A thought crossed my mind, what software is used to perfom the download/uploads?

For the Bridgeport I use the freely available TNCremont, or server program. I suppose i could try this, or even have a go on hyperterminal.

Any good, reliable DNC software will do the job, if the TNCremont will work a Bridgeport with Fanuc control then it should be OK.

I never «got on» with Hyper Terminal somehow and I have a DNC in my BobCAD-CAM software so no problem.

You can get a free one here http://www.cadem.com/ if you download their Demo software you get the DNC to keep for free for ever.

BTW I checked the software version in my OT-B Cyclone and it almost the same as yours, 2.037I.

Regards
Rob


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Thu 05 Feb , 2009 22:21 pm

Hi Rob
Once again, many thanks.

I’ll see if the Bridgeport one works, if not, I’ll go for the one you sent a link for. I’m not a fan of hyperterminal either.

Saturday is the day to try out all the advice given here, I will know much more hopefully after the tests
Regards
bob


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Sun 08 Feb , 2009 10:18 am

Hi Rob
Many thanks for taking the time to assist me over the phone Saturday.
I am now more aware of the problem, and happy with the understanding of the parameter situation.

If you get a chance to see what you have for the diagnostics lines, 530 or 450 I think, I’d be most grateful. Also, where can I download the whole lot, so if needed, can us the RS232 to upload to the machine.

I have found the item you disussed on ebay, and may well go for it !!

I have one more question. I have a small adapter, 25 pin male one end, 25 pin female the other end that came with the machine, its a Denford labelled part and says «EDITOR AUIOCAM TURNING» on that label. I thought at first it is just a connector, but do wonder now if it is something more?

Kind Regards
Bob


User avatar

Lone_Ranger

CNC Expert
CNC Expert
Posts: 220
Joined: Mon 01 Oct , 2007 15:23 pm
Contact:

Post

by Lone_Ranger » Sun 08 Feb , 2009 14:07 pm

Emimec wrote:Hi Rob
Many thanks for taking the time to assist me over the phone Saturday.
I am now more aware of the problem, and happy with the understanding of the parameter situation.

If you get a chance to see what you have for the diagnostics lines, 530 or 450 I think, I’d be most grateful. Also, where can I download the whole lot, so if needed, can us the RS232 to upload to the machine.

I have found the item you disussed on ebay, and may well go for it !!

I have one more question. I have a small adapter, 25 pin male one end, 25 pin female the other end that came with the machine, its a Denford labelled part and says «EDITOR AUIOCAM TURNING» on that label. I thought at first it is just a connector, but do wonder now if it is something more?

Kind Regards
Bob

Hi Bob

See attached file for the Diagnostics Info, it is a .txt file so will open OK in Notepad/Wordpad.
Remember these are for reference only, my machine may be set a little different to yours. (Having said that it does work!!)

Normally only the Diagnostics 0300 to 0499 are able to be uploaded/downloaded via the RS232 cable, the rest have to be done by hand, there may be a way but so far I haven`t found it yet!!

Sorry, no idea what that adapter could be for unless it was for some kind of external DNC hardware but I have never heard of needing anything special to connect to Fanuc!!! A Google search throws up stuff like «Video Capture» hardware!! If it had been only pins at one end I would have thought is was possibly a «Dongle» of some kind!!!

No doubt someone at Denford will have the info on it for you.

Hope you get it sorted OK.
Regards
Rob

:mrgreen: :mrgreen: :mrgreen: :mrgreen: :mrgreen:

.

Attachments
Diagnostics OT-B.TXT
(6.39 KiB) Downloaded 804 times


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Sun 08 Feb , 2009 14:24 pm

Many Thanks.

I emailled you earlier as to how I wind the slides manually off the limits stops. I cant see how any covers are removed, especially the X slide with the turret on.

Regards
Bob


Martin

CNC Guru
CNC Guru
Posts: 1875
Joined: Fri 24 Feb , 2006 17:09 pm
Location: Brighouse

Post

by Martin » Sun 08 Feb , 2009 19:46 pm

Hi,

There will be a «Axis Limit Switch Overide» button on the right hand side of the control panel housing. If you press & hold in the button it will overide the Axis Limit Switches & allow you to drive the axis clear using the control. I sugest you move slides to the centre & then release the button.


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Sun 08 Feb , 2009 20:06 pm

Many thanks for the reply.
It appears my machine is in e stop fault condition, and carrying out your advice will not work. I did try yesterday. I have since found out there is a manual way of moving the slides, and now know how to do it. My «Not ready» warning and fault codes on the Fanuc may well be due to a faulty power unit, not sure yet, and moving the slides was a half hearted attempt to see if it cleared them.
Bob


User avatar

Denford Admin

Site Admin
Posts: 3627
Joined: Fri 10 Feb , 2006 12:40 pm
Hardware/Software: Go to User Control Panel > Profile
Enter as much information about your CNC hardware and software as you can — it makes it easier for everyone to know what you’re talking about then.
Location: Sunny Brighouse
Contact:

Post

by Denford Admin » Mon 09 Feb , 2009 9:54 am

I have one more question. I have a small adapter, 25 pin male one end, 25 pin female the other end that came with the machine, its a Denford labelled part and says «EDITOR AUIOCAM TURNING» on that label. I thought at first it is just a connector, but do wonder now if it is something more?

I think this is a dongle for the AutoDesk/AutoCAD CAM software that was around at that time, see here: viewtopic.php?t=371


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Sun 15 Feb , 2009 12:28 pm

Small amount of progress after Saturdays poking around in the machine and power supply box.

There is no power on wire 31 in the big black floor standing box power unit. This is strange, as it is looped from another breaker which has power.

Second query is: the spindle drive motor fan seems to be running all the time. Is this correct? and what is in the black box behind the spindle drive motor? It has a cover on, and is accessible from the rear of the machine under the PCB boards, if you remove a clear plastic window.

No amount of trying will allow the input of any parameters, machine definately stuck in e stop mode.

New Fanuc power unit should arrive this week, will try this asap.


User avatar

Lone_Ranger

CNC Expert
CNC Expert
Posts: 220
Joined: Mon 01 Oct , 2007 15:23 pm
Contact:

Post

by Lone_Ranger » Sun 15 Feb , 2009 14:03 pm

Emimec wrote:Small amount of progress after Saturdays poking around in the machine and power supply box.

There is no power on wire 31 in the big black floor standing box power unit. This is strange, as it is looped from another breaker which has power.

Second query is: the spindle drive motor fan seems to be running all the time. Is this correct? and what is in the black box behind the spindle drive motor? It has a cover on, and is accessible from the rear of the machine under the PCB boards, if you remove a clear plastic window.

No amount of trying will allow the input of any parameters, machine definately stuck in e stop mode.

New Fanuc power unit should arrive this week, will try this asap.

Hi Bob

When you first switch on by pressing the Green button below the screen icon the contactor at the end of the row of breakers in the power box should engage, then the screen should start to show the Cyclone information, software build etc will «write» across the screen, next you should hear 2 distinct «thuds» with a short gap between them, these are contactors engaging in the main control box at the rear of the machine. They are done with this small delay to avoid a surge that would normally drop the main breaker out.

A check for you to do, switch off everything and press the E stop button in and then switch the power box back on, all you should have on will be the fans and lights, nothing on the screen. Check for 115V AC at the breakers (Top and bottom) there should be no reading, then press the green on button with the E stop still pressed, this is when the small contactor at the end of the row of breakers should engage and then you should have 115V AC when measured from the breaker connections to earth, if one of the breaker connections eg with cable 31 attached has no 115V and the others do then you are likely to be a phase down somewhere or the breaker itself is faulty.
You can check for output from the Fanuc power supply box in the main control panel as that (If I remember correctly!!) is where the 115V is produced and fed to the power box breakers and then back to the drives etc in the control box!!
On later Cyclones they did away with that system and everything was housed in the main box on the rear of the machine which made fault finding a lot easier!!
During the above you should have a «Not Ready» alarm flashing on your screen.

When you have checked that try releasing the E stop and that is when you should hear the other 2 contactors engage one after the other!

Hope that was clear and of some use to you.

Regards
Rob

BTW I`d make a very determined effort to find that software if you get the chance, colleges were noted way back then for spending good money on top level stuff!! A good example is the Cyclone itself, it`s really a small industrial Lathe, way above what`s needed for tuition!!

:) :) :) :) :)
.


User avatar

Lone_Ranger

CNC Expert
CNC Expert
Posts: 220
Joined: Mon 01 Oct , 2007 15:23 pm
Contact:

Post

by Lone_Ranger » Sun 15 Feb , 2009 14:27 pm

Emimec wrote:
No amount of trying will allow the input of any parameters, machine definately stuck in e stop mode.

Hi Bob

You should be able to access the Parameters even in E Stop mode, have you «Enabled» the PWE on the second screen when you go to Parameters?

You can`t alter anything on the parameters without the PWE (Parameter Write Enable) set to «1» which is on, it is normally set to «0» for off, so that inqusitive fingers can`t do any damage it can only be set with the «Protect» key in the OFF position, that key is usually removed by Supervisors etc!!

If you want to try it switch the power box on and leave the E Stop button depressed, then press the DGNOS/PARM button and then use the page down button to go to page 2 and you will see the PWE, use the cursor buttons to align the cursor with PWE and you will see at the bottom of the screen PWE = turn the protect key to the right and press 1 on the number keypad and then input and the «0» next to PWE should change to a «1», you can now alter, upload, download any/all parameters/diagnostics!!

When you have finished change the PWE back to «0» to disable the «Write» ability.

WARNING Always write down any parameter you intend to alter before you do it!!

Regards
Rob

:) :) :) :) :)

.


Emimec

CNC Expert
CNC Expert
Posts: 125
Joined: Tue 03 Feb , 2009 10:42 am
Location: North London

Post

by Emimec » Sun 15 Feb , 2009 15:28 pm

Hi Rob
Both of your post offer excellent advice. I will try all procedures.
I do not get the second, time delay thuds of breakers going in. The new box I bought is on its way from America.
Thanks
Bob


  1. Hello,
    I have a cnc tour colchester (electronic triumph)
    When I start the CN fanuc, I have this message (1008 AXIS OVERLOAD DETECTED).
    and when I try to move on the X or Z axis, it moves a very small movement of 1 mm only and I receive a new message (414 X-axis detect error), after I check the diagnostic messages number 200 I found OVC = 1 (OVERCURENT) and when I set the reset the error is gone and it returns the same problem of displacement with 1 mm

    I check the motor and the cables I found that they worked well.
    I hope to find who to help me


  2. Re: fanuc 20t 1008 AXIS OVERLOAD DETECTED

    This might be the driver (overload alarm) or the servomotor


  3. Re: fanuc 20t 1008 AXIS OVERLOAD DETECTED

    thank you very much sir for your answer, I check the hardware and I found them that it works very well but I found a loss of parameters LADDER PMC (timer counter Keep relay and data )knowing that I’ve found that all the parameters are initialized to zero so I propose that if any of you or if you know someone who has the same turn to help us by the sending of parametre for uses it to settle mine.


  4. Re: fanuc 20t 1008 AXIS OVERLOAD DETECTED

    i’m sorry we only have fanuc 18i


Similar Threads

  1. Replies: 3

    Last Post: 01-24-2016, 02:41 PM

  2. Replies: 1

    Last Post: 02-25-2013, 04:42 PM

  3. Replies: 1

    Last Post: 06-23-2011, 12:42 PM

  4. Replies: 4

    Last Post: 10-15-2010, 07:10 PM

  5. Replies: 1

    Last Post: 08-10-2007, 12:55 AM

Tags for this Thread


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

На станке при включении выдаётся ошибка 1008 FAULT of SUPPLY «Неисправность однофазного питания привода револьверной головки 220В». Через 1-1,5 часа ошибка сбрасывается. Дальше станок работает нормально. Если отключить станок более чем на 20 мин, ошибка появляется снова. Работать при такой неисправности на станке не возможно, так как можно было бы совсем станок не выключать, но тут вмешиваются требования по технике безопасности, согласно которым оператора, оставившего станок включённым требуется наказать вплоть до увольнения. Блоком управления приводом револьверной головки DUPLOMATIC DDC4-20-230/20 выдаётся ошибка как ALBIT1.

Не представляем что надо делать, если заменить блок управления приводом револьверной головки DUPLOMATIC DDC4-20-230/20 на новый. Ведь там есть какие-то прошивки (вот какие надписи на шильдике блока управления):

CODICE — 0496302      230V

SCHEDA AZION.  —  100815344     3606

SCHEDA ALIM.  —  110811036    4907

SOFTWARE DSP  —  DSP230 VER. 2.8

SCHEDA I/O  —  110811068   3906

SCHEDA FILTRO  —   110743612    2506

Надо ли что-то заливать в новый блок или эти данные надо указывать при заказе нового блока? Если надо то какими средствами и где брать прошивки?

Может у кого есть опыт и сталкивался с подобной проблемой?

Понятно, что неисправность в блоке управления, но куда лезть — не понятно. Все питания внешние 220В, 24В присутствуют и проблем по внешним сигнальным цепям и питанию нет. 

Прошу помочь:

1. Документацией на блок управления DUPLOMATIC DDC4-20-230/20.

2. Советом, если кто сталкивался с аналогичной проблемой.

Fanuc Alarms and Errors e.g. Program errors (P/S alarm), Over travel alarms, Servo alarms etc.

Fanuc Alarm BG914 V–DEVICE DRIVER ERROR (RANGE)

Fanuc Alarm BG914 V–DEVICE DRIVER ERROR (RANGE) Fanuc Alarm Description Fanuc 15i An error occurred during device driver control.

Fanuc Alarm PS1010 ILLEGAL RESTART (NURBS)

Fanuc Alarm PS1010 ILLEGAL RESTART (NURBS) Fanuc Alarm Description Fanuc 15i An attempt was made to resume NURBS interpolation after manual intervention with manual absolute ON.

Fanuc Alarm PS1070 ILLEGAL USE OF G41.5/G42.5

Fanuc Alarm PS1070 ILLEGAL USE OF G41.5/G42.5 Fanuc Alarm Description Fanuc 15i (1) The parameters related to three–dimensional cutter compensation for rotary table are not specified properly. (2) An attempt…

Fanuc Alarm PS1001 ILLEGAL ORDER (NURBS)

Fanuc Alarm PS1001 ILLEGAL ORDER (NURBS) Fanuc Alarm Description Fanuc 15i The specified number of levels is incorrect.

Fanuc Alarm PS1002 NO KNOT COMMAND (NURBS)

Fanuc Alarm PS1002 NO KNOT COMMAND (NURBS) Fanuc Alarm Description Fanuc 15i Knot has not been specified, or a block not related to NURBS interpolation was specified in the NURBS…

Fanuc Alarm PS1100 ILLEGAL PARAMETER OF MACHINE COMPONENT

Fanuc Alarm PS1100 ILLEGAL PARAMETER OF MACHINE COMPONENT Fanuc Alarm Description Fanuc 15i A machine component parameter (No. 6161 to 6195 or No. 7540 to 7548) is invalid.

Fanuc Alarm PS998 G41.3 ILLEGAL START_UP

Fanuc Alarm PS998 G41.3 ILLEGAL START_UP Fanuc Alarm Description Fanuc 15/15i (1) The G41.3 G code (startup) was specified in a group 01 mode for other than G00 and G01….

Fanuc Alarm PS999 ILLEGAL PARAMETER IN G41.3

Fanuc Alarm PS999 ILLEGAL PARAMETER IN G41.3 Fanuc Alarm Description Fanuc 15/15i The parameter settings (parameter Nos. 6080 to 6089) for determining the relationship between the axis of rotation and…

Fanuc Alarm PS1009 ILLEGAL 1ST CONTROL POINT (NURBS)

Fanuc Alarm PS1009 ILLEGAL 1ST CONTROL POINT (NURBS) Fanuc Alarm Description Fanuc 15i The No. 1 control point is erroneous, or there is no continuity with the previous block.

Fanuc Alarm PS997 ILLEGAL COMMAND IN G41.3

Fanuc Alarm PS997 ILLEGAL COMMAND IN G41.3 Fanuc Alarm Description Fanuc 15/15i (1) A G code other than G00 or G01 in group 01 was specified in the G41.3 mode….

Fanuc Alarm PS1008 ILLEGAL KNOT VALUE (NURBS)

Fanuc Alarm PS1008 ILLEGAL KNOT VALUE (NURBS) Fanuc Alarm Description Fanuc 15i Knot is not increased TANCHO.

Fanuc Alarm PS996 G41.3/G40 FORMAT ERROR

Fanuc Alarm PS996 G41.3/G40 FORMAT ERROR Fanuc Alarm Description Fanuc 15/15i (1) A move instruction was specified in a block in which the G41.3 or G40 code is specified. (2)…

Fanuc Alarm PS1005 ILLEGAL CANCEL (NURBS)

Fanuc Alarm PS1005 ILLEGAL CANCEL (NURBS) Fanuc Alarm Description Fanuc 15i The NURBS interpolation mode was turned OFF even though NURBS interpolation was not completed.

Fanuc Alarm PS1006 ILLEGAL MODE (NURBS)

Fanuc Alarm PS1006 ILLEGAL MODE (NURBS) Fanuc Alarm Description Fanuc 15i A mode that cannot be paired with the NURBS interpolation mode was specified.

Fanuc Alarm PS1007 ILLEGAL MULTI–KNOT

Fanuc Alarm PS1007 ILLEGAL MULTI–KNOT Fanuc Alarm Description Fanuc 15i Nested knots for each level can be specified for the start and end points.

Fanuc Alarm PS1004 ILLEGAL KNOT

Fanuc Alarm PS1004 ILLEGAL KNOT Fanuc Alarm Description Fanuc 15i There is an insufficient number of knot individual blocks.

Fanuc Alarm PS1003 ILLEGAL AXIS COMMAND (NURBS)

Fanuc Alarm PS1003 ILLEGAL AXIS COMMAND (NURBS) Fanuc Alarm Description Fanuc 15i An axis not specified as a control point was specified in the No. 1 block.

Fanuc Alarm PS935 ILLEGAL FORMAT IN G02.2/G03.2

Fanuc Alarm PS935 ILLEGAL FORMAT IN G02.2/G03.2 Fanuc Alarm Description Fanuc 15i The end point of an involute curve on the currently selected plane, or the center coordinate instruction I,…

Fanuc Alarm PS936 ILLEGAL COMMAND IN G02.2/G03.2

Fanuc Alarm PS936 ILLEGAL COMMAND IN G02.2/G03.2 Fanuc Alarm Description Fanuc 15i An illegal value was specified in the involute curve. The coordinate instruction I, J or K of the…

Fanuc Alarm PS937 OVER TOLERANCE OF END POINT

Fanuc Alarm PS937 OVER TOLERANCE OF END POINT Fanuc Alarm Description Fanuc 15/15i The end point is not positioned on the involute curve that passes through the start point, and…

Fanuc Alarm PS994 SPL : ERROR

Fanuc Alarm PS994 SPL : ERROR Fanuc Alarm Description Fanuc 15 In NURBS interpolation by high–precision contour control using a RISC processor, NURBS interpolation was resumed after manual intervention with…

Fanuc Alarm PS995 ILLEGAL PARAMETER IN G41.2/G42.2

Fanuc Alarm PS995 ILLEGAL PARAMETER IN G41.2/G42.2 Fanuc Alarm Description Fanuc 15i The parameter settings (parameter Nos. 6080 to 6089) for determining the relationship between the axis of rotation and…

Fanuc Alarm PS900 G72.1 NESTING ERROR

Fanuc Alarm PS900 G72.1 NESTING ERROR Fanuc Alarm Description Fanuc 10/11/12/15/15i G72.1 was specified again during G72.1 rotation copying.

Fanuc Alarm PS901 G72.2 NESTING ERROR

Fanuc Alarm PS901 G72.2 NESTING ERROR Fanuc Alarm Description Fanuc 10/11/12/15/15i G72.2 was specified again during G72.2 parallel copying.

Fanuc Alarm PS920 ILL–COMMAND IN G05.1 Q1

Fanuc Alarm PS920 ILL–COMMAND IN G05.1 Q1 Fanuc Alarm Description Fanuc 15 An invalid command was specified in G05.1 Q1 (look–ahead acceleration/deceleration before interpolation) mode. (1) F1–digit command

Fanuc Alarm PS991 SPL: ILLEGAL COMMAND

Fanuc Alarm PS991 SPL: ILLEGAL COMMAND Fanuc Alarm PS991 SPL : ERROR Fanuc Alarm Description Fanuc 15/15i A G06.1 code was specified in a G code mode in which the…

Fanuc Alarm PS992 SPL: ILLEGAL AXIS MOVING

Fanuc Alarm PS992 SPL: ILLEGAL AXIS MOVING Fanuc Alarm PS992 SPL : ERROR Fanuc Alarm Description Fanuc 15i Movement was specified for an axis other than those used for spline…

Fanuc Alarm PS990 SPL: ILLEGAL AXIS COMMAND

Fanuc Alarm PS990 SPL: ILLEGAL AXIS COMMAND Fanuc Alarm PS990 SPL : ERROR Fanuc Alarm Description Fanuc 15i An illegal axis was specified for spline interpolation or smooth interpolation. This…

Fanuc Alarm PS993 SPL: CAN’T MAKE VECTOR

Fanuc Alarm PS993 SPL: CAN’T MAKE VECTOR Fanuc Alarm PS993 SPL : ERROR Fanuc Alarm Description Fanuc 15i A 3–dimensional tool offset vector cannot be generated. · In generation of…

Fanuc Alarm PS897 ILLEGAL COMMAND IN G02.3/G03.3

Fanuc Alarm PS897 ILLEGAL COMMAND IN G02.3/G03.3 Fanuc Alarm Description Fanuc 15i An illegal value was specified in exponential interpolation. The natural logarithm parameter fell to less than “0” during…

Fanuc Alarm PS808 DEVICE DOUBLE OPENED

Fanuc Alarm PS808 DEVICE DOUBLE OPENED Fanuc Alarm Description Fanuc 15i An attempt was made to open a device that is being accessed.

Fanuc Alarm PS809 ILLEGAL COMMAND IN G41/G42

Fanuc Alarm PS809 ILLEGAL COMMAND IN G41/G42 Fanuc Alarm Description Fanuc 15i Specified direction tool length compensation parameters are incorrect. A move instruction for a axis of rotation was specified…

Fanuc Alarm PS891 ILLEGAL COMMAND G05

Fanuc Alarm PS891 ILLEGAL COMMAND G05 Fanuc Alarm Description Fanuc 10/11/12/15 G05 was specified in a state in which G05 cannot be specified.

Fanuc Alarm PS895 ILLEGAL PARAMETER IN G02.3/G03.3

Fanuc Alarm PS895 ILLEGAL PARAMETER IN G02.3/G03.3 Fanuc Alarm Description Fanuc 15i The parameter setting that specifies the axis on which to execute exponential interpolation is incorrect. Parameter No. 7636:…

Fanuc Alarm PS896 ILLEGAL FORMAT IN G02.3/G03.3

Fanuc Alarm PS896 ILLEGAL FORMAT IN G02.3/G03.3 Fanuc Alarm Description Fanuc 15i The format for specifying exponential interpolation is incorrect. Addresses I slope angle, J excessive torsion and setting R…

I tried Kroser_12 suggestion it posts indexing moves the way it should switching clamp & unclamp at right times but when I post for simultaneous moves this is what I get.

%
O1001 (FLAT .120 HOLE)
(T2 D=0.125 CR=0. — FLAT END MILL)
N10 G90 G94 G17 G49 G40 G80
N15 G20
N20 G28 G91 Z0.
N25 G90

(2D ADAPTIVE POCKETS)
N30 T2 M06
N35 S8000 M03
N40 G54
N45 M08
N55 G00 X-0.4558 Y0.
N60 G43 Z1.35 H02

Should have M26 (un clamp) here
N65 G00 A46.776
N70 Z0.95
N75 Z0.8645
N80 G01 Z0.852 F24.
N85 G93 X-0.4645 Z0.8512 A45.015 F687.33
N90 X-0.4646 Z0.8504 A43.111 F824.89
N95 X-0.456 Z0.8496 A41.345 F689.67
N100 X-0.4401 Z0.8488 A39.98 F663.13
N105 X-0.4191 Z0.848 A39.217 F744.07
N110 X-0.3963 Z0.8472 A39.169 F1018.41
N115 X-0.3749 Z0.8464 A39.843 F765.49
N120 X-0.3582 Z0.8456 A41.14 F668.41

N120330 A-559.735 F1920.02
N120335 Z0.5629 A-559.406 F6550.97
N120340 Z0.5642 A-559.099 F5617.33
N120345 Z0.5662 A-558.835 F5226.3
N120350 Z0.5687 A-558.633 F5220.36
N120355 Z0.5718 A-558.505 F5602.11
N120360 Z0.575 A-558.462 F6538.39

 Should have M25 (clamp) here
N120365 G00 Z1.35
N120375 G94

N120380 M09
N120385 G28 G91 Z0.
N120390 G49
N120395 M26            These next 3 lines work the way they should.
N120400 G00 A0.    
N120405 M25
N120410 G28 X0. Y0.
N120415 M30
%

Anybody else have this same problem?