Ошибка 0xc02020f4 sql

Using the Import/Export Wizard, I ended up with an annoying problem:

Error 0xc02020f4: Data Flow Task 1: The column «pinNumber» cannot be processed because more than one code page (874 and 1252) are specified for it.

Looks like a different codepage (SQL_Latin1_General_CI_AS vs Latin1_General_CI_AS), so I changed those to match: Latin1_General_CI_AS for both.

However, the wizard still throws an error and detects two codepages — I even checked the tables and both source and destination show the same Latin1_General_CI_AS collation.

RolandoMySQLDBA's user avatar

asked Aug 5, 2012 at 2:13

Agony's user avatar

8

Problem can be in field level as it was for me.

In a source database, a field in a table had a different collation in a varchar datatype.

If you choose < database default> for collation property of the fields, the problem may be solved.

RolandoMySQLDBA's user avatar

answered May 27, 2013 at 6:25

masoud Cheragee's user avatar

RRS feed

  • Remove From My Forums
  • Question

  • Hi, I’m trying to import a csv file into SQL Server MS 2016, and I get the following message:

    Error 0xc02020f4: Data Flow Task 1: The column «Claim Line ID» cannot be processed because more than one code page (65001 and 1252) are specified for it. (SQL Server Import and Export Wizard)

    This is field properties:  [Claim Line ID] [varchar](50) NULL

    The field is never longer than 10.

    Is there a way to fix this? Thanks!

All replies

  • can you script out your table and post it here?

  • Too many fields to show all, but the first one that errors out is shown:

    CREATE

    TABLE[dbo].[Table](


    [Claim Line ID] [varchar]

    (50)NULL,


    [NPI #] [bigint]

    NULL,


    [Fed Tax ID] [varchar]

    (50)NULL,


    [Tax ID Name] [varchar]

    (250)NULL,


    [Acct #] [varchar]

    (50)NULL,


    [Date of Service Start] [datetime]

    NULL,


    [Date of Service Finish] [datetime]

    NULL,


    [Service Location Name] [varchar]

    (250)NULL,


    [SLN Address] [varchar]

    (250)NULL,

    .

    .

    .

    [Trace #] [varchar]

    (250)NULL

    )

    ON[PRIMARY]

  • because more than one code page (65001 and 1252)

    That means you try to import UTF-8 (= code page 65001) into a ASCII field (= varchar with CP
    1252) without any conversion, which causes loosing data. You must convert the data before.


    Olaf Helper

    [ Blog] [ Xing] [ MVP]

  • It probably means that csv comma delimited is not supported by SQL Server? Thanks.

  • Hi bekis,

    what is collation of database ?

    SELECT DATABASEPROPERTYEX(‘dbname’‘Collation’)

    if you set collation default,will reslove problem.

    http://dba.stackexchange.com/questions/22010/import-export-wizard-code-page-error


    Please Mark it as Answered if it answered your question OR mark it as Helpful if it help you to solve your problem.

  • It probably means that csv comma delimited is not supported by SQL Server? Thanks.

    No, the Import/Export Wizard supports CSV source file very well, but SQL Server don’t support UTF-8 character set, «only» ASCII and Unicode. You have to convert the UTF-8 file to Unicode or ASCII.


    Olaf Helper

    [ Blog] [ Xing] [ MVP]

  • It probably means that csv comma delimited is not supported by SQL Server? Thanks.

    BULK
    INSERT 
    Table
    FROM ‘c:\csvtest.txt’
    WITH
    (
    FIELDTERMINATOR ‘,’,
    ROWTERMINATOR ‘\n’
    )
    GO
    —Check the content of the table.
    SELECT *
    FROM Table

    Refer following table.

    http://blog.sqlauthority.com/2008/02/06/sql-server-import-csv-file-into-sql-server-using-bulk-insert-load-comma-delimited-file-into-sql-server/ 


    Please Mark it as Answered if it answered your question OR mark it as Helpful if it help you to solve your problem.

    • Edited by

      Wednesday, November 23, 2016 7:02 AM

  • Hi, the database collation is SQL_Latin1_General_CP1_CI_AS. The Collation dropdown does not have ‘Default’ option. How do I change it? Thanks!

  • check server collation

    SELECT CONVERT (varchar, SERVERPROPERTY('collation'));  
    

    SELECT CONVERT (varchar, SERVERPROPERTY(‘collation’));


    Please Mark it as Answered if it answered your question OR mark it as Helpful if it help you to solve your problem.

  • CSV is very much supported by SQL Server.

    Can I ask you to do this, script out your table again, but this time include collation. use the Tasks options to script the table out. Otherwise we miss the collation.

  • Server collation:  SQL_Latin1_General_CP1_CI_AS

  • The table collation is: SQL_Latin1_General_CP1_CI_AS

  • Thank you, I have requested a text-tab delimited file type.

  • I received a tab delimited text file, however, when uploading with ‘1252 ANSI Latin’ option selected, I get this error:

    Error 0xc02020a1: Data Flow Task 1: Data conversion failed. The data conversion for column «Tax ID Name» returned status value 4 and status text «Text was truncated or one or more characters had no match in the target code page.».
     (SQL Server Import and Export Wizard)

    Does this mean that the text file has some codes (such as UTF-8) that are not supported by SQL Server?

    Thanks!

  • Hi All,

    I received this error when attempting to import a .CSV file. After some investigation I discovered that it was because I had saved the file as «CSVUTF-8 (Comma Delimited) (*.CSV)» from Excel. When I resaved the same file but as «CSV (Comma
    Delimited) (*.CSV)» instead the import worked fine.

    It may also be worth noting that I used the «Import Data» option and set the destination as «Microsoft OLE DB Provider for SQL Server».

    Hope this helps you all.

I try to load a big CSV file (10M lines, 100 columns!) into a SQL Server 2014 DB .

In input, I have:

  • a CSV file, generated by an external company with these parameters
    (impossible to make it use other settings)

· code page ISO-8859-15 (Latin 9)

· field delimiter: ;

· text delimiter: «

· DOS/Windows end of lines (CRLF)

  • SQL «CREATE TABLE» command with right types and lengths for each column

When I try to populate this table with import wizard, I’ve many 0xc02020f4 errors:
«The column «xxx» cannot be processed because more than one code page (28605 and 1252) are specified for it. (SQL Server Import and Export Wizard)»

How can I deal with this problem ?

Should I create a DB or table with special collation ?

The table has 100 columns, I’d like to get a solution at higher level than column… ;o)

Thanks by advance.
Regards,
Steph.

asked Oct 18, 2017 at 14:39

Steph_P92's user avatar

2

In the Import Export Wizard make sure you change the Code Page to 1252 (ANSI — Latin 1) instead of ISO-8859-15 (Latin 9).

answered Feb 27, 2019 at 14:44

Lawrence's user avatar

Using the Import/Export Wizard, I ended up with an annoying problem:

Error 0xc02020f4: Data Flow Task 1: The column «pinNumber» cannot be processed because more than one code page (874 and 1252) are specified for it.

Looks like a different codepage (SQL_Latin1_General_CI_AS vs Latin1_General_CI_AS), so I changed those to match: Latin1_General_CI_AS for both.

However, the wizard still throws an error and detects two codepages — I even checked the tables and both source and destination show the same Latin1_General_CI_AS collation.

RolandoMySQLDBA's user avatar

asked Aug 5, 2012 at 2:13

Agony's user avatar

8

Problem can be in field level as it was for me.

In a source database, a field in a table had a different collation in a varchar datatype.

If you choose < database default> for collation property of the fields, the problem may be solved.

RolandoMySQLDBA's user avatar

answered May 27, 2013 at 6:25

masoud Cheragee's user avatar

I’m trying to copy data from one database to another with built-in export tool.
but I get this error:

Error 0xc02020f4: Data Flow Task 1: The column "Name" cannot be processed because more than one code page (1250 and 1252) are specified for it.
 (SQL Server Import and Export Wizard)



Error 0xc02020f4: Data Flow Task 1: The column "CatalogNo" cannot be processed because more than one code page (1250 and 1252) are specified for it.
 (SQL Server Import and Export Wizard)

Error 0xc004706b: Data Flow Task 1: "Destination - Device" failed validation and returned validation status "VS_ISBROKEN".
 (SQL Server Import and Export Wizard)

Error 0xc004700c: Data Flow Task 1: One or more component failed validation.
 (SQL Server Import and Export Wizard)

Error 0xc0024107: Data Flow Task 1: There were errors during task validation.
(SQL Server Import and Export Wizard)

I know that error:

Error 0xc004706b: Data Flow Task 1: "Destination - Device" failed validation and returned validation status "VS_ISBROKEN".
 (SQL Server Import and Export Wizard)

Is probably caused by wrong order of copying data. ( FK)

And the first two errors are caused by not the same collation in the columns.

Databases and tables have same collation. How can I set columns to use table default collation?
I tried to change this manually but in collation list on the column lvl there is no collation set for table and db.

Palak.Maheria's user avatar

asked Apr 3, 2014 at 8:22

szpic's user avatar

Ok. I change It manually in Design ->Collation->Restore default
after that I copied all the data.

answered Apr 3, 2014 at 8:44

szpic's user avatar

szpicszpic

4,35615 gold badges54 silver badges86 bronze badges