I’m trying to import a text file of 200k rows into sql server using sql server management studio 17. but its showing the following error:
Error 0xc0202009: Data Flow Task 1: SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005.
An OLE DB record is available. Source: "Microsoft OLE DB Provider for SQL Server" Hresult: 0x80004005 Description: "Invalid character value for cast specification.".
(SQL Server Import and Export Wizard)
Error 0xc020901c: Data Flow Task 1: There was an error with Destination - DimStudent.Inputs[Destination Input].Columns[DateOfBirth] on Destination - DimStudent.Inputs[Destination Input]. The column status returned was: "Conversion failed because the data value overflowed the specified type.".
(SQL Server Import and Export Wizard)
Error 0xc0209029: Data Flow Task 1: SSIS Error Code DTS_E_INDUCEDTRANSFORMFAILUREONERROR. The "Destination - DimStudent.Inputs[Destination Input]" failed because error code 0xC020907A occurred, and the error row disposition on "Destination - DimStudent.Inputs[Destination Input]" specifies failure on error. An error occurred on the specified object of the specified component. There may be error messages posted before this with more information about the failure.
(SQL Server Import and Export Wizard)
Error 0xc0047022: Data Flow Task 1: SSIS Error Code DTS_E_PROCESSINPUTFAILED. The ProcessInput method on component "Destination - DimStudent" (158) failed with error code 0xC0209029 while processing input "Destination Input" (171). The identified component returned an error from the ProcessInput method. The error is specific to the component, but the error is fatal and will cause the Data Flow task to stop running. There may be error messages posted before this with more information about the failure.
(SQL Server Import and Export Wizard)
Error 0xc02020c4: Data Flow Task 1: The attempt to add a row to the Data Flow task buffer failed with error code 0xC0047020.
(SQL Server Import and Export Wizard)
Error 0xc0047038: Data Flow Task 1: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED. The PrimeOutput method on Source - DimStudent_txt returned error code 0xC02020C4. The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing. There may be error messages posted before this with more information about the failure.
(SQL Server Import and Export Wizard)
I’m new to this. it would be great if someone could tell how to resolve this issue.
James Z
12.2k10 gold badges24 silver badges44 bronze badges
asked May 30, 2017 at 5:34
The error message states:
"Conversion failed because the data value overflowed the specified type.".
One of the rows has a value that does not fit into the destination table for some reason. You didn’t specify the datatypes, but I am guessing the output column might not be a proper date/time column.
However, without knowing the table setup and/or seeing some of the data, we can only guess.
answered May 30, 2017 at 6:13
SchmitzITSchmitzIT
9,2659 gold badges65 silver badges92 bronze badges
Ran into same error, I had columns that were set not to allow null by the auto import. Set them to allow nulls and everything completed.
answered Nov 16, 2022 at 21:44
Search code, repositories, users, issues, pull requests…
Provide feedback
Saved searches
Use saved searches to filter your results more quickly
Sign up
- Remove From My Forums
-
Question
-
I’ve seen the previous threads on this (although maybe not all of them). However, i don’t think I’m getting the error for the same reason. The full error I’m getting is:
— Pre-execute (Error)
Messages
Error 0xc0202009: {F1B3B35C-FAE3-48F6-A169-4E4D8D99F9B6}: An OLE DB error has occurred. Error code: 0x80004005.
An OLE DB record is available. Source: «Microsoft JET Database Engine» Hresult: 0x80004005 Description: «Unspecified error».
(SQL Server Import and Export Wizard)Error 0xc020801c: Data Flow Task: The AcquireConnection method call to the connection manager «DestinationConnectionExcel» failed with error code 0xC0202009.
(SQL Server Import and Export Wizard)Error 0xc004701a: Data Flow Task: component «Destination 64 — production_effectivities» (7042) failed the pre-execute phase and returned error code 0xC020801C.
(SQL Server Import and Export Wizard)The entire package is running on one machine. The data source is SQL Server 2005 and the destination (this happens with both of them) is Excel or Access. Either way I cannot get the package which the wizard generated to run at all. This error occurs after the first table is exported. I’m running on WinXP SP2 with 2005 Developer and ALL components installed except analysis services.
Anyone else have this problem or know the solution?
Jeff
Answers
-
Paulino PP:The command should look like this:
«C:\Program Files (x86)\Microsoft SQL Server\90\DTS\Binn\DTExec.exe» /FILE «C:\Documents and Settings\Keith\My Documents\Visual Studio 2005\Projects\Test SSIS\Test SSIS\bin\test_ssis.dtsx» /MAXCONCURRENT » -1 » /CHECKPOINTING OFF /REPORTING EWCDI
This works if the package source is «File system». If you right click on the dtsx file and select open it should open with the Execute Package Utility, click on the last item on the left «Command Line» and you will see the full command line paramters.
If you have saved your SSIS package to the server try saving it to a file system location and following this procedure.
Make sure that Run64BitRuntime is set to False before you build and save the package.
I have an SSIS package which reads an Excel File (Data Flow Source) and transfer the data to SQL Server using OLEDB Destination Data Flow Item. The OLEDB Connection Manager used for the destination is configured to use Windows Authentication. The package works fine on my development machine. But when I open the same package on another machine and try to execute it gives the following error in Validation phase
Error: 0xC020801C at DFT_NSOffers, Source — ‘Subscription Offers$’ 1 [347]: The AcquireConnection method call to the connection manager «ExcelConnection_NSOffers» failed with error code 0xC0202009.
Error: 0xC0047017 at DFT_NSOffers, DTS.Pipeline: component «Source — ‘Subscription Offers$’ 1» (347) failed validation and returned error code 0xC020801C.
Error: 0xC004700C at DFT_NSOffers, DTS.Pipeline: One or more component failed validation.
Error: 0xC0024107 at DFT_NSOffers: There were errors during task validation
I’m using SQL Server 2005 (Version — 9.0.1399)
How do I fix this? Do I need to install any other component or service pack?
abatishchev
98.4k88 gold badges297 silver badges433 bronze badges
asked Apr 14, 2009 at 15:27
I don’t think it’s 64/32 bit error. My Dev machine and DB server are 32bit. But I could make it work. I had to set Delay Validation
property of Data Flow
tasks to TRUE
.
dns_nx
3,6514 gold badges37 silver badges66 bronze badges
answered Apr 17, 2009 at 10:32
user82613user82613
1,3232 gold badges12 silver badges17 bronze badges
3
Hi This can be solved by changing the prorperty of the project in the solution explorer then give false
to 64bit runtime
option
dns_nx
3,6514 gold badges37 silver badges66 bronze badges
answered May 2, 2014 at 12:25
I was finally able to resolve the «Excel connection issue» in my case it was not a 64 bit issue like some of them had encounterd, I noticed the package worked fine when i didnt enable the package configuration, but i wanted my package to run with the configuration file, digging further into it i noticed i had selected all the properties that were available, I unchecked all and checked only the ones that I needed to store in the package configuration file. and ta dha it works
answered Oct 25, 2010 at 15:56
VinayVinay
311 bronze badge
For me, I was accessing my XLS
file from a network share. Moving the file for my connection manager to a local folder fixed the issue.
answered Aug 13, 2013 at 8:48
If you are receiving preview of data in the excel source. But while executing the data flow task you receive Acquire connection error. Then move the file to local system and change the file path in excel connection manager and try executing again.
answered May 6, 2019 at 21:42
In my case the problem was the 32/64 bit driver which I solved by configuring the properties of the sql server job:
answered Mar 7, 2015 at 12:11
Stefan MichevStefan Michev
4,8153 gold badges35 silver badges30 bronze badges
1
I had similar issue just that excel was the destination in my case instead of source as in the case of the original question/issue. I have spent hours to resolve this issue but looks like finally Soniya Parmar saved the day for me. I have set job and let it run for few iterations already and all is good now. As per her suggestion I set up the delay validation of the Excel connection manager to ‘True. Thanks Soniya
answered Jul 5, 2014 at 7:55
Setting RetainSameConnection property to True for Excel manager Worked for me .
answered Feb 27, 2017 at 11:13
Sean PearceSean Pearce
1,1505 silver badges10 bronze badges
I had similar issue, trying to load data from Excel spreadsheet; and was running on WinX64. So I went VS BI`s project properties: Configuration Properties \ Dbugging
and Switch Run64BitRuntime from True to False.
It worked.
answered Mar 20, 2017 at 20:04
In my case password i set in expression was wrong causing this error. After assigning correct password to expression of connection manager issue resolved.
answered Aug 30, 2022 at 17:44
Muhammad YaseenMuhammad Yaseen
6611 gold badge5 silver badges6 bronze badges
In my case, none of the previous solutions here worked. Apparently Visual Studio, upon creating the Excel Source component, opens the Excel file and does not release it. Trying to then execute the SSIS package within Visual Studio leads to a AcquireConnection error with code 0xC0202009. Closing Visual Studio completely (not just the solution), reopen the solution and then run the package again without any further changes works. I found out when I tried to replace the Excel file and Windows Explorer said it couldn’t because the file was open.
answered Dec 19, 2022 at 8:55
In order to resolve this issue make all your data flow tasks in one sequence. It means it should not execute parallel. One data flow task sequence should contain only one data flow task and for this another data flow task as sequence.
Ex:-
answered Oct 14, 2014 at 11:03
Problem
SQL Server Integration Services (SSIS) is used with Informix databases and Informix CSDK for things such as data extraction and data loading. After initial installation of oledb on a Windows environment, the oledb layer works with SSIS to pass data between SQLServer and the Informix database. During the initial setup, configuration issues may prevent connectivity.
Symptom
When the user tries an Informix connection using the OLEDB data source, an error similar to the following may be encountered:
[OLE DB Source [1]] Error: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager «database@servername» failed with error code 0xC0202009.
Cause
There is a 32 bit driver and a 64 bit driver with the same name for SSIS connection managers. If both providers are visible in the environment, the correct provider will be used. If the correct provider is not visible, you may get error code 0xC0202009 at connection time.
Diagnosing The Problem
In the properties of the SSIS project, locate the ‘Run64BitRuntime’ parameter.
Run64BitRunTime=False => will find and use the 32 bit provider.
Run64BitRunTime=True => will find and use the 64 bit provider.
Resolving The Problem
If you encounter the error code 0xC0202009 with SSIS and the Informix oledbc driver, you may be able to resolve the connection problem by setting the Run64BitRunTime to the opposite value (True=>False or False => True) before you try to connect.
[{«Product»:{«code»:»SSVT2J»,»label»:»Informix Tools»},»Business Unit»:{«code»:»BU059″,»label»:»IBM Software w\/o TPS»},»Component»:»Informix Client Software Development Kit (CSDK)»,»Platform»:[{«code»:»PF033″,»label»:»Windows»}],»Version»:»3.5;3.7″,»Edition»:»»,»Line of Business»:{«code»:»LOB10″,»label»:»Data and AI»}}]