Ошибка 0x80004005 sql server compact

  • Remove From My Forums
  • Question

  • Hello, Can someone help me finding the latest version of SQL Server Compact ? My problem is the following: I created a web site actually on line that worked fine for a few years and since some time it is giving the following error when accessing
    the data base :  Unable to load the native components of SQL Compact corresponding to the ADO.NET provider version 8876. Install the correst vesion of SQLServer Compact Refer to KB article 974247 for more détails. The version of SQL Server Compact I have
    is 4.0.8854.1, I assume that I would need the version 4.0.8876.1 to solve the issue but I cannot find it. When testing my site with VS2017 it works fine, I assume that the version of ADO.NET used on the public server is different from the one in VS2017 ? Thanks
    for your help.

  • Remove From My Forums
  • Question

  • Hello, Can someone help me finding the latest version of SQL Server Compact ? My problem is the following: I created a web site actually on line that worked fine for a few years and since some time it is giving the following error when accessing
    the data base :  Unable to load the native components of SQL Compact corresponding to the ADO.NET provider version 8876. Install the correst vesion of SQLServer Compact Refer to KB article 974247 for more détails. The version of SQL Server Compact I have
    is 4.0.8854.1, I assume that I would need the version 4.0.8876.1 to solve the issue but I cannot find it. When testing my site with VS2017 it works fine, I assume that the version of ADO.NET used on the public server is different from the one in VS2017 ? Thanks
    for your help.

  • Deploy Web Site Error:Could not load file or assembly ‘System.Data.SqlServerCe, Version=4.0.0.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91’ or one of its dependencies

    I have created a ASP.NET web Site (not Web application), using Visual Studio 2012 Ultimate and «SQL Server Compact 4.0 Local Database» in my C# Code.
    I am able to successfully compile & publish the website to another IIS Web Server, with Operating System Windows Server 2008 R2 Standard. I can even test, successfully, this website on the machine I developed it in.
    I am publishing the website, from within Visual Studio, to a Network web server running IIS.  To Publish I am using Build-> «Publish Web Site».  In the Publish Profile, I am using Web Deploy Method. Even though I am using, successfully,
    «SQL Server Compact 4.0 Local Database» in my website, the «settings» (in Publish Profile) does not detect any Databases in the project. Which may not be a problem.
    When I try to bring up the web site on the IIS Web Server machine I get the following error..    
    Could not load file or assembly ‘System.Data.SqlServerCe, Version=4.0.0.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91’ or one of its dependencies .
    As my project is a Web Site, not Web Site Application, I do not have a references node in the Solution Explorer. I think the System.Data.SqlServerCe.dll, which is type GAC in my project, is not getting published to the webserver, which is causing this Error.
    Can I copy this .dll over manually ? If yes, where to put on the ISS Web Server ? I do not see any bin folder.
    Any help to resolve this error will be appreciated.
    diana4

    Hello.. I went ahead and created web application project and have gone past that error. But I have a new error now
    System.Data.SqlServerCe.SqlCeException: Unable to load the native components of
    SQL Server Compact corresponding to the ADO.NET provider of version 8876.
    Install the correct version of SQL Server Compact. Refer to KB article 974247
    for more details.
    Compiling and Publishing (Deployment) are both successful 
    In my project, when adding reference to SQL Server Compact Edition , there are 2 possible locations to reference the DDL from:
    C:\Program Files\Microsoft SQL Server Compact Edition\v4.0\Private
    C:\Program Files\Microsoft SQL Server Compact Edition\v4.0\Desktop.
    I have tried both. I get the same error as shown above.
    Interestingly, in My WebConfig, I do not see any reference to System.Data.SqlServerCe.
    Yet, the Website works when I click on Ctrl+F5 
    diana4

  • How to use Db Provider Factories with System.Data.SqlServerCe

    I’m using SQL Server Compact Edition, but in the future I would like to be able to switch to another SQL Server Edition or even a different database. To achieve this, Microsoft recommends using DB Provider Factories (see: Writing Provider Independent Code in ADO.NET, http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=674426&SiteID=1).
    I enumerated the available data providers on my PC with:
    Code Snippet
    System.Reflection.Assembly[] myAssemblies = System.Threading.Thread.GetDomain().GetAssemblies();
    The important entry is:
    «SQL Server CE Data Provider»
    «.NET Framework Data Provider for Microsoft SQL Server 2005 Mobile Edition»
    «Microsoft.SqlServerCe.Client»
    «Microsoft.SqlServerCe.Client.SqlCeClientFactory, Microsoft.SqlServerCe.Client, Version=9.0.242.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91»
    When executing:
    Code SnippetdataFactory = DbProviderFactories.GetFactory(«System.Data.SqlServerCe»);
    I got at first this error run time message:
    Failed to find or load the registered .Net Framework Data Provider.
    I added a reference to «Microsoft.SqlServerCe.Client» at C:\Programme\Microsoft Visual Studio 8\Common7\IDE\Microsoft.SqlServerCe.Client.dll and the program runs.
    Of course, it uses «Microsoft.SqlServerCe.Client» instead of «System.Data.SqlServerCe». Laxmi Narsimha Rao ORUGANTI from Microsoft writes in the post  «SSev and Enterprise Library» that «Microsoft.SqlServerCe.Client» is not meant to be used and that we should add the following entry to the machine.config file:
    Code Snippet<add name=»SQL Server Everywhere Edition Data Provider» invariant=»System.Data.SqlServerCe» description=».NET Framework Data Provider for Microsoft SQL Server Everywhere Edition» type=»System.Data.SqlServerCe.SqlCeProviderFactory, System.Data.SqlServerCe, Version=9.0.242.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91″ />
    After changing the code to:
    Code Snippet
    dataFactory = DbProviderFactories.GetFactory(«Microsoft.SqlServerCe.Client»);
    I get the same error message as before, even after adding a reference to «System.Data.SqlServerCe»  at C:\Programme\Microsoft Visual Studio 8\Common7\IDE\System.Data.SqlServerCe.dll.
    Any suggestion what I should do ? Just use «Microsoft.SqlServerCe.Client» ? Anyway, I don’t like the idea that I have to change the machine.config file, since I want to use click once deployment.

    It seems there is no DbProviderFactory for System.Data.SqlServerCe. At least I couldn’t find one, no matter how hard I searched on the Internet. I only found Microsoft.SqlServerCe.Client.SqlCeClientFactory. But we are not supposed to use Microsoft.SqlServerCe.Client and the 2 classes do have quiet some differences among their members. So I decided to write my own factory:
    Code Snippet
    public class SqlCeClientFactory: DbProviderFactory {
    public static readonly SqlCeClientFactory Instance = new SqlCeClientFactory();
    public override DbCommand CreateCommand() {
    return new SqlCeCommand();
    public override DbCommandBuilder CreateCommandBuilder() {
    return new SqlCeCommandBuilder();
    public override DbConnection CreateConnection() {
    return new SqlCeConnection();
    public override DbDataAdapter CreateDataAdapter() {
    return new SqlCeDataAdapter();
    public override DbParameter CreateParameter() {
    return new SqlCeParameter();
    That was easy enough, right ? I spent 1 week investigating the problem, 10 minutes solving it. I wonder why Microsoft didn’t include this class, because they have already the code in Microsoft.SqlServerCe.Client. I guess they have their reasons, but of course, they don’t tell us. After wasting one more month, I probably can tell. Oh, how I hate this.
    Or has anyone an idea what might be the problem ?

  • Could not load file or assembly ‘System.Data.SqlServerCe, Version=3.5.0.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91’ or one of its dependencies.

    I have updraded my pocket pc application from VS 2005 to VS 2008 and had to convert all the sqlce* files to 35 from 30. all upgraded System.Data.SqlServerCe.dll to version 3.5.0.0 and runtime version as v2.0.50727. My Target Framwork is .NET Framework 2.0.
    All the other sqlce* files are:
    sqlceca35.dll
    sqlcecompact35.dll
    sqlceer35EN.dll
    sqlceme35.dll
    sqlceoledb35.dll
    sqlceqp35.dll
    sqlcese35.dll
    The application is compiling without errors with the above dll’s and creating its own webservice dll. the webservice dll is the copied to webserver which has the following dll’s:
    sqlceca30.dll
    sqlcecompact30.dll
    sqlceer30EN.dll
    sqlceme30.dll
    sqlceoledb30.dll
    sqlceqp30.dll
    sqlcese30.dll
    and System.Data.SqlServerCe.dll as Assembly version 9.0.242.0 and file version as 3.0.5300.0.
    but when i try to run my application using the emulator, i get the following error:
     Could not load file or assembly ‘System.Data.SqlServerCe, Version=3.5.0.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91’ or one of its dependencies. The located assembly’s manifest definition does not match the assembly reference. (Exception from
    HRESULT: 0x80131040)
    i cannot upgrade the dlls on the webserver as other apps are using the 30 dlls and if i try to use 30 dlls in my application, my application fails to build  on  System.Data.SqlServerCe.dll with Assembly version 9.0.242.0 and file
    version as 3.0.5300.0.
    i have spent a few days now trying to resolve this issue and none of the solutions provided on web have helped me so far. the application does not have app.config, but adding the following code to web.config did not help either:
    <
    runtime>
    <
    assemblyBinding
    xmlns=»urn:schemas-microsoft-com:asm.v1″>
    <
    dependentAssembly>
    <
    assemblyIdentity
    name=»System.Data.SqlServerCe»
    publicKeyToken=»89845DCD8080CC91″
    culture=»neutral»/>
    <
    bindingRedirect
    oldVersion=»0.0.0.0-9.0.242.0″
    newVersion=»3.5.0.0″/>
    </
    dependentAssembly>
    </
    assemblyBinding>
    </
    runtime>
    any help will be highly appreciated.

    The binary ‘System.Data.SqlServerCe, Version=3.5.0.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91’  is only to be used for windows desktop projects. For devices the PublicKeyToken is different and you should use the device
    binary «System.Data.SqlServerCe, Version=3.5.0.0, Culture=neutral, PublicKeyToken=3be235df1c8d2ad3» to compile your device project.
    Also in addition to what Erik mentioned, please check if you have
    Microsoft SQL Server Compact 3.5 for Windows Mobile installed on your machine.
    -Tarun Ramsinghani
    Please mark this post as answers if it solves your problem.

  • HT1199 I have an Apple MacBook Pro 1,1 Mac OS X 10.6.8. I have tried to load Native Instruments Guitar Rig 4LE. It would not load and said the following. System extension cannot be used.

    I have an Apple MacBook Pro 1,1 Mac OS X 10.6.8. I have tried to load Native Instruments Guitar Rig 4LE.
    It would not load and said the following. System extension cannot be used.
    The system extension «/system/library/Extensions/AppleUSBthernetHost.text» was installed improperly and cannot be used.
    Please try reinstalling it, or contact the product vendor for an update.
    I do not have a copy of the OS X 10.6.8 software. It is second hand so I have no product vendor to contact.
    What can I do?

    You recently updated iTunes to v.11.4? This message has popped up on many a Mac screen when this version was first made available, because this kext was obviously faulty.
    You should try to download iTunes 11.4 again from Apple’s website: the new version bears the same name, but this kernel extension has been updated, and the issues it was causing are now a thing of the past.
    Should solve your problem, too…

  • Apple, please fix this bug.  Sending scanned images to «Pictures» is not what I want nor what I was able to do in every previous operation system.   I want to save all scanned items in a specific folder — NOT «PICTURES»  Please fix this bug NOW!

    Apple, please fix this bug.  Sending scanned images to «Pictures» is not what I want nor what I was able to do in every previous operation system.   I want to save all scanned items in a specific folder — NOT «PICTURES»  Please fix this bug NOW!

    I only use Image Capture, so I can’t speak for other software.
    Here is how I select a Scan To destination:
    If you are using the minimal details screen, you should have the same submenu to the left of the page size.

  • VS Exp 2013: Unable to create the Web site … The components for communicating with FTP servers are not installed.

    I have MS Visual Studio Express 2013 It has worked fine for many months and then suddenly (I have made no configuration changes or added new programs) when I try to publish I am getting the message:
    Unable to create the Web site ‘ftp://ftp.xx.xx/xxx.org.uk/www/htdocs’. The components for communicating with FTP servers are not installed.
    (I have replaced actual name with x’s).
    I had a similar problem some months ago and found that saving all files, closing VS 2013 and re-starting the program fixed the problem. This time it has not.
    I am at a loss to know how to take this forwards. I do not use IIS.
    Any help would be appreciated.
    Michael.

    Hi Michael,
    For web site development, so you use the VS2013 express for web, am I right? We have to make sure that it is not the VS version issue.
    As you said that it worked well before, did you install other add-ins or tools in your VS IDE like
    Xamarin or others?
    Maybe you could disable or remove all add-ins in your VS IDE, test it again.
    please also install the VS2013 update 4 in your side.
    Best Regards,
    Jack
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • The type initializer for ‘System.Data.SqlClient.SqlConnection’ threw an exception. InnerException: Requested registry access is not allowed.

    I have read some of the other posts for people that got this error, but none seem to apply to me.
    My program has been working for weeks.  I made some minor changes, and started getting the error (full details below).
    I did a TFS «undo pending changes» and still getting the same error, even after logging off.  The one odd thing is that I did change my Windows password this week. The connection string is using a SQL user id and password that has no issues.
    I’m an Admin own my own box (running WIn XP SP3).  I even tried «Run as Admin» on Visual Studio.
    I’m doing a Debug-Start, running a Console-Test-Program that calls a WCF service, which on local machine is hosted by «ASP.NET Development Server».
    We have two other developers, one has the same problem, one does not.  In theory, we have all done «get latest» and are running the same code.
    The SQL Connection is related to a trace database; we are using this library http://ukadcdiagnostics.codeplex.com which has worked fine for months.
    When I do «Start Run» in Visual Studio, I get this error:
    {«The type initializer for ‘System.Data.SqlClient.SqlConnection’ threw an exception. «}
    with InnerException: {«The type initializer for ‘System.Data.SqlClient.SqlConnectionFactory’ threw an exception.»}
    and it has InnerException: {«Requested registry access is not allowed. «}
    Outmost StackTrace:
       at System.Data.SqlClient.SqlConnection..ctor()
       at System.Data.SqlClient.SqlConnection..ctor(String connectionString)
       at FRB.Diagnostics.Listeners.SqlDataAccessCommand..ctor(String connectionString, String commandText, CommandType commandType)
       at FRB.Diagnostics.Listeners.SqlDataAccessAdapter.CreateCommand()
       at FRB.Diagnostics.Listeners.SqlTraceListener.TraceEventCore(TraceEventCache eventCache, String source, TraceEventType eventType, Int32 id, String message)
       at FRB.Diagnostics.Listeners.CustomTraceListener.FilterTraceEventCore(TraceEventCache eventCache, String source, TraceEventType eventType, Int32 id, String message)
       at FRB.Diagnostics.Listeners.CustomTraceListener.TraceEvent(TraceEventCache eventCache, String source, TraceEventType eventType, Int32 id, String format, Object[] args)
       at System.Diagnostics.TraceSource.TraceEvent(TraceEventType eventType, Int32 id, String format, Object[] args)
       at System.Diagnostics.TraceSource.TraceInformation(String message)
       at FRB.EC.AdminService.AdminService.TestHelloWorldWithTrace(String name)
       at SyncInvokeTestHelloWorldWithTrace(Object , Object[] , Object[] )
       at System.ServiceModel.Dispatcher.SyncMethodInvoker.Invoke(Object instance, Object[] inputs, Object[]& outputs)
       at System.ServiceModel.Dispatcher.DispatchOperationRuntime.InvokeBegin(MessageRpc& rpc)
    Second Inner StackTrace:
       at System.Data.SqlClient.SqlConnection..cctor()
    Third Inner StackTrace:
          at System.Data.SqlClient.SqlConnectionFactory..cctor()
    When I do «Run as Admin», I get this error:
    {«Could not load file or assembly ‘FRB.EFDataAccess, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null’ or one of its dependencies. Access is denied. «}
    Server stack trace:
       at System.ServiceModel.Channels.ServiceChannel.ThrowIfFaultUnderstood(Message reply, MessageFault fault, String action, MessageVersion version, FaultConverter faultConverter)
       at System.ServiceModel.Channels.ServiceChannel.HandleReply(ProxyOperationRuntime operation, ProxyRpc& rpc)
       at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout)
       at System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation)
       at System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message)
    Exception rethrown at [0]:
       at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
       at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
       at FRB.EC.AdminService.ConsoleTester.svcRef.IAdminService.GetDispositionStatusTypeList()
       at FRB.EC.AdminService.ConsoleTester.svcRef.AdminServiceClient.GetDispositionStatusTypeList() in C:\SourceEagleConnect\EagleConnect\Dev\WCFServices\FRB.EC.AdminService.ConsoleTester\Service References\svcRef\Reference.cs:line 2459
       at FRB.EC.AdminService.ConsoleTester.ConsoleProgram.GetDispositionStatusTypeList() in C:\SourceEagleConnect\EagleConnect\Dev\WCFServices\FRB.EC.AdminService.ConsoleTester\ConsoleProgram.cs:line 565
       at FRB.EC.AdminService.ConsoleTester.ConsoleProgram.ExecuteNewRelease103QueryMethods() in C:\SourceEagleConnect\EagleConnect\Dev\WCFServices\FRB.EC.AdminService.ConsoleTester\ConsoleProgram.cs:line 189
       at FRB.EC.AdminService.ConsoleTester.ConsoleProgram.Main(String[] args) in C:\SourceEagleConnect\EagleConnect\Dev\WCFServices\FRB.EC.AdminService.ConsoleTester\ConsoleProgram.cs:line 76
       at System.AppDomain._nExecuteAssembly(RuntimeAssembly assembly, String[] args)
       at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args)
       at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly()
       at System.Threading.ThreadHelper.ThreadStart_Context(Object state)
       at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean ignoreSyncCtx)
       at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)
       at System.Threading.ThreadHelper.ThreadStart()
    I am also posting the web.config/app.config, but I would rather not focus on that since there were absolutely no changes to it between the time it was working and the time it began failing. 
    Client app.config
    <?xml version=»1.0″ encoding=»utf-8″ ?>
    <configuration>
      <connectionStrings>
      </connectionStrings>
      <system.serviceModel>
        <behaviors>
          <serviceBehaviors>
            <behavior name=»ServiceBehavior»>
              <serviceMetadata httpGetEnabled=»true»/>
              <serviceDebug includeExceptionDetailInFaults=»false»/>
              <serviceAuthorization impersonateCallerForAllOperations=»true»/>
            </behavior>
          </serviceBehaviors>
          <endpointBehaviors>
            <behavior name=»FRB.AllowImpersonate»>
              <clientCredentials>
                <windows allowedImpersonationLevel=»Impersonation»/>
              </clientCredentials>
            </behavior>
          </endpointBehaviors>
        </behaviors>
        <bindings>
          <wsHttpBinding>
            <binding name=»WSHttpBinding_IAdminService» closeTimeout=»00:01:00″
              openTimeout=»00:01:00″ receiveTimeout=»00:10:00″ sendTimeout=»00:01:00″
              bypassProxyOnLocal=»false» transactionFlow=»false» hostNameComparisonMode=»StrongWildcard»
              maxBufferPoolSize=»524288″ maxReceivedMessageSize=»5565536″
              messageEncoding=»Text» textEncoding=»utf-8″ useDefaultWebProxy=»true»
              allowCookies=»false»>
              <readerQuotas maxDepth=»32″ maxStringContentLength=»8192″ maxArrayLength=»16384″
                maxBytesPerRead=»4096″ maxNameTableCharCount=»16384″ />
              <reliableSession ordered=»true» inactivityTimeout=»00:10:00″
                enabled=»false» />
              <security mode=»Message»>
                <transport clientCredentialType=»Windows» proxyCredentialType=»None»
                  realm=»» />
                <message clientCredentialType=»Windows» negotiateServiceCredential=»true»
                  algorithmSuite=»Default» />
              </security>
            </binding>
          </wsHttpBinding>
        </bindings>
            <client>
                  <endpoint address=»http://localhost:3588/AdminService.svc» binding=»wsHttpBinding»
                        bindingConfiguration=»WSHttpBinding_IAdminService» contract=»svcRef.IAdminService»
                        name=»WSHttpBinding_IAdminService»>
                        <identity>
                              <dns value=»localhost» />
                        </identity>
                  </endpoint>
            </client>
        </system.serviceModel>
    </configuration>
    web.config of WCF service:
      <?xml version=»1.0″?>
    <configuration>
        <configSections>
        <section name=»FRB.Diagnostics» type=»FRB.Diagnostics.Configuration.UkadcDiagnosticsSection, FRB.Diagnostics»/>
      </configSections>
        <appSettings>
           <!— whatever goes here —>
        </appSettings>
        <!— connection string section —>
      <connectionStrings>
        <add name=»log» connectionString=»Data Source=myserver;Initial Catalog=ECWCFLOG_SharedDev;User ID=myuser;Password=mypass;MultipleActiveResultSets=True» providerName=»System.Data.SqlClient»/>
        <add name=»DBConn» connectionString=»Data Source=myserver;Initial Catalog=ECData_SharedDev;User ID=myuser;Password=mypass;MultipleActiveResultSets=True» providerName=»System.Data.SqlClient»/>
        <add name=»EagleConnectEntities» connectionString=»metadata=res://*/EagleConnect.csdl|res://*/EagleConnect.ssdl|res://*/EagleConnect.msl;provider=System.Data.SqlClient;provider connection string=&quot;Data Source=myserver;Initial
    Catalog=ECData_SharedDev;User ID=myuser;Password=mypass;MultipleActiveResultSets=True&quot;» providerName=»System.Data.EntityClient»/>
      </connectionStrings>
        <!— FRB.Diagnostics logging section —>
        <FRB.Diagnostics>
            <sqlTraceListeners>
                <sqlTraceListener name=»sqlTraceListenerSettings»
                            connectionStringName=»log»
                            commandText=»INSERT INTO LogStore VALUES(@Source, @ActivityId, @ProcessId, @ThreadId, @EventType, @Message, @Timestamp)»
                            commandType=»Text»>
                    <parameters>
                        <parameter name=»@Source» propertyToken=»{Source}»/>
                        <parameter name=»@ActivityId» propertyToken=»{ActivityId}»/>
                        <parameter name=»@ProcessId» propertyToken=»{ProcessId}»/>
                        <parameter name=»@ThreadId» propertyToken=»{ThreadId}»/>
                        <parameter name=»@EventType» propertyToken=»{EventType}» callToString=»true»/>
                        <parameter name=»@Message» propertyToken=»{Message}»/>
                        <parameter name=»@Timestamp» propertyToken=»{DateTime}»/>
              <!— <parameter name=»@UserId» propertyToken=»{WindowsIdentity}»/> —>
            </parameters>
                </sqlTraceListener>
            </sqlTraceListeners>
            <smtpTraceListeners>
                <smtpTraceListener name=»smtpTraceListenerSettings»
                             host=»vssmtp»
                             port=»25″
                             from=»[email protected]»
                             to=»[email protected]»
                             subject=»AdminService Logging Event: {EventType}, {MachineName}»
                             body=»{Message}&#xA;=======&#xA;Process={ProcessId},&#xA;Thread={ThreadId},&#xA;ActivityId={ActivityId}»/>
            </smtpTraceListeners>
        </FRB.Diagnostics>
        <!— System.Diagnostics logging section —>
        <system.diagnostics>
            <sources>
                <source name=»FRB.EC.AdminService» switchValue=»All»>
                    <listeners>
                        <clear/>
                        <add name=»ods»/>
                        <add name=»smtp»/>
                        <add name=»sql»/>
                    </listeners>
                </source>
                <source name=»System.ServiceModel» switchValue=»Off» propagateActivity=»true»>
                    <listeners>
                        <add name=»ignored» type=»System.Diagnostics.ConsoleTraceListener»/>
                    </listeners>
                </source>
            </sources>
            <sharedListeners>
                <!— OutputDebugStringTraceListener —>
                <add name=»ods»
               type=»FRB.Diagnostics.Listeners.OutputDebugStringTraceListener, FRB.Diagnostics»
               initializeData=»{ActivityId}|{EventType}: {Message} — {DateTime}, Process={ProcessId}, Thread={ThreadId}»/>
                <!— SqlTraceListener —>
                <add name=»sql»
               type=»FRB.Diagnostics.Listeners.SqlTraceListener, FRB.Diagnostics»
               initializeData=»sqlTraceListenerSettings»
               traceOutputOptions=»Timestamp»/>
                <!— SmtpTraceListener —>
                <add name=»smtp»
               type=»FRB.Diagnostics.Listeners.SmtpTraceListener, FRB.Diagnostics»
               initializeData=»smtpTraceListenerSettings»>
                       <filter type=»System.Diagnostics.EventTypeFilter»
                       initializeData=»Error»/>
                </add>
            </sharedListeners>
            <trace autoflush=»true»/>
        </system.diagnostics>
        <system.web>
        <compilation debug=»true» targetFramework=»4.0″>
        </compilation>
            <roleManager enabled=»true» defaultProvider=»AspNetWindowsTokenRoleProvider»/>
        </system.web>
        <system.serviceModel>
            <services>
                <service name=»FRB.EC.AdminService.AdminService»
                   behaviorConfiguration=»FRB.EC.AdminService.AdminServiceBehavior»>
                    <!— Service Endpoints —>
                    <endpoint address=»» binding=»wsHttpBinding»
                      bindingConfiguration=»wsHttpEndpointBinding»
                      contract=»FRB.EC.AdminService.IAdminService»>
                        <!—
                  Upon deployment, the following identity element should be removed or replaced to reflect the
                  identity under which the deployed service runs. 
                  If removed, WCF will infer an appropriate identity automatically.
              —>
                        <identity>
                            <dns value=»localhost»/>
                        </identity>
                    </endpoint>
                    <endpoint address=»mex» binding=»mexHttpBinding» contract=»IMetadataExchange»/>
                </service>
            </services>
            <bindings>
                <wsHttpBinding>
                    <binding name=»wsHttpEndpointBinding»
                     maxBufferPoolSize=»2147483647″
                     maxReceivedMessageSize=»500000000″>
                        <readerQuotas maxDepth=»2147483647″
                            maxStringContentLength=»2147483647″
                            maxArrayLength=»2147483647″
                            maxBytesPerRead=»2147483647″
                            maxNameTableCharCount=»2147483647″/>
                        <security>
                            <message clientCredentialType=»Windows»/>
                        </security>
                    </binding>
                </wsHttpBinding>
            </bindings>
            <behaviors>
                <serviceBehaviors>
                    <behavior name=»FRB.EC.AdminService.AdminServiceBehavior»>
                        <!— To avoid disclosing metadata information, set the value below to false and
                   remove the metadata endpoint above before deployment —>
                        <serviceMetadata httpGetEnabled=»true»/>
                        <!— To receive exception details in faults for debugging purposes, set the value below to true. 
                   Set to false before deployment to avoid disclosing exception information —>
                        <serviceDebug includeExceptionDetailInFaults=»true»/>
                        <serviceCredentials>
                        </serviceCredentials>
                        <!—<serviceAuthorization principalPermissionMode=»UseAspNetRoles»
                    roleProviderName=»AspNetWindowsTokenRoleProvider»/>—>
                        <serviceAuthorization principalPermissionMode=»UseWindowsGroups»
                                    impersonateCallerForAllOperations=»true»/>
                    </behavior>
                    <behavior name=»FRB.EC.AdminService.IAdminServiceTransportBehavior»>
                        <!— To avoid disclosing metadata information, set the value below to false and
                   remove the metadata endpoint above before deployment —>
                        <serviceMetadata httpGetEnabled=»true»/>
                        <!— To receive exception details in faults for debugging purposes, set the value below to true. 
                   Set to false before deployment to avoid disclosing exception information —>
                        <serviceDebug includeExceptionDetailInFaults=»false»/>
                        <serviceCredentials>
                            <clientCertificate>
                                <authentication certificateValidationMode=»PeerTrust»/>
                                <!—<authentication certificateValidationMode=»Custom» customCertificateValidatorType=»DataFactionServices.FRBX509CertificateValidator»/>—>
                            </clientCertificate>
                            <serviceCertificate findValue=»WCfServer»
                                    storeLocation=»LocalMachine»
                                    storeName=»My» x509FindType=»FindBySubjectName»/>
                        </serviceCredentials>
                    </behavior>
                </serviceBehaviors>
            </behaviors>
            <serviceHostingEnvironment multipleSiteBindingsEnabled=»true»/>
        </system.serviceModel>
        <system.webServer>
            <modules runAllManagedModulesForAllRequests=»true»/>
        </system.webServer>
    </configuration>
    Thanks for any help.
    Neal

    I think I found it… this is sure a strange error for what is really happening.
    Apparently it had happened to me before, and fortuantely, I actually added the following comment:
                // Above is related to the WCFLOG SQL Diagnostics Trace 
                // If you get error here an inner exception «requested registry access is not allowed»
                // inside exception «type initializer for System.Data.SqlClient.SqlConnection»
                // then make sure you have impersonation enabled in your client.
                // See AdminConsole web.config or FRB.EC.AdminService.ConsoleTester.app.config for examples
    Now I think I will do a try catch and spit out the same text.
    Still testing to assure that this really was the issue.
          <endpointBehaviors>
            <behavior name=»FRB.AllowImpersonate «>
              <clientCredentials>
                <windows allowedImpersonationLevel=»Impersonation»/>
              </clientCredentials>
            </behavior>
          </endpointBehaviors>
    The line below in BOLD below is what somehow seemed to disappear from my app.config — probably due to a TFS human error — still checking that also:
            <client>
                  <endpoint address=»http://localhost:4998/AdminService.svc»
                                  behaviorConfiguration=»FRB.AllowImpersonate»
                                  binding=»wsHttpBinding»
                                  bindingConfiguration=»WSHttpBinding_IAdminService»
                                 contract=»svcRef.IAdminService»
                            name=»WSHttpBinding_IAdminService»>
                        <identity>
                              <dns value=»localhost» />
                        </identity>
                  </endpoint>
            </client>
    Here’s how I «idiot-proofed» this error for now, to give an error that actually at least points to a solution:
            public SqlDataAccessCommand(string connectionString, string commandText, CommandType commandType)
                try
                    _connection = new SqlConnection(connectionString);
                    // Above is related to the WCFLOG SQL Diagnostics Trace  
                    // If you get error here an inner exception «requested registry access is not allowed»
                    // inside exception «type initializer for System.Data.SqlClient.SqlConnection»
                    // then make sure you have impersonation enabled in your client.
                    // See AdminConsole web.config or FRB.EC.AdminService.ConsoleTester.app.config for examples
                catch (Exception ex)
                    if (ex.ToString().Contains(«The type initializer for»))
                    throw new System.ApplicationException(@»
                    Your client app <endpoint> must be cofigured have a
                  ‘behaviorConfiguration’ attribute like this:
                    behaviorConfiguration=’FRB.AllowImpersonate’
                   that points back to a behavior that has this syntax:         
              <behavior name=’FRB.AllowImpersonate’>
                 <clientCredentials>
                     <windows allowedImpersonationLevel=’Impersonation’/>
                 </clientCredentials>
              </behavior>
              «, ex);
                   else
                        throw ex;
                _command = _connection.CreateCommand();
                _command.CommandText = commandText;
                _command.CommandType = commandType;
                // TODO _command.CommandTimeout = ;
    Neal

  • The components for communicating with FTP servers are not installed.

    I’m running VS 2013 and when I try to publish to ftp site I get the following message. «Unable to create the Web site ‘ftp://xx/’. The components for communicating with the FTP servers are not installed.»   It has been running fine. I
    can publish to file system, web sites etc, just not through the ftp settings. I can access the ftp sites from my system, using other programs. It is not trying to connect to the ftp site at all.

    Hi paaccess,
    Glad to receive your reply.
    According to your description, since we can publish an application to ftp site in Visual Studio Prof 2013 in our side. Therefore, to further make sure if the issue is related to the VS IDE issue. We suggest
    you try to publish to ftp site on another machine you installed same version of VS Prof 2013 and then check it again.
    If you can publish on another machine, I suggest may need to re-download the
    VS Prof 2013 from Microsoft website and then install it again on your local machine.
    If you still could not publish on another machine, I think that the issue is not related to the VS2013 IDE issue. If possible, I still suggest you post the issue directly to the IIS.NET Forum:
    http://forums.iis.net/,
    it will better help you solve the issue.
    Thanks for your understanding.
    Have a nice day!
    Best Regards.
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click HERE to participate the survey.

  • Components of BI Contents LIS Datasources are not matching

    Hi All,
    We have two R/3 Systems with the config’s and SP’s as
    Version — 4.7 SP 27 —>  fields not found
    Version — 4.7 SP 28 —
    > fields found
    When we go into LBWE of first one, i have only 22 fields but whn i go to second system data fields are 66.
    Datasource name — 2LIS_17_I0NOTIF.
    Please advice,
    Regards,
    Karthik

    i have found out the answer as some issues in Views that have added, usage of maintenance pool fields

  • Table are not prefixed with Schema in  SQL request — Unable to get Data

    I began this new thread because I closed the [previous one|Unable to get data (DSN connection); a little bit early, I believed it was OK but no the problem still here.
    First my architecture :
    Oracle 9g
    +500 Reports made under CR developper 8.5 or 9.0
    Report opened in VB .net application, framework 2.0 using CR runtime 8.5 and 9.0
    We want to upgrade CR version to 2008, so modification of reports will be done with CR 2008 Developper, and we want to
    use only CR 2008 runtime.
    The problem :
    Everything works fine in CR Developer, but the same report with the same parameters failed when called inside .net.
    The error is «Unable to get data», the database connection is OK but the queries mades from inside the report are wrong :
    The tables/views in the from statement are not prefixed with the Schema, so Oracle don’t find them.
    Example (SQL monitoring done with TOAD)
    Execution of postes.rpt report directly in CR :
    Timestamp: 10:30:03.881
    Successful logon attempt (session tag: 0x6464CB8)
    username: ‘APPLI_HUET’; database: ‘DEV’
    SELECT …
    FROM  «COMMUN».»ETAB» «ETAB» INNER JOIN «GESTION_DES_TEMPS».»POSTES» «POSTES»
    ON «ETAB».»N_ETAB»=»POSTES».»N_ETAB»
    WHERE  «POSTES».»N_ETAB»=2 ORDER BY «POSTES».»N_POSTE»
    Timestamp: 10:50:29.178
    Logoff (session tag: 0x6464CB8).
    Same report, same authentication but throught .net program :
    Timestamp: 11:01:24.569
    Successful logon attempt (session tag: 0xA93FC38)
    username: ‘APPLI_HUET’; database: ‘DEV’
    SELECT …
    FROM   «ETAB» «ETAB» INNER JOIN «POSTES» «POSTES»
    ON «ETAB».»N_ETAB»=»POSTES».»N_ETAB» WHERE  «POSTES».»N_ETAB»=2 ORDER
    BY «POSTES».»N_POSTE»
    Runtime error occurred: 942 (ORA-00942: Table ou vue inexistante)
    The .net code :
    Dim _report As New ReportDocument()
    _report.Load(«report.rpt», OpenReportMethod.OpenReportByDefault)
    Dim myConnectionInfo As ConnectionInfo = New ConnectionInfo()
    myConnectionInfo.ServerName = «DSN_file»
    myConnectionInfo.UserID = p_Userid
    myConnectionInfo.Password = p_Password
    ‘ to see code in this method se my original post
    SetDBLogonForReport(myConnectionInfo, _report)
    SetDBLogonForSubreports(myConnectionInfo, _report)
    Dim frmViewer As New CrystalReportViewer
    frmViewer.CrystalReportViewer1.ReportSource = _report
    frmViewer.Show()
    Any ideas ?

    Thanks for the and sorry but I don’t understand.
    I’ve made a research of Location on this forum the more intersting thread I’ve found is rpt-files do not function anymore after deploying to a different database, but I still don’t understand.
    I take a look at all code sample and I can’t found anything.
    You say that .Location need to be set, indeed Location property of CrystalDecisions.CrystalReports.Engine.Table object only contains table name.
    I tried to overrides this value by the fully qualified table name (ie Schema.Table, for example GESTION_DES_TEMPS.POSTES), and it work  BUT it wouldn’t be the solution, my code is designed to be generic, I can’t have a database to know wich schema add before differents table name.
    Why when we execute the report directly in CR 2008 developper we don’t have to redefine the table location ?
    Another test :
    I’ve made a new report directly in CR 2008 with a DSN, launch it in .net with the same DSN (server) : OK
    Then I launch it in .net with another DSN, it work also.
    Why report done with Crystal 8.5 or 9.0 have this problem ?
    I’me gonna be mad….
    Edited by: Yoann DAVID on Jan 8, 2010 3:32 PM

  • Master data load: texts are not loaded

    Hi friends,
    Trying to load BW Hierarchy(0COSTCENTER) to BPC dimension(P_CC).
    Loadedd master data & text data using package «Import master data from BI infoobject»(/CPMB/IMPORT_IOBJ_MASTER), but EVdescription (texts) are not uploaded ino BPC dimension (P_CC).
    Because of above error, when i try to load hierarchy(0costcenter), sytem throwoing one more error(JScrpit evaluation error).
    Now i want to load texts into P_CC. ours is bpc 75nw sp10.
    Found 2 notes, but these are related to older support packges
    1462732 u2013 DM: text node descriptions canu2019t be imported.
    1531601 — Incident 737084 / 2010 / text nodes aren’t loaded
    Transformation file:
    *OPTIONS
    FORMAT = DELIMITED
    HEADER = YES
    DELIMITER = TAB
    AMOUNTDECIMALPOINT = .
    SKIP = 0
    SKIPIF =
    VALIDATERECORDS=YES
    CREDITPOSITIVE=YES
    MAXREJECTCOUNT=-1
    ROUNDAMOUNT=
    *MAPPING
    ID=ID
    CURRENCY=0OBJ_CURR
    *CONVERSION
    DM package run:
    Infoobject: 0COSTCENTER
    set selection: Attributes Controlling area = SP00
                           Hierarhcy: import text node(yes), selected hierarchy, version(empty),memberid(SP001170),level(not filled)
                           language: English, medium description,
                          attiribute list: currency(0OBJ_CURRENCY),controlling area
    fileter by attributes or hierarhies option selection,
    Mode: Update
    Format: internal
    Dimension: P_cc
    package ended with error
    Failed to write text of master data; check the error message
    checked BPC dim, only member ID & currency is updated, but not evdescription.
    Can you please share valuable inputs.
    thanks,
    naresh

    resolved problem.
    Packages given bpc7.5 nw sp10 are is exactly working.
    Mapping section:
    ID=0CO_AREA+ID
    CURRENCY=0OBJ_CURRENCY
    becoz base members are automatically added with controlling area in BW hierarchy on 0costcenter.
    Followed method given in how to guide.

  • I tried to install Elements 8 on my new MacBookPro, I have the original CD and the serial number, but it won’t work. I get error message «some of the application components are missing. Please reinstall the application». I did, no result however. Applicat

    !

    Traute Redlich did you remove Photoshop Elements 8 first using the uninstaller located in the Applications/Utilities/Adobe Installers folder?  What operating system are you using?

  • System.Data.SqlClient.SqlException (0x80131904): SQL Server detected a logical consistency-based I/O error: incorrect checksum

    Hello,
    I am migrating client’s database to my hosted environment, the client runs
    SQL Server 2008 R2, and we run SQL Server 2014.
    I am stuck on restoring one log file, which left below error message when I restore it:
    Restoring files
      DBFile_20150401030954.trn
    Error Message: System.Data.SqlClient.SqlException (0x80131904): SQL Server detec
    ted a logical consistency-based I/O error: incorrect checksum (expected: 0x512cb
    ec3; actual: 0x512dbec3). It occurred during a read of page (1:827731)
    in databa
    se ID 49 at offset 0x000001942a6000 in file ‘F:\MSSQL12.INSTANCE9\MSSQL\Data\Ody
    sseyTSIAKL_Data.mdf’.  Additional messages in the SQL Server error log or system
     event log may provide more detail. This is a severe error condition that threat
    ens database integrity and must be corrected immediately. Complete a full databa
    se consistency check (DBCC CHECKDB). This error can be caused by many factors; f
    or more information, see SQL Server Books Online.
    RESTORE LOG is terminating abnormally.
       at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolea
    n breakConnection, Action`1 wrapCloseInAction)
       at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception
    , Boolean breakConnection, Action`1 wrapCloseInAction)
       at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObj
    ect stateObj, Boolean callerHasConnectionLock, Boolean asyncClose)
       at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand
     cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler,
    TdsParserStateObject stateObj, Boolean& dataReady)
       at System.Data.SqlClient.SqlDataReader.TryConsumeMetaData()
       at System.Data.SqlClient.SqlDataReader.get_MetaData()
       at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, Run
    Behavior runBehavior, String resetOptionsString)
       at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBe
    havior, RunBehavior runBehavior, Boolean returnStream, Boolean async, Int32 time
    out, Task& task, Boolean asyncWrite, SqlDataReader ds)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehav
    ior, RunBehavior runBehavior, Boolean returnStream, String method, TaskCompletio
    nSource`1 completion, Int32 timeout, Task& task, Boolean asyncWrite)
       at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehav
    ior, RunBehavior runBehavior, Boolean returnStream, String method)
       at System.Data.SqlClient.SqlCommand.ExecuteScalar()
       at OnBoardingTrnRestore.FileRestorer.FileIsRestored(SqlConnection connection,
     String sourceBackupFileName, String sourceDatabaseName, String destinationDatab
    aseName, String databaseName, String strFileName) in c:\Dev\WiseCloud\OnBoarding
    TrnRestore\OnBoardingTrnRestore\FileRestorer.cs:line 223
    ClientConnectionId:6f583f98-9c23-4936-af45-0d7e9a9949ea
    Finished
    I have run restore filelistonly and verifyonly in both client and my box, and both worked well:
    XXX_Data D:\Program Files (x86)\XXX\Data\YYY_Data.mdf
    restore filelistonly:
    D PRIMARY
    70922469376 35184372080640
    1 0
    0 00000000-0000-0000-0000-000000000000
    0 0
    0 512 1
    NULL 279441000014839500242
    66CC6D17-575C-41E5-BB58-3FB4D33E288C
    0 1 NULL
    XXX_Log E:\Program Files (x86)\XXX\Log\YYY_Log.ldf
    L NULL
    31985762304 35184372080640
    2 0
    0 00000000-0000-0000-0000-000000000000
    0 0
    0 512 0
    NULL 0
    00000000-0000-0000-0000-000000000000 0
    1 NULL
    restore verifyonly:
    Attempting to restore this backup may encounter storage space problems. Subsequent messages will provide details.
    The path specified by «D:\Program Files (x86)\XXX\Data\YYY_Data.mdf» is not in a valid directory.
    Directory lookup for the file «E:\Program Files (x86)\XXX\Log\YYY_Log.ldf» failed with the operating system error 3(The system cannot find the path specified.).
    The backup set on file 1 is valid.
    Dbcc checkdb also confirmed there is no error in client sql server database.
    dbcc checkdb (XXX, NOINDEX) 
    Results as follows:
    DBCC results for ‘XXX’.
    Warning: NO_INDEX option of checkdb being used. Checks on non-system indexes will be skipped.
    Service Broker Msg 9675, State 1: Message Types analyzed: 17.
    Service Broker Msg 9676, State 1: Service Contracts analyzed: 9.
    Service Broker Msg 9667, State 1: Services analyzed: 7.
    Service Broker Msg 9668, State 1: Service Queues analyzed: 7.
    Service Broker Msg 9669, State 1: Conversation Endpoints analyzed: 0.
    Service Broker Msg 9674, State 1: Conversation Groups analyzed: 0.
    Service Broker Msg 9670, State 1: Remote Service Bindings analyzed: 0.
    Service Broker Msg 9605, State 1: Conversation Priorities analyzed: 0.
    DBCC results for ‘sys.sysrscols’.
    There are 23808 rows in 350 pages for object «sys.sysrscols».
    DBCC results for ‘BMBoard’.
    There are 0 rows in 0 pages for object «BMBoard».
    DBCC results for ‘CusOutturnHeader’.
    There are 0 rows in 0 pages for object «CusOutturnHeader».
    CHECKDB found 0 allocation errors and 0 consistency errors in database ‘XXX’.
    DBCC execution completed. If DBCC printed error messages, contact your system administrator.
    We use ftp to transfer the log files from the another country to here, I confirmed the file’s MD5(checksum) is same as the copy in client’s environment, we have tried to upload the file a couple of times, same outcome.
    The full backup is fine, I have successfully restored a series log backups prior to this file.
    Has anyone seen this issue before? It is strange, all information indicates the file is good,but somehow it goes wrong.
    Below are the version details:
    Client: 
    MICROSOFT SQL SERVER 2008 R2 (SP2) — 10.50.4000.0 (X64) 
    My environment:
    Microsoft SQL Server 2014 — 12.0.2480.0 (X64) 
    Jan 28 2015 18:53:20 
    Copyright (c) Microsoft Corporation
    Enterprise Edition (64-bit) on Windows NT 6.3 <X64> (Build 9600: )
    Thanks,
    Albert

    Error Message: System.Data.SqlClient.SqlException (0x80131904): SQL Server detec
    ted a logical consistency-based I/O error: incorrect checksum (expected: 0x512cb
    ec3; actual: 0x512dbec3). It occurred during a read of page (1:827731)
    in databa
    se ID 49 at offset 0x000001942a6000 in file ‘F:\MSSQL12.INSTANCE9\MSSQL\Data\Ody
    sseyTSIAKL_Data.mdf’.  Additional messages in the SQL Server error log or system
     event log may provide more detail. This is a severe error condition that threat
    ens database integrity and must be corrected immediately.
    Hi Albert,
    The above error message usually indicates that there is a problem with underlying storage system or the hardware or a driver that is in the path of the I/O request. You can encounter this error when there are inconsistencies in the file system or if the database
    file is damaged.
    Besides other suggestions, consider to use the
    SQLIOSim utility to find out if these errors can be reproduced outside of regular SQL Server I/O requests and change
    your databases to use the PAGE_VERIFY CHECKSUM option.
    Reference:
    http://support.microsoft.com/en-us/kb/2015756
    https://msdn.microsoft.com/en-us/library/aa337274.aspx?f=255&MSPPError=-2147217396
    Thanks,
    Lydia Zhang
    Lydia Zhang
    TechNet Community Support

  • My system data is almost full!

    what consists of system data I have deleted all non needed stuff and it’s still not going dowm

    freezing and running slow prompted me to ask a versizon person in costco they said free up apps ect so I did I have deleted everything i could nothing has worked
    Dana
    Private info removed as required by the Terms of Service.
    Message was edited by: Admin Moderator

  • The SQL Server error code 0x80004005 login timeout expired is a common error that occurs when trying to connect to a SQL Server instance. This error is usually caused by a problem with the connection settings or a problem with the SQL Server instance itself. There are several reasons why this error may occur.

    1. Incorrect SQL Server connection string

    One of the most common causes of login issues is an incorrect connection string. This can happen when the server name, port number, or login credentials are incorrect. To resolve this issue, double-check your connection string and make sure that it is correct.

    For example, in this tutorial on how to connect to SQL Server using Python, a SQL Server connection string looks like this:

    import pyodbc
    
    connection = pyodbc.connect('Driver={SQL Server};'
                                'Server=localhost;'
                                'Database=Expert-Only;'
                                'Trusted_Connection=yes;')
    

    Check the connection string to avoid SQL Server error code 0x80004005 login timeout expired

    Check the connection string to avoid SQL Server error code 0x80004005 login timeout expired

    Whereas with SSIS connections, a connection string looks like this. Exemple taken from the ConnectionString property of a Native OLE DB 11.0 conneciton to SQL Server.

    Data Source=localhost;Initial Catalog=Expert-Only;Provider=SQLNCLI11.1;Integrated Security=SSPI;Application Name=SSIS-Package1-{49247E1C-7749-4A4C-B9BC-8A83F7A1190F}localhost.Expert-Only;Auto Translate=False;

    2. SQL Server error login timeout instance issue

    Another common cause of the SQL Server error login timeout expired is a problem with the SQL Server instance. I.e., on server side. This can be caused by a number of things such as the SQL Server service not running, the server being down for maintenance, or a problem with the network connection.

    In this case, you should check the status of the SQL Server service, check the server’s event logs, and check the network connection.

    3. Client side settings not properly set

    A third cause of this error is a problem with the client-side settings. This can be caused by a problem with the client-side network settings or a problem with the client-side firewall. To resolve this issue, check the client-side network settings and make sure that they are configured correctly, and check the client-side firewall to make sure that it is not blocking the connection.

    Conclusion on the SQL Server error login timeout

    In conclusion, the SQL Server error code 0x80004005 login timeout expired is a common error that can be caused by several different issues. By checking the connection settings, the SQL Server instance, and the client-side settings, you can often resolve this error and restore the connection to the SQL Server instance.

    More tutorials on SQL Server and T-SQL

    • SQL Server data types with code examples
    • Manage strings with more than 8000 characters
    • Store a SQL Server column in a variable
    • Create a SQL Server database with a script

    To go further and use programming to manage data, you can use Python and T-SQL to manage SQL Server tables and data.

    The SQL Server error code 0x80004005 login timeout expired is a common error that occurs when trying to connect to a SQL Server instance. This error is usually caused by a problem with the connection settings or a problem with the SQL Server instance itself. There are several reasons why this error may occur.

    1. Incorrect SQL Server connection string

    One of the most common causes of login issues is an incorrect connection string. This can happen when the server name, port number, or login credentials are incorrect. To resolve this issue, double-check your connection string and make sure that it is correct.

    For example, in this tutorial on how to connect to SQL Server using Python, a SQL Server connection string looks like this:

    import pyodbc
    
    connection = pyodbc.connect('Driver={SQL Server};'
                                'Server=localhost;'
                                'Database=Expert-Only;'
                                'Trusted_Connection=yes;')
    

    Check the connection string to avoid SQL Server error code 0x80004005 login timeout expired

    Check the connection string to avoid SQL Server error code 0x80004005 login timeout expired

    Whereas with SSIS connections, a connection string looks like this. Exemple taken from the ConnectionString property of a Native OLE DB 11.0 conneciton to SQL Server.

    Data Source=localhost;Initial Catalog=Expert-Only;Provider=SQLNCLI11.1;Integrated Security=SSPI;Application Name=SSIS-Package1-{49247E1C-7749-4A4C-B9BC-8A83F7A1190F}localhost.Expert-Only;Auto Translate=False;

    2. SQL Server error login timeout instance issue

    Another common cause of the SQL Server error login timeout expired is a problem with the SQL Server instance. I.e., on server side. This can be caused by a number of things such as the SQL Server service not running, the server being down for maintenance, or a problem with the network connection.

    In this case, you should check the status of the SQL Server service, check the server’s event logs, and check the network connection.

    3. Client side settings not properly set

    A third cause of this error is a problem with the client-side settings. This can be caused by a problem with the client-side network settings or a problem with the client-side firewall. To resolve this issue, check the client-side network settings and make sure that they are configured correctly, and check the client-side firewall to make sure that it is not blocking the connection.

    Conclusion on the SQL Server error login timeout

    In conclusion, the SQL Server error code 0x80004005 login timeout expired is a common error that can be caused by several different issues. By checking the connection settings, the SQL Server instance, and the client-side settings, you can often resolve this error and restore the connection to the SQL Server instance.

    More tutorials on SQL Server and T-SQL

    • SQL Server data types with code examples
    • Manage strings with more than 8000 characters
    • Store a SQL Server column in a variable
    • Create a SQL Server database with a script

    To go further and use programming to manage data, you can use Python and T-SQL to manage SQL Server tables and data.

    • Remove From My Forums
    • Question

    • Hi,

      I have received the following error with when executing an SSIS package with a SQL Server database as a data source where I have read only access; —

      Error: 0xC0202009 at my_SSIS_component, my_database: SSIS Error Code

      DTS_E_OLEDBERROR.  An OLE DB error has occurred.

      Error code: 0x80004005.
      An OLE DB record is available.  Source: «Microsoft SQL Server Native Client 10.0» 

      Hresult: 0x80004005  Description: «Protocol error in TDS stream».

      An OLE DB record is available.  Source: «Microsoft SQL Server Native Client 10.0»

      Hresult: 0x80004005  Description: «Communication link failure».
      An OLE DB record is available.  Source: «Microsoft SQL Server Native Client 10.0»

      Hresult: 0x80004005  Description: «TCP Provider: An existing connection was forcibly closed by the remote host.
      «.
      An OLE DB record is available.  Source: «Microsoft SQL Server Native Client 10.0»  Hresult: 0x80004005  Description: «Communication link failure».
      An OLE DB record is available.  Source: «Microsoft SQL Server Native Client 10.0»  Hresult: 0x80004005  Description: «TCP Provider: The semaphore timeout period has expired.
      «.
      Error: 0xC0047038 at my_SSIS_component, SSIS.Pipeline: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED.  The PrimeOutput method on component «my_database» (1) returned error code 0xC0202009.  The component returned a failure code when the pipeline engine
      called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing.  There may be error messages posted before this with more information about the failure.

      Service operating system; —

      Microsoft SQL Server 2008 (SP2) — 10.0.4064.0 (X64)   Microsoft Corporation  Standard Edition (64-bit) on Windows NT 6.0 <X64> (Build 6002: Service Pack 2)
      Where I understand Windows NT 6.0 SP 2 is also known as Windows Server 2008 Service Pack 2.

      The error appears to occur intermittantly. Any guidance on how to arrive at a resolution would be greatly appreciated.

      Kind Regards,

      Kieran.


      If you have found any of my posts helpful then please vote them as helpful. Kieran Patrick Wood MCTS BI, PGD SoftDev (Open), MBCS, MCC http://uk.linkedin.com/in/kieranpatrickwood

      • Edited by

        Wednesday, October 5, 2011 2:04 PM

    Answers

    • Hi,

      The solution was that the VPN between a Microsoft TMG firewall and a Cisco ASA (mixed vendor) under load kept collapsing the VPN tunnel.
      The fix was to replace Microsoft TMG with a cisco Firewall so the VPN is now cisco-to-cisco, resulting in a much more stable connection. Also a router was purchased with a higher capacity to cope with the additional traffic.

      I then performed an initial test where I sucessfully copied a 1/2 tb file using Windows file manager from the source server to the destination server over the new Virtual Private network connection. Where performing a file copy when the problem initially
      arose is where I convinced my collegues that the core issue was network related and not related to the configuration of my SSIS package.

      After receiving the results of the successful 1/2 tb file copy. I then executed my SSIS package over night over this new VPN connection, and the package reported successful execution within SQL Server Job Agent.

      Hopefully people out there will use this solution and hopefully have less pain than me resolving it.


      If you have found any of my posts helpful then please vote them as helpful. Kieran Patrick Wood MCTS BI, PGD SoftDev (Open), MBCS http://uk.linkedin.com/in/kieranpatrickwood

      • Edited by
        Kieran Patrick Wood
        Monday, March 12, 2012 8:36 PM
      • Marked as answer by
        Kieran Patrick Wood
        Monday, March 12, 2012 8:36 PM
    • Remove From My Forums
    • Question

    • What does error code 0x80004005 mean?

    Answers

    • Karimullah,

      It’s unclear from your post if you’re even using SQL Server or Integration Services.  If you’re experiencing an issue with Norton, you should contact the vendor for assistance.  This forum is for questions and issues on SQL Server Integration Services.

    All replies

    • What are you trying to do? 0x80004005 could mean a variety of things from a failed login to an Access database that is exclusively locked by another process. Please provide additional details about your scenario.

    • At random places in my packages, I randomly (not always) get this general netwrok error (I am including the first line just to show the line right above the error line):

      Information: 0x400490F4 at Data Flow Task — my task 1, Lookup — my lookup task 1 [234]: component «Lookup — my lookup task 1» (234) has cached 13312 rows.

      Error: 0xC0202009 at Data Flow Task — my task 1, Lookup — my lookup task 1 [234]: An OLE DB error has occurred. Error code: 0x80004005

      An OLE DB record is available. Source: «Microsoft OLE DB Provider for SQL Server» Hresult: 0x80004005 Description: «[DBNETLIB][ConnectionRead (WrapperRead()).]General network error. Check your network documentation.»

      Error: 0xC020824E at Data Flow Task — my task 1, Lookup — my lookup task 1 [234]: OLE DB error occurred while populating internal cache. Check SQLCommand and SqlCommandParam properties.

      Error: 0xC004701A at Data Flow Task — my task 1, DTS.Pipeline: component «Lookup — my lookup task 1» (234) failed the pre-execute phase and returned error code 0xC020824E.

      FYI — I am using June CTP.

      thanks,
      Nitesh

    • i am trying to update my norton internet security antivirus

      but it is unable to update

      when i search for that one command is there to resolve when in run the command it is saying that code

      the command is         regsvr32 %windir%system32msxml3.dll

      error is call to dllregisterserver is failed with erro code 0x80004005

    • Karimullah,

      It’s unclear from your post if you’re even using SQL Server or Integration Services.  If you’re experiencing an issue with Norton, you should contact the vendor for assistance.  This forum is for questions and issues on SQL Server Integration Services.

    • Hi David,

      I am having a problem updating a fresh install of Windows XP SP2.  I was successful in the fresh install and the subsequent update to XP3.  Unfortunately I seem to be having issues now.  The updates download  with no problem. Unfortunately none are installed.  It basically freezes at the attempt to install,  when the dialogue box indicated initializating the install.
      The information, screen shots and copy of windows update log are at this location for your perusal.
      http://www.dslreports.com/forum/r20768460-XP-Pro-MS-Update-Not-Initializing

      All to say that error code in the title is the error code I am seeing in the windows update log!!

      Any suggestion or help you can give would be appreciated.

      Thanks!

    • Hello,

      Have you solve your issue ? I’m facing the same problem with my Integration services job since i did the upgrade on Visual Studio 2010, on the lookup specially.

      I have been searching for a while, but can’t find a solution.

    I have an SSIS package that is being executed by an SQL Job which runs twice a day. I recently updated the SSIS package by removing a where clause of a Select statement in it. Now the results have around 1800 rows compared tot he 650 of before. When I execute the new package on my local machine everything runs fine. But when I put it on the Prod server, it does not run and gives me Hresult: 0x80004005 Description: «Login timeout expired» error.

    This error is usually thrown when remote access is not enabled but it is. The Job is running under my account, so the rights should not be a problem. Also, the package was running without problems before and I only changed a where clause that makes the Table larger by a thousand rows, so I should not have a login timeout error for that.

    I know it is not the remaining space on the server because if I change the config file of the SSIS package and direct it the the production database, everything works fine.

    Again, that problem is bugging me because when I put the old package with the old where clause, everything works fine.

    Anyone has any idea what might be causing the problem?

    Here is the Log entry:

    Executed as user: Services. ...sion 9.00.3042.00 for 32-bit Copyright (C) Microsoft Corp 1984-2005. All rights reserved. Started: 1:49:21 PM Error: 2011-08-04 13:50:12.28 Code: 0xC0202009 Source: Brd Load Connection manager "DataBase" Description: SSIS Error Code DTS_E_OLEDBERROR. An OLE DB error has occurred. Error code: 0x80004005. An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80004005 Description: "Login timeout expired". An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80004005 Description: "An error has occurred while establishing a connection to the server. When connecting to SQL Server 2005, this failure may be caused by the fact that under the default settings SQL Server does not allow remote connections.". An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80004005 Description: "TCP Provider: A connection att... Process Exit Code 1. The step failed.

    SQL SERVER - Setup Closed with Exit Code 0x80004005 error Recently I was trying to help one of my clients to install Service Pack 3 for SQL Server 2008 R2 instance. Nothing was coming up when we were hitting setup.exe. I looked into my own blog and found Installation Log Summary File Location – 2012 – 2008 R2. But there was no file getting generated. I looked around of MSDN and found: https://msdn.microsoft.com/en-us/library/ms143702.aspx. The reason was there was exit code 0x80004005.

    It says that we should look into %TEMP% folder. So I went to Start > Run > %TEMP% and found sqlsetup.log file as below.

    03/01/2016 10:04:11.954 Setup launched
    03/01/2016 10:04:11.955 Attempting to determine media source
    03/01/2016 10:04:11.956 Media source value not specified on command line argument.
    03/01/2016 10:04:11.957 Setup is launched from media directly so default the value to the current folder.
    03/01/2016 10:04:11.957 Media source: D:SOFTWARESP3
    03/01/2016 10:04:11.958 Attempt to determine media layout based on file ‘ D:SOFTWARESP3mediainfo.xml’.
    03/01/2016 10:04:11.981 Media layout is detected as: Core
    03/01/2016 10:04:11.982 Not a slip stream media, so continuing to run setup.exe from media.
    03/01/2016 10:04:11.983 /? or /HELP or /ACTION=HELP specified: false
    03/01/2016 10:04:11.984 Help display: false
    03/01/2016 10:04:11.985 Checking to see if we need to install .Net version 3.5
    03/01/2016 10:04:11.985 Checking to see if we need to install MSI version 4.5
    03/01/2016 10:04:11.986 RedistMSI::GetExpectedBuildRevision – Setup expects MSI 4.5.6001.22159 at the minimum
    03/01/2016 10:04:11.987 Attempting to get Windows Installer version
    03/01/2016 10:04:11.988 Windows Installer version detected: 5.0.7601.18493
    03/01/2016 10:04:11.990 RedistMSI::IsVistaRTM – Not Vista RTM build
    03/01/2016 10:04:11.991 Required version of Windows Installer is already installed
    03/01/2016 10:04:11.992 .Net version 3.5 is already installed.
    03/01/2016 10:04:11.992 Windows Installer version 4.5 is already installed.
    03/01/2016 10:04:11.993 Patch related actions cannot be run from the local setup.exe, so continuing to run setup.exe from media.
    03/01/2016 10:04:11.993 Attempt to initialize SQL setup code group
    03/01/2016 10:04:11.994 Attempting to determine security.config file path
    03/01/2016 10:04:11.995 Checking to see if policy file exists
    03/01/2016 10:04:11.996 .Net security policy file does exist
    03/01/2016 10:04:11.997 Attempting to load .Net security policy file
    03/01/2016 10:04:12.000 Error: Cannot load .Net security policy file
    03/01/2016 10:04:12.001 Error: InitializeSqlSetupCodeGroupCore(64bit) failed
    03/01/2016 10:04:12.002 Error: InitializeSqlSetupCodeGroup failed: 0x80004005
    03/01/2016 10:04:12.002 Setup closed with exit code: 0x80004005
    ======================================================================

    All I can see is that there is something wrong with .NET security. I asked my .NET expert friend to know if there is any tool to reset the permission? He told CASPOL.EXE can be used to reset the policies.

    Caspol.exe (Code Access Security Policy Tool)

    So, we went into following directory “C:WINDOWSMicrosoft.NETFramework64v2.0.50727” and ran this command: –  caspol.exe -machine -reset

    C:WINDOWSMicrosoft.NETFramework64v2.0.50727>caspol.exe -machine -reset

    If it would have been a 32-bit machine, we would have run the same command under “C:WINDOWSMicrosoft.NETFrameworkv2.0.50727” folder.

    After doing above, the setup was able to start and finish as well.

    Reference: Pinal Dave (https://blog.sqlauthority.com)