Ошибка 094 325 xerox 6515

ehong

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Hi, I’m trying to follow along with your instructions but my Phaser 6510 seems to be different from your pictures. Where is the IBT and Transfer Belt in this picture and which screws do I need to remove to access? Thank you very much!Phaser 6510Phaser 6510

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Thank you very mucho for your support.

i cleaned everything up and the error was gone for good, theres one problem though, when i tried printing some color samples, i get these black-greenish lines on the paper, it seems to me that the IBT cleaner is not taking out the residual toner properly. After that I looked  at the black film again and it looks kind of dirty but not as dirty as the last time. Any idea on what could it be?

thank you very much.

WhatsApp Image 2020-01-15 at 17.45.29.jpeg

GabiE-Xerox

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

As I said, remove the IBT unit 

After that remove the IBT cleaner from the 4 screws

1-1.png

Next image is the cleaner blade removed from the IBT assy:

2-2.png

Clean the residual toner from the belt cleaner:

3-3.png

and from the belt

4-4.png

And finally reassemble all in reverse order.

Good luck!

Gabi

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

hi, can you tell me how to do those things?. i’ve been looking for videos on how to do it but i couldn’t find any, i think that it is because the machin is still relatively new.

thanks

PD: photos or videos will be greatly aprecciated 

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Is it normal for my printer to have this yellow-like toner lines over there?

i tried to cleaning the sensor but it didnt work. im thinking that it has something to do with those toner lanes in the picture.

is it possible that the toner containers are leaking toner?

thank you for your support.

WhatsApp Image 2019-12-19 at 09.54.43.jpeg

WhatsApp Image 2019-12-19 at 09.47.57.jpeg

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

ehong

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Hi, I’m trying to follow along with your instructions but my Phaser 6510 seems to be different from your pictures. Where is the IBT and Transfer Belt in this picture and which screws do I need to remove to access? Thank you very much!Phaser 6510Phaser 6510

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Thank you very mucho for your support.

i cleaned everything up and the error was gone for good, theres one problem though, when i tried printing some color samples, i get these black-greenish lines on the paper, it seems to me that the IBT cleaner is not taking out the residual toner properly. After that I looked  at the black film again and it looks kind of dirty but not as dirty as the last time. Any idea on what could it be?

thank you very much.

WhatsApp Image 2020-01-15 at 17.45.29.jpeg

GabiE-Xerox

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

As I said, remove the IBT unit 

After that remove the IBT cleaner from the 4 screws

1-1.png

Next image is the cleaner blade removed from the IBT assy:

2-2.png

Clean the residual toner from the belt cleaner:

3-3.png

and from the belt

4-4.png

And finally reassemble all in reverse order.

Good luck!

Gabi

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

hi, can you tell me how to do those things?. i’ve been looking for videos on how to do it but i couldn’t find any, i think that it is because the machin is still relatively new.

thanks

PD: photos or videos will be greatly aprecciated 

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Is it normal for my printer to have this yellow-like toner lines over there?

i tried to cleaning the sensor but it didnt work. im thinking that it has something to do with those toner lanes in the picture.

is it possible that the toner containers are leaking toner?

thank you for your support.

WhatsApp Image 2019-12-19 at 09.54.43.jpeg

WhatsApp Image 2019-12-19 at 09.47.57.jpeg

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Product Name: WorkCentre 6515

Operating System: Windows 10 x64

Im currently serching por the data base containing the information regarding the Error 094-325 from a XEROX Workcentre 6515.

Anyone know that is this error about? Does it have to do with the hardware or software? is it related to the toner containers?.

Any information is appreciated. 

Thank you for the support.

  • error
  • WorkCentre

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

ehong

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Hi, I’m trying to follow along with your instructions but my Phaser 6510 seems to be different from your pictures. Where is the IBT and Transfer Belt in this picture and which screws do I need to remove to access? Thank you very much!Phaser 6510Phaser 6510

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Thank you very mucho for your support.

i cleaned everything up and the error was gone for good, theres one problem though, when i tried printing some color samples, i get these black-greenish lines on the paper, it seems to me that the IBT cleaner is not taking out the residual toner properly. After that I looked  at the black film again and it looks kind of dirty but not as dirty as the last time. Any idea on what could it be?

thank you very much.

WhatsApp Image 2020-01-15 at 17.45.29.jpeg

GabiE-Xerox

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

As I said, remove the IBT unit 

After that remove the IBT cleaner from the 4 screws

1-1.png

Next image is the cleaner blade removed from the IBT assy:

2-2.png

Clean the residual toner from the belt cleaner:

3-3.png

and from the belt

4-4.png

And finally reassemble all in reverse order.

Good luck!

Gabi

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

hi, can you tell me how to do those things?. i’ve been looking for videos on how to do it but i couldn’t find any, i think that it is because the machin is still relatively new.

thanks

PD: photos or videos will be greatly aprecciated 

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Is it normal for my printer to have this yellow-like toner lines over there?

i tried to cleaning the sensor but it didnt work. im thinking that it has something to do with those toner lanes in the picture.

is it possible that the toner containers are leaking toner?

thank you for your support.

WhatsApp Image 2019-12-19 at 09.54.43.jpeg

WhatsApp Image 2019-12-19 at 09.47.57.jpeg

GodEater

  • Mark as New
  • Bookmark
  • Subscribe
  • Subscribe to RSS Feed
  • Permalink
  • Print
  • Report Inappropriate Content

Product Name: WorkCentre 6515

Operating System: Windows 10 x64

Im currently serching por the data base containing the information regarding the Error 094-325 from a XEROX Workcentre 6515.

Anyone know that is this error about? Does it have to do with the hardware or software? is it related to the toner containers?.

Any information is appreciated. 

Thank you for the support.

  • error
  • WorkCentre

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

5 Replies

  • Author Rod McGarrigle

    The main motor has failed and needs replacing, contact Xerox or your support company


    Was this post helpful?
    thumb_up
    thumb_down

  • Author phaless soko

    Thanks Rod. I was able to fix it. It also can be because of a bad drum. I replaced the Black drum and it worked. But now I have these strips coming on my prints. They seem to rotate the colors from Black, Cyan, Magenta and Yellow. I’ve run hundreds of copies and they don’t seem to go away. Any solution to that? 


    Was this post helpful?
    thumb_up
    thumb_down

  • Author Matthew Duffy

    Basic rules for troubleshooting

    Symptom appears in one color only

    Replace the color Toner Cartridge.

    Symptom appears in all four colors

    Replace one of these consumables: Imaging Unit, Fuser, Fuser Roll, Main Charge Grid, Transfer Kit

    Maintaining print quality Opens a new window


    Was this post helpful?
    thumb_up
    thumb_down

  • Author Rod McGarrigle

    You may still have an issue with the motor.

    Are you not under support, can you not contact Xerox?


    Was this post helpful?
    thumb_up
    thumb_down

  • Author Sudhakar  S

    I have wc 5019 machine. 042-325 error came, i repalced main motor but the motor does not rotate… Theni check that both 2 motor to the other wc 5019. It was run. I replaced the main PCB.. Both motor can run n that new PCB… I need why that error came fr PCB.. But that code nly fr main motor running error… Plz need that reason for that..?


    Was this post helpful?
    thumb_up
    thumb_down

Hello,

I’ve had my printer a little over 2 years and its been workign fine. Last week it started to generate an error message.

The code is 092-321 and it says remove black toner, reinsert and restart printer.

I did this,and it didn’t work. A couple of tries and it got going again.

It then happened again, so with a bit of google I found some possible issues (including through Xerox support). I checked the waste toner, one possibility,and found it was pretty full so got a replacement.

Everything started working again. Then today (I changed the waste toner yesterday) the message happens again. I have tried all the suggestions on the forums:

Turnign off and on

Tried a different toner cartridge

Taken the imaging drum out and cleaned.

The only thing I haven’t done is buy a new imaging drum (as seems an extreme fix if this isn’t the issue).

Does anyone have any ideas of what else I can try before accepting defeat and either getting a new printer or a new imaging drum.

Thanks

Lee

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

092-312 to 315, 092-657 to 660, 092-665 to 668 ATC Sensor Fault RAP

BSD-ON: BSD 9.5 Development (2 of 2)

092-312 Toner density in the developer unit as detected by the yellow ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-313 Toner density in the developer unit as detected by the magenta ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-314 Toner density in the developer unit as detected by the cyan ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-315 Toner density in the developer unit as detected by the black ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-657 Toner density in the developer unit as detected by the yellow ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-658 Toner density in the developer unit as detected by the magenta ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-659 Toner density in the developer unit as detected by the cyan ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-660 Toner density in the developer unit as detected by the black ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-665 Toner density in the developer unit as detected by the yellow ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.
092-666 Toner density in the developer unit as detected by the magenta ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.
092-667 Toner density in the developer unit as detected by the cyan ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.
092-668 Toner density in the developer unit as detected by the black ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.

Initial Actions

• Perform IQ1 to check for a blank page image quality defect.
• Enter dC125. Check for the below faults and perform the applicable procedures as necessary:

– 024-923 to 024-925 Y/M/C Toner Cartridge Empty RAP
– 093-912 Black Toner Cartridge Empty RAP

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

NOTE: When this fault occurs, toner density control, by the ATC sensor, is not performed and ICDC (pixels) based toner supply control is performed instead. If the fault remains for a long time, image density error (too dark or too light) may occur.

Perform the steps that follow:

1. Switch off, then switch on the machine, GP 10.
2. Check the wiring between the applicable ATC sensor, yellow ( P/J120), magenta ( P/J119), cyan ( P/J118), black ( P/J117) and the drive PWB ( P/J414) for an open circuit, short circuit or damage.
3. If the fault persists, replace a new cartridge CRUM (toner chip or drum chip) listed as below or install new components as necessary:

• Drum cartridge:

– Black drum cartridge, PL 90.20 Item 5.
– Yellow drum cartridge, PL 90.20 Item 8.
– Magenta drum cartridge, PL 90.20 Item 7.
– Cyan drum cartridge, PL 90.20 Item 6.

• Toner cartridge:

– Black toner cartridge, PL 90.05 Item 13.
– Yellow toner cartridge, PL 90.05 Item 10.
– Magenta toner cartridge, PL 90.05 Item 11.
– Cyan toner cartridge, PL 90.05 Item 12.

• Drive PWB, PL 1.10 Item 4.
• ESS PWB, PL 3.10 Item 6.
• HVPS, PL 1.05 Item 7.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

13 Problem Solving

13

470

Error Code

092-320

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

092-321

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

093-320

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

094-310

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

094-311

094-316

094-320

094-321

102-356

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

116-210

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

116-211

[Cause]

[Remedy] Switch off the machine power, make sure that the touch screen is

116-212

116-220

[Cause]

[Remedy] Contact our Customer Support Center.

Cause and Remedy

Density of Cyan color is low. Drum cartridge or toner cartridge

may not be set properly.

blank, and then switch on the machine power. If the same

message is displayed again, pull out the drum cartridge [R4] and

the toner cartridge [C] (cyan), and then insert them again. If the

error still is not resolved, contact our Customer Support Center.

Density of Black color is low. Drum cartridge or toner cartridge

may not be set properly.

blank, and then switch on the machine power. If the same

message is displayed again, pull out the drum cartridge [R4] and

the toner cartridge [K] (black), and then insert them again. If the

error still is not resolved, contact our Customer Support Center.

An error occurred in the machine.

blank, and then switch on the machine power. If the same

message is displayed again, contact our Customer Support

Center.

An error occurred.

blank, and then switch on the machine power. If the same

message is displayed again, contact our Customer Support

Center.

An error occurred in the machine.

blank, and then switch on the machine power. If the same

message is displayed again, contact our Customer Support

Center.

An error occurred in the USB memory device or media reader.

blank, and then switch on the machine power. If the error still is

not resolved, contact our Customer Support Center.

An error occurred in the USB memory device or media reader.

blank, and then switch on the machine power. If the error still is

not resolved, contact our Customer Support Center.

Failed to enter the Download mode.

092-312 to 315, 092-657 to 660, 092-665 to 668 ATC Sensor Fault RAP

BSD-ON: BSD 9.5 Development (2 of 2)

092-312 Toner density in the developer unit as detected by the yellow ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-313 Toner density in the developer unit as detected by the magenta ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-314 Toner density in the developer unit as detected by the cyan ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-315 Toner density in the developer unit as detected by the black ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-657 Toner density in the developer unit as detected by the yellow ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-658 Toner density in the developer unit as detected by the magenta ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-659 Toner density in the developer unit as detected by the cyan ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-660 Toner density in the developer unit as detected by the black ATC sensor abnormal. This fault occurs when the difference between the maximum and minimum values in the ATC sensor measurement set is lower than the threshold value.
092-665 Toner density in the developer unit as detected by the yellow ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.
092-666 Toner density in the developer unit as detected by the magenta ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.
092-667 Toner density in the developer unit as detected by the cyan ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.
092-668 Toner density in the developer unit as detected by the black ATC sensor abnormal. This fault occurs when the average value of the ATC sensor measurement values is not between the upper and lower limit values.

Initial Actions

• Perform IQ1 to check for a blank page image quality defect.
• Enter dC125. Check for the below faults and perform the applicable procedures as necessary:

– 024-923 to 024-925 Y/M/C Toner Cartridge Empty RAP
– 093-912 Black Toner Cartridge Empty RAP

Procedure

WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

NOTE: When this fault occurs, toner density control, by the ATC sensor, is not performed and ICDC (pixels) based toner supply control is performed instead. If the fault remains for a long time, image density error (too dark or too light) may occur.

Perform the steps that follow:

1. Switch off, then switch on the machine, GP 10.
2. Check the wiring between the applicable ATC sensor, yellow ( P/J120), magenta ( P/J119), cyan ( P/J118), black ( P/J117) and the drive PWB ( P/J414) for an open circuit, short circuit or damage.
3. If the fault persists, replace a new cartridge CRUM (toner chip or drum chip) listed as below or install new components as necessary:

• Drum cartridge:

– Black drum cartridge, PL 90.20 Item 5.
– Yellow drum cartridge, PL 90.20 Item 8.
– Magenta drum cartridge, PL 90.20 Item 7.
– Cyan drum cartridge, PL 90.20 Item 6.

• Toner cartridge:

– Black toner cartridge, PL 90.05 Item 13.
– Yellow toner cartridge, PL 90.05 Item 10.
– Magenta toner cartridge, PL 90.05 Item 11.
– Cyan toner cartridge, PL 90.05 Item 12.

• Drive PWB, PL 1.10 Item 4.
• ESS PWB, PL 3.10 Item 6.
• HVPS, PL 1.05 Item 7.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

• 106R03733 106R03736 106R03735 106R03734

Drum Chip:

• 113R00780 113R00782

Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.

Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.

Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.

Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:

  • Коды ошибок Xerox 1012, 1012(RE)
  • Коды ошибок Xerox 1020
  • Коды ошибок Xerox 1025
  • Коды ошибок Xerox 1035
  • Коды ошибок Xerox 1038
  • Коды ошибок Xerox 2830
  • Коды ошибок Xerox 5011, 5012, 5014
  • Коды ошибок Xerox 5016, 5017, 5316, 5317
  • Коды ошибок Xerox 5018, 5028
  • Коды ошибок Xerox 5312, 5313, 5314
  • Коды ошибок Xerox 5318, 5320, 5322
  • Коды ошибок Xerox 5328
  • Коды ошибок Xerox 5330
  • Коды ошибок Xerox 5340, 5343
  • Коды ошибок Xerox 5345
  • Коды ошибок Xerox 5350, 5352
  • Коды ошибок Xerox 5355
  • Коды ошибок Xerox 5622
  • Коды ошибок Xerox XC520, 540, 560, 580

Xerox 1012, 1012(RE)

Код ошибки Описание
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem
E1 Jam between paper feed and fuser
E3 Jam in fuser
E5 Clam shell open
E6 Paper feed section cover is open
J1 Toner cartridge near empty
J3 Drum cartridge not seated properly
J7 Waste toner full (replace drum cartridge)
L6 Key counter out
L8 Exposure area overheat
U1 No clock pulse (drive problem)
U2 Scan problem
U3 Lens/mirror problem (RE model only)
U4 Heat problem
U8 Exposure lamp control circuit problem

Xerox 1020

Код ошибки Описание
LL Probable bad heater lamp

Xerox 1025

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 1035

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 1038

Код ошибки Описание
A1 DF jam
C1 PF jam cass. 1
C2 PF jam cass. 2
C3 PF jam cass. 3
C9 Bypass jam
E1-1 Paper jam before exit switch
E1-2 Paper jam
E1-5 Paper jam
E1-6 Paper jam
E3-3 Paper jam at exit switch
E3-4 Paper jam at exit switch
E5 Front door open
F1 Collator jam
F5 Collator interlock
F8 No power to collator
F9 Collator bin home switch
J7 250 copies since toner waste was full
L5 Original cass. not present after clearing interrupt
L6 Key counter
L8 Platen glass too hot
U1 Main motor clock pulse
U2 Scan problem
U3-1 Lens problem
U4-1 Open thermistor
U4-2 Low temperature
U4-4 Temperature
U4-5 Main PWB
U6-1 Main PWB
U6-2 Main PWB
U6-3 Main board battery
U6-4 Initialization
U8 Exposure lamp

Xerox 2830

Код ошибки Описание
A9 Scanner location
C1 Paper feed — upper cassette
C2 Paper feed — lower cassette
C9 Bypass jam
E5 Clam shell is open
E5 Clam shell open
L6 Key counter
U1 Off/On
U2 Optics
U4 Low fuser temperature

Xerox 5011, 5012, 5014

Код ошибки Описание
C8 Bypass jam/no paper
C9 Bypass jam
E1 Jam
E3 Fuser jam
E5 Clamshell open
E6 PF section cover open
J1 Toner cartridge amost empty
J3 Copy cart (drum unit) missing/not seated right
J7 Copy cartridge has run 18,000 copies
J8 Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew
L6 Key counter
L8 Exposure glass too hot
U1 Drive problem
U2 Scan problem
U3 Lens or mirror drive problem
U4 Fuser problem. Heat lamp, thermoswitch, SSR, thermistor
U6 Battery on main board
U8 Exposure lamp or exposure lamp circuit

Xerox 5016, 5017, 5316, 5317

Code Description
A1-1 Document feeder feed jam
A1-2 Document feeder belt jam
A2-1 Document feeder exit jam
A2-2 Duplex jam
A3 DAD interlock
A5 Duplex and DAD right side interlock
A6 Copier jams after
A9 Document feed belt drive motor
C1-3 Top cassette misfeed
C2-3 Middle cassette misfeed
C3-3 Bottom cassette misfeed
C9-3 Bypass misfeed
E1-11 to E1-14 Paper jam in machine. Did not reach exit switch soon enough
E1-6 Paper path jam
E3-31 to E3-34 Exit switch jam
E3-6 Fuser jam
E5 Front door interlock
E6 Right side interlock or TTM interlock
F1 Sorter jam
F5 Sorter interlock
F8 Sorter board to copier main board communication problem
F9 Sorter bins

Xerox 5018, 5028

Code Description
A1 Document is ADF
A1-8 Main board received reset signal
A2 ADF jams
A6, A7 ADF jams
A9 ADF jams
C1 — C4 Feed jam
C5-1 to C5-4 Jams in various areas
C5-2 Jams in various areas
C5-3 Jams in various areas
C5-4 Duplex jam
E0 Machine has reset
E1 Jam
E1-E0 Registration jam
E1-E5 Clamshell interlock
E1-E6 Right side interlock
E1-E7 Two tray interlock
E1-E8 Sorter interlock
E1-E9 Copy cartridge interlock
E2 Reset signal happened
E3 Jam
E4 Exit jam
E4-10 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock. Duplex interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E7 Duplex interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
J1-1 Add toner
J1-2 Temporary low toner signal
J2-0 Replace copy cartridge
L2 2000 copies left on copy cartridge
L3 ADF to machine communication problem
L4 (flashing) 1000 copies left on fuser web
rr Bad EPROM on main board
U0 Main board
U2 Scan problem
U2-1 Scan home
U3-00 Cam drive problem
U3-01 Cam movement slow
U3-04 Main board to duplex communication
U3-09 Cam problem
U3-12 Jogger problem
U3-19 Cam problem
U3-21 Cam problem
U3-23 Cam problem
U3-29 Cam problem
U3-32 Cam problem
U3-34 Cam problem
U3-39 Cam problem
U3-43 Cam problem
U3-45 Cam problem
U3-49 Cam problem
U3-54 Cam problem
U3-56 Cam problem
U3-59 Cam problem
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm up

Xerox 5312, 5313, 5314

Код ошибки Описание
C1 Upper paper feed problem. Did not reach feed sensor
C2 Lower paper feed problem. Did not reach feed sensor
E1 Exit jam. Paper did not reach exit sensor
E3 Exit jam. Paper still on exit sensor
J1 Add toner
J3 Copy cartridge (drum unit) not installed
J7 Copy cartridge (drum unit) must be replaced
J8 Copy cartridge (drum unit) problem
L6 Problem with an accessory. Installed but not initialized
U1 Drive problem. Main motor, gear etc.
U2 Scan problem
U3 Main board dip switches wrong. Lens drive problem
U4 Fuser problem. Heat lamp, thermal switch, overheat, thermistor.
U6 EPROM error
U8 Auto exposure sensor. No exposure lamp or weak lamp

Xerox 5318, 5320, 5322

Code Description
A1-11 Original ready switch
A1-12 Feed sensor
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A1-21 Original ready switch and document registration sensor or both the document feed sensor and document registration sensor
A1-22 ADF registration sensor
A1-23 Original did not reach ADF registration sensor quickly enough
A1-24 ADF sensor stuck down too long
A1-25 ADF sensor actuated at the wrong time during single sheet feed
A1-26 ADF sensor not actuated quickly enough in sheet feed mode
A1-31 In reverse, ADF sensor is not actuated soon enough
A1-32 In reverse, ADF sensor is actuated too long
A2 ADF exit problems
A2-1 Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated
A2-2 ADF exit switch
A2-3 ADF exit switch is not actuated on time
A3 Irregular size documents
A3-1 Wrong size original sensed in 1:1 mode
A3-2 Wrong size original sensed in the 2:1 mode
A5 ADF interlock
A5 ADF interlock
A6 ADF single sheet document reset.
A6-1 Reset original
A6-2 Reset sheet feeder
A7 Document cover interlock
A8 ADF exit interlock
C1 Tray 1 jam
C1-2 Paper feed problem in tray 1
C1-3 Paper does not reach registration
C2 Tray 2 jam
C3 Tray 3 jam
C3-1 Paper feed problem from tray 3
C3-2 Paper feed problem from tray 3
C3-3 Paper feed problem from tray 1
C6-1 Duplex paper feed problem
C6-2 Duplex and/or tray 1 paper feed problem
C6-3 Paper feed problem from tray 1
C7-1 Paper feed problem from HCF
C7-2 Paper feed problem from HCF on tray 1
C7-3 Paper feed problem from tray 1
C8 Paper stays in tray or duplex or HCF
C8-1 Paper on tray 1 feed sensor
C8-2 Paper on tray 2 feed sensor
C8-3 Paper on tray 3 feed sensor
C8-4 Paper on HCF feed sensor
C8-5 Paper in duplex section
C9 Bypass feed problem
C9-3 Paper from bypass did not reach registration sensor quickly enough
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-30 to E3-35 Exit switch actuated too long
E3-6 Exit jam
E3-6 Paper on exit switch
E4-10 to E4-14 Inverter sensor not actuated.
E4-10 to E4-45 Paper did not reach inverter switch soon enough
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Paper on inverter switch
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2 Duplex inverter interlock
E7-3 Duplex interlock
E8-10 to E8-15 Paper on duplex feed sensor is not actuated soon enough
E8-6 Paper in duplex
E8-6 to E8-15 Duplex entry sensor
F1-1 Paper did not reach sorter
F1-2 Paper stayed on sorter feed sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
H2-1 Communication problem between main board and duplex board
H2-2 Side guard sensor problem
H3-1 Communication problem between main board and HCF
H3-2 Upper limit sensor problem on HCF
H6-1 ADF size sensor
H6-2 ADF nudgeer sensor
H6-3 Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner
J1 Black toner is empty, but 100 copies have been run without changing toner
J3 Replace copy cartridge
J3 No copy cartridge (drum unit)
J7 Copy cartrige must be replaced
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM must be changed
L6 Auditron or other counter problem
L6 Key counter not installed
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 Scan home problem
U2-1 to U2-4 Scan home sensor
U2-2 Scan home problem or optics problem
U2-3, U2-4 Scan home problem
U3-1 Lens sensor problem
U4-1 Fuser thermistor open
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 Exposure lamp problem
U8-2 Communication problem main board and exposure board
U8-3 Exposure lamp or exposure lamp board problem
U8-4 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5328

Code Description
A1 Document in ADF
A1-8 Main board received reset signal
A2 ADF jams
A6 ADF registration jam
A7 ADF interlock
A9 Tray 1 jam
C1 Tray 2 jam
C2 Tray 3 jam
C3 Bypass feed jams
C4 Machine has reset
E1 Jam
E1-5 Clamshell interlock
E1-6 Right side interlock
E1-7 Two tray interlock, or duplex interlock
E1-8 Sorter interlock
E1-9 Copy cartridge interlock
E1 or E1-0 Registration jam
E2 Reset signal happened
E3 Jam in transfer area
E4 Exit jam
E4-0 Exit jam
E4-5 Clamshell interlock
E4-6 Right side interlock
E4-7 Two tray interlock
E4-8 Sorter interlock
E4-9 Copy cartridge interlock
E5 Clamshell interlock
E6 Right side interlock
E9 Copy cartridge interlock
F3-1 Sorter bin home switch
F3-2 Sorter cam switch
F3-3 Sorter cam switch
F5 Sorter interlock
J1-1 Add toner
J1-2 Temporary low toner signal
J2-1, J2-2 Replace copy cartridge
J5, J6 ADF to machine communications problem
L2 2000 copies left on cartridge
L3 ADF to machine communications problem
L4 (flashing) 1000 copier left on fuser web
L6 Auditron or other counter problem
LL Main board. Try simulation 1.1 to initialize
rc Wrong operation panel installed
rr Bad EPROM on main board. Try 1.1
U0 Main board
U2 Scan problem
U2-1 Scan home
U2-2 Scan home or scan encoder
U2-4 Scan home or scan dual page sensor
U2-7 Scan home
U4-1 Fuser problem. Long warm up
U4-2 Low fuser temperature after warm up
U4-3 High fuser temperature
U4-4 Open fuser thermistor
U4-6 Replace fuser web.
U4-7 Thermistor signal problem
U7-1 Copy cartridge belt drive problem
U9-3 Exposure lamp problem
U9-4 Toner motor
U9-5 Problem in warm-up

Xerox 5330

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF.
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset.
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else.
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated.
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3 Sorter bin home switch
U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board

Xerox 5340, 5343

Code Description
00-009; 030 to 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 03-336 LLM communications problems with edit
03-340 NVM memory
03-341, 03-347 Communications problems between IOT and sorter
03-350, 03-354 Communications problem with LLM and user interface
03-363, 03-364 Communications problem between LLM & optics
03-370, 03-373 Communications problem between LLM & DADF
03-380, 384  
03-416, 03-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443, 03-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100, 05-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300, 06-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344, 06-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360, 07-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100, 08-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115, 08-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310, 08-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100, 11-116 Sorter jam
11-150, 11-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A, B, C, D, E, F, G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A, B, C, D, E Sorter auto stapler bin
11-370, 371, 372A, 373A, 373B, 374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A, 385B, 390A,B,C,D,E, 396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5345

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 RDH interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox 5350, 5352

Code Description
00-009, 030, 031, 032, 033 A door was opened while paper was being fed
00-047 Paper in duplex
00-1 Auditron
00-2 Diagnostic error
00-3 Faults error
00-4 Ric error
00-5 Job manager system error
00-6 LLM interface
00-7 Standby error
00-8 Communications error
00-9 Xerographic error
01-300 Front interlock
01-310 Right upper interlock
01-315 Left upper interlock
01-320 Left lower interlock
01-325 Fuser interlock
02-910 Key counter missing
02-920 Wrong combination of accessories
03-321, 322, 326, 327 LLM to ISIL communications problems
03-328 IOT communications problem with duplex or tray 4
03-330 IOT communications problems with HCF
03-335, 336 LLM communications problems with edit
03-340 NVM memory
03-341-347 Communications problems between IOT and sorter
03-350-354 Communications problem with LLM and user interface
03-363, 364 Communications problem between LLM & optics
03-370-03-373 Communications problem between LLM & DADF
03-380, 384  
03-416-422 RAM memory problem
03-424, 426 NVM memory problem
03-430, 432 Billing problem
03-439 GRAIB communications problem
03-440 RIC communications problem
03-441 RIC NVM problem
03-442 Modem
03-443-458 RIC problems
03-460 Serial communications processor problem
04-300 Main motor or drive problem
05-100-108 DADF registration sensor
05-110 DADF exit sensor
05-115, 120 DADF jams
05-305 DADF document drive
05-310, 312 DADF document sensor
05-316 DADF registration sensor jam
05-325 DADF exit sensor
05-335, 341, 345 DADF interlock switches
06-300-310 Scan problems
06-315 Scan drive
06-320A, 320B, 320C, 325 Scan problem
06-330 Lens drive
06-340 Exposure control problem
06-342 LLM CPU problem
06-344-350 Exposure cvontrol problem
06-352 IOT CPU problem
07-300, 315, 330, 345 Tray faults
07-360-370 HCF problems
07-375, 380A, 380B Duplex problems
08-100-110 Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1
08-115-162 Feed problem. Lead edge of copy paper is late getting to registration sensor
08-165 Paper jam at registration sensor
08-310-370 Paper at a sensor when power is turned on
08-330 DADF nudger sensor
08-380 Registration side to side problem with home position
08-390 Nip
09-300 Copy cartridge finished (drum unit)
09-310 Add black toner Add color toner
09-320 Add color toner
09-330 Wrong copy cartridge (wrong drum unit)
09-340 Drum cartridge not installed properly
09-350 Waste toner full
100 A fault has occurred
10-100 Exit jam
10-105 Exit jam
10-110 Vertical sensor jam
10-120, 122, 125 Duplex jam
10-150, 155 Too much or not enough paper in duplex tray
10-300 Fuser thermistor
10-302 Low fuser temperature
10-304 Bad fuser temp
10-308 High fuser temperature or open thermistor
10-310 High fuser temperature
10-312 Fuser not up to temperature after energy save
10-314 Fuser problem
10-320 Fuser web finished
10-330, 335, 340 Exit switch, vertical sensor switch actuated when power is turned on
11-100-116 Sorter jam
11-150-176 Sorter auto stapler jam
11-310, 314, 316 Sorter interlock
11-325A,B,C,D,E,F,G Sorter index
11-352, 354, 356 Sorter auto stapler interlocks
11-365A,B,C,D,E Sorter auto stapler bin
11-370,371,372A,373A,373B,374 Sorter auto stapler staple failure, staple home problem or tamper home problem
11-385A,385B,390A,B,C,D,E,396A Sorter auto stapler staple failure, staple home problem or tamper home problem
301 Fuser web must be replaced
302 Copy cartridge (drum unit) must be replaced
501 Tray 1 must be rebuilt
502 Tray 2 must be rebuilt
503 Tray 3 must be rebuilt
504 Tray 4 must be rebuilt
505 HCF must be rebuilt
506 Bypass must be rebuilt
507 Duplex unit must be rebuilt
508 Replace black developer
509 Replace red developer
510 Replace green developer
512 Replace brown developer
513 Copy cartridge (drum unit) will need replacing soon
514 Fuser web will need replacing soon
515 DADF belt should be replaced
516 DADF feed rollers should be replaced
517 Replace exposure lamp
518 Replace suction filter
519 Replace ozone filter
520 Replace optics filter
521 Replace particle filter
522 Replace upper fuser roller
523 Replace fuser pawls
524 Replace pressure roller
525 Replace pressure roller pawls
900-905 Key operator calls

Xerox 5355

Код ошибки Описание
01-01 Frequency monitoring and zero cross problem
01-02 Interlock
01-03 AC power problem
01-04 Finisher interlock
01-05 24v problem
03-01 Optics to main board communication problem
03-02 Software reset problem
03-03 Could be punched holes in the lead edge of the original
03-04 Software problem
03-06 Low battery
03-07 NVM not initialized or is missing or defective
03-17 Communication problem between main board and finisher board
03-18 Initializes one NVM counter to agree to others
03-19 All three NVM counter to agree with others
03-20 Main board/interface board problems
03-21 Problem with RIC NVM
03-22 RIC modem problem
03-23 RIC real time clock failure.
03-25 RIC NVM problem or not initialized
03-27 NVM problem
03-28 Watchdog software problem
03-29 Microprocessor crystal not at correct frequency
03-30 No software response from finisher after 20 seconds have elapsed
06-01 Lens did not reach 1.1 position
06-02 1/2 rate scanner problem
06-03 Scan home problem
06-04 Scan home problem
06-05 Scan home problem
06-06 Scan encoder
06-07 Scan encoder
06-08 Scan drive boost
06-09 Scan encoder
06-11 Scan encoder pulse phases
06-12 Insufficient scan damping
07-01 Duplex tray not home during duplexing
07-02 Tray 2 not home when selected
07-13 Tray 2 height sensor problem
07-15 Tray 2 empty
07-16 Tray 1 door open
07-18 Tray 1 stack sensor
07-22 Tray 1 empty
07-26 Tray 1 bypass switch actuated too long
07-27 Tray 1 bypass switch deactuated too early
07-30 Paper in duplex
07-31 Paper in duplex
07-32 Duplex tray empty, when paper should be there
08-10 Paper did not reach tray 2 input tray sensor
08-11 Paper did not reach duplex input sensor
08-12 Paper did not reach tray 1
08-14 Paper did not leave tray 2 input sensor quickly enough
08-18 Trail edge did not reach tray 2 input sensor quickly enough
08-19 Trail edge did not reach tray 1 input sensor quickly enough
08-20 Paper in duplex
08-21 Paper in tray 2 input
08-22 Paper in tray 2 or duplex at wrong time
08-23 Paper at tray 1 input at wrong time
08-24 Paper in tray 1 at wrong time
08-28 Upper and lower nips problem
09-08 Low toner condition
09-12 Drum signals are out of range
09-13 Unstable drum patch readings
09-15 Patch is too dark
09-16 Patch is too light
09-17 Open toner container access cover
09-18 Low toner level
09-21 Low toner sensor disconnected
09-22 Low toner condition, even after machine has been theoretically, adding toner
10-02 Low fuser temperature
10-03 High fuser temperature
10-06 Paper did not reach out put switch
10-07 Paper stayed on output switch
10-10 Paper did not reach decurler sensor
10-11 Paper did not reach decurler sensor
10-12 Paper on decurler sensor
10-13 Paper did not reach duplex entry sensor in time
10-14 Paper did not reach duplex entry sensor in time
10-15 Paper on entry sensor at wrong time
10-17 Fuser temperature is too high and fuser relay has deactuated
12-01 Paper at finisher input sensor
12-02 Paper did not reach finisher
12-03 Paper reached finisher too soon
12-05 Paper at stapler
12-06 Paper at stapler
12-07 Paper did not reach stapler
12-08 Paper did not reach stapler
12-10 Complied motor not working properly
12-15 Eject motor problem and/or eject encoder
12-20 Stacker motor problem
12-21 Stacker interlock
12-22 Stacker bottom sensor
12-23 Stacker bottom sensor
12-24 Stacker bottom sensor senses full
12-25 Stack height sensor
12-26 Stack height sensor
12-27 Stack height sensor
12-30 Offset home sensor
12-31 Offset home sensor
12-32 OCT switch
12-35 Eject nip carriage
12-36 Eject cam interlock
12-37 Eject nip carriage open timing
12-38 Eject cam interlock
12-40 Tamper motor
12-41 Tamper home problem
12-42 Tamper home sensor
12-43 Staple load sensor
12-44 Tamper home sensor
12-45 Tamper home sensor
12-50 Low on staples
12-51 Stapler home sensor
12-52 Stapler home sensor
12-53 Eject cam interlock
33-37 Too few documents
55-01 rdh interlock switch open during use
55-04 Paper on bypass sensor
55-05 Paper at vacuum timing sensor
55-06 Paper on output sensor
55-10 No paper reached S31
55-20 Paper did not leave S31 at correct time
55-24 Set counter arm problem
55-25 Documents in input tray not detected
55-27 Lead edge did not reach S35 at correct time
55-2955-30 Trail edge did not reach S35 at correct time
55-31 S32, ADF registration sensor did not see paper at correct time
55-32 S32 did not see trail edge at correct time
55-33 S36 One too many documents
55-36 One too many documents
55-39 Hole count problem on document feeder belt
55-40 Document belt travel problem
55-41 Document belt mistracking or skewing
55-45 Paper at inverter sensor
55-47 Inverter sensor did not see paper lead edge at correct time
55-49 More than 50 sheets in input tray
55-50 Right side interlock
55-51 Left side interlock
55-55 Document on glass
93-93 NVM has to be initialized after new software installed

Xerox XC520, 540, 560, 580

Код ошибки Описание
H2 Fuser thermistor
H3 Fuser temperature too high. Must be reset in diagnostics
H4 Fuser temperature too low. Must be reset in diagnostics
L3 Scan problem
L4 Min motor drive problem
L8 Exposure lamp not lightning or not enough light reaching auto exposure sensor
P Paper did not feed

Xerox 5622

Code Description
A1-1 to A1-32 All indicate a paper path problem, etc. in the ADF
A2 ADF exit problems
A3 Irregular size documents
A5 ADF interlock
A6 ADF single sheet document reset
A7 Platen interlock
A8 ADF exit interlock
C1 Tray 1 jam
C2 Tray 2 jam
C3 Tray 3 jam
C6-1, C6-2 Jams related to duplex
C6-3 Registration sensor, re tray 1
C7-1, C7-2 HCF feed problems
C7-3 Tray 1 feed problem
C8 Paper stays in tray or duplex or HCF
C9 Bypass feed problem
E1-10 to E1-25 Internal jam
E1-6 Paper on registration sensor
E2 Reset signal happened. Might read E-2 something else
E3-30 to E4-14 Exit jam
E3-6 Exit jam
E4-10 to E4-14 Inverter sensor not actuated
E4-15 Inverter sensor
E4-40 to E4-45 Duplex entry sensor
E4-6 Inverter sensor
E5 Front door interlock
E6-1 Tray 1 interlock
E6-2 2 tray or duplex interlock
E6-3 HCF interlock
E7-2, E7-3 Duplex interlock
E8-6 to E8-15 Duplex entry sensor
F1-1 Sorter entry sensor
F1-6 Sorter exit sensor
F3 Paper size not available for sort/stack
F5 Sorter interlock
J1 Add toner
J3 Replace copy cartridge
J7 Replace copy cartridge
J8-1 Wrong copy cartridge installed
J8-2 Copy cartridge EEPROM
L6 Auditron or other counter problem
L8 Platen glass temperature is too high
L9 Communication problem between interimage erase/edge lamps and main board
U1-1 Main motor drive problem
U2-1 to U2-4 Scan home sensor
U3-1 Lens sensor
U4-1 Open fuser thermistor
U4-2 Fuser did not warm up properly
U4-3 Fuser temperature too high
U4-4 Fuser problem. Staying on too long
U4-6 High fuser temperature
U5-1 Sorter bin home switch not activated
U5-2 Sorter bin home switch stayed actuated
U5-3, U5-4 Sorter bin home switch
U6-1 ROM problem
U6-2 RAM problem
U6-3 Low battery
U6-4 Incorrect value in NVM. Reinitialize main board with code 20-96
U8-1 to U8-6 Problem with exposure lamp, lamp sensor, lamp board
 

     Во время работы с аппаратом могут возникать проблемы, связанные с неисправностями «железа» или ПО. И если расходные материалы можно просто заменить, то с «мозгами» нужно разбираться. Поэтому, для экономии времени и удобства, ниже представлены возможные коды ошибок (FAULT ERROR CODE), которые показывают Xerox DocuColor DC 240/250/242/252/260 и WorkCentre WC 7655/7665/7675/7755/7765/7775 при неисправности, и их значение:

коды ошибок (fault code/error) продолжение. Часть 2

     …

 061-323 ERROR — RAP No SOS Failure.

 061-324 ERROR — RAP No SOS Failure.

 061-325 ERROR — RAP No SOS Failure.

 061-326 ERROR — RAP ROS Connect Failure Yellow.

 061-327 ERROR — RAP ROS Connect Failure.

 061-328 ERROR — RAP ROS Connect Failure.

 061-329 ERROR — RAP ROS Connect Failure Black.

 061-334 ERROR — RAP ROS Y/M VDD Failure.

 061-335 ERROR — RAP ROS C/K VDD Failure.

 061-336 ERROR — RAP ROS Y/M VDD Down Failure.

 061-337 ERROR — RAP ROS C/K VDD Down Failure.

 061-338 ERROR — RAP SOS Stop Magenta Failure.

 061-339 ERROR — RAP SOS Stop Black Failure.

 061-340 ERROR — RAP ROS LD Failure Black.

 061-341 ERROR — RAP ROS LD Failure Yellow.

 061-342 ERROR — RAP ROS LD Failure Magenta.

 061-343 ERROR — RAP ROS LD Failure Cyan.

 061-600 ERROR — RAP ROS Data Failure Yellow.

 061-601 ERROR — RAP ROS Data Failure Magenta.

 061-602 ERROR — RAP ROS Data Failure Cyan.

 061-603 ERROR — RAP ROS Data Failure Black.

 061-604 ERROR — RAP LD Alarm Yellow.

 061-605 ERROR — RAP LD Alarm Magenta.

 061-606 ERROR — RAP LD Alarm Cyan.

 061-607 ERROR — RAP LD Alarm Black.

 062-210 ERROR — RAP IISS Hot Line Failure.

 062-211 ERROR — RAP IIT/IPS EEPROM Failure (IPS).

 062-220 ERROR — RAP IPS-EXT Connection Failure.

 062-277 ERROR — RAP IIT/IPS-DADF Communication Failure.

 062-278 ERROR — RAP IIT-Extension Communication Failure.

 062-300 ERROR — RAP Platen Interlock Open.

 062-310 ERROR — RAP IIT/IPS-ESS Communication Failure.

 062-311 ERROR — RAP IIT Software Logic Failure.

 062-321 ERROR — RAP IPS-YATA Connection Failure.

 062-322 ERROR — RAP EXT-YATA Connection Failure.

 062-323 ERROR — RAP YATA PWBA Failure.

 062-345 ERROR — RAP IIT/IPS EEPROM Failure (IIT).

 062-355 ERROR — RAP IPS Fan Failure.

 062-356 ERROR — RAP Lamp Fan Failure.

 062-357 ERROR — RAP CCD Fan Failure. An error signal was detected for the CCD fan.

 062-360 ERROR — RAP Carriage Position Failure.

 062-362 ERROR — RAP X Hard Failure.

 062-371 ERROR — RAP Lamp Failure.

 062-380 ERROR — RAP Platen AOC Failure.

 062-386 ERROR — RAP Platen AOC Failure.

 062-389 ERROR — RAP Carriage Over Run (Scan End).

 062-392 ERROR — RAP IT/IPS Memory Failure.

 062-393 ERROR — RAP IIT/IPS PWB Failure.

 062-790 ERROR — RAP X Detect Failure.

 063-210 ERROR — RAP Extension EEPROM Failure.

 063-220 ERROR — RAP IPS-EXT Psync Failure.

 063-230 ERROR — RAP EXT Image Parameter Failure.

 063-240 ERROR — RAP EXT Image Parameter Failure.

 065-210 ERROR — RAP Extension Page Memory Failure 1.

 065-211 ERROR — RAP CIS Shading FROM Failure

 065-212 ERROR — RAP CIS Shading Level Failure.

 065-213 ERROR — RAP CIS Output Level Failure.

 065-215 ERROR — RAP Extension Page Memory Failure 2.

 065-216 ERROR — RAP Extension Page Memory Failure 3.

 065-219 ERROR — RAP CIS Black White Level Failure.

 065-220 ERROR — RAP 1P DUP PWB-EXT Psync Failure.

 071-101 ERROR — RAP Feed Out Sensor 1 is not turned ON.

 071-104 ERROR — RAP Pre Registration Sensor ON Jam (Tray 1).

 071-105 ERROR — RAP Registration Sensor ON Jam (Tray 1).

 071-210 ERROR — RAP Tray 1 Lift Up Failure.

 072-101 ERROR — RAP Tray 2 Miss Feed Jam.

 072-102 ERROR — RAP The Tray 1 Feed Out Sensor does not turn ON.

 072-104 ERROR — RAP Pre-Registration Sensor ON Jam (Tray 2).

 072-105 ERROR — RAP Registration Sensor ON Jam (Tray 2).

 072-210 ERROR — RAP Tray 2 Lift Up Failure.

 073-101 ERROR — RAP Tray 3 Miss Feed Jam.

 073-102 ERROR — RAP Feed Out Sensor 1 ON Jam (Tray 3).

 073-104 ERROR — RAP Pre Registration Sensor ON Jam (Tray 3).

 073-105 ERROR — RAP Registration Sensor ON Jam (Tray 3).

 073-210 ERROR — RAP Tray 3 Lift Up Failure.

 074-101 ERROR — RAP Pre Feed Sensor 4 is not ON within the specified time after the start of feed from Tray 4.

 074-102 ERROR — RAP Feed Out Sensor 1 ON Jam (Tray 4).

 074-103 ERROR — RAP The Tray 4 Feed Out Sensor is not ON within the specified time for paper fed from Tray 4.

 074-104 ERROR — RAP Pre Registration Sensor ON Jam (Tray 4).

 074-105 ERROR — RAP Registration Sensor ON Jam (Tray 4).

 074-210 ERROR — RAP Tray 4 Lift Up Failure.

 075-100 ERROR — RAP Tray 5/Bypass Pre Feed Sensor is not ON within the specified time after the start of feed from Tray 5.

 075-101 ERROR — RAP Tray 5/Bypass Feed Out Sensor is not ON within the specified time for paper fed from Tray 5.

 075-109 ERROR — RAP Paper from Tray 5/Bypass does not turn ON Pre Regi Sensor within a specified time.

 075-135 ERROR — RAP Paper from Tray 5/Bypass does not turn ON Regi Sensor within a specified time.

 075-210 ERROR — RAP Tray 5/Bypass Lift Up Sensor does not turn ON within a specified time after Tray 5 begins to lift.

 075-211 ERROR — RAP Tray 5/Bypass Lift Down Sensor does not turn ON within a specified time after Tray 5 begins to lower.

 077-102 ERROR — RAP Paper from Tray 2 did not turn on the Transport Path Sensor 1 within the specified time.

 077-103 ERROR — RAP The Fuser Exit Sensor did not turn off within the specified time in straight exit mode.

 077-106 ERROR — RAP The Fuser Exit Sensor did not come on within the specified time after the Registration Motor.

 077-107 ERROR — RAP The Fuser Exit Sensor did not turn off within the specified time in invert exit mode.

 077-109 ERROR — RAP The IOT Exit Sensor did not come on at the specified time in non-invert mode.

 077-111 ERROR — RAP The IOT Exit Sensor did not come on within the specified time in invert exit mode.

 077-113 ERROR — RAP The IOT Exit Sensor did not turn off at the specified time in non-invert mode.

 077-115 ERROR — RAP The IOT Exit Sensor did not turn off within the specified time in invert exit mode.

 077-118 ERROR — RAP Paper from Duplex did not turn on the Pre Regi Sensor within the specified time.

 077-120 ERROR — RAP Post 2nd BTR Sensor On JAM.

 077-123 ERROR — RAP Duplex In Sensor does not turn ON a spec time after the start of invert.

 077-129 ERROR — RAP Paper from Duplex did not turn on the Regi Sensor within the specified time.

 077-130 ERROR — RAP Duplex Out Sensor does not turn ON witin a specified time after Duplex In Sensor turns ON.

 077-300 ERROR — RAP The Front Cover is open.

 077-301 ERROR — RAP The Left Hand Interlock is open.

 077-302 ERROR — RAP The Right Hand Cover Interlock is open.

 077-303 ERROR — RAP PH Drawer Interlock Open.

 077-304 ERROR — RAP The Tray 5/Bypass Cover Interlock is open.

 077-312 ERROR — RAP Feeder Communication Failure.

 077-909 ERROR — RAP One of the IOT sensors detected paper when power was turned on or when an interlock was closed.

 077-967 ERROR — RAP The specified paper type and the paper type being used are different.

 077-968 ERROR — RAP The type of paper in the tray was changed.

 078-100 ERROR — RAP Paper from Tray 6 does not turn ON Pre Regi Sensor within a specified time.

 078-101 ERROR — RAP The Tray 6 Feed Out sensor is not ON within the specified time for paper fed from Tray 6.

 078-102 ERROR — RAP Paper from Tray 6 does not turn ON the Regi Sensor within a specified time.

 078-151 ERROR — RAP The Tray 6 Feed Out Sensor did not come on within the specified time after the start of feed.

 078-250 ERROR — RAP HCF Tray #2 Lift Up Fail.

 078-300 ERROR — RAP The HCF transport interlock is open.

 078-301 ERROR — RAP HCF Side Out Interlock Open.

 089-600 ERROR — RAP Incorrect Fast Scan positioning for the reference color Cyan was detected during fine adjustment.

 089-601 ERROR — RAP The Inner MOB Sensor failed to detect the fine-adjustment patterns properly during fine adjustment.

 089-602 ERROR — RAP The CENTER MOB Sensor failed to detect the fine-adjustment patterns properly during fine adjustment.

 089-603 ERROR — RAP The OUTER MOB Sensor failed to detect the fine-adjustment patterns properly during fine adjustment.

 089-604 ERROR — RAP The INNER MOB Sensor failed to detect the rough-adjustment patterns properly during Yellow rough adjustment.

 089-605 ERROR — RAP The CENTER MOB Sensor failed to detect the rough-adjustment patterns properly during Yellow rough adjustment.

 089-606 ERROR — RAP The OUTER MOB Sensor failed to detect the rough-adjustment patterns properly during Yellow rough adjustment.

 089-607 ERROR — RAP The INNER MOB Sensor failed to detect the rough-adjustment patterns correctly during Magenta rough adjustment.

 089-608 ERROR — RAP The CENTER MOB Sensor failed to detect the rough-adjustment patterns properly during Magenta rough adjustment.

 089-609 ERROR — RAP The OUTER MOB Sensor failed to detect the rough-adjustment patterns properly during Magenta rough adjustment.

 089-610 ERROR — RAP The INNER MOB Sensor failed to detect the rough-adjustment patterns properly during Cyan rough adjustment.

 089-611 ERROR — RAP The CENTER MOB Sensor failed to detect the rough-adjustment patterns properly during Cyan rough adjustment.

 089-612 ERROR — RAP The MOB Sensor OUT failed to detect the rough-adjustment patterns properly during Cyan rough adjustment.

 089-613 ERROR — RAP The INNER MOB Sensor failed to detect the rough-adjustment patterns properly during Black rough adjustment.

 089-614 ERROR — RAP The CENTER MOB Sensor failed to detect the rough-adjustment patterns properly during Black rough adjustment.

 089-615 ERROR — RAP The MOB Sensor OUT failed to detect the rough-adjustment patterns properly during Black rough adjustment.

 089-616 ERROR — RAP RC Data OverFlow Failure.

 089-617 ERROR — RAP RC Data OverRange Failure.

 091-311 ERROR — RAP The voltage level of the CC cleaner position sensor did not change within the specified time.

 091-312 ERROR — RAP Charge (K) Preclean HVPS has failed.

 091-313 ERROR — RAP DRUM CRUM ASIC Communication Failure.

 091-320 ERROR — RAP Charge Corotron Wire is broken.

 091-400 ERROR — RAP The replacement date for Waste Toner Bottle (regular) is near.

 091-401 ERROR — RAP The black drum cartridge is near the end-of-life.

 091-403 ERROR — RAP The CC Assembly is near the end-of-life.

 091-404 ERROR — RAP The CC Assembly has reached the end-of-life.

 091-411 ERROR — RAP The yellow drum cartridge is near the end-of-life.

 091-421 ERROR — RAP The magenta drum cartridge is near the end-of-life.

 091-431 ERROR — RAP The cyan drum cartridge is near the end-of-life.

 091-910 ERROR — RAP The waste toner bottle is not present.

 091-911 ERROR — RAP The waste toner bottle is full.

 091-913 ERROR — RAP The black drum cartridge (K) has reached the end-of-life.

 091-914 ERROR — RAP Communication failure between the MCU and the black Drum CRUM.

 091-915 ERROR — RAP The MCU detected incorrect data in the black drum cartridge CRUM.

 091-916 ERROR — RAP The CRUM authentication registration data on the drum cartridge is incorrect.

 091-917 ERROR — RAP MCU cannot communicate with the CRUM in drum Y.

 091-918 ERROR — RAP Communication failure with the magenta Drum CRUM.

 091-919 ERROR — RAP Communication failure with the cyan Drum CRUM.

 091-920 ERROR — RAP The MCU detected incorrect data in the Yellow drum cartridge CRUM.

 091-921 ERROR — RAP Drum CRUM is disconnected.

 091-922 ERROR — RAP Wrong Data in magenta drum cartridge.

 091-923 ERROR — RAP Wrong data in cyan drum cartridge.

 091-924 ERROR — RAP The CRUM authentication registration data on the yellow drum cartridge is incorrect.

 091-925 ERROR — RAP Wrong data in yellow Magenta cartridge.

 091-926 ERROR — RAP The CRUM authentication registration data on the cyan drum cartridge is incorrect.

 091-927 ERROR — RAP Yellow Drum CRUM is disconnected.

 091-928 ERROR — RAP Magenta Drum CRUM is disconnected.

 091-929 ERROR — RAP Cyan Drum CRUM is disconnected.

 091-932 ERROR — RAP The yellow drum cartridge (Y) has reached the end-of-life.

 091-933 ERROR — RAP The magenta drum cartridge (M) has reached the end-of-life.

 091-934 ERROR — RAP The cyan drum cartridge (C) has reached the end-of-life.

 092-649 ERROR — RAP The MOB ADC Shutter remains open due to shutter failure.

 092-650 ERROR — RAP The MOB ADC Shutter remains closed due to shutter failure.

 092-651 ERROR — RAP The output read by ADC Sensor from the clean Photoreceptor surface is out of range.

 092-652 ERROR — RAP The measured ADC Patch density is light. (Over 75% of Vclean).

 092-653 ERROR — RAP ATC SNR-Yellow output signal failure.

 092-654 ERROR — RAP ATC SNR-Magenta output signal failure.

 092-655 ERROR — RAP ATC SNR-Cyan output signal failure.

 092-656 ERROR — RAP ATC SNR-black output signal failure.

 092-657 ERROR — RAP The amplitude of ATC Yellow Sensor output is out of range.

 092-658 ERROR — RAP The amplitude of ATC Magenta Sensor output is out of range.

 092-659 ERROR — RAP The amplitude of ATC Cyan Sensor output is out of range.

 092-660 ERROR — RAP The amplitude of ATC Black Sensor output is out of range.

 092-661 ERROR — RAP The temperature output of the environment sensor is out of range.

 092-662 ERROR — RAP The humidity output of the environment sensor is out of range.

 092-663 ERROR — RAP The two levels of ADC Patch density created in Mini-Setup are reversed.

 093-300 ERROR — RAP Marking Drawer Interlock Open.

 093-313 ERROR — RAP The Low Toner Sensor failed to detect any toner after the Toner Cartridge Motor was energized.

 093-314 ERROR — RAP Yellow Dispense failure.

 093-315 ERROR — RAP Magenta Dispense failure.

 093-316 ERROR — RAP Cyan Dispense failure.

 093-317 ERROR — RAP Black Dispense failure.

 093-320 ERROR — RAP There was a problem with the developer motor rotation.

 093-421 ERROR — RAP The Black Toner Cartridge (K1) is empty and the Black Toner Cartridge (K2) is near empty.

 093-422 ERROR — RAP The Black Toner Cartridge (K2) is empty and the Black Toner Cartridge (K1) is near empty.

 093-423 ERROR — RAP Yellow toner is near empty.

 093-424 ERROR — RAP Magenta toner is near empty.

 093-425 ERROR — RAP Cyan toner empty.

 093-600 ERROR — RAP Yellow Dispense near failure.

 093-601 ERROR — RAP Magenta Dispense near failure.

 093-602 ERROR — RAP Cyan Dispense near failure.

 093-603 ERROR — RAP Black Dispense near failure.

 093-912 ERROR — RAP The Black Dispense Motor rotation timed out indicating that the Black Cartridge and Reserve Tank are empty.

 093-918 ERROR — RAP A communication failure with Black Toner Cartridge CRUM K2.

 093-924 ERROR — RAP A communication failure with Black Toner Cartridge CRUM K1.

 093-925 ERROR — RAP The data written to the toner CRUM K1 did not agree with the data read.

 093-926 ERROR — RAP Toner Cartridge CRUM K1 Authentication Data is different.

 093-927 ERROR — RAP A communication failure with Yellow Toner Cartridge CRUM Y.

 093-928 ERROR — RAP A communication failure with Magenta Toner Cartridge CRUM M.

 093-929 ERROR — RAP A communication failure with Cyan Toner Cartridge CRUM C.

 093-932 ERROR — RAP Cartridge Exchange Time Over.

 093-934 ERROR — RAP The data written to the toner CRUM M did not agree with the data read.

 093-935 ERROR — RAP The data written to the toner CRUM C did not agree with the data read.

 093-936 ERROR — RAP The data written to the toner CRUM K2 did not agree with the data read.

 093-937 ERROR — RAP Toner Cartridge CRUM Y Authentication Data is different.

 093-938 ERROR — RAP Toner Cartridge CRUM M Authentication Data is different.

 093-939 ERROR — RAP Toner Cartridge CRUM C Authentication Data is different.

 093-940 ERROR — RAP Toner Cartridge CRUM K2 Authentication Data is different.

 094-320 ERROR — RAP Retraction was not detected within the specified time after retraction of the 1st BTR started.

 094-321 ERROR — RAP First BTR Contact Failure.

 094-322 ERROR — RAP Second BTR Retract Failure.

 094-323 ERROR — RAP Contact was not detected within the specified time after contact with the 2nd BTR started.

 102-356 ERROR — RAP Fatal error related to the EWS.

 102-380 ERROR — RAP Fatal error in the MF UI count.

 102-381 ERROR — RAP ESS error during communication between ESS and the control panel.

 102-382 ERROR — RAP A verification message was not returned from the Control Panel within the specified time.

112-700 ERROR — RAP The punch dust box is full.

116-210 ERROR — RAP Media Reader Fatal Error.

116-211 ERROR — RAP Media Reader Cable disconnected.

116-212 ERROR — RAP [Media Reader] MediaLib SW Logic Failure.

116-310 ERROR — RAP An error was detected while checking ESS font ROM DIMM #1.

116-312 ERROR — RAP An error was detected in the HDD encryption key during activation.

116-313 ERROR — RAP An encryption key was specified but the HDD itself was not encrypted.

116-314 ERROR — RAP An ethernet error was detected.

116-315 ERROR — RAP An error was detected during System Memory 1 R/W.

116-316 ERROR — RAP An error was detected during System Memory 2 R/W.

116-317 ERROR — RAP An error was detected when checking the MF ROM.

116-318 ERROR — RAP An error was detected when checking the expansion ROM R2.

116-321 ERROR — RAP System Software Fatal Error.

116-322 ERROR — RAP WebDAV S/W Failure.

116-323 ERROR — RAP An error was detected during the ESS PWB NVM Read/Write Check.

116-324 ERROR — RAP A fatal software exception error has occurred in the Controller PWB CPU.

116-325 ERROR — RAP An error occurred in ESS fan rotation.

116-329 ERROR — RAP A system call error related to the serial I/F was detected.

116-330 ERROR — RAP Error during HDD check.

116-331 ERROR — RAP An error related to the log was detected.

116-332 ERROR — RAP An error in the MF ROM ( ) was detected.

116-333 ERROR — RAP A problem occurred during software processing, and processing could no longer continue.

116-336 ERROR — RAP Redirector HD Failure. A problem was detected during HD access.

116-337 ERROR — RAP Fatal error with SNTP in general.

116-338 ERROR — RAP Fatal error with JBA in general.

116-340 ERROR — RAP There was insufficient page memory, input buffers, or work area.

116-341 ERROR — RAP Incorrect version or invalid combination ROM DIMMs are installed.

116-342 ERROR — RAP Fatal error related to the SNMP agent.

116-343 ERROR — RAP An IC error within the ESS PWB was detected.

116-346 ERROR — RAP Formatter failure. Error return from a system call.

116-348 ERROR — RAP Redirector failure. Error return from a system call.

116-349 ERROR — RAP There was an error with a call within SIF related to Pflite.

116-350 ERROR — RAP Fatal error with AppleTalk in general.

116-351 ERROR — RAP Fatal error related to EtherTalk.

116-352 ERROR — RAP Fatal error related to NetWare.

116-353 ERROR — RAP A physical problem was detected with the HDD during activation, causing the HDD not to activate.

116-354 ERROR — RAP A problem with the HDD product code was detected during activation.

116-355 ERROR — RAP Fatal error related to the SNMP agent.

116-356 ERROR — RAP The HDD was formatted, but an HDD failure occurred.

116-357 ERROR — RAP PostScript fatal system error.

116-358 ERROR — RAP Fatal error related to the salutation.

116-359 ERROR — RAP Fatal error in PLW.

116-360 ERROR — RAP Fatal error related to SMB.

116-361 ERROR — RAP SPL HDD fatal error. SpoolCont detected an error during HDD access.

116-362 ERROR — RAP SSDP software failure.

116-363 ERROR — RAP BMLinkS or print service software failure.

116-364 ERROR — RAP A timer error was detected.

116-365 ERROR — RAP SPL fatal error.

116-366 ERROR — RAP Report generator incorrect operation.

116-367 ERROR — RAP Parallel fatal error.

116-368 ERROR — RAP DumpPrint fatal error.

116-370 ERROR — RAP XJCL fatal error.

116-371 ERROR — RAP PCL Decomposer Software Failure. PCL fatal error.

116-373 ERROR — RAP Fatal error related to Dynamic DNS.

116-374 ERROR — RAP AutoSW fatal error.

116-376 ERROR — RAP Port 9100 Software Fail.

116-378 ERROR — RAP Fatal error related to MCR.

116-379 ERROR — RAP Fatal error related to MCC.

116-380 ERROR — RAP An error was detected while checking ESS font ROM DIMM #1.

116-381 ERROR — RAP The ABL did not agree with the ABL version information in NVM, or the data was corrupted.

116-382 ERROR — RAP An ABL access to NVM or HDD failed.

116-385 ERROR — RAP Fatal error related to the IDC.

116-388 ERROR — RAP It was detected that no HD is installed.

116-389 ERROR — RAP The system detected that no additional RAM was installed.

116-390 ERROR — RAP A version mismatch was detected between the standard ROM and NVM.

116-391 ERROR — RAP Incorrect specification of the country code, territory code, or paper size group.

116-395 ERROR — RAP Fatal error related to the USB.

116-701 ERROR — RAP Duplex printing is not possible due to insufficient memory.

116-702 ERROR — RAP Printing occurred with a substitute font.

116-703 ERROR — RAP PostScript data problem during PostScript grammar interpretation or language interpretation.

116-704 ERROR — RAP MediaReader No Insert (No Job).

116-705 ERROR — RAP MediaReader Format Error (No Job).

116-706 ERROR — RAP MediaReader: File Attribute Read Error (No Job).

116-707 ERROR — RAP MediaReader: Image File Read Error (No Job).

116-708 ERROR — RAP MediaReader: File Attribute Read Error (In Job).

116-709 ERROR — RAP MediaReader: Image File Read Error (Occurs during job).

116-710 ERROR — RAP Original size not correctly determined.

116-711 ERROR — RAP Mismatch in size and direction or ART EX form with paper to be printed.

116-712 ERROR — RAP PLW form / logo data cannot be registered due to insufficient RAM or HD space.

116-713 ERROR — RAP The job was divided because the HDD was full.

116-714 ERROR — RAP An HP-GL/2 (option) command error occurred.

116-715 ERROR — RAP The form could not be registered because the ART EX form registration upper limit was reached.

116-716 ERROR — RAP MediaReader File Does Not Exist.

116-717 ERROR — RAP MediaLib: Not Execute of New Request.

116-718 ERROR — RAP The specified ART EX form has not been registered.

116-720 ERROR — RAP PCL Memory Low, Page Simplified.

116-737 ERROR — RAP User defined data could not be registered because there was insufficient ART IV user definition memory.

116-738 ERROR — RAP Synthesis problem due to the specified ART IV form size and direction were different from the paper size and direction.

116-739 ERROR — RAP Form / logo data could not be registered because there was insufficient ART IV memory or HDD capacity.

116-740 ERROR — RAP An error occurred because the print data exceeded the printer limit.

116-741 ERROR — RAP No more forms can be registered because the number of ART IV Forms registered has reached the upper limit.

116-742 ERROR — RAP No more logo data can be registered because the number of ART IV log data registered has reached the upper limit.

116-743 ERROR — RAP The form or logo data could not be registered due to insufficient ART IV memory.

116-745 ERROR — RAP An ART IV command error occurred.

116-746 ERROR — RAP The specified form has not been registered.

116-747 ERROR — RAP The paper margin value is too large for the HP-GL/2 (option) effective coordinate area.

116-748 ERROR — RAP The HP-GL/2 (option) print data does not contain any image data.

116-749 ERROR — RAP The specified PostScript font is not in ROM or HDD.

116-771 ERROR — RAP Invalid JBIG Parameter DL Fixed.

116-772 ERROR — RAP Invalid JBIG Parameter D Fixed.

116-773 ERROR — RAP Invalid JBIG Parameter P Fixed.

116-774 ERROR — RAP Invalid JBIG Parameter YD Fixed.

116-775 ERROR — RAP Invalid JBIG Parameter LO Fixed.

116-776 ERROR — RAP Invalid JBIG Parameter MX Fixed.

116-777 ERROR — RAP Invalid JBIG Parameter MY Fixed.

116-778 ERROR — RAP Invalid JBIG Parameter VLENGTH Fixed.

116-780 ERROR — RAP There was a problem with the document attached to the received mail.

116-790 ERROR — RAP Stapling was cancelled.

123-200 ERROR — RAP The data received from ESS exceeded the buffer size of the storage destination within the control panel.

123-201 ERROR — RAP Data intended to be received from the control panel exceeded the buffer size of the storage destination within the control panel.

123-202 ERROR — RAP Events occurred that exceeded the processing capability for requests generated within the control panel.

123-203 ERROR — RAP UI Debug code.

123-204 ERROR — RAP SIO Parameter Failure (UI-Control panel).

123-205 ERROR — RAP SIO Command Failure (UI-Control panel).

123-206 ERROR — RAP SIO Status Failure (UI-Control panel).

123-207 ERROR — RAP Comm Manager Target Failure (UI-Control panel).

123-208 ERROR — RAP Comm Manager Command Failure (UI-Control panel).

123-209 ERROR — RAP EVM Returns Wrong Value (UI-Control panel).

123-310 ERROR — RAP Send Queue Full (UI-Control panel).

123-311 ERROR — RAP Receive Queue Full (UI-Control panel).

123-312 ERROR — RAP EVM Uses Wrong API (UI-Control panel).

123-313 ERROR — RAP AS Uses Wrong API (UI-Control panel).

123-314 ERROR — RAP Event-Waiting Timer Timeout (UI-Control panel).

123-315 ERROR — RAP CTS Internal Failure (UI-Control panel).

123-316 ERROR — RAP Send Request Queue Full SIO (UI-Control panel).

123-317 ERROR — RAP Receive Message Queue Full (UI-Control panel).

123-318 ERROR — RAP Receive Finish Queue Full (UI-Control panel).

123-319 ERROR — RAP Send Failure with No ACK (UI-Control panel).

123-320 ERROR — RAP Polling Failure (UI-Control panel).

123-321 ERROR — RAP Send Message Failure (UI-Control panel).

123-322 ERROR — RAP Target Failure (UI-Control panel).

123-323 ERROR — RAP Address Failure (UI-Control panel). Serial communication error.

123-324 ERROR — RAP Size Failure (UI-Control panel). Serial communication error.

123-325 ERROR — RAP Object Creation Failure (UI-Control panel).

123-326 ERROR — RAP Memory Overflow (UI-Control panel).

123-327 ERROR — RAP Button Overflow (UI-Control panel).

123-328 ERROR — RAP UI Internal Failure with Out of Area.

123-329 ERROR — RAP UI Internal Failure with Invalid Coordinates.

123-330 ERROR — RAP Interface Failure with Invalid Parameter LCD.

123-331 ERROR — RAP UI Internal Failure with Invalid LED Request.

123-332 ERROR — RAP I/F Failure (Invalid Parameter CP).

123-333 ERROR — RAP I/F Failure (No Communication).

123-334 ERROR — RAP I/F Failure (Receiving Error Key Code).

123-335 ERROR — RAP I/F Failure (Receiving Invalid Coordinates).

123-336 ERROR — RAP I/F Failure (DM-ACD Drv. I/F).

123-337 ERROR — RAP Frame Data Error with Invalid Data Type.

123-338 ERROR — RAP Frame Data Error Offset Address Out.

123-339 ERROR — RAP Display Request Code Invalid.

123-340 ERROR — RAP Interface Failure GUAM-DM I/F.

123-341 ERROR — RAP Event Queue Full (UI-Control panel).

123-342 ERROR — RAP Event Queue Empty (UI-Control panel).

123-343 ERROR — RAP Invalid Class (UI-Control panel).

123-344 ERROR — RAP Invalid Type (UI-Control panel).

123-345 ERROR — RAP Timer Queue Full (UI-Control panel).

123-346 ERROR — RAP Invalid Timer Number (UI-Control panel).

123-347 ERROR — RAP Undefined Trap (UI-Control panel).

123-348 ERROR — RAP Command Access Exception (UI-Control panel).

123-349 ERROR — RAP Invalid Command (UI-Control panel).

123-350 ERROR — RAP Privilege Command (UI-Control panel).

123-351 ERROR — RAP No FPU Exception (UI-Control panel).

123-352 ERROR — RAP Address Mis-align (UI-Control panel).

123-353 ERROR — RAP Data Access Exception (UI-Control panel).

123-354 ERROR — RAP Tag Overflow (UI-Control panel).

123-355 ERROR — RAP No Co Processor Exception (UI-Control panel).

123-356 ERROR — RAP Short of Area (UI-Control panel).

123-357 ERROR — RAP Cancel Wait Status (UI-Control panel).

123-358 ERROR — RAP Timeout (UI-Control panel).

123-359 ERROR — RAP Queue Overflow (UI-Control panel).

123-360 ERROR — RAP Context Failure (UI-Control panel).

123-361 ERROR — RAP Object Failure (UI-Control panel).

123-362 ERROR — RAP No Object (UI-Control panel).

123-363 ERROR — RAP Invalid ID (UI-Control panel).

123-364 ERROR — RAP Parameter Failure (UI-Control panel).

123-365 ERROR — RAP Reserve Attribute (UI-Control panel).

123-366 ERROR — RAP Reserve Function Code (UI-Control panel).

123-367 ERROR — RAP Unsupported Function (UI-Control panel).

123-368 ERROR — RAP Short of UI Memory (UI-Control panel).

123-369 ERROR — RAP Invalid Interface Value (UI-Control panel).

123-370 ERROR — RAP Interface Length Failure (UI-Control panel).

123-371 ERROR — RAP Interface Parameter Failure (UI-Control panel).

123-372 ERROR — RAP Interface Sequence Failure (UI-Control panel).

123-373 ERROR — RAP Channel Failure (UI-Control panel).

123-374 ERROR — RAP Invalid User Job ID (UI-Control panel).

123-375 ERROR — RAP Internal Resource Failure (UI-Control panel).

123-376 ERROR — RAP Internal Memory Failure (UI-Control panel).

123-377 ERROR — RAP UI Timer Failure (UI-Control panel).

123-378 ERROR — RAP Interface Format Failure (UI-Control panel).

123-379 ERROR — RAP Dispatch Failure (UI-Control panel).

123-380 ERROR — RAP Copy Interface Failure (UI-Control panel).

123-382 ERROR — RAP Scanner Interface Failure (UI-Control panel).

123-383 ERROR — RAP Report Interface Failure (UI-Control panel).

123-384 ERROR — RAP Server Access Failure (UI-Control panel).

123-385 ERROR — RAP Service Object Overflow (UI-Control panel).

123-386 ERROR — RAP Invalid Service Object (UI-Control panel).

123-387 ERROR — RAP Invalid Service Object Attribute (UI-Control panel).

123-388 ERROR — RAP Attribute Failure (UI-Control panel).

123-389 ERROR — RAP Argument Failure (UI-Control panel).

123-390 ERROR — RAP Job Parameter Failure (UI-Control panel).

123-391 ERROR — RAP Job Actual Parameter Failure (UI-Control panel).

123-392 ERROR — RAP Auditron Failure (UI-Control panel).

123-393 ERROR — RAP EP Failure (UI-Control panel).

123-394 ERROR — RAP File Access Failure (UI-Control panel).

123-395 ERROR — RAP NVM Failure (UI-Control panel).

123-396 ERROR — RAP FF Failure (UI-Control panel).

123-397 ERROR — RAP MGR Failure (UI-Control panel).

123-398 ERROR — RAP Delay Release Queue Full (UI-Control panel).

123-399 ERROR — RAP Internal Failure (UI-Control panel).

123-400 ERROR — RAP Internal Failure (UI-Control panel).

124-310 ERROR — RAP DC132 11 — The product number was not specified.

124-311 ERROR — RAP DC132 09 — The serial number registration field failed.

124-312 ERROR — RAP DC132 12 — Product numbers did not agree.

124-313 ERROR — RAP DC132 10 — Serial numbers did not agree.

124-314 ERROR — RAP DC 132-01 — IOT Speed Failure.

124-315 ERROR — RAP DC 132-02 — IOT Speed Mismatch.

124-316 ERROR — RAP DC 132-04 — Product a/f Model Failure.

124-317 ERROR — RAP DC 132-04 — Product a/f All Product Model Mismatch.

124-318 ERROR — RAP Product Type for S/W Key Failure.

124-319 ERROR — RAP DC 132-08 — All Product Type For S/W Key Mismatch.

124-320 ERROR — RAP EEP ROM Failure.

124-321 ERROR — RAP Backup SRAM Failure. An NVM ROM write problem occurred on the ESS PWB.

124-322 ERROR — RAP DC 132-05 — Copy/Scan/Print S/W Key by PWE Failure.

124-323 ERROR — RAP DC 132-06 — Copy/Scan/Print S/W Key 1 Failure.

124-324 ERROR — RAP All Billings Mismatch.

124-325 ERROR — RAP Billing Restoration Failure.

124-333 ERROR — RAP ASIC Failure (Panther).

124-334 ERROR — RAP Standard Font ROM Error.

124-335 ERROR — RAP Font ROM Not Found.

124-337 ERROR — RAP ESS Standard RAM Error.

124-338 ERROR — RAP Same Font ROMs Found.

124-339 ERROR — RAP ROM DIMM of another product found.

124-340 ERROR — RAP The three CRUM market destination values are not set up (0 or different).

124-341 ERROR — RAP One CRUM market destination value is different (IOT).

124-342 ERROR — RAP One CRUM market destination value is different (SYS 1).

124-343 ERROR — RAP One CRUM market destination value is different (SYS 2).

124-350 ERROR — RAP The three CRUM OEM destination values are not set up (0 or different).

124-351 ERROR — RAP One CRUM OEM destination value is different (IOT).

124-352 ERROR — RAP One CRUM OEM destination value is different (SYS 1).

124-353 ERROR — RAP One CRUM OEM destination value is different (SYS 2).

124-360 ERROR — RAP CRUM Valid/Invalid is not set up at the three locations (0 or different values).

124-361 ERROR — RAP CRUM Validation Failure MCU.

124-362 ERROR — RAP CRUM Validation Failure SYS 1.

124-363 ERROR — RAP CRUM Validation Failure SYS 2.

124-372 ERROR — RAP IOT sc Soft Failure.

124-373 ERROR — RAP IOT Manager SW Failure.

124-374 ERROR — RAP IOT IM Device Driver SW Failure.

124-380 ERROR — RAP CRUM Market fail ALL (2).

124-381 ERROR — RAP CRUM Market fail MCU (2).

124-382 ERROR — RAP CRUM Market fail SYS 1 (2).

124-383 ERROR — RAP CRUM Market fail SYS 2 (2).

124-390 ERROR — RAP CRUM OEM fail ALL (2).

124-391 ERROR — RAP CRUM OEM fail MCU (2).

124-392 ERROR — RAP CRUM OEM fail SYS 1 (2).

124-393 ERROR — RAP CRUM OEM fail SYS 2 (2).

124-701 ERROR — RAP Side Tray to Center Tray.

124-704 ERROR — RAP The output tray was changed from the Folder Tray to the Center Tray and printing continued.

124-705 ERROR — RAP Punching Cancelled.

124-706 ERROR — RAP Folding Cancelled.

124-708 ERROR — RAP The output tray has been changed to the Sub Tray because a failure was detected in the specified output tray.

124-709 ERROR — RAP Stapler Sheet Count is too high.

125-311 ERROR — RAP PSWcont Unexpected Failure.

127-210 ERROR — RAP DFE Communication Failure.

127-211 ERROR — RAP DFE Parameter Error.

127-212 ERROR — RAP ExtPrint Check Mode Error.

127-213 ERROR — RAP External Print IF Mismatch.

127-220 ERROR — RAP Communication Error (video) detected by the DFE.

127-221 ERROR — RAP Communication Error (Command) detected by the DFE.

127-310 ERROR — RAP ESR Task Fatal Error.

127-311 ERROR — RAP ExtPRT.

127-320 ERROR — RAP DFE Critical Failure.

127-337 ERROR — RAP Job Template HDD Write Error.

127-342 ERROR — RAP Job Template Monitor Failure.

127-353 ERROR — RAP LPD Soft Fatal Error.

127-354 ERROR — RAP FTP Server Software Failure.

127-396 ERROR — RAP Mail I/O Soft Fatal error.

127-398 ERROR — RAP IPP Soft Fatal Error.

127-399 ERROR — RAP JME Soft Fatal Error.

202-399 ERROR — RAP Timer Internal Fail.

– Compatible Printer model: Xerox WorkCentre 6515
– Xerox WorkCentre 6515 Error Codes with quick guides:

  • Code: 002-500
  • Description: UI Error RAP
    002-500 CUI scan panel UI detection error.
  • Troubleshooting Guides: 1. Switch off then switch on the machine, GP 4.
    2. Ensure that all connectors on the UI assembly, PL 1.1 Item 1 and the ESS Board, PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP) are securely connected. Ensure that all surface mounted modules on the ESS Board are securely connected.
    3. Check the wiring between the ESS Board and the UI assembly.
    4. Reload the software, GP 9. 5. If the fault persists, install a new components as necessary: • UI assembly, REP 1.1.1. • ESS Board, REP 18.1.5 (MFP), REP 18.5.5 (SFP).
  • Code: 003-311
  • Description: IIT CDI I/F Mismatch
    003-311 During controller initialization, the IIT CDI I/F has insufficient information from the IIT.
  • Troubleshooting Guides: 1. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    2. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    3. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    4. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    5. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    6. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-318, 003-319
  • Description: IIT Software Fail
    003-318 IIT software is corrupt.
    003-319 Video driver detection fail.
  • Troubleshooting Guides: 1. Switch off then switch on the machine, GP 4.
    2. Ensure that all connectors on the MCU Board, PL 18.1 Item 1 (MFP), PL 18.1 Item 5 (SFP) and the ESS Board, PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP) are securely connected. Make sure all surface mounted modules on both Boards are securely connected.
    3. Reload the software, GP 9.
    4. If the fault persists, install a new ESS Board, REP 18.1.5 (MFP), REP 18.5.5 (SFP).
  • Code: 003-320 … 003-343
  • Description: IISS-ESS Communication Fail
    003-320 IISS sending error 1 detected by the controller. An abnormal parameter is set as the argument for the send function.
    003-321 IISS sending error 2 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-322 IISS sending error 3 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-323 IISS sending error 4 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-324 IISS sending error 5 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-325 IISS sending error 6 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-326 IISS sending error 7 detected by the controller. After commands were the controller, the controller could not receive acknowledgment from the IISS.
    003-327 IISS sending error 8 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-328 IISS sending error 9 detected by the controller. After commands were sent twice from the controller, the controller could not receive acknowledgment from the IISS.
    003-329 IISS receiving error 10 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-330 IISS receiving error 11 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-331 IISS receiving error 12 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-332 IISS receiving error 13 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-333 IISS receiving error 14 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-334 IISS receiving error 15 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-335 IISS receiving error 16 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-336 IISS receiving error 17 detected by the controller. The NAK that notifies of the occurrence of a transmission failure is received.
    003-337 IISS receiving error 18 detected by the controller. There was no response to the power on command sent to the IISS after restoring from power saver mode.
    003-338 IISS receiving error 19 detected by the controller. Incorrect argument error for sending.
    003-339 IISS receiving error 20 detected by the controller. Transmission establishing error for sending.
    003-340 IISS receiving error 21 detected by the controller. Synchronous send error.
    003-341 IISS receiving error 22 detected by the controller. Transmission error for sending.
    003-342 IISS receiving error 23 detected by the controller. Incorrect argument error for receiving.
    003-343 IISS receiving error 24 detected by the controller. Synchronous receive error.
  • Troubleshooting Guides: 1. Switch off then switch on the machine, GP 4.
    2. Ensure that all connectors on the MCU Board, PL 18.1 Item 1 (MFP), PL 18.1 Item 5 (SFP) and the ESS Board are securely connected. Make sure all surface mounted modules on both Boards are securely connected.
    3. Reload the software, GP 9.
    4. If the fault persists, install a new ESS Board, REP 18.1.5 (MFP), REP 18.5.5 (SFP).
  • Code: 003-344
  • Description: IISS-ESS X Hotline Fail
    003-344 X Hotline failure during power on.
  • Troubleshooting Guides: 1. Switch off then switch on the machine, GP 4.
    2. Ensure that all connectors on the MCU Board, PL 18.1 Item 1(MFP), PL 18.1 Item 5 (SFP) and the ESS Board are securely connected. Make sure all surface mounted modules on both Boards are securely connected.
    3. Reload the software, GP 4.
    4. If the fault persists, install a new ESS Board, REP 18.1.5(MFP), REP 18.5.5(SFP).
  • Code: 003-345, 003-346
  • Description: PIO Mismatch RAP
    003-345 X PIO Unmatch Fail 1 When a job fail was received from the IISS, an error of the X hot line was detected.
    003-345 X PIO Unmatch Fail 2 When IIT image delivered was received from the IISS, an error of the X hot line was detected.
  • Troubleshooting Guides: 1. Switch off then switch on the machine, GP 4.
    2. Ensure that all connectors on the MCU Board, PL 18.1 Item 1 (MFP), PL 18.1 Item 5 (SFP), and the ESS Board, PL 18.5 Item 1 (MFP) PL 18.5 Item 5 (SFP) are securely connected. Make sure all surface mounted modules on both Boards are securely connected.
    3. Reload the software, GP 4.
    4. If the fault persists, install a new ESS Board, REP 18.5.1 (MFP), REP 18.5.5 (SFP).
  • Code: 003-700
  • Description: Returned Documents Error RAP
    003-700 When the originals are ejected, the number of ejected originals is more than the number that were fed.
  • Troubleshooting Guides: Reload the originals, then re-run the job.
  • Code: 003-701
  • Description: Duplication Prevention Code RAP
    003-701 A copy restriction code is detected in the document data.
  • Troubleshooting Guides: 1. Advise the customer not to attempt to copy documents that are restricted.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-702
  • Description: Different Magnification RAP
    003-702 Different magnification settings, for side 1 and side 2 of a document.
  • Troubleshooting Guides: 1. Advise the customer to correct the magnification settings.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-703, 003-704
  • Description: Color Correction RAP
    003-703 Color correction patch position error during 2 sided simultaneous scan.
    003-704 Color correction color difference error during 2 sided simultaneous scan.
  • Troubleshooting Guides: 1. Advise the customer to load the 2 sided simultaneous scan correction chart correctly.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-705
  • Description: Energy Saving Paper Size Mismatch RAP
    003-705 A paper size mismatch error was detected when exiting energy saver mode.
  • Troubleshooting Guides: 1. Advise the customer to cancel the job, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-750
  • Description: Insufficient Documents Duplex Book RAP
    003-750 The number of documents is insufficient for duplex book print.
  • Troubleshooting Guides: 1. Advise the customer to change the parameters, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.

Xerox WorkCentre 6515 error and solving error codes

Solve Xerox WorkCentre 6515 Error codes

  • Code: 003-751
  • Description: Capacity RAP
    003-751 According to the document area settings and the scan area, processing image data with a size smaller than the one that can be processed was detected.
  • Troubleshooting Guides: 1. Advise the customer to increase the resolution or enlarge the scan area (width x length), then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-752, 003-932, 003-935
  • Description: 600dpi Cannot be Scanned RAP
    003-752 600dpi is unavailable for DADF mixed 2-sided mode scan.
    003-932 For scanning in the DADF mix duplex mode, 600dpi is not available.
    003-935 For scanning in the DADF mix duplex mode, 600dpi is not available (when the next document exists).
  • Troubleshooting Guides: 1. Advise the customer to perform scanning below 400 dpi resolution.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-753, 003-913, 003-933
  • Description: 300dpi Cannot be Scanned RAP
    003-753 300/400/600dpi unavailable for DADF mixed 2-sided mode scan.
    003-913, 930 For scanning in the DADF mix duplex mode, 300dpi, 400dpi and 600dpi are not available.
    003-933 For scanning in the DADF mix duplex mode, 300dpi, 400dpi and 600dpi are not available (when the next document exists).
  • Troubleshooting Guides: 1. Advise the customer to perform scanning below 200 dpi resolution or perform scanning in other than mixed mode.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-754, 003-756
  • Description: S2X Error RAP
    003-754 A recoverable error was detected.
    003-756 All scanned documents were detected as blank.
  • Troubleshooting Guides: 1. Advise the customer to cancel the job, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-757, 003-9931, 003-934
  • Description: 400dpi Cannot be Scanned RAP
    003-757 400/600dpi unavailable for DADF mixed 2-sided mode scan.
    003-931 For scanning in the DADF mix duplex mode, 400dpi and 600dpi are not available.
    003-934 For scanning in the DADF mix duplex mode, 400dpi and 600dpi are not available (when the next document exists).
  • Troubleshooting Guides: 1. Advise the customer to perform scanning below 300 dpi resolution or perform scanning in other than mixed mode.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-760, 003-761
  • Description: Scan Settings Error RAP
    003-760 The job properties are incorrect.
    003-761 Tray selection error.
  • Troubleshooting Guides: 1. Advise the customer to correct the job properties.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-763
  • Description: Adjustment Chart Not Found RAP
    003-763 The chart patch could not be detected.
  • Troubleshooting Guides: 1. Advise the customer to place the Auto Gradation Correction Chart correctly.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-764
  • Description: Document Insufficient (image overlay) RAP
    003-764 During Image Overlay, only 1 page can be stored (B/W Macines Only).
  • Troubleshooting Guides: 1. Advise the customer to cancel the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-780
  • Description: Scan Image Compression Error RAP
    003-780 Scan compression error.
  • Troubleshooting Guides: 1. Advise the customer to cancel the job then to change the scan resolution parameter and then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-795
  • Description: AMS Limit Error RAP
    003-795 AMS (auto reduce/enlarge) limit error.
  • Troubleshooting Guides: 1. Advise the customer to cancel the job then to change the job properties.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-940
  • Description: Insufficient Memory RAP
    003-940 Insufficient DAM memory detected.
  • Troubleshooting Guides: 1. Advise the customer to cancel the job then to clear the B/W setting for color mode or the side 2 cover image setting, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-941
  • Description: Insufficient Page Memory RAP
    003-941 There is not enough page memory to store the image.
  • Troubleshooting Guides: 1. Advise the customer to change the parameter(s), then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-942, 003-956
  • Description: Document Size Auto Detect RAP
    003-942 The document size cannot be automatically detected.
    003-956 Undefined document size was detected when platen is selected and only APS requires document size selection.
  • Troubleshooting Guides: 1. Advise the customer to input an appropriate value for the document size, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-944
  • Description: Repeat Image Count Fail RAP
    003-944 Incorrect image repeat count (even one image cannot be pasted).
  • Troubleshooting Guides: 1. Advise the customer to change the image repeat count parameter, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-946
  • Description: Image Rotation (Copy APS) RAP
    003-946 Part of the image will be lost if the image is not rotated. However, a paper size that does not support rotation was selected.
  • Troubleshooting Guides: 1. Advise the customer to manually select an appropriate paper tray, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-947, 003-948
  • Description: Document Error RAP
    003-947 An additional number of documents are required.
    003-948 Returned document size mismatch.
  • Troubleshooting Guides: 1. Advise the customer to reload the correct number and size of documents, and to correctly program the job on the UI. Retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-952
  • Description: Document Color Mismatch RAP
    003-952 Returned document color mismatch (different color detected before/after return).
  • Troubleshooting Guides: 1. Advise the customer to correct the job settings, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-955
  • Description: Documents Size Exchange Error RAP
    003-955 When loading a document with Mixed Size Originals prohibited, a document of different size/orientation from the initial document was detected.
    • Only Image Overlay has the function that inhibits different sizes during document added.
  • Troubleshooting Guides: 1. Advise the customer to reload the document then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-956
  • Description: Documents Size Unknown Error RAP
    003-956 Undefined document size was detected when Platen is selected and only APS requires document size selection.
  • Troubleshooting Guides: 1. Advise the customer to verify the correct document size for the job, change if needed, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-963, 003-965, 003-966
  • Description: ATS/APS RAP
    003-963 No APS compatible tray to set the relevant size.
    003-965 There was no paper in the tray that can be selected for APS.
    003-966 There is no APS tray that is set to a specific size selected.
  • Troubleshooting Guides: 1. Advise the customer to select a tray that has the correct size of paper, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-970, 003-976
  • Description: FAX Line Memory RAP
    003-970 The number of slow-scan lines has exceeded the upper limit due to FAX parallel composition, long- document enlargement, etc.
    003-976 Number of lines in the slow scan direction exceeded during FAX N-up.
  • Troubleshooting Guides: 1. Advise the customer to press the continue button to store as much data as the memory capacity, then continue scanning the next document. Otherwise, cancel the job.
    2. Switch off then switch on the machine, GP 10.
    3. If the fault persists, reload the software, GP 4.
  • Code: 003-971
  • Description: Prevention Code Detect With The Right To Cancel RAP
    03-971 When job scan was executed by a user who has the permission to temporarily clear the copy restriction code detection, copy restriction codes were detected in the document.
  • Troubleshooting Guides: 1. Advise the customer that because this document cannot be copied, press the “Cancel” or “Continue” button on the panel.
    2. If the fault persists, reload the software, GP 4.
  • Code: 003-972
  • Description: Maximum Stored Page RAP
    003-972 When scanning a document, the number of pages that has accumulated in the machine has exceeded the value of ’Maximum Stored Number of Copy Sheets’ set in system data.
  • Troubleshooting Guides: 1. Advise the customer to set the number of pages of the document to be within the maximum number of pages that can be stored.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-973
  • Description: Image Rotation RAP
    003-973 The document and the image are different in orientation (except when poster is specified). When rotation is not available even though the orientation of the document and the image are different and part of the image will be lost if it is not rotated.
  • Troubleshooting Guides: 1. Advise the customer to verify the image loss and use a larger paper size if available. Or use reduction to make a smaller document, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-974
  • Description: Next Original Specification RAP
    003-974 Next document specified. Scanning has been completed for all loaded documents.
  • Troubleshooting Guides: 1. Ask the customer to verify that scanning is complete or if other documents should be loaded.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-977
  • Description: Document Mismatch (Multi Scan) RAP
    003-977 Document size mismatch (document exchange during multi scan).
  • Troubleshooting Guides: 1. Ask the customer to load a correct size document, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 003-978
  • Description: Color Document Mismatch (Multi Scan) RAP
    003-978 Document color mismatch (document replacement during multi scan).
  • Troubleshooting Guides: 1. Advise the customer to reload the correct size paper, then retry the job.
    2. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to obtain the log, set NVM (700-530) to “0” to perform log collection and return the NVM (700- 530) to “1” after completing the procedure.
    3. Change any possible mechanical settings for corrective actions or detection conditions and repeat the operation.
    4. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to GP 9 Firmware Version Upgrade)
    5. Switch the power off then on.Get the procedures for reproducing an error according to the operation that was performed when the error occurred. a. Check the exact occurrence timing during job execution. b. Check the job settings from the Panel. c. Collect other information as much as possible to reproduce the error.
    6. Obtain logs immediately after the error has occurred without turning the power off and on. Perform 2.6 Log RAP.
    7. The ESS Board rarely fails, contact Technical Support for further instructions.
  • Code: 005-121, 005-123, 005-124, 005-125
  • Description: DADF JAM RAP
    005-121 Jam in the Document Feeder.
    005-123 Jam in the Document Feeder.
    005-124 Virtual JAM.
    005-125 Jam in the Document Feeder.
    Possible Parts Affected DADF ASSY PL 50.1 Item 1 FEEDER ROLL DADF PL 50.1 Item 5 ESS Board PL 18.1 Item 5
  • Troubleshooting Guides: 1. Verify no obstructions in the paper path and the document meets the feeder specification.
    2. Verify there are no obstructions of the DADF ASSY and the DADF ASSY closes against the platen glass correctly.
    3. Check the connection at the DADF ASSY and the ESS Board, verify P/J1371 and P/ J1377 are fully seated.
    4. Verify proper installation and condition of the DADF ASSY looking for any unusual wear or damage.
    5. Install a new DADF Feed Roller Kit REP 50.1.99
    6. Install a new DADF ASSY REP 50.1.1
    7. Iinstall a new ESS Board REP 18.1.5
  • Code: 005-210, 005-275, 005-305
  • Description: DADF JAM RAP
    005-210 DADF Download Fail
    005-275 DADF RAM Fail.
    005-305 The Document Feeder Cover is Open.
    Possible Parts Affected DADF ASSY PL 50.1 Item 1 FEEDER ROLL DADF PL 50.1 Item 5 ESS Board PL 18.1 Item 5
  • Troubleshooting Guides: 1. Verify no obstructions in the paper path and the document meets the feeder specification.
    2. Verify there are no obstructions of the DADF ASSY and the DADF ASSY closes against the platen glass correctly.
    3. Check the connection at the DADF ASSY and the ESS Board, verify P/J1371 and P/ J1377 are fully seated.
    4. Verify proper installation and condition of the DADF ASSY looking for any unusual wear or damage.
    5. Install a new DADF Feed Roller Kit REP 50.1.99
    6. Install a new DADF ASSY REP 50.1.1
    7. Iinstall a new ESS Board REP 18.1.5
  • Code: 005-500
  • Description: Write to DADF-ROM Error RAP
    005-500 An error has occurred during the process of writing data to the DADF-ROM.
  • Troubleshooting Guides: 1. Reload the software, GP 4
    2. Install a new DADF ASSY REP 50.1.1
  • Code: 005-906, 005-908, 005-911, 005-940
  • Description: DADF JAM RAP
    005-906 JAM in the Document Feeder.
    005-908 JAM in the Document Feeder.
    005-911 JAM in the Document Feeder.
    005-940 A document was pulled out during document feed.
    Possible Parts Affected DADF ASSY PL 50.1 Item 1 FEEDER ROLL DADF PL 50.1 Item 5 ESS Board PL 18.1 Item 5
  • Troubleshooting Guides: 1. Verify no obstructions in the paper path and the document meets the feeder specification.
    2. Verify there are no obstructions of the DADF ASSY and the DADF ASSY closes against the platen glass correctly.
    3. Check the connection at the DADF ASSY and the ESS Board, verify P/J1371 and P/ J1377 are fully seated.
    4. Verify proper installation and condition of the DADF ASSY looking for any unusual wear or damage.
    5. Install a new DADF Feed Roller Kit REP 50.1.99
    6. Install a new DADF ASSY REP 50.1.1
    7. Iinstall a new ESS Board REP 18.1.5
  • Code: 005-941
  • Description: Not Enough Documents RAP
    005-941 Some originals were missing after all originals were returned.
  • Troubleshooting Guides: 1. Reset documents in accordance with UI.
    2. Cancel all jobs and restart the job again.
  • Code: 010-105, 010-106
  • Description: FUSING ASSY Exit Sensor RAP
    010-105 FUSING ASSY Exit SNR ON – After Regi Clutch ON, Exit Sensor is not turned OFF by paper within specified time.
    • MFP: Jam in the Device – Error 010-105
    • SFP: Paper Jam – Open Rear Door and Inner Door
    110-106 FUSING ASSY Exit SNR OFF – After Regi Clutch OFF, Exit Sensor is not turned ON by paper within specified time.
    • MFP: Jam in the Device – Error 010-106
    • SFP: Paper Jam – Open Rear Door and Inner DooR
    Possible Parts Affected
    • KIT COVER ASSY REAR PL 19.2 Item 99
    • Exit Sensor [FUSING ASSY] PL 7.1 Item 1
    • CHUTE ASSY EXIT PL 17.1 Item 1
    • Exit Clutch [DRIVE ASSY EXIT MAIN] PL 17.1 Item 4
    • MCU Board, PL 18.1 Item 1 (MFP), PL 18.5 Item 1 (SFP)
  • Troubleshooting Guides: 1. Verify no obstructions in the paper path and the document meets the feeder specification.
    2. Verify the REAR COVER PL 19.2 Item 12 is not damaged. a. Install a new KIT COVER ASSY REAR PL 19.2 Item 99
    3. Verify the CHUTE ASSY EXIT PL 17.1 Item 1 is not damaged. a. Install a new Exit Chute Assembly REP 17.1.1 4. Reseat the FUSING ASSY PL 7.1 Item 1
    5. Execute the diagnosis dC330 [071-104], and check the Exit Sensor operation. a. Check the connection between the Exit Sensor and the MCU Board at P/J270 and P/ J272 and verify they are fully seated (Refer to Figure 1). b. Check the continuity between the Exit Sensor and the Relay Connector, verifying each cable of P/J270<=>P/J272 for continuity. c. Check the voltage between the MCU Board ground and the P/J272-3 pin is about +5 VDC. i. Check the connection at the LVPS Board and the MCU Board P/J284 and P/ J280 are fully seated. ii. Check the continuity between the LVPS Board and the MCU Board verify each cable of P/J284<=>P/J280. iii. Check the voltage from the LVPS Board (+5 VDC). Voltage between the LVPS Board ground and the P/J284-5 pin should be about +5 VDC. iv. Check the connections at LVPS Board and the MCU Board, P/J284 and P/J280 are fully seated. v. Check continuity between the LVPS Board and the MCU Board verify each cable of P/J284<=>P/J280 is continuous. • Install a new or repair the LV MCU HARNESS ASSY PL 18.4 Item 5 (MFP) PL 18.8 Item 5 (SFP). vi. Check the voltage from the LVPS Board ground and the P/J284-5 pin is about +5 VDC. d. Install a new CHUTE ASSY EXIT REP 17.1.1
    6. Execute the diagnosis dC330 [071-105], and check the Exit Clutch operation.
    7. Check the connection between the Exit Clutch and the MCU Board at P/J460 and P/J462 and verify they are fully seated (Refer to Figure 2).
    8. Check the continuity between the Exit Clutch and the Relay Connector, verifying each cable of P/J460<=>P/J462 for continuity.
    9. Close all interlock switches. Voltage between the MCU Board ground and the P/J460-4 pin should read approximately +24VDC. a. Check the connections at the LVPS Board and the MCU Board, verify P/J284 and P/ J280 are fully seated. b. Check continuity between the LVPS Board and the MCU Board verify each cable of P/J284<=>P/J280 is continuous. • Install a new or repair the LV MCU HARNESS ASSY PL 18.4 Item 5 (MFP) PL 18.8 Item 5 (SFP). c. Close all interlock switches and verify the voltage from the LVPS Board ground and the P/J284-18 pin and the voltage from the LVPS Board ground and the P/J284-20 pin is about +24 VDC.
    10. Install a new Main Exit Drive Assembly REP 17.1.4
    11. Install a new Fuser REP 7.1.1
    12. Power the machine down then back up, GP 4 .
    13. If the fault persists, install a new MCU Board REP 18.1.1(MFP) REP 18.5.1(SFP)
  • Code: 010-331, 010-338, 010-344
  • Description: FUSING ASSY RAP
    010-331: FUSING ASSY HR STS Over Temperature Fail
    010-338: FUSING ASSY HR On Time Fail (Wait) 010-344: FUSING ASSY HR STS Low Temperature Fail
    Possible Parts Affected
    • FUSING ASSY PL 7.1 Item 1
    • Fuser Harness (DC) (J270-J272, J273) PL 18.3 Item 2 (MFP) PL 18.7 Item 2 (SFP)
    • Fuser Harness (AC) 110VAC (J283-P275) PL 18.3 Item 3A (MFP) PL 18.7 Item 3A (SFP)
    • Fuser Harness (AC) 220VAC(J283-P275) PL 18.3 Item 3B (MFP) PL 18.7 Item 3B (SFP)
    • LV MCU Harness Assy (J280-J284) PL 18.4 Item 5 (MFP) PL 18.8 Item 5(SFP)
    • LVPS Board PL 18.1 Item 16 (MFP), PL 18.5 Item 16 (SFP)
    • MCU Board, PL 18.1 Item 1 (MFP), PL 18.5 Item 1 (SFP)
  • Troubleshooting Guides: 1. Verify the FUSING ASSY and the drawer connector of the printer are installed properly (without a bent pin, or any foreign or burnt objects, etc.).
    2. Check the connection between the FUSING ASSY and the MCU Board and FUSING ASSY and LVPS Board (P/J283, P/J275, P/J270, and P/J273) are fully seated. (Refer to Figure 1).
    3. Check the connection between the LVPS Board and the MCU Board (P/J284, P/J280) are fully seated.
    4. Check the continuity between the Fuser Harness (AC) 110VAC in each cable of P/ J283<=>P/J275. • Install a new Fuser Harness (AC) 110VAC.
    5. Check the continuity between the LV MCU Harness Assy (J280-J284) in each cable of P/ J284<=>P/J280. • Install a new LV MCU HARNESS ASSY PL 18.4 Item 5.
    6. Install a new MCU Board, REP 18.1.1 (MFP), REP 18.5.1 (SFP)
    7. Install a new LVPS Board REP 18.1.16 (MFP) REP 18.5.16 (SFP)
  • Code: 016-211, 016-212
  • Description: SW Option Fail Memory Low RAP
    016-211 Insufficient system memory was detected.
    016-212 Insufficient Page Memory was detected.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Refer the customer to the User Guide to check memory usage.
  • Code: 016-214
  • Description: SW Option Fail (FAX Card) RAP
    016-214 The FAX card was not installed or an error was detected when SW optional function was enabled.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Verify FAX Board PL 18.1 Item 9 is correctly installed, the error persists,
    3. Install a new FAX Board, REP 18.1.9.
  • Code: 016-234, 016-235
  • Description: XCP Error RAP
    016-234 Lack of memory causes the XCP to stop.
    016-235 Another internal error causes the XCP function to stop.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Start “Special Boot Mode” GP 15 and initiate “HDD Initialize Mode”. • Although there is no HDD option for this printer GP 15 “HDD Initialize Mode” is the procedure to initialize the eMMC Card.
    NOTE: After HHD Initialize, it may be necessary to verify the Device ID following dC132
  • Code: 016-242
  • Description: System GMT Clock Fail RAP
    016-242 System GMT clock fail.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Set the current date and time, the error persists,
    3. Install a new ESS Board REP 18.1.5 .
  • Code: 016-244
  • Description: Self-Signed Certificate Auto Update Fail RAP
    016-244 Self-sIgned certificate auto update failure.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Perform 2.6 Log and contact Support with the appropriate log files for further assistance.
  • Code: 016-310
  • Description: SSMM Job Log Full RAP
    016-310 A job log file was not retrieved from the external application (AWAS) and the number of files stored exceeded the specified value (280).
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4.
    2. Obtain the job log file from the external application (AWAS) via SSMI. a. Power down then power up the machine, GP 4, the error persists, b. Contact Supoort for further instruction
  • Code: 016-311, 016-315, 016-319, 016-354
  • Description: Scanner/IIT Errors RAP
    016-311:No Scanner that Should Be
    016-315:IIT Interface Fail
    016-319:Long Boot Diag IIT Interface Fail
    016-354:Cont IIT-Controller Comunication Fail
    Possible Parts Affected
    DADF ASSY PL 50.1 Item 1
    IIT ASSY PL 50.1 Item 2
    ESS Board PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP)
  • Troubleshooting Guides: Initial Action 1. Power down then power up the machine to check if the error recurs GP 4 . • 062-380 / 065-221/ 065-222/ 065-225 only: Clean the document glass and the white stripe before proceeding.
    1. Check the connection at the ESS Board and the IIT ASSY, verify P/J1370, P/J1374 and P/ J1372 are fully seated. a. Install a new IIT ASSY REP 50.1.2
    2. Check the connection at the ESS Board and the DADF ASSY, verify P/J1371 and P/ J1377 are fully seated. a. Install a new DADF ASSY REP 50.1.1 , the error persists,
    3. Install a new ESS Board REP 18.1.5(MFP) REP 18.5.5(SFP)
  • Code: 016-320
  • Description: Document Formatter Fatal Error RAP
    016-320 A software error was detected when documents were converted.
  • Troubleshooting Guides: Initial Actions
    Collect the detailed procedures below from the customer when a trouble occurred.
    1. In which mode the problem occur? (Copy/Scan/Print/Fax)
    2. What job was performed when the problem occurred?
    3. Check the job settings from the UI.
    4. Collect other information as much as possible to reproduce the error.
    • For Jobs that went through a network, also collect the output report and the network configuration.
    • For Print, also Obtain the PRN file of the Job if possible.
    1. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to Obtain the log, set NVM (700-530) to’0’ to perform log collection and return the NVM (700- 530) to’1’ after completing the procedure.
    2. Perform Hardware Diagnostic using the LONGDIAG MODE in the Special Booting Menu. (Refer to [2.8 Special Booting])
    3. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer to Firmware Version Upgrade GP 9 .)
    4. Turn the power off and on.
    5.The error persists after turning the power off and on GP 4, Obtain the log file using the log tool. Perform 2.6 Log RAP
    6. Turn off the Power GP 4, unplug the power cord for 2 minutes, then turn on the Power again GP 4 to perform the same operation where the error occurred.
    7. Verify the wire harness connections on each board are installed properly, then perform the same operation creating the error.
    8. Install a new ESS Board REP 18.1.2 (MFP), REP 18.5.2 (SFP) and perform the same operation where the error occurred, the error persists.
    9. Reinstall the original ESS Board and contact the Support Department for instructions.
  • Code: 016-321
  • Description: FAX Module Error RAP
    016-321 FAX related error at booting.
  • Troubleshooting Guides: Initial Actions
    Get the procedures for reproducing an error according to the operation that was performed when the error occurred.
    1. Check the job type: Send Mail, Receive Mail, Broadcast Send, Polling, or Folder Receipt.
    2. Check the job settings from the Panel.
    3. Check whether it is Speed Dial or Keypad Dial.
    4. Check which function was used: G3 or G4. • Collect other procedures as much as possible to reproduce the error.
    Perform the steps that follow:
    1. Verify the FAX Board PL 18.1 Item 9 and Fax Harness Assy PL 18.1 Item 10 connections are seated fully.
    2. Obtain the Fax-related reports (Protocol Monitor, Activity Report, Configuration Report, Scan / Fax Configuration, and Job History Report). • Depending on the situation, such as in the cases of Broadcast Send or Folder Receipt, Obtain the Speed Dial list or Stored Document list.
    3. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. (Refer Firmware Version Upgrade GP 9).
    4. Perform the same operation where the error occurred. • The error persists, replace the Front USB Harness Assy PL 18.1 Item 14 .
    5. Immediately after the error occurs, Obtain the log file using the log tool. Perform 2.6 Log RAP
    6. Install a new FAX Board REP 18.1.9 and perform the operation again, the error persists,
    7. Reinstall the original FAX Board and contact the Support for instructions.
  • Code: 016-323
  • Description: B-Formatter Fatal Error RAP
    016-323 Fatal error has occurred in the B-formatter task.
  • Troubleshooting Guides: Initial Actions
    Collect the detailed procedures below from the customer when a trouble occurred.
    1. In which mode the problem occur? (Copy/Scan/Print/Fax)
    2. What job was performed when the problem occurred?
    3. Check the job settings from the UI.
    4. Collect other information as much as possible to reproduce the error.
    • For Jobs that went through a network, also collect the output report and the network configuration.
    • For Print, also Obtain the PRN file of the Job if possible.
    Procedure
    1. Obtain the log file using the log tool. Perform 2.6 Log RAP • If there was a reboot after the error had occurred and hence was unable to Obtain the log, set NVM (700-530) to’0’ to perform log collection and return the NVM (700- 530) to’1’ after completing the procedure.
    2. Perform Hardware Diagnostic using the LONGDIAG MODE in the Special Booting Menu. (Refer to GP 15 Special Booting.)
    3. Check the version of Controller ROM. If it is not the latest, download and update to the latest software revision. Refer to Firmware Version Upgrade GP 9
    4. Turn the power off and on.
    5.The error persists after turning the power off and on GP 4, Obtain the log file using the log tool. Perform 2.6 Log RAP
    6. Turn off the Power GP 4, unplug the power cord for 2 minutes, then turn on the Power again GP 4 to perform the same operation where the error occurred.
    7. Verify the wire harness connections on each board are installed properly, then perform the same operation creating the error.
    8. Install a new ESS Board REP 18.1.2 (MFP), REP 18.5.2 (SFP) and perform the same operation where the error occurred, the error persists.
    9. Reinstall the original ESS Board and contact the Support Department for instructions.
  • Code: 016-326, 016-362, 016-607
  • Description: UI Cable Connection Fail RAP
    016-326: Cont-UI Cable Connection Fail The controller has detected a failure at its cable connection with the UI.
    016-362: Cont UI Fail-2
    016-607: Cont-UI Cable Connection Fail
    Possible Parts Affected
    CONSOLE ASSY UI AIO PL 1.1 Item 1
    CONSOLE ASSY UI SFP PL 1.2 Item 1
    HARNESS ASSY FRONT USB PL 18.1 Item 14
    ESS Board PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP)
  • Troubleshooting Guides: Perform the steps that follow: MFP
    1. Check the connection at the CONSOLE ASSY UI AIO and the ESS Board, verify P/J1352 is fully seated, the error persists,
    2. Install a new CONSOLE ASSY UI AIO REP 1.1.1
    3. Upgrade the Firmware GP 9.
    4. HARNESS ASSY FRONT USB PL 18.1 Item 14
    5. Install a new ESS Board REP 18.1.5
    Perform the steps that follow: SFP
    1. Check the connection at the CONSOLE ASSY UI SFP and the ESS Board, verify P/J1352 is fully seated, the error persists,
    2. Install a new CONSOLE ASSY UI SFP REP 1.2.1
    3. Upgrade the Firmware GP 9.
    4. Install a new ESS Board REP 18.5.5 (SFP)
  • Code: 016-328
  • Description: Connection Fail RAP
    016-328 The controller has detected a failure at its cable connection with the MCU.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Verify all connectors between the ESS Board and the MCU Board, and all surface mounted modules such as the eMMC Card, are fully seated.
    3. Install a new ESS-PWR-C Harness Assy PL 18.4 Item 1 (MFP) PL 18.8 Item 1 (SFP).
  • Code: 016-330, 016-331, 016-332
  • Description: Cont System Memory Fail RAP
    016-330 Cont system memory diagnostic fail 1.
    016-331 Cont system memory diagnostic fail 2.
    016-332 Cont system memory diagnostic fail 3.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Verify all connectors between the ESS Board and the MCU Board, and all surface mounted modules such as the eMMC Card, are fully seated.
    3. Install a new ESS Board, REP 18.1.5 (MFP), REP 18.5.5 (SFP).
  • Code: 016-342, 016-343, 016-345
  • Description: Controller Fail RAP
    016-342 Cont RTC diagnostic fail.
    016-343 Long boot diag timer fail.
    016-345 Cont NVM diagnostic fail.
  • Troubleshooting Guides: 1. Power down then power up the machine, GP 4 .
    2. Verify the time and date are set correctly for the customer location.
    3. Reload or update the Firmware, GP 9 , the error persists, GP 9 , the error persists,
    4. Install a new ESS Board REP 18.1.5 (MFP), REP 18.5.5 (SFP).
    NOTE: RTC is set as GMT; ‘Local Time’ setting will be separately done by customer. Case1: If ‘Local Time’ is not set by customers, they need to set as initial setting for ‘Local Time’. Case2: If ‘Local Time’ has been set by customers already, they don’t need to set it again.
  • Code: 058-310, 058-311, 058-315, 058-316
  • Description: FUSING ASSY RAP
    058-310: Fusing Ep U4 Notrdy Nc Fail
    058-311: Fusing Ep U4 Notrdy Sts Fail)
    058-315: FUSING ASSY HR STS Center Broken Fail
    058-316: Fusing Unit HB STS Center Low Temperature Fail
    059-315: FUSING ASSY HR STS Center Over Temperature Fail
    Possible Parts Affected
    • FUSING ASSY PL 7.1 Item 1
    • Fuser Harness (DC) (J270-J272, J273) PL 18.3 Item 2 (MFP) PL 18.7 Item 2 (SFP)
    • Fuser Harness (AC) 110VAC (J283-P275) PL 18.3 Item 3A (MFP) PL 18.7 Item 3A (SFP)
    • Fuser Harness (AC) 220VAC(J283-P275) PL 18.3 Item 3B (MFP) PL 18.7 Item 3B (SFP)
    • LV MCU Harness Assy (J280-J284) PL 18.4 Item 5 (MFP) PL 18.8 Item 5(SFP)
    • LVPS Board PL 18.1 Item 16 (MFP), PL 18.5 Item 16 (SFP)
    • MCU Board, PL 18.1 Item 1 (MFP), PL 18.5 Item 1 (SFP)
  • Troubleshooting Guides: 1. Verify the FUSING ASSY and the drawer connector of the printer are installed properly (without a bent pin, or any foreign or burnt objects, etc.).
    2. Check the connection between the FUSING ASSY and the MCU Board and FUSING ASSY and LVPS Board (P/J283, P/J275, P/J270, and P/J273) are fully seated. (Refer to Figure 1).
    3. Check the connection between the LVPS Board and the MCU Board (P/J284, P/J280) are fully seated.
    4. Check the continuity between the Fuser Harness (AC) 110VAC in each cable of P/ J283<=>P/J275. • Install a new Fuser Harness (AC) 110VAC.
    5. Check the continuity between the LV MCU Harness Assy (J280-J284) in each cable of P/ J284<=>P/J280. • Install a new LV MCU HARNESS ASSY PL 18.4 Item 5.
    6. Install a new MCU Board, REP 18.1.1 (MFP), REP 18.5.1 (SFP)
    7. Install a new LVPS Board REP 18.1.16 (MFP) REP 18.5.16 (SFP)
  • Code: 059-315, 059-326, 099-396-399
  • Description: FUSING ASSY RAP
    059-315: FUSING ASSY HR STS Center Over Temperature Fail
    059-326: FUSING ASSY HR STS Disconnection Fail
    099-396: Fusing Ep U4 Noheat Center Fail
    099-397: Fusing Ep U4 Slowheat Center Fail
    099-398: Fusing Ep U4 Fastheat Center Fail
    099-399: Fusing Ep U4 Under Side Fail
    Possible Parts Affected
    • FUSING ASSY PL 7.1 Item 1
    • Fuser Harness (DC) (J270-J272, J273) PL 18.3 Item 2 (MFP) PL 18.7 Item 2 (SFP)
    • Fuser Harness (AC) 110VAC (J283-P275) PL 18.3 Item 3A (MFP) PL 18.7 Item 3A (SFP)
    • Fuser Harness (AC) 220VAC(J283-P275) PL 18.3 Item 3B (MFP) PL 18.7 Item 3B (SFP)
    • LV MCU Harness Assy (J280-J284) PL 18.4 Item 5 (MFP) PL 18.8 Item 5(SFP)
    • LVPS Board PL 18.1 Item 16 (MFP), PL 18.5 Item 16 (SFP)
    • MCU Board, PL 18.1 Item 1 (MFP), PL 18.5 Item 1 (SFP)
  • Troubleshooting Guides: 1. Verify the FUSING ASSY and the drawer connector of the printer are installed properly (without a bent pin, or any foreign or burnt objects, etc.).
    2. Check the connection between the FUSING ASSY and the MCU Board and FUSING ASSY and LVPS Board (P/J283, P/J275, P/J270, and P/J273) are fully seated. (Refer to Figure 1).
    3. Check the connection between the LVPS Board and the MCU Board (P/J284, P/J280) are fully seated.
    4. Check the continuity between the Fuser Harness (AC) 110VAC in each cable of P/ J283<=>P/J275. • Install a new Fuser Harness (AC) 110VAC.
    5. Check the continuity between the LV MCU Harness Assy (J280-J284) in each cable of P/ J284<=>P/J280. • Install a new LV MCU HARNESS ASSY PL 18.4 Item 5.
    6. Install a new MCU Board, REP 18.1.1 (MFP), REP 18.5.1 (SFP)
    7. Install a new LVPS Board REP 18.1.16 (MFP) REP 18.5.16 (SFP)
  • Code: 062-277, 062-311, 062-316, 062-360, 062-371, 062-380
  • Description: Scanner/IIT Errors RAP
    062-277:IISS-DADF Communication Fail
    062-311:IISS LOGIC Fail
    062-316:DADF Motor Fail
    062-360:CRG Position Fail
    062-371:Lamp Illumination Fail
    062-380:AGC Fail
    Possible Parts Affected
    DADF ASSY PL 50.1 Item 1
    IIT ASSY PL 50.1 Item 2
    ESS Board PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP)
  • Troubleshooting Guides: Initial Action 1. Power down then power up the machine to check if the error recurs GP 4 . • 062-380 / 065-221/ 065-222/ 065-225 only: Clean the document glass and the white stripe before proceeding.
    1. Check the connection at the ESS Board and the IIT ASSY, verify P/J1370, P/J1374 and P/ J1372 are fully seated. a. Install a new IIT ASSY REP 50.1.2
    2. Check the connection at the ESS Board and the DADF ASSY, verify P/J1371 and P/ J1377 are fully seated. a. Install a new DADF ASSY REP 50.1.1 , the error persists,
    3. Install a new ESS Board REP 18.1.5(MFP) REP 18.5.5(SFP)
  • Code: 062-386, 062-389, 062-393, 062-396
  • Description: Scanner/IIT Errors RAP
    062-386:AOC Fail
    062-389:CRG Over Run Fail
    062-393:CCD PWBA Sync Signal Fail
    062-396:CIS Cable Connection Fail
    Possible Parts Affected
    DADF ASSY PL 50.1 Item 1
    IIT ASSY PL 50.1 Item 2
    ESS Board PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP)
  • Troubleshooting Guides: Initial Action 1. Power down then power up the machine to check if the error recurs GP 4 . • 062-380 / 065-221/ 065-222/ 065-225 only: Clean the document glass and the white stripe before proceeding.
    1. Check the connection at the ESS Board and the IIT ASSY, verify P/J1370, P/J1374 and P/ J1372 are fully seated. a. Install a new IIT ASSY REP 50.1.2
    2. Check the connection at the ESS Board and the DADF ASSY, verify P/J1371 and P/ J1377 are fully seated. a. Install a new DADF ASSY REP 50.1.1 , the error persists,
    3. Install a new ESS Board REP 18.1.5(MFP) REP 18.5.5(SFP)
  • Code: 065-221, 065-222, 065-223, 065-224, 065-225
  • Description: Scanner/IIT Errors RAP
    065-221:CIS AGC Fail
    065-222:CIS AOC Fail
    065-223:CIS Connection Fail
    065-224:CIS Device Fail
    065-225:CIS FAIL
    Possible Parts Affected
    DADF ASSY PL 50.1 Item 1
    IIT ASSY PL 50.1 Item 2
    ESS Board PL 18.1 Item 5 (MFP), PL 18.5 Item 5 (SFP)
  • Troubleshooting Guides: Initial Action 1. Power down then power up the machine to check if the error recurs GP 4 . • 062-380 / 065-221/ 065-222/ 065-225 only: Clean the document glass and the white stripe before proceeding.
    1. Check the connection at the ESS Board and the IIT ASSY, verify P/J1370, P/J1374 and P/ J1372 are fully seated. a. Install a new IIT ASSY REP 50.1.2
    2. Check the connection at the ESS Board and the DADF ASSY, verify P/J1371 and P/ J1377 are fully seated. a. Install a new DADF ASSY REP 50.1.1 , the error persists,
    3. Install a new ESS Board REP 18.1.5(MFP) REP 18.5.5(SFP)



– Get more error code list with quick guide to fix printer product, click here


– About get help with reseting Epson inkpad or others, click here

– Get more information about Epson XP 15000 troubleshooting, click here

Xerox printer reset software introduction:

Notes before resetting Xerox printer:

– Identify accurate version, serial and crum of Xerox printer.
– How to get Xerox printer model info: Click Here
– Before you continue with the reprogramming of the firmware, please make sure that the device is installed on your computer.
It is very important that under no circumstances should you remove the chip from the cartridge while reprogramming the firmware. After you have succesfully reprogrammed the printer, remove the chip from the cartridge and store it somewhere safely (the chip – a key). In all cartridges which you are going to use in the printer, the chip has to be either removed or sealed. If you have accidently inserted a new cartridge without removing the chip, the device will be blocked. In order to unblock it, you can use the stored chip as a key which help you to unblock the printer.
– And make sure that any other devices (except mouse and keyboard), which are connected to your computer via USB or LPT ports are disconnected. It’s preferable that the computer is connected to the “UPS” (uninterruptible power source) device, because if during the reprogramming process the electricity source has any interruptions, then the reprogramming will be carried out with an error, which makes the device unable to work.
– This firmware will be installed directly to your printer. Before opening firmare link make sure that printer is turned on and connected to your computer and printer drivers are installed correctly.
Be aware that with the reprogramming of the firmware the manufacturer’s warranty goes lost!!

How To Run Firmware Fix Xerox printer

1. Connect the printer to the computer and turn it on.
2. Wait until the printer is ready for work.
3. Drag and drop *.hd to usbprns2.exe file.

Run Firmware Fix Xerox B205

4. The reprogramming process starts automatically.
5. Wait until the printer reprograms (10-20 minute) and restarts.
6. After that the reprogramming process is finished, restart the printer.
– Fix Xerox B205 Toner Empty Error, click here

Contact us to get support with Xerox WorkCentre 6515 Error case

Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/
Or click here to get more ways.

Понравилась статья? Поделить с друзьями:
  • Ошибка 0x0000007b gta 5
  • Ошибка 0x0000007b 0xfffff880009a97e8
  • Ошибка 0x000000709 при установке принтера
  • Ошибка 0x0000007a kernel data inpage error
  • Ошибка 0x00000077 принтер windows 10