Ошибка 062 380 xerox 6515

Most business at Xerox is likely to go well and generate sufficient profit. A reason for Xerox not to respond to the minority experiencing technical problems.

I bought the Xerox Workstation at the time because the brand had a good name. The reason I chose a laser printer was because I printed too little and my ink jet printer dried up every year. A laser printer does not have this problem.

After 2 years and 2 months I got the well-known 062-380 problem. I first tried to get help from the shop for repair. When the store wouldn’t help me, I asked Xerox directly for help. Xerox wanted to repair the workstation, but it cost twice the price of a new machine. Of course I’m not crazy and I didn’t do it… I’m really not mentally disturbed.

The printer itself works great. I’m still working on the supplied toner cartridges. To solve my problem I bought a small inexpensive printer/scanner from HP so that I can continue scanning.

My problem has been solved with this and as written before: NEVER AGAIN A XEROX IN MY HOUSE. Xerox is not going to help simple private users. The company is too big for that. We are not important.

  1. 10-22-2021


    #1

    UNICORNico is offline


    Senior Tech

    250+ Posts

    UNICORNico's Avatar


    Rep Power
    14

    Question WorkCenter 6515, error 062-380

    Hello Companions.

    First to say that I do not handle this brand (I am a ricoh technician/distributor), it is a request from a customer, who has a Xerox WorkCenter 6515, and asks my technical department if we can solve this problem.

    The device throws this fault code «062-380» so it does not allow you to operate, someone can lend a hand. Thank you.

    ​Apologies for my English, it’s not my mother tongue and I’m helping the translator.
    ALL WILL BE WELL


  2. 10-22-2021


    #2

    Re: WorkCenter 6515, error 062-380

    Insufficient lamp brightness was detected when performing AGC.


  3. 10-25-2021


    #3

    UNICORNico is offline


    Senior Tech

    250+ Posts

    UNICORNico's Avatar


    Rep Power
    14

    Re: WorkCenter 6515, error 062-380

    Quote Originally Posted by adriansto
    View Post

    Se detect� un brillo insuficiente de la l�mpara al realizar AGC.

    I understand that this failure may be due to the explorer’s lamp being dirty, or it being melted/broken.

    True? In the case of dirt, it should be possible to clean both the lamp and the mirrors of the explorer.

    You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.

    Last edited by UNICORNico; 10-25-2021 at 04:09 PM.

    ​Apologies for my English, it’s not my mother tongue and I’m helping the translator.
    ALL WILL BE WELL


  4. 10-25-2021


    #4

    Re: WorkCenter 6515, error 062-380

    [QUOTE=UNICORNico;1945975]

    Quote Originally Posted by adriansto
    View Post

    You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.

    It is about scanner lamp. Under the scanner glass it is white band ( label ) Check that label is clean, check if the scanner mirrors are clean. All of these works on AGC = Automatic Gain Control


  5. 10-25-2021


    #5

    sarathc is offline


    Junior Member


    Rep Power
    0

    Re: WorkCenter 6515, error 062-380

    You have to replace the IIT assy , ie the scanner assy below is description of the fault ,

    062-311, 313, 321, 360, 371, 380, 386, 389, 393, 396-398 IIT
    Fail RAP
    062-311 Error detected in IISS software.
    062-313 Unexecutable Scan command error.
    062-321 Unexecutable Scan command error.
    062-360 Carriage home position error is detected.
    062-371 IIT failure Lamp error is detected.
    062-380 Insufficient lamp brightness was detected when performing AGC.
    062-386 During AOC (darkness adjustment), detected CCD output error.
    062-389 Overrunning of CRG was detected.
    062-393 CISASIC communication error is detected.
    062-396 Connection problem of CIS flat cable was detected.
    062-397 Connection problem of ESS Video cable was detected.
    062-398 Connection problem of ESS I/O cable was detected.
    Procedure
    WARNING
    Ensure that the electricity to the machine is switched off while performing tasks that do
    not need electricity. Refer to [GP 4]. Disconnect the power cord. Electricity can cause
    death or injury. Moving parts can cause injury.
    1. Power the machine down then back up, [GP 4], the error persists,
    2. Clean the scanner platen and the white stripe, [GP 34], the error persists,
    3. Install a new IIT Assembly, [REP 50.1.2], the error persists,
    4. Install a new DADF Assembly, [REP 50.1.1],


Модератор: vetal

















  • Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»

    kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4

    5
    5929

    3100
    Перейти к последнему сообщению
    Пн ноя 18, 2019 8:24 pm
  • Xerox WC 3119: «Замятие 1»

    kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4

    22
    40003

    kokubenko
    Перейти к последнему сообщению
    Ср ноя 23, 2011 4:47 pm
  • Xerox WC3220 — Ложное замятие бумаги, Замятие 0

    Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4

    25
    11961

    Romeo
    Перейти к последнему сообщению
    Пн окт 12, 2020 7:13 pm
  • «Неисправность» финишера Xerox 7556

    v1684 в форуме Принтеры, МФУ, копиры формата A3

    21
    13712

    v1684
    Перейти к последнему сообщению
    Ср сен 19, 2018 4:44 pm
  • прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил

    Володья в форуме Принтеры, МФУ, факсы, копиры формата A4

    8
    13148

    Володья
    Перейти к последнему сообщению
    Сб апр 30, 2011 8:05 am

Вернуться в Принтеры, МФУ, факсы, копиры формата A4

Кто сейчас на форуме

Сейчас этот форум просматривают: Дмитрий Клюшников и гости: 63

Most business at Xerox is likely to go well and generate sufficient profit. A reason for Xerox not to respond to the minority experiencing technical problems.

I bought the Xerox Workstation at the time because the brand had a good name. The reason I chose a laser printer was because I printed too little and my ink jet printer dried up every year. A laser printer does not have this problem.

After 2 years and 2 months I got the well-known 062-380 problem. I first tried to get help from the shop for repair. When the store wouldn’t help me, I asked Xerox directly for help. Xerox wanted to repair the workstation, but it cost twice the price of a new machine. Of course I’m not crazy and I didn’t do it… I’m really not mentally disturbed.

The printer itself works great. I’m still working on the supplied toner cartridges. To solve my problem I bought a small inexpensive printer/scanner from HP so that I can continue scanning.

My problem has been solved with this and as written before: NEVER AGAIN A XEROX IN MY HOUSE. Xerox is not going to help simple private users. The company is too big for that. We are not important.

  1. 10-22-2021

    #1

    Question WorkCenter 6515, error 062-380

    Hello Companions.

    First to say that I do not handle this brand (I am a ricoh technician/distributor), it is a request from a customer, who has a Xerox WorkCenter 6515, and asks my technical department if we can solve this problem.

    The device throws this fault code «062-380» so it does not allow you to operate, someone can lend a hand. Thank you.

    ​Apologies for my English, it’s not my mother tongue and I’m helping the translator.
    ALL WILL BE WELL


  2. 10-22-2021

    #2

    Re: WorkCenter 6515, error 062-380

    Insufficient lamp brightness was detected when performing AGC.


  3. 10-25-2021

    #3

    Re: WorkCenter 6515, error 062-380

    Quote Originally Posted by adriansto
    View Post

    Se detect� un brillo insuficiente de la l�mpara al realizar AGC.

    I understand that this failure may be due to the explorer’s lamp being dirty, or it being melted/broken.

    True? In the case of dirt, it should be possible to clean both the lamp and the mirrors of the explorer.

    You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.

    Last edited by UNICORNico; 10-25-2021 at 04:09 PM.

    ​Apologies for my English, it’s not my mother tongue and I’m helping the translator.
    ALL WILL BE WELL


  4. 10-25-2021

    #4

    Re: WorkCenter 6515, error 062-380

    [QUOTE=UNICORNico;1945975]

    Quote Originally Posted by adriansto
    View Post

    You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.

    It is about scanner lamp. Under the scanner glass it is white band ( label ) Check that label is clean, check if the scanner mirrors are clean. All of these works on AGC = Automatic Gain Control


  5. 10-25-2021

    #5

    sarathc is offline


    Junior Member


    Rep Power
    0

    Re: WorkCenter 6515, error 062-380

    You have to replace the IIT assy , ie the scanner assy below is description of the fault ,

    062-311, 313, 321, 360, 371, 380, 386, 389, 393, 396-398 IIT
    Fail RAP
    062-311 Error detected in IISS software.
    062-313 Unexecutable Scan command error.
    062-321 Unexecutable Scan command error.
    062-360 Carriage home position error is detected.
    062-371 IIT failure Lamp error is detected.
    062-380 Insufficient lamp brightness was detected when performing AGC.
    062-386 During AOC (darkness adjustment), detected CCD output error.
    062-389 Overrunning of CRG was detected.
    062-393 CISASIC communication error is detected.
    062-396 Connection problem of CIS flat cable was detected.
    062-397 Connection problem of ESS Video cable was detected.
    062-398 Connection problem of ESS I/O cable was detected.
    Procedure
    WARNING
    Ensure that the electricity to the machine is switched off while performing tasks that do
    not need electricity. Refer to [GP 4]. Disconnect the power cord. Electricity can cause
    death or injury. Moving parts can cause injury.
    1. Power the machine down then back up, [GP 4], the error persists,
    2. Clean the scanner platen and the white stripe, [GP 34], the error persists,
    3. Install a new IIT Assembly, [REP 50.1.2], the error persists,
    4. Install a new DADF Assembly, [REP 50.1.1],


Модератор: vetal

















  • Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»

    kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4

    5
    5744

    3100
    Перейти к последнему сообщению
    Пн ноя 18, 2019 8:24 pm
  • Xerox WC 3119: «Замятие 1»

    kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4

    22
    39617

    kokubenko
    Перейти к последнему сообщению
    Ср ноя 23, 2011 4:47 pm
  • Xerox 3428 «Установите Картридж»

    Roller-ch в форуме Принтеры, МФУ, факсы, копиры формата A4

    6
    9606

    SeMi
    Перейти к последнему сообщению
    Сб авг 27, 2011 6:42 pm
  • Xerox 3315 «слетела» FIX прошивка

    tekknik в форуме Принтеры, МФУ, факсы, копиры формата A4

    7
    7298

    tekknik
    Перейти к последнему сообщению
    Пн июн 10, 2019 4:22 am
  • Xerox WC3220 — Ложное замятие бумаги, Замятие 0

    Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4

    25
    11394

    Romeo
    Перейти к последнему сообщению
    Пн окт 12, 2020 7:13 pm

Вернуться в Принтеры, МФУ, факсы, копиры формата A4

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 32

Go to printers

r/printers

Inkjets, lasers, thermal, commercial and industrial printers.

We make printers suck less by promoting printer maintenance, troubleshooting and providing accurate recommendations.




Online

Xerox Workcentre 6515 error 062-380 & 062-386

Hey I have this printer and got both of these error codes. From my research it appears to be something with the scanner, possibly a lose connector or bad sensor.

From reading other posts it sounds like I may be able to order a new scanner module.

Also if anyone has a link to a service manual that tells me how to replace it, maybe I could use that to check for a lose connection.

12.12.2011

Вопрос:

Здравствуйте. Есть аппарат Xerox WorkCentre Pro 128.
Последнее время часто стала появляться ошибка 062-380, помогает перезагрузка (по питанию), но иногда это необходимо сделать раз 5-10. Ошибка появляется в основном, когда МФУ выходит из режима safemode. Что это может быть и как с этим бороться?

p.s. зеркала визуально чистые

Ответ:

062-380 — неисправность в блоке сканера. Нужно проверить лампу, объектив, зеркало. Обратитесь в сервисный центр.

Задайте свой вопрос

Чтобы задать вопрос, Вам необходимо авторизоваться

  • Go Back
  • Blog
  • Xerox WorkCentre 6515 Versalink C405 C505 C605 Fault Code 062-380: Insufficient Lamp Brightness was Detected When Performing AGC

Xerox WorkCentre 6515 Versalink C405 C505 C605 Fault Code 062-380: Insufficient Lamp Brightness was Detected When Performing AGC

Xerox WorkCentre 6515 Versalink C405 C505 C605 Fault Code 062-380: Insufficient Lamp Brightness was Detected When Performing AGC

We’ve been receiving a lot of emails and requests to help out with the error codes 062-380 & 062-386 AOC Failure. CCD output error detected during AOC darkness adjustment for the Xerox WorkCentre 6515 Versalink C405 C505 C605 machines.

Firstly, try the procedure below, it could just be dirt build up on the scanner.
https://www.support.xerox.com/en-us/article/en/2056422

The problem relates to the scanner head inside the scanner assembly under the platen glass. As there’s 2 inside these machines, one in the scanner and the other in the document feeder, it is possible to change these over to get the scanner to work once again. It does mean that the DADF scanner will no longer function.

The part number is DL620-01UHG-B.

Понравилась статья? Поделить с друзьями:
  • Ошибка 062 360 xerox
  • Ошибка 0642 киа
  • Ошибка 061а61 рено логан 2
  • Ошибка 064116 ларгус
  • Ошибка 061b00 мерседес cla 200