Nice 3000 monarch коды ошибок

Monarch NICE3000 User Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

loading

Related Manuals for Monarch NICE3000

Summary of Contents for Monarch NICE3000

  • Page 2: Table Of Contents

    3.2 Use of the LED Operation Panel ………………18 3.3 CTB Board ……………………20 3.4 Display Board (MCTC-HCB)……………….22 3.5 CCB Board ……………………29 Chapter 4 Use of the NICE3000 …………….32 4.1 Wiring Diagrams Under Default Parameter Settings …………32 4.2 Description of Shaft Signals ……………….33 4.3 Typical Commissioning ………………..35 Chapter 5 Function Code Table …………….

  • Page 4
    Overview…
  • Page 5: Chapter 1 Overview

    Brief NICE3000 Instruction Manual Chapter 1 Overview To facilitate the users who use the NICE3000 control system for the first time to understand how to commission the control system as quickly as possible, this manual briefly describes the specifications, wiring, common parameter setting, and common commissioning of the NICE3000.

  • Page 6
    Product Information…
  • Page 7: Chapter 2 Product Information

    2.2 Mounting Dimensions The NICE3000 controller has three sizes: SIZE-C, SIZE-D, and SIZE-E, as shown in the following figure. SIZE-F is a customized model with different appearances but the same installation mode. The following figure and table show the appearance and physical dimensions of the NICE3000 controller.

  • Page 8
    45 kW Note 1. The NICE3000 controller of other power ratings, such as above 45 kW is rarely applied in the elevator, and therefore, specifications are not provided here. For future detail on the options and availability, please contact Monarch.
  • Page 9: Electrical Specifications

    Product Information Brief NICE3000 Instruction Manual 2.3 Electrical Specifications Table 2-2 NICE3000 models and electrical specifications Power Input Current Output Motor Power System Model Capacity (kVA) Current (A) (kW) AC supply voltage: single-phase 220 V, range: –15% to 20% NICE-L-A/B-2002 13.2…

  • Page 10
    3. Select the proper controller output current based on the motor rated current. Ensure that the controller output current is equal to or greater than the motor rated current. Table 2-3 Technical specifications of the NICE3000 Item Specification…
  • Page 11
    Product Information Brief NICE3000 Instruction Manual Item Specification Providing 57 protections such as: • Power-on short circuit detection • Protection at power phase loss and output phase loss Fault protection • Over-current protection • Door machine fault protection • Encoder protection •…
  • Page 12: Braking Resistor

    Brief NICE3000 Instruction Manual Product Information 2.4 Braking Resistor The models of 30 kW or below have a built-in braking unit, and you only need to connect an external braking resistor between PB and + terminals. For models above 30 kW, you need to install a braking unit and a braking resistor externally.

  • Page 13: Terminal Descriptions

    ER OK COPHOP MDBUS CN12 RJ45 MCTC-MCB The NICE3000 provides a keypad with three keys and three 7-segment LEDs for display, and five LED status indicators. The NICE3000 also supports the external LED operation panel. Table 2-6 Terminal description and specifications…

  • Page 14
    Brief NICE3000 Instruction Manual Product Information Mark Code Terminal Name Function Description Normally-open (NO), maximum current Y1/M1 to Y6/ Relay output and voltage rating: 5A, 250 VAC. The functions are set in F5-26 to F5-31. 15V/PGM/ Encoder interface for Connecting the incremental encoder…
  • Page 16
    Component Description…
  • Page 17: Chapter 3 Component Description

    Component Description Brief NICE3000 Instruction Manual Chapter 3 Component Description 3.1 Onboard Keypad Description The onboard keypad consists of three 7-segment LEDs and three buttons. You can query information about the controller and enter simple commands on the keypad. The following figure shows the appearance of the keypad.

  • Page 18
    Brief NICE3000 Instruction Manual Component Description The function code groups displayed on the keypad are described as follows: 1. F0: display of floor and running direction The F0 menu is displayed on the keypad by default upon power-on. The first 7-segment LED indicates the running direction, while the last two 7-segment LEDs indicate the current floor of the elevator.
  • Page 19: Use Of The Led Operation Panel

    0 automatically. 3.2 Use of the LED Operation Panel The LED operation panel is connected to the RJ45 interface of the NICE3000 controller by means of an 8-core flat cable. You can modify the function parameters, monitor the working status, and run or stop the NICE3000 controller by using the LED operation panel.

  • Page 20
    Brief NICE3000 Instruction Manual Component Description Unit Indicators ■ indicates OFF, and indicates ON. Hz: unit of frequency A: unit of current V: unit of voltage RPM: unit of rotational speed %: percentage Keys on the Operation Panel ■ Table 3-1 Keys on the operation panel…
  • Page 21: Ctb Board

    3.3 CTB Board The car top board (MCTC-CTB) is the elevator car control board of the NICE3000 controller. It consists of eight DI terminals, one AI terminal, and nine relay output terminals. The CTB can communicate with the CCB and HCB. The following figure shows the structure and size of the CTB.

  • Page 22
    Brief NICE3000 Instruction Manual Component Description Type Terminal Name Description 24 VDC power supply to the +24V/COM 24 V power supply (communication Modbus with the HCB) MOD+/MOD- Communication with the HCB communication CN6 (AI) Ai-M Load cell signal input 0–10 VDC…
  • Page 23: Display Board (Mctc-Hcb)

    floor and running direction for the hall. This board can also be used as car display board. Monarch provides many types of display boards. The following describes only a few common types. If you need other types, please contact Monarch.

  • Page 24
    Brief NICE3000 Instruction Manual Component Description Figure 3-5 Appearance of HCB-H Figure 3-6 Size of HCB-H 22.9 mm 4.2 mm Φ MCTC-HCB-H DOWN 34.3 mm 56.0 mm 22.5 mm 70.0 mm — 23 -…
  • Page 25
    Component Description Brief NICE3000 Instruction Manual The following table describes the input and output terminals. Table 3-4 Input and output terminals of HCB-H Terminal Name Function Interface for the elevator locking switch and up arrival indicator Pins 2 and 3 are for switch input. Pin 1 and 4 are power supply for the up arrival indicator.
  • Page 26
    Brief NICE3000 Instruction Manual Component Description Figure 3-8 Size of HCB-R1 3.5 mm Φ 22.8 mm MCTC-HCB-R1 6.7 mm 56.0 mm UP DOWN ST XF 10 mm 70 mm The following table describes the input and output terminals. Table 3-5 Input and output terminals of HCB-R1…
  • Page 27
    Component Description Brief NICE3000 Instruction Manual 3.4.3 HCB-D2 (Ultrathin Segment LED Display Board) The following figures show the appearance and size of HCB-D2. Figure 3-9 Appearance of HCB-D2 Figure 3-10 Size of HCB-D2 3.5 mm Φ 49 mm 56.0 mm UP DOWN ST XF 70.0 mm…
  • Page 28
    Brief NICE3000 Instruction Manual Component Description The following table describes the input and output terminals. Table 3-6 Input and output terminals of HCB-D2 Terminal Name Function Interface for the up call button and indicator Pins 2 and 3 are for up call input. Pins 1 and 4 are power supply for the up call indicator.
  • Page 29
    Component Description Brief NICE3000 Instruction Manual Figure 3-12 Size of HCB-U1 3-5.5 mm 4.5 mm Φ 53.0 mm 60.0 mm 9.4 mm 79.2 mm 16.9 mm The following table describes the input and output terminals. Table 3-7 Input and output terminals of HCB-U1…
  • Page 30: Ccb Board

    Brief NICE3000 Instruction Manual Component Description 3.5 CCB Board The car call board (MCTC-CCB) is another interface between users and the control system. Each CCB comprises 24 inputs and 22 outputs, including 16 floor buttons and 8 functional signals. The CCB mainly collects button calls and outputs signals of the button call indicators.

  • Page 31
    Component Description Brief NICE3000 Instruction Manual The following table describes the input and output terminals. Table 3-8 Input and output terminals of the CCB Interface Pins 2 and 3 Pins 1 and 4 Remarks Floor 1 button input Floor 1 display output…
  • Page 32
    Use of the NICE3000…
  • Page 33: Chapter 4 Use Of The Nice3000

    Chapter 4 Use of the NICE3000 4.1 Wiring Diagrams Under Default Parameter Settings 4.1.1 Electric Wiring of the NICE3000 The following figure shows the electric wiring diagram of the NICE3000. Figure 4-1 Electric wiring diagram of the NICE3000 24 V…

  • Page 34: Description Of Shaft Signals

    Brief NICE3000 Instruction Manual Use of the NICE3000 Note The above wiring diagram shows the default I/O function setting of group F5. The braking resistor is connected to PB and +. 4.1.2 Recommended CTB Wiring and Parameter Setting The following wiring diagram shows the default function setting of the CTB. You can change the input polarity (NO/NC) of the CTB terminals in F5-25.

  • Page 35
    4.2.3 Leveling Switch The NICE3000 system allows the use of 1 to 3 leveling switches. If only one leveling sensor is used, the corresponding function code which is used for input of leveling signal is allocated with function 03 (NO input of door zone signal).
  • Page 36: Typical Commissioning

    You need to add two re-leveling switches if applying the door pre-open function. In this case, you need to increase the length of the flag properly. For details on the door pre-open module, contact Monarch or local agent for more information. 4.3 Typical Commissioning 4.3.1 Check Before Commissioning…

  • Page 37
    Use of the NICE3000 Brief NICE3000 Instruction Manual R, S, T, U, V, W Input and output terminals of the controller and power supply for switches Brake power coils and wiring terminals of the braking resistor Nodes of various control signals…
  • Page 38
    4.3.2 Commissioning at Inspection Speed To implement accurate control on the motor, motor auto-tuning must be performed before the use of the NICE3000. Ensure that the installation and wiring satisfy the safety requirements and technical specifications before the auto-tuning. No-load Auto-tuning ■…
  • Page 39
    Use of the NICE3000 Brief NICE3000 Instruction Manual Then, set F1-12 (Encoder lines per revolution) based on the encoder nameplate. Remove the load from the motor completely. Set F1-11 to 2 (No-load auto-tuning). «TUNE» is displayed on the operation panel. Release the brake manually and press on the operation panel.
  • Page 40
    Brief NICE3000 Instruction Manual Use of the NICE3000 • 0: SIN/COS encoder • 1: UVW encoder F1-12 (Encoder lines per revolution) If applying the Heidenhain ECN 1313 or 413 encoder with the MD32PG5 card, set F1- 00 to 0. Enter the motor nameplate parameters correctly.
  • Page 41
    Use of the NICE3000 Brief NICE3000 Instruction Manual To perform with-load auto-tuning for asynchronous motor, do as follows: Set F0-01 (Command source selection) to 0 (Operation panel control) and press STOP on the operation panel to reset the current faults.
  • Page 42
    Brief NICE3000 Instruction Manual Use of the NICE3000 To perform with-load auto-tuning for PMSM, do as follows: Check the motor power cables and encoder wiring. Ensure that the motor’s UVW power cables are connected to the controller’s UVW terminals properly, and the encoder’s AB, UVW or CDZ signal cables are connected to the AB, UVW or CDZ terminals of the PG card properly.
  • Page 43
    Use of the NICE3000 Brief NICE3000 Instruction Manual Note After the motor auto-tuning is complete, the system prohibits inspection running for 8s and saves parameters during the time. 4.3.3 Summary of Commissioning at Inspection Speed Asynchronous Motor Auto-tuning Process ■…
  • Page 44
    Brief NICE3000 Instruction Manual Use of the NICE3000 PMSM Auto-tuning Process ■ Figure 4-4 Auto-tuning process of the PMSM Set F0-01 to 1 to restore Set F0-01 to 0 (No-load tuning ) distance control . or 1 (With-load tuning ) Resume the rope .
  • Page 45
    (F0-00 = 1, F0-01 = 1). 4. The top floor number (F6-00) and bottom floor number (F6-01) are set correctly. 5. The NICE3000 system is not in the fault alarm state. If there is a fault at the moment, STOP press to reset the fault.
  • Page 46
    Brief NICE3000 Instruction Manual Use of the NICE3000 For a faster system response, increase the proportional gain and reduce the integral gain. Be aware that a fast system response causes system oscillation. Figure 4-5 Relationship between switchover frequencies PI regulation…
  • Page 47
    Use of the NICE3000 Brief NICE3000 Instruction Manual Function Parameter Setting Range Default Description Code Name It specifies the time required from when the system outputs the open signal to when the Brake release 0.200s F3-19 0.000–1.000s brake is completely released.
  • Page 48
    Brief NICE3000 Instruction Manual Use of the NICE3000 Function Parameter Name Setting Range Default Code 0: Pre-torque invalid 1: Load cell pre-torque F8-01 Pre-torque selection compensation 2: Automatic pre-torque compensation Pre-torque offset 0.0%–100.0% 50.0% F8-02 Zero servo current coefficient 0.20%–50.0% 15.0%…
  • Page 49
    Use of the NICE3000 Brief NICE3000 Instruction Manual Mechanical Construction ■ The mechanical construction affecting the riding comfort involves the guide rail, guide shoe, steel rope, installation of the brake, balance of the car and the resonance caused by the car, guild rail and motor.
  • Page 50
    Figure 4-7 Monitoring the door open and close limit signals 4.3.7 Password Setting The NICE3000 controller provides the parameter password protection function. Here gives an example of changing the password into 12345, as shown in the following figure. Figure 4-8 Example of changing the password…
  • Page 51
    Use of the NICE3000 Brief NICE3000 Instruction Manual In the password protection unlocked status, you can change the password at any time. The last input number will be the user password. If you want to disable the password protection function, enter the correct password and then set FP-00 to 0.
  • Page 52
    Function Code Table…
  • Page 53: Chapter 5 Function Code Table

    Function Code Table Brief NICE3000 Instruction Manual Chapter 5 Function Code Table Function Parameter Name Setting Range Default Code Group F0: Basic parameters 0: Sensorless flux vector control F0-00 Control mode (SFVC) 1:Closed-loop vector control (CLVC) 0: Operation panel control…

  • Page 54
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code 0: No operation 1: With-load auto-tuning F1-11 Auto-tuning mode selection 2: No-load auto-tuning 3: Shaft auto-tuning F1-12 Encoder lines per revolution 0–10000 1024 F1-13 Encoder fault detection time 0.0–10.0s…
  • Page 55
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code F3-13 Position of down slow-down 1 0.00–300.00 m 0.00 m F3-14 Position of up slow-down 2 0.00–300.00 m 0.00 m F3-15 Position of down slow-down 2 0.00–300.00 m…
  • Page 56
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code F5-01 X1 function selection NO input: 01–31 00: No function F5-02 X2 function selection 01: Up leveling signal F5-03 X3 function selection 02: Down leveling signal…
  • Page 57
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code F5-13 X13 function selection NC input: 33–63 33: Up leveling signal F5-14 X14 function selection 34: Down leveling signal F5-15 X15 function selection 35: Door zone signal…
  • Page 58
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code F5-25 CTB input type selection 0–255 The NO/NC setting of terminals X1 to X8 on the CTB is listed in the following table. Terminal Parameter Name…
  • Page 59
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code F5-32 Communication status display Figure 5-1 Communication status display CANbus Modbus for hall call at each floor The upmost left 7-segment LED is expressed by 0–9, and used for CAN communication monitoring.
  • Page 60
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code F5-34 F5-35 Segment Indication Segment Indication Light curtain 1 Up leveling signal Light curtain 2 Down leveling signal Door 1 open limit Door zone signal Door 2 open limit…
  • Page 61
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code Door machine 1 light curtain Door open button display Door machine 2 light curtain Door close button display Door open delay button Brake feedback 2 display…
  • Page 62
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code • Bit0: Dispersed waiting • Bit1: Reserved • Bit2: Parallel implemented at monitoring port • Bit4: Door not open at power-on if F6-09 Parallel selection elevator-locked signal is enabled •…
  • Page 63
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code Time-based floor service 2 F6-22 00.00–23.59 (hour.minute) 00.00 start time Time-based floor service 2 end F6-23 00.00–23.59 (hour.minute) 00.00 time Floor 1 of time-based floor F6-24 0–65535 (floors 1–16)
  • Page 64
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code F8-05 Current car load 0–1023 F8-06 Car no-load load 0–1023 F8-07 Car full-load load 0–1023 0: Disabled F8-08 Anti-nuisance function 1: Enabled (load cell sensor required)
  • Page 65
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code Group FB: Door function parameters FB-00 Number of door machine (s) 1–2 FB-01 CTB software 0–99 Service floor 1 of door machine FB-02 0–65535 (floors 1–16) 65535 Service floor 2 of door machine…
  • Page 66
    Brief NICE3000 Instruction Manual Function Code Table Function Parameter Name Setting Range Default Code FC-02 Over-load protection coefficient 0.50–10.00 1.00 FC-03 Over-load alarm coefficient 50–100% FC-04 Opposite door selection 1–10 The first two digits indicate the floor and the last two digits indicate the fault code.
  • Page 67
    Function Code Table Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code FC-31 Latest fault time (hour/minute) 00.00–23.59 00.00 Group FD: Communication parameters 0–5: 9600 bps FD-00 Baud rate setting 6: 19200 bps 7: 38400 bps 0: No check-out, data format <8,N,2>…
  • Page 68
    Brief NICE3000 Instruction Manual Overiew Function Parameter Name Setting Range Default Code FE-08 Floor 8 corresponding display 06: display 6 1908 07: display 7 FE-09 Floor 9 corresponding display 1909 08: display 8 FE-10 Floor 10 corresponding display 0100 09: display 9…
  • Page 69
    Overview Brief NICE3000 Instruction Manual Function Parameter Name Setting Range Default Code • Bit0: Attendant function • Bit1: Returning to base floor at fire emergency • Bit2: Re-leveling function • Bit3: Pre-open function • Bit4: Removal of stuck hall calls •…
  • Page 70
    Function Parameter Name Setting Range Default Code • Bit1: Door open holding at door open limit • Bit2: Not output door close signal at door close limit • Bit3: Detecting door close limit in inspection mode • Bit4: Auto reset for running and brake contactor stuck •…
  • Page 72
    System Application…
  • Page 73: Chapter 6 System Application

    6.1 Parallel Mode and Group Mode 6.1.1 Parameter Setting The NICE3000 has the parallel control function. Two NICE3000 controllers can exchange the elevator information by means of CAN or RS485 communication, coordinating response of the two elevators to hall calls and improving the elevator efficiency.

  • Page 74
    Brief NICE3000 Instruction Manual System Application Figure 6-1 Parallel connection by means of CAN communication Elevator Elevator PRG UP SET PRG UP SET CAN communication port CAN communication port connecting CTB of elevator 1# connecting CTB of elevator 2# UP button…
  • Page 75
    Figure 6-2 Parallel connection at the monitoring port 6.1.4 Setting of Physical Floors Physical floors, relative to the NICE3000 control system, are defined by the installation position of the leveling flag. The floor (such as the ground floor) at which the lowest leveling flag is installed corresponds to physical floor 1.
  • Page 76: Emergency Evacuation At Power Failure

    Uninterrupted power supply (UPS) • Shorting PMSM stator Here we first introduce the implementation through the NICE3000’s shorting PMSM stator scheme, which can save energy and improve safety. 6.2.1 Shorting PMSM Stator Shorting PMSM stator means shorting phases UVW of the PMSM, which produces resistance to restrict movement of the elevator car.

  • Page 77
    System Application Brief NICE3000 Instruction Manual Figure 6-3 Wiring of the independent shorting PMSM stator contactor Safety circuit SW: RUN contactor 110 VAC FX: shorting PMSM stator contactor 24 V NICE3000 Motor Then set the related parameters as follows: Table 6-3 Parameter setting under the shorting PMSM stator scheme…
  • Page 78
    Brief NICE3000 Instruction Manual System Application The following figure shows various contacts of the contactors. Figure 6-5 Various contacts of the contactors Phase Safety sequence relay contactor 110 V Safety circuit Emergency 24 V feedback 62 72 53 61 5 13 71 81 The UPS power is recommended in the following table.
  • Page 79: Opposite Door Control

    System Application Brief NICE3000 Instruction Manual 6.3 Opposite Door Control Set related parameters according to the following table. Table 6-6 Parameter setting for opposite door control Opposite Door Parameter Setting Function Description Control Mode FE-33 BIT15 = 0: The hall call buttons of both door sides are connected…

  • Page 80
    Brief NICE3000 Instruction Manual System Application Opposite Door Parameter Setting Function Description Control Mode This control mode applies to double call boards, double operation panels and two CCBs connected in serial. The hall call DIP switch address of the front door is set based on floor (1-15).
  • Page 82
    Troubleshooting…
  • Page 83: Chapter 7 Troubleshooting

    Chapter 7 Troubleshooting 7.1 Description of Fault Levels The NICE3000 has more than 60 pieces of alarm information and protective functions. It monitors various input signals, running conditions and feedback signals. If a fault occurs, the relevant protective function acts and the system displays the fault code.

  • Page 84: Fault Information And Troubleshooting

    Brief NICE3000 Instruction Manual Troubleshooting 7.2 Fault Information and Troubleshooting If an alarm is reported, the system performs corresponding processing based on the fault level. You can handle the fault according to the possible causes described in the following table.

  • Page 85
    Troubleshooting Brief NICE3000 Instruction Manual Fault Name Possible Causes Solution Level Code 8. Check whether the balance coefficient is correct. 9. Check whether the encoder wirings are correct. For asynchronous motor, perform SFVC and compare the current to judge whether the encoder works properly.
  • Page 86
    Brief NICE3000 Instruction Manual Troubleshooting Fault Name Possible Causes Solution Level Code 1. The input voltage is too high. 2. The braking Over-voltage resistance is too during large, or the braking 4. Check whether the cable deceleration unit fails. connecting the braking resistor 3.
  • Page 87
    Troubleshooting Brief NICE3000 Instruction Manual Fault Name Possible Causes Solution Level Code 1. The output wiring 1. Check the wiring. of the main circuit is Power output 2. Check whether the contactor loose. phase loss at the output side is normal.
  • Page 88
    Brief NICE3000 Instruction Manual Troubleshooting Fault Name Possible Causes Solution Level Code 1. Check whether F1-00 is set 1. Check whether correctly. the encoder model 2. Check the encoder wiring. matches the motor. 3. Check whether the encoder 2. The encoder wiring is normal.
  • Page 89
    The CPU is CPU abnormal right two pins of J9 are shorted. abnormal. 2. Contact the agent or Monarch to replace the control board. 1. The feedback speed is 1.15 times of the maximum 1. Check whether the encoder running speed.
  • Page 90
    Brief NICE3000 Instruction Manual Troubleshooting Fault Name Possible Causes Solution Level Code 1. Upon power-on, E35 is reported when the flag height is detected to be 0 or the RUN contactor is detected to keep open. • Check whether the down slow-down switch is valid.
  • Page 91
    Troubleshooting Brief NICE3000 Instruction Manual Fault Name Possible Causes Solution Level Code 1. The RUN contactor feedback is valid 1. Check whether the feedback when the elevator contact of the contactor acts starts up. properly. 2. The feedback 2. Check whether the feedback…
  • Page 92
    Brief NICE3000 Instruction Manual Troubleshooting Fault Name Possible Causes Solution Level Code 1. Check the status of the safety circuit switches. 2. Check whether the external power supply is normal. Safety circuit The safety circuit 3. Check whether the safety breaking signal breaks off.
  • Page 93
    1. Check the communication cable connection. Feedback from the communication 2. Check whether the 24 V CTB is abnormal. abnormal power supply of the NICE3000 is normal. 1. Check the communication cable connection. 2. Check whether the 24 V Feedback from the communication power supply of the NICE3000 HCB is abnormal.
  • Page 94
    Brief NICE3000 Instruction Manual Troubleshooting Fault Name Possible Causes Solution Level Code The door does not open to the limit Stop at another Check the door open limit at the current floor landing floor signal. when the elevator runs automatically.
  • Page 95
    Troubleshooting Brief NICE3000 Instruction Manual — 94 -…
  • Page 96
    The Product Warranty Card is not re-issued. Please keep the card and present it to the maintenance personnel when asking for maintenance. If there is any problem during the service, contact Monarch’s agent or Monarch directly. This agreement shall be interpreted by Suzhou MONARCH Control Technology Co., Ltd.
  • Page 97
    Product Warranty Card Add. of unit: Name of unit: Contact person: Customer information P.C.: Tel.: Product model: Body barcode (Attach here): Product information Name of agent: (Maintenance time and content): Failure information Maintenance personnel:…

Brief NICE3000 Instruction Manual

7.2 Fault Information and Troubleshooting

If an alarm is reported, the system performs corresponding processing based on the fault

level. You can handle the fault according to the possible causes described in the following

table.

Table 7-2 Fault codes and troubleshooting

Fault

Name

Code

Invert unit

E01

protection

Over-current

E02

during

acceleration

Over-current

E03

during

deceleration

Possible Causes

1. The main circuit

output is grounded or

short circuited.

1. Eliminate external faults.

2. The connecting

2. Install a reactor or an output

cable of the motor is

filter.

too long.

3. Check the air channel and

3. The working

the cooling fan.

temperature is too

4. Contact the agent or

high.

Monarch.

4. The internal

connections become

loose.

1. The main circuit

1. Check whether the RUN

output is grounded or

contactor at the controller

short circuited.

output side is normal.

2. Motor auto-

2. Check whether the power

tuning is performed

cable jacket is damaged,

improperly.

whether the power cable is

3. The load is too

possibly short circuited to

heavy.

ground and whether the cable

4. The encoder signal

is connected reliably.

is incorrect.

3. Check the insulation of motor

5. The UPS running

power terminals, and check

feedback signal is

whether the motor winding is

abnormal.

short-circuited or grounded.

4. Check whether the shorting

1. The main circuit

PMSM stator contactor causes

output is grounded or

controller output short circuit.

short circuited.

5. Check whether motor

2. Motor auto-

parameters comply with the

tuning is performed

nameplate.

improperly.

6. Perform motor auto-tuning

3. The load is too

again.

heavy.

7. Check whether the brake

4. The deceleration

keeps released before the fault

rate is too short.

occurs and whether the brake is

5. The encoder is

stuck mechanically.

seriously interfered

(To be continued)

with.

— 83 —

Troubleshooting

Solution

Level

5

5

5

  • Печать

Страницы: 1 14 15 [16] 17 18 32   Вниз

Тема: SJEC. Контроллер NICE 3000  (Прочитано 98324 раз)

0 Пользователей и 1 Гость просматривают эту тему.

Не-не… Никакого гугловского перевода. Только оригинальная английская версия, сначала со словарем…
Благодаря nice3000 мой технический английский стал заметно лучше, чего и всем желаю.


Записан


Не-не… Никакого гугловского перевода.

Да я про то иговорю, механики в заблуждении, и нас вводят в заблуждение.


Записан


Други, подскажите путь решения проблемы. Имеется проблема с включением охраны шахты. На одной из версий прошивок  при  Fd-08-10  и F6-42-bit8-1 сразу вылетает ошибка 64, в этой версии меню «А» отсутствует.
В другой версии, при включении Fd-08-10 и A1-00-000001 вылетает ошибка 81-101. Поиск описания этих ошибок на просторах сети результата не дал.


Записан


Err 64: External fault. Subcode 101: The external fault signal is continuously active for 2s.
Описание 81 ошибки в талмуте нет.
Скорее всего 81 ошибка и используется в качестве ошибки регистрации проникновения в шахту. На моих лифтах с Nice3000 использовалась ошибка 80. Это зависит от прошивки контроллера.


Записан

Уважай лифты: они делают твою жизнь комфортнее


NICE 3000 new, запущен в ревизию. Не выполняет самообучение шахты. Кабина установлена на нижнем этаже в ТО. На индикаторах кнопок вызова отображается режим инспекции при любых положениях переключателей в станции и в посту ревизии. В посту приказов переключателей режимов нет. Ошибка 35/103.
Где искать проблему?


Записан


NICE 3000 new, запущен в ревизию. Не выполняет самообучение шахты. Кабина установлена на нижнем этаже в ТО. На индикаторах кнопок вызова отображается режим инспекции при любых положениях переключателей в станции и в посту ревизии. В посту приказов переключателей режимов нет. Ошибка 35/103.
Где искать проблему?

Кабина должна быть ниже то, ~ на 50мм, датчик нижнего лимита должен быть сработан. В случае обучения лифта на 2 остановки, кабина должна стоять ниже ТО, так чтобы дто был неактивен.


Автоматическое объединение сообщений.


Err 64: External fault. Subcode 101: The external fault signal is continuously active for 2s.
Описание 81 ошибки в талмуте нет.
Скорее всего 81 ошибка и используется в качестве ошибки регистрации проникновения в шахту. На моих лифтах с Nice3000 использовалась ошибка 80. Это зависит от прошивки контроллера.

Уже пояснили что 81 это люк, его контроль активируется вместе с ОШ. Физически, люк отсутствует, на jp22 установлена перемычка. Er64 внешняя ошибка… Здесь вообще непонятно. В пятом меню ни один вход не назначен на external fault.
По прошивкам… FA-05
30.00 L04.50 error 81
19.01 L27.50 error 64
20.12L16.00 работает ОШ


Записан


Anosoff2017,
1. Определись с режимом инспекции. Найди в параметрах F5, какому входу назначен значение параметра 08 или 40 (запись типа F5-__=08 или F5-__=40). Посмотри по схеме,что на данном входе сидит и какой тип сигнала используется (NO/NC).
2. Проверь исходные требования для запуска режима обучения шахте: лифт в режиме инспекция, кабина в зоне точной остановки нижнего этажа, активен сигнал замедления вниз 1 на MCB, отсутствуют ошибки MCB. Если лифт на 2 остановки, то кабина должна стоять ниже шунта.


Записан

Уважай лифты: они делают твою жизнь комфортнее


Существует ли какая-либо возможность просмотреть состояния входов в вызывных аппаратах, используемых для охраны шахты?


Записан


Там специфическое ПО, вызывная плата  сама определяет статус охраны. Контроллер только констатирует ошибку, номер этажа ему неизвестен, только этаж, где находится лифт.


Записан


То есть при открытии ДШ контроллер не сопоставляет местоположение кабины с номером этажа открытой ДШ?
На одном из этажей вызывная плата вообще не была соединена с линией передачи данных, при этом лифт работал…


Записан


Лифт и будет работать, не будет работать вызов. На вызывных платах с ОШ стоят специальные чипы для осуществления этой функции, неисправную плату надо менять на точно такую же, а не стандартную. В контроллере нет охраны шахты, он регистрирует готовую ошибку, переданную с платы.


Записан

спасибо


Где можно прочитать про условия возникновения ошибки 80? Каким образом это всё работает? В официальном представительстве SJEC сказали что только торгуют оборудованием и никакой технической поддержки нет, документации нет.


Записан


Err80
Истек срок наладки
◆ система обнаружила, что срок выполнения наладки по умолчанию, истекает менее чем через 1 день.
◆Сообщить о проблеме менеджеру, ответственного за проект.
Это для NICE 3000NEW

« Последнее редактирование: Март 22, 2020, 10:45:12 от Саня »


Записан


Призрак, У меня только это есть.


Отредактирована ссылка на изображение.

« Последнее редактирование: Март 22, 2020, 11:33:50 от Lift-man »


Записан

спасибо


Это всё примерно понятно. Ситуация такая: на одном из этажей не был подключен вызывной аппарат к линии передачи данных. При этом лифт работал. Значит этот этаж не контролировался. Впрочем, туда кабина и не приезжала.
При проверке балансировки кабину с грузом переместили на пару этажей вниз с нажатой кнопкой стоп на панели. После возвращения в НР сразу после открытия дверей появляется 80, которая никак не сбрасывается.
Всё-таки я думаю местоположение кабины здесь имеет какое то значение.


Записан


  • Печать

Страницы: 1 14 15 [16] 17 18 32   Вверх

(Ocr-Read Summary of Contents of some pages of the Suzhou MONARCH Control Technology Co., Ltd. NICE3000 New Document (Main Content), UPD: 29 July 2023)

  • 8, NICE3000 new User Manual Introduction — 7 — Dual-speed for inspection Considering inaccurate running control at high inspection speed but a long running time at low inspection speed, the system provides the dual-speed curve for inspection, which greatly improves the efciency at inspection. T…

  • 124, Function Code Table NICE3000 new User Manual — 122 — Function Code Parameter Name Setting Range Default Unit Property F8-10 Emergency evacuation operation mode at power failure 0: Motor not running 1: UPS 2: 48 V battery power supply 0 — ★ F8-11 Brake apply delay 0.000–1.000 0.600 s ☆ F8-12 Fire emergency oo…

  • 30, Suzhou MONARCH Control Technology Co., Ltd. NICE3000 New NICE3000 new User Manual Product Information — 29 — 2.6 Optional Parts If any optional part in the following table is required, specify it in your order. Table 2-4 Optional parts of the NICE3000 new Name Model Function Remark External braking unit MDBUN It is provided for the NICE3000 new of 37 kW and above. For details, see section 2.7 «Selection of Bra…

  • 26, NICE3000 new User Manual Product Information — 25 — Note 1. In terms of single-phase and three-phase 220 VAC, NICE-L-A/B-2002 and NICE-L-A/B-2003 are specially designed for 220 VAC. The other models that are marked by prexing «220-» are modied from the three-phase 380 VAC mo…

  • 65, Mechanical and Electrical Installation NICE3000 new User Manual — 64 — Table 3-17 Slow-down distances based on different rated elevator speeds Rated Elevator Speed V ≤ 1.5 m/s 1.5 m/s < V ≤ 2.4 m/s 2.4 m/s < V ≤ 3.7 m/s Distance of slow-down 1 1.3 m to H/2 1.3 m 1.3 m Distance of slow-down 2 — 3.2 m 3.2 m Distance of slow-down 3 — — 8.0 m Note • «H» in…

  • 116, Function Code Table NICE3000 new User Manual — 114 — Function Code Parameter Name Setting Range Default Unit Property F6-07 Number of elevators in group mode 1–8 1 — ★ F6-08 Elevator No. 1–8 1 — ★ F6-09 Elevator program control Bit0: Dispersed waiting Bit2: Parallel implemented at monitoring port Bit3: Parallel implemented at CAN2 Bit4: Parallel control in co…

  • 186, Suzhou MONARCH Control Technology Co., Ltd. NICE3000 New Description of Function Codes NICE3000 new User Manual — 184 — Table 7-16 Communication quality display LED 5 LED 4 LED 3 LED 2 LED 1 SPI Communication Quality No Display CAN2 Communication Quality Modbus Communication Quality CAN1 Communication Quality 0 Good — 0 Good 0 Good 0 Good · · · · · · · · · · · · · · · · 9 Interrupted 9 Interrupted 9 Interrupted 9 Interrupted 0–9 indicates …

  • 203, NICE3000 new User Manual Description of Function Codes — 201 — to exit the leveling adjustment state. Then, car calls can be registered. 21. Press the door close button, and press the button for the next oor. The elevator runs to the next oor and keeps the door open after arrival. Then, you can perform leveling adjustment.…

  • 214, EMC NICE3000 new User Manual — 212 —

  • 133, NICE3000 new User Manual Function Code Table — 131 — Function Code Parameter Name Setting Range Default Unit Property FE-07 Floor 7 display 17: Display «R» 18: Display «-» 19: No display 20: Display «12» 21: Display «13» 22: Display «23» 23: Display «C» 24: Display «D» 25: Display «E» 26: Display «F» 27: Displ…

  • 7, Introduction NICE3000 new User Manual — 6 — Service suspension output When the elevator cannot respond to hall calls, the corresponding terminal outputs the service suspension signal. Running times recording In automatic running state, the system automatically records the running times of the elevator. Running time recording The …

  • 194, Description of Function Codes NICE3000 new User Manual — 192 — Function Code Parameter Name Setting Range Default Unit Property FC-04 Opposite door selection 0–3 0 — ★ It is used to set opposite door-related control function. The values are as follows: • 0: Simultaneous control • 1: Hall call independent, car call simultaneous • 2: Hall call ind…

  • 102, Suzhou MONARCH Control Technology Co., Ltd. NICE3000 New System Commissioning and Application Example NICE3000 new User Manual — 100 — Table 5-12 Selection of the opposite door mode Opposite Door Mode Parameter Setting Function Description Use Method Old mode (same as the NICE3000) Mode 1 FE-33 Bit15 = 1; Fb-00 = 2 FC-04 = 0 (Simultaneous control) The front door and back door acts simultaneously upon arrival for hall calls and car calls. The hall call …

  • 131, NICE3000 new User Manual Function Code Table — 129 — Function Code Parameter Name Setting Range Default Unit Property FD-07 HCB:JP1 input 0: Reserved NO/NC input: 1/33: Elevator lock signal 2/34: Fire emergency signal 3/35: Current oor forbidden 4/36: VIP oor signal 5/37: Security oor signal 6/38: Door close button input 1 — �…

  • 209, NICE3000 new User Manual EMC — 207 — Controller Model Power Capacity Rated Input Current AC Input Filter Model AC Input Filter Model kVA A Changzhou Jianli (Schaffner) 220-NICE-L-C-4011 12.1 36.0 DL-40K3 Consult the manufacturer. 220-NICE-L-C-4015 13.9 41.0 DL-50T3 220-NICE-L-C-4018 17.3 40.0 DL-50T3 220-NICE-L-C-4022 23.1 49.0 DL-50T3 220-NICE-L-C-4030 33.0 61…

  • 208, EMC NICE3000 new User Manual — 206 — Table 8-1 Recommended manufacturers and models of EMC lter Controller Model Power Capacity Rated Input Current AC Input Filter Model AC Input Filter Model kVA A Changzhou Jianli (Schaffner) Three-phase 380 V NICE-L-C-4002 4.0 6.5 DL-10EBK5 FN 3258-7-44 NICE-L-C-4003…

  • 149, NICE3000 new User Manual Description of Function Codes — 147 — Group F4: Floor Parameters Function Code Parameter Name Setting Range Default Unit Property F4-00 Leveling adjustment 0–60 30 mm ★ It is used to adjust the leveling accuracy at elevator stop. If over-leveling occurs in elevator stop at all oors, decrease the value of this parameter properly. If under-leveling oc…

  • 164, Suzhou MONARCH Control Technology Co., Ltd. NICE3000 New Description of Function Codes NICE3000 new User Manual — 162 — Table 7-7 Functions indicated by bits of F6-09 Bit Function Description Default Bit1 Disabling returning to base oor for verication The function of returning to base oor for verication due to large deviation of the car position is disabled. 0 Bit2 Cancelling auto sequential arrange of hall call…

Автор Сообщение

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Пт, 27 фев 2015, 09:46 

Не в сети
Активный пользователь
Аватара пользователя



Зарегистрирован: Вс, 04 авг 2013, 13:53
Сообщения: 230
Откуда: Казахстан.Алмата

Реальное имя: Тимур

Завтра только на лифт попаду…буду разбираться…


_________________
— Нет ничего более стимулирующего, чем когда всё идёт не так как надо.

Вернуться к началу

Профиль Отправить личное сообщение  

maxman11

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Ср, 04 мар 2015, 15:07 



Зарегистрирован: Сб, 06 мар 2010, 15:01
Сообщения: 41
Откуда: Абакан

SKYPE: maxman115

Реальное имя: Алексей

Вернуться к началу

Профиль Отправить личное сообщение  

пэлк

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Вт, 05 май 2015, 19:52 

Не в сети
Новичок



Зарегистрирован: Вс, 15 мар 2015, 13:07
Сообщения: 16

Уважаемые колеги помогите ошибка er 41 безопасность собрал пускатель сработал но ошибка все равно осталось что делать ?? За ранее благодарен

Вернуться к началу

Профиль Отправить личное сообщение  

Джентльмен

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Ср, 06 май 2015, 14:24 



Зарегистрирован: Вт, 21 фев 2012, 01:04
Сообщения: 505
Откуда: Россия

Реальное имя: Dmitrii

Цепи собрал, пускатель сработал, а соответствующая индикация на входе контроллера появилась????

Вернуться к началу

Профиль Отправить личное сообщение  

пэлк

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Ср, 06 май 2015, 15:58 

Не в сети
Новичок



Зарегистрирован: Вс, 15 мар 2015, 13:07
Сообщения: 16

Убил я 41 ошибку.теперь пише ер 52 и едеть зараза только вниз.вверх вообще не реагирует что может быть подскажите уважаемые колеги

Вернуться к началу

Профиль Отправить личное сообщение  

Джентльмен

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Ср, 06 май 2015, 16:00 



Зарегистрирован: Вт, 21 фев 2012, 01:04
Сообщения: 505
Откуда: Россия

Реальное имя: Dmitrii

Данную тему почитай с первой страницы, это уже обсуждалось.

Вернуться к началу

Профиль Отправить личное сообщение  

пэлк

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Пт, 08 май 2015, 07:47 

Не в сети
Новичок



Зарегистрирован: Вс, 15 мар 2015, 13:07
Сообщения: 16

Вернуться к началу

Профиль Отправить личное сообщение  

YAN

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Пт, 15 май 2015, 12:01 

Не в сети
Новичок



Зарегистрирован: Чт, 16 сен 2010, 15:19
Сообщения: 8

Уважаемые коллеги подскажите, что означает ошибка Еrr58. В документации NICE3000 нет описания этой ошибки. Цепи безопасности собраны, двери закрыты, но в инспекции не идет.

Вернуться к началу

Профиль Отправить личное сообщение  

tim55

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Сб, 16 май 2015, 00:44 



Зарегистрирован: Вс, 04 авг 2013, 13:53
Сообщения: 230
Откуда: Казахстан.Алмата

Реальное имя: Тимур

Лифт на стадии наладки?
Какие светодиоды горят??


_________________
— Нет ничего более стимулирующего, чем когда всё идёт не так как надо.

Вернуться к началу

Профиль Отправить личное сообщение  

Naladchik2006

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Сб, 16 май 2015, 01:03 



Зарегистрирован: Вт, 09 июн 2009, 20:13
Сообщения: 5372
Откуда: Москва

SKYPE: naladchik2006

Реальное имя: Евгений

Да описывали уже эту ошибку на обоих форумах.


_________________
постоянно всё забываю — так что если кому-то что-то пообещал -напоминайте.

Вернуться к началу

Профиль Отправить личное сообщение  

пэлк

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Вс, 17 май 2015, 15:41 

Не в сети
Новичок



Зарегистрирован: Вс, 15 мар 2015, 13:07
Сообщения: 16

Господа наладчики подскажите найс 3000 ошибка ер 80 кто сталкивался?

Вернуться к началу

Профиль Отправить личное сообщение  

Джентльмен

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Вс, 17 май 2015, 17:07 



Зарегистрирован: Вт, 21 фев 2012, 01:04
Сообщения: 505
Откуда: Россия

Реальное имя: Dmitrii

Судя по мануалу, а конкретно по спецификации контрольной системы, 80- конечный выключатель. Я бы посмотрел на индикацию входных сигналов для начала.

Вернуться к началу

Профиль Отправить личное сообщение  

Naladchik2006

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Вс, 17 май 2015, 17:48 



Зарегистрирован: Вт, 09 июн 2009, 20:13
Сообщения: 5372
Откуда: Москва

SKYPE: naladchik2006

Реальное имя: Евгений

80-я это тест на логику. :lol:


_________________
постоянно всё забываю — так что если кому-то что-то пообещал -напоминайте.

Вернуться к началу

Профиль Отправить личное сообщение  

Джентльмен

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Вс, 17 май 2015, 18:04 



Зарегистрирован: Вт, 21 фев 2012, 01:04
Сообщения: 505
Откуда: Россия

Реальное имя: Dmitrii

Злюка :cry:

Вернуться к началу

Профиль Отправить личное сообщение  

пэлк

Заголовок сообщения: Re: NICE 3000

Новое сообщениеДобавлено: Пн, 18 май 2015, 16:20 

Не в сети
Новичок



Зарегистрирован: Вс, 15 мар 2015, 13:07
Сообщения: 16

Господа наладчики подскажите найс 3000 ошибка ер 16 кто сталкивался за ранее спасибо

Вернуться к началу

Профиль Отправить личное сообщение  

Понравилась статья? Поделить с друзьями:
  • Nikon d80 ошибка затвора
  • Nic ru ошибка 500
  • Nikon d80 ошибка затвор
  • Nikon d80 ошибка r06
  • Nic ru ssl ошибка валидации