Multplayovercaps rvi ошибка

Here is a profile from one of the laptops we are using. Ports are forwarded using the TCP/UDP modes, we also tried TCP only mode. No firewall or VLANS. Multiple clients?, we are only connecting to one NVR at this point. PSS suite has NO Problems loading all the camera feeds. Only the NEW SmartPSS has problems, this makes me think its solely software programing by Dahua. They [Dahua] are also having me work with R&D on this problem because they have not had any reports yet. The web connection is not a problem we have a 50mbps up/ 10mpbs down.

LAN speed is 150mbps.

System

———————————————————————————

Manufacturer Hewlett-Packard

Model HP Pavilion dv6000 (RP283UA#ABA)

Total amount of system memory 3.00 GB RAM

System type 32-bit operating system Windows 7 Professional

Number of processor cores 2

64-bit capable Yes

Graphics

———————————————————————————

Display adapter type Mobile Intel® 945 Express Chipset Family

Total available graphics memory 256 MB

Dedicated graphics memory 0 MB

Dedicated system memory 64 MB

Shared system memory 192 MB

Display adapter driver version 8.15.10.1930

Primary monitor resolution 1280×800

DirectX version DirectX 9.0 or better

I might add this PC has no problems loading 64 channels on a Exacq recorder using the Exacq software, also Digiop works fine also.

Регистраторы видеонаблюдения RVI являются одними из самых популярных на рынке, благодаря своей надежности и простоте использования. Однако, возникают ситуации, когда к регистратору не удается подключить новую камеру. Рассмотрим пять возможных причин, почему это может происходить.

1. Неправильный формат сигнала

Одной из самых распространенных причин является неправильный формат сигнала камеры, к которой вы пытаетесь подключиться. Регистратор не сможет обработать сигнал, если он будет иметь несоответствующий формат или низкое качество изображения.

2. Неправильно введены настройки подключения

Если вы неправильно ввели настройки подключения к камере, регистратор не сможет ее распознать. Важно убедиться, что вы правильно ввели IP-адрес, логин и пароль для подключения.

3. Ограниченное количество подключений

Регистратор RVI может иметь ограниченное количество мест для подключения камер, в зависимости от модели. Если вы уже подключили максимальное количество камер, новую камеру подключить не получится.

4. Проблемы с кабелем

Если камера не подключается к регистратору, возможно, проблема в кабеле. Проверьте, что кабель правильно подключен и не поврежден. Если кабель испорчен, замените его на новый.

5. Проблемы с камерой

Наконец, возможно, проблема может быть в самой камере. Проверьте, что камера правильно работает и не имеет технических проблем. Если камера исправна, попробуйте выполнить перезапуск регистратора.

Вывод

Регистратор RVI является надежным инструментом для видеонаблюдения, но иногда возникают проблемы при подключении новых камер. Надеемся, что описанные причины помогут вам разобраться с возможными причинами неполадок и решить проблему быстро и эффективно.

Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

Posted on 25.03.2017 in Настройка ОС и программ

Провели оптику, поставили оптический медиаконвертер, от него провод в роутер TP-Link. От роутера в регистратор, компьютер, телевизор.

P 20181208 161723 e1544424877799 500x420 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

P 20181208 161740 e1544425060817 500x335 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

Настраиваем роутер, здесь всё как обычно: в Wan настройки подключения к интернету, включаем DHCP и Wi-fi, всё автоматом. Интернет появился.

Обязательно включаем службу UPnP, с помощью которой устройcтва сети могут сами разрешить необходимые им подключения. Если по какой-либо причине вы не можете использовать протокол UPnP, то для корректной работы необходимо будет вручную настроить трансляцию сетевых IP-адресов (NAT), чтобы в интернет-центре открыть доступ по портам, которые использует программа, сетевое устройство или сервер.

Какие порты нужны. Проброс

Порты необходимые для работы:

  • 80 — для подключения через браузер (HTTP), веб-­интерфейс (я поменял на 81 порт),
  • 37777 для протокола TCP,
  • 37778 — UDP,
  • 554 — RTSP-порт для прямого получения потока с камеры.

Теперь делаем проброс портов, на видеорегистратор RVi нужно пробросить порты 37777 и 37778, должно получится так:

P 20181208 162150 e1544426375564 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

102 — адрес регистратора, его ставим на нем вручную, статику. Настраиваем регистратор:

P 20181208 171026 500x255 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

P 20181208 171036 500x194 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

Создаю в разделе аккаунта регистратора пользователя с правами просмотра. С его помощью будем подключаться с телефона смотреть камеры. Качаем на телефон приложение gDMSS plus, для андройда.

Выбираем в нём регион Россия, далее camera — wired device и жмём кнопку сканировать QR код. В регистраторе идём в раздел P2P настройки, сканируем наш код и всё — теперь камеры видны. Но это не из локальной сети, а с мобильного интернета.

P 20181208 171108 500x341 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

Screenshot 20181208 171707 500x889 - Настройка регистратора RVI. Проброс портов на роутере. Подключение извне к камерам

Страницу просмотрели: 15 485

Собственно обнови по этапно все части прошивки(кроме U-boot) и вот что имеем сейчас

Код: Выделить всё

Terminal log file
Date: 18.07.2017 - 8:41:16
-----------------------------------------------
FB_FEED

U-Boot 2010.06-svn1455 (Sep 22 2014 - 19:29:18)

DRAM:  256 MiB
Check spi flash controller v300. found
Spi(cs1) ID: 0xEF 0x40 0x18 0x00 0x00 0x00
Spi(cs1): Block:64KB Chip:16MB Name:"W25Q128BV"
the size of spi flash is 0x1000000
In:    serial
Out:   serial
Err:   serial
judge ddr init
user init finish.C
Hit any key to stop autoboot:  3  2  1  0
Phy use RGMII!
netup time out: 1000
Timeout
Phy use RGMII!
TFTP from server 192.168.254.254; our IP address is 192.168.1.108; sending through gateway 192.168.1.1
Download Filename 'upgrade_info_7db780a713a4.txt'.
Download to address: 0x80100000
Downloading: *T T T
Retry count exceeded; starting again
Failed to get info.txt
### JFFS2 loading '/boot/uImage' to 0x82000000
squashfs use lzma
### squashfs loading '/boot/uImage' to 0x82000000
squashfs use lzma
### squashfs load complete: 2273056 bytes loaded to 0x82000000
## Booting kernel from Legacy Image at 82000000 ...
   Image Name:   Linux-3.0.8
   Image Type:   ARM Linux Kernel Image (uncompressed)
   Data Size:    2272992 Bytes = 2.2 MiB
   Load Address: 80008000
   Entry Point:  80008000
   Loading Kernel Image ... OK
OK

Starting kernel ...

Uncompressing Linux... done, booting the kernel.
Linux version 3.0.8 (he_liangbin@localhost.localdomain) (gcc version 4.4.1 (Hisilicon_v200(gcc4.4-290+glibc-2.11+eabi+nptl)) ) #3 SMP Tue May 20 19:32:54 CST 2014, svn:3264
CPU: ARMv7 Processor [413fc090] revision 0 (ARMv7), cr=10c53c7f
CPU: VIPT nonaliasing data cache, VIPT aliasing instruction cache
Machine: godnet
Memory policy: ECC disabled, Data cache writealloc
chip type is hi3531
bus_clk = 310000000
PERCPU: Embedded 7 pages/cpu @c07d3000 s5120 r8192 d15360 u32768
Built 1 zonelists in Zone order, mobility grouping on.  Total pages: 63500
Kernel command line: mem=250M, console=ttyAMA0,115200 rootfstype=squashfs root=/dev/mtdblock1 dh_keyboard=0 load_modules=1 chiptype=2 sim_video_ch=0 dig_video_ch=0
PID hash table entries: 1024 (order: 0, 4096 bytes)
Dentry cache hash table entries: 32768 (order: 5, 131072 bytes)
Inode-cache hash table entries: 16384 (order: 4, 65536 bytes)
Memory: 250MB = 250MB total
Memory: 247724k/247724k available, 8276k reserved, 0K highmem
Virtual kernel memory layout:
    vector  : 0xffff0000 - 0xffff1000   (   4 kB)
    fixmap  : 0xfff00000 - 0xfffe0000   ( 896 kB)
    DMA     : 0xffc00000 - 0xffe00000   (   2 MB)
    vmalloc : 0xd0000000 - 0xfe000000   ( 736 MB)
    lowmem  : 0xc0000000 - 0xcfa00000   ( 250 MB)
    modules : 0xbf000000 - 0xc0000000   (  16 MB)
      .init : 0xc0008000 - 0xc0036000   ( 184 kB)
      .text : 0xc0036000 - 0xc0543000   (5172 kB)
      .data : 0xc0544000 - 0xc056dd40   ( 168 kB)
       .bss : 0xc056dd64 - 0xc05d7bdc   ( 424 kB)
SLUB: Genslabs=13, HWalign=32, Order=0-3, MinObjects=0, CPUs=2, Nodes=1
Hierarchical RCU implementation.
NR_IRQS:128 nr_irqs:128 128
sched_clock: 32 bits at 155MHz, resolution 6ns, wraps every 27709ms
sched_clock: wrong multiply/shift: 432960413>>26 vs calculated 3463683303>>29
sched_clock: fix multiply/shift to avoid scheduler hiccups
Console: colour dummy device 80x30
Calibrating delay loop... 1849.75 BogoMIPS (lpj=9248768)
pid_max: default: 32768 minimum: 301
Mount-cache hash table entries: 512
CPU: Testing write buffer coherency: ok
Calibrating local timer... 154.96MHz.
CPU1: Booted secondary processor
Brought up 2 CPUs
SMP: Total of 2 processors activated (3706.06 BogoMIPS).
NET: Registered protocol family 16
Serial: AMBA PL011 UART driver
uart:0: ttyAMA0 at MMIO 0x20080000 (irq = 40) is a PL011 rev2
console [ttyAMA0] enabled
uart:1: ttyAMA1 at MMIO 0x20090000 (irq = 41) is a PL011 rev2
uart:2: ttyAMA2 at MMIO 0x200a0000 (irq = 42) is a PL011 rev2
uart:3: ttyAMA3 at MMIO 0x200b0000 (irq = 43) is a PL011 rev2
bio: create slab <bio-0> at 0
SCSI subsystem initialized
usbcore: registered new interface driver usbfs
usbcore: registered new interface driver hub
usbcore: registered new device driver usb
cfg80211: Calling CRDA to update world regulatory domain
Switching to clocksource timer1
NET: Registered protocol family 2
IP route cache hash table entries: 2048 (order: 1, 8192 bytes)
TCP established hash table entries: 8192 (order: 4, 65536 bytes)
TCP bind hash table entries: 8192 (order: 4, 65536 bytes)
TCP: Hash tables configured (established 8192 bind 8192)
TCP reno registered
UDP hash table entries: 128 (order: 0, 4096 bytes)
UDP-Lite hash table entries: 128 (order: 0, 4096 bytes)
NET: Registered protocol family 1
RPC: Registered named UNIX socket transport module.
RPC: Registered udp transport module.
RPC: Registered tcp transport module.
RPC: Registered tcp NFSv4.1 backchannel transport module.
L2cache cache controller enabled
 *** min_free_kbytes=2015, tmp = 2012, min=2012
 *** WMARK_LOW = 2512, WMARK_HIGH=3016
 *** min_free_kbytes=2015, tmp = 0, min=0
 *** WMARK_LOW = 0, WMARK_HIGH=0
squashfs: version 4.0 (2009/01/31) Phillip Lougher
JFFS2 version 2.2. (NAND) В© 2001-2006 Red Hat, Inc.
msgmni has been set to 483
alg: No test for stdrng (krng)
Block layer SCSI generic (bsg) driver version 0.4 loaded (major 254)
io scheduler noop registered
io scheduler deadline registered (default)
io scheduler cfq registered
brd: module loaded
loop: module loaded
ahci ahci.0: ********** turning off CAP_NCQ
ahci: SSS flag set, parallel bus scan disabled
ahci ahci.0: AHCI 0001.0200 32 slots 2 ports 3 Gbps 0x3 impl platform mode
ahci ahci.0: flags: sntf stag pm led clo only pmp pio slum part ccc sxs boh
scsi0 : ahci_platform
scsi1 : ahci_platform
ata1: SATA max UDMA/133 mmio [mem 0x10080000-0x1008ffff] port 0x100 irq 68
ata2: SATA max UDMA/133 mmio [mem 0x10080000-0x1008ffff] port 0x180 irq 68
Spi id table Version 1.22
Hisilicon Spi Flash Controller V300 New Device Driver, Version 1.10
Check Spi Flash Controller V300 New.
Found
Spi(cs1) ID: 0xEF 0x40 0x18 0x00 0x00 0x00
Spi(cs1):
Block:64KB
Chip:16MB
Name:"W25Q128BV"
partitions[0] = {.name = boot+env, .offset = 0x00000000, .size = 0x00060000 (384KiB) }
partitions[1] = {.name = rootfs, .offset = 0x00060000, .size = 0x00c80000 (12800KiB) }
partitions[2] = {.name = web, .offset = 0xffffffff, .size = 0x00180000 (1536KiB) }
partitions[3] = {.name = custom, .offset = 0xffffffff, .size = 0x00020000 (128KiB) }
partitions[4] = {.name = logo, .offset = 0xffffffff, .size = 0x00040000 (256KiB) }
partitions[5] = {.name = config, .offset = 0xffffffff, .size = 0x00000000 (0KiB) }
Creating 6 MTD partitions on "hi_sfc":
0x000000000000-0x000000060000 : "boot+env"
0x000000060000-0x000000ce0000 : "rootfs"
0x000000ce0000-0x000000e60000 : "web"
0x000000e60000-0x000000e80000 : "custom"
0x000000e80000-0x000000ec0000 : "logo"
0x000000ec0000-0x000001000000 : "config"
Fixed MDIO Bus: probed
STMMAC driver:
   platform registration...
   done!
Set system config register 0x200300ec with value 0x003f003f
   done!
   DWMAC1000 - user ID: 0x10, Synopsys ID: 0x36
   Enhanced descriptor structure
MACADDR in get is 0:0:0:0:0:0
   eth0 - (dev. name: stmmaceth - id: 0, IRQ #119
   IO base addr: 0xd01c0000)
STMMAC MII Bus: probed
cccaaa  :addr =3, priv->phy_addr =3
eth0: PHY ID 00070431 at 3 IRQ -6 (1:03) active
stmmac_reset: RESET COMPLETE!

**************************************************
*  TNK driver built on May 20 2014 at 19:32:25
*  TNK driver mode is BYPASS
**************************************************
stmmac: Rx Checksum Offload Engine supported
PPP generic driver version 2.4.2
PPP Deflate Compression module registered
PPP BSD Compression module registered
PPP MPPE Compression module registered
NET: Registered protocol family 24
usbmon: debugfs is not available
ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver
hiusb-ehci hiusb-ehci.0: HIUSB EHCI
hiusb-ehci hiusb-ehci.0: new USB bus registered, assigned bus number 1
hiusb-ehci hiusb-ehci.0: irq 63, io mem 0x100b0000
hiusb-ehci hiusb-ehci.0: USB 0.0 started, EHCI 1.00
hub 1-0:1.0: USB hub found
hub 1-0:1.0: 2 ports detected
ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver
hiusb-ohci hiusb-ohci.0: HIUSB OHCI
hiusb-ohci hiusb-ohci.0: new USB bus registered, assigned bus number 2
hiusb-ohci hiusb-ohci.0: irq 64, io mem 0x100a0000
hub 2-0:1.0: USB hub found
hub 2-0:1.0: 2 ports detected
usbcore: registered new interface driver cdc_acm
cdc_acm: USB Abstract Control Model driver for USB modems and ISDN adapters
usbcore: registered new interface driver cdc_wdm
Initializing USB Mass Storage driver...
usbcore: registered new interface driver usb-storage
USB Mass Storage support registered.
usbcore: registered new interface driver ums-alauda
usbcore: registered new interface driver ums-datafab
usbcore: registered new interface driver ums-freecom
usbcore: registered new interface driver ums-isd200
usbcore: registered new interface driver ums-jumpshot
ata1: SATA link down (SStatus 0 SControl 300)
usbcore: registered new interface driver ums-sddr09
usbcore: registered new interface driver ums-sddr55
usbcore: registered new interface driver mdc800
mdc800: v0.7.5 (30/10/2000):USB Driver for Mustek MDC800 Digital Camera
mousedev: PS/2 mouse device common for all mice
usbcore: registered new interface driver usbhid
usbhid: USB HID core driver
TCP cubic registered
Initializing XFRM netlink socket
NET: Registered protocol family 10
Mobile IPv6
IPv6 over IPv4 tunneling driver
NET: Registered protocol family 17
NET: Registered protocol family 15
lib80211: common routines for IEEE802.11 drivers
Registering the dns_resolver key type
VFP support v0.3: implementor 41 architecture 3 part 30 variant 9 rev 4
registered taskstats version 1
шata2: SATA link down (SStatus 0 SControl 300)
squashfs use lzma
VFS: Mounted root (squashfs filesystem) readonly on device 31:1.
Freeing init memory: 184K
[RCS]: /etc/init.d/S00devs
[RCS]: /etc/init.d/S01udev
[RCS]: /etc/init.d/S80network
[RCS]: /etc/init.d/S81toe
[RCS]: /etc/init.d/S99dahua
squashfs use lzma
 *** min_free_kbytes=5120, tmp = 5120, min=5120
 *** WMARK_LOW = 6400, WMARK_HIGH=7680
 *** min_free_kbytes=5120, tmp = 0, min=0
 *** WMARK_LOW = 0, WMARK_HIGH=0

7z ANSI-C Decoder 9.20 : Igor Pavlov : Public domain : 2010-11-18

Extracting adec.ko
Extracting aenc.ko
Extracting ai.ko
Extracting ao.ko
Extracting avss.ko
Extracting base.ko
Extracting chnl.ko
Extracting driverbox.ko
Extracting dsu.ko
Extracting flashtool.ko
Extracting group.ko
Extracting h264e.ko
Extracting hdmi.ko
Extracting hidmac.ko
Extracting hifb.ko
Extracting ive.ko
Extracting jpeg.ko
Extracting jpege.ko
Extracting mmz.ko
Extracting pciv.ko
Extracting pciv_fmw.ko
Extracting rc.ko
Extracting region.ko
Extracting rt5370sta.ko
Extracting sio.ko
Extracting sys.ko
Extracting tde.ko
Extracting usbserial.ko
Extracting vcmp.ko
Extracting vda.ko
Extracting vdec.ko
Extracting venc.ko
Extracting vfmw.ko
Extracting viu.ko
Extracting vou.ko
Extracting vpss.ko
Extracting watchdog.ko

Everything is Ok
Hisilicon Media Memory Zone Manager
driverbox load begin!
version:V1.0 Jun 16 2014, 17:35:56
cpu type is HI3531
DRIVER:regisetr gpio miscdevice Jun 16 2014, 17:35:57
DVR_DRV-gpio MSG: product type gpio value: 0x12
DVR_DRV-gpio MSG: product=0, sub_product=2, Area:Abroad
DVR_DRV-gpio MSG: DMA clock register value: 2
DVR_DRV-gpio MSG: Reset AD2964 or AD2968
DVR_DRV-gpio MSG: port= 0x20250000, bit=5, value = 0
DVR_DRV-gpio MSG: port= 0x20250000, bit=5, value = 32
DRIVER: regisetr hardware_id miscdevice Jun 16 2014, 17:35:58
DVR_DRV-csb_device MSG: after hwid analyse, DvrHwid=0x83150406ace4070e
DVR_DRV-csb_device ERR: FUNC:configfile_hwid_init() 1512  open hwid config file failed
**********************************************************************
|                          SYSTEM INFORMATION                   
|          cpld version:  1.02
|          product type:  DVR
|              CPU chip:  HI3531
|              DSP chip:  NONE
|            video chip:  TW2964-960
|     analog audio mode:  STxx control
|       audio interface:  Self_audio
|       frontboard type:  Base
|           abroad info:  Abroad
|            rtc vendor:  Dallas
|         video channel:  16
|         audio channel:  4
|         digital video:  0
|              alarm in:  16
|             alarm out:  3
|              disk num:  2
|              net card:  1
|               dsp num:  0
|         audio support:  YES
|        matrix support:  YES
|         esata support:  NO
|      frontboard digit:  NO
|      frontboard shift:  YES
|        RS232 surpport:  YES
|        RS485 surpport:  YES
|      product sub type:  Default
|           app version:  2.608
|           encode type:  D1 real-time
**********************************************************************
DRIVER:regisetr resource miscdevice Jun 16 2014, 17:35:57
DVR_DRV-resource MSG: Get DVR product resource data!
DRIVER: disk resource, sata_num=2, esata_num=0, pm_flag = 0
DVR_DRV-resource MSG: Alarm type: IIC!
DRIVER: regisetr gpio_i2c miscdevice Jun 16 2014, 17:35:57
DVR_DRV-gpioi2c MSG: i2c_info[00]: SCL=12.5 SDA=12.4
DVR_DRV-gpioi2c MSG: i2c_info[01]: SCL=10.5 SDA=10.4
DVR_DRV-gpioi2c MSG: mcu_i2c: SCL=12.2 SDA=12.3
DVR_DRV-gpioi2c MSG: Data=0x11, RTC oscillator is enable
DRIVER: cmos miscdevice Jun 16 2014, 17:35:59
DVR_DRV-cmos MSG: cmos use dev 0xd0 offset 0x8
DRIVER: regisetr rtc miscdevice Jun 16 2014, 17:35:59
DRIVER: alarm miscdevice Jun 16 2014, 17:35:59
DRIVER:regisetr console miscdevice Jun 16 2014, 17:35:59
driverbox load end!
hi3531_base: module license 'Proprietary' taints kernel.
Disabling lock debugging due to kernel taint
Hisilicon UMAP device driver interface: v3.00
load sys.ko for Hi3531...OK!
Load tde.ko ...OK!
load venc.ko for Hi3531...OK!
load group.ko for Hi3531...OK!
load chnl.ko for Hi3531...OK!
load h264e.ko for Hi3531...OK!
load rc.ko for Hi3531...OK!
load jpege.ko for Hi3531...OK!
load viu.ko for Hi3531...OK!
load vou.ko ....OK!
load vpss.ko ....OK!
load vda.ko ....OK!
load region.ko ....OK!
load vdec.ko ....OK
insmod: can't open '/var/lib/hiuser.ko#20140505': No such file or directory
load vhd firmware.ko OK
load hdmi.ko ....OK!
Load jpeg6b.ko success.      (SDK_VERSION:[jpeg6bv1.0] Build Time:[Mar 20 2013, 01:13:37])
DVR_DRV-csb_device MSG: Invalid CLPD Info command 25!
ial support registered for generic
usbcore: registered new interface driver usbserial_generic
usbserial: USB Serial Driver core
rtusb init rt2870 --->
rt3070_2.5.0.3 SVN_VERSION:2710 Complie time Dec 25 2013 16:16:47
usbcore: registered new interface driver rt2870
MACADDR in set is 4c:11:bf:14:dc:28
ADDRCONF(NETDEV_UP): eth0: link is not ready
---------------------------------
PHY: 1:03 - Link is Up - 100/Full
ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready
Extracting Challenge

Everything is Ok
[LIBDVR] LIBDVR_TOOL: dvrhelper version: 5042(Aug  2 2013 13:59:31)

-----------------------------------------------
Date: 18.07.2017 - 8:41:55
End log file

  • #1

Не могу подключить RVI-HDR04MA через smart pss. По IP пишет что устройство оффлайн(не найден сетевой хост). в то е время RVI-1HDR1081L прекрасно работает. через браузер могу подключится к регистратору через программу нет. версия программы свежая, версия прошивки не знаю, (V3.5build 180808).Сеть изолирована от интернета.

Останнє редагування:

Понравилась статья? Поделить с друзьями:
  • Multitronics ошибки системы
  • Multitronics x150 коды ошибок
  • Multitronics x115 коды ошибок
  • Multitronics vc731 сброс ошибок
  • Multitronics sl 50 gazel коды ошибок