Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
INGLES — ENGLISH
BLOCK OF EXCHANGEABLE TUBES
GUIDE MANUAL
1 de 40
MNP11M01GB06
May 2007- Rev.4
Page:
Summary of Contents for Jofemar J-2000
-
Page 1
INGLES — ENGLISH BLOCK OF EXCHANGEABLE TUBES GUIDE MANUAL 1 de 40 MNP11M01GB06 May 2007- Rev.4 Page:… -
Page 2
Before connecting, make sure the voltage is correct. Consult appendix 5 of this manual to install the compact. We recommend you to read this instruction manual before connecting the compact. Jofemar S.A. Ctra. de Marcilla Km.2, 31350 Peralta. Navarra, Spain. http: // www.jofemar.com Tel. -
Page 3: Table Of Contents
INDEX: .- WORKING CONDITION 2.- SYMBOL OF THE INSTRUCTIONS MANUAL 3.- INTRODUCTION TO MODEL J-2000. T10 VALIDATOR. COIN SEPARATOR REFUND SLIDE: INSTALLATION OF THE COMPACT CLEANING OF THE VALIDATOR. COIN JAMS AND TUBE REPLACEMENT: UPDATING THE PROGRAM: USING THE SELECTION BUTTONS AND THE PROGRAMMING DISPLAY.
-
Page 4
“__61” IDENTIFICATION NUMBER “__62” DATE OF MANUFACTURE “__63” COUNTRY CODE “__64” NUMBER OF CONEXIONS OF THE COMPACT “__65” PROTOCOL PROGRAMATION “__66” NUMBER OF PRICES CONTROLLED BY THE COMPACT “__67” REPROGRAMMING A NEW COIN “__68” VERSION OF THE PROGRAMME “__70” A “__81” SALES COUNTS “__85”… -
Page 5: Working Condition
1- W ORKING CONDITION The compact can work between 0 ºC up to 60 ºC. 2- S YMBOL OF THE INSTRUCTION MANUAL This symbol indicates that there are more information in another point of this manual. è This symbol is in reference with programming. This symbol notices that the text is very important.
-
Page 6: T10 Validator
J-2000. NTRODUCTION TO MODEL The J-2000 validation group is an integrated system made up of an electronic coin validator and a refund system for automatic vending machines with MDB or Executive protocol. It consists of a electronic coin validator model T10, a 5 routes coin separator and five self loading change tubes.
-
Page 7: Refund Slide
Refund slide: This is the system that makes it possible to extract coins from the bottom of each change tube by a claw. It also has two safety locks to avoid the accidental falling of the coin in the tubes. Installation of the compact Verify that the compact is installed vertically and that the refund lever of the validator is not activated by the lever of the machine.
-
Page 8: Cleaning Of The Validator
Cleaning of the validator. Periodical cleaning of the walls and ramps of the validator, where the coins circulate, with a rag or damp cloth is recommended. Coin jams and tube replacement: order to disassemble the compact follow the next steps: — Unload completely the coins in the tubes.
-
Page 9
When you have made any changes , reassemble the compact in the reverse order, making sure you pass the flat cable of the slide through the plastic guide (4). 9 de 40 MNP11M01GB06 May 2007- Rev.4 Page:… -
Page 10: Updating The Program
Updating the program: IN COMPACT WITHOUT FLASH MEMORY: If it is necessary to update the program to a new version you have to replace the EPROM chip present in the control card. To do this you must move away the steel U, as is indicate in the previous figure.
-
Page 11: Using The Selection Buttons And The Programming Display
The J-2000 compact has two operating modes, the coin acceptance and refund mode and the program mode. In the first the compact is ready for the machine to carry out sales (sell mode), in the second the operating options of the J-2000 can be modified (program mode).
-
Page 12
— OFF: The J2000 is not receiving power. — EITHER ONE LIT: The J-2000 is receiving power but the VMC is not communicating with it. — ALTERNATING: The VMC is communicating. In sell mode the alternately flashing of the points of status of thousands, hundreds and tens tell of the state of the communication between the J-2000 and the machine. -
Page 13: Self- Check
Self- check: Each time that you return to sale mode from program mode, or when the compact is turned on, a self check procedure is started. If an error is detected the display will show the errors detected during 3 seconds, as a sequence of 1 2 of 3 depending the problem that is producing this error.
-
Page 14
4.- P ROGRAMMING ADDRESSES CCESS LEVELS Not all of the addresses of the programming mode are directly accessible, nor are they available in all models. They are divided into three access levels. To access the addresses of the second level a code must be introduced in address 50 (or address 60 if you want to get into the third level). -
Page 15: Maximum Refund / Maximum Credit
CREDIT “1101” to “1199” Nº OF VENDS FOR EACH PRICE When the J-2000 works in price retention, the number of sales made from each one of the prices can be consulted at these addresses. Each address has two fields: In field 1, pressing “3” the compact will show the number of partials vends for this price.
-
Page 16: X_22″ Coins Programmed Into The Tubes
..5_21: Nº of coins in tube 5. If we observe that the quantity is flashing on selecting a tube, this indicates that there is a possibility that the count does not coincide with the actual number of coins in the tube.
-
Page 17: Loading The Changers
Information is transmitted through the RS232C interface with a speed of 1200 or 110 baud. The RS232C interface is connected to a 400 mm, 4 line, screened cable that has a standard 9 Pin Sub — D connector. Printer J-2000 Colour Black White Ground…
-
Page 18: First Reload
FIRST RELOAD: If all the tubes are totally empty, when this address is reached the refund trolley will be placed in the middle left position and the only coins accepted will be those programmed to the 2,3 and 4 tubes. Each time that the count of coins in some of these tubes amounts to 3 coins, the slide will move removing the claw of the tube.
-
Page 19: Consulting And Resetting Breakdowns
Although its possible to do, it is not recommend to allow the compact in normal sale mode to have a tube with a number of coins less than the security level (3 coins). For this reason it is not recommended to completely unload any of the tubes. If a tube it’s totally empty it’s recommended to load to the security level through address 25.
-
Page 20
3_27: Photo-sensors of the tubes are covered: 1: Sensor of tube 1 is covered. 2: Sensor of tube 2 is covered. 4: Sensor of tube 3 is covered. 8: Sensor of tube 4 is covered. 16: Sensor of tube 5 is covered. Errors of this address will be self cleared when the sensor is uncovered. -
Page 21: Clock/Calendar
This address allows you to choose if the compact shows the price of the channel when there is no credit accumulated and the customer selects a product. You can also select if the J-2000 retains the prices or they were communicated by the vending machine controller whenever a sale channel is selected.
-
Page 22
1_30: This address determines which peripheral will be connected to the serial transmission network. The possible values are: 0: Only the machine controller (VMC). 1: The VMC and the Accountancy Unit (AU). 2: The VMC and the Card Reader (CPC). 3 : VMC, AU and CPC. -
Page 23: Automatic Unload Of Tubes
In the MDB protocol this address is used to program the existence of a recovery motor. Program “1” if the recovery motor is installed and a “0” if it is not. “__31” : AUTOMATIC UNLOAD OF TUBES This address allows to unload the tubes of the compact until a fixed coin level. To set the number of coins that will last on the compact tubes after doing a automatic unload you must program the fields “1_31”…
-
Page 24: Discount Sales
This number can change if the compact is running as MDB or Executive. “__42” DISCOUNT SALES The J-2000 allows the vending machine operator to offer the customer who uses the multiple sale, a discount on the price of the products purchased.
-
Page 25: Access Code For The Second Level
To access the second programming level the user must introduce the access code here. This code is a 4 digit number, introduced one by one. Once access is obtained, the J-2000 will light the decimal point corresponding to the units. In this situation this address allows the modification of the programmed code.
-
Page 26: Changing The Code
CHANGING THE CODE If we want to restrict the access to options of the compact (count data, coins programmed to tubes, etc.) we can program a new access code to the second level. To change the code press “3”. In this moment the display will show the code programmed at present.
-
Page 27: Inhibition Of Notes
The country code can be visualised (For Spain 0034). “__64” NUMBER OF CONEXIONS OF THE COMPACT It shows the number of times that the J-2000 has been switched on. This counter is cleared after obtaining a RS232 ticket if address 4_24 is programmed to a value of 1.
-
Page 28: Version Of The Programme
«2_XX» : total counts. If the compact is running under the MDB protocol only the marked (*) addresses will appear. The sales counts that the J-2000 carry out are the following: 70(*) : Money directed to interior change tubes. 28 de 40 MNP11M01GB06 May 2007- Rev.4…
-
Page 29: Total Number Of Sales
71(*) : Money directed to the deposit. It does not include the tokens. 72(*): Change refunded. 73(*): Change unloaded using address x_26 and address __31. 74 : Value of over payment. The sum of the money cancelled as a result of not being able to refund due to a lack of coins, or that value tokens have been used.
-
Page 30: Programming Summary
Programming summary: MDB EX 00: Maximum refund / maximum credit. 01 a 10: Price programming. 11 a 20: Nº of sales of each price. 21 : Number of coins in the changers. 22 : Coins programmed to tubes. 23 : Other coins programmed to tubes. 24 : Data outlet RS232C.
-
Page 31: Connections For The Executive Protocol
MOLEX 1625-9P Connector. Nº Colour Function Green White Grey Grey Shield MDB connections: The connections between the J-2000 compact and the VMC is made through a MOLEX 39-01-2060 connector. The connections are FRONT VIEW Colour Function Blue Black Ground —…
-
Page 32: Sizes Of Available Tubes
Sizes of available tubes. 32 de 40 MNP11M01GB06 May 2007- Rev.4 Page:…
-
Page 33
33 de 40 MNP11M01GB06 May 2007- Rev.4 Page:… -
Page 34: Safety Locks Size
Safety locks size. Not place in rubbish any electronic control board, because there are a lot of components that can be recyclable. Consult to the local authorities to obtain information on their recyclable. 34 de 40 MNP11M01GB06 May 2007- Rev.4 Page:…
-
Page 35: Trouble Shooting
The following description attempts to help to rectify the most common breakdowns in the coin changers. It describes a series of operating anomalies of the J-2000, the possible causes and the steps to follow to correct or to determine the cause of the same prior to contacting our service technician.
-
Page 36
Lamp burn out or a fault Check the continuity of does not light up. in the connection. the connection and the condition of the lamp. The J-2000 rejects a high Dirt in the measuring Clean the selector with a percentage of coins. In channel. impregnated… -
Page 37
NOTES: 37 de 40 MNP11M01GB06 May 2007- Rev.4 Page:… -
Page 38
38 de 40 MNP11M01GB06 May 2007- Rev.4 Page:… -
Page 39
39 de 40 MNP11M01GB06 May 2007- Rev.4 Page:… -
Page 40
Jofemar S.A. JOFEMAR RESERVES THE RIGHT TO INTRODUCE IMPROVEMENTS ARISING FROM ITS CONTINUOUS RESEARCH IN THIS MODEL WITHOUT PRIOR NOTICE 40 de 40 MNP11M01GB06 May 2007- Rev.4 Page:…
Перезагрузка монетника
Первое что нужно сделать — опустошить монетник, т.е. сбросить из него все монеты: 26 функция (кнопка 2 — 3 — 2_)
Далее нужно перезагрузить монетоприемник:
1. Выключаем автомат
2. Жмем кнопку 4 и удерживая ее включаем автомат
3. Ждем пока протестируется автомат, дольется вода
4. Другой рукой нажимаем кнопку 2, удерживая кнопу 4
5. Опускаем кнопку 4, потом отпускаем 2
На монетоприемнике должна пробежать буква С
Далее необходимо загрузить монеты (25 функция):
— засыпать три 1-рублевых монеты (подождать немножко)
— засыпать три двушки (подождать немножко)
— засыпать три пятака (подождать немножко)
После этих манипуляций услышим характерное ням-ням — автомат разравнивает монеты в тубах.
— После этого уже загрузить все остальные монеты в произвольном порядке
Если у вас не принимаются монеты: при пролетании монеток через монетоприемник — смотрим на табло монетника -если высвечивает
1 – запрет приема автоматом
2 – не могу распознать
3 — распознал и приянял
Если почему то перестал выдавать сдачу и перезагрузка не помогла:
Зайдите в меню (третий уровень доступа) и найдите функция Maximum Refund (кажется так) — максимальная сдача — значение должно быть в диапазоне 50-100
Сброс, выгрузка, программирование и заполнение монетоприёмника Jofemar J2000-1. ВидиоинструкцияПодробнее
Разгрузка монетоприемника J2000 JofemarПодробнее
Загрузка монет J2000 Jofemar #кофе #кофеавтомат #кофемашина #вендингПодробнее
Сброс ошибки монетника без перезагрузки до заводских кофе аппарата Джофемар (Jofemar) G500/250/546Подробнее
Не работает мотор выдачи монет Монетоприёмника Jofemar J-2000Подробнее
Ошибка Ящик с отходами полный. Jofemar.Подробнее
Калибровка купюроприемника Jofemar ВидиоинструкцияПодробнее
дозировка зерна и положение поршня jofemarПодробнее
Jofemar J2000 (sacar monedas en dirección 26)Подробнее
Застряли монеты в монетоприёмнике; Ошибка монетоприёмника; Ремонт монетоприёмникаПодробнее
Выгрузка монет из монетоприемника Jofemar G546, g250Подробнее
Jofemar G-250, G-500, Bluetec. Ошибка «заберите стакан»Подробнее
События
Ссылки и html тэги не поддерживаются
Комментарии:
André — 02.06.2023 00:24
привет, один 0 вместо двух 0 ошибка? Спасибо
Ответить
Лёва — 01.11.2022 12:03
у меня почему-то на всех J2000 c T15 валидатором нет во втором уровне программирования пункта с номером 23. не могу запрограммировать вторую монету! может затёрли при заливке основной программы?
кто знает подскажите.
Ответить
Мухаммад Али — 15.02.2022 07:12
В 7ечейки ошибка .. 30
Ответить
Помогите монетоприемник не принимает монеты пишет на дисплеи 0 .Что делать ? JOFEMAR J-2000-1
Скачайте фото-инструкцию Обслуживание G250\546 18,3 мб — https://yadi.sk/i/Xq_jBSOeejRsc
Обслуживание монетоприемника стр.62
ПОЛНАЯ РАЗГРУЗКА МОНЕТ:
На монетоприемнике
нажать 2 — на дисплее монетоприемника 26
нажать 3 — на дисплее монетоприемника — — — —
нажать и удерживать 2 пока не разгрузятся все монеты.
нажать 4 для выхода в рабочий режим — на дисплее бегающие точки.
Если разгрузка не происходит — выгрузить все монеты вручную разобрав тубы по фото-инструкции.
ПЕРЕБРАТЬ СОРТИРОВЩИК по инструкции, убрать застрявшие монеты и посторонние предметы, продуть прочистить , проверить целостность зубьев шестерни редуктора каретки. Собрать обращая внимание на обозначение верх\низ туб (см. инструкция стр.67)
ПОЛНОЕ ОБНУЛЕНИЕ (тубы должны быть полностью разгружены, опция 26) аппарат выключен.
1. при нажатой на монетоприемнике кнопке 4 — включить аппарат
2. не отпуская 4 нажать 2
3. не отпуская 2 отпустить 4
4. отпустить 2 — на дисплее монетоприемника должна мигнуть буква С это значит обнуление произошло, если нет — повторить еще раз.
ПЕРВАЯ ЗАГРУЗКА ДОЛЖНА ПРОИЗВОДИТЬСЯ строго по инструкции стр.69
Если монета направляется не в ту тубу, которая для нее предназначена, проверьте или измените конфигурацию туб стр.70.
Ошибки расшифровываются в опции 27 монетоприемника см. руководство для J2000.
Затем загрузить монеты для сдачи через меню аппарата МЕНЮ ОПЕРАТОРА – ЗАПОЛНЕНИЕ ТУБ монеты загружаются в любом порядке.
Для приема банкнотоприемником купюр всех номиналов требуется наличие в тубах сдачи в сумме больше 350 руб.
Иногда при сбросе монетоприемника слетает параметр «Базовая монета» при этом сдача начинает выдаваться частями, после нажатия кнопки «возврат денег». Проверить\изменить параметр «Базовая монета» стр.71
Если эти мероприятия не дали положительного результата необходимо отправить монетоприемник в Сервисный центр для ремонта — http://www.vavilon-vending.ru/support/
Сброс, выгрузка, программирование и заполнение монетоприёмника Jofemar J2000-1. ВидиоинструкцияПодробнее
Сброс ошибки монетника без перезагрузки до заводских кофе аппарата Джофемар (Jofemar) G500/250/546Подробнее
Разгрузка монетоприемника J2000 JofemarПодробнее
Загрузка монет J2000 Jofemar #кофе #кофеавтомат #кофемашина #вендингПодробнее
Не работает мотор выдачи монет Монетоприёмника Jofemar J-2000Подробнее
Выгрузка монет из монетоприемника Jofemar G546, g250Подробнее
Застряли монеты в монетоприёмнике; Ошибка монетоприёмника; Ремонт монетоприёмникаПодробнее
Ошибка Ящик с отходами полный. Jofemar.Подробнее
Калибровка купюроприемника Jofemar ВидиоинструкцияПодробнее
G-23, ошибка запуска кофе группы,ошибка позиции кофе группы.Подробнее
Jofemar G-250, G-500, Bluetec. Ошибка «заберите стакан»Подробнее
дозировка зерна и положение поршня jofemarПодробнее
Новости
Разгрузка монетоприемника J2000 JofemarПодробнее
Загрузка монет J2000 Jofemar #кофе #кофеавтомат #кофемашина #вендингПодробнее
Проверка и сброс ошибок J2000 JofemarПодробнее
Не работает мотор выдачи монет Монетоприёмника Jofemar J-2000Подробнее
Калибровка купюроприемника Jofemar ВидиоинструкцияПодробнее
j2000-J-Home Настройка, программированиеПодробнее
Сброс ошибки монетника без перезагрузки до заводских кофе аппарата Джофемар (Jofemar) G500/250/546Подробнее
Выгрузка монет из монетоприемника Jofemar G546, g250Подробнее
Монетоприёмник (Настройки-программирование монетоприёмникаПодробнее
Застряли монеты в монетоприёмнике; Ошибка монетоприёмника; Ремонт монетоприёмникаПодробнее
Загрузка монет в монетоприемник Jofemar G546Подробнее
Загрузка монет в Aquatic Bar и маленькие проблемки с монетоприёмникамиПодробнее
монетоприемник обучение приема монет!!!Подробнее
Не принимал монеты. Программирование. Чистка.Подробнее
Загрузка монет в монетоприёмник Cashflow 690 | вендинг |Подробнее