OPERATION MANUAL
OPERATION MANUAL
MITSUBISHI TRANSPORT REFRIGERATION UNIT
TU85SAE
This operation manual is
intended to provide users
with a good knowledge to
use Mitsubishi Refrigeration
Unit safely.
Operate or service the
refrigeration unit only after
you have read this manual
and understand its
contents.
Carefully store this manual
in a xed place so that it is
immediately available for
your reference when you
need it.
TSJ012A204A
YEAR:2016
Summary of Contents for Mitsubishi Heavy Industries TU85SAE
Alarm
Trouble
Code
Magnet clutch
fuse has blown.
Throttle solenoid
fuse has blown.
Load drive circuit
fuse has blown.
Commercial power
supply is defective.
High pressure
protection device
tripped.
Discharge gas temperature
is abnormally high.
Refrigerant
shortage.
Low-pressure is abnormally
low or abnormal
low-pressure sensor .
Abnormal
high-pressure sensor.
Engine cooling
water tempera-
ture is abnormally
high.
Engine speed is
abnormally low.
Engine start
failure.
Engine speed is
abnormally high.
Condensing unit
front panel open.
Motor over-current
protection device
tripped.
Poor alternator
generation.
Evaporator electric
heater protection device
tripped. (Optional)
Engine clutch overheat
protection device tripped.
*This alarm cannot be reset because it could result in a fire. When this alarm has occurred,
contact a dealer.
Countermeasure
Fuse F3 has blown. Replace fuse F3 (10 A) in the
control box. If trouble persists after replacement,
ask a dealer for inspection.
Fuse F9 has blown. Replace fuse F9 (30 A) in the
control box. If trouble persists after replacement,
ask a dealer for inspection.
Fuse F2 has blown. Replace fuse F2 (15 A) in the
control box. If trouble persists after replacement,
ask a dealer for inspection.
Commercial power supply is in failure or
disconnected. Check the power supply.
High-pressure switch has tripped.
(1) Open the front panel and inspect the condenser
fan drive system for any abnormality.
(2) Check to see if the condenser coil is fouled
heavily. If so, cleanse it with water.
(High-pressure cleansing is prohibited.)
Refrigerant temperature at the compressor discharge side
has reached the protective temperature. Consult a dealer.
Refrigerant quantity is extremely low.
Ask a dealer for inspection.
Refrigerant pressure at compressor suction side has
dropped to the protective pressure, or low-pressure sensor
is in failure. Ask a dealer for inspection.
High-pressure sensor is in failure.
Ask a dealer for inspection.
Engine water temperature switch has tripped. Inspect the
water quantity in the reservoir tank and replenish if
necessary. Also inspect and clean the radiator (heat
exchanger placed at right as seen facing the refrigeration
Engine speed is extremely low.
Ask a dealer for inspection
Inspect the fuel tank to see if fuel is reserved.
If fuel is reserved, inspect the battery.
Engine speed has increased far beyond the
setting value. Ask a dealer for inspection.
Front panel of condensing unit is open. Close
the panel completely.
Motor over-current protection device has
tripped. Ask a dealer for inspection.
Power generation signal from the alternator is not
detected. When the unit operation has been stopped
due to this error, ask a dealer for inspection.
Electric heater protection device has tripped.
Ask a dealer for inspection.
Engine clutch overheat prevention device has tripped.
Ask a dealer for inspection.
— 68 —
9 For emergency
Alarm
Unit
Lamp
Condition
On
Unit stops.
Unit operation continues.
(Emergency
Blinking
operation with low
engine speed only)
On
Unit stops.
Unit stops.
Blinking
(Automatic operation
resume)
On
Unit stops.
Unit stops.
Blinking
(Automatic operation
resume)
Unit stops.
On
On
Unit stops.
Blinking
Unit stops.
On
Unit stops.
Unit stops.
(Automatic operation
On
resume repeats up
to 9 times.)
Unit stops.
On
On
Unit stops.
Unit stops.
Blinking
(Automatic operation
resume)
Unit stops.
(Automatic operation
On
resume repeats up
to 2 times.)
Blinking
Unit operation
(or On with
continues.
battery
(Unit stops if battery
voltage drop)
voltage is low.)
Unit stops.
(Automatic
Blinking
operation
resume)
Unit* stops.
On
1
2
3
4
5
6
7
8
9
1 0
Позвони на ближайший сервис термокинг или карер ..может они по телефону подскажут
Если брать по термокингу то похоже проблема в батарейке…еще ремень на генератор нужно смотреть
Андрей Алтынов
25.09.2017
В термо кинге есть такая кнопочка (=), держишь ее на выбитой ошибке несколько секунд, она ее обнуляет и запускает двигатель. Распространенные причины ( плохое топливо, топливо не поступает, проблема с насосом, воздух в топливной системе, проблема с заслонкой, недостаточное количество антифриза в системе охлаждения) и самый плохой вариант — это приходит конец плунжерам в ТНВД… !
Александр Новиков
25.09.2017
Спасибо, уже разобрались, радиатор забит был, промыли, ошибку скинули, все гуд. Просто никогда с мицубиши не работал
Table of Contents for Mitsubishi Heavy Industries TU85SAE:
-
— 18 — 3 Precaution for safety 1 5 2 6 3 7 9 4 8 10 ● When swallowing compressor oil Do not throw up the oil by force and consult a physician as soon as possible. When inside the mouth is contaminated, wash it well with water. (When throwing up the oil by force, it easily gets into air passage and causes high fever if it gets into lung. It may cause hardly incurable hemorrhagic pneumonia accordingly.) (3) Antifreeze coolant ● When antifreeze coolant got in your eye Wash your eye with lots of clean run
-
— 38 — 5 Operation 1 5 2 6 3 7 9 4 8 10 Operation 1 WARNING Confirm that the front panel of condensing unit is closed before starting operation. • It may cause accidents if the operation is attempted with the panel opened. (See NOTE below.) 1 Press the [RUN/STOP] switch. (Refrigeration unit is turned «ON».) ⇒ Inside container temperature and setting temperature are displayed on the LCD display. Commercial power supply icon lights when the unit is driven by the motor. Warning buzzer sounds bef
-
— 26 — 4 Initial setting 1 5 2 6 3 7 9 4 8 10 DOWN switch UP switch LCD backlight setting mode DOWN switch UP switch Buzzer sound setting mode Whisper operation setting mode DOWN switch UP switch DOWN switch UP switch Operation log interval setting mode In-stop log interval setting mode • When it is necessary to change the setting of LCD backlight, buzzer sound or logging interval, consult your nearest dealer. DOWN switch UP switch Option selection setting mode UP switch DOWN
-
— 60 — 7 Inspection 1 5 2 6 3 7 9 4 8 10 Periodic inspection Please ask your nearest dealer to perform periodic inspection to ensure to use the refrigeration unit in the best condition all the time. Periodic inspection consists of the following items. 1. Inspection at every 1000 hours 2. Inspection at every 3000 hours 3. Inspection at every 9000 hours Check the contents of inspection with the check sheet submitted after the periodic inspection.
-
— 11 — 3 Precaution for safety 1 5 2 6 3 7 9 4 8 10 Precautions General precautions DANGER Do not modify or perform specification change for the refrigeration and vehicle. (This will make refrigeration unit out of warranty.) • It may cause a serious accident if customer modify the refrigeration unit or change the specification by himself/herself. Do not paint on resinic design panel. (This will make refrigeration unit out of war
-
— 29 — 4 Initial setting 1 5 2 6 3 7 9 4 8 10 Setting the defrost interval timer 1 2・4 3・5 1 Press the [MODE] switch. ⇒ The display changes to the «Clock/calendar display mode». 2 Press the [UP] or [DOWN] switch until the display changes to the «Defrost interval timer setting mode». (Right figure) 3 Press the [SET] switch. ⇒ Time starts to blink on the lower digital display. Icons and starts to blink. 4 �
-
— 22 — 4 Initial setting 1 5 2 6 3 7 9 4 8 10 Mode displays and functions Pressing the [MODE] switch once on the «Normal display screen» while the refrigeration unit is stopped or operating, the display changes to the «Clock/ calendar display mode». Each press on the [UP] or [DOWN] switch changes the display, allowing doing different settings. In the flowing figure, the [DOWN] switch progresses the changes whil
-
— 6 — 2 Name of each part 1 5 2 6 3 7 9 4 8 10 Cabin controller 1 6 7 8 2 3 4 5 1 RUN/STOP switch Starts or stops the refrigeration unit. 2 MODE switch Selects the normal display screen or the setting display screen. Displays the screen while the refrigeration unit is stopped. 3 UP switch Changes the setting temperature, setting screens and setting values. 4 DOWN switch Changes the setting temperature, setting screens and setting values. 5 SET switch Registers the se
-
— 45 — 5 Operation 1 5 2 6 3 7 9 4 8 10 Setting the OFF timer 1 2・4・6・8 3・5・7・9 1 Press the [MODE] switch. ⇒ The display changes to the «Clock/calendar display mode». 2 Press the [UP] or [DOWN] switch until the display changes to the «OFF timer setting mode». (Right figure) 3 Press the [SET] switch. ⇒ » » or » » starts
-
— 7 — 2 Name of each part 1 5 2 6 3 7 9 4 8 10 Digital display area 1 6 2 5 4 3 Explanation of display 1 Upper digital display Displays the setting temperature during operation. 2 Lower digital display Displays the inside container temperature during operation. 3 Temperature symbol °C will light in case of centigrade and °F will light in case of Fahrenheit. (Initial setting is in centigrade.) 4 Function icons Either one of these icons will light when corresponding function is selected. Display for printer. The lamp blink
Questions, Opinions and Exploitation Impressions:
You can ask a question, express your opinion or share our experience of Mitsubishi Heavy Industries TU85SAE device using right now.
-
05.10.2020, 06:05
#1
Новичок
Mitsubishi TU-85 загадка с давлением
Доброго дня, коллеги!
ХОУ Mitsubishi TU-85, пришла по замене радиаторов конденсатора. Кондесоры заменили, отвакумировали и заправили по мануалу. При запуске ХОУ отрубается по «высокому», причем на сервисном порту до конденсатора (см. рисунок) давление нарастает, а после ресивера нет. На «тепло» работает нормально.
Я сно, что гле то «затык»- разобрали всю магистраль, продули-все дуется, ничего постороннего нет. Собрали- та же ситуация. подкинули с рабочей ХОУ клапан SV4- изменений нет.
Выпаяли клапан, стоящий на магистрали перед конденсатором и заменили его на новый- ХОУ заработала.
Ради интереса распилили демонтированеый клапан — там нет запортного элемента- то есть это просто трубка! Скорее всего шарик вылетел ранее и остался в страых радиаторах конденсатора, так как мы магистраль продували весьма тщательно.
Но тогда ЧТО создавало «затык» и не давало проходить фреону?
М.Б. у кого есть какие то предположения или с таким уже сталкивались?
-
11.01.2023, 12:56
#2
Новичок
Воздух в системе по моему может влиять на высокое давление.. Может плохо провакумировали или при заправки косеканули.. Имхо.
-
12.01.2023, 19:12
#3
Местный
Это просто обратный клапан,туда дуй-обратно …Обогрев,оттайка работают по другому, потому и шло.Сам же схему выложил.Если ты ее ремонтируешь то должен знать,чего куда идёт.
-
14.01.2023, 00:27
#4
Местный
Сообщение от «Александр
Воздух в системе по моему может влиять на высокое давление.. Может плохо провакумировали или при заправки косеканули.. Имхо.
а еще неплохо даты смотреть перед тем, как отвечать!!!
-
14.01.2023, 00:27
#5
Местный
Сообщение от kop
Это просто обратный клапан,туда дуй-обратно …Обогрев,оттайка работают по другому, потому и шло.Сам же схему выложил.Если ты ее ремонтируешь то должен знать,чего куда идёт.
аналогично!
-
24.01.2023, 17:59
#6
Новичок
Сообщение от vegapiratr
а еще неплохо даты смотреть перед тем, как отвечать!!!
Так люди то и старые темы читают . И некоторым как мне к примеру интересно и мнение и решение вопросов не зависимо от срока давности.
Социальные закладки
Социальные закладки
-
Google
Ваши права
- Вы не можете создавать новые темы
- Вы не можете отвечать в темах
- Вы не можете прикреплять вложения
- Вы не можете редактировать свои сообщения
- BB коды Вкл.
- Смайлы Вкл.
- [IMG] код Вкл.
- [VIDEO] код Вкл.
- HTML код Выкл.
Правила форума