Answer #1: Posted by freginold on September 21st, 2015 8:22 AM
This answer was accepted by the poster of the original question.
freginold
Member since:
December 20th, 2011
Points:
23,240,715
1,100
points
Hello, sounds can be very hard to troubleshoot on a copier without being able to physically hear them. However, here are some tips that may help:
— If the sounds only occur when copying/printing, try cleaning the rollers in the area where the sound is coming from. If you’re not sure how to clean them, just use a damp cloth or lint-free rag. If you have compressed air, also clean the bearings and bushings on the feed shafts.
— If it sounds like a clicking noise, then it could be a bad bearing in the fusing unit.
— If it sounds like a very rapid clicking, it could be a chipped gear.
— If it is a high-pitched squeal or squeak, it could be dirty rollers or a dirty bushing.
Fax System (W) Operation Guide Rev-2.2013.1 — Page 209
… Setting
Click [FAX TX Setting] to set the original size and other transmission conditions.
1 Display the screen. 1 From the start button, click [Control Panel], [Hardware and Sound], and [Devices and Printers]. 2 Right-click the product name of the machine you are using and select [Printing preferences] from the pull-down list.
Item
Description
Original Size…
Kyocera Net Viewer Operation Guide Rev 5.3 2013.06 — Page 47
… list. Network Groups List
The device display name and IP address appearing in the title at the top of the Network Groups dialog box represent the selected device. The columns in ascending or… contains up to 20 groups, plus the Other group which is selected by the application. Device
Network Groups
You can be resized horizontally and vertically, minimized, maximized, or restored. For …
PRESCRIBE Commands Technical Reference Manual — Rev. 4.9 — Page 219
…the lower left UR: upper right
Device-Control Instructions
KC-GL uses device-control instructions to return buffer …appear in DeviceControl Instructions on the parallel interface. If device-control instructions are received via the RS-232C interface.
Output Extended Status (ESC.O)
This instruction returns printing system status information regarding:
• On-line status • Cover…
Printing System (11),(12),(13),(14) Color Printing Guide (Fiery E100) — Page 8
… E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP,…Topics for which additional information is available by starting Help in bold, for example, output profile, that appear throughout this document. A caution concerning operations that may lead to death or injury to persons if not…
Printing System (11),(12),(13),(14) Configuration and Setup Guide (Fiery E100) — Page 8
Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP, Windows Vista, Windows 7, Windows Server 2003/2008/2008 R2 Topics for which …
Printing System (11),(12),(13),(14) Utilities Guide (Fiery E100) — Page 6
…
This document uses the following terminology and conventions. Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this document refers you to Help for additional information and explains how to access Help for which…
Printing System (11),(12),(13),(14) Printing Guide (Fiery E100) — Page 8
…
This document uses the following terminology and conventions.
Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP, Windows Vista, Windows 7, Windows Server 2003/2008/2008 R2 Topics for which…
Setup Tool Operation Guide Rev-1 — Page 42
…-1024MFP and FS-1124MFP are not supported.
• In the edit dialogs of Device Accounting Settings and Account List, default values are automatically set when a file is not set …the copy counter setting of the address book cover page is grayed out and the contents cannot be changed.
• Data can be…-3050, KM-4050, KM-5050, and TASKalfa 300i.
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 50
…in the other section of this machine, the label is safe to the laser unit is cut off when the right cover is invisible. The label shown …Devices and Radiological Health (CDRH) of laser products in 1968. Safety of laser beam
This machine has been certified by the manufacturer to the laser beam, which is opened.
1-6 This indicates that the product is on the right.
3051ci
3551ci…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 52
…’s exclusive remedy shall be replacement of any other rights, which are not genuine KYOCERA brand parts or …(d) have no obligation to furnish labor. This warranty covers Maintenance Kits and the components of Maintenance Kits included …Information > Notice
Warranty (the United States and Canada)
3051ci / 3551ci / 4551ci / 5551ci MULTIFUNCTIONAL PRODUCT LIMITED WARRANTY
KYOCERA Document Solutions…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 60
…resources. Sleep
The device automatically enters Sleep when 30 minutes (for 3051ci), 45 minutes (for 3551ci), or 60 minutes (for 4551ci or 5551ci) have passed since the device was last used … be used . It is recommended that automatically activates energy-saving mode when the machine is equipped with the device within a set to further saving of no activity that recycled as well as …
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 68
… (Option)
Network Network
TWAIN Scanning WIA Scanning
TWAIN and WIA are using the machine with a network cable (1000BASE-T, 100BASE-TX or 10BASE-T)
Administrator’s PC
Command … for communication between software applications and image acquisition devices. Optional Network (page 8-47)
2-6 Installing and Setting up the Machine > Determining the Connection Method and Preparing Cables
…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 170
…
1 Click [Start] button on the Windows, and then click [Devices and Printers]. 2 Right-click the printer driver icon of the machine, and click the [Printer properties] menu of
the printer driver. … the taskbar at the bottom right of the screen and then click the item you want to [Black] and click [OK]. The following :
NOTE When canceling printing from this machine, refer to Canceling Jobs on…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 344
Model Name 3051ci 3551ci 4551ci 5551ci
Login User Name 3000 3500 4500 5500
Login …
User Name
Result Completed
Completed
Completed
1/1
Error
Completed
Detail
Printing Jobs
Sending Jobs
Storing Jobs
Device/ Communicate
Paper/ Supplies
Close
NOTE
If the user authentication screen appears, enter your login user name and login password and press [Login]. Press the [Status/Job…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 349
… such as waiting or printing are displayed. • Press [Format] to this machine or check their status.
1 Display the screen.
1 Press the [Status/Job Cancel] key.
2 Press [Device/Communicate].
Line Off
Device/ Communicate
i-FAX
Paper/ Supplies
Check New FAX Close
The screen to this machine are displayed.
«Removable Memory (USB Memory)» • The usage and capacity…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 391
… to [On]. NOTE
If the user authentication screen appears, enter your login user name and login password and press [Login]. Set the subject automatically entered when sending device log histories by E-mail. The factory default login user name and login password are sent.
Model Name 3051ci 3551ci 4551ci 5551ci
Login User Name 3000 3500…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 407
…machine enter a sleep state immediately after printing to check the machine memory.
* Displayed only when the optional FAX Kit is selected, it to return it may appear on the machine…machine maintenance. Adjust copy density. Adjustment can be made in 7 levels.
Adjustment can be made in 7 levels. It takes 331 seconds on 3051ci, 282 seconds on 3551ci… the operating sound is done….
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 571
… 8-39 Reserve Next 5-23 Reserved copy 5-23 Resolution 6-69, 11-25, 11-26 Responding to Messages 10-24 Restart Entire Device 8-52 Restart Network 8-46 Right Cover 1 Lever 2-3 Right Cover 2 2-3 Right Cover 2 Lever 2-3 Right Cover 3 Lever 2-3 Right Job Separator 11-6
S
Safety Conventions 1-2 Safety Conventions in This Guide 1-2 Saturation 6-31 Scan Resolution
Default 8-17 Security Level 8-49 Send…
TASKalfa 3051ci/3551ci/4551ci/5551ci Printer Driver User Guide — Page 2
…TASKalfa 3551ci TASKalfa 4551ci TASKalfa 5551ci
© 2013 KYOCERA Document Solutions Inc. and/or other countries. Adobe®, Acrobat®, Adobe Reader®, Photoshop® and PostScript® are registered trademark of Apple Inc. KPDL is a trademark of Hewlett-Packard Company. User Interface screen…guide is a trademark in the United States and other countries, licensed …
TASKalfa 3051ci/3551ci/4551ci/5551ci Printer Driver User Guide — Page 46
… the feature under Available controls, and click the right arrow to move the feature to Selected controls. Windows 7 and Windows Server 2008 R2: click Start, and then click Devices and Printers.
To use that profile to print the same type of driver features to appear in the Quick Print tab.
1 Depending on the…
Если с аппаратом Kyocera TASKalfa 1800, Kyocera TASKalfa 2200 произошла проблема, откроется следующий экран с уведомлением.
• Индикатор [Внимание] на панели управления горит или мигает.
• На дисплее сообщений панели управления аппарата появилось сообщение об ошибке.
Если индикатор [Внимание] горит или мигает и на дисплее сообщений панели управления аппарата появилось сообщение об ошибке, проверьте KYOCERA Client Tool или Монитор состояния.
ПРИМЕЧАНИЕ Если индикаторы постоянно горят и мигают не так, как описано выше, вероятно, произошла ошибка службы. Выключите питание, отсоедините шнур питания и вставьте его обратно, после чего включите питание. Это может помочь сбросить ошибку. Если ошибка не исчезает, свяжитесь со своим представителем сервисной службы (тел. в Минске +375 17 291-28-24)
Ниже описаны неполадки, которые не могут быть устранены пользователем
Дисплей сообщений |
Описание |
Меры устранения |
Бункер отраб тонера перепол. или не уст. |
Бункер для отработанного тонера установлен неправильно |
Установите Бункер для отработанного тонера должным образом |
Бункер для отработанного тонера заполнен |
Замените бункер отработанного тонера |
|
Встряхните картр. с тонером |
Тонер слежался |
Откройте переднюю крышку аппарата и вытяните контейнер с тонером. Сильно встряхните контейнер с тонером и установите его на место |
Вызовите сервисный персонал. |
В аппарате произошла ошибка |
Обратите внимание на код ошибки, отображаемый в дисплее сообщений, и свяжитесь с представителем сервисной службы (тел. в Минске +375 17 291-28-24) |
Выньте бумагу с внутреннего лотка |
Извлеките бумагу из внутреннего лотка. Нажмите клавишу [OK], чтобы возобновить печать |
|
Добавьте тонер |
Закончился тонер |
Замените контейнер с тонером TK-4105 |
Загрузите бумагу в кассету # |
↑↓ (отображается попеременно) |
Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.] |
Загрузите бумагу в универсальный лоток |
↑↓ (отображается попеременно) |
Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.] |
Закройте автоподатчик оригиналов |
Открыт автоподатчик оригиналов |
Откройте и закройте автоподатчик оригиналов |
Закройте крышку автопод. оригиналов |
Открыта верхняя крышка автоподатчика оригиналов |
Откройте и закройте крышку автоподатчика оригинало |
Закройте переднюю крышку |
Открыта передняя крышка |
Откройте и закройте переднюю крышку |
Закройте правую крышку # |
Открыта какая-либо крышка |
Откройте и закройте крышку, обозначенную на экране |
Замятие бумаги. (DP) |
В автоподатчике произошло замятие бумаги. |
См. Устранение замятия бумаги в Руководстве по эксплуатации и извлеките замятую бумагу |
Замените МК |
Необходимо производить замену деталей комплекта техобслуживания MK-4105 (ремкомплекта) каждые 150 000 страниц печати. |
Данная операция должна производиться специалистом. Обратитесь к представителю сервисной службы (тел. в Минске +375 17 291-28-24) |
Замятие |
Произошло замятие бумаги в кассете или универсальном лотке |
См. Устранение замятия бумаги и извлеките замятую бумагу |
Извлеките оригиналы из автоподатчика |
Для продолжения работы необходимо извлечь оригиналы из автоподатчика оригиналов |
Извлеките оригиналы из автоподатчика оригиналов |
Кабель USB был отключен |
Кабель USB не подключен |
Нажмите клавишу [OK] и подключите кабель USB |
ПК выключен |
Нажмите клавишу [OK] и включите ПК |
|
Не удается найти KYOCERA Client Tool |
Нажмите клавишу [OK] и откройте KYOCERA Client Tool на ПК |
|
Макс. к-во сканируемых страниц |
Превышен предел сканирования |
Дальнейшее сканирование невозможно. Задание отменено. Нажмите клавишу [OK] |
Мало тонера. (Зам., когда законч.) |
Скоро понадобится заменить контейнер с тонером |
Получите новый контейнер с тонером TK-4105. |
Не оригинальный тонер |
Установлен контейнер с тонером не марки Kyocera |
Производитель не несет ответственности за повреждения, вызванные использованием неоригинального тонера. Мы рекомендуем использовать исключительно оригинальные контейнеры с тонером TK-4105. . |
Неверный ид. уч. зап. Задание отменено |
Указан неверный идентификатор учетной записи при внешней обработке задания. Задание отменено |
Нажмите клавишу [OK] |
Невозможна двусторонняя печать на этой бумаге |
Не возможна печать на бумаге выбранного формата или типа |
Нажмите клавишу [OK] и перейдите к следующему шагу: |
Недостаточно памяти. Невозможно начать выполнение задания |
Невозможно начать выполнение задания |
Повторите попытку позже |
Ограничено алгоритмом учета заданий(Печать) |
Задание отменено, поскольку его выполнение ограничено функцией учета заданий |
Нажмите клавишу [OK] |
Ограничено алгоритмом учета заданий(Сканер) |
Задание отменено, поскольку его выполнение ограничено функцией учета заданий |
Нажмите клавишу [OK] |
Очистите сканер |
Произошло загрязнение сканера |
Очистите щелевое стекло с помощью чистящей салфетки, поставляемой вместе с автоподатчиком оригиналов. |
Ошибка. Выключить |
— |
Отключите и снова включите аппарат с помощью выключателя питания |
Память переполнена |
Невозможно продолжить выполнение задания из-за отсутствия свободной памяти |
Измените разрешение печати с Быстр1200 до 600 dpi. См. Printer Driver User Guide |
Память сканера переполнена |
Дальнейшее сканирование невозможно из-за нехватки памяти сканера. |
Для отмены задания нажмите [OK] |
Перезагрузка печати. Задание отменено |
Предупреждение. Недостаточно памяти принтера. Задание отменено |
Нажмите клавишу [OK] |
Превышено ограничение учета заданий |
Превышено число распечаток из-за ограничения алгоритмом учета заданий. Достигнут предел печати |
Это задание отменено. Нажмите клавишу [OK] |
Уст.другую кассету |
Выбрано «Сдвиг» |
Для использования сдвига необходимо загрузить в другой лоток бумагу такого же формата, что и в выбранном устройстве подачи, но в другой ориентации |
Установите все оригиналы обратно и нажмите клавишу [Старт]. |
Возникает при печати двусторонних документов в режиме ручной двусторонней печати |
Извлеките оригиналы из автоподатчика оригиналов, расположите их в первоначальном порядке и положите обратно. Нажмите клавишу [OK], чтобы возобновить печать. Для отмены задания нажмите [Стоп] |
Установлен неизвестный тонер. ПК |
Региональная спецификация контейнера с тонером не соответствует спецификации аппарата |
Установите оригинальный контейнер с тонером Замените контейнер с тонером TK-4105 |
Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.
В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.
Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.
Код ошибки Описание ошибки Причина ошибки 0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. 0070 FAX control PWB incompatible detection Error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. FAX control PWB (The FAX PWB installed will not be the one designed for the machine. 0100 Backup memory device error EEPROM (Control PWB) 0120 MAC address data error
For data in which the MAC address is invalid. EEPROM (Control PWB) 0130 Backup memory read/write error (main NAMD) Flash memory (Control PWB) 0140 Backup memory data error (main NAND) Flash memory (Control PWB) 0150 Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM. 0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Defective PWB. 0180 Machine number mismatch
Machine number of control does not match. Data damage of EEPROM. 0600 Expanded memory (DIMM) installing error
The expansion memory modules (DIMM) are not correctly mounted. Improper installation expanded memory (DIMM). 0610 Expanded memory (DIMM) error
The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly. Defective expanded memory (DIMM). Defective main PWB. 0640 Hard disk error
The hard disk cannot be accessed. Defective hard disk. Defective main PWB. 0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB. Defective FAX software. Defective FAX control PWB. 0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Defective main PWB. 0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Defective FAX control PWB or main PWB. 0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. 0930 EEPROM bus error Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB. 1010 Lift motor error
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB. 1020 PF lift motor error (paper feeder 1)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1030 PF lift motor error (paper feeder 2)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1500 PF heater 1 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1510 PF heater 2 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1520 PF heater 1 high temperature error (paper feeder 2)
A temperature higher than 75aC/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1530 PF heater 2 high temperature error (paper feeder 2)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1600 PF heater 1 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1610 PF heater 2 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1620 PF heater 1 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1630 PF heater 2 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1800 Paper feeder communication error
Communication error between engine PWB and optional paper feeder. Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB. 2100 Developing motor error
The developing motor ready input is not given for 5 s during the main motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB. 2200 Drum motor error
The drum motor ready input is not given for 5 s during the drum motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB. 2330 Fuser pressure release motor error
When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2340 Fuser pressure release motor time-out error
When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2500 Paper feed motor error
The drum motor ready input is not given for 5 s during the paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB. 2600 PF paper feed motor error (paper feeder 1)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB 2610 PF paper feed motor error (paper feeder 2)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB. 2730 Developing release motor error
When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2740 Developing release motor time-out error
When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2820 Fuser motor error
The fuser motor ready input is not given for 5 s during the fuser motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB. 3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB. 3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3300 AGC error
After AGC, correct input is not obtained at CCD. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3500 Communication error between scanner and ASIC
An error code is detected. Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB. 4001 Polygon motor KM error
The polygon motor KM ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor KM. Defective engine PWB. 4002 Polygon motor CY error
The polygon motor CY ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor CY. Defective engine PWB. 4201 Laser output error (black)
The pin photo signal is not output from PD PWB K for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB. 4202 Laser output error (cyan)
The pin photo signal is not output from PD PWB C for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4203 Laser output error (magenta)
The pin photo signal is not output from PD PWB M for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4204 Laser output error (yellow)
The pin photo signal is not output from PD PWB Y for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4600 LSU cleaning motor error
When the LSU cleaning motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB. 4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB. 5301 Broken cleaning lamp K wire
When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5302 Broken cleaning lamp C wire
When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5303 Broken cleaning lamp M wire
When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5304 Broken cleaning lamp Y wire
When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 6000 Broken fuser heater wire
The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s in warming up. The fuser temperature does not reach 100„aC/212„aF after the fuser heater has been turned on continuously for 30 s in warming up. The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s during printing. Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6020 Abnormally high fuser thermistor temperature
The fuser thermistor detects a temperature higher than 240C/464F. By the activation of the high temperature error detection circuit (230C/446F or more) of fuser thermistor, the illumination of fuser heater was forcibly turned off and 10 s has elapsed. Shorted fuser thermistor. Defective engine PWB. 6030 Broken fuser thermistor wire
Input from fuser thermistor is 3 or less (A/D value) continuously for 1 s. Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6400 Zero-cross signal error
The zero-cross signal does not reach the engine PWB for more than 1 s. Defective connector cable or poor contact in the connector. Defective power source PWB or engine PWB 7001 Toner motor K error
When the toner motor K is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7002 Toner motor C error
When the toner motor C is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7003 Toner motor M error
When the toner motor M is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7004 Toner motor Y error
When the toner motor Y is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7401 Developing unit K noninstalling error
No density detection signal is output from toner sensor K in developing unit K. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7402 Developing unit C noninstalling error
No density detection signal is output from toner sensor C in developing unit C. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7403 Developing unit M noninstalling error
No density detection signal is output from toner sensor M in developing unit M. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7404 Developing unit Y noninstalling error
No density detection signal is output from toner sensor Y in developing unit Y. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7411 Drum unit K non- installing error
The EEPROM of drum PWB K does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7412 Drum unit C non- installing error
The EEPROM of drum PWB C does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7413 Drum unit M non- installing error
The EEPROM of drum PWB M does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7414 Drum unit Y non- installing error
The EEPROM of drum PWB Y does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 9500
…
9520 Contact the Service Administrative Division. 9530 Backup data error
The serial number of the machine written on the EEPROM of the engine PWB differs with that is written on both the flash memory of the engine PWB and the EEPROM of the drum PWB as a backup. Replacing both the engine PWB and the drum unit at the same time. F000 Main PWB — operation panel PWB communication error Defective main PWB. Defective operation panel PWB. F010 Main PWB checksum error Defective main PWB F020 Main PWB RAM checksum errors Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM). F040 Main PWB — print engine communication error Defective main PWB. Defective engine PWB. F041 Main PWB — scanner engine communication error Defective main PWB. Defective engine PWB. F050 Print engine ROM checksum error Defective engine PWB. F051 Scanner engine ROM checksum error Defective engine PWB. F278 Power supply in drive system error Main power switch was turned off without using the power key, or a power failure has occurred.
Answer #1: Posted by freginold on September 21st, 2015 8:22 AM
This answer was accepted by the poster of the original question.
freginold
Member since:
December 20th, 2011
Points:
23,240,715
1,100
points
Hello, sounds can be very hard to troubleshoot on a copier without being able to physically hear them. However, here are some tips that may help:
— If the sounds only occur when copying/printing, try cleaning the rollers in the area where the sound is coming from. If you’re not sure how to clean them, just use a damp cloth or lint-free rag. If you have compressed air, also clean the bearings and bushings on the feed shafts.
— If it sounds like a clicking noise, then it could be a bad bearing in the fusing unit.
— If it sounds like a very rapid clicking, it could be a chipped gear.
— If it is a high-pitched squeal or squeak, it could be dirty rollers or a dirty bushing.
Fax System (W) Operation Guide Rev-2.2013.1 — Page 209
… Setting
Click [FAX TX Setting] to set the original size and other transmission conditions.
1 Display the screen. 1 From the start button, click [Control Panel], [Hardware and Sound], and [Devices and Printers]. 2 Right-click the product name of the machine you are using and select [Printing preferences] from the pull-down list.
Item
Description
Original Size…
Kyocera Net Viewer Operation Guide Rev 5.3 2013.06 — Page 47
… list. Network Groups List
The device display name and IP address appearing in the title at the top of the Network Groups dialog box represent the selected device. The columns in ascending or… contains up to 20 groups, plus the Other group which is selected by the application. Device
Network Groups
You can be resized horizontally and vertically, minimized, maximized, or restored. For …
PRESCRIBE Commands Technical Reference Manual — Rev. 4.9 — Page 219
…the lower left UR: upper right
Device-Control Instructions
KC-GL uses device-control instructions to return buffer …appear in DeviceControl Instructions on the parallel interface. If device-control instructions are received via the RS-232C interface.
Output Extended Status (ESC.O)
This instruction returns printing system status information regarding:
• On-line status • Cover…
Printing System (11),(12),(13),(14) Color Printing Guide (Fiery E100) — Page 8
… E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP,…Topics for which additional information is available by starting Help in bold, for example, output profile, that appear throughout this document. A caution concerning operations that may lead to death or injury to persons if not…
Printing System (11),(12),(13),(14) Configuration and Setup Guide (Fiery E100) — Page 8
Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP, Windows Vista, Windows 7, Windows Server 2003/2008/2008 R2 Topics for which …
Printing System (11),(12),(13),(14) Utilities Guide (Fiery E100) — Page 6
…
This document uses the following terminology and conventions. Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this document refers you to Help for additional information and explains how to access Help for which…
Printing System (11),(12),(13),(14) Printing Guide (Fiery E100) — Page 8
…
This document uses the following terminology and conventions.
Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP, Windows Vista, Windows 7, Windows Server 2003/2008/2008 R2 Topics for which…
Setup Tool Operation Guide Rev-1 — Page 42
…-1024MFP and FS-1124MFP are not supported.
• In the edit dialogs of Device Accounting Settings and Account List, default values are automatically set when a file is not set …the copy counter setting of the address book cover page is grayed out and the contents cannot be changed.
• Data can be…-3050, KM-4050, KM-5050, and TASKalfa 300i.
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 50
…in the other section of this machine, the label is safe to the laser unit is cut off when the right cover is invisible. The label shown …Devices and Radiological Health (CDRH) of laser products in 1968. Safety of laser beam
This machine has been certified by the manufacturer to the laser beam, which is opened.
1-6 This indicates that the product is on the right.
3051ci
3551ci…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 52
…’s exclusive remedy shall be replacement of any other rights, which are not genuine KYOCERA brand parts or …(d) have no obligation to furnish labor. This warranty covers Maintenance Kits and the components of Maintenance Kits included …Information > Notice
Warranty (the United States and Canada)
3051ci / 3551ci / 4551ci / 5551ci MULTIFUNCTIONAL PRODUCT LIMITED WARRANTY
KYOCERA Document Solutions…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 60
…resources. Sleep
The device automatically enters Sleep when 30 minutes (for 3051ci), 45 minutes (for 3551ci), or 60 minutes (for 4551ci or 5551ci) have passed since the device was last used … be used . It is recommended that automatically activates energy-saving mode when the machine is equipped with the device within a set to further saving of no activity that recycled as well as …
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 68
… (Option)
Network Network
TWAIN Scanning WIA Scanning
TWAIN and WIA are using the machine with a network cable (1000BASE-T, 100BASE-TX or 10BASE-T)
Administrator’s PC
Command … for communication between software applications and image acquisition devices. Optional Network (page 8-47)
2-6 Installing and Setting up the Machine > Determining the Connection Method and Preparing Cables
…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 170
…
1 Click [Start] button on the Windows, and then click [Devices and Printers]. 2 Right-click the printer driver icon of the machine, and click the [Printer properties] menu of
the printer driver. … the taskbar at the bottom right of the screen and then click the item you want to [Black] and click [OK]. The following :
NOTE When canceling printing from this machine, refer to Canceling Jobs on…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 344
Model Name 3051ci 3551ci 4551ci 5551ci
Login User Name 3000 3500 4500 5500
Login …
User Name
Result Completed
Completed
Completed
1/1
Error
Completed
Detail
Printing Jobs
Sending Jobs
Storing Jobs
Device/ Communicate
Paper/ Supplies
Close
NOTE
If the user authentication screen appears, enter your login user name and login password and press [Login]. Press the [Status/Job…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 349
… such as waiting or printing are displayed. • Press [Format] to this machine or check their status.
1 Display the screen.
1 Press the [Status/Job Cancel] key.
2 Press [Device/Communicate].
Line Off
Device/ Communicate
i-FAX
Paper/ Supplies
Check New FAX Close
The screen to this machine are displayed.
«Removable Memory (USB Memory)» • The usage and capacity…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 391
… to [On]. NOTE
If the user authentication screen appears, enter your login user name and login password and press [Login]. Set the subject automatically entered when sending device log histories by E-mail. The factory default login user name and login password are sent.
Model Name 3051ci 3551ci 4551ci 5551ci
Login User Name 3000 3500…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 407
…machine enter a sleep state immediately after printing to check the machine memory.
* Displayed only when the optional FAX Kit is selected, it to return it may appear on the machine…machine maintenance. Adjust copy density. Adjustment can be made in 7 levels.
Adjustment can be made in 7 levels. It takes 331 seconds on 3051ci, 282 seconds on 3551ci… the operating sound is done….
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 571
… 8-39 Reserve Next 5-23 Reserved copy 5-23 Resolution 6-69, 11-25, 11-26 Responding to Messages 10-24 Restart Entire Device 8-52 Restart Network 8-46 Right Cover 1 Lever 2-3 Right Cover 2 2-3 Right Cover 2 Lever 2-3 Right Cover 3 Lever 2-3 Right Job Separator 11-6
S
Safety Conventions 1-2 Safety Conventions in This Guide 1-2 Saturation 6-31 Scan Resolution
Default 8-17 Security Level 8-49 Send…
TASKalfa 3051ci/3551ci/4551ci/5551ci Printer Driver User Guide — Page 2
…TASKalfa 3551ci TASKalfa 4551ci TASKalfa 5551ci
© 2013 KYOCERA Document Solutions Inc. and/or other countries. Adobe®, Acrobat®, Adobe Reader®, Photoshop® and PostScript® are registered trademark of Apple Inc. KPDL is a trademark of Hewlett-Packard Company. User Interface screen…guide is a trademark in the United States and other countries, licensed …
TASKalfa 3051ci/3551ci/4551ci/5551ci Printer Driver User Guide — Page 46
… the feature under Available controls, and click the right arrow to move the feature to Selected controls. Windows 7 and Windows Server 2008 R2: click Start, and then click Devices and Printers.
To use that profile to print the same type of driver features to appear in the Quick Print tab.
1 Depending on the…
Если с аппаратом Kyocera TASKalfa 1800, Kyocera TASKalfa 2200 произошла проблема, откроется следующий экран с уведомлением.
• Индикатор [Внимание] на панели управления горит или мигает.
• На дисплее сообщений панели управления аппарата появилось сообщение об ошибке.
Если индикатор [Внимание] горит или мигает и на дисплее сообщений панели управления аппарата появилось сообщение об ошибке, проверьте KYOCERA Client Tool или Монитор состояния.
ПРИМЕЧАНИЕ Если индикаторы постоянно горят и мигают не так, как описано выше, вероятно, произошла ошибка службы. Выключите питание, отсоедините шнур питания и вставьте его обратно, после чего включите питание. Это может помочь сбросить ошибку. Если ошибка не исчезает, свяжитесь со своим представителем сервисной службы (тел. в Минске +375 17 291-28-24)
Ниже описаны неполадки, которые не могут быть устранены пользователем
Дисплей сообщений |
Описание |
Меры устранения |
Бункер отраб тонера перепол. или не уст. |
Бункер для отработанного тонера установлен неправильно |
Установите Бункер для отработанного тонера должным образом |
Бункер для отработанного тонера заполнен |
Замените бункер отработанного тонера |
|
Встряхните картр. с тонером |
Тонер слежался |
Откройте переднюю крышку аппарата и вытяните контейнер с тонером. Сильно встряхните контейнер с тонером и установите его на место |
Вызовите сервисный персонал. |
В аппарате произошла ошибка |
Обратите внимание на код ошибки, отображаемый в дисплее сообщений, и свяжитесь с представителем сервисной службы (тел. в Минске +375 17 291-28-24) |
Выньте бумагу с внутреннего лотка |
Извлеките бумагу из внутреннего лотка. Нажмите клавишу [OK], чтобы возобновить печать |
|
Добавьте тонер |
Закончился тонер |
Замените контейнер с тонером TK-4105 |
Загрузите бумагу в кассету # |
↑↓ (отображается попеременно) |
Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.] |
Загрузите бумагу в универсальный лоток |
↑↓ (отображается попеременно) |
Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.] |
Закройте автоподатчик оригиналов |
Открыт автоподатчик оригиналов |
Откройте и закройте автоподатчик оригиналов |
Закройте крышку автопод. оригиналов |
Открыта верхняя крышка автоподатчика оригиналов |
Откройте и закройте крышку автоподатчика оригинало |
Закройте переднюю крышку |
Открыта передняя крышка |
Откройте и закройте переднюю крышку |
Закройте правую крышку # |
Открыта какая-либо крышка |
Откройте и закройте крышку, обозначенную на экране |
Замятие бумаги. (DP) |
В автоподатчике произошло замятие бумаги. |
См. Устранение замятия бумаги в Руководстве по эксплуатации и извлеките замятую бумагу |
Замените МК |
Необходимо производить замену деталей комплекта техобслуживания MK-4105 (ремкомплекта) каждые 150 000 страниц печати. |
Данная операция должна производиться специалистом. Обратитесь к представителю сервисной службы (тел. в Минске +375 17 291-28-24) |
Замятие |
Произошло замятие бумаги в кассете или универсальном лотке |
См. Устранение замятия бумаги и извлеките замятую бумагу |
Извлеките оригиналы из автоподатчика |
Для продолжения работы необходимо извлечь оригиналы из автоподатчика оригиналов |
Извлеките оригиналы из автоподатчика оригиналов |
Кабель USB был отключен |
Кабель USB не подключен |
Нажмите клавишу [OK] и подключите кабель USB |
ПК выключен |
Нажмите клавишу [OK] и включите ПК |
|
Не удается найти KYOCERA Client Tool |
Нажмите клавишу [OK] и откройте KYOCERA Client Tool на ПК |
|
Макс. к-во сканируемых страниц |
Превышен предел сканирования |
Дальнейшее сканирование невозможно. Задание отменено. Нажмите клавишу [OK] |
Мало тонера. (Зам., когда законч.) |
Скоро понадобится заменить контейнер с тонером |
Получите новый контейнер с тонером TK-4105. |
Не оригинальный тонер |
Установлен контейнер с тонером не марки Kyocera |
Производитель не несет ответственности за повреждения, вызванные использованием неоригинального тонера. Мы рекомендуем использовать исключительно оригинальные контейнеры с тонером TK-4105. . |
Неверный ид. уч. зап. Задание отменено |
Указан неверный идентификатор учетной записи при внешней обработке задания. Задание отменено |
Нажмите клавишу [OK] |
Невозможна двусторонняя печать на этой бумаге |
Не возможна печать на бумаге выбранного формата или типа |
Нажмите клавишу [OK] и перейдите к следующему шагу: |
Недостаточно памяти. Невозможно начать выполнение задания |
Невозможно начать выполнение задания |
Повторите попытку позже |
Ограничено алгоритмом учета заданий(Печать) |
Задание отменено, поскольку его выполнение ограничено функцией учета заданий |
Нажмите клавишу [OK] |
Ограничено алгоритмом учета заданий(Сканер) |
Задание отменено, поскольку его выполнение ограничено функцией учета заданий |
Нажмите клавишу [OK] |
Очистите сканер |
Произошло загрязнение сканера |
Очистите щелевое стекло с помощью чистящей салфетки, поставляемой вместе с автоподатчиком оригиналов. |
Ошибка. Выключить |
— |
Отключите и снова включите аппарат с помощью выключателя питания |
Память переполнена |
Невозможно продолжить выполнение задания из-за отсутствия свободной памяти |
Измените разрешение печати с Быстр1200 до 600 dpi. См. Printer Driver User Guide |
Память сканера переполнена |
Дальнейшее сканирование невозможно из-за нехватки памяти сканера. |
Для отмены задания нажмите [OK] |
Перезагрузка печати. Задание отменено |
Предупреждение. Недостаточно памяти принтера. Задание отменено |
Нажмите клавишу [OK] |
Превышено ограничение учета заданий |
Превышено число распечаток из-за ограничения алгоритмом учета заданий. Достигнут предел печати |
Это задание отменено. Нажмите клавишу [OK] |
Уст.другую кассету |
Выбрано «Сдвиг» |
Для использования сдвига необходимо загрузить в другой лоток бумагу такого же формата, что и в выбранном устройстве подачи, но в другой ориентации |
Установите все оригиналы обратно и нажмите клавишу [Старт]. |
Возникает при печати двусторонних документов в режиме ручной двусторонней печати |
Извлеките оригиналы из автоподатчика оригиналов, расположите их в первоначальном порядке и положите обратно. Нажмите клавишу [OK], чтобы возобновить печать. Для отмены задания нажмите [Стоп] |
Установлен неизвестный тонер. ПК |
Региональная спецификация контейнера с тонером не соответствует спецификации аппарата |
Установите оригинальный контейнер с тонером Замените контейнер с тонером TK-4105 |
Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.
В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.
Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.
Код ошибки Описание ошибки Причина ошибки 0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. 0070 FAX control PWB incompatible detection Error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. FAX control PWB (The FAX PWB installed will not be the one designed for the machine. 0100 Backup memory device error EEPROM (Control PWB) 0120 MAC address data error
For data in which the MAC address is invalid. EEPROM (Control PWB) 0130 Backup memory read/write error (main NAMD) Flash memory (Control PWB) 0140 Backup memory data error (main NAND) Flash memory (Control PWB) 0150 Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM. 0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Defective PWB. 0180 Machine number mismatch
Machine number of control does not match. Data damage of EEPROM. 0600 Expanded memory (DIMM) installing error
The expansion memory modules (DIMM) are not correctly mounted. Improper installation expanded memory (DIMM). 0610 Expanded memory (DIMM) error
The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly. Defective expanded memory (DIMM). Defective main PWB. 0640 Hard disk error
The hard disk cannot be accessed. Defective hard disk. Defective main PWB. 0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB. Defective FAX software. Defective FAX control PWB. 0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Defective main PWB. 0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Defective FAX control PWB or main PWB. 0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. 0930 EEPROM bus error Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB. 1010 Lift motor error
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB. 1020 PF lift motor error (paper feeder 1)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1030 PF lift motor error (paper feeder 2)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1500 PF heater 1 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1510 PF heater 2 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1520 PF heater 1 high temperature error (paper feeder 2)
A temperature higher than 75aC/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1530 PF heater 2 high temperature error (paper feeder 2)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1600 PF heater 1 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1610 PF heater 2 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1620 PF heater 1 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1630 PF heater 2 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1800 Paper feeder communication error
Communication error between engine PWB and optional paper feeder. Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB. 2100 Developing motor error
The developing motor ready input is not given for 5 s during the main motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB. 2200 Drum motor error
The drum motor ready input is not given for 5 s during the drum motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB. 2330 Fuser pressure release motor error
When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2340 Fuser pressure release motor time-out error
When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2500 Paper feed motor error
The drum motor ready input is not given for 5 s during the paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB. 2600 PF paper feed motor error (paper feeder 1)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB 2610 PF paper feed motor error (paper feeder 2)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB. 2730 Developing release motor error
When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2740 Developing release motor time-out error
When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2820 Fuser motor error
The fuser motor ready input is not given for 5 s during the fuser motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB. 3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB. 3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3300 AGC error
After AGC, correct input is not obtained at CCD. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3500 Communication error between scanner and ASIC
An error code is detected. Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB. 4001 Polygon motor KM error
The polygon motor KM ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor KM. Defective engine PWB. 4002 Polygon motor CY error
The polygon motor CY ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor CY. Defective engine PWB. 4201 Laser output error (black)
The pin photo signal is not output from PD PWB K for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB. 4202 Laser output error (cyan)
The pin photo signal is not output from PD PWB C for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4203 Laser output error (magenta)
The pin photo signal is not output from PD PWB M for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4204 Laser output error (yellow)
The pin photo signal is not output from PD PWB Y for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4600 LSU cleaning motor error
When the LSU cleaning motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB. 4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB. 5301 Broken cleaning lamp K wire
When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5302 Broken cleaning lamp C wire
When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5303 Broken cleaning lamp M wire
When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5304 Broken cleaning lamp Y wire
When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 6000 Broken fuser heater wire
The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s in warming up. The fuser temperature does not reach 100„aC/212„aF after the fuser heater has been turned on continuously for 30 s in warming up. The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s during printing. Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6020 Abnormally high fuser thermistor temperature
The fuser thermistor detects a temperature higher than 240C/464F. By the activation of the high temperature error detection circuit (230C/446F or more) of fuser thermistor, the illumination of fuser heater was forcibly turned off and 10 s has elapsed. Shorted fuser thermistor. Defective engine PWB. 6030 Broken fuser thermistor wire
Input from fuser thermistor is 3 or less (A/D value) continuously for 1 s. Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6400 Zero-cross signal error
The zero-cross signal does not reach the engine PWB for more than 1 s. Defective connector cable or poor contact in the connector. Defective power source PWB or engine PWB 7001 Toner motor K error
When the toner motor K is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7002 Toner motor C error
When the toner motor C is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7003 Toner motor M error
When the toner motor M is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7004 Toner motor Y error
When the toner motor Y is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7401 Developing unit K noninstalling error
No density detection signal is output from toner sensor K in developing unit K. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7402 Developing unit C noninstalling error
No density detection signal is output from toner sensor C in developing unit C. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7403 Developing unit M noninstalling error
No density detection signal is output from toner sensor M in developing unit M. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7404 Developing unit Y noninstalling error
No density detection signal is output from toner sensor Y in developing unit Y. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7411 Drum unit K non- installing error
The EEPROM of drum PWB K does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7412 Drum unit C non- installing error
The EEPROM of drum PWB C does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7413 Drum unit M non- installing error
The EEPROM of drum PWB M does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7414 Drum unit Y non- installing error
The EEPROM of drum PWB Y does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 9500
…
9520 Contact the Service Administrative Division. 9530 Backup data error
The serial number of the machine written on the EEPROM of the engine PWB differs with that is written on both the flash memory of the engine PWB and the EEPROM of the drum PWB as a backup. Replacing both the engine PWB and the drum unit at the same time. F000 Main PWB — operation panel PWB communication error Defective main PWB. Defective operation panel PWB. F010 Main PWB checksum error Defective main PWB F020 Main PWB RAM checksum errors Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM). F040 Main PWB — print engine communication error Defective main PWB. Defective engine PWB. F041 Main PWB — scanner engine communication error Defective main PWB. Defective engine PWB. F050 Print engine ROM checksum error Defective engine PWB. F051 Scanner engine ROM checksum error Defective engine PWB. F278 Power supply in drive system error Main power switch was turned off without using the power key, or a power failure has occurred.
Tired of getting c2730 status on your Kyocera Taskalfa 3551ci, 4551ci, and 5551ci copiers? Don’t worry, if you need to fix this error we will tell you the solution for it. Here, we are sharing the method to troubleshoot the error code c2730 on Kyocera TASKalfa 3551ci, 4551ci, and 5551ci Copier. This article will also tell you the causes behind this error code. So, let’s start fixing the error.
Meaning of the error code C2730 on Kyocera Taskalfa 4551ci
The error code c2730 stands for secondary transfer release motor error. That is, the transfer release sensor does not turn on/ off when the transfer release motor is driven. If the error appears when there is noise from the machine, it may be due to a broken gear inside the secondary transfer unit. The secondary transfer release motor is located in the secondary transfer unit which is on the side door.
Causes behind the error C2730 on Kyocera Taskalfa
Following are the reasons behind this problem,
- Dirty or damaged Secondary Transfer Release Motor Assembly.
- If the gear inside the secondary transfer unit is broken.
- Damaged connector cable
- Poor contact in the connector
- The faulty drive transmission system of motor
- If the transfer release motor is defective
- Damaged engine PWB.
Solution for the error C2730 on Kyocera Taskalfa
To solve the error C2730, follow the instructions given below,
1. Solution
Check the Secondary Transfer Release Motor Assembly: The secondary transfer unit is located on the right side door. First, remove the side cover from the Machine, there you can see the secondary transfer roller. Then, remove the secondary transfer unit from the side cover. The motor, gear, and sensor are situated inside the secondary transfer unit. So, check whether the motor, gear, and sensor are broken or not. So, replace them if broken.
2. Solution
Check the Connectors and Connector cables. Also, make sure that the connectors are properly installed.
3. Solution
If the error still persist, then check the engine PWB.
-
10-24-2014
#1
Technician
- Rep Power
- 26
TaskAlfa 3050ci error C2730
hi
the error code C2730 is the transfer release motor inside the transfer belt. i replace the transfer belt but the error is still there. please need assistant asap. thanks in advance.
Regards
Dynsam
-
10-24-2014
#2
Technician
- Rep Power
- 19
Re: TaskAlfa 3050ci error C2730
C2730- Secondary transfer release motor error
Try the Press release motor check (U030) and see what the result is and check the colour release sensor is still in place.
Also check the paper conveying unit to make sure that the sensors are clean.
-
10-24-2014
#3
Technician
- Rep Power
- 26
Re: TaskAlfa 3050ci error C2730
Originally Posted by MCC-support
C2730- Secondary transfer release motor error
Try the Press release motor check (U030) and see what the result is and check the colour release sensor is still in place.
Also check the paper conveying unit to make sure that the sensors are clean.thanks MCC-support.
i changed a new transfer belt and also the paper conveying unit but still.
-
10-24-2014
#4
Senior Tech
100+ Posts
- Rep Power
- 30
Re: TaskAlfa 3050ci error C2730
Originally Posted by dynsam
thanks MCC-support.
i changed a new transfer belt and also the paper conveying unit but still.
the solution is to change the motor behind the transfer «roller».
the error tells you what to do.=> change the ranfer roller release motor.if you want to go the easy way, change the complete conveying unit.
this takes 5 minutes.have fun
-
01-18-2023
#5
Junior Member
- Rep Power
- 0
Re: TaskAlfa 3050ci error C2730
-
3 Weeks Ago
#6
Senior Tech
100+ Posts
- Rep Power
- 30
Re: TaskAlfa 3050ci error C2730
Originally Posted by Mahmoud Esawy
I Went on a machine yesterday with this code. Do I need the motor and the housing or just the housing. (it is making a clicking noise)
-
3 Weeks Ago
#7
Re: TaskAlfa 3050ci error C2730
in 90% of cases, I only change the housing. In some cases I also had to replace the motor and gears.
-
3 Weeks Ago
#8
Senior Tech
100+ Posts
- Rep Power
- 30
Re: TaskAlfa 3050ci error C2730
Thanks for the input. The customer is close, so I may just go pull it out and look at it. I hate making a return trip and not having all the correct parts
Answer #1: Posted by freginold on September 21st, 2015 8:22 AM
This answer was accepted by the poster of the original question.
freginold
Member since:
December 20th, 2011
Points:
23,240,715
1,100
points
Hello, sounds can be very hard to troubleshoot on a copier without being able to physically hear them. However, here are some tips that may help:
— If the sounds only occur when copying/printing, try cleaning the rollers in the area where the sound is coming from. If you’re not sure how to clean them, just use a damp cloth or lint-free rag. If you have compressed air, also clean the bearings and bushings on the feed shafts.
— If it sounds like a clicking noise, then it could be a bad bearing in the fusing unit.
— If it sounds like a very rapid clicking, it could be a chipped gear.
— If it is a high-pitched squeal or squeak, it could be dirty rollers or a dirty bushing.
Fax System (W) Operation Guide Rev-2.2013.1 — Page 209
… Setting
Click [FAX TX Setting] to set the original size and other transmission conditions.
1 Display the screen. 1 From the start button, click [Control Panel], [Hardware and Sound], and [Devices and Printers]. 2 Right-click the product name of the machine you are using and select [Printing preferences] from the pull-down list.
Item
Description
Original Size…
Kyocera Net Viewer Operation Guide Rev 5.3 2013.06 — Page 47
… list. Network Groups List
The device display name and IP address appearing in the title at the top of the Network Groups dialog box represent the selected device. The columns in ascending or… contains up to 20 groups, plus the Other group which is selected by the application. Device
Network Groups
You can be resized horizontally and vertically, minimized, maximized, or restored. For …
PRESCRIBE Commands Technical Reference Manual — Rev. 4.9 — Page 219
…the lower left UR: upper right
Device-Control Instructions
KC-GL uses device-control instructions to return buffer …appear in DeviceControl Instructions on the parallel interface. If device-control instructions are received via the RS-232C interface.
Output Extended Status (ESC.O)
This instruction returns printing system status information regarding:
• On-line status • Cover…
Printing System (11),(12),(13),(14) Color Printing Guide (Fiery E100) — Page 8
… E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP,…Topics for which additional information is available by starting Help in bold, for example, output profile, that appear throughout this document. A caution concerning operations that may lead to death or injury to persons if not…
Printing System (11),(12),(13),(14) Configuration and Setup Guide (Fiery E100) — Page 8
Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP, Windows Vista, Windows 7, Windows Server 2003/2008/2008 R2 Topics for which …
Printing System (11),(12),(13),(14) Utilities Guide (Fiery E100) — Page 6
…
This document uses the following terminology and conventions. Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this document refers you to Help for additional information and explains how to access Help for which…
Printing System (11),(12),(13),(14) Printing Guide (Fiery E100) — Page 8
…
This document uses the following terminology and conventions.
Term or convention Aero Copier E100 Titles in italics Windows
Refers to
E100 (in illustrations and examples) TASKalfa XX50ci Fiery E100 Color Server Other documents in this set Microsoft Windows XP, Windows Vista, Windows 7, Windows Server 2003/2008/2008 R2 Topics for which…
Setup Tool Operation Guide Rev-1 — Page 42
…-1024MFP and FS-1124MFP are not supported.
• In the edit dialogs of Device Accounting Settings and Account List, default values are automatically set when a file is not set …the copy counter setting of the address book cover page is grayed out and the contents cannot be changed.
• Data can be…-3050, KM-4050, KM-5050, and TASKalfa 300i.
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 50
…in the other section of this machine, the label is safe to the laser unit is cut off when the right cover is invisible. The label shown …Devices and Radiological Health (CDRH) of laser products in 1968. Safety of laser beam
This machine has been certified by the manufacturer to the laser beam, which is opened.
1-6 This indicates that the product is on the right.
3051ci
3551ci…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 52
…’s exclusive remedy shall be replacement of any other rights, which are not genuine KYOCERA brand parts or …(d) have no obligation to furnish labor. This warranty covers Maintenance Kits and the components of Maintenance Kits included …Information > Notice
Warranty (the United States and Canada)
3051ci / 3551ci / 4551ci / 5551ci MULTIFUNCTIONAL PRODUCT LIMITED WARRANTY
KYOCERA Document Solutions…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 60
…resources. Sleep
The device automatically enters Sleep when 30 minutes (for 3051ci), 45 minutes (for 3551ci), or 60 minutes (for 4551ci or 5551ci) have passed since the device was last used … be used . It is recommended that automatically activates energy-saving mode when the machine is equipped with the device within a set to further saving of no activity that recycled as well as …
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 68
… (Option)
Network Network
TWAIN Scanning WIA Scanning
TWAIN and WIA are using the machine with a network cable (1000BASE-T, 100BASE-TX or 10BASE-T)
Administrator’s PC
Command … for communication between software applications and image acquisition devices. Optional Network (page 8-47)
2-6 Installing and Setting up the Machine > Determining the Connection Method and Preparing Cables
…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 170
…
1 Click [Start] button on the Windows, and then click [Devices and Printers]. 2 Right-click the printer driver icon of the machine, and click the [Printer properties] menu of
the printer driver. … the taskbar at the bottom right of the screen and then click the item you want to [Black] and click [OK]. The following :
NOTE When canceling printing from this machine, refer to Canceling Jobs on…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 344
Model Name 3051ci 3551ci 4551ci 5551ci
Login User Name 3000 3500 4500 5500
Login …
User Name
Result Completed
Completed
Completed
1/1
Error
Completed
Detail
Printing Jobs
Sending Jobs
Storing Jobs
Device/ Communicate
Paper/ Supplies
Close
NOTE
If the user authentication screen appears, enter your login user name and login password and press [Login]. Press the [Status/Job…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 349
… such as waiting or printing are displayed. • Press [Format] to this machine or check their status.
1 Display the screen.
1 Press the [Status/Job Cancel] key.
2 Press [Device/Communicate].
Line Off
Device/ Communicate
i-FAX
Paper/ Supplies
Check New FAX Close
The screen to this machine are displayed.
«Removable Memory (USB Memory)» • The usage and capacity…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 391
… to [On]. NOTE
If the user authentication screen appears, enter your login user name and login password and press [Login]. Set the subject automatically entered when sending device log histories by E-mail. The factory default login user name and login password are sent.
Model Name 3051ci 3551ci 4551ci 5551ci
Login User Name 3000 3500…
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 407
…machine enter a sleep state immediately after printing to check the machine memory.
* Displayed only when the optional FAX Kit is selected, it to return it may appear on the machine…machine maintenance. Adjust copy density. Adjustment can be made in 7 levels.
Adjustment can be made in 7 levels. It takes 331 seconds on 3051ci, 282 seconds on 3551ci… the operating sound is done….
TASKalfa 3051ci/3551ci/4551ci/5551ci Operation Guide Rev-1 2013.6 — Page 571
… 8-39 Reserve Next 5-23 Reserved copy 5-23 Resolution 6-69, 11-25, 11-26 Responding to Messages 10-24 Restart Entire Device 8-52 Restart Network 8-46 Right Cover 1 Lever 2-3 Right Cover 2 2-3 Right Cover 2 Lever 2-3 Right Cover 3 Lever 2-3 Right Job Separator 11-6
S
Safety Conventions 1-2 Safety Conventions in This Guide 1-2 Saturation 6-31 Scan Resolution
Default 8-17 Security Level 8-49 Send…
TASKalfa 3051ci/3551ci/4551ci/5551ci Printer Driver User Guide — Page 2
…TASKalfa 3551ci TASKalfa 4551ci TASKalfa 5551ci
© 2013 KYOCERA Document Solutions Inc. and/or other countries. Adobe®, Acrobat®, Adobe Reader®, Photoshop® and PostScript® are registered trademark of Apple Inc. KPDL is a trademark of Hewlett-Packard Company. User Interface screen…guide is a trademark in the United States and other countries, licensed …
TASKalfa 3051ci/3551ci/4551ci/5551ci Printer Driver User Guide — Page 46
… the feature under Available controls, and click the right arrow to move the feature to Selected controls. Windows 7 and Windows Server 2008 R2: click Start, and then click Devices and Printers.
To use that profile to print the same type of driver features to appear in the Quick Print tab.
1 Depending on the…
Если с аппаратом Kyocera TASKalfa 1800, Kyocera TASKalfa 2200 произошла проблема, откроется следующий экран с уведомлением.
• Индикатор [Внимание] на панели управления горит или мигает.
• На дисплее сообщений панели управления аппарата появилось сообщение об ошибке.
Если индикатор [Внимание] горит или мигает и на дисплее сообщений панели управления аппарата появилось сообщение об ошибке, проверьте KYOCERA Client Tool или Монитор состояния.
ПРИМЕЧАНИЕ Если индикаторы постоянно горят и мигают не так, как описано выше, вероятно, произошла ошибка службы. Выключите питание, отсоедините шнур питания и вставьте его обратно, после чего включите питание. Это может помочь сбросить ошибку. Если ошибка не исчезает, свяжитесь со своим представителем сервисной службы (тел. в Минске +375 17 291-28-24)
Ниже описаны неполадки, которые не могут быть устранены пользователем
Дисплей сообщений |
Описание |
Меры устранения |
Бункер отраб тонера перепол. или не уст. |
Бункер для отработанного тонера установлен неправильно |
Установите Бункер для отработанного тонера должным образом |
Бункер для отработанного тонера заполнен |
Замените бункер отработанного тонера |
|
Встряхните картр. с тонером |
Тонер слежался |
Откройте переднюю крышку аппарата и вытяните контейнер с тонером. Сильно встряхните контейнер с тонером и установите его на место |
Вызовите сервисный персонал. |
В аппарате произошла ошибка |
Обратите внимание на код ошибки, отображаемый в дисплее сообщений, и свяжитесь с представителем сервисной службы (тел. в Минске +375 17 291-28-24) |
Выньте бумагу с внутреннего лотка |
Извлеките бумагу из внутреннего лотка. Нажмите клавишу [OK], чтобы возобновить печать |
|
Добавьте тонер |
Закончился тонер |
Замените контейнер с тонером TK-4105 |
Загрузите бумагу в кассету # |
↑↓ (отображается попеременно) |
Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.] |
Загрузите бумагу в универсальный лоток |
↑↓ (отображается попеременно) |
Загрузите бумагу. Нажмите клавишу [OK] и перейдите к следующему шагу. • Для выбора другого устройства подачи выберите [Выберите бумагу]. • Для печати на бумаге, в настоящее время находящейся в устройстве подачи, выберите [Продолж. без изм.] |
Закройте автоподатчик оригиналов |
Открыт автоподатчик оригиналов |
Откройте и закройте автоподатчик оригиналов |
Закройте крышку автопод. оригиналов |
Открыта верхняя крышка автоподатчика оригиналов |
Откройте и закройте крышку автоподатчика оригинало |
Закройте переднюю крышку |
Открыта передняя крышка |
Откройте и закройте переднюю крышку |
Закройте правую крышку # |
Открыта какая-либо крышка |
Откройте и закройте крышку, обозначенную на экране |
Замятие бумаги. (DP) |
В автоподатчике произошло замятие бумаги. |
См. Устранение замятия бумаги в Руководстве по эксплуатации и извлеките замятую бумагу |
Замените МК |
Необходимо производить замену деталей комплекта техобслуживания MK-4105 (ремкомплекта) каждые 150 000 страниц печати. |
Данная операция должна производиться специалистом. Обратитесь к представителю сервисной службы (тел. в Минске +375 17 291-28-24) |
Замятие |
Произошло замятие бумаги в кассете или универсальном лотке |
См. Устранение замятия бумаги и извлеките замятую бумагу |
Извлеките оригиналы из автоподатчика |
Для продолжения работы необходимо извлечь оригиналы из автоподатчика оригиналов |
Извлеките оригиналы из автоподатчика оригиналов |
Кабель USB был отключен |
Кабель USB не подключен |
Нажмите клавишу [OK] и подключите кабель USB |
ПК выключен |
Нажмите клавишу [OK] и включите ПК |
|
Не удается найти KYOCERA Client Tool |
Нажмите клавишу [OK] и откройте KYOCERA Client Tool на ПК |
|
Макс. к-во сканируемых страниц |
Превышен предел сканирования |
Дальнейшее сканирование невозможно. Задание отменено. Нажмите клавишу [OK] |
Мало тонера. (Зам., когда законч.) |
Скоро понадобится заменить контейнер с тонером |
Получите новый контейнер с тонером TK-4105. |
Не оригинальный тонер |
Установлен контейнер с тонером не марки Kyocera |
Производитель не несет ответственности за повреждения, вызванные использованием неоригинального тонера. Мы рекомендуем использовать исключительно оригинальные контейнеры с тонером TK-4105. . |
Неверный ид. уч. зап. Задание отменено |
Указан неверный идентификатор учетной записи при внешней обработке задания. Задание отменено |
Нажмите клавишу [OK] |
Невозможна двусторонняя печать на этой бумаге |
Не возможна печать на бумаге выбранного формата или типа |
Нажмите клавишу [OK] и перейдите к следующему шагу: |
Недостаточно памяти. Невозможно начать выполнение задания |
Невозможно начать выполнение задания |
Повторите попытку позже |
Ограничено алгоритмом учета заданий(Печать) |
Задание отменено, поскольку его выполнение ограничено функцией учета заданий |
Нажмите клавишу [OK] |
Ограничено алгоритмом учета заданий(Сканер) |
Задание отменено, поскольку его выполнение ограничено функцией учета заданий |
Нажмите клавишу [OK] |
Очистите сканер |
Произошло загрязнение сканера |
Очистите щелевое стекло с помощью чистящей салфетки, поставляемой вместе с автоподатчиком оригиналов. |
Ошибка. Выключить |
— |
Отключите и снова включите аппарат с помощью выключателя питания |
Память переполнена |
Невозможно продолжить выполнение задания из-за отсутствия свободной памяти |
Измените разрешение печати с Быстр1200 до 600 dpi. См. Printer Driver User Guide |
Память сканера переполнена |
Дальнейшее сканирование невозможно из-за нехватки памяти сканера. |
Для отмены задания нажмите [OK] |
Перезагрузка печати. Задание отменено |
Предупреждение. Недостаточно памяти принтера. Задание отменено |
Нажмите клавишу [OK] |
Превышено ограничение учета заданий |
Превышено число распечаток из-за ограничения алгоритмом учета заданий. Достигнут предел печати |
Это задание отменено. Нажмите клавишу [OK] |
Уст.другую кассету |
Выбрано «Сдвиг» |
Для использования сдвига необходимо загрузить в другой лоток бумагу такого же формата, что и в выбранном устройстве подачи, но в другой ориентации |
Установите все оригиналы обратно и нажмите клавишу [Старт]. |
Возникает при печати двусторонних документов в режиме ручной двусторонней печати |
Извлеките оригиналы из автоподатчика оригиналов, расположите их в первоначальном порядке и положите обратно. Нажмите клавишу [OK], чтобы возобновить печать. Для отмены задания нажмите [Стоп] |
Установлен неизвестный тонер. ПК |
Региональная спецификация контейнера с тонером не соответствует спецификации аппарата |
Установите оригинальный контейнер с тонером Замените контейнер с тонером TK-4105 |
Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.
В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.
Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.
Код ошибки Описание ошибки Причина ошибки 0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. 0070 FAX control PWB incompatible detection Error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. FAX control PWB (The FAX PWB installed will not be the one designed for the machine. 0100 Backup memory device error EEPROM (Control PWB) 0120 MAC address data error
For data in which the MAC address is invalid. EEPROM (Control PWB) 0130 Backup memory read/write error (main NAMD) Flash memory (Control PWB) 0140 Backup memory data error (main NAND) Flash memory (Control PWB) 0150 Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM. Defective engine PWB. Device damage of EEPROM. 0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM. Defective PWB. 0180 Machine number mismatch
Machine number of control does not match. Data damage of EEPROM. 0600 Expanded memory (DIMM) installing error
The expansion memory modules (DIMM) are not correctly mounted. Improper installation expanded memory (DIMM). 0610 Expanded memory (DIMM) error
The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly. Defective expanded memory (DIMM). Defective main PWB. 0640 Hard disk error
The hard disk cannot be accessed. Defective hard disk. Defective main PWB. 0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB. Defective FAX software. Defective FAX control PWB. 0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB. Defective main PWB. 0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Defective FAX control PWB or main PWB. 0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. 0930 EEPROM bus error Defective drum PWB (EEPROM). Defective engine PWB (EEPROM). Defective engine PWB. Defective main PWB. 1010 Lift motor error
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB. 1020 PF lift motor error (paper feeder 1)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1030 PF lift motor error (paper feeder 2)
When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively. Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB. 1500 PF heater 1 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1510 PF heater 2 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1520 PF heater 1 high temperature error (paper feeder 2)
A temperature higher than 75aC/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB. 1530 PF heater 2 high temperature error (paper feeder 2)
A temperature higher than 75C/167F is detected. Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB. 1600 PF heater 1 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1610 PF heater 2 low temperature error (paper feeder 1)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1620 PF heater 1 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB. 1630 PF heater 2 low temperature error (paper feeder 2)
An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 2 is turned on. Defective connector cable or poor contact in the connector. PF thermistor 2 installed incorrectly. Defective PF thermistor 2. Broken PF heater 2. Defective PF heater PWB or PF main PWB. 1800 Paper feeder communication error
Communication error between engine PWB and optional paper feeder. Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB. 2100 Developing motor error
The developing motor ready input is not given for 5 s during the main motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing motor. Defective developing motor. Defective engine PWB. 2200 Drum motor error
The drum motor ready input is not given for 5 s during the drum motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB. 2330 Fuser pressure release motor error
When the fuser pressure release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2340 Fuser pressure release motor time-out error
When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB. 2500 Paper feed motor error
The drum motor ready input is not given for 5 s during the paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB. 2600 PF paper feed motor error (paper feeder 1)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB 2610 PF paper feed motor error (paper feeder 2)
The drum motor ready input is not given for 2 s during the PF paper feed motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB. 2730 Developing release motor error
When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2740 Developing release motor time-out error
When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s. Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB. 2820 Fuser motor error
The fuser motor ready input is not given for 5 s during the fuser motor is ON. Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB. 3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB. 3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3300 AGC error
After AGC, correct input is not obtained at CCD. Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB. 3500 Communication error between scanner and ASIC
An error code is detected. Defective connector cable or poor contact in the connector. Defective CCD PWB. Defective main PWB. 4001 Polygon motor KM error
The polygon motor KM ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor KM. Defective engine PWB. 4002 Polygon motor CY error
The polygon motor CY ready input is not given for 10 s during the polygon motor is ON. Defective connector cable or poor contact in the connector. Defective polygon motor CY. Defective engine PWB. 4201 Laser output error (black)
The pin photo signal is not output from PD PWB K for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB. 4202 Laser output error (cyan)
The pin photo signal is not output from PD PWB C for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4203 Laser output error (magenta)
The pin photo signal is not output from PD PWB M for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4204 Laser output error (yellow)
The pin photo signal is not output from PD PWB Y for one second while laser is emitted. Defective connector cable or poor contact in the connector. Defective APC PWB C. Defective PD PWB C. Defective engine PWB. 4600 LSU cleaning motor error
When the LSU cleaning motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB. 4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector. Defective main PWB or engine PWB. 5301 Broken cleaning lamp K wire
When the cleaning lamp K is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5302 Broken cleaning lamp C wire
When the cleaning lamp C is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5303 Broken cleaning lamp M wire
When the cleaning lamp M is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 5304 Broken cleaning lamp Y wire
When the cleaning lamp Y is driven, the lamp over-current detection signal is detected continuously for 10 times (1 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective cleaning lamp K. Defective engine PWB. 6000 Broken fuser heater wire
The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s in warming up. The fuser temperature does not reach 100„aC/212„aF after the fuser heater has been turned on continuously for 30 s in warming up. The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The detected temperature of fuser thermistor does not rise 1„aC/1.8„aF after the fuser heater has been turned on continuously for 10 s during printing. Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6020 Abnormally high fuser thermistor temperature
The fuser thermistor detects a temperature higher than 240C/464F. By the activation of the high temperature error detection circuit (230C/446F or more) of fuser thermistor, the illumination of fuser heater was forcibly turned off and 10 s has elapsed. Shorted fuser thermistor. Defective engine PWB. 6030 Broken fuser thermistor wire
Input from fuser thermistor is 3 or less (A/D value) continuously for 1 s. Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Broken fuser heater wire. Defective engine PWB. 6400 Zero-cross signal error
The zero-cross signal does not reach the engine PWB for more than 1 s. Defective connector cable or poor contact in the connector. Defective power source PWB or engine PWB 7001 Toner motor K error
When the toner motor K is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7002 Toner motor C error
When the toner motor C is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7003 Toner motor M error
When the toner motor M is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7004 Toner motor Y error
When the toner motor Y is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. Defective connector cable or poor contact in the connector. Defective drive transmission system of the toner motor K. Defective toner motor K. Defective engine PWB. 7401 Developing unit K noninstalling error
No density detection signal is output from toner sensor K in developing unit K. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7402 Developing unit C noninstalling error
No density detection signal is output from toner sensor C in developing unit C. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7403 Developing unit M noninstalling error
No density detection signal is output from toner sensor M in developing unit M. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7404 Developing unit Y noninstalling error
No density detection signal is output from toner sensor Y in developing unit Y. Defective connector cable or poor contact in the connector. Defective toner sensor K. Defective engine PWB. 7411 Drum unit K non- installing error
The EEPROM of drum PWB K does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7412 Drum unit C non- installing error
The EEPROM of drum PWB C does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7413 Drum unit M non- installing error
The EEPROM of drum PWB M does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 7414 Drum unit Y non- installing error
The EEPROM of drum PWB Y does not communicate normally. Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB. 9500
…
9520 Contact the Service Administrative Division. 9530 Backup data error
The serial number of the machine written on the EEPROM of the engine PWB differs with that is written on both the flash memory of the engine PWB and the EEPROM of the drum PWB as a backup. Replacing both the engine PWB and the drum unit at the same time. F000 Main PWB — operation panel PWB communication error Defective main PWB. Defective operation panel PWB. F010 Main PWB checksum error Defective main PWB F020 Main PWB RAM checksum errors Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM). F040 Main PWB — print engine communication error Defective main PWB. Defective engine PWB. F041 Main PWB — scanner engine communication error Defective main PWB. Defective engine PWB. F050 Print engine ROM checksum error Defective engine PWB. F051 Scanner engine ROM checksum error Defective engine PWB. F278 Power supply in drive system error Main power switch was turned off without using the power key, or a power failure has occurred.