Kyocera ошибка 7914

2JZ/2JX/2JV/2H7-1

Code

C7912

Developing unit C EEPROM error

No response is issued from the device in

reading/writing for 5 ms or more and this

problem is repeated five times succes-

sively.

Mismatch of reading data from two loca-

tions occurs eight times successively.

Mismatch between writing data and

reading data occurs eight times succes-

sively.

C7913

Developing unit M EEPROM error

No response is issued from the device in

reading/writing for 5 ms or more and this

problem is repeated five times succes-

sively.

Mismatch of reading data from two loca-

tions occurs eight times successively.

Mismatch between writing data and

reading data occurs eight times succes-

sively.

C7914

Developing unit Y EEPROM error

No response is issued from the device in

reading/writing for 5 ms or more and this

problem is repeated five times succes-

sively.

Mismatch of reading data from two loca-

tions occurs eight times successively.

Mismatch between writing data and

reading data occurs eight times succes-

sively.

C7950

High voltage control PWB error

A communication error from high voltage

control PWB is detected 10 times in suc-

cession.

C8020

Punch motor problem (optional 3000-

sheet document finisher)

The error signal of the punch motor is

detected for more than 500 ms while the

punch motor is operating.

1-4-50

Contents

Causes

Check procedures/corrective measures

Poor contact in the

Check the connection of connector YC6 on

connector termi-

the sub front PWB and the continuity across

nals.

the connector terminals. Repair or replace if

necessary.

Defective develop-

Replace the developing unit C (see page 1-

ing PWB C.

5-34).

Poor contact in the

Check the connection of connector YC8 on

connector termi-

the sub front PWB and the continuity across

nals.

the connector terminals. Repair or replace if

necessary.

Defective develop-

Replace the developing unit M (see page 1-

ing PWB M.

5-34).

Poor contact in the

Check the connection of connector YC4 on

connector termi-

the sub front PWB and the continuity across

nals.

the connector terminals. Repair or replace if

necessary.

Defective develop-

Replace the developing unit Y (see page 1-

ing PWB Y.

5-34).

Poor contact in the

Check the connection of connector YC30 on

connector termi-

the engine PWB and the connector on the

nals.

high voltage control PWB, and the continuity

across the connector terminals. Repair or

replace if necessary.

Defective PWB.

Replace the high voltage control PWB or

engine PWB and check for correct opera-

tion.

Poor contact in the

Check the connection of connector on the

connector termi-

punch PWB and the continuity across the

nals.

connector terminals. Repair or replace if

necessary.

Defective punch

Replace the punch motor.

motor.

Defective PWB.

Replace the punch PWB or finisher main

PWB and check for correct operation.

Remarks

Ошибки Kyocera ECOSYS M2030dn

Ошибки Kyocera ECOSYS M2030pn

Ошибки Kyocera ECOSYS M2035dn

Ошибки Kyocera ECOSYS M2040dn

Ошибки Kyocera ECOSYS M2135dn

Ошибки Kyocera ECOSYS M2530dn

Ошибки Kyocera ECOSYS M2535dn

Ошибки Kyocera ECOSYS M2540dn

Ошибки Kyocera ECOSYS M2540dw

Ошибки Kyocera ECOSYS M2635dn

Ошибки Kyocera ECOSYS M2635dw

Ошибки Kyocera ECOSYS M2640idw

Ошибки Kyocera ECOSYS M3040dn

Ошибки Kyocera ECOSYS M3040idn

Ошибки Kyocera ECOSYS M3145dn

Ошибки Kyocera ECOSYS M3145idn

Ошибки Kyocera ECOSYS M2735dw

Ошибки Kyocera ECOSYS M3540dn

Ошибки Kyocera ECOSYS M3540idn

Ошибки Kyocera ECOSYS M3550idn

Ошибки Kyocera ECOSYS M3560idn

Ошибки Kyocera ECOSYS M3645dn

Ошибки Kyocera ECOSYS M3645idn

Ошибки Kyocera ECOSYS M3655idn

Ошибки Kyocera ECOSYS M3660idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M4125idn

Ошибки Kyocera ECOSYS M4132idn

Ошибки Kyocera ECOSYS M5521cdn

Ошибки Kyocera ECOSYS M5521cdw

Ошибки Kyocera ECOSYS M5526cdn

Ошибки Kyocera ECOSYS M5526cdw

Ошибки Kyocera ECOSYS M6026cdn

Ошибки Kyocera ECOSYS M6026cidn

Ошибки Kyocera ECOSYS M6030cdn

Ошибки Kyocera ECOSYS M6035cidn

Ошибки Kyocera ECOSYS M6230cidn

Ошибки Kyocera ECOSYS M6235cidn

Ошибки Kyocera ECOSYS M6526cdn

Ошибки Kyocera ECOSYS M6526cidn

Ошибки Kyocera ECOSYS M6530cdn

Ошибки Kyocera ECOSYS M6535cidn

Ошибки Kyocera ECOSYS M6630cidn

Ошибки Kyocera ECOSYS M6635cidn

Ошибки Kyocera ECOSYS M8124cidn

Ошибки Kyocera ECOSYS M8130cidn

Ошибки Kyocera ECOSYS P2035d

Ошибки Kyocera ECOSYS P2040dn

Ошибки Kyocera ECOSYS P2040dw

Ошибки Kyocera ECOSYS P2135d

Ошибки Kyocera ECOSYS P2135dn

Ошибки Kyocera ECOSYS P2235dn

Ошибки Kyocera ECOSYS P2235dw

Ошибки Kyocera ECOSYS P3045dn

Ошибки Kyocera ECOSYS P3050dn

Ошибки Kyocera ECOSYS P3055dn

Ошибки Kyocera ECOSYS P3060dn

Ошибки Kyocera ECOSYS P3145dn

Ошибки Kyocera ECOSYS P3150dn

Ошибки Kyocera ECOSYS P3155dn

Ошибки Kyocera ECOSYS P3160dn

Ошибки Kyocera ECOSYS P3260dn

Ошибки Kyocera ECOSYS P4035dn

Ошибки Kyocera ECOSYS P4040dn

Ошибки Kyocera ECOSYS P5021cdn

Ошибки Kyocera ECOSYS P5021cdw

Ошибки Kyocera ECOSYS P5026cdn

Ошибки Kyocera ECOSYS P5026cdw

Ошибки Kyocera ECOSYS P6021cdn

Ошибки Kyocera ECOSYS P6026cdn

Ошибки Kyocera ECOSYS P6030cdn

Ошибки Kyocera ECOSYS P6035cdn

Ошибки Kyocera ECOSYS P6130cdn

Ошибки Kyocera ECOSYS P6230cdn

Ошибки Kyocera ECOSYS P6235cdn

Ошибки Kyocera ECOSYS P7035cdn

Ошибки Kyocera ECOSYS P7040cdn

Ошибки Kyocera ECOSYS P7240cdn

Ошибки Kyocera ECOSYS P8060cdn

Ошибки Kyocera FS-C8600DN

Ошибки Kyocera FS-C8650DN

Ошибки Kyocera FS1016MFP

Ошибки Kyocera FS1018MFP

Ошибки Kyocera FS1020MFP

Ошибки Kyocera FS1024MFP

Ошибки Kyocera FS1025MFP

Ошибки Kyocera FS1028MFP

Ошибки Kyocera FS1030MFP

Ошибки Kyocera FS1035MFP

Ошибки Kyocera FS1040

Ошибки Kyocera FS1050

Ошибки Kyocera FS1060DN

Ошибки Kyocera FS1100

Ошибки Kyocera FS1110

Ошибки Kyocera FS1116MFP

Ошибки Kyocera FS1118MFP

Ошибки Kyocera FS1120

Ошибки Kyocera FS1120MFP

Ошибки Kyocera FS1124MFP

Ошибки Kyocera FS1125MFP

Ошибки Kyocera FS1128MFP

Ошибки Kyocera FS1130MFP

Ошибки Kyocera FS1135MFP

Ошибки Kyocera FS1200

Ошибки Kyocera FS1220MFP

Ошибки Kyocera FS1300D

Ошибки Kyocera FS1320D

Ошибки Kyocera FS1320MFP

Ошибки Kyocera FS1325MFP

Ошибки Kyocera FS1350DN

Ошибки Kyocera FS1370DN

Ошибки Kyocera FS1500

Ошибки Kyocera FS6020

Ошибки Kyocera FS6025MFP

Ошибки Kyocera FS6025MFPB

Ошибки Kyocera FS6030MFP

Ошибки Kyocera FS6500

Ошибки Kyocera FS6525MFP

Ошибки Kyocera FS6530MFP

Ошибки Kyocera FS6700

Ошибки Kyocera FS6900

Ошибки Kyocera FS6950DN

Ошибки Kyocera FS8000CD

Ошибки Kyocera FS8000CN

Ошибки Kyocera FS8100DN

Ошибки Kyocera TASKalfa 180

Ошибки Kyocera TASKalfa 1800

Ошибки Kyocera TASKalfa 1801

Ошибки Kyocera TASKalfa 181

Ошибки Kyocera TASKalfa 205c

Ошибки Kyocera TASKalfa 220

Ошибки Kyocera TASKalfa 2200

Ошибки Kyocera TASKalfa 2201

Ошибки Kyocera TASKalfa 221

Ошибки Kyocera TASKalfa 2420w

Ошибки Kyocera TASKalfa 2460ci

Ошибки Kyocera TASKalfa 2470ci

Ошибки Kyocera TASKalfa 250ci

Ошибки Kyocera TASKalfa 2510i

Ошибки Kyocera TASKalfa 2520i

Ошибки Kyocera TASKalfa 255

Ошибки Kyocera TASKalfa 2550ci

Ошибки Kyocera TASKalfa 2551ci

Ошибки Kyocera TASKalfa 2552ci

Ошибки Kyocera TASKalfa 2553ci

Ошибки Kyocera TASKalfa 255b

Ошибки Kyocera TASKalfa 255c

Ошибки Kyocera TASKalfa 265ci

Ошибки Kyocera TASKalfa 300ci

Ошибки Kyocera TASKalfa 300i

Ошибки Kyocera TASKalfa 3010i

Ошибки Kyocera TASKalfa 3011i

Ошибки Kyocera TASKalfa 305

Ошибки Kyocera TASKalfa 3050ci

Ошибки Kyocera TASKalfa 3051ci

Ошибки Kyocera TASKalfa 306ci

Ошибки Kyocera TASKalfa 307ci

Ошибки Kyocera TASKalfa 308ci

Ошибки Kyocera TASKalfa 3212i

Ошибки Kyocera TASKalfa 3252ci

Ошибки Kyocera TASKalfa 3253ci

Ошибки Kyocera TASKalfa 3500i

Ошибки Kyocera TASKalfa 3501i

Ошибки Kyocera TASKalfa 350ci

Ошибки Kyocera TASKalfa 3510i

Ошибки Kyocera TASKalfa 3511i

Ошибки Kyocera TASKalfa 3550ci

Ошибки Kyocera TASKalfa 3551ci

Ошибки Kyocera TASKalfa 3552ci

Ошибки Kyocera TASKalfa 3553ci

Ошибки Kyocera TASKalfa 356ci

Ошибки Kyocera TASKalfa 358ci

Ошибки Kyocera TASKalfa 4002i

Ошибки Kyocera TASKalfa 4003i

Ошибки Kyocera TASKalfa 400ci

Ошибки Kyocera TASKalfa 4012i

Ошибки Kyocera TASKalfa 4052ci

Ошибки Kyocera TASKalfa 4053ci

Ошибки Kyocera TASKalfa 406ci

Ошибки Kyocera TASKalfa 408ci

Ошибки Kyocera TASKalfa 420i

Ошибки Kyocera TASKalfa 4500i

Ошибки Kyocera TASKalfa 4501i

Ошибки Kyocera TASKalfa 4550ci

Ошибки Kyocera TASKalfa 4551ci

Ошибки Kyocera TASKalfa 4820w

Ошибки Kyocera TASKalfa 5002i

Ошибки Kyocera TASKalfa 5003i

Ошибки Kyocera TASKalfa 500ci

Ошибки Kyocera TASKalfa 5052ci

Ошибки Kyocera TASKalfa 5053ci

Ошибки Kyocera TASKalfa 508ci

Ошибки Kyocera TASKalfa 520i

Ошибки Kyocera TASKalfa 5500i

Ошибки Kyocera TASKalfa 5501i

Ошибки Kyocera TASKalfa 550c

Ошибки Kyocera TASKalfa 552ci

Ошибки Kyocera TASKalfa 5550ci

Ошибки Kyocera TASKalfa 5551ci

Ошибки Kyocera TASKalfa 6002i

Ошибки Kyocera TASKalfa 6003i

Ошибки Kyocera TASKalfa 6052ci

Ошибки Kyocera TASKalfa 6053ci

Ошибки Kyocera TASKalfa 620

Ошибки Kyocera TASKalfa 6500i

Ошибки Kyocera TASKalfa 6501i

Ошибки Kyocera TASKalfa 650c

Ошибки Kyocera TASKalfa 6550ci

Ошибки Kyocera TASKalfa 6551ci

Ошибки Kyocera TASKalfa 7002i

Ошибки Kyocera TASKalfa 7003i

Ошибки Kyocera TASKalfa 7052ci

Ошибки Kyocera TASKalfa 7353ci

Ошибки Kyocera TASKalfa 750c

Ошибки Kyocera TASKalfa 7550ci

Ошибки Kyocera TASKalfa 7551ci

Ошибки Kyocera TASKalfa 8000i

Ошибки Kyocera TASKalfa 8001i

Ошибки Kyocera TASKalfa 8002i

Ошибки Kyocera TASKalfa 8003i

Ошибки Kyocera TASKalfa 8052ci

Ошибки Kyocera TASKalfa 820

Ошибки Kyocera TASKalfa 8353ci

Ошибки Kyocera TASKalfa 9002i

Ошибки Kyocera TASKalfa 9003i

Содержание

  • 1 Самые распространенные коды ошибок принтеров Kyocera
  • 2 Код C7990
  • 3 Способ №2. Замена чипа
  • 4 Другие неисправности
  • 5 Способ №1. Сброс счетчика страниц / тонера
  • 6 Сброс ошибок у принтеров Kyocera своими руками
  • 7 Способы решения проблемы
    • 7.1 Сброс сообщения о неоригинальном тонере на Kyocera fs 1040
  • 8  
  • 9  
  • 10  
  • 11  
  • 12  
  • 13  
  • 14 Значения мигания индикаторов

Слово «ошибка» на английском языке будет «ошибка», поэтому большинство кодов начинаются с заглавной E.

Итак, какие ошибки могут возникать в принтерах Kyocera FS 1020MFP японского производства:

1.E-0002. Указывает, что картридж с тонером не подходит для региональных спецификаций. Вам нужно использовать другой картридж.
2.E-0003. Эта ошибка указывает на то, что память сканера заполнена. Будут доступны только самые последние отсканированные изображения. Чтобы сбросить ошибку E-0003, необходимо очистить память сканера. Для этого нажмите Стоп / Сброс.

Стирание памяти

Стирание памяти

3.E-0007. Значит, для печати не хватает чернил. Исправить код 07 просто — нужно добавить тонер.
4. При открытой задней или передней крышке МФУ Kyocera не работает и выдает код ошибки E-0008.
5. После печати или копирования большого количества бумаги (сто листов), если лоток не опорожняется, отображается сообщение об ошибке принтера Kyocera E-0009. Вам нужно удалить листы и нажать кнопку Старт, чтобы продолжить работу.
6. Иногда выдается код E-0012, что означает, что задача не может быть выполнена из-за нехватки оперативной памяти. Для решения этой проблемы необходимо изменить разрешение печати с 1200 на 600. Порядок действий описан в инструкции.
7. Когда появится код E-0014, загрузите бумагу нужного формата во входной лоток. Размер листов определяется драйвером принтера.
8. Если вы забыли подключить сетевой или USB-кабель, принтер отобразит код ошибки E-0015. Нужно нажать Stop / Reset, подключить кабель и снова нажать эту кнопку.

Замена картриджа с тонером

Замена картриджа с тонером

В японских принтерах Kyocera FS 1020MFP могут возникать ошибки, как описанные в предыдущем разделе, так и конкретные ошибки. Все коды можно найти в инструкции по эксплуатации.

Код C7990

Этот номер ошибки на моделях FS 1020MFP указывает на сигнал о переполнении тонера.

Ошибка C7990

Ошибка C7990

Причин возникновения ошибки C7990 может быть три:

• неисправна плата PWB;
• неисправен датчик количества краски;
• бункер действительно полон — рекомендуется заменить барабан.

Барабан

Барабан

В первых двух случаях необходимо обратиться в сервисный центр.

В третьем случае появления кода C7990, если ресурс барабана еще не исчерпан, можно очистить бункер для краски. Делают они это так:

1. Откройте переднюю крышку и выньте блок проявки.
2. Подойдите к барабану.
3. Осторожно откройте крышку бункера и удалите краску.
4. Соберите прибор в обратном порядке.

Как видите, ошибку принтера Kyocera C7990 легко устранить самостоятельно, а обращаться к специалистам нужно только тогда, когда карты действительно плохие.

Основные ошибки принтеров Kyocera

Способ №2. Замена чипа

Альтернативный вариант сброса счетчика вручную — замена микросхемы. Вы можете заправлять картридж принтера KyoceraFS-1040 сколько угодно, но благодаря установке нового защитного чипа устройство не распознает замену расходного материала.

Ошибочно многие пользователи считают неисправностью, когда на корпусе принтера Kuoser 1040 горит красная кнопка с сообщением «Внимание» и принтер не печатает присланные ему документы. В этом материале мы рассмотрим, в каких случаях это происходит, что делать, как быстро все отремонтировать в домашних условиях, не обращаясь в сервисный центр. Инструкции применимы ко многим моделям Kyocera. Например, fs1040 взят из-за его популярности.

Другие неисправности

Также возможно появление таких кодов:

• C-F040. Вам нужно выключить и снова включить устройство, нажав кнопку питания.
• J-0511. Код указывает на то, что бумага застряла под задней крышкой. Инструкции описывают, как удалить бумагу в соответствующем разделе.
• ПФ. Принтер предложит вам добавить бумагу во входной лоток.

Основные ошибки принтеров Kyocera

Как видите, принтеры японской компании Kyocera выходят из строя редко. Чаще всего ошибки возникают из-за неправильных или неосторожных действий. Вы можете исправить их самостоятельно, но если не уверены в своих силах, лучше проконсультироваться со специалистом.

Способ №1. Сброс счетчика страниц / тонера

Чтобы запустить принтер KyoceraFS-1040, просто сбросьте счетчик страниц / тонера, удерживая нажатыми кнопки «Отмена» и «GO».

Единственная проблема заключается в том, что удаление предупреждения принтера об использовании неоригинального картриджа может привести к аннулированию гарантии. Так как устройство записывает абсолютно все ошибки в «Журнал событий».

Сброс ошибок у принтеров Kyocera своими руками

Сбрасывая ошибки в принтерах Kyocera, необходимо понимать ряд мер, которые опытный пользователь может потенциально предпринять для восстановления и запуска печатающих устройств без обращения в сервисный центр.

Ошибка №

Это вызывает

Решение

E-0001

В принтер установлен совместимый картридж или повреждена микросхема расходных материалов. Проблему можно решить несколькими способами:

1 установите оригинальный картридж;

2 замена поврежденного чипа;

3 прошивки принтера — так что любой картридж можно устанавливать в принтер неограниченное количество раз;

4 сброс ошибки — держать нажатыми несколько секунд кнопки «Режим» и «Сброс».

E-0002

Регион используемого картриджа не соответствует техническим характеристикам принтера. Проблему можно решить несколькими способами:

1. Установите картридж, соответствующий региону принтера;

3 прошивки принтера.

E-0003

Память печатающего устройства заполнена. Распечатайте уже отсканированные документы или сбросьте операцию с помощью соответствующей кнопки.

E-0007

В картридже закончился тонер. Замените картридж на новый, оригинальный, совместимый или заправьте расходный материал.

E-0008

Одна из крышек принтера не закрыта. Закройте переднюю и заднюю крышки принтера до щелчка.

E-0009

Лоток для печати заполнен. Удалите отпечатанную бумагу и возобновите печать, нажав кнопку «Пуск».

E-0012

Память принтера заполнена. Измените разрешение печати до 600 dpi.

E-0014

Установлен формат бумаги, не поддерживаемый принтером. Замените бумагу листами совместимого размера.

Иногда функциональность принтера может быть ограничена на программном уровне.

Для расширения диапазона форматов рекомендуется обновить программное обеспечение печатающего устройства.

E-0015

1. В принтере нет питания.

2. Сетевой кабель не подключен.

3. На ПК нет драйверов. Проверьте целостность сетевого кабеля.

При необходимости установите драйвер.

E-0018

Выбранный файл отсутствует в очереди печати. Сбросьте операцию, нажав кнопку «Сброс». Затем выберите новый файл и продолжите печать.

E-0019

Формат печати не поддерживается принтером. Сбросьте операцию, нажав кнопку «Сброс».

J-0511

Бумага замята. Осторожно удалите оставшуюся бумагу из корпуса принтера.

ПФ

Во входном лотке нет бумаги. Загрузите бумагу во входной лоток и возобновите печать, нажав кнопку «Пуск».

Способы решения проблемы

Сброс сообщения о неоригинальном тонере на Kyocera fs 1040

Если вышеперечисленные варианты не сработали, то, скорее всего, проблема в самом картридже. Дело в том, что он оснащен датчиком уровня тонера и чипом, отслеживающим количество отпечатанных листов. Когда расходный материал заканчивается или, согласно чипу, он должен закончиться, печать блокируется до тех пор, пока он не будет заменен новым картриджем. Именно это и произошло в нашей ситуации.

Есть три варианта решения проблемы:

  1. Купите новый картридж и продолжайте его печатать. Это недешево.
  2. После каждой пополнения порошка следует заменять чип, который начнет отсчет количества распечатанных документов с нуля.
  3. Сбросить счетчик на микросхеме. Сделать это несложно, но делать это нужно каждый раз при включении устройства.

Инструкции по сбросу:

  • Включите устройство.
  • Подождите, пока двигатель остановится и красный свет не начнет мигать.
  • Одновременно нажмите кнопки «Пуск» и «Отмена» на 5-7 секунд».
  • Нажмите и удерживайте, пока красный и зеленый не начнут мигать по очереди.
  • Ждем завершения процесса.
  • Пытаюсь распечатать.

 

 

 

 

 

 

Значения мигания индикаторов

  • Ничего не горит и уведомлений нет, значит, устройство полностью готово к работе.
  • Медленное мигание кнопки означает, что в лотке нет бумаги или в картридже низкий уровень пыли.
  • Индикатор мигает быстрее: внутри устройства застрял лист бумаги, лоток окончательной обработки заполнен, и распечатки невозможно вставить, вся память принтера заполнена и используются неоригинальные расходные материалы.
  • Индикатор горит и не гаснет. Проверьте, закрыты ли крышки. Тонер для печати, возможно, уже закончился.

Если у вас возникли трудности с определением причин появления сообщения «Внимание», вы можете воспользоваться специальным программным обеспечением от инженеров компании — «Kyocera Client Tool». Эта утилита поможет вам более точно диагностировать проблему. Вы можете найти его на сайте компании или на диске с драйверами принтера.

Источники

  • http://printergid.ru/neispravnosti/oshibki-kyocera
  • https://dudom.ru/kompjutery/kyocera-1040-indikacija-oshibok/
  • https://window-10.ru/ecosys-fs-1020mfp-oshibka-e7/

[свернуть]

Ошибки Kyocera ECOSYS M5521cdn

  • Code: 0030
  • Description: FAX PWB system error The FAX process cannot be continued due to the malfunction of the FAX PWB.
  • Remedy: FAX PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Reinstall the FAX firmware. 3. Replace the FAX PWB.
  • Code: 0070
  • Description: FAX PWB incompatible detection error In the initial communication with the FAX PWB, any normal communication command is not transmitted.
  • Remedy: Main/engine PWB Replace the main/engine PWB.
  • Code: 0100
  • Description: Backup memory device error Outputs an abnormal status from the flash memory.
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check that the connectors on the main/engine PWB are properly connected, and if not, re-connect them. 3. Replace the main/engine PWB.
  • Code: 0120
  • Description: MAC address data error In case MAC address is invalid data
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check the MAC address on the network status page. 3. If it is blank, obtain an EEPROM with its MAC address written by the service support and install it. 4. Replace the main/engine PWB.
  • Code: 0130
  • Description: Backup memory Read/write error (Main/ Engine PWB) Read/write to the NAND memory cannot be executed.
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check that the connectors on the main/engine PWB are properly connected, and if not, re-connect them. 3. Replace the main/engine PWB.
  • Code: 0140
  • Description: Backup memory data error (Main/Engine PWB) At power up, the data that was read from the NAND memory has been determined to be a error.
  • Remedy: Flash memory (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute U021 initialize memory. 3. Replace the main/engine PWB.
  • Code: 0150
  • Description: EEPROM read/ write error (Main/Engine PWB) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: EEPROM (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check that the EEPROM is properly installed on the main/ engine PWB and if not, reinstall it. 3. Replace the main/engine PWB. 4. Check the EEPROM and if it is damaged, contact the service support.
  • Code: 0160
  • Description: EEPROM data error (Main/Engine PWB) Reading data from EEPROM is detected abnormal.
  • Remedy: EEPROM (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute U021 initialize memory. 3. If the EEPROM data is corrupted, contact the service support.
  • Code: 0170
  • Description: Billing counting error Mismatch between the value of the main/engine PWB and EEPROM, in one of the value of billing counter, life counter, or scanner counter.
  • Remedy: EEPROM (Main/Engine PWB) 1. Check that the EEPROM installed in the main/ engine PWB is correct and, if not, install the correct EEPROM for the model. 2. Replace the main/engine PWB. 3. If the EEPROM data is corrupted, contact the service support.
  • Code: 0180
  • Description: Machine number mismatch When the power is turned on, the machine number does not match the one stored in the main/engine PWB.
  • Remedy: EEPROM (Main/Engine PWB) 1. Check that the EEPROM installed in the main/ engine PWB is correct and, if not, install the correct EEPROM for the model. 2. Confirm the serial number data for the main/ engine PWB by using U004. If the mutually different machine number data between «Machine No. (Main)» and «Machine No. (Eng)» is displayed, or if there is a difference between the actual machine number and the number of «Machine No. (Eng)», install the correct EEPROM, and then execute U004.
  • Code: 0190
  • Description: Backup memory device error (engine) Unable to read out data from the IC on the main unit PWB. Read out data from the IC on the main unit PWB. (3 retrials)
  • Remedy: EEPROM (Main/Engine PWB) 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check that the connectors on the main/engine PWB are properly connected, and if not, re-connect them. 3. Contact service headquarters to get an EEPROM to install.
  • Code: 0800
  • Description: Image formation problems The printing sequence JAM (J010X) is detected for 2 consecutive times.
  • Remedy: Main/Engine PWB 1. Check if the problem is a printing operation error detection in a particular file, and if it is possible to obtain the reproduction of the phenomena by the identification of the job that detected the error, and take the job log. 2. If the problem occurs in an unspecified job, check the connectors on the main/engine PWB, and reattach it. 3. Replace the main/engine PWB.

Коды ошибок > Kyocera > ECOSYS M5521cdn > стр. 3

  • Каталог

  • Вход

  • Контакты

  • Форум

  • Rus

  • Коды ошибок
  • Kyocera
  • ECOSYS M5521cdn
  • Все коды

Коды ошибок стр. 3

  • Code: 0830
  • Description: FAX PWB flash Program area Checksum error The program stored in the flash memory on the FAX PWB is broken and cannot be executed.
  • Remedy: FAX firmware Reinstall the FAX firmware.
    FAX PWB 1. Unplug the power cord from the wall outlet, and reinstall the FAX PWB, and then plug in the power cord and turn the power on. 2. Check the connection failure between the KUIO connector of the main/engine PWB and FAX PWB, and reconnect it. 3. Execute [Initializing] by U600. 4. Replace the FAX PWB.
  • Code: 0840
  • Description: Faults of RTC [Check at powerup] The RTC setting has reverted to a previous state. Or, the machine has not been turned on for 5 years (regularly compared with a set value stored in the EEPROM). The RTC setting is older than 00:01 on January 1, 2000. [Checked periodically (at every 5 minutes) after powerup.] The RTC setting has reverted to a state older than the last time it was checked. 10 minutes have been passed since the previous check.
  • Remedy: Settings of RTC Execute Date Setting using the system menu.
    Backup battery (Main/Engine PWB) 1. Check if the backup battery on the main/engine PWB is not short-circuited. 2. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. Then plug in the power cord and then turn on the power switch. If the same service call error is displayed, replace the backup battery.
    Main/Engine PWB 1. If the communication error (due to a noise, etc.) is present with the RTC on the main/engine PWB, check that the PWB is properly grounded or secured by screws. 2. Replace the main/engine PWB.
  • Code: 0870
  • Description: FAX PWB — Main/Engine PWB image data transfer error High-capacity data transfer between the FAX PWB and the main/engine PWB was not normally performed even if the data transfer was retried the specified times.
  • Remedy: FAX PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Reinstall the FAX PWB, and then plug in the power cord and turn the power on. 2. Check the connection failure between the KUIO connector of the main/engine PWB and FAX PWB, and reconnect it. 3. Replace the F
  • Code: 2200
  • Description: Main motor steady-state error After the motor is stabilized, the ready signal is turned OFF for continuous 1 s.
  • Remedy: Drum unit BK Check that the drum can be rotated by hand, and if it is locked, replace the drum unit BK.
    Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Main motor — Main/Engine PWB (YC11)
    Main motor drive transmission system 1. Check if the couplings and gears rotate smoothly, and if not, clean or grease the gears. 2. Check for broken couplings and gears, and replace if any are found.
    Main motor Replace the main motor.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 2500
  • Description: Paper feed motor error After the motor starting, the ready signal is not turned ON for continuous 2 s. In case the Ready signal does not turn ON 1s in succession after the motor is in the steady-state.
  • Remedy: Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. Check the continuity within the connector wire. If none, replace the wire. Paper feed motor — container relay PWB (YC11)
    Drive transmission system for the paper feed motor 1. Check if the rollers and gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check for broken gears and replace if any are found.
    Paper feed motor Replace the paper feed motor.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 3100
  • Description: Carriage error When turning the power on, or when the reading of the original document by table or DP scanning has completed, the home position sensor is not turned off, even if the home position sensor is on and the scanner carriage moves to the scanning direction. ?Or, the home position sensor does not turn on, even if the home position sensor is off and the scanner carriage moves to the return direction.
  • Remedy: Scanner motor 1. Move the scanner by hand to check whether it smoothly moves. 2. Check that the scanner drive belt is not disengaged. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Scanner motor — Main/Engine PWB (YC19) 4. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 5. Replace the scanner motor.
    Home position Sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Home position sensor — Main/Engine PWB (YC17) 3. Replace the home position sensor.
    CIS Replace the image scanner carriage and execute U411.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 3200
  • Description: CIS lamp error The white standard data obtained when the lamp is turned on at the time of an initialization is lower than the rated value.
  • Remedy: CIS Replace the image scanner carriage and execute U411.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 3210
  • Description: DP CIS lamp error The white standard data obtained when the lamp is turned on at the time of an initialization is lower than the rated value. (M26 ppm model only)
  • Remedy: DP CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DP CIS — Main/Engine PWB(YC4) 2. Replace DP CIS and execute U411.
  • Code: 3300
  • Description: CIS AGC error In case a normal input could not be obtained from the CCD at AGC.
  • Remedy: CIS 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS — Main/Engine PWB(YC18) 4. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 5. Replace the image scanner carriage and execute U411.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 3310
  • Description: DP CIS AGC error In case a normal input could not be obtained from the CIS at AGC. (M36 ppm model only)
  • Remedy: DP CIS 6. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. DPCIS — Main/Engine PWB(YC4) 7. Replace DPCIS and execute U411.
  • Code: 3500
  • Description: Scanner and ASIC communication error A communication error is detected. (Read back values are different.)
  • Remedy: CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS — Main/Engine PWB(YC18) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. If the LED is not lit, replace the scanner carriage and execute U411.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 4000
  • Description: Polygon motor startup error After the polygon motor starts, the motor stable signal is not turned ON after 10 s.
  • Remedy: Polygon motor 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Polygon motor — Main/Engine PWB(YC20) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 4010
  • Description: Polygon motor steady-state error After the polygon motor stabilization, the motor stable signal is turned OFF for consecutive 1 s or more.
  • Remedy: Polygon motor 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Polygon motor — Main/Engine PWB (YC20) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 4101
  • Description: BD initialization error(K) In case the BD signal is not detected for 1s after starting the polygon motor drive.
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU — Main/Engine PWB (YC21) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the controller firmware and engine firmware, and upgrade to the latest version. 2. Replace the main/engine PWB.
  • Code: 4102
  • Description: BD initialization error(C) In case the BD signal is not detected for 1s after starting the polygon motor drive.
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU — Main/Engine PWB(YC21)If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 2. Replace the LSU.
    Main/Engine PWB 1. Check the controller firmware and engine firmware, and upgrade to the latest version. 2. Replace the main/engine PWB.
  • Code: 4103
  • Description: BD initialization error(M) In case the BD signal is not detected for 1s after starting the polygon motor drive.
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU — Main/Engine PWB (YC21) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the controller firmware and engine firmware, and upgrade to the latest version. 2. Replace the main/engine PWB.
  • Code: 4104
  • Description: BD initialization error(Y) In case the BD signal is not detected for 1s after starting the polygon motor drive.
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. LSU — Main/Engine PWB (YC21) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the controller firmware and engine firmware, and upgrade to the latest version. 2. Replace the main/engine PWB.
  • Code: 4600
  • Description: Cleaning motor error Over-current is detected for 5s during the LSU cleaning motor drive.
  • Remedy: Cleaning wire 1. Execute [LSU cleaning] using [Adjustment/Maintenance] of the system menu. 2. Check that the drive gear and cleaning spiral can rotate and they are not unusually loaded, and if necessary, clean and grease.
    Cleaning motor 1. Confirm that the cleaning motor has been firmly attached. 2. Replace the LSU.
    Main/Engine PWB 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by another component, or has defective conduction, replace it. Cleaning motor — container relay PWB (YC13) 3. Replace the main/engine PWB.
  • Code: 4700
  • Description: VIDEO_ASIC device error Communication with the video ASIC has failed 5 times successively. After writing to the VIDEO ASIC, the error that the reading value from the same address does not match occurs 8 times successively.
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check that the connectors on the main/engine PWB are properly connected, and if not, re-connect them. 3. Replace the main/engine PWB.
    High voltage PWB 1. Check if the main charger roller contact on the high voltage PWB is deformed or dirty. 2. Replace the high voltage PWB.
    Main/Engine PWB Replace the main/engine PWB.
  • Code: 6000
  • Description: Broken fuser heater wire During warm up, the temperature detected by the thermistor does not reach 100 °C/212.0 °F for 20 s. During warm up, the temperature detected by the thermistor does not reach the stable display temperature for 40 s, after it reaches 100 °C/212.0 °F.
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit — Main/Engine PWB(YC23) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit.
    Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Low voltage power supply PWB — Maine/Engine PWB(YC1) 2. Replace the main/engine PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 6020
  • Description: Fuser thermistor High temperature error The temperature detected by the thermistor (edge) exceeded 220 °C/428.0 °F for 1s in succession.
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Check if the fuser roller has foreign objects such as the toner contamination. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit — Main/Engine PWB(YC23) 4. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 5. Replace the fuser unit.
    Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Low voltage power supply PWB — Maine/Engine PWB(YC1) 2. If the fuser heater is turned on at all times, replace the low voltage power supply PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Check if the main/engine PWB is properly secured with screws. 3. Replace the main/engine PWB.
  • Code: 6030
  • Description: Fuser thermistor wire break The average AD value from ten values at every 2ms while deducting the maximum and minimum values is monitored at every 100ms and it is detected at the wire break level (1020 or more).
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit — Main/Engine PWB(YC23) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 4. Replace the fuser unit.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 6050
  • Description: Fuser thermistor Low temperature error In case the temperature detected by the thermistor (edge) continues 80 °C/ 176.0 °F or less for 1 second during ready or printing.
  • Remedy: Reduction of the power supply voltage 1. Check that no voltage drop of more than 10% of the rated is caused during printing. 2. If the power is overloaded, change the AC outlet that supplies power.
    Fuser unit 1. Make sure there is no paper jam. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser unit — Main/Engine PWB(YC23) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 4. If the fuser heater is not turned on (broken thermostat wire), replace the fuser unit.
    Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Low voltage power supply PWB — Main/Engine PWB(YC1) 2. Replace the low voltage power supply PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 6400
  • Description: Zero-cross signal error During the fuser heater on, the zero-cross signal is not input for 1 s successively.
  • Remedy: Low voltage power supply PWB 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Low voltage power supply PWB — Maine/Engine PWB(YC1) 2. Replace the main/engine PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 6610
  • Description: The fuser pressure release error The fuser release sensor does not turn on or off, after 10 s from starting pressurization or depressurization operation.
  • Remedy: Fuser unit 1. Make sure there is no paper jam. 2. Check if the fuser pressure can be reduced by inverse rotation of the fuser gear by hand. 3. Check if the envelope sensor light is blocked out by the actuator during depressurization operation. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Fuser pressure release sensor — container relay PWB (YC2) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the fuser unit.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7101
  • Description: Toner sensor error (Black) For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container 1. Check that the toner container is properly installed, and if necessary, re-install. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Toner Sensor 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Toner sensor — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner Solenoid 1. Check that the toner solenoid is properly attached. 2. Check if the couplings and gears can rotate or if they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner solenoid — container relay PWB (YC3) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Change the toner solenoid.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7102
  • Description: Toner sensor error (Cyan) For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container 1. Check that the toner container is properly installed, and if necessary, re-install. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Toner Sensor 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Toner sensor — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner Solenoid 1. Check that the toner solenoid is properly attached. 2. Check if the couplings and gears can rotate or if they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner solenoid — container relay PWB (YC3) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Change the toner solenoid.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7103
  • Description: Toner sensor error (Magenta) For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container 1. Check that the toner container is properly installed, and if necessary, re-install. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Toner Sensor 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Toner sensor — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner Solenoid 1. Check that the toner solenoid is properly attached. 2. Check if the couplings and gears can rotate or if they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner solenoid — container relay PWB (YC3) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Change the toner solenoid.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7104
  • Description: Toner sensor error (Yellow) For a certain period of time, the sensor output value is less than 0.1V, or more than 3.2V.
  • Remedy: Toner container 1. Check that the toner container is properly installed, and if necessary, re-install. 2. Check that the toner supply inlet of the toner container can be opened by the lever operation. 3. Replace the toner container.
    Toner Sensor 1. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. Toner sensor — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Check if the gears and spirals in the developer unit rotate smoothly. 4. Replace the developer unit.
    Toner Solenoid 1. Check that the toner solenoid is properly attached. 2. Check if the couplings and gears can rotate or if they are not unusually loaded, and if necessary, replace. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Toner solenoid — container relay PWB (YC3) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Change the toner solenoid.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7200
  • Description: Broken inner thermistor wire (Developer) The sensor input sampling value is greater than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Developer unit BK 1. Confirm that the connector of the developer unit BK is firmly connected, and if necessary, push the unit all the way in. Toner sensor BK — Unit relay PWB (YC9) Unit relay PWB — Main/Engine PWB(YC7) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Replace the developer unit BK.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7210
  • Description: Short-circuited inner thermistor (Developer) The sensor input sampling value is less than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Developer unit BK 1. Confirm that the connector of the developer unit BK is firmly connected, and if necessary, push the unit all the way in. Toner sensor BK — Unit relay PWB (YC9) Unit relay PWB — Main/Engine PWB(YC7) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Replace the developer unit BK.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7221
  • Description: Broken inner thermistor wire (LSU) The sensor input sampling value is greater than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector of the LSU is firmly connected, and if necessary, connect the connector all the way in. LSU — Main/Engine PWB (YC21) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7231
  • Description: Short-circuited inner thermistor (LSU) The sensor input sampling value is less than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Laser scanner unit (LSU) 1. Confirm that the wiring connector of the LSU is firmly connected, and if necessary, connect the connector all the way in. LSU — Main/Engine PWB (YC21) 2. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 3. Replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7401
  • Description: Developer unit type Mismatch error (Black) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7402
  • Description: Developer unit type Mismatch error (Cyan) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7403
  • Description: Developer unit type Mismatch error (Magenta) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7404
  • Description: Developer unit type mismatch error (Yellow) Improper adaptation of the main unit and developer unit is detected.
  • Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7411
  • Description: Drum unit type Mismatch error (Black) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7412
  • Description: Drum unit type Mismatch error (Cyan) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7413
  • Description: Drum unit type Mismatch error (Magenta) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7414
  • Description: Drum unit type Mismatch error (Yellow) Improper adaptation of the main unit and drum unit is detected.
  • Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7601
  • Description: ID sensor error (front) When the measured value of the ID sensor matches any of the following. The dark potential P/Swave is greater than 0.8V. If the light potential S-wave is lower than the dark potential S-wave. If the light potential P-wave is lower than the dark potential P-wave (+0.5V).
  • Remedy: ID sensor 1. Clean the ID sensor surface. 2. Check how the ID sensor is attached. 3. Check if the error is detected after performing the calibration. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. ID sensor — Main/Engine PWB (YC24) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the ID sensor.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7602
  • Description: ID sensor error (rear) When the measured value of the ID sensor matches any of the following. The dark potential P/Swave is greater than 0.8V. If the light potential S-wave is lower than the dark potential S-wave. If the light potential P-wave is lower than the dark potential P-wave (+0.5V).
  • Remedy: ID sensor 1. Clean the ID sensor surface. 2. Check how the ID sensor is attached. 3. Check if the error is detected after performing the calibration. 4. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. ID sensor — Main/Engine PWB (YC24) 5. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 6. Replace the ID sensor.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7611
  • Description: Bias calibration reading value error (Black) During the calibration, the ID sensor cannot read a patch density on the primary transfer belt normally.
  • Remedy: Primary transfer belt ID sensor 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute [Calibration] using [Adjustment/Maintenance] of the system menu. 3. Check the occurrence of this service call error in the Event Log. 4. When the same service call error is detected again, clean if there is any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether or not the ID sensor shutter is open, by opening and closing the paper tray. 6. If not corrected, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether there is any failure in the drum unit, developer unit, LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7612
  • Description: Bias calibration reading value error (Cyan) During the calibration, the ID sensor cannot read a patch density on the primary transfer belt normally.
  • Remedy: Primary transfer belt ID sensor 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute [Calibration] using [Adjustment/Maintenance] of the system menu. 3. Check the occurrence of this service call error in the Event Log. 4. When the same service call error is detected again, clean if there is any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether or not the ID sensor shutter is open, by opening and closing the paper tray. 6. If not corrected, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether there is any failure in the drum unit, developer unit, LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7613
  • Description: Bias calibration reading value error (Magenta) During the calibration, the ID sensor cannot read a patch density on the primary transfer belt normally.
  • Remedy: Primary transfer belt ID sensor 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute [Calibration] using [Adjustment/Maintenance] of the system menu. 3. Check the occurrence of this service call error in the Event Log. 4. When the same service call error is detected again, clean if there is any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether or not the ID sensor shutter is open, by opening and closing the paper tray. 6. If not corrected, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether there is any failure in the drum unit, developer unit, LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7614
  • Description: Bias calibration reading value error (Yellow) During the calibration, the ID sensor cannot read a patch density on the primary transfer belt normally.
  • Remedy: Primary transfer belt ID sensor 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute [Calibration] using [Adjustment/Maintenance] of the system menu. 3. Check the occurrence of this service call error in the Event Log. 4. When the same service call error is detected again, clean if there is any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether or not the ID sensor shutter is open, by opening and closing the paper tray. 6. If not corrected, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether there is any failure in the drum unit, developer unit, LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7620
  • Description: Color Registration timing of detection Color patches printed on the primary transfer belt are not within the ID sensor readable range. Or the poor density occurs.
  • Remedy: Primary transfer belt ID sensor LSU 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Execute [Calibration] using [Adjustment/Maintenance] of the system menu. 3. Check the occurrence of this service call error in the Event Log. 4. When the same service call error is detected again, clean if there is any dirt or stains on the primary transfer belt or the ID sensor surface. 5. Check whether or not the ID sensor shutter is open, by opening and closing the paper tray. 6. If not corrected, replace the primary transfer unit. 7. After performing the test print, if the poor density occurs, check whether there is any failure in the drum unit, developer unit, LSU. 8. When checking the printing position of the color, if any color shift occurs, re-install the LSU and the drum unit. 9. If not corrected, replace the LSU.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7800
  • Description: Broken outer thermistor wire The temperature and humidity sensor input sampling value is abnormal compared with the reference. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Temperature and humidity Sensor 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Temperature and humidity sensor — Main/Engine PWB (YC35) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the Temperature and humidity sensor PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7810
  • Description: Short-circuited outer thermistor The sensor input sampling value is less than the reference value. (After detection, controlled at 25 °C/77.0 °F)
  • Remedy: Temperature and humidity Sensor 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Temperature and humidity sensor — Main/Engine PWB (YC35) 2. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. 3. Replace the Temperature and humidity sensor PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7901
  • Description: Drum unit EEPROM error (Black) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7902
  • Description: Drum unit EEPROM error (Cyan) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7903
  • Description: Drum unit EEPROM error (Magenta) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7904
  • Description: Drum unit EEPROM error (Yellow) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Drum unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the drum unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the drum unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7911
  • Description: Developer unit EEPROM error (Black) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7912
  • Description: Developer unit EEPROM error (Cyan) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7913
  • Description: Developer unit EEPROM error (Magenta) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 7914
  • Description: Developer unit EEPROM error (Yellow) No response is issued from the device in reading/ writing for 5 ms or more and this problem is repeated 5 times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Remedy: Developer unit 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the connector of the developer unit is firmly connected, and if necessary, push the unit all the way in. 3. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit — Unit relay PWB Unit relay PWB — Main/Engine PWB(YC7) 4. If the wire is disconnected, short-circuited or has a ground fault, or the connector pin is deformed, replace the wire. 5. Replace the developer unit.
    Unit relay PWB Replace the unit relay PWB.
    Main/Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the main/engine PWB.
  • Code: 9540
  • Description: Backup data error The internal data changes by replacing multiple parts at the same time, interfering with the machine operation and will not enter ready mode.
  • Remedy: PWBs In case two or more of the parts below were replaced at the same time, reattach them. Applicable parts: Memory, PWBs *When replacing the applicable parts, 2 or more do not replace then at the same time. *When replacing the above applicable parts, do not work the following at the same time. Replace the drum unit or the developing unit. Replace the drum unit for one color with another in the same machine.
  • Code: F000
  • Description: Communication error between Main/Engine PWB — Operation panel PWB
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Check the wiring and connectors between the main/engine PWB — the operation panel PWB. Operation panel PWB — Main/Engine PWB (YC26): M21 ppm model — Main/Engine PWB (YC56) : M26 ppm model 3. Check the connection of the DDR memory on the main/engine PWB by reinstalling it or replacing it. 4. Execute U021 initialize memory. 5. Replace the main/engine PWB.
    Operation panel PWB Replace the operation panel PWB.
  • Code: F000
  • Description: CF000 will be displayed if * notes progress is carried out for a definite period of time with a Welcome screen.The communication fault between Panel-Main boardsCommunication fault between Panel Core-Main Core Notes 2
  • Remedy: (1) Check the harness of * (between Main board <=>HDD), and the connection state of a connector between Panel<=>Main boards, and perform an operation check. (2) Check contact of a DDR memory (extracting) and perform an operation check. If exchangeable, it will exchange and will perform an operation check. (3) Initialize HDD and perform an operation check. (FULL of U024) * ( 4) U021 Controller backup initialization is carried out and an operation check is performed. (5) Exchange a Main board and perform an operation check. (6) Exchange a PanelMain board and perform an operation check. (7) It will get, if USBLOG is obtainable, and contact service headquarters. * : only HDD standard model * Note 2 : Only Dual Core CPU model
  • Code: F010
  • Description: Main/Engine PWB Checksum error
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. If not corrected, replace the main/engine PWB and check operation.
  • Code: F020
  • Description: Main/Engine PWB memory error In case an error occurs at the start-up DIMM read/ write check.
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. If not corrected, replace the main/engine PWB and check operation.
  • Code: F040
  • Description: Communication error between controller — Print engine
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Repair or replace the wire from the main/engine PWB that may be grounded. (Check for a shortcircuit between 5V and 3.3V.) 3. Check the FFC cable connector connecting to the main/engine PWB and reconnect it. Or replace the FFC. 4. Check both the main and engine firmware, and upgrade to the latest version, if necessary. 5. Replace the main/engine PWB.
  • Code: F050
  • Description: Print engine Main program error
  • Remedy: Main/Engine PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the power cord and then turn on the power switch. 2. Confirm that the EEPROM has been properly installed. 3. Check both the main and engine firmware, and upgrade to the latest version, if necessary. 4. If not corrected, replace the main/engine PWB.
  • Code: F12X
  • Description: Abnormality detecting in a Scan control section
  • Remedy: (1) Check the harness between Scan/DP<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange a Scan/DP board and perform an operation check. (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F14X
  • Description: Abnormality detecting in a FAX control part
  • Remedy: (1) Check the harness between FAX<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Perform a deed operation check for DIMM Clear by U671. * Notes(Since it disappears when received data remain, cautions are required.) (5) Exchange FAX_DIMM and perform an operation check. * Notes (6) Exchange a FAX board and perform an operation check. (7) Exchange a Main board and perform an operation check. (8) Get USBLOG and contact service headquarters. * Only HDD standard model * Note Only model which has Flash for FAX data in a Main board
  • Code: F15X
  • Description: Abnormality detecting in an authentication device control section
  • Remedy: (1) Check the harness between authentication device <=>Main boards, and the connection situation of a connector, and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) Carry out U021 Main backup initialization and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Exchange HDD and perform an operation check. * (6) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F18X
  • Description: Abnormality detecting in a Video control section
  • Remedy: (1) Check the harness between Engine<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) U021 Controller backup initialization is carried out and an operation check is performed. (3) Exchange an Engine board and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F1DX
  • Description: Abnormality detecting of the image memory Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F21X, F22X, F23X
  • Description: Abnormality detecting in an image-processing part
  • Remedy: (1) Check contact of a DDR memory and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) Carry out U021 Main backup initialization and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Exchange HDD and perform an operation check. * (6) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F24X
  • Description: Abnormality detecting in the system Management Department
  • Remedy: (1) Check contact of a DDR memory and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) Carry out U021 Main backup initialization and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Exchange HDD and perform an operation check. * (6) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F25X
  • Description: Abnormality detecting in a network management department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Get USBLOG and packet capture and contact service headquarters. * Only HDD standard model
  • Code: F26X, F27X, F28X
  • Description: Abnormality detecting in the system Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F29X, F2AX
  • Description: Abnormality detecting in the system Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F2BX, F2CX, F2DX
  • Description: Abnormality detecting in a network control part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Get USBLOG and contact service headquarters. (Depending on an analysis result, it is packet capture acquisition) * Only HDD standard model
  • Code: F2EX, F2FX, F30X
  • Description: Abnormality detecting in a network control part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Get USBLOG and contact service headquarters. (Depending on an analysis result, it is packet capture acquisition) * Only HDD standard model
  • Code: F31X, F32X
  • Description: Abnormality detecting in a network control part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Get USBLOG and contact service headquarters. (Depending on an analysis result, it is packet capture acquisition) * Only HDD standard model
  • Code: F33X
  • Description: Abnormality detecting in the Scan Management Department
  • Remedy: (1) Check the harness between Scan/DP<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange a Scan/DP board and perform an operation check. (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F34X
  • Description: Abnormality detecting in the Panel Management Department
  • Remedy: (1) Check the harness between Panel<=>Main boards, and the connection state of a connector, and perform an operation check. * Notes (2) Initialize HDD and perform an operation check. (FULL of U024) * ( 3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange a Panel board and perform an operation check. * Notes (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only HDD standard model * Note : A Dual Core CPU model and HyPAS model
  • Code: F35X
  • Description: Abnormality detecting in the printing controlling Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F37X
  • Description: Abnormality detecting in the FAX Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Perform a deed operation check for DIMM Clear by U671.(Since it disappears when received data remain, cautions are required.) * notes (4) Exchange FAX_DIMM and perform an operation check. * Notes (5) Exchange a Main board and perform an operation check. (6) Exchange HDD and perform an operation check. * (7) Get USBLOG and contact service headquarters. * Only HDD standard model * Note Only model which has Flash for FAX data in a Main board
  • Code: F38X
  • Description: Abnormality detecting in the authentication authorized Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F3AX, F3BX, F3CX
  • Description: Abnormality detecting in the Entity Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F3DX, F3EX, F3FX
  • Description: Abnormality detecting in the Entity Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F40X, F41X, F42X
  • Description: Abnormality detecting in the Entity Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F43X, F44X, F45X
  • Description: Abnormality detecting in the Entity Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F46X
  • Description: Abnormality detecting of a printer rendering part
  • Remedy: (1) Exchange boards and perform an operation check. (2) the acquisition wish of USBLOG — carry out (Depending on the (2) case, it is print capture data acquisition) * Only HDD standard model
  • Code: F47X, F48X
  • Description: Abnormality detecting of an image editing processing part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F4DX, F4EX
  • Description: Abnormality detecting in the Entity Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F4FX
  • Description: Abnormality detecting in the JOB Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F50X
  • Description: Abnormality detecting in the FAX Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F51X, F52X, F53X
  • Description: Abnormality detecting in a JOB execution part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F55X, F56X, F57X
  • Description: Abnormality detecting in a JOB execution part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F58X, F59X, F5AX
  • Description: Abnormality detecting in the various-services Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F5BX, F5CX
  • Description: Abnormality detecting in the various-services Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F5DX, F5EX
  • Description: Abnormality detecting in the various-services Management Department
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F5FX
  • Description: Abnormality detecting in a service execution part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F62X
  • Description: Abnormality detecting in a service execution part
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model
  • Code: F63X
  • Description: Abnormality detecting in a device control section
  • Remedy: (1) Initialize HDD and perform an operation check. (FULL of U024) * ( 2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange HDD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only HDD standard model

Ошибки Kyocera ECOSYS M2030dn

Ошибки Kyocera ECOSYS M2030pn

Ошибки Kyocera ECOSYS M2035dn

Ошибки Kyocera ECOSYS M2040dn

Ошибки Kyocera ECOSYS M2135dn

Ошибки Kyocera ECOSYS M2530dn

Ошибки Kyocera ECOSYS M2535dn

Ошибки Kyocera ECOSYS M2540dn

Ошибки Kyocera ECOSYS M2540dw

Ошибки Kyocera ECOSYS M2635dn

Ошибки Kyocera ECOSYS M2635dw

Ошибки Kyocera ECOSYS M2640idw

Ошибки Kyocera ECOSYS M3040dn

Ошибки Kyocera ECOSYS M3040idn

Ошибки Kyocera ECOSYS M3145dn

Ошибки Kyocera ECOSYS M3145idn

Ошибки Kyocera ECOSYS M2735dw

Ошибки Kyocera ECOSYS M3540dn

Ошибки Kyocera ECOSYS M3540idn

Ошибки Kyocera ECOSYS M3550idn

Ошибки Kyocera ECOSYS M3560idn

Ошибки Kyocera ECOSYS M3645dn

Ошибки Kyocera ECOSYS M3645idn

Ошибки Kyocera ECOSYS M3655idn

Ошибки Kyocera ECOSYS M3660idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M4125idn

Ошибки Kyocera ECOSYS M4132idn

Ошибки Kyocera ECOSYS M5521cdn

Ошибки Kyocera ECOSYS M5521cdw

Ошибки Kyocera ECOSYS M5526cdn

Ошибки Kyocera ECOSYS M5526cdw

Ошибки Kyocera ECOSYS M6026cdn

Ошибки Kyocera ECOSYS M6026cidn

Ошибки Kyocera ECOSYS M6030cdn

Ошибки Kyocera ECOSYS M6035cidn

Ошибки Kyocera ECOSYS M6230cidn

Ошибки Kyocera ECOSYS M6235cidn

Ошибки Kyocera ECOSYS M6526cdn

Ошибки Kyocera ECOSYS M6526cidn

Ошибки Kyocera ECOSYS M6530cdn

Ошибки Kyocera ECOSYS M6535cidn

Ошибки Kyocera ECOSYS M6630cidn

Ошибки Kyocera ECOSYS M6635cidn

Ошибки Kyocera ECOSYS M8124cidn

Ошибки Kyocera ECOSYS M8130cidn

Ошибки Kyocera ECOSYS P2035d

Ошибки Kyocera ECOSYS P2040dn

Ошибки Kyocera ECOSYS P2040dw

Ошибки Kyocera ECOSYS P2135d

Ошибки Kyocera ECOSYS P2135dn

Ошибки Kyocera ECOSYS P2235dn

Ошибки Kyocera ECOSYS P2235dw

Ошибки Kyocera ECOSYS P3045dn

Ошибки Kyocera ECOSYS P3050dn

Ошибки Kyocera ECOSYS P3055dn

Ошибки Kyocera ECOSYS P3060dn

Ошибки Kyocera ECOSYS P3145dn

Ошибки Kyocera ECOSYS P3150dn

Ошибки Kyocera ECOSYS P3155dn

Ошибки Kyocera ECOSYS P3160dn

Ошибки Kyocera ECOSYS P3260dn

Ошибки Kyocera ECOSYS P4035dn

Ошибки Kyocera ECOSYS P4040dn

Ошибки Kyocera ECOSYS P5021cdn

Ошибки Kyocera ECOSYS P5021cdw

Ошибки Kyocera ECOSYS P5026cdn

Ошибки Kyocera ECOSYS P5026cdw

Ошибки Kyocera ECOSYS P6021cdn

Ошибки Kyocera ECOSYS P6026cdn

Ошибки Kyocera ECOSYS P6030cdn

Ошибки Kyocera ECOSYS P6035cdn

Ошибки Kyocera ECOSYS P6130cdn

Ошибки Kyocera ECOSYS P6230cdn

Ошибки Kyocera ECOSYS P6235cdn

Ошибки Kyocera ECOSYS P7035cdn

Ошибки Kyocera ECOSYS P7040cdn

Ошибки Kyocera ECOSYS P7240cdn

Ошибки Kyocera ECOSYS P8060cdn

Ошибки Kyocera FS-C8600DN

Ошибки Kyocera FS-C8650DN

Ошибки Kyocera FS1016MFP

Ошибки Kyocera FS1018MFP

Ошибки Kyocera FS1020MFP

Ошибки Kyocera FS1024MFP

Ошибки Kyocera FS1025MFP

Ошибки Kyocera FS1028MFP

Ошибки Kyocera FS1030MFP

Ошибки Kyocera FS1035MFP

Ошибки Kyocera FS1040

Ошибки Kyocera FS1050

Ошибки Kyocera FS1060DN

Ошибки Kyocera FS1100

Ошибки Kyocera FS1110

Ошибки Kyocera FS1116MFP

Ошибки Kyocera FS1118MFP

Ошибки Kyocera FS1120

Ошибки Kyocera FS1120MFP

Ошибки Kyocera FS1124MFP

Ошибки Kyocera FS1125MFP

Ошибки Kyocera FS1128MFP

Ошибки Kyocera FS1130MFP

Ошибки Kyocera FS1135MFP

Ошибки Kyocera FS1200

Ошибки Kyocera FS1220MFP

Ошибки Kyocera FS1300D

Ошибки Kyocera FS1320D

Ошибки Kyocera FS1320MFP

Ошибки Kyocera FS1325MFP

Ошибки Kyocera FS1350DN

Ошибки Kyocera FS1370DN

Ошибки Kyocera FS1500

Ошибки Kyocera FS6020

Ошибки Kyocera FS6025MFP

Ошибки Kyocera FS6025MFPB

Ошибки Kyocera FS6030MFP

Ошибки Kyocera FS6500

Ошибки Kyocera FS6525MFP

Ошибки Kyocera FS6530MFP

Ошибки Kyocera FS6700

Ошибки Kyocera FS6900

Ошибки Kyocera FS6950DN

Ошибки Kyocera FS8000CD

Ошибки Kyocera FS8000CN

Ошибки Kyocera FS8100DN

Ошибки Kyocera TASKalfa 180

Ошибки Kyocera TASKalfa 1800

Ошибки Kyocera TASKalfa 1801

Ошибки Kyocera TASKalfa 181

Ошибки Kyocera TASKalfa 205c

Ошибки Kyocera TASKalfa 220

Ошибки Kyocera TASKalfa 2200

Ошибки Kyocera TASKalfa 2201

Ошибки Kyocera TASKalfa 221

Ошибки Kyocera TASKalfa 2420w

Ошибки Kyocera TASKalfa 2460ci

Ошибки Kyocera TASKalfa 2470ci

Ошибки Kyocera TASKalfa 250ci

Ошибки Kyocera TASKalfa 2510i

Ошибки Kyocera TASKalfa 2520i

Ошибки Kyocera TASKalfa 255

Ошибки Kyocera TASKalfa 2550ci

Ошибки Kyocera TASKalfa 2551ci

Ошибки Kyocera TASKalfa 2552ci

Ошибки Kyocera TASKalfa 2553ci

Ошибки Kyocera TASKalfa 255b

Ошибки Kyocera TASKalfa 255c

Ошибки Kyocera TASKalfa 265ci

Ошибки Kyocera TASKalfa 300ci

Ошибки Kyocera TASKalfa 300i

Ошибки Kyocera TASKalfa 3010i

Ошибки Kyocera TASKalfa 3011i

Ошибки Kyocera TASKalfa 305

Ошибки Kyocera TASKalfa 3050ci

Ошибки Kyocera TASKalfa 3051ci

Ошибки Kyocera TASKalfa 306ci

Ошибки Kyocera TASKalfa 307ci

Ошибки Kyocera TASKalfa 308ci

Ошибки Kyocera TASKalfa 3212i

Ошибки Kyocera TASKalfa 3252ci

Ошибки Kyocera TASKalfa 3253ci

Ошибки Kyocera TASKalfa 3500i

Ошибки Kyocera TASKalfa 3501i

Ошибки Kyocera TASKalfa 350ci

Ошибки Kyocera TASKalfa 3510i

Ошибки Kyocera TASKalfa 3511i

Ошибки Kyocera TASKalfa 3550ci

Ошибки Kyocera TASKalfa 3551ci

Ошибки Kyocera TASKalfa 3552ci

Ошибки Kyocera TASKalfa 3553ci

Ошибки Kyocera TASKalfa 356ci

Ошибки Kyocera TASKalfa 358ci

Ошибки Kyocera TASKalfa 4002i

Ошибки Kyocera TASKalfa 4003i

Ошибки Kyocera TASKalfa 400ci

Ошибки Kyocera TASKalfa 4012i

Ошибки Kyocera TASKalfa 4052ci

Ошибки Kyocera TASKalfa 4053ci

Ошибки Kyocera TASKalfa 406ci

Ошибки Kyocera TASKalfa 408ci

Ошибки Kyocera TASKalfa 420i

Ошибки Kyocera TASKalfa 4500i

Ошибки Kyocera TASKalfa 4501i

Ошибки Kyocera TASKalfa 4550ci

Ошибки Kyocera TASKalfa 4551ci

Ошибки Kyocera TASKalfa 4820w

Ошибки Kyocera TASKalfa 5002i

Ошибки Kyocera TASKalfa 5003i

Ошибки Kyocera TASKalfa 500ci

Ошибки Kyocera TASKalfa 5052ci

Ошибки Kyocera TASKalfa 5053ci

Ошибки Kyocera TASKalfa 508ci

Ошибки Kyocera TASKalfa 520i

Ошибки Kyocera TASKalfa 5500i

Ошибки Kyocera TASKalfa 5501i

Ошибки Kyocera TASKalfa 550c

Ошибки Kyocera TASKalfa 552ci

Ошибки Kyocera TASKalfa 5550ci

Ошибки Kyocera TASKalfa 5551ci

Ошибки Kyocera TASKalfa 6002i

Ошибки Kyocera TASKalfa 6003i

Ошибки Kyocera TASKalfa 6052ci

Ошибки Kyocera TASKalfa 6053ci

Ошибки Kyocera TASKalfa 620

Ошибки Kyocera TASKalfa 6500i

Ошибки Kyocera TASKalfa 6501i

Ошибки Kyocera TASKalfa 650c

Ошибки Kyocera TASKalfa 6550ci

Ошибки Kyocera TASKalfa 6551ci

Ошибки Kyocera TASKalfa 7002i

Ошибки Kyocera TASKalfa 7003i

Ошибки Kyocera TASKalfa 7052ci

Ошибки Kyocera TASKalfa 7353ci

Ошибки Kyocera TASKalfa 750c

Ошибки Kyocera TASKalfa 7550ci

Ошибки Kyocera TASKalfa 7551ci

Ошибки Kyocera TASKalfa 8000i

Ошибки Kyocera TASKalfa 8001i

Ошибки Kyocera TASKalfa 8002i

Ошибки Kyocera TASKalfa 8003i

Ошибки Kyocera TASKalfa 8052ci

Ошибки Kyocera TASKalfa 820

Ошибки Kyocera TASKalfa 8353ci

Ошибки Kyocera TASKalfa 9002i

Ошибки Kyocera TASKalfa 9003i

Японская компания Kyocera производит высококачественные лазерные принтеры и МФУ для офисной печати. Их продукция одна из самых востребованных на сегодняшний день. Ведь печатающие устройства Kyocera характеризуются высокой надежностью, износостойкостью и большим сроком эксплуатации. Однако даже их изделия не являются вечными. Со временем принтеры Kyocera начинают сбоить.

К счастью, оргтехника Kyocera оснащена системой самодиагностики (так же, как и струйные принтеры Canon). Поэтому, в случае возникновения проблемы, устройство самостоятельно выявит уязвимое место и сообщит Вам об этом миганием соответствующего индикатора на панели управления либо кодом ошибки, выведенным на дисплей принтера.

Если Вы не являетесь мастером по обслуживанию принтеров и МФУ Kyocera, то, чтобы понять, о чем сообщает печатающее устройство, Вам потребуется расшифровать указанный им код. Для этого мы добавили в статью таблицу кодов ошибок лазерных принтеров Kyocera серии FS и не только.

код ошибки Kyocera решение проблемы

Код ошибки

Значение ошибки

Решение проблемы

E-0001 (E1)

Поврежден чип картриджа либо установлен неоригинальный картридж.

Замените установленный картридж оригинальной версией изделия. Если хотите сэкономить, тогда купите и установите новый чип на картридж или перепрошейте принтер Kyocera. Однако предварительно не помешает попробовать сбросить ошибку соответствующей комбинацией клавиш (как это сделать, читайте в статье «Сброс ошибки установки неоригинального картриджа в принтерах Kyocera»).

E-0002 (E2)

Регион использования картриджа и принтера не совпадают.

Замените чип или прошейте принтер Kyocera.

E-0003 (E3)

Заполнена память принтера или МФУ Kyocera.

Отпечатайте ранее отсканированные листы или очистите очередь печати нажатием кнопки Стоп/Сброс (ранее отсканированные листы также удалятся из памяти принтера, даже если они еще не были распечатаны).

E-0007 (E7)

Тонер-картридж Kyocera израсходовал ресурс красящего вещества.

Замените или заправьте картридж Kyocera (если используете совместимый или перезаправленный расходник, то после установки его в принтер не забудьте сбросить ошибку зажатием на 3-5 секунды кнопок [Ок] и [Сброс/Стоп]).

E-0008 (E8)

Открыта крышка принтера либо не работает датчик закрытия крышек устройства.

Откройте и еще раз закройте переднюю и заднюю крышку принтера. Во время закрытия Вы должны услышать характерный щелчок. Если не помогло, то причина в неисправности датчика.

E-0009 (E9)

Лоток приема бумаги полон.

Уберите все отпечатанные листы бумаги из выходящего лотка. Чтобы возобновить печать, нажмите кнопку [Старт].

E-0012 (E12)

Ошибка памяти принтера Kyocera.

Попробуйте уменьшить разрешение печати. Скорее всего, формат создаваемого отпечатка не соответствует возможностям принтера.

E-0014 (E14)

Установлен неверный формат бумаги (неподдерживаемый принтером Kyocera).

Поменяйте бумагу на поддерживаемую принтером либо смените ее формат в настройках печати. Попробуйте обновить программное обеспечение. Возможно, это расширит поддерживаемые принтером Kyocera форматы.

E-0015 (E15)

Устройство не подключено к электрической сети либо на компьютере нет (не работает) драйвера принтера Kyocera.

Проверьте подключение печатающего аппарата к электрической сети, а также целостность кабеля. Если ошибка не исчезает, скачайте драйвер принтера Kyocera и установите его на компьютер.

E-0017 (E17)

Ошибка передачи данных.

Проверьте подключение принтера к компьютеру. Кабель не должен быть длиннее 5 метров, а также обязан поддерживать стандарт USB 2.0. Кроме того, переустановите драйвер принтера и утилиту Kyocera Client Tool.

E-0018 (E18)

Очередь печати заполнена.

Очистите очередь печати нажатием кнопки [Сброс] либо через драйвер принтера.

E-0019 (E19)

Неверный формат печати.

Отмените печать нажатием кнопки [Стоп/Сброс]. Выберите в настройках принтера соответствующий режим печати, а также установите в лоток поддерживаемый принтером формат бумаги.

J-0000 (jam0000)

Замятие бумаги за задней крышкой.

Откройте крышку и извлеките бумагу. Проверьте надежность крепления бумаги в лотке, а также принтер на наличие посторонних предметов. Еще причина может быть в пружине выходного флажка. Если она растянулась, то может плохо работать фиксатор. Также проблема может быть из-за печки, сделайте ее ревизию, переборку и смазку.

J-0501 (jam0501)

Бумага застряла в принтере Kyocera

Извлеките замятую бумагу. Проверьте надежность установки бумаги во входной лоток. Проверьте целостность роликов протяжки бумаги, а также принтер на наличие посторонних предметов. Если не помогло, стоит внимательно осмотреть ребра на направляющей пластине. На них могут образоваться сколы, трещины и заусенцы. Их можно слегка подчистить наждачной бумагой (нулевкой).

J-0511 (jam0511)

Принтер Kyocera замял бумагу.

Извлеките замятую бумагу и повторите печать. Если проблема не исчезла, несите принтер в сервис. Скорее всего, изношен ролик протяжки бумаги.

C7990

Бункер драм-картриджа (блока фотобарабана) заполнен отработанным тонером либо неисправен счетчик отработки красящего вещества. Еще проблема может быть в главной плате PWB.

Осуществите чистку драм-картриджа (блока фотобарабана). Если проблема в датчике или плате, то нужно отнести принтер в СЦ на диагностику.

F248

Ошибка обработки отпечатываемого материала.

Перезагрузите принтер. Уберите неподдерживаемые спецсимволы из отпечатка. Обновите ПО принтера Kyocera. Смените режим работы принтера с PDL на GDI (Пуск -> Принтеры -> Свойства -> Параметры устройства).

PF

Отсутствует бумага в лотке подачи.

Загрузите листы бумаги во входной лоток. Если принтер по-прежнему не печатает, значит нужно искать проблему в чем-то другом.

1101

Ошибка сканирования через сеть из-за неправильного имени SMTP сервера.

Пропишите DNS-адреса помимо прочих настроек печати по сети.

1102

Некорректная настройка сканера для работы через сеть

Зайдите в Web-панель управления принтером (нужно в адресную строку браузера ввести iP принтера Kyocera). Далее в зависимости от модели введите логин и пароль (Admin/Admin или просто admin00 без логина). Далее следуйте инструкции:

  • Откройте вкладку «Сканер» и установите настройки по умолчанию;
  • Перейдите на вкладку «Основные», выберите адресную книгу и нажмите добавить контакт;
  • В открывшемся окне найдите блок SMB и введите: имя хоста = имя компьютера или его iP-адрес, путь = название сетевой папки (если не расшарена, то вместе с ИП-адресом), имя пользователя = user или domainuser (в зависимости от типа профиля), пароль = пароль.

Логин и пароль нужны обязательно, если их нет, то следует создать.

2101

Ошибка передачи данных при сканировании через сеть.

Правильно настройте параметры (как для ошибки 1102), только предварительно отключите на ПК антивирус и брандмауэр.

Если Вы испытали все способы, но не смогли убрать ошибку, то следует нести печатающее устройство в сервисный центр. Кроме того, есть ряд ошибок (высвечиваемых на дисплее принтера), которые нельзя устранить в домашних условиях. Соответствующие коды ошибок принтеров Kyocera представляем в очередной таблице.

Коды ошибок принтеров и МФУ Kyocera, которые нужно устранять в сервисном центре

Код ошибки

Значение ошибки

Решение проблемы

0030

Неисправность платы управления факсом принтера.

Замена платы.

0100

Неисправность платы управления или флеш-памяти принтера.

Замена платы.

0120

Ошибка чтения mac-адреса из-за неисправности флеш-памяти принтера.

Замена платы.

0190

Неисправность платы управления или флеш-памяти принтера.

Замена платы.

0630

Неисправность платы управления принтера.

Замена платы.

1020

Неисправность мотора, привода или отсутствие контакта.

Разборка принтера и замена изношенных частей. Проверка надежности подключений, замена разорванных (прогоревших) кабелей. Ремонт или замена привода мотора.

1040

Неисправность мотора, привода или отсутствие контакта.

Разборка принтера и замена изношенных частей. Проверка надежности подключений, замена разорванных (прогоревших) кабелей. Ремонт или замена привода мотора.

2000

Неисправность главной платы управления, соединительного кабеля или привода принтера.

Проверить ремни, шестерни и ролики привода. Смазать или заменить, если есть дефекты. Заменить привод или главную плату.

3100 (C3100)

Неисправность главной платы, привода сканера, датчика положения или нарушение целостности соединений.

Проверить наличие разрывов и отсутствия контакта. Смазать или заменить изношенные элементы привода. Заменить привод, главную плату, датчик или соединительный кабель. Если Вам повезло, то возможно забыли отключить фиксатор блока сканера.

3101

Сетевой кабель не подсоединен, или нарушена работа концентратора. Еще может быть из-за наличия вирусов в системе или неправильно заданным параметрам сервера SMTP.

Проверить соединения, правильно настроить параметры сети.

3300

Неисправность главной платы, датчика CIS или соединительного кабеля.

Проверить контакты, заменить плату или датчик.

3500

Неисправность главной платы или нарушение соединения контактов.

Проверить контакты, заменить плату.

4000 (C4000)

Неисправность главной платы, привода сканера или нарушение соединений. Однако чаще всего ошибка лазера.

Проверить контакты, заменить плату или привод блока сканера. Почистить лазер, смазать ось полигон-мотора, либо полностью заменить блок лазера.

4200

Неисправность главной платы, блока сканера или датчика BD.

Отключить питание принтера на 30 минут. Если не помогло, то следует заменить привод сканера или главную плату принтера.

6000 (С6000)

Неисправность главной платы, термостата, печки или нарушение соединения контактов.

Проверить и поправить контакты. Заменить фьюзер. Ремонт или замена печки, термодатчика, термопредохранителя и т.д.

6020

Сгорание термистора или главной платы.

Замена термистора или главной платы.

6030

Неисправность главной платы, термостата или термистора. Возможно, причина в отсутствии контакта.

Проверить соединения. Заменить плату, термостат или термистор.

6400

Неисправность главной платы, отсутствие питания или контакта.

Заменить плату или источник питания.

F000

Неисправность главной платы или отсутствие контакта.

Проверить соединение ремня безопасности. Заменить ремень или плату управления.

F020

Неисправность элементов памяти принтера.

Перезагрузить принтер. Если ошибка не устранилась – заменить плату управления.

F040

Неисправность главной платы принтера.

Перезагрузить принтер. Если ошибка не устранилась – заменить плату управления.

F05D

Неисправность главной платы. Сбой программного оборудования привода. Проблемы с прошивкой принтера Kyocera.

Перезагрузить принтер. Если ошибка не устранилась – заменить плату управления. Перепрошить принтер Kyocera.

F245 F246 F247 F375

Принтер Kyocera заблокирован из-за проблемы, вызванной отказом источника питания.

Нужно перепрошить принтер специальной сервисной микропрограммой.

Обратите внимание: Если у печатающего устройства нет дисплея, то определить проблему можно по светодиодным индикаторам, встроенным в панель управления принтером. Например, у Kyocera Ecosys P2135D нужно сосчитать количество миганий индикаторов красного цвета и таким образом определить число, указывающее на ту или иную ошибку. В свою очередь, у модели Kyocera FS-1040 все зависит от темпа мигания светодиода с надписью «Внимание!» («Attention!»):

  • Мигает медленно – указывает на отсутствие бумаги в лотке или тонера в картридже.
  • Мигает быстро – оповещает о проблеме с памятью устройства, переполненном лотке или замятии бумаги, а также об использовании неоригинальных расходных материалов.
  • Горит постоянно – говорит о проблемах с картриджем или фотобарабаном либо указывает на открытые крышки принтера.

ошибки принтера Kyocera

Чтобы потребитель мог наверняка определить проблему, рекомендуем использовать утилиту Kyocera Client Tool, которая идет в комплекте с драйверами принтера.


Ваше Имя:


Ваш вопрос:


Внимание: HTML не поддерживается! Используйте обычный текст.


Оценка:


Плохо
 

 

Хорошо


Введите код, указанный на картинке:


Ошибки Kyocera ECOSYS M2030dn

Ошибки Kyocera ECOSYS M2030pn

Ошибки Kyocera ECOSYS M2035dn

Ошибки Kyocera ECOSYS M2040dn

Ошибки Kyocera ECOSYS M2135dn

Ошибки Kyocera ECOSYS M2530dn

Ошибки Kyocera ECOSYS M2535dn

Ошибки Kyocera ECOSYS M2540dn

Ошибки Kyocera ECOSYS M2540dw

Ошибки Kyocera ECOSYS M2635dn

Ошибки Kyocera ECOSYS M2635dw

Ошибки Kyocera ECOSYS M2640idw

Ошибки Kyocera ECOSYS M3040dn

Ошибки Kyocera ECOSYS M3040idn

Ошибки Kyocera ECOSYS M3145dn

Ошибки Kyocera ECOSYS M3145idn

Ошибки Kyocera ECOSYS M2735dw

Ошибки Kyocera ECOSYS M3540dn

Ошибки Kyocera ECOSYS M3540idn

Ошибки Kyocera ECOSYS M3550idn

Ошибки Kyocera ECOSYS M3560idn

Ошибки Kyocera ECOSYS M3645dn

Ошибки Kyocera ECOSYS M3645idn

Ошибки Kyocera ECOSYS M3655idn

Ошибки Kyocera ECOSYS M3660idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M4125idn

Ошибки Kyocera ECOSYS M4132idn

Ошибки Kyocera ECOSYS M5521cdn

Ошибки Kyocera ECOSYS M5521cdw

Ошибки Kyocera ECOSYS M5526cdn

Ошибки Kyocera ECOSYS M5526cdw

Ошибки Kyocera ECOSYS M6026cdn

Ошибки Kyocera ECOSYS M6026cidn

Ошибки Kyocera ECOSYS M6030cdn

Ошибки Kyocera ECOSYS M6035cidn

Ошибки Kyocera ECOSYS M6230cidn

Ошибки Kyocera ECOSYS M6235cidn

Ошибки Kyocera ECOSYS M6526cdn

Ошибки Kyocera ECOSYS M6526cidn

Ошибки Kyocera ECOSYS M6530cdn

Ошибки Kyocera ECOSYS M6535cidn

Ошибки Kyocera ECOSYS M6630cidn

Ошибки Kyocera ECOSYS M6635cidn

Ошибки Kyocera ECOSYS M8124cidn

Ошибки Kyocera ECOSYS M8130cidn

Ошибки Kyocera ECOSYS P2035d

Ошибки Kyocera ECOSYS P2040dn

Ошибки Kyocera ECOSYS P2040dw

Ошибки Kyocera ECOSYS P2135d

Ошибки Kyocera ECOSYS P2135dn

Ошибки Kyocera ECOSYS P2235dn

Ошибки Kyocera ECOSYS P2235dw

Ошибки Kyocera ECOSYS P3045dn

Ошибки Kyocera ECOSYS P3050dn

Ошибки Kyocera ECOSYS P3055dn

Ошибки Kyocera ECOSYS P3060dn

Ошибки Kyocera ECOSYS P3145dn

Ошибки Kyocera ECOSYS P3150dn

Ошибки Kyocera ECOSYS P3155dn

Ошибки Kyocera ECOSYS P3160dn

Ошибки Kyocera ECOSYS P3260dn

Ошибки Kyocera ECOSYS P4035dn

Ошибки Kyocera ECOSYS P4040dn

Ошибки Kyocera ECOSYS P5021cdn

Ошибки Kyocera ECOSYS P5021cdw

Ошибки Kyocera ECOSYS P5026cdn

Ошибки Kyocera ECOSYS P5026cdw

Ошибки Kyocera ECOSYS P6021cdn

Ошибки Kyocera ECOSYS P6026cdn

Ошибки Kyocera ECOSYS P6030cdn

Ошибки Kyocera ECOSYS P6035cdn

Ошибки Kyocera ECOSYS P6130cdn

Ошибки Kyocera ECOSYS P6230cdn

Ошибки Kyocera ECOSYS P6235cdn

Ошибки Kyocera ECOSYS P7035cdn

Ошибки Kyocera ECOSYS P7040cdn

Ошибки Kyocera ECOSYS P7240cdn

Ошибки Kyocera ECOSYS P8060cdn

Ошибки Kyocera FS-C8600DN

Ошибки Kyocera FS-C8650DN

Ошибки Kyocera FS1016MFP

Ошибки Kyocera FS1018MFP

Ошибки Kyocera FS1020MFP

Ошибки Kyocera FS1024MFP

Ошибки Kyocera FS1025MFP

Ошибки Kyocera FS1028MFP

Ошибки Kyocera FS1030MFP

Ошибки Kyocera FS1035MFP

Ошибки Kyocera FS1040

Ошибки Kyocera FS1050

Ошибки Kyocera FS1060DN

Ошибки Kyocera FS1100

Ошибки Kyocera FS1110

Ошибки Kyocera FS1116MFP

Ошибки Kyocera FS1118MFP

Ошибки Kyocera FS1120

Ошибки Kyocera FS1120MFP

Ошибки Kyocera FS1124MFP

Ошибки Kyocera FS1125MFP

Ошибки Kyocera FS1128MFP

Ошибки Kyocera FS1130MFP

Ошибки Kyocera FS1135MFP

Ошибки Kyocera FS1200

Ошибки Kyocera FS1220MFP

Ошибки Kyocera FS1300D

Ошибки Kyocera FS1320D

Ошибки Kyocera FS1320MFP

Ошибки Kyocera FS1325MFP

Ошибки Kyocera FS1350DN

Ошибки Kyocera FS1370DN

Ошибки Kyocera FS1500

Ошибки Kyocera FS6020

Ошибки Kyocera FS6025MFP

Ошибки Kyocera FS6025MFPB

Ошибки Kyocera FS6030MFP

Ошибки Kyocera FS6500

Ошибки Kyocera FS6525MFP

Ошибки Kyocera FS6530MFP

Ошибки Kyocera FS6700

Ошибки Kyocera FS6900

Ошибки Kyocera FS6950DN

Ошибки Kyocera FS8000CD

Ошибки Kyocera FS8000CN

Ошибки Kyocera FS8100DN

Ошибки Kyocera TASKalfa 180

Ошибки Kyocera TASKalfa 1800

Ошибки Kyocera TASKalfa 1801

Ошибки Kyocera TASKalfa 181

Ошибки Kyocera TASKalfa 205c

Ошибки Kyocera TASKalfa 220

Ошибки Kyocera TASKalfa 2200

Ошибки Kyocera TASKalfa 2201

Ошибки Kyocera TASKalfa 221

Ошибки Kyocera TASKalfa 2420w

Ошибки Kyocera TASKalfa 2460ci

Ошибки Kyocera TASKalfa 2470ci

Ошибки Kyocera TASKalfa 250ci

Ошибки Kyocera TASKalfa 2510i

Ошибки Kyocera TASKalfa 2520i

Ошибки Kyocera TASKalfa 255

Ошибки Kyocera TASKalfa 2550ci

Ошибки Kyocera TASKalfa 2551ci

Ошибки Kyocera TASKalfa 2552ci

Ошибки Kyocera TASKalfa 2553ci

Ошибки Kyocera TASKalfa 255b

Ошибки Kyocera TASKalfa 255c

Ошибки Kyocera TASKalfa 265ci

Ошибки Kyocera TASKalfa 300ci

Ошибки Kyocera TASKalfa 300i

Ошибки Kyocera TASKalfa 3010i

Ошибки Kyocera TASKalfa 3011i

Ошибки Kyocera TASKalfa 305

Ошибки Kyocera TASKalfa 3050ci

Ошибки Kyocera TASKalfa 3051ci

Ошибки Kyocera TASKalfa 306ci

Ошибки Kyocera TASKalfa 307ci

Ошибки Kyocera TASKalfa 308ci

Ошибки Kyocera TASKalfa 3212i

Ошибки Kyocera TASKalfa 3252ci

Ошибки Kyocera TASKalfa 3253ci

Ошибки Kyocera TASKalfa 3500i

Ошибки Kyocera TASKalfa 3501i

Ошибки Kyocera TASKalfa 350ci

Ошибки Kyocera TASKalfa 3510i

Ошибки Kyocera TASKalfa 3511i

Ошибки Kyocera TASKalfa 3550ci

Ошибки Kyocera TASKalfa 3551ci

Ошибки Kyocera TASKalfa 3552ci

Ошибки Kyocera TASKalfa 3553ci

Ошибки Kyocera TASKalfa 356ci

Ошибки Kyocera TASKalfa 358ci

Ошибки Kyocera TASKalfa 4002i

Ошибки Kyocera TASKalfa 4003i

Ошибки Kyocera TASKalfa 400ci

Ошибки Kyocera TASKalfa 4012i

Ошибки Kyocera TASKalfa 4052ci

Ошибки Kyocera TASKalfa 4053ci

Ошибки Kyocera TASKalfa 406ci

Ошибки Kyocera TASKalfa 408ci

Ошибки Kyocera TASKalfa 420i

Ошибки Kyocera TASKalfa 4500i

Ошибки Kyocera TASKalfa 4501i

Ошибки Kyocera TASKalfa 4550ci

Ошибки Kyocera TASKalfa 4551ci

Ошибки Kyocera TASKalfa 4820w

Ошибки Kyocera TASKalfa 5002i

Ошибки Kyocera TASKalfa 5003i

Ошибки Kyocera TASKalfa 500ci

Ошибки Kyocera TASKalfa 5052ci

Ошибки Kyocera TASKalfa 5053ci

Ошибки Kyocera TASKalfa 508ci

Ошибки Kyocera TASKalfa 520i

Ошибки Kyocera TASKalfa 5500i

Ошибки Kyocera TASKalfa 5501i

Ошибки Kyocera TASKalfa 550c

Ошибки Kyocera TASKalfa 552ci

Ошибки Kyocera TASKalfa 5550ci

Ошибки Kyocera TASKalfa 5551ci

Ошибки Kyocera TASKalfa 6002i

Ошибки Kyocera TASKalfa 6003i

Ошибки Kyocera TASKalfa 6052ci

Ошибки Kyocera TASKalfa 6053ci

Ошибки Kyocera TASKalfa 620

Ошибки Kyocera TASKalfa 6500i

Ошибки Kyocera TASKalfa 6501i

Ошибки Kyocera TASKalfa 650c

Ошибки Kyocera TASKalfa 6550ci

Ошибки Kyocera TASKalfa 6551ci

Ошибки Kyocera TASKalfa 7002i

Ошибки Kyocera TASKalfa 7003i

Ошибки Kyocera TASKalfa 7052ci

Ошибки Kyocera TASKalfa 7353ci

Ошибки Kyocera TASKalfa 750c

Ошибки Kyocera TASKalfa 7550ci

Ошибки Kyocera TASKalfa 7551ci

Ошибки Kyocera TASKalfa 8000i

Ошибки Kyocera TASKalfa 8001i

Ошибки Kyocera TASKalfa 8002i

Ошибки Kyocera TASKalfa 8003i

Ошибки Kyocera TASKalfa 8052ci

Ошибки Kyocera TASKalfa 820

Ошибки Kyocera TASKalfa 8353ci

Ошибки Kyocera TASKalfa 9002i

Ошибки Kyocera TASKalfa 9003i

C0030 Системная ошибка в управлении факсом Обработка при помощи программного обеспечения факса была отключена из за проблем с оборудованием Неисправность в системе управления факсом PWB Заменить систему управления факсом PWB C0070 Обнаружена несовместимость платы управления PWB Обнаружена несовместимость при первичной инициализации системы управления факсом PWB. Никакие команды связи не проходят. Дефект программного обеспечения факса Установить программное обеспечение для факса C0100 Ошибка при резервном копировании памяти устройства Неисправна флеш память Заменить плату управления PWB C0120 Ошибка данных MAC адреса Неисправность в плате управления PWB Заменить плату управления PWB C0130 Ошибка чтения/записи при резервном копировании Неисправна флеш память Заменить плату управления PWB C0140 Ошибка при резервном копировании данных Неисправна флеш память Заменить плату управления PWB C0150 Ошибка EEPROM платы управления PWB Обнаружена ошибка связи PWB EEPROM (U17) Неправильная установка PWB EEPROM (U17) Проверить установку EEPROM (U17) и при необходимости исправить C0170 Ошибка счетчика 1. Неисправность control PWB.

2. Повреждения данных PWB EEPROM (U17)

1. Заменить плату управления PWB.

2. Обратиться в сервис обслуживания

C0180 Номер аппарата не совпадает Основной номер и номер двигателя не совпадают 1. Основная PWB или PWB двигателя была заменена.

2. Повреждения данных PWB EEPROM (U17)

1. U004 Задать номер.

2. Обратиться в сервис обслуживания

C0420 Ошибка связи с системой подачи бумаги Ошибка коммуникации между платой PWB  и дополнительным устройством подачи бумаги 1. Неправильная установка устройства подачи бумаги

2. Повреждение провода между платой PWB (YC30) и интерфесным разъемом устройства подачи, либо разъем подключен неправильно.

3. Неисправен кабель между PF основной PWB и подачей бумаги, либо разъем не вставлен. Плата PF неисправна.

4. Неисправность control PWB

1. Еще раз внимательно прочитайте инструкцию по установке.

2. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

3. Убедитесь, что разъем подключен, а кабель не поврежден.Заменить печатную плату.

4. Заменить плату управления PWB.

C0830 Ошибка контрольной суммы прошивки FAX control PWB Произошла ошибка контрольной суммы программы управления FAX control PWB 1. Дефект программного обеспечения факса.

2. Неисправность в системе управления факсом PWB

1. Установить программное обеспечение для факса.

2. Заменить плату управления факсом PWB

C0840 Неисправность RTС Расхождение во времени между RTC  и текущим пять и более лет. 1. Неисправность control PWB

2. Отсоединена батарея.

1. Заменить плату управления PWB.

2. Визуально проверить и при необходимости исправить.

C0870 Проблема передачи данных большой емкости между FAX control PWB и control PWB Не выполняется передача данных между FAX control PWB и control PWB, даже при повторе через заданный промежуток  Неправильная установка  FAX control PWB Переставить FAX control PWB C0920 Ошибка файловой системы факса Резервное копирование данных не производится по причине ошибки файловой системы флеш-памяти Неисправность в системе управления факсом PWB Заменить плату управления факсом PWB C2000 Ошибка главного двигателя Главный двигатель не выходит на готовность в течение 2 секунд после включения 1. Неисправен кабель между основным двигателем (CN1) и платой PWB (YC17) или разъем вставлен неправильно.

2. Неисправен привод основного двигателя.

3. Неисправен двигатель.

4. Неисправность control PWB

1. Вставьте разъем. Проверьте целостность кабеля.

2. Проверьте плавность вращения роликов и шестерней. При необходимости смажьте. Убедитесь в отсутсвии разрывов передач.

3. Заменить.

4. Заменить.

C2610 Ошибка дигателя устройства подачи бумаги Двигатель устройства подачи бумаги лотка 2 не выходит на готовность более чем через 2 секунды после включения. Неисправность кабеля между двигателем устройства подачи бумаги и control PWB (YC4).  Вставьте разъем. Проверьте целостность кабеля (Обратитесь к инструкции) C2620 Ошибка дигателя устройства подачи бумаги Двигатель устройства подачи бумаги лотка 3 не выходит на готовность более чем через 2 секунды после включения. Неисправность кабеля между двигателем устройства подачи бумаги и control PWB (YC4). Вставьте разъем. Проверьте целостность кабеля (Обратитесь к инструкции) C3100 Ошибка исходного положения ISU 1. Неисправность FFC между CCD PWB (YC1) и control PWB (YC8).

2. Неисправность FFC между control PWB (YC6) и сканера WPB (YC103) или неправильная установка FCC.

3. Неисправность датчика исходного положения.

4. Неисправность кабеля между двигателем ISU и сканером PWB (YC104) или разъем вставлен неправильно.

1. Заменить блок сканера ISU

2. Переставить FFC. Проверить на разрыв, при необходимости заменить.

3. Заменить датчик.

4. Вставьте разъем. Проверьте целостность кабеля.

C3200 Ошибка лампы экспозиции Лампа экспозиции не включается 1. Повреждения FFC между сканером PWB (YC103) и control PWB (YC6), либо некорректная установка FFC.

2. Повреждения FFC между CCD PWB (YC1) и control PWB (YC8).

3. Неисправен кабель между CCD PWB (YC3) и LED приводом PWB (YC1) либо разъем не подключен.

4. Неисправен кабель между LED приводом PWB (YC2) и лампой экспонирования.

5. Лампа экспонирования вышла из строя.

6. Неисправен светодиодный привод.

1. Переустановите FFC. Проверьте целостность, при необходимости замените.

2. Заменить блок сканера.

3. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

4. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

5. Заменить лампу.

6. Заменить привод.

C3300 Ошибка AGC 1. Повреждения FFC между CCD PWB (YC1) и control PWB (YC8).

2. Лампа экспонирования вышла из строя.

3. Неисправность CCD PWB

4. Неисправность control PWB

1. Заменить блок сканера.

2. Заменить лампу.

3. Заменить CCD PWB

4. Заменить control PWB

C3500 Ошибка связи CPU — ASIC (CCD PWB) Обнаружен код ошибки 1. Повреждения FFC между CCD PWB (YC1) и control PWB (YC8).

2. Неисправность CCD PWB.

3. Неисправность control PWB

1. Заменить блок сканера (ISU).

2. Заменить CCD PWB

3. Заменить control PWB

C4000 Ошибка полигон-мотора (блока лазерного сканера) Полигон-мотор не выходит на готовность после 6 секунд после включения. 1. Поврежден кабель между полигон-мотором и control PWB (YC10) или разъем не вставлен.

2. Неисправен блок лазерного сканера.

3. Неисправность control PWB

1. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

2. Заменить блок сканера.

3. Заменить control PWB

C4200 Ошибка BD  (блока лазерного сканера) 1. BD датчик не обнаруживает лазерный луч из-за скопления конденсата на зеркале.

2. Неисправен блок лазерного сканера.

1. Выключите питание машины минимум на 30 минут, затем снова включите, если это не помогает необходимо менять блок сканера.

2. Заменить блок сканера.

C6000 Выход из строя термо-элемента (фьюзера) Температура фьюзера не поднимается после включения устройства. 1. Плохой контакт клемм термистора фьюзера.

2. Плохой контакт в местах подключения нагревателя термоблока.

3. Термисторы фьюзера установлены неправильно.

4 . Срабатывает термореле

5. Нагреватель фьюзера установлен неправильно

6. Выход из строя термо-элемента

1. Проверьте контакты.

2. Проверьте контакты.

3. Заменить блок закрепления

4. Заменить блок закрепления

5. Заменить блок закрепления

6. Заменить блок закрепления

C6020 Слишком высокая температура фьюзера Термистор фьюзера обнаружил аномально высокую температуру. Пробой термистора фьюзера Заменить блок закрепления C6030 Поврежден шлейф термистора термоэлемента Значени на входе термистора равно 0 1. Плохой контакт в клеммах термистора.

2. Неисправен шлейф термистора

3. Термистор установлен некорректно

4. Срабатывает термореле

Проверить контакты

Заменить блок закрепления

C6400 Ошибка пересечения нуля Сигнал пересечения нуля не достигает контрольной платы за указанное время 1. Неисправен кабель между PWB высокого напряжения(YC202) и control PWB (YC23) или разъем не вставлен

2. Дефект соединения между источником питания PWB (YC103) и PWB высокого напряжения (YC201)

3. Неисправен источник питания PWB

4. Неисправность control PWB

1. Переподключите коннектор.Убедитесь что кабель не поврежден.

2. Переподключите коннектор

3. Заменить источник питания

4. Заменить control PWB

C7990 Бункер отработки переполнен Датчик тонера обнаружил, что бункер для отработки переполнен 1. Бункер отработки драм-юнита переполнен.

2. Неисправен датчик отработки

3. Неисправность control PWB

1. Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла замените драм-юнит.

2. Замените датчик.

3. Заменить control PWB

4. Очистите драм юнит (инструкция по очистке бункера отработанного тонера)

F000 Ошибка связи control PWB — панель управления PWB 1. Неисправность соединения панели управления PWB (YC1) и control PWB (YC7).

2. Неисправность панели управления

3. Неисправность control PWB

1. Переподключите коннектор.Убедитесь что кабель не поврежден.

2. Замените панель.

3. Заменить control PWB

F020 Ошибка контрольной суммы RAM control PWB 1. Неисправность основной микросхемы памяти (ОЗУ) на главной плате управления PWB

2. Неисправность платы расширения памяти (DIMM)

1. Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

2. Замените плату расширения (DIMM)

F040 Ошибка связи control PWB двигателя Обнаружена ошибка связи Неисправность control PWB Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB F041 Ошибка связи между гланой платой управления и платой управления сканером Обнаружена ошибка связи Неисправна главная плата управления или управления сканером Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB или scanner PWB F050 Ошибка контрольной суммы платы управления двигателем 1. Такие ошибки могут происходить при обновлении прошивки control PWB

2. Неисправность control PWB

1. Скачайте прошивку снова

2. Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

F186 Ошибка управления видеоданными главной панели управления Неисправность control PWB Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

Японский бренд Kyocera предлагает покупателям отличную качественную копировальную и печатающую технику. Ее можно использовать как дома, так и в офисе. Но что делать, если появились ошибки принтера Kyocera FS 1020 MFP или других моделей? Ведь печатать или сканировать нужно почти каждый день, и работа сильно задерживается из-за неисправностей. Рассмотрим основные проблемы и то, как можно их исправить самостоятельно.

Принтер Kyocera

Принтер Kyocera

Самые распространенные коды ошибок принтеров Kyocera

Слово «ошибка» в английском языке будет «error», поэтому практически все коды начинаются с заглавной Е.

Итак, какие же ошибки могут возникнуть в принтерах Kyocera FS 1020MFP японского производства:

1.Е-0002. Обозначает, что картридж с тонером не подходит устройству по региональной спецификации. Нужно использовать другой картридж.
2.Е-0003. Эта ошибка указывает на переполнение памяти сканера. Вам будут доступны только последние отсканированные изображения. Чтобы устранить ошибку Е-0003, нужно очистить память сканера. Для этого нажать Стоп/Сброс.

Очистка памяти

Очистка памяти

3.Е-0007. Означает, что не хватает краски для печатания. Исправляется код 07 просто – нужно добавить тонер.
4.При открытой задней или передней крышке МФУ Kyocera не работает и выдает ошибку с кодом Е-0008.
5.После печатания или копирования большого количества бумаги (сто листов), если лоток не освободить, появится ошибка Е-0009 принтера Kyocera. Нужно извлечь листы и нажать для продолжения работы кнопку Старт.
6.Иногда выдается код Е-0012, который означает, что задание невозможно выполнить по причине нехватки оперативной памяти. Для решения проблемы нужно сменить разрешающую способность печати с 1200 на 600. Как это сделать, описано в инструкции.
7.При появлении кода Е-0014 нужно положить во входной лоток бумагу необходимого формата. Размер листов определяется драйвером принтера.
8.Если вы забыли подсоединить сетевой или USB-кабель, принтер выдаст ошибку с кодом Е-0015. Нужно нажать Стоп/Сброс, подключить кабель и еще раз нажать эту кнопку.

Замена тубы с тонером

Замена тубы с тонером

В японских принтерах Kyocera FS 1020MFP могут возникать ошибки и описанные в предыдущем разделе, и специфические. Обо всех кодах можно узнать из инструкции по эксплуатации.

Код C7990

Этот номер ошибки в моделях типа FS 1020MFP указывает на поступление сигнала о том, что резервуар тонера переполнен.

Ошибка C7990

Ошибка C7990

Причин для ошибки C7990 может быть три:

•неисправна плата PWB;
•неисправен сенсор количества краски;
•бункер действительно переполнен – рекомендуется заменить блок фотобарабана.

Блок фотобарабана

Блок фотобарабана

В первых двух случаях нужно обращаться в сервисный центр.

В третьем же случае появления кода C7990, если ресурс барабана еще не закончен, можно очистить бункер от краски. Делают это так:

1.Открывают переднюю крышку и вытаскивают блок проявки.
2.Достают фотобарабан.
3.Аккуратно открывают крышку бункера и удаляют краску.
4.Собирают аппарат в обратном порядке.

Как видно, ошибка С7990 принтера Kyocera легко устраняется самостоятельно, и обращаться к специалистам нужно лишь тогда, когда действительно неисправны платы.

Основные ошибки принтеров Kyocera

Другие неисправности

Возможно появление и таких кодов:

•C-F040. Нужно выключить и снова включить прибор путем нажатия кнопки питания.
•J-0511. Код свидетельствует о том, что бумага застряла под задней крышкой. Инструкция описывает, как извлечь бумагу, в соответствующем разделе.
•PF. Принтер сигнализирует о том, что нужно добавить листов во входной лоток.

Основные ошибки принтеров Kyocera

Как видно, принтеры японской компании Kyocera редко ломаются. В основном ошибки выдаются из-за неправильной или невнимательной эксплуатации. Поправить их можно и самостоятельно, но если вы не уверены в своих силах, лучше обратитесь к специалисту.

Likes Likes:  0

Dislikes Dislikes:  0

  1. 01-27-2013

    #1

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    30

    TASKalfa 500ci C7103,C7903 and C7904

    The inital call resulted in a copy quality issue and the fuser and transfer belt were replaced.
    Later a C7103 toner snsor M so drum and developer were replaced. No joy there.
    Next the sub front and main front pcb were changed followed by the Engine pcb.
    Now the code is a C904 yellow drum eprom.
    The components changed as mentioned above were reinstalled in another machine and work fine.
    I think the next step will be changing all developers and drums to see if the machine comes to a ready state.

    Any thoughts or suggestions would be appreciated.
    Thanks in advance and I will post the final resolution to the problem.


  2. 01-27-2013

    #2

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Quote Originally Posted by EDSNOW
    View Post

    The inital call resulted in a copy quality issue and the fuser and transfer belt were replaced.
    Later a C7103 toner snsor M so drum and developer were replaced. No joy there.
    Next the sub front and main front pcb were changed followed by the Engine pcb.
    Now the code is a C904 yellow drum eprom.
    The components changed as mentioned above were reinstalled in another machine and work fine.
    I think the next step will be changing all developers and drums to see if the machine comes to a ready state.

    Any thoughts or suggestions would be appreciated.
    Thanks in advance and I will post the final resolution to the problem.

    I’m assuming two things:
    1) C904 is really C7904
    2) you’ve re-seated all the connectors on the sub front and main front PWBs. Were these parts new or scavenged? Are the connector pins intact (not bent or slipping out of the connector)?

    If these parts were new, then yes try the yellow drum. Are there any other errors recorded?
    I wouldn’t have done anything differently. =^..^=

    If you’d like a serious answer to your request:
    1) demonstrate that you’ve read the manual
    2) demonstrate that you made some attempt to fix it.
    3) if you’re going to ask about jams include the jam code.
    4) if you’re going to ask about an error code include the error code.
    5) You are the person onsite. Only you can make observations.

    blackcat: Master Of The Obvious =^..^=


  3. 01-27-2013

    #3

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    30

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Hi Blackcat
    The main and subboards were from our 400ci at the office.
    The boards from the down machine were reinstalled in our unit and work fine.
    I do appreciate your quick response and the new c-7904 yellow drum eprom is what is showing at the moment.
    The tech spent most od Friday at this site.
    Thanks


  4. 01-27-2013

    #4

    Lightbulb Re: TASKalfa 500ci C7103,C7903 and C7904

    This Parts & Service Manual can now be purchased for $12.77 and downloaded immediately after payment from:

    Just Manuals, The Internet’s largest selection of manuals ~ Instant Downloads

    Paul@justmanuals.com


  5. 01-28-2013

    #5

    Re: TASKalfa 500ci C7103,C7903 and C7904

    The new developers will not operate with older firmware, you will get those codes. I would upgrade the firmware to the current level. You didn’t mention if you upgraded the firmware so I’m throwing it out as a possible solution.

    If at first you don’t succeed, redefine success


  6. 01-28-2013

    #6

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    30

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Thanks for the response. The firmware is up to date.
    The technician went to the m/c this morning and I will advise the outcome later this evening.
    Regards


  7. 01-29-2013

    #7

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    30

    Re: TASKalfa 500ci C7103,C7903 and C7904

    It looks like the machine has to come in to our service centre.
    The tech has exhausted all of the options at this point,rechecked connections etc.
    I will keep updating as it goes along.


  8. 01-29-2013

    #8

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Had you changed the developer and toner motors. There was an issue with these machine a few years ago and that was the solution. We change both sets as it is a pain to get to and change out.

    If at first you don’t succeed, redefine success


  9. 01-29-2013

    #9

    Re: TASKalfa 500ci C7103,C7903 and C7904

    I would look for pinched wires.


  10. 01-30-2013

    #10

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    30

    Re: TASKalfa 500ci C7103,C7903 and C7904

    The machine is now up and running. I first tried the original developer units and one drum unit. I kept getting c-codes 5101.7101.7102. and 7914. Since the original problem appeared to be this c-7914 I next removed the rear panels and removed the engine pcb and reinstalled the original engine board. Upon powering up the machine the machine got back to a ready state. I was able to generate all Maintenance Report information. As the firmware was able to install even during the time these c-code were occurring I will not do again. I do appreciate all of the input and views on my problem and hope that this may be of some help to others. I think I will make sure all of the developer units and drum units are in good shape before returning the machine to the customer and also print/copy a lot to make sure the machine is stable. Best Regards.


Tags for this Thread

Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

Японский производитель оргтехники Kyocera выпускает одни из самых качественных печатающих устройств на рынке, которые, в первую очередь, пользуются высоким спросом у бизнеса. А это уже говорит о многом!

На заметку! В отличие от частных покупателей, сильно подверженных рекламе и маркетинговым уловкам, большинство предпринимателей предпочитают вкладывать средства рационально.

Тем не менее, даже самая качественная оргтехника может давать сбои. Особенно, если за ней не следить!

Поэтому сегодня мы рассмотрим наиболее распространенные коды ошибок у популярных принтеров Kyocera FS-1020MFP, FS-1025MFP, FS-1030MFP, FS-1120MFP, FS-1125MFP, FS-1220MFP и прочих моделей, чтобы разобраться, какие неполадки можно устранить своими руками, а в каких случаях необходимо воспользоваться помощью специалистов.

  • Сброс ошибок у принтеров Kyocera своими руками
  • Устранение ошибок у принтеров Kyocera в сервисном центре

Под сбросом ошибок у принтеров Kyocera нужно понимать комплекс мероприятий, которые потенциально может осуществить опытный пользователь, чтобы восстановить работоспособность печатающих устройств без обращения в сервисный центр.

Ошибка №

Причина

Решение проблемы

E-0001

В принтере установлен совместимый картридж или чип расходника был поврежден. Проблема решается несколькими способами:

1. установка оригинального картриджа;

2. замена поврежденного чипа;

3. прошивка принтера – затем в печатающее устройство можно будет установить любой картридж неограниченное количество раз;

4. сброс ошибки – зажмите на несколько секунд кнопки «Режим» и «Сброс».

E-0002

Регион используемого картриджа не соответствует характеристикам принтера. Проблема решается несколькими способами:

1. установка соответствующего региону принтера картриджа;

2. замена чипа;

3. прошивка принтера.

E-0003

Память печатающего устройства заполнена. Распечатайте уже отсканированные документы или сбросьте операцию соответствующей кнопкой.

E-0007

В картридже закончился тонер. Замените картридж на новый оригинальный, совместимый или заправьте расходник.

E-0008

Одна из крышек принтера не закрыта. Захлопните заднюю и переднюю крышки принтера, ощутив характерный щелчок.

E-0009

Лоток с отпечатками переполнен. Извлеките распечатанные листы с бумагой, а затем возобновите печать кнопкой «Старт».

E-0012

Память принтера заполнена. Измените разрешение печати в меньшую сторону – до 600 dpi.

E-0014

Установлена бумага такого формата, который принтер не поддерживает. Замените бумагу листами совместимого формата.

Иногда функционал принтера может быть ограничен на софтверном уровне.

Чтобы расширить диапазон форматов, мы рекомендуем обновить ПО печатающего устройства.

E-0015

1. У принтера отсутствует питание.

2. Сетевой кабель не подключен.

3. На персональном компьютере отсутствует драйвер.

Проверьте целостность сетевого кабеля.

Включите принтер.

При необходимости установите драйвер.

E-0018

Выбранный файл отсутствует в очереди на печать. Сбросьте операцию, нажав на кнопку «Сброс». Затем выберите новый файл и продолжите печать.

E-0019

Формат печати не поддерживается принтером. Сбросьте операцию, нажав на кнопку «Сброс».

J-0511

Бумагу зажевало. Аккуратно извлеките остатки бумаги из корпуса принтера.

PF

Отсутствует бумага во входном лотке. Установите бумагу во входной лоток и возобновите печать, нажав на кнопку «Старт».

Устранение ошибок у принтеров Kyocera в сервисном центре

Ошибка №

Возможная причина

0030

Неисправна PWB-плата.

0100

Неисправна Flash-память или плата PWB.

0120

Неисправна Flash-память.

0190

Неисправна Flash-память или плата PWB.

0630

Неисправна PWB-плата.

2000

1. Неисправна PWB-плата;

2. неисправен соединительный кабель или нарушена целостность соединения контактов;

3. неисправен привод или его отдельные узлы.

3100

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. неисправен датчик положения;

3. неисправен привод сканера;

4. неисправна PWB-плата.

3300

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. неисправен датчик CIS;

3. неисправна PWB-плата.

3500

Неисправна PWB-плата.

4000

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. неисправен привод;

3. неисправна PWB-плата.

4200

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. неисправна PWB-плата и отдельные компоненты.

6000

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. неисправен термостат;

3. неисправен нагреватель фьюзера;

4. неисправна PWB-плата и отдельные компоненты.

6020

1. Неисправна PWB-плата и отдельные компоненты;

2. выявлен дефект у термистора.

6030

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. выявлен дефект у термистора;

3. неисправен термостат;

4. неисправна PWB-плата и отдельные компоненты.

6400

1. Неисправен соединительный кабель или нарушена целостность соединения контактов;

2. неисправна PWB-плата и отдельные компоненты.

F000

Неисправна PWB-плата и отдельные компоненты.

F020

Неисправна PWB-плата.

F040

Неисправна PWB-плата.

F05D

1. Неисправно программное обеспечение привода;

2. неисправна PWB-плата и отдельные компоненты.

Попытались самостоятельно устранить ошибку на принтере Kyocera, но проблемы с печатью остались нерешенными? Сервисный центр МосТонер – круглосуточный бесплатный выезд мастера в пределах МКАД. Вы платите только за результат!

2JZ/2JX/2JV/2H7-1

Code

C7912

Developing unit C EEPROM error

No response is issued from the device in

reading/writing for 5 ms or more and this

problem is repeated five times succes-

sively.

Mismatch of reading data from two loca-

tions occurs eight times successively.

Mismatch between writing data and

reading data occurs eight times succes-

sively.

C7913

Developing unit M EEPROM error

No response is issued from the device in

reading/writing for 5 ms or more and this

problem is repeated five times succes-

sively.

Mismatch of reading data from two loca-

tions occurs eight times successively.

Mismatch between writing data and

reading data occurs eight times succes-

sively.

C7914

Developing unit Y EEPROM error

No response is issued from the device in

reading/writing for 5 ms or more and this

problem is repeated five times succes-

sively.

Mismatch of reading data from two loca-

tions occurs eight times successively.

Mismatch between writing data and

reading data occurs eight times succes-

sively.

C7950

High voltage control PWB error

A communication error from high voltage

control PWB is detected 10 times in suc-

cession.

C8020

Punch motor problem (optional 3000-

sheet document finisher)

The error signal of the punch motor is

detected for more than 500 ms while the

punch motor is operating.

1-4-50

Contents

Causes

Check procedures/corrective measures

Poor contact in the

Check the connection of connector YC6 on

connector termi-

the sub front PWB and the continuity across

nals.

the connector terminals. Repair or replace if

necessary.

Defective develop-

Replace the developing unit C (see page 1-

ing PWB C.

5-34).

Poor contact in the

Check the connection of connector YC8 on

connector termi-

the sub front PWB and the continuity across

nals.

the connector terminals. Repair or replace if

necessary.

Defective develop-

Replace the developing unit M (see page 1-

ing PWB M.

5-34).

Poor contact in the

Check the connection of connector YC4 on

connector termi-

the sub front PWB and the continuity across

nals.

the connector terminals. Repair or replace if

necessary.

Defective develop-

Replace the developing unit Y (see page 1-

ing PWB Y.

5-34).

Poor contact in the

Check the connection of connector YC30 on

connector termi-

the engine PWB and the connector on the

nals.

high voltage control PWB, and the continuity

across the connector terminals. Repair or

replace if necessary.

Defective PWB.

Replace the high voltage control PWB or

engine PWB and check for correct opera-

tion.

Poor contact in the

Check the connection of connector on the

connector termi-

punch PWB and the continuity across the

nals.

connector terminals. Repair or replace if

necessary.

Defective punch

Replace the punch motor.

motor.

Defective PWB.

Replace the punch PWB or finisher main

PWB and check for correct operation.

Remarks

Likes Likes:  0

Dislikes Dislikes:  0

  1. 01-27-2013


    #1

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    TASKalfa 500ci C7103,C7903 and C7904

    The inital call resulted in a copy quality issue and the fuser and transfer belt were replaced.
    Later a C7103 toner snsor M so drum and developer were replaced. No joy there.
    Next the sub front and main front pcb were changed followed by the Engine pcb.
    Now the code is a C904 yellow drum eprom.
    The components changed as mentioned above were reinstalled in another machine and work fine.
    I think the next step will be changing all developers and drums to see if the machine comes to a ready state.

    Any thoughts or suggestions would be appreciated.
    Thanks in advance and I will post the final resolution to the problem.


  2. 01-27-2013


    #2

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Quote Originally Posted by EDSNOW
    View Post

    The inital call resulted in a copy quality issue and the fuser and transfer belt were replaced.
    Later a C7103 toner snsor M so drum and developer were replaced. No joy there.
    Next the sub front and main front pcb were changed followed by the Engine pcb.
    Now the code is a C904 yellow drum eprom.
    The components changed as mentioned above were reinstalled in another machine and work fine.
    I think the next step will be changing all developers and drums to see if the machine comes to a ready state.

    Any thoughts or suggestions would be appreciated.
    Thanks in advance and I will post the final resolution to the problem.

    I’m assuming two things:
    1) C904 is really C7904
    2) you’ve re-seated all the connectors on the sub front and main front PWBs. Were these parts new or scavenged? Are the connector pins intact (not bent or slipping out of the connector)?

    If these parts were new, then yes try the yellow drum. Are there any other errors recorded?
    I wouldn’t have done anything differently. =^..^=

    If you’d like a serious answer to your request:
    1) demonstrate that you’ve read the manual
    2) demonstrate that you made some attempt to fix it.
    3) if you’re going to ask about jams include the jam code.
    4) if you’re going to ask about an error code include the error code.
    5) You are the person onsite. Only you can make observations.

    blackcat: Master Of The Obvious =^..^=


  3. 01-27-2013


    #3

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Hi Blackcat
    The main and subboards were from our 400ci at the office.
    The boards from the down machine were reinstalled in our unit and work fine.
    I do appreciate your quick response and the new c-7904 yellow drum eprom is what is showing at the moment.
    The tech spent most od Friday at this site.
    Thanks


  4. 01-27-2013


    #4

    Lightbulb Re: TASKalfa 500ci C7103,C7903 and C7904

    This Parts & Service Manual can now be purchased for $12.77 and downloaded immediately after payment from:

    Just Manuals, The Internet’s largest selection of manuals ~ Instant Downloads

    Paul@justmanuals.com


  5. 01-28-2013


    #5

    Re: TASKalfa 500ci C7103,C7903 and C7904

    The new developers will not operate with older firmware, you will get those codes. I would upgrade the firmware to the current level. You didn’t mention if you upgraded the firmware so I’m throwing it out as a possible solution.

    If at first you don’t succeed, redefine success


  6. 01-28-2013


    #6

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Thanks for the response. The firmware is up to date.
    The technician went to the m/c this morning and I will advise the outcome later this evening.
    Regards


  7. 01-29-2013


    #7

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Re: TASKalfa 500ci C7103,C7903 and C7904

    It looks like the machine has to come in to our service centre.
    The tech has exhausted all of the options at this point,rechecked connections etc.
    I will keep updating as it goes along.


  8. 01-29-2013


    #8

    Re: TASKalfa 500ci C7103,C7903 and C7904

    Had you changed the developer and toner motors. There was an issue with these machine a few years ago and that was the solution. We change both sets as it is a pain to get to and change out.

    If at first you don’t succeed, redefine success


  9. 01-29-2013


    #9

    Re: TASKalfa 500ci C7103,C7903 and C7904

    I would look for pinched wires.


  10. 01-30-2013


    #10

    EDSNOW is offline


    Senior Tech

    100+ Posts


    Rep Power
    31

    Re: TASKalfa 500ci C7103,C7903 and C7904

    The machine is now up and running. I first tried the original developer units and one drum unit. I kept getting c-codes 5101.7101.7102. and 7914. Since the original problem appeared to be this c-7914 I next removed the rear panels and removed the engine pcb and reinstalled the original engine board. Upon powering up the machine the machine got back to a ready state. I was able to generate all Maintenance Report information. As the firmware was able to install even during the time these c-code were occurring I will not do again. I do appreciate all of the input and views on my problem and hope that this may be of some help to others. I think I will make sure all of the developer units and drum units are in good shape before returning the machine to the customer and also print/copy a lot to make sure the machine is stable. Best Regards.


Tags for this Thread

Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

Понравилась статья? Поделить с друзьями:

Интересное по теме:

  • Kyocera ошибка c6250
  • Kyocera ошибка 7902
  • Kyocera ошибка c7412
  • Kyocera ошибка 7001
  • Kyocera ошибка 600

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии