  1. 09-28-2012


    #1

    Error C:0150 on FS9530DN

    I have a high volume FS9530DN giving C:0150 EPROM error codes and have flashed via USB several times. It will work for 10 to 15 minutes then stop, paper is always jammed coming out of the fuser. I repalced the fuser as well to eliminate that. This printer is in a critical print area, any help is appreciated!


  2. 09-28-2012


    #2

    Re: Error C:0150 on FS9530DN

    Have you tried updating the firmware with a Compact Flashcard, instead of USB?

    Do for one what you wished you could do for everyone. — Andy Stanley


  3. 10-01-2012


    #3

    Re: Error C:0150 on FS9530DN

    No, does it make a difference how the flash is performed? I have 4 of these in one location, hooked directly to inserters, and 3 of them have exhibited the C0150 error codes, however only this one continues to show this code after flashing from USB.


  4. 10-01-2012


    #4

    Re: Error C:0150 on FS9530DN

    Sometimes Flashing does correct the problem. Sometimes, not so lucky. I’ve got a FS-4020DN that is doing almost the same thing. Flashed using USB and Compact Flash Card .
    Re-flash FW make two or three prints…0150 code. Repeat , Repeat , …

    Have an EEPROM on order to try next. Hopefully this will correct the problem without changing the Engine Board.

    Like DWISE suggested…try up-dating the firmware using a compact flash Card.

    Good Luck ……. Please keep us up-dated on this ……………

    «The Serenity Prayer» . . .
    God grant me the serenity to accept stupid people , the courage to not waste my time and energy on them , and the wisdom to know that I cannot fix STUPID .


  5. 10-02-2012


    #5

    Re: Error C:0150 on FS9530DN

    I replaced the engine board yesterday with no change in performance. I have looked in the parts manual for the EEPROM part # but did not find it listed anywhere.


  6. 10-02-2012


    #6

    Re: Error C:0150 on FS9530DN

    You will need to call the Helpdesk…tell them what is going on, and get the part number from them.

    Good Luck ….. I’m still waiting on the EEPROM I ordered .

    «The Serenity Prayer» . . .
    God grant me the serenity to accept stupid people , the courage to not waste my time and energy on them , and the wisdom to know that I cannot fix STUPID .


  7. 10-05-2012


    #7

    Re: Error C:0150 on FS9530DN

    OK, I flashed with CF Card with no change. I have ordered EPROM. Today, the other three 9530’s all go down with the C0150 error, two reset by customer, one still down. I am very concerned that there is a problem with this engine from Kyocera. My customer does around 100K per week on the 4 units and of course are concerned about the product and/or our ability to identify and correct the problem.


  8. 10-07-2012


    #8

    madas is offline


    Senior Tech

    250+ Posts

    madas's Avatar


    Rep Power
    34

    Re: Error C:0150 on FS9530DN

    Hi.
    I had an FS-2000 which had the same error, I changed the EEPROM and that fixed the fault so hopefully you will have the same result.
    This was posted to give you a glimmer of hope on a Monday Morning lol, good luck.

    madas

    PS we had a FS-C2126 with the same fault, please note you cannot change the EEPROM on these m/c’s we had to swap the m/c out.


  9. 10-08-2012


    #9

    Re: Error C:0150 on FS9530DN

    I had the same code on a 9530. Call tech support for an epom. Put it in, call tech support and they will put the s.n. and meter count in.


  10. 10-08-2012


    #10

    Re: Error C:0150 on FS9530DN

    Quote Originally Posted by Tonerkiller
    View Post

    I had the same code on a 9530. Call tech support for an epom. Put it in, call tech support and they will put the s.n. and meter count in.

    TonerKiller is right ……… If the firmware ( oops, I meant frimwar ) does not correct the problem….gotta do the new EEPROM and ‘ Help Desk ‘ link up.
    Usually the update does the trick … since I put in the new EEPROM the 4020 runs fine now … just no page count or Serial Number . I will have to get the ‘ Help Desk ‘ in on this one. I wonder if this ( 4020 ) did not just reload count and S/N because it is Wise Core ?

    «The Serenity Prayer» . . .
    God grant me the serenity to accept stupid people , the courage to not waste my time and energy on them , and the wisdom to know that I cannot fix STUPID .


Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules


Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.

В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.

Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.

Код ошибки Описание ошибки Причина ошибки
0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem.
Defective FAX control PWB.
0060 Engine PWB type error Defective engine sub PCB.
0070 FAX control PWB incompatible detection error
Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted.
Defective FAX software
Defective FAX control PWB.
0100 Backup memory device error Defective flash memory.
0120 MAC address data error
For data in which the MAC address is invalid.
Defective main PWB.
Defective flash memory.
Defective engine PWB.
0130 Backup memory read/write error (main PWB) Defective flash memory.
Defective main PWB.
0140 Backup memory data error (main PWB) Defective flash memory.
Defective main PWB.
0150 Backup memory read/write error (engine PWB)
Detecting engine PWB EEPROM communication error.
Improper installation engine PWB EEPROM.
Defective engine PWB.
Device damage of EEPROM.
0160 Backup memory data error (engine PWB) Defective flash memory.
Defective engine PWB.
0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters.
Data damage of EEPROM.
Defective PWB.
0180 Machine number mismatch
Machine number of main and engine does not match.
Data damage of EEPROM.
0320 I/O CPU communication error
A communication error is detected 10 times in succession.
Defective PWB.
0630 DMA error DMA transmission of image data does not complete within the specified period of time. Poor contact in the connector terminals. Defective main PWB.
0800 Image processing error
JAM05 is detected twice.
Defective main PWB.
0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB.
Defective FAX software.
Defective FAX control PWB.
0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
The battery is disconnected from the main PWB.
Defective main PWB.
0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
Improper installation FAX control PWB.
Defective FAX control PWB or main PWB.
0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB.
Defective FAX control PWB.
1010 Lift motor error
After cassette 1 is inserted, lift sensor does not turn on within 12 s. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette.
Defective connector cable or poor contact in the connector.
Defective drive transmission system of the lift motor.
Defective lift motor.
Defective engine PWB.
1020 PF lift motor error (paper feeder)
After cassette 2 is inserted, PF lift sensor 1 does not turn on within 12 s. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette.
Defective connector cable or poor contact in the connector.
Defective drive transmission system of the PF lift motor 1.
Defective PF lift motor 1.
Defective PF main PWB.
1030 PF lift motor error (paper feeder)
After cassette 3 is inserted, PF lift sensor 2 does not turn on within 12 s. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette.
Defective connector cable or poor contact in the connector.
Defective drive transmission system of the PF lift motor 2.
Defective PF lift motor 2.
Defective PF main PWB.
1800 Paper feeder communication error
A communication error is detected 10 times in succession.
Improper installation paper feeder.
Defective connector cable or poor contact in the connector.
Defective engine PWB.
Defective PF main PWB.
1900 Paper feeder EEPROM error
When writing the data, the write data and the read data is not continuously in agreement 5 times.
Defective PF main PWB.
Device damage of EEPROM.
2000 Main motor steady-state error
Stable OFF is detected for 1 s continuously after main motor stabilized.
Defective connector cable or poor contact in the connector.
Defective drive transmission system of the main motor.
Defective main motor.
Defective engine PWB.
2010 Main motor drive error
The main motor is not stabilized within 2 s after driving starts.
Defective connector cable or poor contact in the connector.
Defective drive transmission system of the main motor.
Defective main motor.
Defective engine PWB.
2600 PF drive motor error (paper feeder)
When the PF drive motor is driven, error signal is detected continuously for 1 s.
Defective connector cable or poor contact in the connector.
Defective drive transmission system of the PF drive motor.
Defective PF drive motor.
Defective PF main PWB.
3100 ISU home position error
The home position is not correct when the power is turned on or at the start of copying using the table.
Defective connector cable or poor contact in the connector.
Defective home position sensor.
Defective ISU motor.
Defective CCD PWB.
Defective engine PWB.
3200 Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
Defective connector cable or poor contact in the connector.
Defective exposure lamp.
Defective CCD PWB.
Defective main PWB.
3500 Communication error between scanner and ASIC
An error code is detected 3 times in succession.
Defective connector cable or poor contact in the connector.
Defective CCD PWB.
Defective main PWB.
3600 Scanner sequence error Defective main PWB or engine PWB.
4000 Polygon motor synchronization error
The polygon motor is not stabilized within 10 s after driving starts.
Defective connector cable or poor contact in the connector.
Defective polygon motor.
Defective engine PWB.
4010 Polygon motor steady-state error
Stable OFF is detected for 1 s continuously after polygon motor stabilized.
Defective connector cable or poor contact in the connector.
Defective polygon motor.
Defective engine PWB.
4100 BD initialization error
BD is not detected within 1 s after polygon motor stabilized.
Defective connector cable or poor contact in the connector.
Defective APC PWB.
Defective BD PWB.
Defective main PWB.
4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector.
Defective main PWB or engine PWB.
6000 Broken fuser heater wire
The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The fusing temperature at 7 seconds and 20 seconds since fuser temperature control has occurred differs by 43°C/109.4°F or less.
Defective connector cable or poor contact in the connector.
Deformed connector pin.
Defective triac.
Fuser thermostat triggered.
Broken fuser heater wire.
Defective engine PWB.
6000
6020
6030
6050
Broken fuser heater wire
Abnormally high fuser thermistor temperature Broken fuser thermistor wire Abnormally low fuser thermistor temperature
Deformed connector pin.
Defective triac.
6020 Abnormally high fuser thermistor temperature
The fuser thermistor detects a temperature higher than 230°C/446°F continuously for 40 ms. High fuser temperature signal detects a temperature of 255°C/491°F continuously for 40 ms.
Deformed connector pin.
Defective triac.
Shorted fuser thermistor.
Defective engine PWB.
6030 Broken fuser thermistor wire
A/D value of the fuser thermistor exceeds 251 bit continuously for 7 s during warming up.
Defective connector cable or poor contact in the connector.
Deformed connector pin.
Defective triac.
Defective fuser thermistor.
Defective engine PWB
6050 Abnormally low fuser thermistor temperature
As the stable temperature has reached the second time, the decrease in the fuser thermistor temperature of 60°C/140°F or greater is detected for one second.
Deformed connector pin.
Defective triac.
Defective fuser thermistor
Defective fuser heater.
Defective engine PWB.
6400 Zero-cross signal error
While fuser heater control is performed, the zero-cross signal is not input within 3 s.
Defective connector cable or poor contact in the connector
Defective power source PWB or engine PWB.
7800 Broken external thermistor wire
The thermistor output value is 0.3 V or less.
Defective connector cable or poor contact in the connector.
Defective temperature sensor.
7810 Short-circuited external thermistor wire
The thermistor output value is 3 V or more.
Defective connector cable or poor contact in the connector.
Defective temperature sensor.
7900 Drum unit EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Defective connector cable or poor contact in the connector.
Defective drum unit.
7910 Developer unit EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Defective connector cable or poor contact in the connector.
Defective developer unit.
8030 Tray upper limit detection problem (document finisher)
When the tray elevation motor raises a tray, the ON status of the tray upper limit sensor is detected.
Defective connector cable or poor contact in the connector.
Defective tray upper limit sensor, paper surface sensor 1/2.
Defective DF main PWB.
8040 Belt problem (document finisher)
The belt sensor does not turn on/off within specified time of the belt solenoid turning on.
Defective connector cable or poor contact in the connector.
Defective belt sensor.
Defective belt solenoid.
Defective DF main PWB.
8140 Tray elevation motor problem (document finisher)
The tray low limit sensor or paper surface sensor 1/2 cannot be detected to be on within 10 s since the tray elevation motor is activated.
Defective connector cable or poor contact in the connector.
Defective connector cable or poor contact in the connector.
The tray elevation motor malfunctions.
Defective tray lower limit sensor, paper surface sensor 1/2.
Defective DF main PWB.
8210 Stapler problem (document finisher)
Jam 7012 or 7023 is indicated.
Defective connector cable of staple or poor contact in the connector.
The stapler is blocked with a staple.
The stapler is broken
Defective DF main PWB.
8320 Adjustment motor 2 problem (document finisher)
The adjustment sensor 2 does not turn on/off within specified time of the adjustment motor 2 turning on.
Defective connector cable or poor contact in the connector.
Defective adjustment sensor 2.
Defective adjustment motor 2.
Defective DF main PWB.
8330 Adjustment motor 1 problem (document finisher)
The adjustment sensor 1 does not turn on/off within specified time of the adjustment motor 1 turning on.
Defective connector cable or poor contact in the connector.
Defective adjustment sensor 1.
Defective adjustment motor 1.
8350 Roller motor problem (document finisher)
The roller sensor does not turn on/off within specified time of the roller motor turning on.
Defective DF main PWB.
Defective connector cable or poor contact in the connector.
Defective roller sensor.
Defective roller motor.
Defective DF main PWB.
8360 Slide motor problem (document finisher)
The slide sensor does not turn on/off within specified time of the slide motor turning on.
Defective connector cable or poor contact in the connector.
Defective slide sensor.
Defective slide motor.
Defective DF main PWB.
8460 EEPROM problem (document finisher)
Reading from or writing to EEPROM cannot be performed.
Defective EEPROM or DF main PWB.
8800 Document finisher communication error
A communication error is detected 10 times in succession.
Defective connector cable or poor contact in the connector
Defective DF main PWB.
Defective engine PWB.
8830 Bridge communication error (document finisher)
A communication error is detected 10 times in succession.
Defective connector cable or poor contact in the connector.
Defective bridge PWB.
Defective engine PWB.
8990 Document finisher communication error Defective connector cable or poor contact in the connector.
Defective DF main PWB.
Defective bridge PWB.
9000 Document processor communication error
A communication error is detected 10 times in succession.
Defective connector cable or poor contact in the connector.
Defective DP main PWB.
9060 DP EEPROM error Read and write data does not match. Data in the specified area of the backup memory does not match the specified values. Defective DP main PWB.
Device damage of EEPROM.
9500 BRU communication error IPU PWB error
9510 BRU PWB error IPU PWB error
9520 BRU PWB data error IPU PWB error
F000 Main PWB — operation panel PWB communication error Defective main PWB.
Defective operation panel PWB.
F010 Main PWB checksum error Defective main PWB.
F040 Main PWB — print engine communication error Defective main PWB.
Defective engine PWB.
F050 Print engine ROM checksum error Defective engine PWB.

Ошибки Kyocera ECOSYS M2030dn

Ошибки Kyocera ECOSYS M2030pn

Ошибки Kyocera ECOSYS M2035dn

Ошибки Kyocera ECOSYS M2040dn

Ошибки Kyocera ECOSYS M2135dn

Ошибки Kyocera ECOSYS M2530dn

Ошибки Kyocera ECOSYS M2535dn

Ошибки Kyocera ECOSYS M2540dn

Ошибки Kyocera ECOSYS M2540dw

Ошибки Kyocera ECOSYS M2635dn

Ошибки Kyocera ECOSYS M2635dw

Ошибки Kyocera ECOSYS M2640idw

Ошибки Kyocera ECOSYS M3040dn

Ошибки Kyocera ECOSYS M3040idn

Ошибки Kyocera ECOSYS M3145dn

Ошибки Kyocera ECOSYS M3145idn

Ошибки Kyocera ECOSYS M2735dw

Ошибки Kyocera ECOSYS M3540dn

Ошибки Kyocera ECOSYS M3540idn

Ошибки Kyocera ECOSYS M3550idn

Ошибки Kyocera ECOSYS M3560idn

Ошибки Kyocera ECOSYS M3645dn

Ошибки Kyocera ECOSYS M3645idn

Ошибки Kyocera ECOSYS M3655idn

Ошибки Kyocera ECOSYS M3660idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M4125idn

Ошибки Kyocera ECOSYS M4132idn

Ошибки Kyocera ECOSYS M5521cdn

Ошибки Kyocera ECOSYS M5521cdw

Ошибки Kyocera ECOSYS M5526cdn

Ошибки Kyocera ECOSYS M5526cdw

Ошибки Kyocera ECOSYS M6026cdn

Ошибки Kyocera ECOSYS M6026cidn

Ошибки Kyocera ECOSYS M6030cdn

Ошибки Kyocera ECOSYS M6035cidn

Ошибки Kyocera ECOSYS M6230cidn

Ошибки Kyocera ECOSYS M6235cidn

Ошибки Kyocera ECOSYS M6526cdn

Ошибки Kyocera ECOSYS M6526cidn

Ошибки Kyocera ECOSYS M6530cdn

Ошибки Kyocera ECOSYS M6535cidn

Ошибки Kyocera ECOSYS M6630cidn

Ошибки Kyocera ECOSYS M6635cidn

Ошибки Kyocera ECOSYS M8124cidn

Ошибки Kyocera ECOSYS M8130cidn

Ошибки Kyocera ECOSYS P2035d

Ошибки Kyocera ECOSYS P2040dn

Ошибки Kyocera ECOSYS P2040dw

Ошибки Kyocera ECOSYS P2135d

Ошибки Kyocera ECOSYS P2135dn

Ошибки Kyocera ECOSYS P2235dn

Ошибки Kyocera ECOSYS P2235dw

Ошибки Kyocera ECOSYS P3045dn

Ошибки Kyocera ECOSYS P3050dn

Ошибки Kyocera ECOSYS P3055dn

Ошибки Kyocera ECOSYS P3060dn

Ошибки Kyocera ECOSYS P3145dn

Ошибки Kyocera ECOSYS P3150dn

Ошибки Kyocera ECOSYS P3155dn

Ошибки Kyocera ECOSYS P3160dn

Ошибки Kyocera ECOSYS P3260dn

Ошибки Kyocera ECOSYS P4035dn

Ошибки Kyocera ECOSYS P4040dn

Ошибки Kyocera ECOSYS P5021cdn

Ошибки Kyocera ECOSYS P5021cdw

Ошибки Kyocera ECOSYS P5026cdn

Ошибки Kyocera ECOSYS P5026cdw

Ошибки Kyocera ECOSYS P6021cdn

Ошибки Kyocera ECOSYS P6026cdn

Ошибки Kyocera ECOSYS P6030cdn

Ошибки Kyocera ECOSYS P6035cdn

Ошибки Kyocera ECOSYS P6130cdn

Ошибки Kyocera ECOSYS P6230cdn

Ошибки Kyocera ECOSYS P6235cdn

Ошибки Kyocera ECOSYS P7035cdn

Ошибки Kyocera ECOSYS P7040cdn

Ошибки Kyocera ECOSYS P7240cdn

Ошибки Kyocera ECOSYS P8060cdn

Ошибки Kyocera FS-C8600DN

Ошибки Kyocera FS-C8650DN

Ошибки Kyocera FS1016MFP

Ошибки Kyocera FS1018MFP

Ошибки Kyocera FS1020MFP

Ошибки Kyocera FS1024MFP

Ошибки Kyocera FS1025MFP

Ошибки Kyocera FS1028MFP

Ошибки Kyocera FS1030MFP

Ошибки Kyocera FS1035MFP

Ошибки Kyocera FS1040

Ошибки Kyocera FS1050

Ошибки Kyocera FS1060DN

Ошибки Kyocera FS1100

Ошибки Kyocera FS1110

Ошибки Kyocera FS1116MFP

Ошибки Kyocera FS1118MFP

Ошибки Kyocera FS1120

Ошибки Kyocera FS1120MFP

Ошибки Kyocera FS1124MFP

Ошибки Kyocera FS1125MFP

Ошибки Kyocera FS1128MFP

Ошибки Kyocera FS1130MFP

Ошибки Kyocera FS1135MFP

Ошибки Kyocera FS1200

Ошибки Kyocera FS1220MFP

Ошибки Kyocera FS1300D

Ошибки Kyocera FS1320D

Ошибки Kyocera FS1320MFP

Ошибки Kyocera FS1325MFP

Ошибки Kyocera FS1350DN

Ошибки Kyocera FS1370DN

Ошибки Kyocera FS1500

Ошибки Kyocera FS6020

Ошибки Kyocera FS6025MFP

Ошибки Kyocera FS6025MFPB

Ошибки Kyocera FS6030MFP

Ошибки Kyocera FS6500

Ошибки Kyocera FS6525MFP

Ошибки Kyocera FS6530MFP

Ошибки Kyocera FS6700

Ошибки Kyocera FS6900

Ошибки Kyocera FS6950DN

Ошибки Kyocera FS8000CD

Ошибки Kyocera FS8000CN

Ошибки Kyocera FS8100DN

Ошибки Kyocera TASKalfa 180

Ошибки Kyocera TASKalfa 1800

Ошибки Kyocera TASKalfa 1801

Ошибки Kyocera TASKalfa 181

Ошибки Kyocera TASKalfa 205c

Ошибки Kyocera TASKalfa 220

Ошибки Kyocera TASKalfa 2200

Ошибки Kyocera TASKalfa 2201

Ошибки Kyocera TASKalfa 221

Ошибки Kyocera TASKalfa 2420w

Ошибки Kyocera TASKalfa 2460ci

Ошибки Kyocera TASKalfa 2470ci

Ошибки Kyocera TASKalfa 250ci

Ошибки Kyocera TASKalfa 2510i

Ошибки Kyocera TASKalfa 2520i

Ошибки Kyocera TASKalfa 255

Ошибки Kyocera TASKalfa 2550ci

Ошибки Kyocera TASKalfa 2551ci

Ошибки Kyocera TASKalfa 2552ci

Ошибки Kyocera TASKalfa 2553ci

Ошибки Kyocera TASKalfa 255b

Ошибки Kyocera TASKalfa 255c

Ошибки Kyocera TASKalfa 265ci

Ошибки Kyocera TASKalfa 300ci

Ошибки Kyocera TASKalfa 300i

Ошибки Kyocera TASKalfa 3010i

Ошибки Kyocera TASKalfa 3011i

Ошибки Kyocera TASKalfa 305

Ошибки Kyocera TASKalfa 3050ci

Ошибки Kyocera TASKalfa 3051ci

Ошибки Kyocera TASKalfa 306ci

Ошибки Kyocera TASKalfa 307ci

Ошибки Kyocera TASKalfa 308ci

Ошибки Kyocera TASKalfa 3212i

Ошибки Kyocera TASKalfa 3252ci

Ошибки Kyocera TASKalfa 3253ci

Ошибки Kyocera TASKalfa 3500i

Ошибки Kyocera TASKalfa 3501i

Ошибки Kyocera TASKalfa 350ci

Ошибки Kyocera TASKalfa 3510i

Ошибки Kyocera TASKalfa 3511i

Ошибки Kyocera TASKalfa 3550ci

Ошибки Kyocera TASKalfa 3551ci

Ошибки Kyocera TASKalfa 3552ci

Ошибки Kyocera TASKalfa 3553ci

Ошибки Kyocera TASKalfa 356ci

Ошибки Kyocera TASKalfa 358ci

Ошибки Kyocera TASKalfa 4002i

Ошибки Kyocera TASKalfa 4003i

Ошибки Kyocera TASKalfa 400ci

Ошибки Kyocera TASKalfa 4012i

Ошибки Kyocera TASKalfa 4052ci

Ошибки Kyocera TASKalfa 4053ci

Ошибки Kyocera TASKalfa 406ci

Ошибки Kyocera TASKalfa 408ci

Ошибки Kyocera TASKalfa 420i

Ошибки Kyocera TASKalfa 4500i

Ошибки Kyocera TASKalfa 4501i

Ошибки Kyocera TASKalfa 4550ci

Ошибки Kyocera TASKalfa 4551ci

Ошибки Kyocera TASKalfa 4820w

Ошибки Kyocera TASKalfa 5002i

Ошибки Kyocera TASKalfa 5003i

Ошибки Kyocera TASKalfa 500ci

Ошибки Kyocera TASKalfa 5052ci

Ошибки Kyocera TASKalfa 5053ci

Ошибки Kyocera TASKalfa 508ci

Ошибки Kyocera TASKalfa 520i

Ошибки Kyocera TASKalfa 5500i

Ошибки Kyocera TASKalfa 5501i

Ошибки Kyocera TASKalfa 550c

Ошибки Kyocera TASKalfa 552ci

Ошибки Kyocera TASKalfa 5550ci

Ошибки Kyocera TASKalfa 5551ci

Ошибки Kyocera TASKalfa 6002i

Ошибки Kyocera TASKalfa 6003i

Ошибки Kyocera TASKalfa 6052ci

Ошибки Kyocera TASKalfa 6053ci

Ошибки Kyocera TASKalfa 620

Ошибки Kyocera TASKalfa 6500i

Ошибки Kyocera TASKalfa 6501i

Ошибки Kyocera TASKalfa 650c

Ошибки Kyocera TASKalfa 6550ci

Ошибки Kyocera TASKalfa 6551ci

Ошибки Kyocera TASKalfa 7002i

Ошибки Kyocera TASKalfa 7003i

Ошибки Kyocera TASKalfa 7052ci

Ошибки Kyocera TASKalfa 7353ci

Ошибки Kyocera TASKalfa 750c

Ошибки Kyocera TASKalfa 7550ci

Ошибки Kyocera TASKalfa 7551ci

Ошибки Kyocera TASKalfa 8000i

Ошибки Kyocera TASKalfa 8001i

Ошибки Kyocera TASKalfa 8002i

Ошибки Kyocera TASKalfa 8003i

Ошибки Kyocera TASKalfa 8052ci

Ошибки Kyocera TASKalfa 820

Ошибки Kyocera TASKalfa 8353ci

Ошибки Kyocera TASKalfa 9002i

Ошибки Kyocera TASKalfa 9003i

Оборудование оснащено функцией самодиагностики. При обнаружении проблемы, аппарат блокируется, на дисплее отображается код вида С#### с указанием характера проблемы. Также появляется сообщение необходимости обслуживания. После устранения проблемы, ошибку можно сбросить тумблером питания, выключив и включив аппарат.

Код
Значение
Описание
Причина
Решение




C0030 FAX control PWB system error Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB.
Replace the FAX control PWB
C0070 FAX control PWB incompatible detection Error Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. Defective fax software. Defective FAX control PWB.
Install the fax software. Replace the FAX control PWB
C0100 Backup memory device error
Defective flash memory. Defective control PWB.
Replace the control PWB
C0120 MAC address data error
Defective flash memory.
Replace the control PWB
C0130 Backup memory read/write error
Defective flash memory. Defective control PWB
Replace the control PWB
C0140 Backup memory data error
Defective flash memory. Defective control PWB.
Replace the control PWB
C0150 Control PWB EEPROM error Detecting control PWB EEPROM (U17) communication error. Improper installation control PWB EEPROM (U17). Defective control PWB. Data damage of control PWB EEPROM (U17).
Check the installation of the EEPROM (U17) and remedy if necessary. Replace the control PWB.
C0170 Billing counting error
Defective control PWB. Data damage of control PWB EEPROM (U17).
Replace the control PWB
C0180 Machine number mismatch Machine number of main and engine does not match. The main PWB or the engine PWB were exchanged. Data damage of control PWB EEPROM (U17).
U004 Setting the machine number.
C0420 Paper feeder communication error Communication error between control PWB and optional paper feeder. Improper installation paper feeder. Defective harness between control PWB (YC30) and paper feeder interface connector, or improper connector insertion. Defective control PWB. Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. Defective PF mainPWB.
Follow installation instruction carefully again. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Replace the control PWB. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). Replace the PF main PWB (Refer to the service manual for the paper feeder).
C0830 FAX control PWB flash program area checksum error A checksum error occurred with the program of the FAX control PWB. Defective fax software. Defective FAX control PWB.
Install the fax software. Replace the FAX control PWB
C0840 Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. Defective control PWB. The battery is disconnected from the control PWB.
Replace the control PWB. Check visually and remedy if necessary.
C0870 FAX control PWB to control PWB high capacity data transfer problem High-capacity data transfer between the FAX control PWB and the control PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB. Defective FAX control PWB or control PWB.
Reinstall the FAX control PWB. Replace the FAX control PWB or control PWB and check for correct operation.
C0920 Fax file system error The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB.
Replace the FAX control PWB.
C2000 Main motor error The main motor ready input is not given for 2 s during the main motor is ON. Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion. Defective drive transmission system of the main motor. Defective main motor. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Replace the main motor. Replace the control PWB.
C2610 PF paper feed motor error (paper feeder) The PF paper feed motor of cassette 2 ready input is not given for 2 s during the PF paper feed motor is ON. Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Defective PF paper feed motor drive transmission system. Defective PF main motor. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Replace the PF main motor. Replace the control PWB.
C2620 PF paper feed motor error (Paper feeder) The PF paper feed motor of cassette 3 ready input is not given for 2 s during the PF paper feed motor is ON. Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Defective PF paper feed motor drive transmission system. Defective PF main motor. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder). Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Replace the PF main motor (Refer to the service manual for the paper feeder). Replace the control PWB.
C3100 ISU home position errorr.
Defective FFC between CCD PWB (YC1) and control PWB (YC8). Defective FFC between control PWB (YC6) and scanner PWB (YC103), or improper FFC insertion. Defective home position sensor. Defective harness between ISU motor and scanner PWB (YC104), or improper connector insertion. Defective ISU motor.
Replace the image scanner unit (ISU). Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC. Replace the home position sensor. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Replace the ISU motor.
C3200 Exposure lamp error The exposure lamp is not turned on. Defective FFC between scanner PWB (YC103) and control PWB (YC6), or improper FFC insertion. Defective FFC between CCD PWB (YC1) and control PWB (YC8). Defective harness between CCD PWB (YC3) and LED drive PWB (YC1), or improper connector insertion. Defective harness between LED drive PWB (YC2) and exposure lamp, or improper connector insertion. Defective exposure lamp.sensor. Defective LED drive PWB. Defective control PWB.
Reinsert the FFC. Also check for continuity within the FFC. If none, remedy or replace the FFC. Replace the image scanner unit (ISU). Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Replace the exposure lamp. Replace the LED drive PWB. Replace the control PWB.
C3300 AGC error After AGC, correct input is not obtained at CCD. Defective FFC between CCD PWB (YC1) and control PWB (YC8). Defective exposure lamp.sensor. Defective CCD PWB. Defective control PWB.
Replace the image scanner unit (ISU). Replace the exposure lamp. Replace the CCD PWB. Replace the control PWB.
C3500 CPU — ASIC (CCD PWB) communication error An error code is detected. Defective FFC between CCD PWB (YC1) and control PWB (YC8). Defective CCD PWB. Defective control PWB.
Replace the image scanner unit (ISU). Replace the CCD PWB. Replace the control PWB.
C4000 Polygon motor (laser scanner unit) error The polygon motor ready input is not given for 6 s during the polygon motor is ON. Defective harness between polygon motor and control PWB (YC10), or improper connector insertion. Defective laser scanner unit. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector har- ness. If none, remedy or replace the harness. Replace the laser scanner unit. Replace the control PWB.
C4200 BD error (laser scanner unit) error
BD sensor does not detect laser beam due to condensation on the polygon mirror. Defective laser scanner unit. Defective control PWB.
Turn machine power off for at least 30 minutes, then turn machine on again. If not cured, replace the laser scanner unit. Replace the control PWB.
C4700 VIDEO ASIC device error Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Replace the control PWB.
C6000 Broken Fuser heater wire The fuser temperature does not rise after the Fuser heater has been turned on. Poor contact in the fuser thermistor connector terminals. Poor contact in the Fuser heater connector terminals. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater installed incorrectly. Broken Fuser heater wire.
Reinsert the connector. Replace the fuser unit.
C6020 Abnormally high fuser thermistor temperature Fuser thermistor detects abnormally temperature. When the temperature of a fuser thermistor detects 195 °C or more at the time of heater OFF and 155 °C or more. Shorted fuser thermistor. Defective control PWB.
Replace the fuser unit. Replace the control PWB.
C6030 Broken fuser thermistor wire Input from fuser thermistor is 0 (A/D value). Poor contact in the fuser thermistor connector terminals. Broken fuser thermistor wire. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater installed incorrectly. Broken Fuser heater wire.
Reinsert the connector. Replace the fuser unit.
C6400 Zero cross signal error The zero cross signal does not reach the control PWB for specified time. Defective harness between high voltage PWB (CN202) and control PWB (YC23), or improper connector insertion. Defective connection between power source PWB (YC103) and high voltage PWB (CN201). Defective power source PWB. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Reinsert the connector. Replace the power source PWB. Replace the control PWB.
C7990 Waste toner full The waste toner sensor has detected that the waste toner reservoir (drum unit) is full. Waste toner reservoir (drum unit) is full. Defective waste toner sensor. Defective control PWB.
Turn the power switch off/on to restart the machine. If the error is not resolved, replace the drum unit. Replace the waste toner sensor. Replace the control PWB.
F000 Control PWB — Operation panel PWB communication error
Defective harness between operation panel PWB (YC1) and control PWB (YC7), or improper connector insertion. motor is ON. Defective operation panel PWB. Defective control PWB.
Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Replace the operation panel PWB. Replace the control PWB.
F020 Control PWB RAM checksum error
Defective main memory (RAM) on the control PWB. Defective expanded memory (DIMM).
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB. Replace the expanded memory (DIMM).
F040 Control PWB engine communication error A communication error is detected. Defective control PWB.
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB.
F041 Control PWB — scanner PWB communication error A communication error is detected. Defective control PWB or scanner PWB.
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB or scanner PWB.
F050 Control PWB engine checksum error
Some error may have occurred when downloading the firmware of the control PWB. Defective control PWB.
Download the firmware of the control PWB again. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB.
F186 Control PWB video data control error
Defective control PWB.
Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB.

C0030
Системная ошибка в управлении факсом
Обработка при помощи программного обеспечения факса была отключена из за проблем с оборудованием
Неисправность в системе управления факсом PWB
Заменить систему управления факсом PWB

C0070
Обнаружена несовместимость платы управления PWB
Обнаружена несовместимость при первичной инициализации системы управления факсом PWB. Никакие команды связи не проходят.
Дефект программного обеспечения факса
Установить программное обеспечение для факса

C0100
Ошибка при резервном копировании памяти устройства

Неисправна флеш память
Заменить плату управления PWB

C0120
Ошибка данных MAC адреса

Неисправность в плате управления PWB
Заменить плату управления PWB

C0130
Ошибка чтения/записи при резервном копировании

Неисправна флеш память
Заменить плату управления PWB

C0140
Ошибка при резервном копировании данных

Неисправна флеш память
Заменить плату управления PWB

C0150
Ошибка EEPROM платы управления PWB
Обнаружена ошибка связи PWB EEPROM (U17)
Неправильная установка PWB EEPROM (U17)
Проверить установку EEPROM (U17) и при необходимости исправить

C0170
Ошибка счетчика

1. Неисправность control PWB.

2. Повреждения данных PWB EEPROM (U17)

1. Заменить плату управления PWB.

2. Обратиться в сервис обслуживания

C0180
Номер аппарата не совпадает
Основной номер и номер двигателя не совпадают
1. Основная PWB или PWB двигателя была заменена.

2. Повреждения данных PWB EEPROM (U17)

1. U004 Задать номер.

2. Обратиться в сервис обслуживания

C0420
Ошибка связи с системой подачи бумаги
Ошибка коммуникации между платой PWB  и дополнительным устройством подачи бумаги
1. Неправильная установка устройства подачи бумаги

2. Повреждение провода между платой PWB (YC30) и интерфесным разъемом устройства подачи, либо разъем подключен неправильно.

3. Неисправен кабель между PF основной PWB и подачей бумаги, либо разъем не вставлен. Плата PF неисправна.

4. Неисправность control PWB

1. Еще раз внимательно прочитайте инструкцию по установке.

2. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

3. Убедитесь, что разъем подключен, а кабель не поврежден.Заменить печатную плату.

4. Заменить плату управления PWB.

C0830
Ошибка контрольной суммы прошивки FAX control PWB
Произошла ошибка контрольной суммы программы управления FAX control PWB
1. Дефект программного обеспечения факса.

2. Неисправность в системе управления факсом PWB

1. Установить программное обеспечение для факса.

2. Заменить плату управления факсом PWB

C0840
Неисправность RTС
Расхождение во времени между RTC  и текущим пять и более лет.
1. Неисправность control PWB

2. Отсоединена батарея.

1. Заменить плату управления PWB.

2. Визуально проверить и при необходимости исправить.

C0870
Проблема передачи данных большой емкости между FAX control PWB и control PWB
Не выполняется передача данных между FAX control PWB и control PWB, даже при повторе через заданный промежуток
 Неправильная установка  FAX control PWB

Переставить FAX control PWB

C0920
Ошибка файловой системы факса
Резервное копирование данных не производится по причине ошибки файловой системы флеш-памяти
Неисправность в системе управления факсом PWB
Заменить плату управления факсом PWB

C2000
Ошибка главного двигателя
Главный двигатель не выходит на готовность в течение 2 секунд после включения
1. Неисправен кабель между основным двигателем (CN1) и платой PWB (YC17) или разъем вставлен неправильно.

2. Неисправен привод основного двигателя.

3. Неисправен двигатель.

4. Неисправность control PWB

1. Вставьте разъем. Проверьте целостность кабеля.

2. Проверьте плавность вращения роликов и шестерней. При необходимости смажьте. Убедитесь в отсутсвии разрывов передач.

3. Заменить.

4. Заменить.

C2610
Ошибка дигателя устройства подачи бумаги
Двигатель устройства подачи бумаги лотка 2 не выходит на готовность более чем через 2 секунды после включения.
Неисправность кабеля между двигателем устройства подачи бумаги и control PWB (YC4).
 Вставьте разъем. Проверьте целостность кабеля (Обратитесь к инструкции)

C2620
Ошибка дигателя устройства подачи бумаги
Двигатель устройства подачи бумаги лотка 3 не выходит на готовность более чем через 2 секунды после включения.
Неисправность кабеля между двигателем устройства подачи бумаги и control PWB (YC4).
Вставьте разъем. Проверьте целостность кабеля (Обратитесь к инструкции)

C3100
Ошибка исходного положения ISU

1. Неисправность FFC между CCD PWB (YC1) и control PWB (YC8).

2. Неисправность FFC между control PWB (YC6) и сканера WPB (YC103) или неправильная установка FCC.

3. Неисправность датчика исходного положения.

4. Неисправность кабеля между двигателем ISU и сканером PWB (YC104) или разъем вставлен неправильно.

1. Заменить блок сканера ISU

2. Переставить FFC. Проверить на разрыв, при необходимости заменить.

3. Заменить датчик.

4. Вставьте разъем. Проверьте целостность кабеля.

C3200
Ошибка лампы экспозиции
Лампа экспозиции не включается
1. Повреждения FFC между сканером PWB (YC103) и control PWB (YC6), либо некорректная установка FFC.

2. Повреждения FFC между CCD PWB (YC1) и control PWB (YC8).

3. Неисправен кабель между CCD PWB (YC3) и LED приводом PWB (YC1) либо разъем не подключен.

4. Неисправен кабель между LED приводом PWB (YC2) и лампой экспонирования.

5. Лампа экспонирования вышла из строя.

6. Неисправен светодиодный привод.

1. Переустановите FFC. Проверьте целостность, при необходимости замените.

2. Заменить блок сканера.

3. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

4. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

5. Заменить лампу.

6. Заменить привод.

C3300
Ошибка AGC

1. Повреждения FFC между CCD PWB (YC1) и control PWB (YC8).

2. Лампа экспонирования вышла из строя.

3. Неисправность CCD PWB

4. Неисправность control PWB

1. Заменить блок сканера.

2. Заменить лампу.

3. Заменить CCD PWB

4. Заменить control PWB

C3500
Ошибка связи CPU — ASIC (CCD PWB)
Обнаружен код ошибки
1. Повреждения FFC между CCD PWB (YC1) и control PWB (YC8).

2. Неисправность CCD PWB.

3. Неисправность control PWB

1. Заменить блок сканера (ISU).

2. Заменить CCD PWB

3. Заменить control PWB

C4000
Ошибка полигон-мотора (блока лазерного сканера)
Полигон-мотор не выходит на готовность после 6 секунд после включения.
1. Поврежден кабель между полигон-мотором и control PWB (YC10) или разъем не вставлен.

2. Неисправен блок лазерного сканера.

3. Неисправность control PWB

1. Убедитесь, что разъем подключен, а кабель не поврежден. При необходимости — замените.

2. Заменить блок сканера.

3. Заменить control PWB

C4200
Ошибка BD  (блока лазерного сканера)

1. BD датчик не обнаруживает лазерный луч из-за скопления конденсата на зеркале.

2. Неисправен блок лазерного сканера.

1. Выключите питание машины минимум на 30 минут, затем снова включите, если это не помогает необходимо менять блок сканера.

2. Заменить блок сканера.

C6000
Выход из строя термо-элемента (фьюзера)
Температура фьюзера не поднимается после включения устройства.
1. Плохой контакт клемм термистора фьюзера.

2. Плохой контакт в местах подключения нагревателя термоблока.

3. Термисторы фьюзера установлены неправильно.

4 . Срабатывает термореле

5. Нагреватель фьюзера установлен неправильно

6. Выход из строя термо-элемента

1. Проверьте контакты.

2. Проверьте контакты.

3. Заменить блок закрепления

4. Заменить блок закрепления

5. Заменить блок закрепления

6. Заменить блок закрепления

C6020
Слишком высокая температура фьюзера
Термистор фьюзера обнаружил аномально высокую температуру.
Пробой термистора фьюзера
Заменить блок закрепления

C6030
Поврежден шлейф термистора термоэлемента
Значени на входе термистора равно 0
1. Плохой контакт в клеммах термистора.

2. Неисправен шлейф термистора

3. Термистор установлен некорректно

4. Срабатывает термореле

Проверить контакты

Заменить блок закрепления

C6400
Ошибка пересечения нуля
Сигнал пересечения нуля не достигает контрольной платы за указанное время
1. Неисправен кабель между PWB высокого напряжения(YC202) и control PWB (YC23) или разъем не вставлен

2. Дефект соединения между источником питания PWB (YC103) и PWB высокого напряжения (YC201)

3. Неисправен источник питания PWB

4. Неисправность control PWB

1. Переподключите коннектор.Убедитесь что кабель не поврежден.

2. Переподключите коннектор

3. Заменить источник питания

4. Заменить control PWB

C7990
Бункер отработки переполнен
Датчик тонера обнаружил, что бункер для отработки переполнен
1. Бункер отработки драм-юнита переполнен.

2. Неисправен датчик отработки

3. Неисправность control PWB

1. Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла замените драм-юнит.

2. Замените датчик.

3. Заменить control PWB

4. Очистите драм юнит (инструкция по очистке бункера отработанного тонера)

F000
Ошибка связи control PWB — панель управления PWB

1. Неисправность соединения панели управления PWB (YC1) и control PWB (YC7).

2. Неисправность панели управления

3. Неисправность control PWB

1. Переподключите коннектор.Убедитесь что кабель не поврежден.

2. Замените панель.

3. Заменить control PWB

F020
Ошибка контрольной суммы RAM control PWB

1. Неисправность основной микросхемы памяти (ОЗУ) на главной плате управления PWB

2. Неисправность платы расширения памяти (DIMM)

1. Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

2. Замените плату расширения (DIMM)

F040
Ошибка связи control PWB двигателя
Обнаружена ошибка связи
Неисправность control PWB
Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

F041
Ошибка связи между гланой платой управления и платой управления сканером
Обнаружена ошибка связи
Неисправна главная плата управления или управления сканером
Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB или scanner PWB

F050
Ошибка контрольной суммы платы управления двигателем

1. Такие ошибки могут происходить при обновлении прошивки control PWB

2. Неисправность control PWB

1. Скачайте прошивку снова

2. Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

F186
Ошибка управления видеоданными главной панели управления

Неисправность control PWB
Перезагрузите машину кратковременным выключением питания, если ошибка не исчезла, замените control PWB

Модератор: vetal

Прилепить пост

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑Приветствую всех. Kyosera FS-4100dn встал в ошибку 0150:0000000. В инете написано что нужно перепрошить. Пожалуйста поделитесь прошивкой на данный аппарат. Заранее спасибо. Почта

nforce@list.ru

Аватар пользователя

nFoRcE

  

Подошел к чернилам

  • Не в сети


Прилепить пост

Сообщение bmwmtv » Вт июн 28, 2016 5:17 am

Аватар пользователя

bmwmtv

  

Починил струйный принтер

  • Не в сети

Прилепить пост

Сообщение Ted » Вт июн 28, 2016 12:34 pm

Изменить размер шрифта ↓ВернутьИзменить размер шрифта ↑По прошивке не подскажу. Но вот у меня такая же ошибка на 2030dn… аппарат прошел 1300 отпечатков и благополучно слёг. То работает, то с150. По гарантии не сдать, ибо давно куплен был.
Есть у кого доводы? Кроватку пропаял на всякий случай, перешил аппарат, хотя он и так был с самой свежей прошивкой. вот жду пока она появится.

Добавлено спустя 2 минуты 6 секунд:

nFoRcE писал(а):Приветствую всех. Kyosera FS-4100dn встал в ошибку 0150:0000000. В инете написано что нужно перепрошить. Пожалуйста поделитесь прошивкой на данный аппарат. Заранее спасибо. Почта

nforce@list.ru

Если таришься в So-Kar, то можно у них прошивку слямзить.(это не реклама, реально в свое время, когда с ними работал, и маны давали, и прошивки)

Мне прошивка не помогла, через час снова вылезла с150…

Аватар пользователя

Ted

  

Заправил картридж

  • Не в сети






  • Taskalfa 180 ошибка «Е» и «Встряхните картр. с тонером»

    manik.76 в форуме Принтеры, МФУ, копиры формата A3

    3
    9931

    dviz
    Перейти к последнему сообщению
    Пн фев 20, 2017 1:35 pm
  • «ошибка принтера HSYNC»

    Sunat в форуме Xerox 3100 и иже с ним…

    10
    29480

    Sunat
    Перейти к последнему сообщению
    Сб май 10, 2014 6:19 am
  • Canon mf635cx ошибка «замятие»

    belocarsk в форуме Принтеры, МФУ, факсы, копиры формата A4

    8
    5377

    belocarsk
    Перейти к последнему сообщению
    Пн мар 04, 2019 12:23 pm
  • Samsung SCX 4300 V 1.15. Ошибка «Нет картриджа»

    PrintFree в форуме Картриджи, их заправка и дефекты.

    9
    10520

    С.Н.Н.
    Перейти к последнему сообщению
    Пт авг 19, 2011 7:16 pm
  • brother DCP 7030R «ошибка барабана»

    vg2804 в форуме Принтеры, МФУ, факсы, копиры формата A4

    14
    20085

    Rexvil
    Перейти к последнему сообщению
    Пт окт 09, 2020 8:01 am

Вернуться в Принтеры, МФУ, факсы, копиры формата A4

Кто сейчас на форуме

Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 72

Kyocera is a company that is known for manufacturing a variety of different printers. Kyocera printers are available in various price ranges and we know them for being high-quality printers.

These printers are also known for being environmentally friendly and efficient.

The company was founded in 1959 and was established in Kyoto, Japan. Kyocera has offices around the world and it has over 70,000 employees worldwide. Kyocera products are available in different countries around the world.

The company has headquarters in Kyoto, Japan, London, the United Kingdom, Singapore, China, and other countries. The company’s products are also available online or through retail stores in different countries around the world.

Tech Support 24/7

Ask a Tech Specialist Online

Connect with the Expert via email, text or phone. Include photos, documents, and more. Get step-by-step instructions from verified Tech Support Specialists.

Ask a Tech Specialist Online

On this page, you will find more information about the most common causes and most relevant solutions for the Printer error ‘C0150’. Do you need help straight away? Visit our support page.

Error information

What causes the C0150 error?

The Kyocera documentation indicates that error code ‘C0150’ is caused by the following problem: «Engine PWB EEPROM Backup Memory Device Problem EEPROM cannot be written or read».

Do you think there is another cause for this error? Let others know in the comments.

How to solve Kyocera Printer error C0150

We’ve created a list of solutions which you can follow if you want to solve this Printer problem yourself. Do you need more help? Visit our support page if you need professional support with Printer right away.

Tech Support 24/7

Ask a Tech Specialist Online

Connect with the Expert via email, text or phone. Include photos, documents, and more. Get step-by-step instructions from verified Tech Support Specialists.

Ask a Tech Specialist Online

Verified solution

If you have a Kyocera printer or if you encounter errors while using your printer, then you might encounter the error code Kyocera C0150 on your device’s screen.

This error can occur when there is an issue with your device or it can occur when there is an issue with your power supply or the USB port on your computer or printer itself.

Sometimes, common device errors or server problems can also cause this error. To fix this error, you need to try a few solutions.

Try reseating the electrical cables and other hardware. Check if the USB port is properly seated. If not, try replacing the CIS copier parts.

If this does not work, try replacing the CIS fan. You should try this to see if the problem is with the CIS cooling fan. If it does not work, you will need to replace the CIS cooling fan.

You may need to contact the company to get more information about the cause of the problem.

If you still have this error message, contact a professional to fix the problem. This will help a professional diagnose whether the problem is with the printer or the electrical wiring.

You can also contact customer service to try to resolve the error. If you still have this problem, contact CIS Support by calling their customer support number or visiting their website.

When the error code appears on your screen, customer support will want you to send them a copy of the code. They will give you instructions on what to do for them to resolve your problem.

Have you found a solution yourself, but it is not in the list? Share your solution in the comments below.

Need more help?

Do you need more help?

Tech experts are ready to answer your questions.

Ask a question

Понравилась статья? Поделить с друзьями:

Интересное по теме:

  • Kyocera fs 6525mfp ошибка f248
  • Kyocera fs 6525mfp ошибка f000
  • Kyocera fs 6525mfp ошибка 0180
  • Kyocera fs 6525mfp 6050 ошибка
  • Kyocera fs 6525 ошибка 0180

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии