Kyocera fs 1300d коды ошибок

Коды ошибок Kyocera FS-1300D

Отсчет начинать после того, как загорятся все красные индикаторы без зеленых.
Должно получиться четырехзначное число.

Code Description Causes
0150 Control PWB EEPROM error
Detecting control PWB EEPROM (U300) communication error.
Improper installation control PWB EEPROM (U300). Defective control PWB.
0420 Paper feeder communication error
Communication error between control PWB and optional paper feeder.
Improper installation paper feeder. Defective harness between control PWB (YC318) and paper feeder interface connector, or improper connector insertion. Defective control PWB. Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. Defective PF main- PWB.
2000 Main motor error
The main motor ready input is not given for 2 s during the main motor is ON.
Defective harness between main motor (CN1) and control PWB (YC305), or improper connector insertion. Defective drive transmission system of the main motor. Defective main motor. Defective control PWB.
2610 PF paper feed motor error (Paper feeder 1)
The PF paper feed motor of paper feeder 1 ready input is not given for 2 s during the PF paper feed motor is ON.
Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Defective drive transmission system of the PF paper feed motor.YC4). Defective PF main motor. Defective control PWB.
2620 PF paper feed motor error (Paper feeder 2)
The PF paper feed motor of paper feeder 2 ready input is not given for 2 s during the PF paper feed motor is ON.
Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Defective drive transmission system of the PF paper feed motor. Defective PF main motor. Defective control PWB.
4000 Polygon motor (laser scanner unit) error
The polygon motor ready input is not given for 6 s during the polygon motor is ON.
Defective harness between polygon motor and control PWB (YC319), or improper connector insertion. Defective laser scanner unit. Defective control PWB.
6000 Broken fuser heater lamp wire
The fuser temperature does not rise after the fuser heater lamp has been turned on.
Poor contact in the fuser thermistor connector terminals. Poor contact in the fuser heater lamp connector terminals. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater lamp installed incorrectly. Broken fuser heater lamp wire.
6020 Abnormally high fuser thermistor temperature
Fuser thermistor detects abnormally temperature.
Shorted fuser thermistor. Defective control PWB.
6030 Broken fuser thermistor wire
Input from fuser thermistor is 0 (A/D value).
Poor contact in the fuser thermistor connector terminals. Broken fuser thermistor wire. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater lamp installed incorrectly. Broken fuser heater lamp wire.
6400 Zero cross signal error
The zero cross signal does not reach the control PWB for specified time.
Defective harness between high voltage PWB (YC202) and control PWB (YC311), or improper connector insertion. Defective harness between power source PWB (YC103) and high voltage PWB (YC201), or improper connector insertion. Defective power source PWB. Defective control PWB.
F010 Control PWB checksum error Defective code ROM (flash memory). Defective control PWB.
F020 Control PWB RAM checksum error Defective main memory (RAM) on the control PWB. Defective expanded memory (DIMM).
F030 Control PWB general failure Defective control PWB.
F040 Control PWB engine communication error Defective control PWB.
F050 Control PWB engine checksum error

Some error may have occurred when downloading the firmware of the control PWB. Defective control PWB.

Популярные сообщения из этого блога

@Echo Off SetLocal EnableDelayedExpansion Set file=e:\Temp1\temp.txt Set newfile=e:\Temp1\newtemp.txt (For /F «tokens=* usebackq delims=» %%a In («%file%») Do (   Set ta=%%a   Echo !ta:~0,-1! ))>»%newfile%» Нагло стырено с просторов Интернет

Постоянно забываю как убрать принудительное текстовое форматирование в таблицах OpenOffice, поэтому просто копирую эту статью из базы знаний: Символ «’» (апостроф) Если перед числами в строке ввода стоит символ «’», то в этом случае цифры не распознаются как числа. Символ «’» (апостроф) является символом принудительного форматирования данных «как текст», поэтому он не отображается в ячейках; увидеть его можно только в строке ввода перед данными. «Язык формул» электронных таблиц разработан задолго до появления MS Windows и Microsoft Office. Символ «апостроф» в начале содержимого ячейки всегда был символом принудительного форматирования содержимого «как текст». Данный способ форматирования является преимущественным перед форматом ячейки. Так работали Quatro Pro, Super Calc, таблицы Lotus 1-2-3. Так работают и все современные электронные таблицы. «’» перед цифровыми значениями следует использовать, когда вводятся константы, не являющиеся числами. Например

@echo off SetLocal EnableDelayedExpansion rem Определяем переменные SET CONF=ftp.cnf SET FILELIST=f.txt SET HOST=ftp.host.lan SET USERNAME=ftpuser SET PASSWORD=PaS$w0Rd rem  Создаем файл конфигурации для автоматизации работы ftp-клиента rem в котором сканируем файлы по маске с учетом регистра echo.open %HOST%> %CONF% echo.%USERNAME%>> %CONF% echo.%PASSWORD%>> %CONF% echo.binary>> %CONF% echo.ls *_IN.zip>> %CONF% echo.ls *_IN.ZIP>> %CONF% echo.ls *_in.zip>> %CONF% echo.ls *_in.ZIP>> %CONF% echo.bye>> %CONF% rem Запускаем ftp-клиент в автоматическом режиме, rem выводим результаты просмотра каталога в текстовый файл, rem  фильтруя выводимые имена файлов ftp -s:%CONF% | findstr /i «[a-z,_,0-9]_IN.zip» > %FILELIST% rem Вторично создаем файл конфигурации echo.open %HOST%> %CONF% echo.%USERNAME%>> %CONF% echo.%PASSWORD%>> %CONF% echo.binary>>%CONF% rem Записываем в конфигу

Ошибки Kyocera ECOSYS M2030dn

Ошибки Kyocera ECOSYS M2030pn

Ошибки Kyocera ECOSYS M2035dn

Ошибки Kyocera ECOSYS M2040dn

Ошибки Kyocera ECOSYS M2135dn

Ошибки Kyocera ECOSYS M2530dn

Ошибки Kyocera ECOSYS M2535dn

Ошибки Kyocera ECOSYS M2540dn

Ошибки Kyocera ECOSYS M2540dw

Ошибки Kyocera ECOSYS M2635dn

Ошибки Kyocera ECOSYS M2635dw

Ошибки Kyocera ECOSYS M2640idw

Ошибки Kyocera ECOSYS M3040dn

Ошибки Kyocera ECOSYS M3040idn

Ошибки Kyocera ECOSYS M3145dn

Ошибки Kyocera ECOSYS M3145idn

Ошибки Kyocera ECOSYS M2735dw

Ошибки Kyocera ECOSYS M3540dn

Ошибки Kyocera ECOSYS M3540idn

Ошибки Kyocera ECOSYS M3550idn

Ошибки Kyocera ECOSYS M3560idn

Ошибки Kyocera ECOSYS M3645dn

Ошибки Kyocera ECOSYS M3645idn

Ошибки Kyocera ECOSYS M3655idn

Ошибки Kyocera ECOSYS M3660idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M3860idn

Ошибки Kyocera ECOSYS M4125idn

Ошибки Kyocera ECOSYS M4132idn

Ошибки Kyocera ECOSYS M5521cdn

Ошибки Kyocera ECOSYS M5521cdw

Ошибки Kyocera ECOSYS M5526cdn

Ошибки Kyocera ECOSYS M5526cdw

Ошибки Kyocera ECOSYS M6026cdn

Ошибки Kyocera ECOSYS M6026cidn

Ошибки Kyocera ECOSYS M6030cdn

Ошибки Kyocera ECOSYS M6035cidn

Ошибки Kyocera ECOSYS M6230cidn

Ошибки Kyocera ECOSYS M6235cidn

Ошибки Kyocera ECOSYS M6526cdn

Ошибки Kyocera ECOSYS M6526cidn

Ошибки Kyocera ECOSYS M6530cdn

Ошибки Kyocera ECOSYS M6535cidn

Ошибки Kyocera ECOSYS M6630cidn

Ошибки Kyocera ECOSYS M6635cidn

Ошибки Kyocera ECOSYS M8124cidn

Ошибки Kyocera ECOSYS M8130cidn

Ошибки Kyocera ECOSYS P2035d

Ошибки Kyocera ECOSYS P2040dn

Ошибки Kyocera ECOSYS P2040dw

Ошибки Kyocera ECOSYS P2135d

Ошибки Kyocera ECOSYS P2135dn

Ошибки Kyocera ECOSYS P2235dn

Ошибки Kyocera ECOSYS P2235dw

Ошибки Kyocera ECOSYS P3045dn

Ошибки Kyocera ECOSYS P3050dn

Ошибки Kyocera ECOSYS P3055dn

Ошибки Kyocera ECOSYS P3060dn

Ошибки Kyocera ECOSYS P3145dn

Ошибки Kyocera ECOSYS P3150dn

Ошибки Kyocera ECOSYS P3155dn

Ошибки Kyocera ECOSYS P3160dn

Ошибки Kyocera ECOSYS P3260dn

Ошибки Kyocera ECOSYS P4035dn

Ошибки Kyocera ECOSYS P4040dn

Ошибки Kyocera ECOSYS P5021cdn

Ошибки Kyocera ECOSYS P5021cdw

Ошибки Kyocera ECOSYS P5026cdn

Ошибки Kyocera ECOSYS P5026cdw

Ошибки Kyocera ECOSYS P6021cdn

Ошибки Kyocera ECOSYS P6026cdn

Ошибки Kyocera ECOSYS P6030cdn

Ошибки Kyocera ECOSYS P6035cdn

Ошибки Kyocera ECOSYS P6130cdn

Ошибки Kyocera ECOSYS P6230cdn

Ошибки Kyocera ECOSYS P6235cdn

Ошибки Kyocera ECOSYS P7035cdn

Ошибки Kyocera ECOSYS P7040cdn

Ошибки Kyocera ECOSYS P7240cdn

Ошибки Kyocera ECOSYS P8060cdn

Ошибки Kyocera FS-C8600DN

Ошибки Kyocera FS-C8650DN

Ошибки Kyocera FS1016MFP

Ошибки Kyocera FS1018MFP

Ошибки Kyocera FS1020MFP

Ошибки Kyocera FS1024MFP

Ошибки Kyocera FS1025MFP

Ошибки Kyocera FS1028MFP

Ошибки Kyocera FS1030MFP

Ошибки Kyocera FS1035MFP

Ошибки Kyocera FS1040

Ошибки Kyocera FS1050

Ошибки Kyocera FS1060DN

Ошибки Kyocera FS1100

Ошибки Kyocera FS1110

Ошибки Kyocera FS1116MFP

Ошибки Kyocera FS1118MFP

Ошибки Kyocera FS1120

Ошибки Kyocera FS1120MFP

Ошибки Kyocera FS1124MFP

Ошибки Kyocera FS1125MFP

Ошибки Kyocera FS1128MFP

Ошибки Kyocera FS1130MFP

Ошибки Kyocera FS1135MFP

Ошибки Kyocera FS1200

Ошибки Kyocera FS1220MFP

Ошибки Kyocera FS1300D

Ошибки Kyocera FS1320D

Ошибки Kyocera FS1320MFP

Ошибки Kyocera FS1325MFP

Ошибки Kyocera FS1350DN

Ошибки Kyocera FS1370DN

Ошибки Kyocera FS1500

Ошибки Kyocera FS6020

Ошибки Kyocera FS6025MFP

Ошибки Kyocera FS6025MFPB

Ошибки Kyocera FS6030MFP

Ошибки Kyocera FS6500

Ошибки Kyocera FS6525MFP

Ошибки Kyocera FS6530MFP

Ошибки Kyocera FS6700

Ошибки Kyocera FS6900

Ошибки Kyocera FS6950DN

Ошибки Kyocera FS8000CD

Ошибки Kyocera FS8000CN

Ошибки Kyocera FS8100DN

Ошибки Kyocera TASKalfa 180

Ошибки Kyocera TASKalfa 1800

Ошибки Kyocera TASKalfa 1801

Ошибки Kyocera TASKalfa 181

Ошибки Kyocera TASKalfa 205c

Ошибки Kyocera TASKalfa 220

Ошибки Kyocera TASKalfa 2200

Ошибки Kyocera TASKalfa 2201

Ошибки Kyocera TASKalfa 221

Ошибки Kyocera TASKalfa 2420w

Ошибки Kyocera TASKalfa 2460ci

Ошибки Kyocera TASKalfa 2470ci

Ошибки Kyocera TASKalfa 250ci

Ошибки Kyocera TASKalfa 2510i

Ошибки Kyocera TASKalfa 2520i

Ошибки Kyocera TASKalfa 255

Ошибки Kyocera TASKalfa 2550ci

Ошибки Kyocera TASKalfa 2551ci

Ошибки Kyocera TASKalfa 2552ci

Ошибки Kyocera TASKalfa 2553ci

Ошибки Kyocera TASKalfa 255b

Ошибки Kyocera TASKalfa 255c

Ошибки Kyocera TASKalfa 265ci

Ошибки Kyocera TASKalfa 300ci

Ошибки Kyocera TASKalfa 300i

Ошибки Kyocera TASKalfa 3010i

Ошибки Kyocera TASKalfa 3011i

Ошибки Kyocera TASKalfa 305

Ошибки Kyocera TASKalfa 3050ci

Ошибки Kyocera TASKalfa 3051ci

Ошибки Kyocera TASKalfa 306ci

Ошибки Kyocera TASKalfa 307ci

Ошибки Kyocera TASKalfa 308ci

Ошибки Kyocera TASKalfa 3212i

Ошибки Kyocera TASKalfa 3252ci

Ошибки Kyocera TASKalfa 3253ci

Ошибки Kyocera TASKalfa 3500i

Ошибки Kyocera TASKalfa 3501i

Ошибки Kyocera TASKalfa 350ci

Ошибки Kyocera TASKalfa 3510i

Ошибки Kyocera TASKalfa 3511i

Ошибки Kyocera TASKalfa 3550ci

Ошибки Kyocera TASKalfa 3551ci

Ошибки Kyocera TASKalfa 3552ci

Ошибки Kyocera TASKalfa 3553ci

Ошибки Kyocera TASKalfa 356ci

Ошибки Kyocera TASKalfa 358ci

Ошибки Kyocera TASKalfa 4002i

Ошибки Kyocera TASKalfa 4003i

Ошибки Kyocera TASKalfa 400ci

Ошибки Kyocera TASKalfa 4012i

Ошибки Kyocera TASKalfa 4052ci

Ошибки Kyocera TASKalfa 4053ci

Ошибки Kyocera TASKalfa 406ci

Ошибки Kyocera TASKalfa 408ci

Ошибки Kyocera TASKalfa 420i

Ошибки Kyocera TASKalfa 4500i

Ошибки Kyocera TASKalfa 4501i

Ошибки Kyocera TASKalfa 4550ci

Ошибки Kyocera TASKalfa 4551ci

Ошибки Kyocera TASKalfa 4820w

Ошибки Kyocera TASKalfa 5002i

Ошибки Kyocera TASKalfa 5003i

Ошибки Kyocera TASKalfa 500ci

Ошибки Kyocera TASKalfa 5052ci

Ошибки Kyocera TASKalfa 5053ci

Ошибки Kyocera TASKalfa 508ci

Ошибки Kyocera TASKalfa 520i

Ошибки Kyocera TASKalfa 5500i

Ошибки Kyocera TASKalfa 5501i

Ошибки Kyocera TASKalfa 550c

Ошибки Kyocera TASKalfa 552ci

Ошибки Kyocera TASKalfa 5550ci

Ошибки Kyocera TASKalfa 5551ci

Ошибки Kyocera TASKalfa 6002i

Ошибки Kyocera TASKalfa 6003i

Ошибки Kyocera TASKalfa 6052ci

Ошибки Kyocera TASKalfa 6053ci

Ошибки Kyocera TASKalfa 620

Ошибки Kyocera TASKalfa 6500i

Ошибки Kyocera TASKalfa 6501i

Ошибки Kyocera TASKalfa 650c

Ошибки Kyocera TASKalfa 6550ci

Ошибки Kyocera TASKalfa 6551ci

Ошибки Kyocera TASKalfa 7002i

Ошибки Kyocera TASKalfa 7003i

Ошибки Kyocera TASKalfa 7052ci

Ошибки Kyocera TASKalfa 7353ci

Ошибки Kyocera TASKalfa 750c

Ошибки Kyocera TASKalfa 7550ci

Ошибки Kyocera TASKalfa 7551ci

Ошибки Kyocera TASKalfa 8000i

Ошибки Kyocera TASKalfa 8001i

Ошибки Kyocera TASKalfa 8002i

Ошибки Kyocera TASKalfa 8003i

Ошибки Kyocera TASKalfa 8052ci

Ошибки Kyocera TASKalfa 820

Ошибки Kyocera TASKalfa 8353ci

Ошибки Kyocera TASKalfa 9002i

Ошибки Kyocera TASKalfa 9003i

– Printer model: Kyocera FS1300D
– Fix Error codes on Kyocera FS1300D model and its description:

  • Code: 0150
  • Description: Control PWB EEPROM error
    Detecting control PWB EEPROM (U300) communication error.
  • Causes: Improper installation control PWB EEPROM (U300). Defective control PWB.
  • Remedy: Improper installation control PWB EEPROM (U300). Check the installation of the EEPROM (U300) and remedy if necessary.
    Defective control PWB. Replace the control PWB.
  • Code: 0420
  • Description: Paper feeder communication error
    Communication error between control PWB and optional paper feeder.
  • Causes: Improper installation paper feeder. Defective harness between control PWB (YC318) and paper feeder interface connector, or improper connector insertion. Defective control PWB. Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. Defective PF main- PWB.
  • Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
    Defective harness between control PWB (YC318) and paper feeder interface connector, or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective control PWB. Replace the control PWB.
    Defective harness between PF main PWB (YC5) and paper feeder interface connector, or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder).
    Defective PF main- PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 2000
  • Description: Main motor error
    The main motor ready input is not given for 2 s during the main motor is ON.
  • Causes: Defective harness between main motor (CN1) and control PWB (YC305), or improper connector insertion. Defective drive transmission system of the main motor. Defective main motor. Defective control PWB.
  • Remedy: Defective harness between main motor (CN1) and control PWB (YC305), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective main motor. Replace the main motor.
    Defective control PWB. Replace the control PWB.
  • Code: 2610
  • Description: PF paper feed motor error (Paper feeder 1)
    The PF paper feed motor of paper feeder 1 ready input is not given for 2 s during the PF paper feed motor is ON.
  • Causes: Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Defective drive transmission system of the PF paper feed motor.YC4). Defective PF main motor. Defective control PWB.
  • Remedy: Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder).
    Defective drive transmission system of the PF paper feed motor. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective PF main motor. Replace the PF main motor (Refer to the service manual for the paper feeder).
    Defective control PWB. Replace the control PWB.
  • Code: 2620
  • Description: PF paper feed motor error (Paper feeder 2)
    The PF paper feed motor of paper feeder 2 ready input is not given for 2 s during the PF paper feed motor is ON.
  • Causes: Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Defective drive transmission system of the PF paper feed motor. Defective PF main motor. Defective control PWB.
  • Remedy: Defective harness between PF paper feed motor and PF main PWB (YC4), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness (Refer to the service manual for the paper feeder).
    Defective drive transmission system of the PF paper feed motor. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
    Defective PF main motor. Replace the PF main motor (Refer to the service manual for the paper feeder).
    Defective control PWB. Replace the control PWB.
  • Code: 4000
  • Description: Polygon motor (laser scanner unit) error
    The polygon motor ready input is not given for 6 s during the polygon motor is ON.
  • Causes: Defective harness between polygon motor and control PWB (YC319), or improper connector insertion. Defective laser scanner unit. Defective control PWB.
  • Remedy: Defective harness between polygon motor and control PWB (YC319), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective laser scanner unit. Replace the laser scanner unit.
    Defective control PWB. Replace the control PWB.
  • Code: 6000
  • Description: Broken fuser heater lamp wire
    The fuser temperature does not rise after the fuser heater lamp has been turned on.
  • Causes: Poor contact in the fuser thermistor connector terminals. Poor contact in the fuser heater lamp connector terminals. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater lamp installed incorrectly. Broken fuser heater lamp wire.
  • Remedy: Poor contact in the fuser thermistor connector terminals. Reinsert the connector.
    Poor contact in the fuser heater lamp connector terminals. Reinsert the connector.
    Fuser thermistor installed incorrectly. Replace the fuser unit.
    Fuser thermal cutout triggered. Replace the fuser unit.
    Fuser heater lamp installed incorrectly. Replace the fuser unit.
    Broken fuser heater lamp wire. Replace the fuser unit.
  • Code: 6020
  • Description: Abnormally high fuser thermistor temperature
    Fuser thermistor detects abnormally temperature.
  • Causes: Shorted fuser thermistor. Defective control PWB.
  • Remedy: Shorted fuser thermistor. Replace the fuser unit.
    Defective control PWB. Replace the control PWB.
  • Code: 6030
  • Description: Broken fuser thermistor wire
    Input from fuser thermistor is 0 (A/D value).
  • Causes: Poor contact in the fuser thermistor connector terminals. Broken fuser thermistor wire. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater lamp installed incorrectly. Broken fuser heater lamp wire.
  • Remedy: Poor contact in the fuser thermistor connector terminals. Reinsert the connector.
    Broken fuser thermistor wire. Replace the fuser unit.
    Fuser thermistor installed incorrectly. Replace the fuser unit.
    Fuser thermal cutout triggered. Replace the fuser unit.
    Fuser heater lamp installed incorrectly. Replace the fuser unit.
    Broken fuser heater lamp wire. Replace the fuser unit.
  • Code: 6400
  • Description: Zero cross signal error
    The zero cross signal does not reach the control PWB for specified time.
  • Causes: Defective harness between high voltage PWB (YC202) and control PWB (YC311), or improper connector insertion. Defective harness between power source PWB (YC103) and high voltage PWB (YC201), or improper connector insertion. Defective power source PWB. Defective control PWB.
  • Remedy: Defective harness between high voltage PWB (YC202) and control PWB (YC311), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective harness between power source PWB (YC103) and high voltage PWB (YC201), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
    Defective power source PWB. Replace the power source PWB.
    Defective control PWB. Replace the control PWB.
  • Code: F010
  • Description: Control PWB checksum error
  • Causes: Defective code ROM (flash memory). Defective control PWB.
  • Remedy: Defective code ROM (flash memory). Turn the power switch off/on to restart the printer. If the error is not resolved, replace the control PWB.
    Defective control PWB. Replace the control PWB.
  • Code: F020
  • Description: Control PWB RAM checksum error
  • Causes: Defective main memory (RAM) on the control PWB. Defective expanded memory (DIMM).
  • Remedy: Defective main memory (RAM) on the control PWB. Turn the power switch off/on to restart the printer. If the error is not resolved, replace control PWB.
    Defective expanded memory (DIMM). Replace the expanded memory (DIMM).
  • Code: F030
  • Description: Control PWB general failure
  • Causes: Defective control PWB.
  • Remedy: Turn the power switch off/on to restart the printer. If the error is not resolved, replace control PWB.
  • Code: F040
  • Description: Control PWB engine communication error
  • Causes: Defective control PWB.
  • Remedy: Turn the power switch off/on to restart the printer. If the error is not resolved, replace control PWB.
  • Code: F050
  • Description: Control PWB engine checksum error
  • Causes: Some error may have occurred when downloading the firmware of the control PWB. Defective control PWB.
  • Remedy: Some error may have occurred when downloading the firmware of the control PWB. Download the firmware of the control PWB again using the memory card.
    Defective control PWB. Turn the power switch off/on to restart the printer. If the error is not resolved, replace control PWB.
  • Code: F226
  • Description: Control PWB video data control error
  • Causes: Defective control PWB.
  • Remedy: Turn the power switch off/on to restart the printer. If the error is not resolved, replace control PWB.

Kyocera FS1300D error code

– Kyocera FS1300D printer Error Codes and quick guide to troubleshooting:

















































– Buy WIC Reset key on my online store: https://shop.nguyendangnam.com/product/epson-sc-p5050-wic-reset-utility-tool/
– Free Download Epson in specific model: https://dnasofts.com/download-epson-wf-m5799-driver-firmware-and-manuals/

Source:
https://dnasofts.com
https://shop.nguyendangnam.com/
https://nguyendangnam.me/
https://chiplessprinter.com/reset-epson-waste-ink-pad-counter.html

Contact us to get support with Kyocera FS1300D Error case

Telegram: https://t.me/hyperaktiv
Facebook: https://www.facebook.com/dngnm/

Indicator

5-8

Meaning

The toner is running low.

The toner has run out.

Unable to print with the specified

resolution due to insufficient

memory.

CF card is not formatted.

Specified file not found.

The current printing cannot be

continued.

Unable to print due to insufficient

memory.

Unable to print as the data is too

complicated.

If the indicators light or flash repeatedly in manners not described

above for normal or maintenance indication, a service error has

probably occurred. Turn the printer off by the power switch, wait 5

seconds and then turn the printer on again. This may clear the error.

Even if the error is not cleared, contact your service technician.

Remedy

Have a new toner container ready.

Replace with a new toner container.

After replacing the toner container,

clean the inside of the printer.

Add the expansion memory to the

printer.

Format the CF card.

Press [GO] to continue processing.

Press [Cancel] to cancel processing.

Press [GO] to continue processing.

Press [Cancel] to cancel processing.

Install the expansion memory in the

printer. Press [GO] to continue

processing. Press [Cancel] to cancel

processing.

Press [GO] to continue processing.

Press [Cancel] to cancel processing.

Troubleshooting

Устранение неисправностей

5-7

Индикация техобслуживания

Таблица ниже показывает комбинации индикаторов, когда требуется 
вмешательство пользователя. Предполагается, что принтер 
находится в режиме соединения с компьютером и обрабатывает 
данные.

Индикатор

Описание

Меры устранения

В кассетеуниверсальном 
лотке
 или Ручной подаче нет 
бумаги.

Загрузите бумагу в источник бумаги.

Неправильно вставлена 
кассета.

Вставьте кассету полностью в 
принтер.

Открыта верхняя крышка.

Закройте крышку.

Нет кассеты в податчике 
бумаги
 или кассета, указанная 
как источник бумаги, не 
вставлена правильно.

Заново вставьте кассету и затем 
попробуйте печатать.

Не установлены блок 
обработки
 или контейнер с 
тонером
.

Установите блок обработки или 
контейнер с тонером.

В кассете нет бумаги, 
указанной в драйвере принтера.

Загрузите бумагу в кассету (#[1 или 
2]) и затем перезапустите печать. 
Источник бумаги можно изменить, 
нажав [GO].

Форматы бумаги не 
соответствуют.

Если формат бумаги в источнике 
бумаги отличается от формата 
бумаги и типа, указанных в драйвере 
принтера, можно печатать при 
помощи подачи бумаги из 
универсального лоткаили Ручной 
подачи
. Для начала печати загрузите 
в универсальный лотокили Ручную 
подачу
 правильный формат и тип 
бумаги и нажмите [GO].

Если хотите, чтобы бумага 
подавалась из другого источника, 
чем универсальный лотокили 
Ручная подача, можете изменить 
источник бумаги нажатием [GO].

Если бумага, подаваемая из 
универсального лотка  или Ручной 
подачи
, по формату отличается от 
заданной, она застрянет.

Понравилась статья? Поделить с друзьями:

Интересное по теме:

  • Kyocera 5002 ошибка c3100
  • Kyocera 4301 ошибка
  • Kyocera 4300 ошибка 6120
  • Kyocera 4200 ошибка f24b
  • Kyocera 4200 ошибка 0150

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии