I’m trying to import a text file of 200k rows into sql server using sql server management studio 17. but its showing the following error:

Error 0xc0202009: Data Flow Task 1: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x80004005.
An OLE DB record is available.  Source: "Microsoft OLE DB Provider for SQL Server"  Hresult: 0x80004005  Description: "Invalid character value for cast specification.".
 (SQL Server Import and Export Wizard)

Error 0xc020901c: Data Flow Task 1: There was an error with Destination - DimStudent.Inputs[Destination Input].Columns[DateOfBirth] on Destination - DimStudent.Inputs[Destination Input]. The column status returned was: "Conversion failed because the data value overflowed the specified type.".
 (SQL Server Import and Export Wizard)


Error 0xc0209029: Data Flow Task 1: SSIS Error Code DTS_E_INDUCEDTRANSFORMFAILUREONERROR.  The "Destination - DimStudent.Inputs[Destination Input]" failed because error code 0xC020907A occurred, and the error row disposition on "Destination - DimStudent.Inputs[Destination Input]" specifies failure on error. An error occurred on the specified object of the specified component.  There may be error messages posted before this with more information about the failure.
 (SQL Server Import and Export Wizard)

Error 0xc0047022: Data Flow Task 1: SSIS Error Code DTS_E_PROCESSINPUTFAILED.  The ProcessInput method on component "Destination - DimStudent" (158) failed with error code 0xC0209029 while processing input "Destination Input" (171). The identified component returned an error from the ProcessInput method. The error is specific to the component, but the error is fatal and will cause the Data Flow task to stop running.  There may be error messages posted before this with more information about the failure.
 (SQL Server Import and Export Wizard)

Error 0xc02020c4: Data Flow Task 1: The attempt to add a row to the Data Flow task buffer failed with error code 0xC0047020.
 (SQL Server Import and Export Wizard)

Error 0xc0047038: Data Flow Task 1: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED.  The PrimeOutput method on Source - DimStudent_txt returned error code 0xC02020C4.  The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing.  There may be error messages posted before this with more information about the failure.
 (SQL Server Import and Export Wizard)

I’m new to this. it would be great if someone could tell how to resolve this issue.

James Z's user avatar

James Z

12.2k10 gold badges24 silver badges44 bronze badges

asked May 30, 2017 at 5:34

goonerboi's user avatar

The error message states:

"Conversion failed because the data value overflowed the specified type.".

One of the rows has a value that does not fit into the destination table for some reason. You didn’t specify the datatypes, but I am guessing the output column might not be a proper date/time column.

However, without knowing the table setup and/or seeing some of the data, we can only guess.

answered May 30, 2017 at 6:13

SchmitzIT's user avatar

SchmitzITSchmitzIT

9,2659 gold badges65 silver badges92 bronze badges

Ran into same error, I had columns that were set not to allow null by the auto import. Set them to allow nulls and everything completed.

answered Nov 16, 2022 at 21:44

Brad Gall's user avatar

I’m trying to export some information from SQL Server. The SQL runs fine in the SQL Management Studio, but when I try to export it gives me the following errors.
I’ve had issues similar to this before and adding the

SET ANSI_WARNINGS OFF

line fixed it. That line is not working this time.

EDIT:
I’ve tried with the SQL SELECT * FROM Table and still get the error.

The SQL is basically:

SELECT [Table]
      , CASE WHEN [UserID] IS NULL THEN '' ELSE [UserID] END AS [UserID]
      , CASE WHEN [fieldname] IS NULL THEN '' ELSE [fieldname] END AS [fieldname]
      , CASE WHEN [fieldname] IS NULL THEN '' ELSE [fieldname] END AS [fieldname]
      , CASE WHEN [fieldname] IS NULL THEN '' ELSE [fieldname] END AS [fieldname]
                             ... more ...
      , CASE WHEN [fieldname] IS NULL THEN '' ELSE [fieldname] END AS [fieldname]
      CASE WHEN [fieldname] IS NULL THEN '' ELSE [fieldname] END AS [fieldname]
  FROM Table

Errors:

Messages
Error 0xc0202009: Data Flow Task 1: SSIS Error Code DTS_E_OLEDBERROR.  An OLE DB error has occurred. Error code: 0x00040EDA.
 (SQL Server Import and Export Wizard)

Error 0xc0209029: Data Flow Task 1: SSIS Error Code DTS_E_INDUCEDTRANSFORMFAILUREONERROR.  The "input "Destination Input" (174)" failed because error code 0xC020907B occurred, and the error row disposition on "input "Destination Input" (174)" specifies failure on error. An error occurred on the specified object of the specified component.  There may be error messages posted before this with more information about the failure.
 (SQL Server Import and Export Wizard)

Error 0xc0047022: Data Flow Task 1: SSIS Error Code DTS_E_PROCESSINPUTFAILED.  The ProcessInput method on component "Destination - Query" (163) failed with error code 0xC0209029 while processing input "Destination Input" (174). The identified component returned an error from the ProcessInput method. The error is specific to the component, but the error is fatal and will cause the Data Flow task to stop running.  There may be error messages posted before this with more information about the failure.
 (SQL Server Import and Export Wizard)

marc_s's user avatar

marc_s

734k176 gold badges1332 silver badges1460 bronze badges

asked Sep 17, 2010 at 1:03

Justin808's user avatar

Justin808Justin808

20.9k46 gold badges160 silver badges265 bronze badges

0

I’m chalking this up to Microsoft being an idiot.

I have some fields that are dates. The dates all work just fine for the export with the exception of on date from 1790. If i convert all dates older than 1800 to blank, the export works just fine.

How any of those errors relates to the issue, you got me.

Way to go M$

answered Sep 17, 2010 at 2:19

Justin808's user avatar

Justin808Justin808

20.9k46 gold badges160 silver badges265 bronze badges

2

  • Remove From My Forums
  • Question

  • I’ve seen the previous threads on this (although maybe not all of them). However, i don’t think I’m getting the error for the same reason. The full error I’m getting is:
    — Pre-execute (Error)
    Messages
    Error 0xc0202009: {F1B3B35C-FAE3-48F6-A169-4E4D8D99F9B6}: An OLE DB error has occurred. Error code: 0x80004005.
    An OLE DB record is available.  Source: «Microsoft JET Database Engine»  Hresult: 0x80004005  Description: «Unspecified error».
     (SQL Server Import and Export Wizard)

     Error 0xc020801c: Data Flow Task: The AcquireConnection method call to the connection manager «DestinationConnectionExcel» failed with error code 0xC0202009.
     (SQL Server Import and Export Wizard)

     Error 0xc004701a: Data Flow Task: component «Destination 64 — production_effectivities» (7042) failed the pre-execute phase and returned error code 0xC020801C.
     (SQL Server Import and Export Wizard)

     The entire package is running on one machine. The data source is SQL Server 2005 and the destination (this happens with both of them) is Excel or Access. Either way I cannot get the package which the wizard generated to run at all. This error occurs after the first table is exported. I’m running on WinXP SP2 with 2005 Developer and ALL components installed except analysis services.

    Anyone else have this problem or know the solution?

    Jeff

Answers

  • Paulino PP:The command should look like this:

    «C:\Program Files (x86)\Microsoft SQL Server\90\DTS\Binn\DTExec.exe» /FILE «C:\Documents and Settings\Keith\My Documents\Visual Studio 2005\Projects\Test SSIS\Test SSIS\bin\test_ssis.dtsx»  /MAXCONCURRENT » -1 » /CHECKPOINTING OFF /REPORTING EWCDI

    This works if the package source is «File system».  If you right click on the dtsx file and select open it should open with the Execute Package Utility, click on the last item on the left «Command Line» and you will see the full command line paramters.

    If you have saved your SSIS package to the server try saving it to a file system location and following this procedure.

    Make sure that Run64BitRuntime is set to False before you build and save the package.

Search code, repositories, users, issues, pull requests…

Provide feedback

Saved searches

Use saved searches to filter your results more quickly

Sign up

Problem

SQL Server Integration Services (SSIS) is used with Informix databases and Informix CSDK for things such as data extraction and data loading. After initial installation of oledb on a Windows environment, the oledb layer works with SSIS to pass data between SQLServer and the Informix database. During the initial setup, configuration issues may prevent connectivity.

Symptom

When the user tries an Informix connection using the OLEDB data source, an error similar to the following may be encountered:

[OLE DB Source [1]] Error: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager «database@servername» failed with error code 0xC0202009.

Cause

There is a 32 bit driver and a 64 bit driver with the same name for SSIS connection managers. If both providers are visible in the environment, the correct provider will be used. If the correct provider is not visible, you may get error code 0xC0202009 at connection time.

Diagnosing The Problem

In the properties of the SSIS project, locate the ‘Run64BitRuntime’ parameter.
Run64BitRunTime=False => will find and use the 32 bit provider.
Run64BitRunTime=True => will find and use the 64 bit provider.

Resolving The Problem

If you encounter the error code 0xC0202009 with SSIS and the Informix oledbc driver, you may be able to resolve the connection problem by setting the Run64BitRunTime to the opposite value (True=>False or False => True) before you try to connect.

[{«Product»:{«code»:»SSVT2J»,»label»:»Informix Tools»},»Business Unit»:{«code»:»BU059″,»label»:»IBM Software w\/o TPS»},»Component»:»Informix Client Software Development Kit (CSDK)»,»Platform»:[{«code»:»PF033″,»label»:»Windows»}],»Version»:»3.5;3.7″,»Edition»:»»,»Line of Business»:{«code»:»LOB10″,»label»:»Data and AI»}}]

Понравилась статья? Поделить с друзьями:
  • Код ошибки 0xc0150002
  • Код ошибки 0xc00d36c4 как исправить
  • Код ошибки 0xc00d11ba код состояния 0x00000000 как исправить
  • Код ошибки 0xc004fo74
  • Код ошибки 0xc004c060 при активации office