Honeywell xc100d ошибка e02

1. Welcome

Thank you for purchasing this Carbon Monoxide (CO) alarm.

The symbols above mean that the alarm is suitable for use in

domestic premises (including static caravan holiday homes),

caravans, motor caravans and boats.

This manual contains important safety information about the

installation and operation of the alarm. Read the manual carefully

and keep it in a safe place for future reference.

Honeywell offers three versions of its battery powered CO alarms,

with different user interfaces and lifetime:

The basic model XC70 uses indicator lights to visually signal the

state of the unit and comes with 7 years life and warranty

XC100 and XC100D both show big alarm messages in the case of

an alarm, and both come with 10 years life and warranty.

XC100D has an LCD screen to provide more information about

rising CO levels and recorded CO peak levels.

In addition, all versions have an audible alarm and a TEST/HUSH

button.

All Honeywell X-Series alarms can be wirelessly interconnected

using an optional plug-in module. This means that if one X-Series

CO or Fire Alarm triggers an alarm, all interconnected units will

give an audible alarm as well. This is especially useful, when

living in a large or multi-story dwelling. Some wireless module

information is included in this manual for completeness.

2. Description

3. About Carbon Monoxide (CO)

Operating and

Installation Instructions

X-Series Battery CO Alarms

XC70

XC100

XC100D

Warnings

Installation of a CO alarm should not be used as a substitute

for proper installation, use and maintenance of fuel burning

appliances including appropriate ventilation and exhaust

systems.

This CO alarm is designed to protect individuals from the

acute effects of carbon monoxide exposure. It will not fully

safeguard individuals with specific medical conditions. If in

doubt consult a medical practitioner.

Long exposure to low levels (>10 ppm) of CO may cause

chronic effects. If in doubt consult a medical practitioner.

4. CO Alarm Operation continued

4. CO Alarm Operation

Normal operation

The green POWER light will ash once per minute, to indicate that

your alarm is working. The screen of the XC100D will be blank.

Alarm

If a dangerous CO condition is detected the red ALARM light/

message will ash and the audible alarm will sound continuously.

XC100D will display the current CO level and a skull symbol.

If the unit is in ALARM and the gas clears, the unit will go into

Alarm Memory mode. Press the TEST/HUSH button to return to

normal operation.

If your unit is in ALARM, keep calm, and carry out the

following actions in the order given:

Open all doors and windows to increase the rate of

ventilation

Stop using all fuel-burning appliances and turn them off

where possible

If the alarm continues, then evacuate the premises. Leave

the doors and windows open, and only re-enter the building

when the alarm has stopped

Get medical help for anyone suffering the effects of

Carbon Monoxide poisoning, such as headache or nausea,

and advise that Carbon Monoxide inhalation is suspected

Telephone the gas or other fuel supplier on their emergency

number, so that the source of carbon monoxide emissions

can be identied and corrected

Do not use the fuel-burning appliances again until they

have been checked and cleared for use by a competent

person according to national regulations

Note: There may be another source of carbon monoxide

emission apart from fuel-burning appliances, for example a

large amount of tobacco smoke, town gas or emission from a

smouldering re.

1

2 3

5 6 7 8

13 14 15 16

The CO alarm will activate if it has detected a certain

concentration for a given time, as described below:

50 ppm: Alarm between 60 and 90 minutes

100 ppm: Alarm between 10 and 40 minutes

300 ppm: Alarm within 3 minutes

The CO alarm is set in accordance with the relevant European

standard to provide alarms that are determined by the

concentration and how long it has been present. This ensures

that the alarm activates when dangerous levels of CO have built

up over time and immediate action is required, and avoids false

alarms from temporary low levels of CO (e.g. from cigarette

smoke).

4

4. CO Alarm Operation continued

If the unit is in ALARM, the audible alarm can be silenced for

5 minutes by pressing the TEST/HUSH button (the red light will

continue to ash, XC100D will show the muted symbol). If a

dangerous gas level is still present after 5 minutes, the audible

alarm will sound again.

Note: The HUSH function only operates if the gas reading is less

than 350 ppm and can only be operated once

Alarm memory

CO does not leave any detectable traces, so if an alarm happens

while you are out, the memory function will keep the red light

ashing till the button is pressed or 7 days have passed.

XC100D will also show the recorded peak concentration level for

10 seconds after pressing the button.

Event logger

Honeywell’s CO alarms record a history of events, which can

be downloaded by professionals. This provides a more in depth

analysis of CO events such as detailed information on the CO

concentration of the last 7 days, and weekly maximums for the

whole operating life. Dates of alarm events are recorded.

Status Lights and Sound Display

(XC100D)

Meaning

Alarm

(Red)

Power

(Green)

Fault

(Yellow)

Ventilate

(Blue)

Sound

NORMAL

OPERATION

Normal operation

No gas present

1 ash once every minute

ALARM

*

Current CO concentration

Dangerous CO condition detected

Continuously 4 chirps and ashes

After 60 minutes, pattern is repeated once every 30 seconds

REMOTE CO or

FIRE ALARM***

Dangerous CO condition detected by

another interconnected CO alarm

CO ALARM: Continuously 4 chirps

Fire ALARM: Continuously 3 chirps

Fire detected by an interconnected

re alarm

ALARM MEMORY

Dangerous CO condition detected

whilst user was absent.

Currently, no dangerous

CO level present

1 chirp and ash once every minute

PRE-ALARM**

*

Current CO concentration and

percentage of full alarm level

A dangerous CO condition is build-

ing up.

A full CO alarm will be triggered

later, if the CO level does

not decrease

1 (2, or 3) chirps and ashes once every 30 seconds, increasing the longer CO is present

FAULT

*

The unit has reached its end of life

and must be replaced

1 chirp and ash once every minute

FAULT***

*

The wireless module is not working

correctly. Refer to the wireless

module manual for further details

3 chirps and ashes once every minute

www.homesafety.honeywell.com

www.honeywellanalytics.com

www.honeywell.com

UK customer service centre

Honeywell Analytics Ltd.

4 Stinsford Road

Nufeld Industrial Estate

Poole, Dorset BH17 0RZ

Tel: +44 (0)1202 645577

Fax: +44 (0)1202 665331

consumer@honeywell.com

Acts for and on behalf of Life Safety Distribution AG,

Javastrasse 2, 8604 Hegnau, Switzerland by

its Authorised Representative Honeywell Inc.

Please Note:

While every effort has been made to ensure

accuracy in this publication, no responsibility

can be accepted for errors or omissions.

Data may change, as well as legislation, and

you are strongly advised to obtain copies of

the most recently issued regulations, standards,

and guidelines. This publication is not intended

to form the basis of a contract.

I56-4127-001

MAN0936_Issue 2_04/14_EN

© 2014 Honeywell Analytics

Separate, indicators for

each unit state

Alarm

Power

Fault

Ventilate (pre-alarm)

TEST/HUSH button

Fault hush

Alarm hush

Test with reduced

sound level

Gas inlet

Loud sounder

output

XC70

All alarms have four status indicator lights, an audible alarm and a

TEST/HUSH button.

The green POWER light indicates that the unit is activated and

working normally.

The red ALARM light indicates that a dangerous CO condition has

been detected.

The blue VENTILATE light gives an early indication of a dangerous

CO condition.

The yellow FAULT light indicates that the unit is not working

properly.

The TEST/HUSH button is used to test the unit, or to mute an alarm

or fault signal.

Ventilate — Pre-Alarm

Dangerous CO levels may be caused by faulty appliances, which

start to produce more and more CO over time. Pre-alarms will give

an early warning of such situations even if the alarm levels are

not being reached. If these occur frequently it is recommended

to call a technician for further investigations. The pre-alarm will

start giving indications once 25% of the alarm level (time and

concentration) has been reached. For example, if 50 ppm CO is

present, the pre-alarm will start after 15-23 minutes instead of

60-90 minutes for a full alarm.

By default, this function is deactivated as it is not required to

protect you from dangerous levels of CO. The installation section

gives details of how to activate it. The pre-alarm is intended to

help the knowledgeable end-user to get an early indication of

malfunctioning appliances.

If the Pre-Alarm function is activated, and CO is detected, the blue

ventilate light will ash with a short chirp 1, 2 or 3 times every 30

seconds when 25%, 50% or 75% of the alarm level respectively

has been reached. XC100D will also indicate the percentage of the

alarm level and current CO concentration. The audible alarm can

be silenced by pressing the TEST/HUSH button (XC100D will show

the muted symbol).

Fault – end of unit life

If the unit is in FAULT the YELLOW light will ash every minute

with a short chirp. The CO alarm must not be used any more,

and should be replaced. (The only exception is a wireless module

fault, which is signalled with a triple chirp. In this case, refer to

the wireless module manual for further details). The chirps can

be silenced for 24 hours by pressing the TEST/HUSH button.

The 24 hour period can be restarted by pressing the TEST/HUSH

button twice (XC100D will show the muted symbol).

Note: The fault signal is caused by a low battery, an electronics

failure or the end of the CO sensor life. The end-of-life signal

comes from an inbuilt timer, and is given 10 years (XC100,

XC100D models) or 7 years (XC70 model) after activation.

A replace by date is also printed on the side of the unit to

facilitate an advance replacement before the end-of-life signal

is given. This date includes a 6 months shelf life, i.e. this is the

latest date the unit should be replaced. An end-of-life signal may

be given earlier.

XC100 / XC100D

Display (XC100D only)

Separate, indicators for

each unit state

Power

Fault

Ventilate (pre-alarm)

Gas inlet

Loud sounder

output

Prominent action

message:

Appears only

in alarm

(“Hidden Text”)

TEST/HUSH button

Fault hush

Alarm hush

Test with reduced

sound level

XC70 XC100 XC100D

Carbon Monoxide (CO) is an invisible, odourless gas which is

highly toxic. It is produced by the incomplete burning of fuels such

as wood, charcoal, coal, heating oil, parafn, petrol, natural gas,

propane, butane etc. and by cigarette smoke. A dangerous level of

CO can occur if an appliance is faulty or badly maintained, if a ue

is blocked or if a room is inadequately ventilated.

The poisoning effect of breathing in CO depends on the

concentration (described in parts per million, ppm) and how long

you are exposed for.

Concentration Signs and Symptoms

~ 100 ppm

Slight headache, ushing of skin

(indenite exposure)

200 – 300 ppm

Headache (5 – 6 hour exposure)

400 – 600 ppm

Severe headache, weakness, dizziness,

nausea, vomiting (4 – 5 hour exposure)

1100 – 1500 ppm

Increased pulse and breathing rate,

syncope (fainting), coma, intermittent

seizures (4 – 5 hour exposure)

5000 – 10000 ppm

Weak pulse, depressed respiration /

respiratory failure, death (1 – 2 minutes

exposure)

Source: Health Protection Agency Compendium of Chemical Hazards,

Carbon Monoxide, Version 3, 2011

75%

50%

25%

PPM

Alarm or Fault silenced

Replace unit

Remote re alarm Remote alarm triggered

by another unit

CO concentration in PPM

Number of units in a wireless

network (during conguration

with XW100 wireless module)

Full CO alarm

CO pre-alarm levels

Contact us

Contact numbers for other fuel appliances:

Oil users: Contact OFTEC on 0845 658 5080

Solid fuel users: Contact HETAS on 0800 600 000

*unless muted by pressing

the TEST/HUSH button

**only if activated during

rst time switch on

***only applicable when a

wireless interconnection

plug-in module is installed

For liquied petroleum gas (LPG),

Bulk and metered supplies; see telephone

number on the bulk storage vessel or at the meter

Cylinder supplies; see gas supplier emergency contact

details in the local telephone directory

(The Calor Gas Emergency number is 08457 444999)

GAS EMERGENCY SERVICE

TELEPHONE NUMBER

0800 111 999

Требуется руководство для вашей Honeywell XC100D Детектор угарного газа? Ниже вы можете просмотреть и загрузить бесплатно руководство в формате PDF. Кроме того, приведены часто задаваемые вопросы, рейтинг изделия и отзывы пользователей, что позволит оптимально использовать ваше изделие. Если это не то руководство, которое вы искали, – свяжитесь с нами.

Ваше устройство неисправно, и в руководстве отсутствует решение? Перейдите в Repair Café для получения бесплатных ремонтных услуг.

Руководство

Рейтинг

Сообщите нам, что вы думаете о Honeywell XC100D Детектор угарного газа, оставив оценку продукта. Хотите поделиться вашими впечатлениями от данного изделия или задать вопрос? Вы можете оставить комментарий в нижней части страницы.

Довольны ли вы данным изделием Honeywell?
Да Нет

Будьте первым, кто оценит это изделие

0 голоса

Руководство Honeywell XC100D Детектор угарного газа

Honeywell

Сигнализатор угарного газа бытовой Honeywell XC100D-RU

  • Описание
  • Детали
  • Оплата и доставка

Описание

Сигнализатор угарного газа бытовой Honeywell XC100D-RU

Рекомендуется устанавливать в каждой комнате, содержащей топливный прибор, а также в спальнях и комнатах, в которых проводится максимальное количество времени.

ХАРАКТЕРИСТИКИ:

  • литиевая батарея на 3В, срок службы до 10 лет;
  • звуковая сигнализация 90 дБ;
  • функция самопроверки каждые 60 минут;
  • ЖК дисплей с текстовым тревожным сообщением;
  • русскоязычное описание и управление;
  • температура окружающей среды -10 … +45 °C;м
  • влажность 25 – 95 % RH, без конденсации влаги;
  • прибор сигнализирует об окончании срока службы;
  • размеры 100 x 72 x 36 мм.

Интернет-магазин официального партнера Honeywell — Хонейвелл.рф предлагает конкурентные цены, техническую поддержку и осуществляет доставку продукции по России. Возможен самовывоз со складов в г. Москва и Королёв.

Оплата и доставка

Если вы хотите заказать продукцию Honeywell, отправьте заявку на info@хонейвелл.рф в свободной форме, указав артикул товара.

Оплатить товар Honeywell вы можете по реквизитам после получения счета на оплату.

Доставка осуществляется с помощью транспортных компаний по территории РФ.

  1. Сергей2403

    Регистрация:
    09.03.13
    Сообщения:


    2.225

    Благодарности:
    311

    Сергей2403

    Живу здесь

    Регистрация:
    09.03.13
    Сообщения:
    2.225
    Благодарности:
    311
    Адрес:
    Домодедово

    А что скажите про такой ?
    Угарный газ
    HONEYWELL XC100D

    Есть их же дымовой JTYJ-GD-2630/B Пожарный дымовой извещатель.

    [​IMG]

  2. Waldschnepfer

    Регистрация:
    28.11.07
    Сообщения:


    4.349

    Благодарности:
    3.055

    Waldschnepfer

    темнота некультурная

    Регистрация:
    28.11.07
    Сообщения:
    4.349
    Благодарности:
    3.055
    Адрес:
    Москва

    Ханивел, конечно, лидер в пожарных сигнализациях, но цена, работа на собственную панель и (или) четырехпроводка Вас устроят?

    Смотрите, лучше, в сторону Систем Сенсор. Часть производства в Москве, от того и дешевле. прежде, Ханивел у них датчики заказывали. Как сейчас, не знаю.

    Последнее редактирование: 03.10.17

  3. Сергей2403

    Регистрация:
    09.03.13
    Сообщения:


    2.225

    Благодарности:
    311

    Сергей2403

    Живу здесь

    Регистрация:
    09.03.13
    Сообщения:
    2.225
    Благодарности:
    311
    Адрес:
    Домодедово

    Посмотрел, цены хорошие
    Но нету датчика газа, угарного газа, нету со2,

  4. Waldschnepfer

    Регистрация:
    28.11.07
    Сообщения:


    4.349

    Благодарности:
    3.055

    Waldschnepfer

    темнота некультурная

    Регистрация:
    28.11.07
    Сообщения:
    4.349
    Благодарности:
    3.055
    Адрес:
    Москва

    В других местах искать надо. Был отечественный производитель, да на металлодетекторы для метрополитена перешел… Другой, аднака, коленкор.

  5. Сергей2403

    Регистрация:
    09.03.13
    Сообщения:


    2.225

    Благодарности:
    311

    Сергей2403

    Живу здесь

    Регистрация:
    09.03.13
    Сообщения:
    2.225
    Благодарности:
    311
    Адрес:
    Домодедово

    А каких производителей посмотреть ?

  6. Waldschnepfer

    Регистрация:
    28.11.07
    Сообщения:


    4.349

    Благодарности:
    3.055

    Waldschnepfer

    темнота некультурная

    Регистрация:
    28.11.07
    Сообщения:
    4.349
    Благодарности:
    3.055
    Адрес:
    Москва

  7. Denispnt

    Регистрация:
    21.07.11
    Сообщения:


    3.225

    Благодарности:
    1.613

    Denispnt

    Живу здесь

    Регистрация:
    21.07.11
    Сообщения:
    3.225
    Благодарности:
    1.613
    Адрес:
    Москва, Ногинск, Щелково

    На газ Яблотрон делал неплохие GS-133 (130)…

  8. Wiktar

    Регистрация:
    25.05.07
    Сообщения:


    4.530

    Благодарности:
    3.644

    Wiktar

    Живу здесь

    Регистрация:
    25.05.07
    Сообщения:
    4.530
    Благодарности:
    3.644
    Адрес:
    Москва

    Болид, вроде, начал хрень двупроводную, совмещенную (СО+дым делать («Сонет»
    ИЗВЕЩАТЕЛЬ ПОЖАРНЫЙ КОМБИНИРОВАННЫЙ ГАЗОВЫЙ ПОРОГОВЫЙ И ТЕПЛОВОЙ МАКСИМАЛЬНО-ДИФФЕРЕНЦИАЛЬНЫЙ СОНЕТ). Сам не ставил, что за зверь- надо читать.

  9. Waldschnepfer

    Регистрация:
    28.11.07
    Сообщения:


    4.349

    Благодарности:
    3.055

    Waldschnepfer

    темнота некультурная

    Регистрация:
    28.11.07
    Сообщения:
    4.349
    Благодарности:
    3.055
    Адрес:
    Москва

    Кстати, имейте в виду, что метан легче воздуха, а пропан/бутан тяжелее. Про СО не помню. Так что, соответственно Вашим реалиям, выбирайте места установки.
    Посмотрите почту.

  10. Андрей-АА

    Регистрация:
    25.11.09
    Сообщения:


    19.929

    Благодарности:
    14.230

    Андрей-АА

    Живу здесь

    Регистрация:
    25.11.09
    Сообщения:
    19.929
    Благодарности:
    14.230
    Адрес:
    Новая Москва

    Плотность СО очень близка к плотности воздуха, поэтому место установки датчика СО выбирается исходя из направления воздушного потока в месте его потенциальной установки.

  11. Denispnt

    Регистрация:
    21.07.11
    Сообщения:


    3.225

    Благодарности:
    1.613

    Denispnt

    Живу здесь

    Регистрация:
    21.07.11
    Сообщения:
    3.225
    Благодарности:
    1.613
    Адрес:
    Москва, Ногинск, Щелково

    Все газовые анализаторы имеют свои нюансы при инсталяции…

  12. Сергей2403

    Регистрация:
    09.03.13
    Сообщения:


    2.225

    Благодарности:
    311

    Сергей2403

    Живу здесь

    Регистрация:
    09.03.13
    Сообщения:
    2.225
    Благодарности:
    311
    Адрес:
    Домодедово

    Есть какие-то правило?
    Для со?
    Для природного газа?
    Часто приходилось делать включение вытяжной вентиляции по датчикам?

  13. Avkurb1970

    Регистрация:
    14.05.12
    Сообщения:


    1.524

    Благодарности:
    668

    Avkurb1970

    Живу здесь

    Регистрация:
    14.05.12
    Сообщения:
    1.524
    Благодарности:
    668
    Адрес:
    Москва

    Посмотрите MaviGard, например. Совмещенные есть в т. ч.

  14. Waldschnepfer

    Регистрация:
    28.11.07
    Сообщения:


    4.349

    Благодарности:
    3.055

    Waldschnepfer

    темнота некультурная

    Регистрация:
    28.11.07
    Сообщения:
    4.349
    Благодарности:
    3.055
    Адрес:
    Москва

    А, еще приточки и вкл. дымоудаления. :)]

  15. Denispnt

    Регистрация:
    21.07.11
    Сообщения:


    3.225

    Благодарности:
    1.613

    Denispnt

    Живу здесь

    Регистрация:
    21.07.11
    Сообщения:
    3.225
    Благодарности:
    1.613
    Адрес:
    Москва, Ногинск, Щелково

    Конечно есть, если поискать в интернете, то Вы найдете подробную инструкцию на каждый тип датчика.

Понравилась статья? Поделить с друзьями:
  • Honda fit gd1 коды ошибок
  • Honeywell dmg 972 n коды ошибок
  • Honda crv сброс ошибок
  • Honeywell cs0263c ошибка e01
  • Honeywell cs0261f ошибка e00