Closed

cawoodm opened this issue

Aug 19, 2017

· 6 comments

Closed

Constant Error 22 since updating

#255

cawoodm opened this issue

Aug 19, 2017

· 6 comments

Comments

@cawoodm

Just updated to Grbl 1.1 and keep getting error 22 with G01.

Once I manually do a G01 with F it works from then on… and then the same issue starts with G02.

So what is up? Does GRBL 1.1 really have no default feed rate? How would I set it once without doing G01?

@jahnj0584

What sender are you using

On Aug 19, 2017 9:24 AM, «Marc» ***@***.***> wrote:
Just updated to Grbl 1.1 and keep getting error 22 with G01.

Once I manually do a G01 with F it works from then on… and then the same
issue starts with G02.

So what is up? Does GRBL 1.1 really have no default feed rate? How would I
set it once without doing G01?


You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#255>, or mute the thread
<https://github.com/notifications/unsubscribe-auth/AQlzDNKaRe7F6D7PV5HadY5ZrS35yDPxks5sZtQVgaJpZM4O8UYP>
.

@gerritv

1.1 no longer has a default Feed Rate. Set one in your gcode file, or better yet use a post that does this for you.
A line at top of file with just F is enough

@PicEngraver

You can also just set a feed rate in a startup block $N=.
ex: $N1=Fxxxx, where xxxx = your desired feed rate.
This way works when you want to jog with no file loaded upon startup.
EDIT: This way works at each startup. No need to load a file to jog.

@cawoodm

Grbl Controller 3.6.1
It doesn’t allow any preamble so it’s a bit of a pain but I’ve had more success with it than UGS or Chrome’s gcode-sender.

@cawoodm

@PicEngraver

You forgot to include the «F» — F180

Hi, I’m doing a project for a hardware class and I’m doing a CNC
controller. I’m going off the tutorial here: http://www.tinkernut.com/
portfolio/hack-old-cd-roms-into-a-cnc-machine/#lightbox[9633]/13/
But instead of having x, y, and z axis I only have an x and y. When I try
to run the program I get an error 22 message. I believe I have the wrong
code and or the wrong hex file. Could someone please give me some advice
and possibly download links to the right software files and executables to
use.
Thanks.


You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#1336>, or mute the thread
<https://github.com/notifications/unsubscribe-auth/AKke-j9pGBBhNRoSe69drrErr98EyRJ5ks5tHN6mgaJpZM4RTE52>
.


Com os melhores cumprimentos,
Vinicius Silva

Error 0 – STATUS_OK

All Good, This is an error code suggesting that there is NO error

Error 1 – STATUS_EXPECTED_COMMAND_LETTER

Gcodes should start with a Letter, what ever was just sent to GRBL did not

Error 2 – STATUS_BAD_NUMBER_FORMAT

The number part of the Gcode was invalid

Error 3 – STATUS_INVALID_STATEMENT

Usualy a bad GRBL Specific $ instruction

Error 4 – STATUS_NEGATIVE_VALUE

Negative value received for an expected positive value.

Error 5 – STATUS_SETTING_DISABLED

A call to a disabled function was issued – EG you issued $H for homing but your $20 (homing enable) parameter is set to 0 (off)

Error 6 – STATUS_SETTING_STEP_PULSE_MIN

Your $0 (step pulse time) is to short, set it back to its default value, $0=10

Error 7 – STATUS_SETTING_READ_FAIL

Corrupt EEPROM values, you will need to reconfigure all your $ values as they have been reset to default – this time once you have worked them all out, make a copy!  This is a rare error.

Error 8 – STATUS_IDLE_ERROR

You have issued a command only allowed when the machine active state is Idle. Example you sent $$ while the Active state was run (job was in progress)

Error 9 – STATUS_SYSTEM_GC_LOCK

machine is locked in error of some sort, and you tried to issue a movement command. Did you forget to $X the machine? Or is it sitting on a Limit Switch?

Error 10 – STATUS_SOFT_LIMIT_ERROR

You will see this if you try to enable soft limits without also enabling homing cycle. Soft limits cannot work unless you first home the machine so it knows where it is!

Error 11 – STATUS_OVERFLOW

GRBL has a max number of charactors it will accept in one command, it received on that was too long – often happens when CAM software puts long comments in file

Error 12 – STATUS_MAX_STEP_RATE_EXCEEDED

You tried to set a Step rate that was too high, look at your $110, $111,$112 values!

Error 13 – STATUS_CHECK_DOOR

You have the safety door funtion turned on and it is showing not closed…close it

Error 14 – STATUS_LINE_LENGTH_EXCEEDED

You should not see this error and if you do you should know what it means!

Error 15 – STATUS_TRAVEL_EXCEEDED

You have got soft limits turned on and configured, and the job your trying to run is larger than you have told grbl that your machine actualy is. Either fix your soft limit values and if they are correct, look at why your cam setup is trying to use more space than you actually have.

Error 16 – STATUS_INVALID_JOG_COMMAND

Jogging command issued was not valid, possibly forgot the =… part

Error 17 – STATUS_SETTING_DISABLED_LASER

Probrably happened when you turned on $32 wthout enableing PWM – We don’t know a lot about this error – email us if you work it out and we can add it to this list

Error 20 – STATUS_GCODE_UNSUPPORTED_COMMAND

Unsupported or invalid g-code command found in block.

Error 21 – STATUS_GCODE_MODAL_GROUP_VIOLATION

Read: http://linuxcnc.org/docs/html/gcode/overview.html#_modal_groups

Error 22 – STATUS_GCODE_UNDEFINED_FEED_RATE

You cannot issue a movement if no feed rate has been set – so issue something like F1000 (feed at 1000mm/min) before sending a movement command. You will likely only see this error when bashing stuff into the command prompt and not when using a gui

Error 23 – STATUS_GCODE_COMMAND_VALUE_NOT_INTEGER

Look into the command you sent, did it include a non integer value?

Error 24 – STATUS_GCODE_AXIS_COMMAND_CONFLICT

Two G-code commands that both require the use of the XYZ axis words were detected in the block.

Error 25 – STATUS_GCODE_WORD_REPEATED

A G-code word was repeated in the block.

Error 26 – STATUS_GCODE_NO_AXIS_WORDS

A G-code command implicitly or explicitly requires XYZ axis words in the block, but none were detected.

Error 27 – STATUS_GCODE_INVALID_LINE_NUMBER

N line number value is not within the valid range of 1 – 9,999,999 – why not turn off line numbers in your CAM software

Error 28 – STATUS_GCODE_VALUE_WORD_MISSING

A G-code command was sent, but is missing some required P or L value words in the line.

Error 29 – STATUS_GCODE_UNSUPPORTED_COORD_SYS

Grbl supports six work coordinate systems G54-G59. G59.1, G59.2, and G59.3 are not supported.

Error 30 – STATUS_GCODE_G53_INVALID_MOTION_MODE

The G53 G-code command requires either a G0 seek or G1 feed motion mode to be active. A different motion was active.

Error 31 – STATUS_GCODE_AXIS_WORDS_EXIST

There are unused axis words in the block and G80 motion mode cancel is active.

Error 32 – STATUS_GCODE_NO_AXIS_WORDS_IN_PLANE

A G2 or G3 arc was commanded but there are no XYZ axis words in the selected plane to trace the arc.

Error 33 – STATUS_GCODE_INVALID_TARGET

The motion command has an invalid target. G2, G3, and G38.2 generates this error, if the arc is impossible to generate or if the probe target is the current position.

Error 34 – STATUS_GCODE_ARC_RADIUS_ERROR

A G2 or G3 arc, traced with the radius definition, had a mathematical error when computing the arc geometry. Try either breaking up the arc into semi-circles or quadrants, or redefine them with the arc offset definition.

Error 35 – STATUS_GCODE_NO_OFFSETS_IN_PLANE

A G2 or G3 arc, traced with the offset definition, is missing the IJK offset word in the selected plane to trace the arc.

Error 36 – STATUS_GCODE_UNUSED_WORDS

There are unused, leftover G-code words that aren’t used by any command in the block.

Error 37 – STATUS_GCODE_G43_DYNAMIC_AXIS_ERROR

The G43.1 dynamic tool length offset command cannot apply an offset to an axis other than its configured axis. The Grbl default axis is the Z-axis.

Error 38 – STATUS_GCODE_MAX_VALUE_EXCEEDED

You sent a number higher than expected, maybe for a tool change you tried to select tool 50000 or something?

ALARM 1 – EXEC_ALARM_HARD_LIMIT

Hard Limit Error, A limit switch was triggered, this always results in the end of your job. The only time a limit switch should be hit is during a homing cycle, at any other time it will stop the system. Either your machine went to far in one direction and hit a switch or you have electrical noise getting into your limit switch wiring. Do not restart your jhob without rehoming or resetting / confirming the machines position, it will unliely be correct still!

ALARM 2 – EXEC_ALARM_SOFT_LIMIT

Soft Limit Error, Either you or a Gcode file tried to send some axis past further than you have suggested it can in your $130, $131 ,$132 parameters

ALARM 3 – EXEC_ALARM_ABORT_CYCLE

The Estop was hit! Same as a hard limit, just a different button – look at details above for Alarm 1

ALARM 4 – EXEC_ALARM_PROBE_FAIL_INITIAL

Grbl was expecting your probe to be in a state other than that it is before starting a probing cycle – ie your tool is already touching the probe or similar

ALARM 5 – EXEC_ALARM_PROBE_FAIL_CONTACT

Z axis was sent down as far as it dared (instructed) and did not hit a switch. Instead of digging to china it assumes you forgot to put an aligator clip on or that something else is wrong and so stops.

ALARM 6 – EXEC_ALARM_HOMING_FAIL_RESET

Reset was issued during a homing cycle, or maybe falsely triggered by electrical noise in your system/environment if your estop button is connected to the Abort pin and not to the reset pin that is

ALARM 7 – EXEC_ALARM_HOMING_FAIL_DOOR

Safety door was opened during a homing cycle, or maybe falsely triggered by electrical noise in your system/environment

ALARM 8 – EXEC_ALARM_HOMING_FAIL_PULLOFF

Grbl tries to pull back of a switch and hit it a second time (slowly) during a homing cycle. Your Homing Pulloff value was not sufficient to enable the axis to move far enough away from the switch. Increase $27 to maybe 3 or 5mm – $27=5.000

ALARM 9 – EXEC_ALARM_HOMING_FAIL_APPROACH

When homing, grbl will not travel further than the values in parameters $130, $131 ,$132 while trying to locate a limit switch. So even if your soft limits are off, make sure these values are correct or larger than your machine. Homing fail. Could not find limit switch within search distance. Defined as 1.5 * max_travel on search and 5 * pulloff on locate phases.”

Hold 0 – Hold complete. Ready to resume

Hold 1 – Hold in-progress. Reset will throw an alarm

Door 0 – Door closed. Ready to resume.

Door 1 – Machine stopped. Door still ajar. Can’t resume until closed.

Door 2 – Door opened. Hold (or parking retract) in-progress. Reset will throw an alarm.

Door 3 – Door closed and resuming. Restoring from park, if applicable. Reset will throw an alarm.

LightBurn Software Forum

Loading

Alex1969

Регистрация
27.03.2019
Сообщения
24
Реакции
10
Баллы
23
Город

Минск

Имя

Александр


  • #1

Здравствуйте. Пока с Китая идет новый лазер, решил освоить данную программу. Но вот незадача, стали появляться ошибки. Описание их найти не могу. Первое, при запуске кода на выполнение выскакивает такое окно как в приложенном файле. После нажатия Ignore, процесс идет нормально. Далее, не пойму что с кнопками управления. Выставляю нулевые позиции кнопками, потом смещаю позицию гравера и при нажатии кнопки «Домой» опять вылазит ошибка — $H < error:5 S1000 < ok. Помогите, пожалуйста разобраться в данном вопросе.

  • kontrol.png

    kontrol.png

    394 KB

    · Просмотры: 315

Андрей

Андрей

Регистрация
08.05.2018
Сообщения
8 427
Реакции
8 353
Баллы
350
Адрес

Россия

Веб-сайт
www.cnc3018.ru
Город

Санкт-Петербург

Станок

CNC3018

Плата

3.2

Прошивка

1.1f


  • #2

Alex1969, скажите, а Вы в чем создаете УП ?
Какой постпроцессор используете?

Alex1969

Регистрация
27.03.2019
Сообщения
24
Реакции
10
Баллы
23
Город

Минск

Имя

Александр


  • #3

Использую Autodesk ArtCAM Premium 2018. Вчера сделал одно изображение, все получилось. И черновая и пробные на одном и том же рисунке 3 чистовых разными фрезами. А сегодня… 3 фрезы сломал. Один раз воспользовался кнопкой Z-probe и не нашел чем аварийно остановить… И после этого станок пытался рыть глубже уровня который я ему указал… Пока не отключил от компьютера. Больше ничем не пользовался. Просто не могу найти какого-либо мануала в одном месте и о том как готовить коды, назначение кнопок программы, настройка ее и ошибки как распознать.

Андрей

Андрей

Регистрация
08.05.2018
Сообщения
8 427
Реакции
8 353
Баллы
350
Адрес

Россия

Веб-сайт
www.cnc3018.ru
Город

Санкт-Петербург

Станок

CNC3018

Плата

3.2

Прошивка

1.1f


  • #4

Alex1969, здрасьте!!! :) Приехали! :)
У нас в ресурсах полно документации по поводу АртКама

А еще если использовать наш постпроцессор (тоже в ресурсах есть)
То ошибок таких не будет.

Добавьте себе вот этот

ПОСТПРОЦЕССОР >>

Вот Вам ИНСТРУКЦИЯ НА РУССКОМ ЯЗЫКЕ >>

Alex1969

Регистрация
27.03.2019
Сообщения
24
Реакции
10
Баллы
23
Город

Минск

Имя

Александр


  • #5

Спасибо большое. Многое можно узнать пообщавшись с умными людьми. Попробовал так проделать как описано в первой ссылке программа ArtCam выдала ошибку.

Ваши сообщения автоматически объединены:

Инструкцию я имел в виду к grblControl…

  • Error.png

    Error.png

    562.7 KB

    · Просмотры: 307

Alex1969

Регистрация
27.03.2019
Сообщения
24
Реакции
10
Баллы
23
Город

Минск

Имя

Александр


  • #6

И как теперь быть? Получается данный постпроцессор не принимает ArtCam?

Андрей

Андрей

Регистрация
08.05.2018
Сообщения
8 427
Реакции
8 353
Баллы
350
Адрес

Россия

Веб-сайт
www.cnc3018.ru
Город

Санкт-Петербург

Станок

CNC3018

Плата

3.2

Прошивка

1.1f


  • #7

Инструкцию я имел в виду к grblControl…

Простите, но что там инструктировать ? Там две с половиной кнопки.
Ну может как-нибудь кто-то сделает инструкцию, но я смысла большого не вижу.

И как теперь быть? Получается данный постпроцессор не принимает ArtCam?

Вы про какой постпроцессор говорите?
Я не вижу на Вашем скриншоте что там не так
И у нас работает постпроцессор нормально.
Можно пояснить что не работает и главное что делали и чего не делали?

number1

number1

Регистрация
29.12.2018
Сообщения
115
Реакции
163
Баллы
63
Имя

CNC 3018 Pro

Плата

WP 3.2A

Прошивка

Grbl 1.1f


  • #8

Alex1969, уважаемый, для начала необходимо разархивировать Custom_mm.zip :D

Alex1969

Регистрация
27.03.2019
Сообщения
24
Реакции
10
Баллы
23
Город

Минск

Имя

Александр


  • Последнее редактирование:

  • #9

Последнее редактирование:

Я по ссылке прочел фразу: «У данного файла переименуйте расширение в формат .con и скопируйте его по пути:
\Program Files\ArtCAM 2012\postp\»
Так и выполнил. Про разархивацию ни слова. Я думал просто форум не позволяет выкладывать файлы с подобными расширениями. Хорошо, попробую.

Простите, но что там инструктировать ? Там две с половиной кнопки.
Ну может как-нибудь кто-то сделает инструкцию, но я смысла большого не вижу.

Да, но просто у меня они не работают адекватно, кроме обнуления позиции. Не работает, например, кнопка «Домой» и некоторые другие. Я не знаю почему, вот и хотел разобраться.

Ваши сообщения автоматически объединены:

В общем там нужно заменить фразу «У данного файла переименуйте расширение в формат » в «Распакуйте данный архив и полученный файл…». Все получилось. Спасибо!
Вопрос по кнопкам с изображением человечка, домика, ресет и унлок. Смысл понимаю, но ничего не происходит при их нажатии.

Дым506

Регистрация
16.12.2019
Сообщения
112
Реакции
63
Баллы
48
Город

Россия


  • Последнее редактирование:

  • #10

Последнее редактирование:

$H<ERROR:5 тоже такая ошибка

вот , постпроцессор исправит ?

Ваши сообщения автоматически объединены:

установил постпроцессор не помогло , нажимаю кнопку дом и опять таже ошибка

  • Снимок.PNG

    Снимок.PNG

    2.7 KB

    · Просмотры: 141

extrimus

extrimus

Регистрация
29.03.2019
Сообщения
5 905
Реакции
5 267
Баллы
250
Возраст
57
Адрес

Россия

Город

Иваново

Имя

Андрей

Плата

Woodpecker 3.2

Прошивка

GBRL 1.1f


  • Последнее редактирование:

  • #11

Последнее редактирование:

$H<ERROR:5 тоже такая ошибка

вот , постпроцессор исправит ?

Ваши сообщения автоматически объединены:

установил постпроцессор не помогло , нажимаю кнопку дом и опять таже ошибка

Постпроцессор в поиске дома никакой роли не играет. Концевики-то у вас стоят? Параметр $22 активирован?

Дым506

Регистрация
16.12.2019
Сообщения
112
Реакции
63
Баллы
48
Город

Россия


  • #12

концевиков нет , $22=0 ,

Ваши сообщения автоматически объединены:

вообще для чего эта кнопка дом , извените конечно я есчо в чпу совсем балбес

extrimus

extrimus

Регистрация
29.03.2019
Сообщения
5 905
Реакции
5 267
Баллы
250
Возраст
57
Адрес

Россия

Город

Иваново

Имя

Андрей

Плата

Woodpecker 3.2

Прошивка

GBRL 1.1f


  • #13

Ну и что вы тогда хотите? Поиск дома работает только при наличии концевиков.

extrimus

extrimus

Регистрация
29.03.2019
Сообщения
5 905
Реакции
5 267
Баллы
250
Возраст
57
Адрес

Россия

Город

Иваново

Имя

Андрей

Плата

Woodpecker 3.2

Прошивка

GBRL 1.1f


  • #14

вообще для чего эта кнопка дом , извените конечно я есчо в чпу совсем балбес

Чтоб станок «знал» свои начальные координаты.
Вам бы, прежде чем включать станок, азы для начала изучить: https://cnc3018.ru/ewr-carta/

denbar

Регистрация
29.02.2020
Сообщения
28
Реакции
10
Баллы
23
Город

Волгоград

Имя

Денис


  • #15

Кто подскажет что за ошибка error 1 , а после сразу error 22