  • On Server 2008 R2 Enterprise, I keep getting event id 1110 errors from Group Policy, indicating Windows cannot tell if the user and computer are in the same forest. I can’t find any obvious issue on the domain controllers. I can ping the DCs and nltest /server:<dcname> against the DCs returns no error. When I have a  user execute gpresult /H GPOResult.html as suggested in Technet, it hangs. Reboot fixes the issue, but I need to find a better solution for the production environment. I also notice that if I go to add a user or group to the local Administrators group, it does not display the domain as a location from which to add users, just the local computer and  «Entire Directory». Interestingly enough, if I select «Entire Directory» and enter a samid, it resolves it fine. Can someone point me in the right direction to resolve this issue?

    Thanks

How to fix Gpresult error message

When i type Gpresult in cmd i the following error message:
c:\> Gpresult
ERROR Invalid Namespace
how to fix that?

July 11th, 2012 4:14pm


Hi,
check that your DNS is configured properly «use NSLOOKUP» also verify that you don’t have issue in your network connection and check the event log if there is an error related
to this problem .Oussama Oueslati | System Engineer | vNext Consulting

July 11th, 2012 9:39pm


How to use nslookup ?
what are the things i should look at the result in the nslookup command?
C:\>nslookup
*** Can’t find server name for address 192.168.2.110: Non-existent domain
*** Default servers are not available
Default Server: UnKnown
Address: 192.168.2.110

July 12th, 2012 12:18am


How to use nslookup?
What are the things i should look at the result of the nslookup command in cmd?

C:\>nslookup
*** Can’t find server name for address 192.168.2.110: Non-existent domain
*** Default servers are not available
Default Server: UnKnown
Address: 192.168.2.110

July 12th, 2012 12:22am


Hello,
please post an unedited ipconfig /all from the DC/DNS server and the workstation with the error.
Is any GPO configured that may disable the processing on the domain machines?Best regards
Meinolf Weber
MVP, MCP, MCTS
Microsoft MVP — Directory Services
My Blog: http://msmvps.com/blogs/mweber/

Disclaimer: This posting is provided AS IS with no warranties or guarantees and confers no rights.

July 12th, 2012 3:04am


From NSLOOKUP commandline it is clear that your DNS is misconfigured.
Please add the reverse record of your DNS server in Reverse lookup zone.
Regarding NSLOOKUp,
It is a tool which is used to check the DNS settings .
Refer below link to understand NSLOOKUP command line
http://www.windowsnetworking.com/articles_tutorials/using-nslookup-dns-server-diagnosis.html
http://technet.microsoft.com/en-us/library/aa997324(v=exchg.65).aspx
Regards,
_Prashant_MCSA|MCITP SA|Microsoft Exchange 2003 Blog — http://prashant1987.wordpress.com Disclaimer: This posting is provided AS-IS with no warranties/guarantees and confers no rights.

July 12th, 2012 3:43am


if you are using dynamic addressing, configure your DHCP server/service to alocate for DNS ip address the IP for your Domain Controller/DNS.
Please post an ipconfig /all from domain controller/DNS as requested.MCTS — Please remember to click Mark as Answer on the post that helps you, and to click Unmark as Answer if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread.
http://mariusene.wordpress.com/

July 12th, 2012 4:48am


I don’t think so, i didn’t make any changes after installing windows xp pro.
When i typed nslookup in cmd i receive this error message:

C:\>nslookup
*** Can’t find server name for address 192.168.2.110: Non-existent domain
*** Default servers are not available
Default Server: UnKnown
Address: 192.168.2.110

July 13th, 2012 10:47pm


Actually i did this command from windows xp.

July 13th, 2012 10:48pm


Hi,
Please refer KB article
Hope this help you.
Thanks.

Mohammed Imtiyaz Ali

July 14th, 2012 1:30am


When i type Gpresult in cmd i the following error message:
c:\> Gpresult
ERROR Invalid Namespace
how to fix that?

Seems it is a WMI issue, have you configured any script using GPO?. I suggest you try to
repair XP machine WMI once and check for the difference.

Regards, Ravikumar P

July 14th, 2012 9:19am


Hi Ravikumar
have you configured any script using GPO?
No there’s no setting changed to the group policy object.
After registered XP machine WMI?
C:\>gpresult
ERROR: The dependency service or group failed to start.
Can’t start WMI in service.msc?
—————————
Services
—————————
Could not start the Windows Management Instrumentation service on Local Computer.
Error 1068: The dependency service or group failed to start.
—————————
OK
—————————

There’s no Dependency tab none of the services inside the services.msc.

July 14th, 2012 1:20pm


I still couldn’t figure out how to fix the problem after finished too read the links that you provided, but thanks anyway hey.

July 14th, 2012 1:28pm


WMI service will start automatically when you reboot XP machine. So do this try once and check it again.Regards, Ravikumar P

July 15th, 2012 6:19pm


Hi,
When try to access to «services.msc» is there any error that’s showing, I suggest that you take look at this link it can help you:
http://www.completepcpedia.com/fix_error_1075_dependency_service_marked_deletion.html

Oussama Oueslati | System Engineer | vNext Consulting

July 16th, 2012 4:51am


When try to access to «services.msc» is there any error that’s showing, I suggest that you take look at this link it can help you

:

I can access to services.msc without error message but if i want to start the WMI service the following error message:
Before register windows xp WMI
c:\> Gpresult
ERROR Invalid Namespace

Ater register windows xp WMI
c\>gpresult
ERROR: The dependency service or group failed to start.

I also have tried the link that you provided is not working too.

July 18th, 2012 11:58pm


Ensure the Namespace in question actually exist and functional.

  1. Go to start-run and type in wmimgmt.msc.
  2. Right click on Local Wmi Control (Local)and select properties.
  3. On the general tab, if there is any failures noted on that box, that indicates a core WMI issue and most likely with the Cimv2 namespace.

How do I enable RSoP?

In this article

  1. On the Start screen, type MMC. The Microsoft Management Console opens.
  2. Click File, and then click Add/Remove Snap-in.
  3. In the Available snap-ins window, go down to the Resultant Set of Policy snap-in option, click Add, and then click OK. You’re now ready to use the RSoP snap-in from the console.

How do I open RSoP MSC?

Open the command line, type rsop. msc and hit enter. Rsop will run and generate a report for the user and computer policy settings. Now that RSoP has run its time to review the policy settings.

How do I open Gpresult in HTML?

gpresult Command: To see the Gpresult commands, go to the command prompt and type the command: “gpresult /?” The output shown below displays the description and parameter list of the resultant set of policies (RSoP) for a target user and the computer.

How do I fix invalid namespace error?

Troubleshoot errors on client systems Patch Manager usually returns the Invalid namespace error for managed clients when they do not have the requisite WMI Providers installed. To begin, disable the anti-virus software on the client. If this does not resolve the issue, install the WMI Providers on the client.

How do I fix WMI?

To perform a rebuild of the WMI repository, please do the following:

  1. Disable and stop the winmgmt service.
  2. Remove or rename C:\Windows\System32\wbem\repository.
  3. Enable and start the winmgmt service.
  4. Open Command Prompt as Administrator.
  5. Run the following commands:

How do you test if a GPO is working?

Press the Windows key + R to open the Run box. Type rsop. msc and press Enter. The Resultant Set of Policy tool will start scanning your system for applied group policies.

How do I fix a GPO problem?

Open gpmc and verify the Group policy which is in question.

  1. Make sure the group policy has all the settings that you are looking for, and it is correctly linked.
  2. Verify the gpresult that you have captured and look for the GPO that we are having issues with, it will give the error why the GPO is not getting applied.

How do I open the Group Policy Editor?

Press Windows+R on your keyboard to open the “Run” window, type gpedit. msc , and then hit Enter or click “OK.”

How do I check if Group Policy is applied?

The easiest way to see which Group Policy settings have been applied to your machine or user account is to use the Resultant Set of Policy Management Console. To open it, press the Win + R keyboard combination to bring up a run box. Type rsop. msc into the run box and then hit enter.

What is invalid namespace error?

Troubleshoot “Invalid Namespace” errors from the Patch Manager server or managed clients. This error message indicates that the WMI Providers are not accessible by the server or not present on the clients.

What is the use of namespace?

Explanation: Namespace allows you to group class, objects, and functions. It is used to divide the global scope into the sub-scopes.

Is there a way to run gpresult with invalid pointer?

Able to run GPResult /R >> .txt Able to run GPResult /V >> .txt Able to run GPResult /Z >> .txt I created a new GPO to replace one that is not able to be backed up but is working and am having the same problem with the invalid pointer. I can run GPResult /X and it doesn’t error out but the file is not easy to read.

What does invalid namespace mean in patch manager?

This error message indicates that the WMI Providers are not accessible by the server or not present on the clients. Provide a short description of the article. The title appears in the article and in search results. Invalid namespace errors from either the Patch Manager server or managed clients.

What to do if WMI says namespace is invalid?

You may also run sfc /scannow to check if there are any corrupted or missing system files. Besides, if you don’t want to troubleshoot the issue, reinstall is a quick way to repair. Please remember to mark the replies as answers if they help and unmark them if they provide no help.

How to fix invalid namespace in Spiceworks?

Get answers from your peers along with millions of IT pros who visit Spiceworks. I have tried the WMI reset, but still cannot get past the invalid namespace error. I have seen some sites mention running CIMInstance first but I am unsure of the actual command as a whole.

I have a Windows 2008R2 domain with several hundred computers and users. I have had some problems with certain users that I originally thought was a problem with the computer network adapter. They are not getting group policy assignments and when I run GPRESULT, I get the message;

————————————-———-———-———-———-———-———-——

INFO: The user «Domain Name\User Name» does not have RSOP data. If I try to run RSOP.msc while logged in as this user, I get the following;

Group Policy Error
RSoP data is invalid. Likely causes are, data is corrupt, data has been deleted or data has never been created.

Details: Invalid namespace
————————————-———-———-———-———-———-———-——-

I can log in as my user account, which has domain admin rights, and GPRESULT and RSoP.msc both work.

If I log in to another computer using the problem user name, I get the same errors as listed above when I run GPRESULT and RSoP.msc

This was not always the case with the user; it all used to work correctly.

Obviously, the issue is with the user account in the domain but I am not sure where to start.

I don’t want to just delete and recreate the user unless that is the last result.

Any ideas?

Thanks,

Dave

Продолжая тему борьбы с неполадками в работе Windows Management Instrumentation (WMI) рассмотрим ситуацию когда проблемный сервер «ни под каким соусом» не хочет возвращать значения из пространства имён WMI, что чревато всякими неприятностями, например при просмотре свойств системы не отображается информация о процессоре и оперативной памяти…

image

При попытке открыть свойства WMI Control в оснастке Computer Management можно обнаружить ошибку инициализации основных системных WMI классов.

Failed to initialize all required WMI classes.
Win32_Processor. WMI: Invalid namespace   
Win32_WMISetting. WMI: Invalid namespace 
Win32_OperationSystem. WMI: Invalid namespace

image

Методы исправления ситуации

Метод #1

Пробуем перезапустить службу WMI и если проблема не устраняется запускаем проверку согласованности базы данных WMI с запуском её перестроения при обнаружении несогласованности.

net stop Winmgmt & net start Winmgmt
winmgmt /salvagerepository

Метод #2

Метод с перекомпиляцией mof/mfl файлов имеющихся в каталоге %windir%\system32\wbem. Помогал неоднократно. Запускаем на проблемном сервере командную строку с правами Администратора и выполняем последовательно команды:

cd /d C:\WINDOWS\system32\wbem
for /f %x in ('dir /b *.mof ^| findstr /v /i uninstall') do mofcomp %x

Метод #3

Более жёсткий метод. Можно попробовать его если первый и второй методы не помогают. Останавливаем службу WMI, выполняем перерегистрацию всех библиотек dll в каталоге %windir%\system32\wbem, переименовываем каталог %windir%\system32\wbem\Repository и снова запускаем службу WMI, после чего WMI Repository будет сгенерирован заново.

net stop Winmgmt 
cd /d C:\WINDOWS\system32\wbem 
for /f %s in ('dir /b *.dll') do regsvr32 /s %s 
move C:\WINDOWS\system32\wbem\Repository Repository_BAD
net start Winmgmt

После этого, если проблемы с WMI устранены, можно удалить каталог Repository_BAD а также при необходимости выполнить перекомпиляцию файлов *.mof относящихся к отдельным приложениям таким как например SQL Server.

Дополнительные источники информации:

TechNet Forums — failed to initialize all required wmi classes on Primary server
TechNet Forums — WMI becomes corrupt on FIM Service/Sync server

Понравилась статья? Поделить с друзьями:
  • Gpo ошибка 1130
  • Gpg4usb ошибка расшифровки no data
  • Gpedit msc выдает ошибку
  • Gpedit msc windows 10 ошибка групповой политики
  • Gparted проверка диска на ошибки