  • Code 7900
  • Code: 7900
  • Description: Drum unit EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
  • Causes: Defective connector cable or poor contact in the connector. Defective drum unit.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and relay-L PWB (YC3) Relay-L PWB and engine PWB (YC15)
    Defective drum unit. Replace the drum unit.

Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.

В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.

Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.

Код ошибки Описание ошибки Причина ошибки
0100 Backup memory device error Defective flash memory. Defective main PWB.
0120 MAC address data error
For data in which the MAC address is invalid.
Defective flash memory. Defective engine PWB.
0130 Backup memory read/write error Defective flash memory. Defective control PWB.
0140 Backup memory data error Defective flash memory. Defective control PWB.
0150 Control PWB EEPROM error
Detecting control PWB EEPROM (U17) communication error.
Improper installation control PWB EEPROM (U17). Defective control PWB. Data damage of control PWB EEPROM (U17).
0170 Billing counting error Defective control PWB. Data damage of control PWB EEPROM (U17).
0190 Backup memory device error (engine PWB) Defective engine PWB.
0800 Image processing error
JAM010x is detected twice.
Defective main PWB.B.
0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
Defective control PWB. The battery is disconnected from the control PWB.
1010 Lift motor error
During driving the lift motor, a motor overcurrent signal is detected for 5 s. This error is detected five times successively.
Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB or connect-R PWB.
1020 PF lift motor 1 error (paper feeder)
After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
1030 PF lift motor 2 error (paper feeder)
After cassette 3 is inserted, PF lift sensor 2 does not turn on. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
1040 PF lift motor 3 error (paper feeder)
After cassette 4 is inserted, PF lift sensor 3 does not turn on. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
1050 PF lift motor 4 error (paper feeder)
After cassette 5 is inserted, PF lift sensor 4 does not turn on. This error is detected four times successively.
Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
1140 BPF lift motor upward error (Bulk paper feeder)
BPF lift maximum sensor does not turn on. The lock signal of the motor is detected continuously three times.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the motor. Defective BPF lift motor. Defective BPF main PWB.
1150 BPF lift motor downward error (Bulk paper feeder)
BPF lift minimum sensor does not turn on. The lock signal of the motor is detected continuously three times.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the motor. Defective BPF lift motor. Defective BPF main PWB.
1800 Paper feeder 1 communication error
A communication error is detected 10 times in succession.
Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective engine PWB. Defective PF main PWB.
1810 Paper feeder 2 communication error
A communication error is detected 10 times in succession.
Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective PF main PWB.
1820 Paper feeder 3 communication error
A communication error is detected 10 times in succession.
Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective PF main PWB.
1830 Paper feeder 4 communication error
A communication error is detected 10 times in succession.
Improper installation paper feeder. Defective connector cable or poor contact in the connector. Defective PF main PWB.
1900 Paper feeder 1/BPF paper feeder EEPROM error
When writing the data, the write data and the read data is not in agreement.
Defective PF main PWB. Device damage of EEPROM.
1910 Paper feeder 2 EEPROM error
When writing the data, the write data and the read data is not in agreement.
Defective PF main PWB. Device damage of EEPROM.
1920 Paper feeder 3 EEPROM error
When writing the data, the write data and the read data is not in agreement.
Defective PF main PWB. Device damage of EEPROM.
1930 Paper feeder 4 EEPROM error
When writing the data, the write data and the read data is not in agreement.
Defective PF main PWB. Device damage of EEPROM.
2000 Main motor error
The main motor ready input is not given for 2 s during the main motor is ON.
Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion. Defective drive transmission system of the main motor. Defective main motor. Defective control PWB.
2010 Main motor steady-state error
Stable OFF is detected for 2 s continuously after main motor stabilized.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the main motor. Defective main motor. Defective engine PWB.
2200 Drum motor steady-state error
The drum motor ready input is not given for 2 s during the drum motor is ON.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB.
2210 Drum motor steady-state error (60/50/45 ppm model only)
Stable OFF is detected for 2 s continuously after drum motor stabilized.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the drum motor. Defective drum motor. Defective engine PWB.
2330 Fuser pressure release motor error (Over-current) (60/50/45 ppm model only)
The over-current detection signal of the motor is detected continuously twenty times.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective PWB.
2340 Fuser pressure release motor error (Timeout) (60/50/45 ppm model only)
The position detection sensor is not detected continuously for 30 s.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective PWB.
2600 PF drive motor 1 error (paper feeder 1)
When the PF drive motor is driven, error signal is detected continuously for 2 s.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF drive motor. Defective PF drive motor. Defective PF main PWB.
2610 PF drive motor 2 error (paper feeder 2)
When the PF drive motor is driven, error signal is detected continuously for 2 s.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF drive motor. Defective PF drive motor. Defective PF main PWB.
2620 PF drive motor 3 error (paper feeder 3)
When the PF drive motor is driven, error signal is detected continuously for 2 s.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF drive motor. Defective PF drive motor. Defective PF main PWB.
2630 PF drive motor 4 error (paper feeder 4)
When the PF drive motor is driven, error signal is detected continuously for 2 s.
Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF drive motor. Defective PF drive motor. Defective PF main PWB.
4000 Polygon motor (laser scanner unit) error
The polygon motor ready input is not given for 6 s during the polygon motor is ON.
Defective harness between polygon motor and control PWB (YC10), or improper connector insertion. Defective laser scanner unit. Defective control PWB.
4200 BD error (laser scanner unit) error BD sensor does not detect laser beam due to condensation on the polygon mirror. Defective laser scanner unit. Defective control PWB.
5100 Main charger high-voltage error
Five pages have been printed with the main charger output short-circuited.
Drum unit installed incorrectly. Engine PWB installed incorrectly. Defective engine PWB.
6000 Broken fuser heater wire
The temperature does not reach 100°C/212°F after the fuser heater has been turned on continuously for 30 s. The temperature does not rise by 1°C/1.8°F after the fuser heater lamp has been turned on continuously for 15 s during warm-up or at standby.(Only when the detection temperature is less than 200°C.)
Defective connector cable or poor contact in the connector. Fuser thermostat triggered. Broken fuser heater wire.
6020 Abnormally high fuser thermistor temperature
Fuser thermistor detects abnormally temperature.
Shorted fuser thermistor. Defective control PWB.
6030 Broken fuser thermistor wire
Input from fuser thermistor is 0 (A/D value).
Poor contact in the fuser thermistor connector terminals. Broken fuser thermistor wire. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater lamp installed incorrectly. Broken fuser heater lamp wire.
6120 Abnormally high fuser thermistor 1 temperature
(60/50/45 ppm model) The detection temperature of fuser thermistor 1 is higher than 245°C/473°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 195°C/383°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. (40 ppm model) The detection temperature of fuser thermistor 1 is higher than 250°C/482°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 170°C/338°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less.
Deformed connector pin. Defective triac. Shorted fuser thermistor. Defective engine PWB.
6130 Broken fuser thermistor 1 wire
A/D value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up.
Defective connector cable or poor contact in the connector. Deformed connector pin. Defective triac.or pin. Defective fuser thermistor. Defective engine PWB.
6400 Zero cross signal error
The zero cross signal does not reach the control PWB for specified time.
Defective harness between high voltage PWB (YC202) and control PWB (YC23), or improper connector insertion. Defective connection between power source PWB (YC103) and high voltage PWB (YC201). Defective power source PWB. Defective control PWB.
7000 Toner motor lock error
During driving the toner motor, a motor overcurrent signal is detected for 5 s.
Lump of toner inside toner container. Defective drive transmission system of the toner motor. Defective toner motor. Defective engine PWB.
7100 Toner sensor error
Sensor output value of 930 or more continuously for 5 s.
Defective connector cable or poor contact in the connector. Defective toner sensor. Defective engine PWB.
7400 Developer unit non-installing error
Sensor output value of 31 or less continuously for 5 s.r.
Defective connector cable or poor contact in the connector. Defective toner sensor. Defective engine PWB.
7410 Drum unit non- installing error The drum unit is not installed or not installed properly. The drum PWB EEPROM does not communicate normally. The drum unit is not installed. Defective connector cable or poor contact in the connector. Defective drum PWB EEPROM. Defective engine PWB.
7800 Broken external thermistor wire
The average of thermistor output value of 1016 or more continuously for 160 ms. The average of thermistor output value of 930 or more continuously for 5 s.
Defective connector cable or poor contact in the connector. Defective temperature sensor.
7810 Short-circuited external thermistor wire
The average of thermistor output value of 31 or less continuously for 5 s.
Defective connector cable or poor contact in the connector. Defective temperature sensor.
7900 Drum unit EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Defective connector cable or poor contact in the connector. Defective drum unit.
F000 Main PWB — operation panel PWB communication error Defective main PWB. Defective operation panel PWB.
F010 Main PWB checksum error Defective main PWB.
F020 Main PWB RAM checksum error Defective main memory (RAM) on the main PWB. Defective expanded memory (DIMM).
F040 Main PWB — engine PWB communication error Defective main PWB. Defective engine PWB.
F041 Main PWB — scanner communication error Defective main PWB.
F050 Engine ROM checksum error Defective engine PWB.
F051 Scan engine ROM checksum error Defective engine PWB.

Содержание

  1. Причины и типы горящей кнопки «Внимание» на принтере Kyocera
  2. Ошибки картриджей
  3. Код C7990
  4. Замятие бумаги
  5. Другие неисправности
  6. Сброс ошибок у принтеров Kyocera своими руками

Для начала необходимо разобраться, какие варианты свечения красной кнопки на принтере Kyocera существуют. В большинстве случаев именно определение характера свечения позволяет устранить проблему, не делая ничего лишнего. Каждый из этих типов связан с конкретной природой проблемы, которую мы рассмотрим ниже.

Проверка индикатора мерцания для решения проблемы с кнопкой

  1. Медленное мигание лампочки. Если свет тускнеет, а затем ярко вспыхивает и медленно меняет яркость, это может быть одной из двух проблем печати. Первый вызван тем, что закончилась бумага, которую следует проверить и при необходимости вставить заново. Если бумага уже вставлена, но принтер ее не видит, попробуйте слегка отрегулировать ее и отрегулировать ручки, затянув или ослабив их. Вторая причина заключается в том, что тонер в картридже заканчивается, и чтобы проверить это, просто визуально проверьте качество печати готового документа и вспомните, когда принтер заправлялся в последний раз.
  2. Быстрое мигание света. Иногда свет имеет другой коэффициент горения, довольно часто мигая. Это может означать, что был обнаружен неоригинальный картридж, не совместимый с данным устройством. Другой причиной этого явления является переполнение памяти принтера, вызванное попыткой распечатать слишком большой документ. Реже быстрое мигание вызвано перегруженным или засоренным лотком для бумаги, поэтому мы рекомендуем немедленно проверить это и при необходимости устранить неисправность.
  3. Непрерывное мигание индикаторной лампочки. Если возникают ошибки печати и кнопка горит постоянно, стоит проверить, закрыта ли крышка принтера и есть ли тонер в кассете. Вы можете устранить эти неисправности самостоятельно, поэтому трудностей возникнуть не должно. Более редкой и серьезной проблемой является выход из строя барабана формирования изображения. В таких случаях следует обратиться в сервисный центр для дальнейшей диагностики и ремонта.

Теперь, когда вы знаете, какой мигающий рисунок отвечает за те или иные проблемы, вы сможете провести диагностику устройства и понять, какие действия необходимо предпринять. Тем, кто недавно заправил чернильный картридж и столкнулся с этой проблемой, следует перезагрузить принтер, как описано ниже. Всем, кому не удалось самостоятельно устранить ошибку, рекомендуется выполнить следующие шаги, а затем перейти к последнему совету, если и он окажется безуспешным.

Ошибки картриджей

Все современные принтеры страдают от ошибок картриджей. В большинстве случаев они возникают после отгрузки устройства. Решение заключается в извлечении и повторной установке картриджа. Сделать это можно следующим образом (на примере многофункционального устройства Kyocera FS-1040):

  • Выключите принтер.
  • На передней панели принтера находится откидная крышка. Откройте откидную крышку.
  • Под откидной крышкой с левой стороны находится картридж. Извлеките картридж.
  • Чтобы подстраховаться, проверьте переднюю часть картриджа. Если на контактах есть грязь, удалите ее мягкой безворсовой тканью. Для засохших чернил смочите салфетку в воде и протрите ею контакты.
  • Замените чернильный картридж, плотно задвинув его до щелчка.
  • Включите принтер и подождите около 5-10 секунд, пока картридж инициализируется.

Если проблема была связана с картриджем, эта процедура должна помочь ее решить.

Код C7990

Этот номер ошибки в таких моделях, как FS 1020MFP, указывает на то, что бункер для тонера переполнен.

Ошибка C7990

Ошибка C7990

Возможны три причины ошибки C7990:

-плата PWB неисправна;
-Датчик чернил неисправен;
Неисправен блок барабана; — Картридж переполнен — Рекомендуется заменить блок барабана.

Узел барабана изображения

Блок барабана формирования изображения

В первых двух случаях обратитесь в сервисный центр.

В третьем случае появляется код C7990, если срок службы барабана изображения не закончился, барабан изображения можно очистить от чернил. Процедура выполняется следующим образом:

1.Откройте переднюю крышку и извлеките блок проявителя.
2.Извлеките барабан с изображением.
3.Осторожно откройте крышку резервуара и удалите чернила.
4.Соберите машину в обратном порядке.

Как видите, ошибку C7990 в принтере Kyocera легко устранить самостоятельно, и к специалисту нужно обращаться только в том случае, если платы действительно неисправны.

Основные ошибки в принтерах Kyocera

Замятие бумаги

Застревание бумаги внутри принтера — распространенная проблема принтеров. Устройства Kyocera не являются исключением. Механизм подачи бумаги состоит из нескольких вращающихся роликов. Если любой из них застрянет, печать не будет выполнена. Если произошло замятие бумаги, на передней панели принтера также появится соответствующее сообщение.

В самых оптимистичных случаях нет необходимости разбирать принтер для извлечения бумаги. Чаще всего он заклинивает прямо на входе. Однако если замятие бумаги произошло внутри принтера, его необходимо удалить.

Другие неисправности

Также могут возникнуть следующие коды:

-C-F040. Выключите и снова включите принтер, нажав кнопку питания.
-J-0511 Код указывает на замятие бумаги под задней крышкой. В инструкциях описано, как удалить бумагу в соответствующем разделе.
-PF. Принтер показывает, что листы были добавлены во входной лоток.

Основные ошибки принтера Kyocera

Как видите, японские принтеры Kyocera редко ломаются. Чаще всего ошибки возникают из-за неправильного или невнимательного обращения. Вы можете починить их самостоятельно, но если вы не уверены, лучше обратиться к профессионалу.

Сброс ошибок на принтерах Kyocera следует понимать как набор шагов, которые потенциально может выполнить опытный пользователь для восстановления работоспособности печатающих устройств, не прибегая к услугам сервиса.

Ошибка #

Причина

Решение

E-0001

В принтер был установлен совместимый картридж или поврежден чип расходного материала. Эта проблема может быть решена несколькими способами:

1. установка оригинального картриджа;

2. замена неисправного чипа;

3. перепрошивка принтера — после этого любой картридж может быть установлен в принтер неограниченное количество раз;

4. сброс ошибки — Нажмите кнопки «Режим» и «Сброс» на несколько секунд.

E-0002

Регион используемого картриджа не соответствует принтеру. Эта проблема может быть решена несколькими способами:

1. установите правильный картридж для региона принтера;

2. Замените микросхему;

3) Обновите микропрограмму принтера.

E-0003

Память в принтере заполнена. Распечатайте документы, которые уже были отсканированы, или сбросьте операцию с помощью соответствующей кнопки.

E-0007

Тонер-картридж закончился. Замените новый оригинальный тонер-картридж, совместимый тонер-картридж или перезарядите картридж.

E-0008

Одна из крышек принтера не закрыта. Закройте переднюю и заднюю крышки принтера, звучно щелкнув.

E-0009

Лоток для печати заполнен. Извлеките отпечатанные листы бумаги, затем нажмите кнопку Старт, чтобы возобновить печать.

E-0012

Память принтера заполнена. Уменьшите разрешение печати до 600 точек на дюйм.

E-0014

Установлен размер бумаги, который не поддерживается принтером. Замените бумагу на совместимую по размеру.

Иногда функциональность принтера может быть ограничена на уровне программного обеспечения.

Для расширения диапазона размеров рекомендуется обновить программное обеспечение принтера.

E-0015

1 Принтер не имеет источника питания.

2. сетевой кабель не подключен.

3. на персональном компьютере отсутствует драйвер.

Проверьте целостность сетевого кабеля.

Включите принтер.

При необходимости установите драйвер.

E-0018

Выбранный файл отсутствует в очереди печати. Сбросьте операцию, нажав кнопку «Сброс». Затем выберите новый файл и продолжите печать.

E-0019

Формат печати не поддерживается принтером. Сбросьте действие, нажав кнопку «Сброс».

J-0511

Бумага замята. Осторожно извлеките оставшуюся бумагу из корпуса принтера.

ПФ

Во входном лотке нет бумаги. Вставьте бумагу во входной лоток и возобновите печать, нажав кнопку Старт.

Источники

  • https://Lumpics.ru/kyocera-printer-does-not-print-attention-button-is-on/
  • https://ru.NoDevice.com/articles/printers/does-not-print-a-kyocera-printer
  • https://www.dvenashka.ru/2021/11/kody-oshibok-printerov-kyocera-i-ih-sbros.html
  • https://computermaker.info/ecosys-fs-1020mfp-oshibka-e7.html
  • http://printergid.ru/neispravnosti/oshibki-kyocera
  • https://moscowtoner.ru/kody-oshibok-u-printerov-kyocera/

Правила форума
Картинки и фотографии (если они нужны в сообщении) надо загружать только как вложения к своему сообщению (через кнопку Добавить файлы). Тогда картинки будут автоматически отображаться в сообщении.

Yuzorg98

Сообщения: 29
Стаж: 1 год 1 месяц

Kyocera Ecosys P3150dn

Сообщение

Yuzorg98 »

В общем начал выдавать ошибку как на фото
Включается,пишет замятие, вытаскиваю блок фотоузла ( он нормальный, считай новый) вместе с катриком, закрываю принтер и вылезает она.
Ставил с другого принтера фотоузел с катриком, та же ситуация.
Внутри ничего нет, никакой бумаги.
Печка вроде нормальная, только вал прижима малость скукожился.
В чём может быть проблема?
Перерыл весь инет и форумы, ничего не нашёл.
Изображение

Yuzorg98

Сообщения: 29
Стаж: 1 год 1 месяц

Kyocera Ecosys P3150dn

Сообщение

Yuzorg98 »

стронций писал(а): ↑03 апр 2023, 15:44
Ну если дело не в переполненном бункере с отработкой и ДРАМом, то как вариант еще, это неисправна PWB-плата.

Где она находится?
Бункер который сборку я его почистил, он пустой, да и не сказать что был забит.
Что может быть с драмом?

Аватара пользователя

pc-porta

Сообщения: 879
Стаж: 1 год 9 месяцев
Благодарил (а): 20 раз
Поблагодарили: 125 раз

Репутация:

Kyocera Ecosys P3150dn

Сообщение

pc-porta »

Картинка не грузилась ….. вот и нету.
это ошибка инициализации блока DK-3150. Может контакт какой обломился на колодке ? или мусор какой в ней (та часть — которая в МФУ стоит) затёрся ?

Yuzorg98

Сообщения: 29
Стаж: 1 год 1 месяц

Kyocera Ecosys P3150dn

Сообщение

Yuzorg98 »

pc-porta писал(а): ↑03 апр 2023, 15:49
Картинка не грузилась ….. вот и нету.
это ошибка инициализации блока DK-3150. Может контакт какой обломился на колодке ? или мусор какой в ней (та часть — которая в МФУ стоит) затёрся ?

Изображение
вроде всё целое
грязи никакой нет

Отправлено спустя 14 минут 31 секунду:

стронций писал(а): ↑03 апр 2023, 15:50
Плата PWB находиться, если смотреть спереди, по правую руку за пластиком.

Нашёл, вставил аналогичную плату, но там ошибка 6120, и она же вылезла на этом принтере
Перепрошивка его поможет? С ошибкой 7900?

Аватара пользователя

стронций

Сообщения: 417
Стаж: 1 год 9 месяцев
Благодарил (а): 13 раз
Поблагодарили: 43 раза

Репутация:

Kyocera Ecosys P3150dn

Сообщение

стронций »

Прошить в принципе можно, хуже то не будет. Надо заказать свежую версию прошивки и смотреть фаил-блокнот «History» который идет, почти, со всеми прошивками. Там можно уточнить все об исправлениях ошибок, и каких конкретно ошибок.
Ну я что то сомневаюсь что прошивка поможет.

Аватара пользователя

стронций

Сообщения: 417
Стаж: 1 год 9 месяцев
Благодарил (а): 13 раз
Поблагодарили: 43 раза

Репутация:

Kyocera Ecosys P3150dn

Сообщение

стронций »

Если печная ошибка возникла то надо печку первым делом вскрыть и осмотреть. Вероятность что придется менять блок печки целиком 100%.
Как я и писал ранее если и отремонтировать печку, то есть подложить кусочек термопленки туда то и туда то, то все чудным образом заработает… Ну заработать то заработает, но появиться другая проблема, это уже проверено как минимум на 3-х FK-3130(3300).

Yuzorg98

Сообщения: 29
Стаж: 1 год 1 месяц

Kyocera Ecosys P3150dn

Сообщение

Yuzorg98 »

стронций писал(а): ↑03 апр 2023, 16:38
Если печная ошибка возникла то надо печку первым делом вскрыть и осмотреть. Вероятность что придется менять блок печки целиком 100%.
Как я и писал ранее если и отремонтировать печку, то есть подложить кусочек термопленки туда то и туда то, то все чудным образом заработает… Ну заработать то заработает, но появиться другая проблема, это уже проверено как минимум на 3-х FK-3130(3300).

Прошивка не помогла
Так же ошибка 7900

Аватара пользователя

pc-porta

Сообщения: 879
Стаж: 1 год 9 месяцев
Благодарил (а): 20 раз
Поблагодарили: 125 раз

Репутация:

Kyocera Ecosys P3150dn

Сообщение

pc-porta »

ну — я тоже в сомнении …. но — факт : ошибки 7900 — это ошибка инициализации блока DK от 3100 до 3190
если есть желание — соберите франкенштейна : перекиньте плату PWB и термистр в печке

Последний раз редактировалось pc-porta 03 апр 2023, 17:54, всего редактировалось 1 раз.

Yuzorg98

Сообщения: 29
Стаж: 1 год 1 месяц

Kyocera Ecosys P3150dn

Сообщение

Yuzorg98 »

pc-porta писал(а): ↑03 апр 2023, 17:51
ну — я тоже в сомнении …. но — факт : ошибки 7900 — это ошибка инициализации блока DK от 3100 до 3190

Гугл на эту тему мне толком ничего говорил, видать я один такой с этой ошибкой

Аватара пользователя

dviz

Сообщения: 238
Стаж: 1 год 9 месяцев
Откуда: Ярославль
Благодарил (а): 21 раз
Поблагодарили: 29 раз

Репутация:

Kyocera Ecosys P3150dn

Сообщение

dviz »

7900 — это либо плохой контакт с платой в драм-юните либо проблема с микрухой eeprom в на этой плате. Без драма аппарат естесствено будет выдавать эту ошибку.
Если показывает замятие — решайте проблему с замятием, а не с драмом.

  • 6 Ответы
    855 Просмотры
    Последнее сообщение

    Аватара пользователя


  • 2 Ответы
    556 Просмотры
    Последнее сообщение

    Аватара пользователя


  • 13 Ответы
    2867 Просмотры
    Последнее сообщение

    Я поленился установить аватар


  • 6 Ответы
    3455 Просмотры
    Последнее сообщение

    Аватара пользователя


  • 3 Ответы
    888 Просмотры
    Последнее сообщение

    Аватара пользователя


Понравилась статья? Поделить с друзьями:
  • Freelander 2 код ошибки p0102
  • Fs 4200 ошибка 6000
  • Fpt bios ошибка 201
  • Forza horizon 4 код ошибки 1000
  • Freebsd посмотреть ошибки на интерфейсе